PH16NA
16 SEER 2---Stage
Split---System Heat Pump
With R---410A Refrigerant
2 To 5 Tons (024---060)
Wiring Diagram
CONNECTION
DIAGRAM
*CHS
BLK or
RED
*SR
BLK
5
2 1
*C
H
BRN
BLU
*SC
BLK
BLK
YEL
H
C
F
CAP
BLU
BLK
BLU
*ST
YEL
+t
C
S
L1
11
CONT
21
SCHEMATIC DIAGRAM
(LADDER FORM)
C
COMP
R
S 23
CONT
23
L2
RED or BLK
L1
11
CONT
21
YEL
YEL
R
COMP
EQUIP
GND
* CHS
5 2
1
* SR
*SC
H
* ST
+t °
208/230 1Ø
POWER
SUPPLY
L2
23 23
BLK
BRN
OFM
* CH
EQUIP GND
OFM
C
F
YEL
YEL / BLU
DR
CAP
BLK OF1 OF
BRN / YEL
BLK
*CS
RED
* UTS
BLK BLK BLK
RVS C
O O
RVSR
* LPS
YEL / PNK RED
* DTS
RED BLU / PNK
* HPS W2
R R AUXR
YEL / PNK
LOGIC
RVSR
Y
T1
BLU / PNK
Y2 Y2
AUXR
OF1 T2
C
YEL / BLU
*CS * UTS
OF2
C
O
BRN / YEL
ORN
ORN
RVS
Y
Y
T1
CTD
T2 CONT C
120
60
90
30 * LPS *DTS * HPS LOGIC
DF T
C Y O W2 R
R
PNK
PNK
DFT
C
HK32EA003
BLK
YEL WHT
ORN RED
C Y O W2 R E L W3 G
C Y O
W2
R E L
INDOOR UNIT
TERMINAL BLOCK
DIP SWITCH SETTINGS
30
30 MINUTES
1 2 3
60 MINUTES
1 2 3 60
(DEFAULT)
90 MINUTES
1 2 3
120 MINUTES
120
1 2 3
1 2 3
ON
Y2 G
INDOOR THERMOSTAT (NOTE #5)
OR OR OR
QUIET
SHFT
LEGEND
FACTORY POWER WIRING
FACTORY CONTROL WIRING
FIELD CONTROL WIRING
FIELD POWER WIRING
CONDUCTOR ON CIRCUIT BOARD
COMPONENT CONNECTION
1/4-INCH QUICK CONNECT TERMINALS
FIELD SPLICE
JUNCTION
PLUG RECEPTACLE
AUXR
CAP
CB
*CH
AUXILLARY HEAT RELAY
CAPACITOR (DUAL RUN)
CIRCUIT BOARD
CRANKCASE HEATER
* MAY BE FACTORY OR FIELD INSTALLED
*CHS
COMP
CONT
CTD
DFT
DR
*DTS
*HPS
*LPS
OFM
RVS
RVSR
*SC
*SR
*ST
*UTS
CRANKCASE HEATER SWITCH
COMPRESSOR
CONTACTOR
COMPRESSOR TIME DELAY
DEFROST THERMOSTAT
DEFROST RELAY AND CIRCUITRY
DISCHARGE TEMPERATURE SWITCH
HIGH PRESSURE SWITCH
LOW PRESSURE SWITCH
OUTDOOR FAN MOTOR
REVERSING VALVE SOLENOID
REVERSING VALVE SOLENOID
RELAY START CAPACITOR
START RELAY
START THERMISTOR
UNLOADER TEMP SWITCH
NOTES:
1. Compressor and fan motor furnished with inherent thermal protection.
2. To be wired in accordance with national electric code (N.E.C.) and local codes.
3. N.E.C. Class 2, 24 V circuit, min. 40 VA required, 60 VA on units installed with LLS.
4. Use copper conductors only from disconnect to unit.
5. Must use thermostat and sub-base as stated in pre-sale literature.
6. If indoor section has a transformer with a grounded secondary, connect the grounded
side to "C" on the circuit board.
7. If any of the original wire, as supplied, must be replaced, use the same or equivalent wire.
8. Check all electrical connections inside control box for tightness.
9. Do not attempt to operate unit until service valves have been opened.
10. Use conductors suitable for at least 75ºC (167ºF).
90 OFF
(DEFAULT)
FIELD SELECTABLE OPTIONS FOR TIME PERIOD
BETWEEN DEFROST CYCLES (MINUTES)
JUMPERED TEST PINS (USE METAL OBJECT), FIELD SPEED-UP CYCLE
1) MOMENTARILY SHORT PINS AND RELEASE TO BYPASS COMPRESSOR OFF DELAY.
2) SHORT FOR 5+ SEC. AND RELEASE FOR FORCED DEFROST.
3) PERMANENT SHORT WILL BE IGNORED.
DEFROST WILL TERMINATE IN 30 SEC. IF DFT OPEN.
DEFROST WILL TERMINATE NORMALLY IF DFT IS CLOSED.
NOTE
THIS DEFROST CONTROL BOARD CONTAINS A FIVE MINUTE
SHORT CYCLE PROTECTOR. A FIVE MINUTE DELAY WILL
OCCUR BETWEEN COMPRESSOR OFF/ON CYCLES.
335977-101 R E V . B
Fig. 1 – PH16NA 2 -- 5 Tons
E
2012 Payne Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A.
Edition Date: 04/12
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
2
Catalog No: PH16NA---01WD
Replaces: New