DMP 128 • Setup Guide
This guide provides basic instructions for an experienced technician to install
the DMP 128 ProDSP™ Digital Matrix Processor. For additional information
and specifications, see the DMP 128 product page at www.extron.com.
Disconnect Power and Mount the DMP 128
Disconnect power to the DMP 128 and turn off all devices that will be connected to it. The DMP 128 is housed in a full rack width,
8.5 inch deep, 1U high metal enclosure that can sit on a table with the provided rubber feet or can be rack mounted. Select a
suitable mounting location, then choose an appropriate mounting option.
Make all external device connections before applying power.
DMP 128 C P AT
3
2
3
9
4
4
9
10
10
2
3
MIC
+48V
+ 48V
4
1
2
3
4
5 5
66
77
8
5
6
5
6
7
7
11
8
8
11
12
LINE
PHONE
PHONE
12
2
1
DMP 128 C P AT
LINE
MIC +48V
1
DMP 128 C P AT
1
O
U
T
P
U
T
S
2
3
3
4
1 2 3 4 5 G
1 2 3 4
5
5
6
6
7
7
8
8
5
11 12 13 14 15
6 7 8 9 10 G
6 7 8
9 10
1
16 17 18 19 20
11 12 13 14 15 G
50/60 HZ
a
DIGITAL I/O
4
AT
2
1
DIGITAL I/O
1
2
REMOTE
50/60 Hz
MIC/LINE INPUTS
MIC/LINE INPUTS
100-240 ~ 0.6A
OUTPUTS
100-240V ~ 0.6A MAX
RS-232
16 17 18 19 20 G
1
2
3
EXP
c
d
k
e
f
4
RESET
RESET
Tx Rx G
LAN
EXP
Tx Rx
b
3
4
LAN
RS-232
å
j
h ç i
Connections
a AC Power — IEC power connector 100 – 240 VAC, 50 – 60 Hz.
b Phantom power indicators — Green LEDs light when + 48 V phantom power is placed on the corresponding input. Phantom
power voltage is not adjustable and is available only on inputs 1 – 8.
c Mic/Line 1-8 input connectors — Connect up to eight balanced or
unbalanced microphone or mono line level devices using 3-pole 3.5 mm
captive screw connectors. Phantom power is available to any of these
inputs. Wire as shown at right.
Audio Input Wiring
Tip
Ring
Sleeve
Tip
Sleeve
10
Unbalanced Input
Balanced Input
0-2
40
V~
--A
MA
d Mic/Line 9-12 input connectors — Connect up to four balanced or unbalanced
mono microphone or line level, or two stereo devices to these 6-pole 3.5 mm
captive screw connectors (see Audio Input Wiring at right).
50
/60
Hz
MIC/LINE INPUTS
X
1
MIC
2
1
+4
8V
2
3
4
5
6
NOTES:
8
Sleeve Tip
Ring
Sleeve
Balanced
Audio Input Wiring
7
Tip
Audio Output
Sleeve Wiring
• When using the 5-pole CSR adapter, connect it so that its far left
Input
plug inserts into the far left jack of the 6-pole input connector (see
Balanced Output
example at right).
or unbalanced mono line level or four stereo outputs to these
6-pole 3.5 mm captive screw connectors. Wire as shown at
right. In addition 5- and 6-pole connectors can be used (see
Audio Output Wiring, right).
DO NOT
Connect Here
4
6
• Balanced or unbalanced stereo devices can be connected to the
Tip
6-pole connectors.
Ring
e Mono output connectors — Connect up to eight balanced
3
5
7
Tip
NO Ground Here
Sleeve
Unbalanced
5-pole CSR
9
10
8
DM
P1
28
11
Input
12
Unbalanced Output
Audio Output Wiring
Tip
Ring
Sleeve
Balanced Output
Tip
NO Ground Here
Sleeve
Unbalanced Output
ATTENTION:
For unbalanced audio outputs, connect
the sleeves to the ground contact.
DO NOT connect the sleeves to the negative (-) contacts.
1
DMP 128 • Setup Guide (Continued)
f Digital I/O connectors — Connect up to four 6-pole 3.5 mm captive screw connectors.
3"
(5
16
Each
connector provides five configurable digital input or output ports allowing connection of up to
twenty devices such as motion detectors, alarms, lights, LEDs, buttons, photo (light) sensors,
temperature sensors, and more.
mm) MAX.
Do not tin the wires!
1
2
3
4
5
G
Digital I/O ports can monitor or drive TTL level digital signals. The inputs are configured to
operate in one of two modes: digital input or digital output. In output mode, the device sources
up to 250 mA at +5 V. In input mode, voltages greater than 1 V indicate a logic ‘high’ signal while
voltages less than 1 V indicate a logic 'low'.
Digital I/O Wiring
Digital I/O ports are tied to a common ground (one common ground for each 6-pole connector).
g Connect a control system — There are three options to connect a control system to the DMP 128: LAN, RS‑232, and USB
(front panel only). Extron recommends using the LAN port for configuration and remote control of the DMP 128.
RS-232 — Connect the host RS-232 cable to the rear panel of the switcher (å) using the
provided 3-pole captive screw connector for bi-directional RS-232 (±5 V) serial control. The
default baud rate is 38400. Use the wiring diagram at right.
Do not tin
(the ).wires!
The
LAN — Using a standard Ethernet cable, connect to a network via the LAN port ç
table at right shows the default network settings. The control system and DMP 128 must be
connected on the same network.
NOTE: To connect the DMP 128 directly to a computer Ethernet port, use a
crossover Ethernet cable.
RS-232
Device
Transmit (Tx)
Receive (Rx)
Ground ( G )
Tx Rx G
Bidirectional
Transmit (Tx)
Receive (Rx)
Ground ( G )
IP Address: 192.168.254.254
Subnet Mask: 255.255.0.0
Default Gateway: 0.0.0.0
DHCP: OFF
USB — Connect the host USB port to the front panel configuration port, (not shown), using a
USB A to mini-B cable. The USB connection is used only for configuration. Use the RS-232 or LAN port for remote control of
the DMP 128.
h EXP port connector — One RJ-45 jack for digital audio connection to an additional DMP 128 using the Extron proprietary
protocol. Use the included one foot long shielded CAT 6 cable to connect two DMP 128s to form a larger matrix system. The
expansion bus supports 16 bi-directional channels of audio; eight assignable channels that are mixed from any of the input
and virtual paths, and eight channels directly connected to the virtual return path outputs. See the DMP 128 User Guide for
operation details.
i Reset button and LED indicator — The reset button returns the DMP 128 to different tiers of default states and places the
unit into an event recording mode for troubleshooting. The LED flashes to signify the different tiers
(see “DMP 128 Hardware Reset Modes” in the DMP 128 User Guide).
j AT ports (AT models only) — Four RJ-45 jacks form a 4-port Gigabit switch that interfaces with the AT bus. The
AT expansion bus uses the Dante™ protocol for digital media networking allowing connection of multiple DMP 128 AT
models to form a larger matrix. See the DMP 128 User Guide for operation details.
NOTE: The Dante Controller software is required for configuration of the AT expansion bus (see Dante Controller
Software Installation (AT models only) on the next page).
k Telephone ports (P models only) — Two RJ-11 jacks for incoming line (LINE) and telephone (PHONE) connection.
The telephone interface follows all applicable US standards and international standards for select countries. A phone dialer is
available in the DSP Configurator control software to assist with setup and testing.
When all connections have been made, power up the input and output devices, then apply power to the DMP 128.
DSP Configurator Software Installation
There are no hardware controls for the DMP 128. All configuration and control is done using DSP Configurator. Install
DSP Configurator on a PC running Microsoft® Windows® 2000 or later. For full details about computer requirements, see the
DSP 128 User Guide on the Extron website at www.extron.com.
Insert the provided disc into the computer disc drive. If the setup program does not start automatically, run Launch.exe from the
disc. When the program opens, select the Software tab, locate the DSP Configurator program, and click Install.
DSP Configurator can also be downloaded from the Extron website home page by clicking on the Download tab, selecting
Software from the list at the left, and locating the program. Click on Install and follow the on‑screen instructions.
NOTE: On the first installation of DSP Configurator, the USB driver loads automatically. Follow the on-screen instructions.
Once the USB driver has loaded, DSP Configurator continues to load.
By default, the program installs in C:\Program Files\Extron\DSP Configurator and an icon is placed on the desktop.
2
Product Category
DMP 128 Configuration
When power is connected to the DSP 128, an audio source, a power amplifier, and speakers, it produces an audio output that can
easily be tailored to the listening environment. When a different configuration is required, change it using the DSP Configurator
setup and control software.
To Configure the DMP 128:
1. Ensure the control computer is connected to the
Ethernet port (recommended), RS-232 port, or front
panel USB Config port of the DSP 128 (see “Item 7”
on page 2).
2. Start the DMP Configurator software. Select the
DMP 128 model corresponding to your model
(DMP 128 C P shown at right). The main DMP 128
screen opens.
3. The program starts in emulate mode.
a.
To create a configuration offline and upload (push)
those changes to the DMP 128 at a later time,
remain in emulate mode.
b. To push a configuration to the device, pull
a configuration from the device, or to make
immediate changes to the configuration or
operation, select Live mode.
NOTE: When live mode is selected, a connection
dialog box appears. Select the desired
connection and follow the on‑screen prompts.
The connection can be changed from the main
menu by selecting Tools>Connect to Device,
or by pressing <F6>.
For more information about live and emulate modes, see the DMP 128 User Guide.
The main screen provides access to all the features of the DMP 128. Full details about using the DSP 128 software can be
found in the DMP 128 User Guide on the Extron website at www.extron.com or in the help file for the program.
Dante Controller Software Installation (AT models only)
The DMP 128 AT uses Dante Controller for Windows to select and route inputs and outputs for all connected DMP 128 AT
models.
Download and install the latest version of Dante Controller for Windows from the included software DVD or from the
Dante Controller product page at www.extron.com.
3
Dante Network Audio Setup
The following is the recommended procedure for configuring DMP 128 AT models on a Dante network.
NOTE: A connection to both the Dante (AT) Ethernet switch and the DMP 128 LAN port is required to follow this setup
procedure. If the control computer has only one Ethernet port, connect it to a rear panel AT port (item j on page 2). Then
connect a short CAT 5 cable from the LAN port (item ç on page 2) to an unused AT port (item j on page 2). Alternately
use an Ethernet switch to connect the control computer to both the LAN and AT ports.
1. Connect the control computer to an AT (Dante) port on the DMP 128. Also connect the control computer to the DMP 128 LAN
port (see Note above).
2. Start DSP Configurator in Live mode (see steps 1, 2, and 3b of DMP 128 Configuration on the previous page).
3. From the DSP Configurator toolbar, select Tools>Device Settings.
4. In the Unit Name: field, enter a descriptive name for the DMP 128 (typically the device name and location) that enables it to
be easily identified on the network.
5. Click Apply, then close the dialog box.
6. From the DSP Configurator toolbar, select Network Audio Control. If Dante Controller does not launch, see the Dante
Controller Software Installation (AT models only) section on the previous page.
7. From Dante Controller toolbar, select Device>Device View.
8. Choose the Dante device. The DMP 128 appears as DMP128, plus the last six digits of the Dante MAC address.
NOTE: Connect DMP 128 units to the Dante network one at a time to easily identify the units. To confirm the proper
device is configured, compare the Dante MAC address printed on the rear of the unit with the MAC address in the
Device View..
9. Select the Device Config tab in Dante Controller.
10. Rename the device to match the DSP 128 name given in DSP Configurator (see step 4 above), then press <Enter>.
11. Select Yes to confirm the new name.
12. To connect additional DMP 128s, repeat this procedure with the next device.
See the Dante Controller section in the DMP 128 User Guide for operation of the controller software.
Telephone Ports (DMP 128 C P and DMP 128 C P AT only)
The DMP 128 provides a telephone interface with separate input and output signal processing paths (labeled “Telephone Rx”
and “Telephone Tx” on the DSP Configurator main screen on the previous page). The country code must be entered before
attaching the DMP 128 to a phone system.
To set or change the country code of a phone model:
1. Follow Steps 1 and 2 from To Configure the DMP 128 on the previous page, then select
Live in the Mode box.
NOTE: The device settings dialog can be accessed only in Live mode.
2. From the main DSP Configurator menu , select Tools>Device Settings.
3. From the Device Settings dialog, select the Phone Settings tab (see diagram at
right).
4. If the correct country code is not listed under Selected Country:, click Change
Phone’s Country Code, then select the correct country code for your region from the
dropdown list.
5. Click Apply, then close the dialog box.
See the DMP 128 User Guide for operating details of the phone modem.
Extron Headquarters
Extron Europe
Extron Asia
Extron Japan
Extron China
Extron Middle East
Extron Korea
Extron India
+800.633.9876 Inside USA/Canada Only
+800.3987.6673
Inside Europe Only
+65.6383.4400
+65.6383.4664 FAX
+81.3.3511.7655
+81.3.3511.7656 FAX
+86.21.3760.1568
+86.21.3760.1566 FAX
+971.4.299.1800
+971.4.299.1880 FAX
+82.2.3444.1571
+82.2.3444.1575 FAX
1800.3070.3777
(Inside India Only)
Extron USA - West
Extron USA - East
+1.714.491.1500+1.919.850.1000
+1.714.491.1517 FAX
+1.919.850.1001 FAX
4
+31.33.453.4040
+31.33.453.4050 FAX
+91.80.3055.3777
+91.80.3055.3737 FAX
© 2013 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com
68-2036-50
Rev. B 08 13
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising