PH16NA

16 SEER 2---Stage

Split---System Heat Pump

With R---410A Refrigerant

2 To 5 Tons (024---060)

Wiring Diagram

CONNECTION

DIAGRAM

*CHS

BLK or

RED

*SR

BLK

5

2 1

*C

H

BRN

BLU

*SC

BLK

BLK

YEL

H

C

F

CAP

BLU

BLK

BLU

*ST

YEL

+t

C

S

L1

11

CONT

21

SCHEMATIC DIAGRAM

(LADDER FORM)

C

COMP

R

S 23

CONT

23

L2

RED or BLK

L1

11

CONT

21

YEL

YEL

R

COMP

EQUIP

GND

* CHS

5 2

1

* SR

*SC

H

* ST

+t °

208/230 1Ø

POWER

SUPPLY

L2

23 23

BLK

BRN

OFM

* CH

EQUIP GND

OFM

C

F

YEL

YEL / BLU

DR

CAP

BLK OF1 OF

BRN / YEL

BLK

*CS

RED

* UTS

BLK BLK BLK

RVS C

O O

RVSR

* LPS

YEL / PNK RED

* DTS

RED BLU / PNK

* HPS W2

R R AUXR

YEL / PNK

LOGIC

RVSR

Y

T1

BLU / PNK

Y2 Y2

AUXR

OF1 T2

C

YEL / BLU

*CS * UTS

OF2

C

O

BRN / YEL

ORN

ORN

RVS

Y

Y

T1

CTD

T2 CONT C

120

60

90

30 * LPS *DTS * HPS LOGIC

DF T

C Y O W2 R

R

PNK

PNK

DFT

C

HK32EA003

BLK

YEL WHT

ORN RED

C Y O W2 R E L W3 G

C Y O

W2

R E L

INDOOR UNIT

TERMINAL BLOCK

DIP SWITCH SETTINGS

30

30 MINUTES

1 2 3

60 MINUTES

1 2 3 60

(DEFAULT)

90 MINUTES

1 2 3

120 MINUTES

120

1 2 3

1 2 3

ON

Y2 G

INDOOR THERMOSTAT (NOTE #5)

OR OR OR

QUIET

SHFT

LEGEND

FACTORY POWER WIRING

FACTORY CONTROL WIRING

FIELD CONTROL WIRING

FIELD POWER WIRING

CONDUCTOR ON CIRCUIT BOARD

COMPONENT CONNECTION

1/4-INCH QUICK CONNECT TERMINALS

FIELD SPLICE

JUNCTION

PLUG RECEPTACLE

AUXR

CAP

CB

*CH

AUXILLARY HEAT RELAY

CAPACITOR (DUAL RUN)

CIRCUIT BOARD

CRANKCASE HEATER

* MAY BE FACTORY OR FIELD INSTALLED

*CHS

COMP

CONT

CTD

DFT

DR

*DTS

*HPS

*LPS

OFM

RVS

RVSR

*SC

*SR

*ST

*UTS

CRANKCASE HEATER SWITCH

COMPRESSOR

CONTACTOR

COMPRESSOR TIME DELAY

DEFROST THERMOSTAT

DEFROST RELAY AND CIRCUITRY

DISCHARGE TEMPERATURE SWITCH

HIGH PRESSURE SWITCH

LOW PRESSURE SWITCH

OUTDOOR FAN MOTOR

REVERSING VALVE SOLENOID

REVERSING VALVE SOLENOID

RELAY START CAPACITOR

START RELAY

START THERMISTOR

UNLOADER TEMP SWITCH

NOTES:

1. Compressor and fan motor furnished with inherent thermal protection.

2. To be wired in accordance with national electric code (N.E.C.) and local codes.

3. N.E.C. Class 2, 24 V circuit, min. 40 VA required, 60 VA on units installed with LLS.

4. Use copper conductors only from disconnect to unit.

5. Must use thermostat and sub-base as stated in pre-sale literature.

6. If indoor section has a transformer with a grounded secondary, connect the grounded

side to "C" on the circuit board.

7. If any of the original wire, as supplied, must be replaced, use the same or equivalent wire.

8. Check all electrical connections inside control box for tightness.

9. Do not attempt to operate unit until service valves have been opened.

10. Use conductors suitable for at least 75ºC (167ºF).

90 OFF

(DEFAULT)

FIELD SELECTABLE OPTIONS FOR TIME PERIOD

BETWEEN DEFROST CYCLES (MINUTES)

JUMPERED TEST PINS (USE METAL OBJECT), FIELD SPEED-UP CYCLE

1) MOMENTARILY SHORT PINS AND RELEASE TO BYPASS COMPRESSOR OFF DELAY.

2) SHORT FOR 5+ SEC. AND RELEASE FOR FORCED DEFROST.

3) PERMANENT SHORT WILL BE IGNORED.

DEFROST WILL TERMINATE IN 30 SEC. IF DFT OPEN.

DEFROST WILL TERMINATE NORMALLY IF DFT IS CLOSED.

NOTE

THIS DEFROST CONTROL BOARD CONTAINS A FIVE MINUTE

SHORT CYCLE PROTECTOR. A FIVE MINUTE DELAY WILL

OCCUR BETWEEN COMPRESSOR OFF/ON CYCLES.

335977-101 R E V . B

Fig. 1 – PH16NA 2 -- 5 Tons

E

2012 Payne Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A.

Edition Date: 04/12

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

2

Catalog No: PH16NA---01WD

Replaces: New

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement