Flight 60® - Flight Medical

Flight 60® - Flight Medical
Flight 60
®
Hospital
Acute Care Ventilation
Remarkable performance and features in a portable and intuitive package.
The Flight 60 ventilator is designed to address a wide range of hospital needs
while improving patients’ comfort & independence.
Full Ventilation Package
Advanced ventilation modes
- Pressure and Volume
- New Volume Guarantee mode
- New Bi-Level
- Invasive & non-invasive
Pediatric to adult - 30 ml - 2.2 liter
Advanced Monitoring
Waveforms and Loops
Trends - display up to 72 hours
Lung Mechanics:
- Static/dynamic Compliance
- Resistance
- Plateau Pressure
- Auto PEEP
Safe, Intuitive and Mobile
Extensive alarm system
Exhaled volume monitoring - meeting critical
care requirements
Oxygen sensor - built in
7” touch screen clearly visible from a distance
Lightweight & portable
High pressure and low flow O2 ports
Fully independent internal compressor
Easily connecting to hospitals’ IT systems
Your Partner in Ventilation
FLIGHT 60
Your Partner in Ventilation
CONTROLS
NPPV
SIGH
Synchronized Nebulizer
Nebulization Period
2min 100% O2 Function
Tidal Volume
Breath Rate
Inspiration Time (Ti)
Flow
Pressure Control
Pressure Support (PSV)
PEEP/CPAP
Pressure Trigger
Flow Trigger
Rise Profile
PSV Ti
PSV Flow Termination
Volume Control
Flow Waveform
FiO2
FiO2 Sensor
Manual Breath
Panel Lock
Trends
Maneuvers
Hold Length
Target VtG
PSV min
PSV max
Trigger Delay
30 to 2,200 ml
0 to 60 cmH2O
5 to 60 cmH2O
ON/OFF
VG Mode Controls
Waveforms
Loops
Trends
Airway Pressure LED Gauge
Peak Inspiratory Pressure
Base Pressure
Mean Pressure
Exhaled Tidal Volume
Exhaled Minute Volume
Inhaled Tidal Volume
Inhaled Minute Volume
Actual Breath Rate
Peak Inspiratory Flow
RSBI
Lung Mechanics
FiO2
I:E Ratio
Battery Level
SPECIAL FUNCTIONS
Buzzer Level
Dimensions (WxLxH)
29 x 28 x 25 cm / 11.4” x 11.0”x 9.8”
Weight
6.3 Kg / 13.9 lbs
6.9 Kg / 15.2 lbs (with integrated mixer)
Languages
SIZE AND WEIGHT
OXYGEN
High Pressure
Low Flow Port
Low Flow Blending Bag
Internal integral, electronically
controlled
35 to 90 psi
0 to 15 L/min
0 to 15 L/min
AC Power Inlet
DC Power Inlet
Internal Batteries
Charging Time
100 to 240 VAC, 50-60Hz
12 to 15 VDC
Hot Swappable 12 hours operation
Up to 3 hours
USB x2
RS232 x2
Download Logs, SW Upgrade
Remote Alarm and Monitoring
Operation Temperature
Storage Temperature
Relative Humidity
Operation Altitude
Water/Dust Resistance
-18OC to 50OC / -0.4OF to 122OF
-20OC to 71OC / -4.0OF to 160OF
15% to 95% at 31OC / 88OF
110 kPa to 70 kPa
IP34 (splash proof)
O2 Mixer (optional)
POWER SUPPLY
ALARMS (variable)
Alarm Prioritization
Low Minute Volume
Low Pressure
High Pressure
High Minute Volume
High FiO2
Low FiO2
High Rate
Low Rate
Low Vte
Low Vti
Apnea/Back-Up Ventilation
Quick Start
Power Save
3 to 60 cmH2O
0 to 30 cmH2O
1 to 15 sec
0.5 to 5 sec
30:1
COMMUNICATIONS
3 Levels – Caution, Medium, High
0.0 to 50 L/min
OFF, 1 to 98 cmH2O
4 to 99 cmH2O
0.1 to 50 L/min
31% to 99%, OFF
OFF, 22% to 90%
OFF, 1 to 99 bpm
OFF, 1 to 99 bpm
OFF, 10 to 2,200ml
OFF, 10 to 2,200ml
10-60 sec
Pressure, Flow, Volume
Pressure/Volume & Flow/Volume
Rate, Peak Inspiratory Pressure &
Vte (up to 72 hours)
-10 to 120 cmH2O
0 to 120 cmH2O
0 to 99 cmH2O
0 to 99 cmH2O
0 to 10L
0 to 99L
0 to 10L
0 to 99L
0 to 99 b/min
1 to 120 L/min
0 to 200 min*L
Static and Dynamic Compliance,
Resistance, Plateau Pressure, Auto PEEP
21% to 100%
1:99 to 3:1
100% to 0%, Low, Empty
LOW/HIGH
Keypad buttons with audible
indicator
ON/OFF/NIGHT
English, French, German, Greek,
Hungarian, Italian, Polish, Portuguese, Russian, Spanish, Turkish
5 preset ventilation modes
Keypad Buttons
B-Lev Controls
P High
P Low
T High (Ti)
T Low
Inverse I:E
Check Circuit (Circuit Disconnect),
Low/Empty Battery, O2 Supply
Failed, Check O2 Sensor, Target
Volume not reached
MONITORED PARAMETERS
OFF/LOW/HIGH
(leak compensation up to 30 LPM)
VtG (Tidal Volume Guarantee)
MVG (Minute Volume Guarantee)
ON/OFF
ON/OFF
OFF, 5 to 60 min
ON/OFF
30 to 2,200 ml
1 to 99 b/min
0.1 to 3.0 sec
2 to 100 L/min
5 to 80 cmH2O
0 to 60 cmH2O
0 to 40 cmH2O
-20.0 to -0.1 cmH2O
1 to 20 LPM
5 levels
0.1 to 3 sec
10% to 90%
Time/Flow
Square/Descending
21% to 100%
ON, OFF, Calibrate
0 to 3 sec
ON/OFF
ON/OFF/Clear
Inspiratory Hold, Expiratory Hold
1 to 6 seconds
VG Mode
ALARMS (automatic)
ACMV - PCV/VCV/PRVC
SIMV - PCV/VCV/PRVC
SPONT (CPAP, BPAP)
Volume Guarantee
B-Lev (Bi-Phasic, APRV)
ENVIRONMENTAL
STANDARDS
LIT-0028 Rev A03
Technical Specifications
MODES
IEC 60601-1 ,IEC 60601-1-2 ,IEC
60601-2-12, ASTM 1246F ,
ISO 10651-2/3, RTCA DO-160 F
* NOTE: Some features of the Flight 60 may not be available or cleared in all countries.
For detailed information, contact your local Flight Medical representative.
Flight Medical Innovations Ltd.
www.flight-medical.com
0483
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement