Yale HSA3400, HSA6010, HSA3020, HSA6020, HSA3060, HSA6021, HSA3010, HSA6050, HSA3050, HSA6060, HSA3045, HSA6080, HSA6090, HSA3080, HSA6091, HSA3030, HSA3070 alarm system User Manual
Below you will find brief information for alarm system HSA3400, alarm system HSA6010, alarm system HSA3020, alarm system HSA6020, alarm system HSA3060, alarm system HSA6021, alarm system HSA3010, alarm system HSA6050, alarm system HSA3050. The Yale wireless alarm system is designed to protect your home when you're away. The system includes a siren, PIR sensors, door/window contacts, and a remote control keypad. You can choose to arm the system with a 20-second exit delay, allowing time to leave the home, or with an instant arm, which is ideal for when you’re already outside the home. The system has a 20-second entry delay, so you can disarm the system without triggering the alarm. The system also includes a tamper-proof feature that will trigger the alarm if anyone attempts to tamper with the system.
Advertisement
Advertisement
Siren-Based Alarm System
Installation · Programming · Operating
Keep this manual safe for reference and future maintenance
Introduction
General System Overview
Thank you for choosing the Yale Wireless Security
Alarm System. This simple to install system has been designed with the user in mind.
The siren has a sounder and strobe LEDs to attract attention.
Number of devices
You can install up to 20 devices in the system.
As well as extra door/window contacts, PIRs and keypad remote controls, you can add smoke detectors, keyfob remote controls and help buttons.
Long battery life
The system has a typical battery life of 2 years or more before they need changing. Regular testing and battery changes (when notified by the system) will ensure reliability and peace of mind. Please note that alkaline batteries and the correct type of coin cells must be used as replacements.
Tamper proof system
Each part of the system is ‘tamper’ protected. Any unauthorised tampering with the system will result in an alarm. This feature can be turned off by the user when a battery change is required.
Entry/Exit feature (for System with remote keypad)
The system has a 20 second entry/exit time. This feature allows you time to leave the home when arming the system. Upon entering, the feature allows time to disarm the system without causing an alarm.
Take care of your safety
Display extreme caution when using ladders or steps, please follow manufacturer instructions. Be careful when using hand and power tools and follow the manufacturers’ guidelines when using them.
Take care that the correct tools are used. Wear goggles or protective clothing where required.
The external Siren is extremely loud, please ensure you replace the cover and retreat to a safe distance before testing.
Contents
Contents
1 Location planning
2 Unpacking the system
3 Programming the system
4 Mounting alarm devices
5 Using the system
Adding accessories
Changing the batteries
Specifications
Trouble shooting
Recommended Installation Sequence
9-10
11
12
14
15
2
3-4
5
6-8
We recommend you follow the easy start sequence, headings numbered 1-5.
Information and illustrations are subject to change within this document. Yale reserves the right to alter the specification and product design at anytime without notice. Yale® is a registered trademark. © 2010 ASSA ABLOY. All rights reserved.
1
Location planning
Work out the best places to locate the devices for maximum protection. Having chosen the locations do not mount at this stage.
Operating range
All devices must be within 30 metres of the siren unit and must not be mounted on or near large metal objects. Avoid obvious sources of electrical interference such as fridges and microwave ovens.
Siren
Choose a position on an external wall where the siren would be most prominent. Mount as high as possible, out of easy reach. (Round shaped siren shown)
Tamper switches
When mounting devices ensure that any tamper switches close fully. On uneven surfaces it may be necessary to place packing behind the switch for reliable operation.
Help button accessory
The help button provides extra protection for you and your family. When help is needed the button can activate your alarm immediately - even when the system is disarmed.
• Mount on bedroom wall or by the front door
• Not clearly visible to an intruder
• Easily accessible
• Out of reach of children
Smoke detector
• Mount in the middle of the ceiling at the top of a stairwell, or on the centre of hallway ceilings where smoke would most likely be detected.
• Do not mount in corners or above cooking appliances and heaters.
• Install additional detectors if there are closed doors preventing smoke from reaching detectors.
Door/Window contacts
Use one door/window contact on a door that is used as the main point of entry and exit, usually your front door. The other door/window contact can be used to protect another entry point such as a rear door.
• Mount as high as possible.
• Do not aim a PIR at this door or window.
Yale
R
Keyfob remote control accessory
Can be used outside the premises and kept on your keyring.
Yale
2
PIR movement detectors
• Mount in a position such that an intruder would normally move across a PIRs field of view.
• Height should be between 1.7 and 2.3 metres above floor level.
• Location in a corner will ensure wider room coverage.
• Do not mount a PIR where its field of view will be obstructed e.g. by curtains, ornaments etc.
• Do not point directly at sources of heat e.g. fires or boilers, and do not position directly above radiators.
• Avoid mounting a PIR directly facing a window.
• Do not point a PIR at a door protected by a door/window contact.
Keypad remote control
• The keypad should be sited next to the main point of entry/ exit so that the system can be disarmed/armed within 20 seconds of entering/leaving the premises.
• Ensure that the keypad is not visible from the outside of the premises.
• Mount at chest height for ease of use.
• Designed for indoor use only.
Extend the system
Extend the system in the future to increase your security or as your needs change.
For example, add extra PIR detectors in bedrooms and extra door/window contacts.
2
Unpack all the parts on a table top
The easiest way to get to know the system and get it up and running quickly is to get all the devices and accessories programmed on a table top before locating and mounting them.
Yale
R
Y e
R
Fixing screws X 4
Internal cover screws X 4
Power switch
Learn button
Programming switch
OFF
ON
Battery
Compartment
4 X D cells
Siren
The siren comes in two shapes, square shaped and round depending on the kit purchased. The operation and programming of the sirens are identical, only the case is different.
WARNING
The siren is very loud, be prepared! Take care not to activate the siren tamper switch unnecessarily.
1 Remove the cover by unscrewing the single screw located on the lid.
2 Square siren only: remove the left hand cover (not battery compartment).
3 Move the programming switches to Master On (switch 4) and Clear
On (switch 1).
Clear
4 Switch the power switch to on
(The 3 strobe LEDs will now flash side to side with one short beep.)
5 Move the Clear switch to the Off position.
PIR movement detectors
1 Pull out the plastic pull tab on the back of the PIR.
This will activate the batteries.
(A red light can be seen flashing through the lens. This will last for 30 seconds indicating the component’s initiation. )
Status
LED
Learn/Test
Button
Cover screw
3
4
Keypad remote control
1 Pull out the plastic battery saver tab at the back of the remote keypad. This will activate the batteries.
Keypad remote control
Keypad remote control
while components initialise.
Arm
Y ale
6
Panic
A
Remove the cover and insert the 3 AAA alkaline
Remove the cover and insert the 3 AAA alkaline batteries as shown. The ‘Tx’ LED will flash briefly
Please note, the Home button on the operating panel and the jumper switch inside (do not move) panel and the jumper switch inside (do not move) have no function on this model.
Home
Arm
Keyfob remote control accessory
1 Open the battery compartment using a coin
Keyfob remote control accessory
Keyfob remote control accessory
Slide off the battery cover, insert the
23A/MN21 battery as shown, and replace battery cover. Switch to ‘on’.
battery cover. Switch to ‘on’.
On/Off switch
On/Off switch
Yale
R
Door/window contacts
Jumper
1 Pull out the plastic pull tab found on the side of the main unit. This will activate the battery.
Tamper switch
Tamper switch
Gap no more than 8mm
Door/window contacts
Door/window contacts
1 Remove the cover of each door/window contact
1 Remove the cover of each door/window contact
2 Insert two AAA batteries into each detector as
2 Insert two AAA batteries into each detector as shown. The indicator LED will flash briefly.
Extension terminals
Extension terminals
Magnet
Tamper
Tamper switch
Jumper switch switch
Sensor
Battery saver tab
Learn/Test button button
Magnet
Magnet
Smoke detector accessory
1 Remove the cover and insert the four AAA batteries as shown
Smoke detector accessory
Smoke detector accessory
calibration mode for 10 minutes. It will resume
Remove the cover and insert the four AAA batteries as shown.
Learn/Test button
Learn/Test button
Help button accessory
Help button accessory
Remove the cover by loosening the fixing
Remove the cover by loosening the fixing shown. Please ensure you observe battery shown. Please ensure you observe battery polarity.
7
7
3
Programming the Siren-based system
(without control panel)
The siren is the heart of the system. All components must be recognised by the siren.
1
Entering Learn mode:
• Press and hold
Siren learn button
for 1 second.
(A short beep will follow with the outside LEDs flashing once.)
i
System is now in learning mode for 3 minutes.
Proceed to the following steps to add in additional devices (20 devices maximum) within this time period.
If device learning takes more than 3 minutes and the learn mode expires, the siren learn button will need to be pressed again to add more devices.
3a
Exiting Learn mode:
•
Press the Siren Learn button to exit the learn mode
•
The PIR and Door Contact may trigger the Siren at this point.
(Do not turn the siren power off.)
3b
Disarming Siren:
•
Press disarm followed by 0000.
(The siren will beep and flash twice.)
2
Adding devices:
i
When any device is learnt-in, the siren will beep once and the outside LEDs will flash once in acknowledgement.
Remember to press any buttons and keys firmly for 1 second to send a learn-in radio signal.
4
Adjusting Alarm ringing duration:
• Dip switch 3 determines the alarm ringing duration length. Switch left for 4 minutes or right for 10 minutes (default) siren duration.
5
Enable/disable interference detection:
• Set Dip switch 2 for interference detection. Switch left to enable and right to disable (default).
Y ale
R
1 2 3
4 5 6
7 8
9
0
PRESS
PRESS
Battery cover
Coin slot
Locked
Unlocked
PRESS
PRESS
Yale
PRESS i
This unit is equipped with the latest type of radio receiver using AM radio technology. If the system is armed any criminal attempt to interfere detector transmissions will trigger an alarm.
If the alarm is frequently triggered by interference there may be high levels of unusual radio signals in your area. Some kinds of electronic equipment can generate this kind of radio interference.
In the unlikely event of you experiencing problems with interference, it is recommended that you switch interference detection off.
Programming is now finished and the system is ready to be installed.
Keypad
(All keys should be pressed in quick succession.)
1 Press
Panic button A
and enter pincode
(please note that the default pincode is 0000).
(The LED will now be flashing. System is now in setting mode)
2 Press
Panic button A
and enter
8
(The keypad will confirm with two fast flashes that it is in “Siren as master” mode.)
3 Press
Panic button A
then
1
to send learn-in signal.
4 Press Panic button A then 2. The press disarm twice to quit.
(The siren will beep in acknowledgment).
(The keypad LED will now stop flashing. If not, press “disarm” twice again)
5
4
Mounting alarm devices
Before mounting the keypad and siren ensure that the system tamper is disabled as described below.
Disabling the system tamper
i
Before mounting it is important to disable the system tamper to avoid the siren sounding an alarm.
Using the Keypad:
• Press
Panic button A
and enter pincode
(factory default is 0000) to enter test mode, press
Panic button A
then
2
to send “Tamper Off” signal,
Then press disarm twice to quit. (The keypad led will now stop flashing if not press disarm twice again.
The siren will beep in acknowledgement.)
Using the Keyfob:
• Press and hold down
Arm
and
Home
buttons for 5 seconds.
(The siren will beep in acknowledgement.)
i
The tamper function is now disabled for one hour.
If more time is required, simply repeat the above step.
Mounting the siren
Ensure the tamper switch is fully depressed when the siren is mounted. If there is a gap, pack with a suitable spacing material.
6
Spring compressed firmly against wall
Round
Siren
Base
Wall
Wall
Spring Guide
Plunger must be pressed in fully against wall
1 Using the large screws and wall plugs provided, mount on the desired wall through the 4 mounting holes.
2 Fix the siren cover with the securing screw.
Testing whether the siren is fitted correctly:
1 Press
Arm
with the Keypad/Keyfob.
2 If there are 5 short beeps when armed, the tamper switch is NOT fully depressed and will need to be adjusted. i
Before you make the adjustment:
• Disarm your system using your keyfob (Press disarm) or keypad (Press disarm followed by the pincode).
• Disable the system tamper as described on the left.
• If there is a gap between the wall and the tamper switch mechanism pack with a suitable spacing material.
• Once finished repeat the step 1 and 2 above.
3 If there is one short beep and flash when armed, the siren is mounted correctly and the siren installation is complete. Disarm the system and disable the tamper as described in the information box above.
Mounting other devices
Find a location where the device is to be mounted, see section “Location Planning” for suggestions.
i
Before proceeding to mount the devices physically, it is useful to check that it is not out of radio range by doing a simple range test. Please ensure the system tamper is disabled.
• Keypad: Hold the keypad in the desired
location and arm and disarm the system.
(The siren will beep as confirmation.)
• Help button: To prevent an alarm being
triggered, put the siren into learn mode first
(see page 5, section 1). Hold the device in the
desired location and press the emergency
button.
(The siren should respond with a single beep.)
• All other devices: Hold the device in the
desired location and press the learn/test
button.
(The siren should respond with a single beep.)
When you are satisfied that the devices work in your chosen locations, proceed with the installation as described in the next page.
If the siren does not respond, the location may be out of range, try alternative locations until reliable radio contact is obtained.
Mounting the Keypad:
1 Drill holes into the wall using the fixing slots as a template.
2 Fit wall plugs into the wall and fix cradle with the screws provided.
Fixing Slots X 2
Keypad
Cradle Open
Mounting the door/window contact
Frame
Door/Window
3 Slide the keypad into the cradle
4 Close the cradle cover so the logo is facing you
Mounting the PIR
1 Open the PIR by loosening the bottom screw.
Knock out the relevant holes on the base where the plastic is thinner. The center two knockout holes are for flat wall mounting while the 4 side holes are for corner mounting.
Wall fixing knockouts X 2
Corner fixing knockouts X 4
2 Drill holes into the wall using the knockout holes on the base as a template.
3 Fit wall plugs and secure the PIR base with the screws provided.
4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete.
i
The PIRs have a built-in sleep timer to save battery power. If there is no movement in front of the PIRs for 1 minute, the PIRs will become
‘ready to signal’ and movement will now be reported. The PIRs will sleep for 1 minute after reporting.
Any movement detected in sleep time will not be reported and will extend the sleep period by a further 1 minute.
Magnet
Sensor
Gap approx 10mm than 8mm
1 Find a location where the door/window contact is to be mounted. It should be mounted between the door/window frame and the door/window as shown at the top of the opening. The magnet is to go on the door/window while the sensor is to be placed on the frame. Windows can be protected in a similar way to doors. Make sure the tamper switch spring is fully depressed.
i
The gap between the magnet and sensor should be approximately 10mm when closed (depending upon the actual environment).
Simple test to see whether the magnet is in range of the sensor: hold the magnet and sensor in place and then pull them apart. If the sensor LED lights up it implies the two items are within range.
-Mounting using adhesive pads
1 Clean the mounting surface with a suitable degreaser agent.
2 Remove the protective film from one side of the adhesive pad and apply to the back of the sensor and magnet
3 Remove the remaining protective film and firmly press into place.
4 Test sensor by pressing the test button and opening and closing the door/window. The LED should light when the door/window is opened.
Installation is complete.
7
8
-Mounting using screws and wall plugs
1 Loosen the bottom screw and open the door/ window contact.
Knockouts
2 Knock out the holes on the base as shown.
3 Drill holes into the mounting surface using the holes in the knockouts on the base as template.
4 Fit wall plugs (if required) and secure with the screws provided.
5 Fit sensor back together and tighten screw.
6 Test sensor by pressing the test button and opening and closing the door/window. The LED should light when the door/window is opened.
Installation is complete.
Mounting the Help button
1 Break through the knockouts (where the plastic is thinner).
2 Using the holes as a template, drill holes in the surface and insert wall plugs if fixing into plaster or brick. Screw the rear case to the wall.
3 Replace the cover and tighten the screw.
i
The tamper switch will automatically reactivate after one hour. Alternatively you can enable the tamper switch manually (optional).
See Page 10, Table 1 and Table 2 for manual tamper switch reactivation using Keypad or
Keyfob.
Mounting the Smoke Detector
1 The base has two mounting slots. Using the slots as a template, drill holes and insert the wall plugs if fixing to plaster. Screw the rear case to the ceiling using the screws provided.
2 Replace the cover.
5
Using the system
Arm and disarm the system and practice using it. Trigger the alarm by arming the system and opening protected doors/windows and walking past PIRs. Now’s the time to set your pin code and show the rest of the family how simple it is to use.
Arming the system
Keypad/Keyfob: Press arm
(The siren will beep and flash once. There will be no audible countdown.)
i
• Keypad will arm the system with a 20 seconds
exit period. All detectors will be ignored (except
for the tamper switches). The system can be
armed when inside the protected area of your
premises.
• Keyfob will arm the system instantly without a
20 second exit delay. Any detector activated afterwards will trigger an instant alarm. The system should be armed when outside the protected area of your premises.
Disarming the system
Keypad: Press disarm followed by your pincode.
Keyfob: Press disarm.
(The siren will beep and flash twice.)
i
• Keypad: If the system has been armed with a keypad there will be a 20 second entry period started when the first detector is activated
(usually a window/door contact on the main point of entry). During this entry period all detectors will be ignored. The siren will beep once when the first detector is triggered.
• If the system is not disarmed before the entry period expires, the alarm will be activated.
• The system does not have an audible countdown during the entry period.
• Keyfob: If the system has been armed with a keyfob there will be no 20 second entry period and any detector activation will give an instant alarm.
• The system should be disarmed from outside the protected area of your premises.
Stopping the Siren
Keypad: Press disarm followed by your pincode.
Keyfob: Press disarm.
(The siren will be silenced and then beep and flash twice.)
Changing your keypad PIN code
1 Enter setting mode: Press the Panic button A, followed by entering the current pincode (factory default code is 0000).
(The LED will now flash continuously.)
2 Press panic button B.
3 Enter new 4-digit pincode.
4 Press Arm button to confirm.
5 Exit setting mode: Press disarm twice to quit the changing code process. Or wait for 5 minutes for the keypad to quit test mode automatically.
(The LED will now stop flashing.)
i
• If the PIN code doesn’t change, repeat the above procedure quickly without gaps.
• The keypad will lock out for one minute after four failed attempts to enter the pincode.
Tamper alarm warning
If any device tamper switches are disturbed a tamper alarm will be activated with the siren sounding and the strobe flashing. The alarm can be silenced as described in “Stopping the Siren”. i
If there is a persistent siren tamper fault then a series of 5 pips and flashes will be given when the system is armed, then the siren should be checked for any mounting problems and if the siren lid is secure.
Previous alarm warning
Should there be an alarm that was triggered and expired (while the user was away), the siren will sound and flash for 3 seconds after disarming (user returning home).
* Warning: should this happen the intruder could still be in the premises.
My PIN code:
(write your pincode here so you don’t forget it)
9
Using the help button
Activate: Press and hold panic button for 2 seconds, the LED will light briefly and the siren will be activated.
Silence: press and hold panic button for 10 seconds, the LED will light briefly and the siren will be silenced.
i
Please note that silencing the alarm with the help button does not disarm the system. If the alarm is armed prior to activation, the system will re-arm after being silenced with the help button.
Using the smoke detector
The smoke detector will indicate a fire by sounding its built-in siren, lighting the LED and activating the external siren and strobe.
-Smoke detection
When smoke is detected the device will activate for a minimum of 10 seconds with a two tone alarm and flashing LED for a local fire alarm. The detector will also activate the external siren and strobe.
• Pressing the test button when in an alarm condition will silence the alarm for 10 minutes, it will automatically resume smoke detection again after this period.
• If the smoke density is still over the alarm threshold, then the smoke detector will remain in an alarm condition and it will repeat the local fire alarm and activate the external siren and strobe again.
10
-Testing
Smoke detector testing should be done on a regular monthly basis. Pressing the test button will make the LED flash, the audible sounder chime and will send a radio test signal to the siren when the button is released. If nothing happens after pressing the test button then change the batteries.
-Recalibration
The smoke detector might need recalibrating after time to ensure it is working at its optimum. This is done by pressing and holding in the test button until the LED flashes and it beeps after 10 seconds. The detector will then start its self-calibration routine.
Keypad Modes:
Table 1
Entering setting mode:
Press Panic button A followed by pincode
(factory default is 0000)
. You can now select different function.
(The LED on the keypad will start flahsing)
Function setting:
Press Panic button A , followed by one of the following number key:
1
Send learning/testing signal
2
Disable Siren tamper
3
Enable Siren tamper
4 Enter learn mode
(not suitable for first time set-up)
5
Exit learn mode
7 Keypad to work with control panel based sysem.
8 Keypad to work with siren based system.
Exiting setting mode:
Press disarm twice.
(The LED will now stop flashing. If not, press disarm twice again)
KeyFob Modes:
Table 2
•
Sending learn signal
Press any key except the emergency button.
•
Siren tamper (Enable)
Press and hold down Arm and emergency for 5 seconds.
•
Siren tamper (Disable)
Press and hold down Arm and Home for 5 seconds.
•
Learn mode (Enter)
Press and hold down Home and emergency for 5 seconds.
•
Learn mode (Exit)
Press and hold down disarm for 5 seconds.
Adding accessories
To provide additional protection you can add extra door/window contacts, PIRs, keyfob remote controls, keypad remote controls, help buttons and smoke detectors. These are available separately from your local stockist.
i
Adding devices for the first time
See section 3 (page 5) for first time system installation.
Adding devices to an already installed system
The installed system will be controlled by either a keyfob(s) or a keypad(s).
Keypad
1 Enter Setting mode: Press Panic button A followed by the pincode
(Indicated by a continuously flashing LED.)
2 Switch OFF system tamper: Press Panic button
A followed by 2
(The siren will beep in response.)
3 Enter learn mode: Press Panic button A followed by 4 .
(The siren will beep and flash in response.)
4 LEARNING: Press device learn/test buttons (see section 3, step 2) to trigger learning-in signals.
(The siren will beep and flash when each device is learnt in.)
5 Exit learn mode: When all the devices have been learnt in, press Panic button A and 5 to quit learn mode.
6 Switch ON system tamper: Press Panic button A and 3 to rearm tamper protection.
7 Exit Setting mode: Press Disarm twice to exit.
(The keypad LED will now stop flashing.)
Keyfob
1 Press the Arm and Home buttons together and continuously for 5 seconds until the LED stops flashing, to switch off the tamper while installing the new device.
(The siren will beep in response.)
2 Press the Home and Emergency buttons together and continuously for 5 seconds until the LED stops flashing.
(The siren will beep and flash in response.)
3 Press device learn/test buttons (see section 3, step 2) to trigger learning-in signals.
(The siren will beep and flash when each device is learnt in.)
4 When all the devices have been learnt-in press and hold the Disarm button to quit learn mode.
5 Press the Arm and Emergency buttons together and continuously for 5 seconds until the LED stops flashing to rearm tamper protection.
11
12
Changing the batteries
Always use alkaline batteries or the correct type of coin cells as replacements because any other battery can cause problems with the operation of the system. Typical life of batteries is two years. Ensure the correct steps are taken when changing batteries in tamper protected devices.
Siren
The siren will produce a series of pips and flashes when arming and disarming the system when the batteries start getting low. After the warning the batteries will have about enough energy for 1 month’s normal operation before exhaustion.
1 Switch off tamper protection as described in section 4.
The batteries are changed as follows:
2 Remove the siren lid and switch off the siren power.
3 Unscrew the four screws on the battery compartment lid and remove.
4 Remove the four batteries and replace them with four fresh alkaline “D” cells.
5 Switch on siren power and check that the siren beeps and flashes.
Warning After the batteries have been changed the tamper will become active again, either be very careful when fitting the siren cover or switch off the tamper protection again.
6 Replace battery compartment lid and screws and reattach siren lid. Switch tamper protection back on.
• Siren case tamper conditions are also signalled by a series of beeps when the system is armed, but not when the system is disarmed (low battery warning produces a series of pips when armed and disarmed), take care not to confuse the two different conditions.
PIR
When the battery is low the LED will flash when any movement is detected. The batteries are changed as follows:
1 Switch off tamper protection as described in section 4.
2 Loosen the case screw and remove PIR sensor from base to reveal three AAA batteries.
3 Press the learn button to drain residue power.
4 Insert new alkaline batteries observing correct polarity.
5 Refit sensor on base and tighten bottom case screw. Switch tamper protection back on.
• PIR case tamper conditions are also indicated by a flashing LED, check the tamper before changing the batteries.
Door/window sensor
When the battery is low the LED will flash when the door/window is opened. The battery is changed as follows:
1 Switch off tamper protection as described in section 4.
2 Loosen the case screw and remove door/window sensor from base to reveal battery.
3 Using a screwdriver gently lever out the old battery.
4 Insert new CR2032 coin cell with the + side uppermost.
5 Press battery into holder firmly with finger and thumb until a click is heard.
6 Refit sensor on base and tighten bottom case screw. Switch tamper protection back on.
• Door/window sensor case tamper conditions are also indicated by a flashing LED, check the tamper before changing the battery.
Keyfob
When the battery is low the LED will glow dimly when any key is pressed. The battery is changed as follows:
1 Using a coin turn the battery cover anticlockwise to the unlocked position and remove cover and battery.
2 Insert new CR2032 coin cell with the + side uppermost.
3 Replace battery cover.
4 Press any key and check that the LED lights.
If the LED lights the new battery installation is successful.
Keypad
When the battery is low the LED will glow dimly when any key is pressed. The battery is changed as follows:
1 Unscrew the two keypad case screws and remove keypad back to reveal battery.
2 Using a screwdriver gently lever out the old battery.
3 Insert new CR2032 coin cell with the + side uppermost.
4 Press battery into holder firmly with finger and thumb until a click is heard.
5 Press a number key and check that the LED lights.
If the LED lights the new battery installation is successful, screw keypad back on and the battery change is complete.
Smoke Detector
The LED will flash and the sounder will beep every
30 seconds to signal low battery. Change the batteries as soon as possible with fresh AAA alkaline replacements.
Help Button
Remove the cover by loosening the fixing screw and insert a new 12V alkaline battery.
ASSA ABLOY Ltd.
School Street
Willenhall
West Midlands
England
WV13 3PW
Model: HSA3400
Model:
HSA3020
HSA3060
HSA3010
HSA3050
HSA3050
HSA3080
HSA3030
HSA3070
EN 300 220-1 / V2.1.1 (2006-04)
EN 301 489 -1, / V1.6.1 (2004-12)
EN 301 489-3, / V 1.4.1 (2002-08)
EN 60 950 / 2001 + A11 + corrigendum 2004
John Ward
On behalf of ASSA ABLOY Ltd.
Director
Date: 16/11/06
ASSA ABLOY Ltd.
School Street, Willenhall
West Midlands
England, WV13 3PW
17
17
14
Specifications
All devices
Environmental conditions
-10°C to 40°C, relative humidity
70% non-condensing for all units except the external siren. Siren:
-20°C to 50°C, relative humidity
95% non-condensing
Radio operational range
30m in a typical domestic installation, range can vary depending on building construction, device positions and RF environment
Housings ABS/polycarbonate
Siren
Siren output 104dBA sound pressure @ 1m minimum
Radio 433.92MHz AM super heterodyne receiver with jamming detection
Power supply 6V, 4 x D alkaline cells. 2 years typical service life
Passive infra red (PIR)
Detector
Alarm processing Microprocessor controlled dual edge sequential pulse count with pulse length discrimination
Radio 433.92MHz AM transmitter
Power supply 4.5V, 3 x AAA alkaline cells. 2 years typical domestic service life, 1-minute sleep timer
Movement detection range 15m,
110°
Door/window contact
Radio Microprocessor controlled
433.92MHz AM transmitter
Power supply 3V, CR2032 lithium coin cell. 2 years typical domestic service life
Smoke detector
Radio Microprocessor controlled
433.92MHz AM transmitter
Power supply 6V, 4 x AAA alkaline cells. 3 years typical domestic service life
Tested to EN54
Keyfob remote control
Radio Microprocessor controlled
433.92MHz AM transmitter
Power supply 3V,
CR2032 lithium coin cell. 3 years typical domestic service life
Keypad remote control
Radio Microprocessor controlled
433.92MHz AM transmitter
Power supply3V, CR2032 lithium coin cell. 3 years typical domestic service life
Help button
Radio Microprocessor controlled
433.92MHz AM transmitter
Power supply 12V 23A/MN21 alkaline miniature ‘lighter battery’.
3 years typical domestic service life
Troubleshooting
For online assistance, please visit:
www.YaleSupport.com
Siren
Siren does not respond to keypad
• Keypad low battery or bad connection. Check battery connections and polarity, if OK replace battery.
• Siren batteries are completely exhausted. Check siren batteries by removing siren cover, if there is no tamper alarm when removed, replace batteries with new alkaline equivalents.
• Keypad not learnt-in. If siren produces a tamper alarm when the cover is removed, and keypad is
OK, learn-in the keypad.
Siren produces a 3 second alarm when disarmed
• There has been a previous alarm and there might be an intruder still in the premises.
Siren produces a series of pips when armed or disarmed
• The siren has low batteries. Check that the siren produces a series of pips when arming and disarming, indicating low batteries. Change batteries with new alkaline replacements.
• The siren tamper switch has been disturbed.
Check that the siren produces a series of pips only when arming, indicating a tamper condition. Check that the siren cover is firmly secured and the tamper switch plunger is in contact with the wall. If not use suitable packing material to fill gap.
Siren produces an interrupted tone when sounding an alarm
• The siren has low batteries. Change batteries with new alkaline replacements.
Keypad
The keypad LED will not light when the arm key is pressed
• Battery is completely exhausted. Change battery with CR2032 coin cell replacement.
The siren will not respond to the disarm user code
• Ensure that the keypad mode is correct by entering test mode and pressing button “A” then “8”.
Forgotten user PIN code
• Remove battery and reinsert with the number
“3” key pressed. The keypad will go back to the “0000” keypad code. The keypad will now have to be re-learnt into the Siren, see either
“Programming the siren based system” or “Adding accessories” sections.
PIR
PIR does not respond to movement
• Previous movement has triggered the PIR sleep timer (see page 7) is preventing subsequent movement detection. Arm system and vacate protected room for at least 1.5 minutes before testing.
PIR is slow to respond
• This is normal, the PIR has sophisticated false alarm filtering that will filter out random fluctuations and responds to genuine movement across field of view, it is less sensitive walking directly towards it.
PIR gives false alarms
• Check pets have no access to protected area.
• Check that PIR is not pointed at sources of heat or moving objects, e.g. fluttering curtains.
• Check that PIR is not mounted above convector heaters or pointing directly at windows.
PIR LED flashes
• Batteries are low or the tamper switch is disturbed.
Check that the tamper switch spring is making contact with base. If the tamper switch is OK, change batteries with new alkaline replacements.
PIR does not respond to movement after test/ learn button has be pressed
• Batteries are completely exhausted. Change batteries with new alkaline replacements, LED will flash for 30 seconds while components initialise.
Door contact
Door contact LED flashes
• Batteries are low or the tamper switch is disturbed.
Check that the tamper switch spring is making contact with the mounting surface. If the tamper switch is OK, change batteries with new alkaline replacements.
Door contact does not respond to door opening after test/learn button has been pressed
• Batteries are completely exhausted. Change batteries with new alkaline replacements
• The magnet is too far away from the door contact.
Check that the gap between door contact and magnet is not greater than 8mm.
15
Specifications
Specifications
All devices
EMC
Tested to ETS 300 683
Radio Components tested to EN
300 220-1
Passive infra red (PIR) detector
All devices
EMC
Alarm processing
Microprocessor controlled dual edge sequential pulse count with pulse length discrimination
Tested to ETS 300 683
Environmental conditions
-10°C to 40°C, relative humidity
70% non-condensing for all units except the external siren. Siren: -20°C to 50°C, relative humidity 95% noncondensing
Radio operational range
30m in a typical domestic installation, range can vary depending on building construction, device positions and RF environment
Housings ABS/polycarbonate minute sleep timer
Environmental conditions
15m, 110°
-10°C to 40°C, relative humidity except the external siren. Siren: -20°C to 50°C, relative humidity 95% noncondensing
3V, 2 x AAA alkaline cells. 3 years typical domestic service life
Radio operational range
Smoke detector
installation, range can vary depending on building construction, device
433.92MHz AM transmitter positions and RF environment
Housings ABS/polycarbonate
Siren
Siren
Keyfob remote control
Siren output 104dBA sound pressure @
1m minimum
Radio 433.92MHz AM super heterodyne receiver with jamming detection
Power supply 6V, 4 x D alkaline cells. 3 years typical service life
Siren output
Power supply
Microprocessor controlled
1m minimum
Radio
Power supply
12V, 23A/MN21 alkaline miniature "lighter" battery. 3 years
6V, 4 x D alkaline cells. 3
Keypad remote control
Radio Microprocessor controlled
433.92MHz AM transmitter
Power supply 3 x AAA alkaline cells. 3
Radio
Help button
controlled dual edge sequential pulse count with pulse length discrimination
300 683
Environmental conditions -10°C to
3 years typical domestic service life, 1condensing
Radio operational range 30m in a typical domestic installation. Can vary
Radio Microprocessor controlled miniature ‘lighter battery’. 3 years typical domestic service life
Smoke detector
Radio
Microprocessor controlled
433.92MHz AM transmitter
Power supply 6V, 4 x AAA alkaline cells. 3 years typical domestic service life
Keyfob remote control
Radio Microprocessor controlled
433.92MHz AM transmitter
Power supply 12V, 23A/MN21 alkaline miniature "lighter" battery. 3 years typical domestic service life
Keypad remote control
Radio Microprocessor controlled
433.92MHz AM transmitter
Power supply
3 x AAA alkaline cells. 3 years typical domestic service life
Help button
EMC Tested to EN 300 220-1 and ETS
300 683
Environmental conditions -10°C to
40°C, relative humidity 70% noncondensing
Radio operational range 30m in a typical domestic installation. Can vary depending on building construction and
RF environment
Radio Microprocessor controlled
433.92MHz AM transmitter
Power supply 12V 23A/MN21 alkaline miniature ‘lighter battery’. 3 years typical domestic service life
18
18
16
WEEE
Note: Waste electrical products and batteries should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice.
E4 04/10
0560
THE YALE BRAND, with its unparalleled global reach and
range of products, reassures more people in more countries than any other consumer locking solution.
THE ASSA ABLOY GROUP is the world’s leading
manufacturer and supplier of locking solutions, dedicated to satisfying end-user needs for security, safety and convenience.
Advertisement
Key features
- Wireless alarm system
- Up to 20 devices
- Siren with sounder & strobe LEDs
- Entry/Exit feature
- Tamper-proof system
- Long battery life
- Easy to install