Read more..

Read more..
Fluke 62 Max IR Thermometer
Small in size. Big on toughness.
Introducing the Fluke 62 MAX
Why IR Thermometers?
Temperature is often the first indication of potential
problem in electrical and mechanical applications. But
how can you easily determine if an electrical panel has a
hot spot, a motor is overheating or an HVAC system is
inefcient? The answers is with an infrared (IR)
thermometer. With handheld, non-contact IR
thermometers, you can instantly measure equipment
temperatures in hard to reach or hazardous areas. And
with early detection of abnormal temperatures comes
early correction of problems.
Why Fluke 62 MAX
Designed with your on-the-job need mind, the new
Fluke 62 MAX infrared thermometer is everything you'd
expect from the experts in measurement tools, smaller
In size, extremely accurate and very easy to use. IP 54
rated for dust and water resistance. Precise yet rugged
enough to take a 3- meter drop. In fact, the 62 Max is
so tough, that is the only IR thermometer around you
can use handle without care.
e Dust and water-resistant: [P54 rated for
dust and water resistance
e Rugged: 3-meter (9.8-foot) drop tested
FLUKE.
Calibration
Certificate
INDIA
e Ergonomically designed: Completely Specifications
redesigned for a more comfortable hand Function Parameter
e Small in size: Small and lightweight clips
to your tool belt or belt loop or easily fits Temperature Range
-30 °C to 500 °C (-22 °F to 932 °F)
into your tool box
e Distance to spot: Precise laser Accuracy
technology makes for more accurate and
+ 1.5 °C or + 1.5 % of reading
+ 2.0 at -10 °C to O °C
+ 3.0 at -30 °C to -10 °C
repeatable measurements
e Large, backlit display: Large screen
makes data easier to read, even in dark
areas
Response Time (95 %)
<500 ms (95 % of reading)
Spectral Response: 8 to 14 microns
Emissivity: 0.10 to 1.00
e Min/Max/Avg/Dif: Displays the
Optical Resolution
10:1 (calculated at 90 % energy)
Minimum, maximum or average
Display Resolution
0.1 °C (0.2 °F)
temperature, or the difference between
two measurements
Repeatability of Readings
+ 0.8 % of reading or <+ 1.0 °C (2 °F),
whichever is greater
e Alarm: Hi and low alarms for rapid
display of measurements outside the limits | Power
AA battery
e Power: Both the 62 MAX is powered
by a single, standard AA battery