DEVIreg-530

DEVIreg-530
7. Controls
Data
DEVIreg™ Sheet
DEVIreg™ 530
The DEVIreg™ 530 is a simple electronic thermostat with a 2-pole switch, using a floor
sensor (wire) to measure and control the desired floor temperature. It can be either flushmounted or surface-mounted.
The thermostat has a dial for adjusting the temperature setting with a scale from
to 6.
Furthermore, the thermostat has an LED indicating the current mode (heating, standby or
fault).
Type
Benefits:
Value
Operation voltage
• 2-pole safety breaker
Standby power consumption
• Low standby consumption
• Sensor failure monitoring
Relay:
Resistive load
Inductive load
• LED indication for fault
Sensing unit
• Frost protection
Hysteresis
220 V- 240V~ 50/60 Hz
max. 0.25 W
Max 15A / 3450W @ 230V
Cos Φ = 0.3 max. 1A
NTC 15 kOhm at 25° C
± 0.4° C
Ambient temperature
Standard compliance:
Frost protection
• EN/IEC 60730-1 (general) and
EN/IEC 60730-2-9 (thermostat)
Cable specification max
5° C -
Temperature range
k H B d
Approvals:
-10° C. to +30° C
5-45°C with floor sensor only
1 x 4 mm2 or 2 x 2,5 mm2
Ball pressure test temperature
75° C
Pollution degree
2 (domestic use)
Controller type
1C
Storage temperature
-20° C to +65°C
IP class
31
Protection class
Class II -
Dimensions (H/W/D)
85 mm x 85 mm x 36 mm
Weight
90 g
Types
Product name
Code
No.
140F1030
Name
DEVIreg™ 530
EAN no.
Description
With floor sensor and ELKO frame
5703466208991
Manual
Floor
temperature
DEVIreg™ 530 Flush Mounted
With floor
sensor
and
ELJO frame sensing thermostat
DEVIreg™530
(Supplied for fitting to a Euro Flush Box)
140F1032
DEVIreg™ 530
DEVIreg™ 530
5703466209011
10 pcs. pack with floor sensor and JUSSI frame
5703466152829
10 pcs. pack with floor sensor and ELKO frame
5703466159248
Adapter Plate to enable fitting to a Standard NZ Flush Box
08-1547
Euro Box (Metal)
Euro Flush box for wall mounting thermostat as supplied
08-1548
Euro Box
(Plastic)weEuro
Flush
boxEuro
for wallbox
mounting
thermostat as supplied
Should
have
the
accessory?
DEVIreg™ 530
Euro Box
93
Adapter Plate
19150354
NZ flush box Adapter Plate
N
N
LOAD
L
L
LOAD
Line Diagram
Mains
Max. Load
220-240V~ 15 (1) A
Metal
5703466209004
With floor sensor and JUSSI frame
IP31
-10T30
Plastic
D530
DEVI Heating Systems Ltd (H/O)
36B Sonter Road, Wigram 8042
PO Box 8582 Riccarton, Christchurch 8440
Produced by Danfoss © 07/2015
Ph 03
378 0070 Fx 03 378 0067
NTC
Sensor
140F1031
01-140F1030
Accessory
19150352
08-AP
Type
VDIIH102
L
-5°C
Accessories and spare parts on page
Item no.
By connecting an external timer to the terminal
marked by a moon symbol (and by using for example
the same phase as for the mains power supply), the
thermostat can be set to reduce the temperature by
5ºC during specified periods.
The screen of the heating cable must be connected to
the earth conductor of the power supply cable by using a separate connector.
DEVI Heating Systems Ltd
6C Dallan Place, Rosedale 0632
PO Box 101-274 North Shore, Auckland 0745
79
Ph 09 415 7250 Fx 09 415 7512
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising