Intermatic General Catalog

Intermatic General Catalog
General Catalog
WEATHERPROOF
ENERGY CONTROLS
PROFESSIONAL LIGHTING
POOL & SPA CONTROLS
SURGE PROTECTION
CONSUMER PRODUCTS
www.intermatic.com
Providing a Brighter Solution™
A system is defined as a group of units, combined to form a
whole, which operates in unison. Intermatic takes this
definition one step further and combines complete
communication with total connectivity. Instead of
just putting forward a massive listing of part
numbers, Intermatic provides its customers
with a new approach to energy controls that
combines six categories of products into
singular solutions – helping everyone from
distributors and electrical contractors to
architects and designers provide their
customers with smarter and more
reliable energy control systems.
WEATHERPROOF
ENERGY CONTROLS
PROFESSIONAL LIGHTING
POOL & SPA CONTROLS
Table of Contents
SURGE PROTECTION
Commercial/Industrial Applications . . . . . .6
Residential Applications . . . . . . . . . . . . . . .8
Merchandising Support . . . . . . . . . . . . . . .10
Weatherproof Products . . . . . . . . . . . . .13
Energy Controls . . . . . . . . . . . . . . . . . . .20
Professional Lighting . . . . . . . . . . . . . . .58
Pool & Spa Controls . . . . . . . . . . . . . . . .67
Surge Protection . . . . . . . . . . . . . . . . . . .87
Consumer Products . . . . . . . . . . . . . . .121
Cross Reference . . . . . . . . . . . . . . . . . . .146
CONSUMER PRODUCTS
Icon Legend:
Underwriters
Laboratories Listed
UL Component
Recognized
UL Tested to Both
UL & CSA Standards
Knockouts
CSA Tested to Both
CSA & UL Standards
Temperature
CSA Tested to
UL Standards
Shipping Weight
Canadian Standards
Association Approved
Warranty Period
Product Index
133PE1484A . . .70, 71, 72
156ET9402A . . . . . . . .45
156ET9403A . . . . . . . .45
178PA28A . . . . . . .70, 72
22T338GR . . . . . . . . . .39
22T535GR . . . . . . . . . .39
24EG5133 . . . . . . . . .115
2T1985GR . . . . . . . . . .38
2T2040GA . . . . . . . . . .38
2T2502GA . . . . . . . . . .38
2T2292GA . . . . . . . . . .38
2T2293GA . . . . . . . . . .38
2T2331GA . . . . . . . . . .38
2T2365GA . . . . . . . . . .39
2T2366GA . . . . . . . . . .39
2T2485GA . . . . . . . . . .38
2T2500GA . . . . . . . . . .38
2T308A . . . . . . . . . . . .39
2T511GA . . . . . . . . . .38
6ET1398GA . . . . . . . . .39
AG2401C . . . . . . . . . .119
AG2401C-IND . . . . . .119
AG2403C . . . . . . . . . .119
AG2803C . . . . . . . . . .119
AG4801 . . . . . . . . . .119
AG4803C . . . . . . . . . .119
AG6503C . . . . . . . . . .119
AG6503C-IND . . . . . .119
AG6503L . . . . . . . . . .119
AL10210 . . . . . . . . . . .61
AL102-5C . . . . . . . . . .61
AL111 . . . . . . . . . . . .61
AL115 . . . . . . . . . . . .61
AL1160 . . . . . . . . . . . .61
AL12210 . . . . . . . . . . .61
AL122-5C . . . . . . . . . .61
AL300BW . . . . . . . . . .60
AL300MTW . . . . . . . . .60
AL300RTW . . . . . . . . .59
AL300TPWS . . . . . . . .59
AL375V . . . . . . . . . . .61
AL380C . . . . . . . . . . .61
AL385V . . . . . . . . . . .61
AL395 . . . . . . . . . . . .61
AL395V . . . . . . . . . . .61
AL401 . . . . . . . . . . . .61
AL402 . . . . . . . . . . . .61
AL402TA . . . . . . . . . . .61
AL403 . . . . . . . . . . . .61
AL403TA . . . . . . . . . . .61
AL405 . . . . . . . . . . . .62
AL405V . . . . . . . . . . .62
AL406 . . . . . . . . . . . .62
AL406TA . . . . . . . . . . .62
AL407TA . . . . . . . . . . .62
AL408TA . . . . . . . . . . .62
AL409 . . . . . . . . . . . .62
AL409TA . . . . . . . . . . .62
AL425C . . . . . . . . . . .62
AL501 . . . . . . . . . . . .62
AL502 . . . . . . . . . . . .62
AL502DS . . . . . . . . . .62
AL502TA . . . . . . . . . . .63
AL506 . . . . . . . . . . . .63
AL508V . . . . . . . . . . .63
AL510V . . . . . . . . . . .63
AL521 . . . . . . . . . . . .63
AL550 . . . . . . . . . . . .63
AL550DS . . . . . . . . . .63
AL550TA . . . . . . . . . . .63
AL600MTW . . . . . . . . .60
AL600TPWS . . . . . . . .59
AL600TW . . . . . . . . . .59
AL60TW . . . . . . . . . . .60
AL8-12 . . . . . . . . . . . .61
AL900TPWS . . . . . . . .59
AL900TW . . . . . . . . . .59
C8815 . . . . . . . . . . . .30
C8835 . . . . . . . . . . . .30
C8845 . . . . . . . . . . . .30
C8865 . . . . . . . . . . . .30
C8866 . . . . . . . . . . . .30
CA3000 . . . . . . . . .56, 57
CA3500 . . . . . . . . .56, 57
CA3750 . . . . . . . . .56, 57
CA5000 . . . . . . . . .56, 57
CA5100 . . . . . . . . .56, 57
CA5500BR . . . . . . .56, 57
CA600 . . . . . . . . . .56, 57
CA7100 . . . . . . . . .56, 57
CA9000 . . . . . . . . .56, 57
CL1 . . . . . . . . . . . . .134
CL111R . . . . . . . . . .134
CL115 . . . . . . . . . . . .134
CL191 . . . . . . . . . . . .134
CL191K . . . . . . . . . . .134
CL191S . . . . . . . . . . .134
CL191V . . . . . . . . . . .134
CL280 . . . . . . . . . . . .134
CL305P . . . . . . . . . . .134
CL4 . . . . . . . . . . . . .134
CL501 . . . . . . . . . . . .134
CL503TA . . . . . . . . . .134
CL507 . . . . . . . . . . . .135
CL508 . . . . . . . . . . . .135
CL509 . . . . . . . . . . . .135
CL635P . . . . . . . . . . .135
CL635R . . . . . . . . . .135
CL635RK . . . . . . . . . .135
CL635RS . . . . . . . . . .135
CL711 . . . . . . . . . . . .135
CL801BC8 . . . . . . . . .135
CL802BSB6 . . . . . . . .135
CL802P7 . . . . . . . . . .135
CL803S2 . . . . . . . . . .135
CL8041 . . . . . . . . . . .136
CL9 . . . . . . . . . . . . .136
CL905 . . . . . . . . . . . .136
CL905K . . . . . . . . . . .136
CL9S . . . . . . . . . . . .136
CP150HPS . . . . . . . . .66
CS110P . . . . . . . . . .132
CS110TA . . . . . . . . . .132
CS120TA . . . . . . . . . .132
CS140K . . . . . . . . . .132
CS14P . . . . . . . . . . .132
CS17K . . . . . . . . . . .132
CS180C . . . . . . . . . .132
CS200C . . . . . . . . . .132
CS230R . . . . . . . . . .132
CS240 . . . . . . . . . . .132
CS330OB . . . . . . . . .132
CS508K . . . . . . . . . .132
CS508P . . . . . . . . . .133
CS508S . . . . . . . . . .133
CS508TA . . . . . . . . . .133
CS7AC1 . . . . . . . . . .133
CS7CT4 . . . . . . . . . .133
CS7E1 . . . . . . . . . . .133
DD150HPS . . . . . . . . .65
DD175MV . . . . . . . . . .65
DT121C . . . . . . . . . .125
DT17C . . . . . . . . . . .125
DT27C . . . . . . . . . . .125
E1010 . . . . . . . . . . . . .51
E1020 . . . . . . . . . . . . .51
E1120 . . . . . . . . . . . . .51
E1220 . . . . . . . . . . . . .51
E1221 . . . . . . . . . . . . .51
EH10 . . . . . . . . . . . . .37
EH40 . . . . . . . . . . . . .37
EI200 . . . . . . . . . . . . .50
EI200LA . . . . . . . . . . .50
EI200W . . . . . . . . . . .50
EI210 . . . . . . . . . . . . .50
EI205 . . . . . . . . . . . . .50
EI205W . . . . . . . . . . .50
EI205LA . . . . . . . . . . .50
EI215 . . . . . . . . . . . . .50
EI215W . . . . . . . . . . .50
EI215LA . . . . . . . . . . .50
EI210 . . . . . . . . . . . . .50
EI210LA . . . . . . . . . . .50
EI210W . . . . . . . . . . .50
EI220 . . . . . . . . . . . . .50
EI220LA . . . . . . . . . . .50
EI220W . . . . . . . . . . .50
EI230 . . . . . . . . . . . . .50
EI230LA . . . . . . . . . . .50
EI230W . . . . . . . . . . .50
EI500C . . . . . . . . . . . .53
EI500LAC . . . . . . . . . .53
EI500WC . . . . . . . . . . .53
EI600C . . . . . . . . . . . .51
EI600WC . . . . . . . . . . .51
EI600LAC . . . . . . . . . .51
EJ351C . . . . . . . . . . .126
EJ500AC . . . . . . . . . .126
EJ500C . . . . . . . . . . .126
ET100C . . . . . . . . . . . .40
ET100CM . . . . . . . . . .40
ET101C . . . . . . . . . . . .40
ET102C . . . . . . . . . . . .40
ET103C . . . . . . . . . . . .40
ET104C . . . . . . . . . . . .40
ET104CP . . . . . . . . . . .40
ET105C . . . . . . . . . . . .40
ET171C . . . . . . . . . . . .41
ET171CR . . . . . . . . . .41
ET173C . . . . . . . . . . . .41
ET174C . . . . . . . . . . . .41
ET175C . . . . . . . . . . . .41
ET279C . . . . . . . . . . . .41
ET70115C . . . . . . . . . .43
ET70115CR . . . . . . . . .43
ET70115CR24 . . . . . . .43
ET70215C . . . . . . . . . .43
ET70215CR . . . . . . . . .43
ET70215CR24 . . . . . . .43
ET70415CR . . . . . . . . .44
ET70415CR24 . . . . . . .44
ET70815CR . . . . . . . . .44
ET70815CR24 . . . . . . .44
ET71615CR . . . . . . . . .44
ET71615CR24 . . . . . . .44
ET7232M . . . . . . . . . .45
ET7232M1 . . . . . . . . .45
ET8015C . . . . . . . . . . .42
ET8015CPD82 . . . . . . .42
ET8015CR . . . . . . . . . .42
ET8115C . . . . . . . . . . .42
ET8115CPD82 . . . . . . .42
ET8115CR . . . . . . . . . .42
ET8215C . . . . . . . . . . .42
ET8215CPD82 . . . . . . .42
ET8215CR . . . . . . . . . .42
FD12HC . . . . . . . . . . .48
FD12HH . . . . . . . . . . .48
FD12HHW . . . . . . . . . .48
FD12HWC . . . . . . . . . .48
FD15MAC . . . . . . . . . .48
FD15MC . . . . . . . . . . .48
FD15MH . . . . . . . . . . .48
FD15MHW . . . . . . . . .48
FD15MWC . . . . . . . . .48
FD2H . . . . . . . . . . . . .48
FD2HW . . . . . . . . . . . .48
FD30MAC . . . . . . . . . .48
FD30MC . . . . . . . . . . .48
FD30MH . . . . . . . . . . .48
FD30MHW . . . . . . . . .48
FD30MWC . . . . . . . . .48
FD312HW . . . . . . . . . .48
FD32H . . . . . . . . . . . .48
FD32HW . . . . . . . . . . .48
FD34H . . . . . . . . . . . .48
FD34HW . . . . . . . . . . .48
FD36H . . . . . . . . . . . .48
FD36HW . . . . . . . . . . .48
FD415M . . . . . . . . . . .48
FD430M . . . . . . . . . . .48
FD430MW . . . . . . . . . .48
FD460M . . . . . . . . . . .48
FD460MW . . . . . . . . . .48
FD46H . . . . . . . . . . . .48
FD46HW . . . . . . . . . . .48
FD4H . . . . . . . . . . . . .48
FD4HW . . . . . . . . . . . .48
FD5M . . . . . . . . . . . . .48
FD5MW . . . . . . . . . . .48
FD60HH . . . . . . . . . . .48
FD60MAC . . . . . . . . . .48
FD60MC . . . . . . . . . . .48
FD60MH . . . . . . . . . . .48
FD60MHW . . . . . . . . .48
FD60MWC . . . . . . . . .48
FD6H . . . . . . . . . . . . .48
FD6HHW . . . . . . . . . . .48
FD6HW . . . . . . . . . . . .48
FF12HC . . . . . . . . . . .49
FF12HHC . . . . . . . . . .49
FF15MC . . . . . . . . . . .49
FF15MH . . . . . . . . . . .49
FF2H . . . . . . . . . . . . .49
FF30MC . . . . . . . . . . .49
FF30MH . . . . . . . . . . .49
FF312H . . . . . . . . . . .49
FF312HH . . . . . . . . . .49
FF315M . . . . . . . . . . .49
FF32H . . . . . . . . . . . .49
FF32HH . . . . . . . . . . .49
FF330M . . . . . . . . . . .49
FF34H . . . . . . . . . . . .49
FF34HH . . . . . . . . . . .49
FF360M . . . . . . . . . . .49
FF36H . . . . . . . . . . . .49
FF412H . . . . . . . . . . .49
FF415M . . . . . . . . . . .49
FF430M . . . . . . . . . . .49
FF460M . . . . . . . . . . .49
FF46H . . . . . . . . . . . .49
FF4H . . . . . . . . . . . . .49
FF5M . . . . . . . . . . . . .49
FF5MH . . . . . . . . . . . .49
FF60MC . . . . . . . . . . .49
FF60MHC . . . . . . . . . .49
FF6H . . . . . . . . . . . . .49
FF6HH . . . . . . . . . . . .49
FL035HPS . . . . . . . . . .65
FL050HPS . . . . . . . . . .65
FL050MH . . . . . . . . . .65
FL070HPS . . . . . . . . . .65
FL070MH . . . . . . . . . .65
FL100HPS . . . . . . . . . .65
FL100MH . . . . . . . . . .65
FL150HPS . . . . . . . . . .65
FL150MH . . . . . . . . . .65
FL150Q . . . . . . . . . . .66
FL175MH . . . . . . . . . .65
FL250HPS . . . . . . . . . .65
FL250MH . . . . . . . . . .65
FL300Q . . . . . . . . . . .66
FL400HPS . . . . . . . . . .65
FL400MH . . . . . . . . . .65
FL500Q . . . . . . . . . . .66
HA01C . . . . . . . . . . .123
HA02C . . . . . . . . . . .123
HA03C . . . . . . . . . . .123
HA04C . . . . . . . . . . .123
HA05C . . . . . . . . . . .124
HA06C . . . . . . . . . . .124
HA07 . . . . . . . . . . . .124
HA09C . . . . . . . . . . .124
HB1116R . . . . . . . . .128
HB112C . . . . . . . . . .126
HB113C . . . . . . . . . .126
HB114C . . . . . . . . . .126
HB31R . . . . . . . . . . .127
HB35R . . . . . . . . . . .127
HB51RC . . . . . . . . . .127
HB61RC . . . . . . . . . .127
HB77RC . . . . . . . . . .128
HB88RC . . . . . . . . . .128
IG11246 . . . . . . . . . .114
IG11266 . . . . . . . . . .114
IG11266BLK10 . . . . . .114
IG11466 . . . . . . . . . .114
IG1201EH . . . . . . . . .101
Intermatic’s headquarters and
main manufacturing facilities in
Spring Grove, Illinois... making
quality products since 1891.
Visit us on our website at
www.intermatic.com for the
most up to date information on
Intermatic products.
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
3
IG1201F20 . . . . . . . .113
IG1201LH . . . . . . . . .103
IG1240FMP3 . . . . . . .116
IG1240RC . . . . . . . . .116
IG1300-2T-1C . . . . . .116
IG1300-4T-2C . . . . . .116
IG141 . . . . . . . . . . . .114
IG141T . . . . . . . . . . .114
IG143 . . . . . . . . . . . .114
IG143T . . . . . . . . . . .114
IG1866A . . . . . . . . . .114
IG1C . . . . . . . . . . . . .118
IG1C3R . . . . . . . . . . .118
IG1CM . . . . . . . . . . .118
IG1SRMP . . . . . . . . .115
IG2012B15 . . . . . . . .114
IG20615 . . . . . . . . . .114
IG2066 . . . . . . . . . . .114
IG2083ECY . . . . . . . . .99
IG2083LYH . . . . . . . .103
IG2083YECA . . . . . . . .98
IG2083YEH . . . . . . . .101
IG2086 . . . . . . . . . . .114
IG20B12 . . . . . . . . . .114
IG2401ECS . . . . . . . . .99
IG2401EH . . . . . . . . .101
IG2401F20 . . . . . . . .113
IG2401LH . . . . . . . . .103
IG2401SECA . . . . . . . .98
IG2403DECA . . . . . . . .98
IG2403DEH . . . . . . . .101
IG2403ECD . . . . . . . . .99
IG2403LDH . . . . . . . .103
IG250LA . . . . . . . . . .120
IG251 . . . . . . . . . . . .117
IG2T . . . . . . . . . . . . .118
IG2T3R . . . . . . . . . . .117
IG2TM . . . . . . . . . . .117
IG3240FMP3 . . . . . . .116
IG3240RC . . . . . . . . .116
IG4803DECA . . . . . . . .98
IG4803DEH . . . . . . . .101
IG4803ECD . . . . . . . . .99
IG4803ECY . . . . . . . . .99
IG4803LDH . . . . . . . .103
IG4803LYH . . . . . . . .103
IG4803YECA . . . . . . . .98
IG4803YEH . . . . . . . .101
IG4TM . . . . . . . . . . .117
IG9638S55 . . . . . . . .114
IGFLUSH MOUNT KIT .118
K1121 . . . . . . . . . . . .24
K1122 . . . . . . . . . . . .24
K1221 . . . . . . . . . . . .24
K1222 . . . . . . . . . . . .24
K4021C . . . . . . . . . . .21
K4022 . . . . . . . . . . . .21
K4023C . . . . . . . . . . .21
K4024 . . . . . . . . . . . .21
K4027 . . . . . . . . . . . .21
K4033 . . . . . . . . . . . .21
K4035 . . . . . . . . . . . .21
K4121C . . . . . . . . . . .22
K4121M . . . . . . . . . . .22
K4122 . . . . . . . . . . . .22
K4123C . . . . . . . . . . .22
K4123M . . . . . . . . . . .22
K4124 . . . . . . . . . . . .22
K4127 . . . . . . . . . . . .22
K4133 . . . . . . . . . . . .22
K4135 . . . . . . . . . . . .22
K4136M . . . . . . . . . . .22
K4141C . . . . . . . . . . .22
K4221C . . . . . . . . . . .22
K4222 . . . . . . . . . . . .22
K4223C . . . . . . . . . . .22
K4224 . . . . . . . . . . . .22
K4233 . . . . . . . . . . . .22
K4235 . . . . . . . . . . . .22
K4236C . . . . . . . . . . .22
K4251 . . . . . . . . . . . .22
K4253 . . . . . . . . . . . .22
K4321C . . . . . . . . . . .21
K4421M . . . . . . . . . . .22
K4423M . . . . . . . . . . .22
K4521 . . . . . . . . . . . .23
K4522 . . . . . . . . . . . .23
K4524 . . . . . . . . . . . .23
K4533 . . . . . . . . . . . .23
K4535 . . . . . . . . . . . .23
K4536SS . . . . . . . . . .25
K4536SST . . . . . . . . . .25
LC2000 . . . . . . . . . . . .24
LC4521C . . . . . . . . . . .23
LC4521LA . . . . . . . . . .23
LC4523 . . . . . . . . . . . .23
LC4523LA . . . . . . . . . .23
LC4527 . . . . . . . . . . . .23
LC4535 . . . . . . . . . . . .23
LC4535LA . . . . . . . . . .23
LC4536LAC . . . . . . . . .23
LC4536C . . . . . . . . . . .23
4
LD622 . . . . . . . . . . .138
LD622L . . . . . . . . . . .138
LD641 . . . . . . . . . . .138
LT10 . . . . . . . . . . . . .136
LT13 . . . . . . . . . . . . .136
LT13N . . . . . . . . . . . .136
LT13S . . . . . . . . . . . .136
LT406 . . . . . . . . . . . .137
LT406N . . . . . . . . . . .137
LT8K . . . . . . . . . . . . .136
LT9 . . . . . . . . . . . . .136
LV103 . . . . . . . . . . . .138
LV108 . . . . . . . . . . . .138
LV181 . . . . . . . . . . . .138
LV183 . . . . . . . . . . . .138
LX1 . . . . . . . . . . . . .138
LX703 . . . . . . . . . . . .142
LX9Z . . . . . . . . . . . .138
LZ1 . . . . . . . . . . . . .141
LZ10130 . . . . . . . . . .141
LZ10131 . . . . . . . . . .141
LZ10131P . . . . . . . . .141
LZ11101OB . . . . . . . .139
LZ11101P . . . . . . . . .139
LZ11101RB . . . . . . . .139
LZ11101V . . . . . . . . .140
LZ11771H . . . . . . . . .140
LZ11771HK . . . . . . . .140
LZ13RP4 . . . . . . . . . .144
LZ14001H . . . . . . . . .140
LZ14001HP . . . . . . . .140
LZ15004 . . . . . . . . . .144
LZ16220 . . . . . . . . . .143
LZ16551 . . . . . . . . . .144
LZ191 . . . . . . . . . . . .139
LZ191K . . . . . . . . . . .139
LZ1W . . . . . . . . . . . .141
LZ1WU . . . . . . . . . . .144
LZ20601P . . . . . . . . .142
LZ21811K . . . . . . . . .140
LZ230 . . . . . . . . . . . .140
LZ280RP4 . . . . . . . . .144
LZ3 . . . . . . . . . . . . .141
LZ302 . . . . . . . . . . . .141
LZ303RB . . . . . . . . . .143
LZ305FP . . . . . . . . . .143
LZ305P . . . . . . . . . . .139
LZ306 . . . . . . . . . . . .144
LZ307 . . . . . . . . . . . .144
LZ308 . . . . . . . . . . . .144
LZ310 . . . . . . . . . . . .143
LZ312 . . . . . . . . . . . .142
LZ313 . . . . . . . . . . . .144
LZ314 . . . . . . . . . . . .143
LZ3W . . . . . . . . . . . .141
LZ406 . . . . . . . . . . . .140
LZ407 . . . . . . . . . . . .140
LZ413 . . . . . . . . . . . .142
LZ413RP4 . . . . . . . . .142
LZ414 . . . . . . . . . . . .142
LZ415 . . . . . . . . . . . .142
LZ419 . . . . . . . . . . . .143
LZ418 . . . . . . . . . . . .140
LZ422WBR . . . . . . . .140
LZ422W . . . . . . . . . .140
LZ4H . . . . . . . . . . . .141
LZ4HW . . . . . . . . . . .141
LZ4HWGR . . . . . . . . .141
LZ4M . . . . . . . . . . . .141
LZ4MK . . . . . . . . . . .141
LZ4MOB . . . . . . . . . .141
LZ501RP4 . . . . . . . . .144
LZ511A . . . . . . . . . . .143
LZ511B . . . . . . . . . . .143
LZ511C . . . . . . . . . . .143
LZ511R . . . . . . . . . . .143
LZ51GR . . . . . . . . . .139
LZ53RP4 . . . . . . . . . .144
LZ6 . . . . . . . . . . . . .141
LZ601 . . . . . . . . . . . .139
LZ602 . . . . . . . . . . . .139
LZ603 . . . . . . . . . . . .139
LZ604B . . . . . . . . . . .143
LZ635RP4 . . . . . . . . .144
LZ701 . . . . . . . . . . . .142
LZ701W . . . . . . . . . .142
LZ702 . . . . . . . . . . . .142
LZ702W . . . . . . . . . .142
LZ703W . . . . . . . . . .142
LZ704 . . . . . . . . . . . .142
LZ704W . . . . . . . . . .142
LZ705 . . . . . . . . . . . .142
LZ7052 . . . . . . . . . . .142
LZ706 . . . . . . . . . . . .143
LZ7CT4 . . . . . . . . . . .139
LZ7FC4 . . . . . . . . . . .139
LZ7Z6 . . . . . . . . . . . .139
LZ90004 . . . . . . . . . .144
LZB1 . . . . . . . . . . . .144
ML100T . . . . . . . . . .138
ML10401 . . . . . . . . .138
ML10781 . . . . . . . . .138
ML11183 . . . . . . . . .138
ML121RT . . . . . . . . .138
ML200RT . . . . . . . . .138
ML200RTW . . . . . . . .138
ML300RTW . . . . . . . .138
ML44T . . . . . . . . . . .138
ML600TW . . . . . . . . .138
ML60704 . . . . . . . . .138
ML60721 . . . . . . . . .138
ML60722 . . . . . . . . .138
ML60TW . . . . . . . . . .138
ML88T . . . . . . . . . . .138
ML900TW . . . . . . . . .138
ML90401 . . . . . . . . .138
ML90708 . . . . . . . . .138
ML91103 . . . . . . . . .138
MZ101 . . . . . . . . . . .145
MZ102 . . . . . . . . . . .145
MZ105 . . . . . . . . . . .145
MZ204G . . . . . . . . . .145
MZ301 . . . . . . . . . . .145
MZ501 . . . . . . . . . . .145
MZ902 . . . . . . . . . . .145
MZ904 . . . . . . . . . . .145
MZ951 . . . . . . . . . . .145
MZ952 . . . . . . . . . . .145
MZ953 . . . . . . . . . . .145
NA401 . . . . . . . . . . .133
NA501 . . . . . . . . . . .133
NE1C . . . . . . . . . . . .129
NE200C . . . . . . . . . .129
NE250C . . . . . . . . . .129
NE2C . . . . . . . . . . . .129
NE3BC . . . . . . . . . . .129
NE5C . . . . . . . . . . . .129
P1101 . . . . . . . . . . . .85
P1102FE . . . . . . . . . .83
P1102ME . . . . . . . . . .83
P1103FE . . . . . . . . . .83
P1103ME . . . . . . . . . .83
P1121 . . . . . . . . . . . .85
P1131 . . . . . . . . . . . .85
P1161 . . . . . . . . . . . .85
P1203FR . . . . . . . . . .83
P1261P . . . . . . . . . . .85
P1261PE . . . . . . . . . . .85
P1353ME . . . . . . . . . .70
P171-30 . . . . . . . . . . .28
P4243ME . . . . . . . . . .71
P7101ME . . . . . . . . . .83
P7102ME . . . . . . . . . .83
P7103ME . . . . . . . . . .83
PA114 . . . . . . . . . . . .86
PAV215 . . . . . . . . . . .86
PAV215C . . . . . . . . . . .86
PAV220 . . . . . . . . . . .86
PAV220C . . . . . . . . . . .86
PAV315 . . . . . . . . . . .86
PAV315C . . . . . . . . . . .86
PAV320 . . . . . . . . . . .86
PAV320C . . . . . . . . . . .86
PE1501RC . . . . . . . . . .73
PE153 . . . . . . . . . . . .72
PE153F . . . . . . . . . . . .72
PE153P . . . . . . . . . . .72
PE153PF . . . . . . . . . . .72
PE153PW . . . . . . . . . .72
PE153PWF . . . . . . . . .72
PE153W . . . . . . . . . . .72
PE153WF . . . . . . . . . .72
PE1541RC . . . . . . . . . .73
PE24VA . . . . . . . . . . .86
PE25300 . . . . . . . . . . .73
PE25300 . . . . . . . . . . .73
PE25K120V . . . . . . . . .69
PE25K240V . . . . . . . . .69
PE40K120V . . . . . . . . .69
PE40K240V . . . . . . . . .69
PE45343RC . . . . . . . . .68
PE45343RCT1 . . . .68, 78
PE45343RCT3 . . . .68, 78
PE650 . . . . . . . . . . . .68
PE950 . . . . . . . . . . . .68
PEDCELL . . . . . . . . . .69
PEDCHLR . . . . . . . . . .69
PF1102 . . . . . . . . . . . .80
PF1102M . . . . . . . . . .80
PF1102MT . . . . . . . . .80
PF1102T . . . . . . . . . . .80
PF1103 . . . . . . . . . . . .80
PF1103M . . . . . . . . . .80
PF1103MT . . . . . . . . .80
PF1103T . . . . . . . . . . .80
PF1112T . . . . . . . . . . .81
PF1202T . . . . . . . . . . .81
PF1222TB . . . . . . . . . .81
PG1000-208-3Y . . . . .105
PG1000-240-2S . . . . .105
PG1000-480-3D . . . . .105
PG1000-480-3Y . . . . .105
PG100-208-3Y . . . . . . .93
PG100-240-2S . . . . . . .93
PG100-240-3HLD . . . . .93
PG100-480-3DLL . . . . .93
PG100-480-3Y . . . . . . .93
PG1500-208-3Y . . . . .104
PG1500-240-2S . . . . .104
PG1500-480-3D . . . . .104
PG1500-480-3Y . . . . .104
PG20-208-3Y . . . . . . .102
PG20-240-2S . . . . . . .102
PG20-240-3HLD . . . . .102
PG20-480-3D . . . . . . .102
PG20-480-3Y . . . . . . .102
PG3000-208-3Y . . . . . .96
PG3000-240-2S . . . . . .96
PG3000-240-3HLD . . . .96
PG3000-480-3DLL . . . .96
PG3000-480-3Y . . . . . .96
PG3000-600-3D . . . . . .96
PG3000-600-3Y . . . . . .96
PG3500-208-3Y . . . . . .94
PG3500-240-2S . . . . . .94
PG3500-240-3HLD . . . .94
PG3500-480-3DLL . . . .94
PG3500-480-3Y . . . . . .94
PG3500-600-3D . . . . . .94
PG3500-600-3Y . . . . . .94
PG4001-208-3Y . . . . . .92
PG4001-240-2S . . . . . .92
PG4001-240-3HLD . . . .92
PG4001-480-3DLL . . . .92
PG4001-480-3Y . . . . . .92
PG4001-600-3D . . . . . .92
PG4001-600-3Y . . . . . .92
PG40-240-2S . . . . . . .100
PG40-208-3Y . . . . . . .100
PG40-240-3HLD . . . . .100
PG40-480-3D . . . . . . .100
PG40-480-3Y . . . . . . .100
PG4501-208-3Y . . . . . .91
PG4501-240-2S . . . . . .91
PG4501-240-3HLD . . . .91
PG4501-480-3DLL . . . .91
PG4501-480-3Y . . . . . .91
PG4501-600-3D . . . . . .91
PG4501-600-3Y . . . . . .91
PG5001-208-3Y . . . . . .90
PG5001-240-2S . . . . . .90
PG5001-240-3HLD . . . .90
PG5001-480-3DLL . . . .90
PG5001-480-3Y . . . . . .90
PG5001-600-3D . . . . . .90
PG5001-600-3Y . . . . . .90
PG60-208-3Y . . . . . . . .97
PG60-240-2S . . . . . . . .97
PG60-240-3HLD . . . . . .97
PG60-480-3DLL . . . . . .97
PG60-480-3Y . . . . . . . .97
PG80-208-3Y . . . . . . . .95
PG80-240-2S . . . . . . . .95
PG80-240-3HLD . . . . . .95
PG80-480-3DLL . . . . . .95
PG80-480-3Y . . . . . . . .95
PJB2175 . . . . . . . . . . .86
PJB4175 . . . . . . . . . . .86
PR3C . . . . . . . . . . . .129
PX100 . . . . . . . . . . . .79
PX100S . . . . . . . . . . .79
PX300 . . . . . . . . . . . .79
PX300S . . . . . . . . . . .79
PX600 . . . . . . . . . . . .79
PX600S . . . . . . . . . . .79
R8806P101C . . . . . . . .31
R8815P101C . . . . . . . .31
R8816P101C . . . . . . . .31
RC2163BE . . . . . . . . . .82
RC2163BFE . . . . . . . . .82
RC2163E . . . . . . . . . .82
RC2163FE . . . . . . . . . .82
RC2263BE . . . . . . . . . .82
RC2263E . . . . . . . . . .82
RC2403RT . . . . . . . . .82
RC613 . . . . . . . . . . . .84
RC613L . . . . . . . . . . .84
RC613R . . . . . . . . . . .84
RC615 . . . . . . . . . . . .84
RC939 . . . . . . . . . . . .84
SC240 . . . . . . . . . . .132
SG160K-208-3Y . . . . .109
SG160K-240-3HLD . . .109
SG160K-480-3D . . . . .109
SG160K-480-3Y . . . . .109
SG240K-208-3Y . . . . .108
SG240K-240-3HLD . . .108
SG240K-480-3D . . . . .108
SG240K-480-3Y . . . . .108
SG320K-208-3Y . . . . .107
SG320K-240-3HLD . . .107
SG320K-480-3D . . . . .107
SG320K-480-3Y . . . . .107
SM2200*1 . . . . . . . . .46
SM2200*16 . . . . . . . .47
SM2200*2 . . . . . . . . .47
SM2200*3 . . . . . . . . .47
SM2200*4 . . . . . . . . .47
SM2200*5 . . . . . . . . .47
SM2200*6 . . . . . . . . .47
SM2200*7 . . . . . . . . .47
SM2200*8 . . . . . . . . .47
SM4400*1 . . . . . . . . .47
SM4400*10 . . . . . . . .47
SM4400*11 . . . . . . . .47
SM4400*12 . . . . . . . .47
SM4400*13 . . . . . . . .47
SM4400*14 . . . . . . . .47
SM4400*16 . . . . . . . .47
SM4400*2 . . . . . . . . .47
SM4400*3 . . . . . . . . .47
SM4400*4 . . . . . . . . .47
SM4400*5 . . . . . . . . .47
SM4400*6 . . . . . . . . .47
SM4400*7 . . . . . . . . .47
SM4400*8 . . . . . . . . .47
SM4400*9 . . . . . . . . .47
SM6600*1 . . . . . . . . .47
SM6600*10 . . . . . . . .47
SM6600*16 . . . . . . . .47
SM6600*2 . . . . . . . . .47
SM6600*3 . . . . . . . . .47
SM6600*4 . . . . . . . . .47
SM6600*5 . . . . . . . . .47
SM6600*6 . . . . . . . . .47
SM6600*7 . . . . . . . . .47
SM6600*8 . . . . . . . . .47
SM6600*9 . . . . . . . . .47
SP130B . . . . . . . . . .130
SP230B . . . . . . . . . .130
SP440B . . . . . . . . . .130
SP500 . . . . . . . . . . .130
SP640B . . . . . . . . . .130
ST01AC . . . . . . . . . .126
ST01C . . . . . . . . . . .126
T10000R . . . . . . . .39, 74
T10004R . . . . . . . .74, 78
T10004RT1 . . . . . . . . .78
T10004RT3 . . . . . . . . .78
T101 . . . . . . . . . . . . .26
T10101R . . . . . . . . . . .74
T101B . . . . . . . . . . . .26
T101P . . . . . . . . . . . .26
T101R . . . . . . . . . . . .26
T102 . . . . . . . . . . . . .26
T102P . . . . . . . . . . . .26
T102R . . . . . . . . . . . .26
T103 . . . . . . . . . . . . .26
T103P . . . . . . . . . . . .26
T103R . . . . . . . . . . . .26
T104 . . . . . . . . . . . . .26
T10404R . . . . . . . . . . .74
T104-20 . . . . . . . . . . .36
T104P . . . . . . . . . . . .26
T104R . . . . . . . . . . . .26
T105 . . . . . . . . . . . . .26
T10604R . . . . . . . . . . .74
T106R . . . . . . . . . . . .26
T12404R . . . . . . . . . . .74
T1471BCR . . . . . . . . . .27
T1471BR . . . . . . . . . .27
T1472BR . . . . . . . . . .27
T1475BR . . . . . . . . . .27
T171 . . . . . . . . . . . . .27
T171CR . . . . . . . . . . .27
T172 . . . . . . . . . . . . .27
T173 . . . . . . . . . . . . .27
T173CR . . . . . . . . . . .27
T173R . . . . . . . . . . . .27
T174 . . . . . . . . . . . . .27
T174CR . . . . . . . . . . .27
T174R . . . . . . . . . . . .27
T175 . . . . . . . . . . . . .27
T176 . . . . . . . . . . . . .27
T1871BR . . . . . . . . . .27
T1905 . . . . . . . . . . . . .29
T1905E . . . . . . . . . . . .29
T1906 . . . . . . . . . . . . .29
T1975 . . . . . . . . . . . . .29
T1975E . . . . . . . . . . . .29
T1975ER . . . . . . . . . . .29
T1975R . . . . . . . . . . .29
T1976 . . . . . . . . . . . . .29
T1976R . . . . . . . . . . .29
T20004R . . . . . . . . . . .75
T2005 . . . . . . . . . . . . .33
T2006 . . . . . . . . . . . . .33
T21000R . . . . . . . . . . .75
T21001R . . . . . . . . . . .75
T21004R . . . . . . . . . . .75
T30000R5 . . . . . . . . . .76
T30004R . . . . . . . . . . .76
T30000R . . . . . . . . . . .39
T30401R . . . . . . . . . . .76
T30404R . . . . . . . . . . .76
T30604R . . . . . . . . . . .76
T32404R . . . . . . . . . . .76
T40000R . . . . . . . .39, 77
T40000R4 . . . . . . . . . .77
T40003RT3 . . . . . . . . .78
T40004R5 . . . . . . . . . .77
T40004RSS . . . . . . . . .77
T40004RT1 . . . . . . . . .78
T40004RT3 . . . . . . . . .78
T40404R5 . . . . . . . . . .77
T51211BC . . . . . . . . . .32
T51311BC . . . . . . . . . .32
T7401B . . . . . . . . . . . .34
T7402B . . . . . . . . . . . .34
T7801B . . . . . . . . . . . .34
T7802B . . . . . . . . . . . .34
T8805P101C . . . . . . . .31
T8845PV . . . . . . . . . . .31
TB121C . . . . . . . . . . .125
TN111C . . . . . . . . . .125
TN111GC . . . . . . . . .125
TN311C . . . . . . . . . .125
TN711C . . . . . . . . . .125
TN811C . . . . . . . . . .125
TS100RS . . . . . . . . . .38
UG240R . . . . . . . . . .120
UG28A2083Y . . . . . . .112
UG28A2401S . . . . . . .112
UG28A2403D . . . . . . .112
UG28A4803D . . . . . . .112
UG28A4803Y . . . . . . .112
UG30A2083Y . . . . . . .111
UG30A2401S . . . . . . .111
UG30A2403D . . . . . . .111
UG30A2403G . . . . . . .111
UG30A4803D . . . . . . .111
UG30A4803Y . . . . . . .111
UG40A2083Y . . . . . . .110
UG40A2401S . . . . . . .110
UG40A2403D . . . . . . .110
UG40A2403G . . . . . . .110
UG40A4803D . . . . . . .110
UG40A4803Y . . . . . . .110
V45471CR . . . . . . . . . .35
V45471R . . . . . . . . . .35
V45472CR . . . . . . . . . .35
V45472R . . . . . . . . . .35
WH40 . . . . . . . . . . . . .36
WL035HPS . . . . . . . . .64
WL050HPS . . . . . . . . .64
WL050MH . . . . . . . . . .64
WL070HPS . . . . . . . . .64
WL070HPSPC . . . . . . .66
WL070MH . . . . . . . . . .64
WL100HPS . . . . . . . . .64
WL100MH . . . . . . . . . .64
WL150HPS . . . . . . . . .64
WL150MH . . . . . . . . . .64
WL175MH . . . . . . . . . .64
WL250HPS . . . . . . . . .64
WL250MH . . . . . . . . . .64
WL400HPS . . . . . . . . .64
WL400MH . . . . . . . . . .64
WP1000C . . . . . . . . . .19
WP1000GC . . . . . . . . .19
WP1000HC . . . . . .14, 19
WP1000HGC . . . . . . . .19
WP1000HRC . . . . . . . .16
WP1000RC . . . . . . . . .16
WP101 . . . . . . . . . . . .18
WP1010C . . . . . . . . . .19
WP1010HC . . . . . .14, 19
WP1010HMC . . . . .17, 19
WP1010MC . . . . . .17, 19
WP102 . . . . . . . . . . . .18
WP1020C . . . . . . .14, 19
WP103 . . . . . . . . . . . .18
WP1030C . . . . . . .14, 19
WP1030MC . . . . . .17, 19
WP1050 . . . . . . . .14, 19
WP107 . . . . . . . . . . . .18
WP1100C . . . . . . .14, 19
WP1100WC . . . . . . . . .19
WP1110C . . . . . . .14, 19
WP1110WC . . . . . . . . .19
WP1150C . . . . . . .14, 19
WP1220C . . . . . . .14, 19
WP1230C . . . . . . .14, 19
WP1250C . . . . . . .14, 19
WP17 . . . . . . . . . . . . .18
WP2000 . . . . . . . . . . .16
WP213 . . . . . . . . . . . .18
WP217 . . . . . . . . . . . .18
WP3100 . . . . . . . .14, 15
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Grounded in a tradition of innovation and service
In 1891, Intermatic began producing portable fare registers for
streetcars. Over the next 115 years, Intermatic developed a huge
variety of products that have increased the safety, productivity and
convenience of homes and businesses around the world.
Driven by new technology and the needs of our customers
Today, Intermatic is the leading supplier of high quality energy
control products for industrial and commercial markets — moving
into the 21st century with an extensive line of technology-driven
products backed by an unparalleled level of customer service.
Based on improving convenience and safety
Intermatic is committed to making life productive, convenient
and safe through the innovative use of electrical current.
Continual product innovation, creative marketing and effective
brand management makes Intermatic the most pioneering
company within the wholesale distribution channel.
Your total energy management solution
Through our family of products, Intermatic provides a total
solution for your energy management issues. Through our
family of expert sales, training and technical personnel,
Intermatic provides complete sales and marketing support.
5
6
Commercial and Industrial Applications
Intermatic has everything contractors, maintenance personnel and plant or facility managers
need to keep their factories, centers and businesses running at their peak.
Intermatic Commercial and Industrial
Applications
•
•
•
•
•
Interior and exterior lighting control
Parking lot lighting control
Mechanical time switches
Electronic time switches
Service entrance and panelboard surge
protection
• Point-of-use surge protection
• Exterior receptacle protection
• Landscape lighting
Intermatic has a full line of commercial and
industrial products needed to reduce
electricity and labor costs and decrease
power quality problems. Small investments
in Intermatic energy controls and surge
protection can:
• Increase energy savings
• Increase up-time
• Increase productivity
• Increase data retention
Whether it’s part of a manufacturing,
distribution or office environment,
Intermatic offers a broad line of
commercially related products for:
• High amperage/voltage machinery
• Heavy duty pumps
• Motors
• Variable frequency drives
• HVAC systems
In addition to a broad range of products,
Intermatic provides complete bid
specifications and wiring diagrams for every
model and each product is backed up by the
industry’s best sales support and technical
assistance team.
™ For more than a century, Intermatic has been a premier supplier of commercial and industrial products and has
Z-WAVE
developed a reputation for providing its customers with innovative products that far exceed their expectations. The new InTouch
Wireless Controls™ line of home controls will serve as the primary link to the Intermatic System. Brought to life with Z-Wave™
technology, InTouch Wireless Controls™ will help our customers grow their business within the booming home controls industry
and will help home and business owners achieve higher levels of convenience, security and safety.
7
Residential Applications
Whether you’re an electrical contractor, homebuilder or homeowner, Intermatic is the only name
you need to know for increased levels of convenience, safety, security and electronic protection.
Intermatic Residential Applications
•
•
•
•
•
•
•
•
Interior and exterior lighting control
Whole home energy controls
Whole home surge protection
Home office and home theatre surge
protection
Pool and spa controls
Landscape lighting
Exterior receptacle protection
Security floodlighting
With electricity costs on the rise and power
quality problems at an all time high,
Intermatic has a full line of residential
products needed to combat these issues. A
minor investment in energy controls and
surge protection can prove to have major
long-term cost savings and home
appliance/electronic preservation. Intermatic
residential products provide homeowners
with multiple benefits, including:
• Whole home energy savings
• Lighting automation to increase the
beauty, Safety and security of your home
• Surge protection for home appliances and
electronics
• Landscape lighting to accent your home
and property
• Pool and spa controls for improved cost
savings and convenience
Intermatic provides the home building
industry with the most comprehensive
offering of residential energy control and
surge protection products. Intermatic also
offers weatherproof products, pool and spa
controls and low voltage landscape lighting.
Intermatic products can be used through a
home and the surrounding property,
including:
• Garages and outbuildings
• Landscaping
• Entrances
• Kitchens and bathrooms
• Home offices and entertainment centers
• Pool and spas
Intermatic has developed two marketing
programs to benefit those within the
residential market:
• Intermatic Authorized Installer
Program helps contractors up-sell during
a service call.
• InGenius Homebuilder Program helps
builders of new homes increase their
add-on opportunities.
Z-WAVE™ The future of the digital home is closer than we realize. Intermatic has a growing list of home control products that
work together to enhance the safety, security and convenience of our complex and eventful lives. Intermatic has the knowledge,
ability and resources to revolutionize home automation.
8
9
Intermatic provides you with everything you
need in order to draw, secure and maintain
steady sales growth
Opportunities include:
• Advanced Sales Support
• Sales Incentives
• Sales Training
• Sales Programs and Promotions
• Merchandising
• Interactive Web Site
The Industry’s Best Sales Support
Our distributor sales training includes ways to best
merchandise and up-sell our wide array of products.
Training takes place at local, regional and national trade
shows. In addition, Intermatic holds regular counter days
and product “lunch and learns,” hosted by our direct
sales personnel and sales agents, on location at local
distributors.
Call 800-391-4555 for toll-free technical support and
assistance with programming, installation or application
questions. Intermatic also works with engineers and
specifiers and holds seminars for them on InTouch
Wireless Controls™, surge supression products and Next
Generation time switches. Contact your local Intermatic
sales representative or visit www.intermatic.com.
Intermatic’s order service support is set up to allow
distributors and OEM customers to receive product
when, where and how they want it. Drop shipments,
multi-location shipments, blanket orders, express
shipping and ship complete orders are complemented by
a variety of other order support services. Our highly
trained customer service representatives can also provide
you with support for technical questions and applications
by calling 815-675-7000 between 8:00 a.m. and 4:30
p.m. CST, Monday through Friday.
10
Intermatic Merchandising/Support
Customized Sales Incentives
Regular sales spiffs for sales and
counter personnel are designed to
motivate the seller and push product at
every level. Customized sales support
literature can also be designed for local
made-to-order programs.
Motivational Sales Programs and
Promotions
Intermatic is a total business partner
and backs the sale of its products with
innovative programs and promotions at
every level, with support provided to
distributors, contractors and home
builders.
Merchandising items include:
• Plan-o-grams
Comprehensive Sales Training
Providing you with the industry’s best
electrical products is step one. Helping
you get those products into the hands
of your customer is step two. The best
way to make that happen is to supply
you with specific information on how
to sell and up-sell within our five
categories of products. On site or at the
counter, Intermatic gives you the
answers to frequently asked questions
and provides you with good, better and
best scenarios and competitive comparisons in order to help you help your
customers make the best buying
decision.
• The Power-Plus Program for
distributors increases their margins
and inventory turns while lowering
their transaction costs.
• Banners
• The Authorized Installer Program
helps contractors add to their bottom
line by up-selling and installing
additional products during service
calls.
• The InGenius Program helps home
builders sell upgrades at model
homes and in the sales office.
• Header cards
• Floor, wall and counter displays
• Self shipper displays
• P.O.P. displays
• Countermats
• Spec and cross reference CDs
• Product demo and literature CDs
Interactive Web Site Marketing
Intermatic’s e-marketing program
utilizes the Internet to provide fast,
efficient, 24/7 communications with
both distributors and end users.
Intermatic’s Web site includes:
• Authorized distributor locator
• Authorized installer locator
Intermatic also provides a regular
selection of promotions that include
shipper/displays, product introductions,
contractor bonus packs and Intermatic
branded merchandise.
• Downloadable specifications, wiring
diagrams and instruction manuals
• E-mail technical support
• General catalog (downloadable PDF)
• Warranty registration
Thought-provoking Merchandising
Eighty percent of walk-in customers
will buy additional products, if
merchandising is done effectively.
Sixty-five percent of all purchases are
affected by displays and visual
graphics. That is why Intermatic has
invested heavily in merchandising
resources in order to boost your return
on investment. Intermatic’s Industrial
Merchandising program provides you
with the support and information you
need to achieve maximum results,
increase impulse purchases and build
effective displays.
In the future, a variety of
enhancements will be implemented that
will include improved navigation,
product search by category or model
number, competitive product search,
ordering of product literature and an
events/news page. Also, a new
secured-access distributor intranet will
provide additional product education
and sales training, distributor spec
sheets, pricing and promotions, a
job-quoting tool and a discussion
board.
For more information on Intermatic sales support, programs and promotions, contact your
local Intermatic sales representative, visit www.intermatic.com or call 815-675-7000
between 8:00 a.m. and 4:30 p.m. CST, Monday through Friday.
11
Five reasons to keep your eye on Intermatic
Superior New Product Developments
Intermatic is able to leverage its global and technological
resources to provide its customers with products full of
innovative features and benefits and maintain its
first-to-market stature.
World-class Global Manufacturing
The Intermatic family is made up of a global workforce, who
through lean manufacturing methods, produce the world’s
finest energy control products.
Excellent Supply Chain Management
Regardless of its substantial growth, Intermatic has remained
flexible and responsive and completely customer focused. At
Intermatic, intensive quality control and on-time deliveries are
customary.
Complete Sales and Marketing Support
Over the course of the year, Intermatic helps promote its
products through a variety of sales incentives, promotions and
merchandising campaigns. We also offer distributor training
and technical support at every level.
Superior Enterprise Information Systems
Flexible, Web-based information gives us a competitive
advantage and real-time information keeps us up to date to
help take better care of our customers.
12
Your Outdoor Needs are Covered
Often times, the simplest things in life
make the biggest impact. Intermatic
understands that simple measures
can have a big effect in protecting
the electrical systems and
products within your home or
business.
Intermatic has designed a
line of hard wearing
weatherproof products that
provide an exact match to
the application, are easy
to install and provide
reliability and longevity.
Our full line of
weatherproof products
are the perfect
combination of utility
and innovation. From
our patented Flexi-Guard
covers to our heavy duty
die-cast outlet boxes, lamp
holders and fittings,
Intermatic has you completely
covered from start to finish.
Intermatic also makes it easy to
stay current with the latest electrical
codes and all models comply with
2002 NEC Article 250.146, which
provides direct mounting of wiring devices
to the switch box. We have the best coverage
in the industry and are constantly updating our
product categories to meet your ever-changing needs
and requirements. As new codes and articles are being
introduced and enforced, Intermatic will have the box, cover
or accessory you need to remain compliant.
13
Weatherproof Receptacle Covers with Patented Insert Design
These NEMA 3R receptacle covers ensure compliance with 2005 NEC Article 406.8 (B) (1) which requires that
15 and 20 ampere, 125 and 250 volt receptacles installed in a wet location have an enclosure that is
weatherproof whether or not the attachment plug cap is inserted. They also meet the 1999 NEC Article
410-57(b) and are designed to meet the 1999 NEC Article 210-60(b), which requires that receptacles installed
behind beds in hotels and motels be protected with a suitable guard.
All covers are shipped with gasket, mounting screws, base and cover assembly and patented inserts. The
Flexi-Guard series provides inserts for a variety of applications; 16 for the WP3100/WP1100 single gang
series and 70 for the WP1200 two gang series. The single gang Flexi-Guard models are all designed to mount
horizontally or vertically. The patented insert design ensures flexibility in the field by simply inserting the
proper insert into the base and cover assembly. The two gang Flexi-Guard models utilize six “split” inserts
which create virtually any dual device combination, as well as providing additional flexibility because the
inserts can be rotated 90, 180 or 270 degrees. This provides coverage for horizontally or vertically mounted
devices as well as “left hand” or “right hand” applications without removing and switching the two installed
devices.
The “jumbo covers” WP1150C, WP1250C, WP1050 and WP1050G provide protection for a single large cord
set (up to 3/4" dia.) for portable spa heaters and other heavy duty applications. A lockable hasp is provided
on selected models. The hasp accepts up to .315" (8 mm) diameter shank.
NEMA 3R
Meets UL and CSA Cold Impact Testing at -60˚F (-51˚C)
Patented:
U.S. Patent #5 280 135
U.S. Design Pat. #342233
Canadian Patent #2 073 932
Other Patents Pending
Waterproof Cover Applications
• Vending Machines
• RV Connectors
• Sprinkling Controls
• Car Lot Lighting
• Car Washes
• Food Preparation
• Hotel Applications
• Amusement Equipment
• Seasonal Lighting
• Drinking Fountains
• Gate Controls
• Low Voltage Lighting
• Plant Grow Lighting
• Scoreboard Controls
• Ventilating Fans
• Remote Power Needs
• Athletic Field Lighting
• Process Start Up
• Meat Processing
• Plant Watering
• Landscape Lighting
• Portable Spas
• Score Board Controls
• Equipment
• Engine Block Heaters
• Remote Feeders
• Outdoor Signs
• Portable Marquee
• Bug Zappers
• Septic Lift Pumps
• Holiday Lighting
• Irrigation Pumps
Specifications
All covers for flushmount, surface mount or FS junction box mounting.
Cover – Clear (gray or white on selected models) UV stabilized polycarbonate with two cord outlets 1/2"
(12.7 mm) Wide by 9/16" (14.2 mm) High. Models WP1150C, WP1250C and WP1050 one cord outlet 3/4"
(19.1 mm) Wide by 1-5/16" (33.3 mm) High.
Mounting Base and Inserts – Black UV stabilized polycarbonate.
Gasket – Neoprene - 1/8" (4.8 mm) thick with slits for mounting screws.
Shipping Weight – WP3100C – .45 lbs. (0.20 kg)
WP1100C / WP1000HC – .38 lbs. (0.17 kg)
WP1110C / WP1010HC – .41 lbs. (0.19 kg)
WP1150C / WP1230C / WP1030C – .75 lbs. (0.34 kg)
WP1220C / WP1020C – .72 lbs. (0.33 kg)
WP1250C / WP1050 – .9 lbs. (0.41 kg)
UL514D
E142193
14
C22.2-42.1
LR88576
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Weatherproof Receptacle Covers with Patented Insert Design
WP3100C - Vertical/Horizontal Cover
Flexi-Guard Weatherproof While-In-Use Cover
Product Features
• Complies with 2005 NEC® Article 406.8(B)(1): “15 and 20 Ampere, 125 and 250V receptacles installed in wet
locations shall have an enclosure that is weatherproof whether or not the attachment plug cap is inserted”
• Easy to remove cord set exit ports
APPLICATIONS
Provides an attractive, code compliant solution for protecting while-in-use outdoor receptacles.
SPECIFICATIONS
• Mounts Vertically or Horizontally
• Hidden Hinges
• Three patented inserts for GFCI, Duplex, Toggle and Single Receptacles
• Inserts include keyhole slots for 16 installation configurations
• Pre-adhered gasket
• Heavy-duty polycarbonate construction
• Clear Cover
• Gray Base
• Meets requirements for cold impact testing at -60º F (-51ºC)
• Lockable hasp for 1/8” shank lock
GFCI DEVICE SHOWN NOT INCLUDED
Warranty: Limited 1-year warranty
1.00 lbs
0.45 kg
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
15
Weatherproof Receptacle Covers with Patented Insert Design
WP1000RC - Vertical Cover
WP1000HRC - Horizontal Cover
Recessed Weatherproof While-In-Use Cover
Product Features
• Complies with 2005 NEC® Article 406.8(B)(1)
• Heavy duty, polycarbonate cover for long lasting durability
APPLICATIONS
Provides an attractive, code compliant solution for protecting while-in-use
outdoor receptacles.
GFCI DEVICE SHOWN NOT INCLUDED
SPECIFICATIONS
• Device installs recessed in wall for a flush finish for Siding, Stucco or
Brick finishes
• Removable siding flange provides clear finish for all siding types
• Patented single gang inserts for GFCI, duplex, single receptacles,
toggle switch and blank
• Heavy Duty Gasket ensures protection from the elements
• Recessed Sleeve adjusts to ensure lowest profile installation in every application
• Outlet box offers mounting options for stud, block, brick or cut-in
• Cord exit easily handles two 12/3 cord sets
• Handles romex or conduit installations
• Wider access to device for easy cord set installation
• Heavy duty, UV resistant, polycarbonate constructed cover
2.00 lbs
0.91 kg
Warranty: Limited 1-year warranty
WP2000 Flexi-Guard Outlet Post
Weatherproof While-In-Use Cover
PRODUCT FEATURES
• Complies with 2005 NEC® Article 406.8(B)(1)
• Heavy duty PVC construction for long lasting durability
APPLICATIONS
Provides a new, code compliant solution for supplying power to gardens and other out-of-the-way areas.
A remotely mounted energy saving photo control and/or timer also available to activate area lighting
SPECIFICATIONS
GFCI DEVICE SHOWN NOT INCLUDED
• Patented single gang inserts for GFCI, duplex, single receptacles, toggle switch and blank
• Provisions for installing mechanical or digital timers to control area lighting:
– PB912M10R: 24 hour, 120 Volt mechanical timer – allows for 2 ON/OFF daily cycles
– PB313K: 24 hour, 120 Volt electronic timer – allows for 8 ON/OFF daily cycles (Timers sold separately)
• Provisions for fixed-position, stem-mounting and stem & swivel mounting photo controls to control area lighting
• All ports accept 1/2”,3/4”, or 1” PVC conduit (adapters included)
• Base includes mounting holes and template for optional concrete/pavement mounting
• Cover includes lockable hasp
Warranty: Limited-1 year warranty
3.00 lbs
1.36 kg
16
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Weatherproof Receptacle Covers
Die Cast
These heavy duty die cast receptacle covers ensure compliance with the National Electrical Code (NEC). These
models offer the same features as the plastic models but are manufactured of heavy duty cast metal for severe
applications such as schools and commercial buildings. The two gang model WP1030MC includes inserts
for double gang duplex and GFCI requirements. This patented insert design uses the same inserts as all
WP1000 series weatherproof covers and provides flexibility in the field by selecting and inserting the proper
insert. For other applications see insert listing below.
All models are recommended for 14 gauge or lighter cord sets. A lockable hasp is provided (lock not
included). The hasp accepts up to .315" (8 mm) diameter shank.
Specifications
Cover – Gray die cast metal
Mounting Base – Gray die cast metal with cord outlets 1" (25.4 mm) Wide by 5/8" (15.9 mm) High; one
for models WP1010MC and WP1010HMC and two for model WP1030MC.
Inserts – Black UV stabilized polycarbonate.
Gasket – Neoprene 1/8" (3.2 cm) thick with slits for mounting screws.
Shipping Weight – WP1010MC – 0.8 lbs. (0.36 kg)
WP1010HMC – 0.9 lbs. (0.41 kg)
WP1030MC – 1.1 lbs. (0.5 kg)
All models comply with 2005 NEC Article 250.146 which provides direct mounting of wiring devices to the switch box.
UL514D
E142193
C22.2-42.1
LR88576
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
17
Now you can handle even more with less.
Inserts
Inserts fit single gang models and two gang
models of clear, gray or die cast design. The
2-gang inserts for models WP1020, WP1030,
WP1020GC, WP1030GC, WP1030MC and WP1050
can be mounted at any angle 90, 180 or 270
degrees from that shown. Additional hardware, if
required, and special 2-gang gasket is packaged
with 2-gang (WP200 series) inserts.
16 Configurations for
Single Gang WP1100C Series
Intermatic Flexi-Guard Weatherproof Receptacle Covers let you handle even more configurations with fewer
units. The unique patented inserts and covers allow you to keep even less inventory than before, and cover
more jobs out in the field.
Our single gang models handle both vertical or horizontal applications, just by changing the hinge points. Our
two-gang models include snap-together, rotating inserts that create combinations for almost every application.
With these new Flexi-Guard models, now more than ever, Intermatic is the best NEC code solution under the
sun.
New Features
Single gang plastic models feature pre-adhered gaskets and all covers feature keyhole slots on inserts
for the quickest installation available
Clear & Opaque Gray Models
70 Configurations for Double
Gang WP1200C Series
3-1/2"
2-5/8"
WP1010
3-1/2"
WP1000
2-5/8"
WP1030/WP1230C
3-1/2"
WP1020/1220C
2-5/8"
WP1050/WP1250C
4-1/4"
5-1/2"
5-1/2"
4-7/8"
WP1010H
WP1000H
6"
5"
3-13/16"
5"
5"
Clear & White Models
4-3/4"
3-1/2"
2-7/8"
4-7/8"
WP1030/WP1230C
3-1/2"
WP1020/1220C
2-5/8"
WP1150C
WP1110C
WP1100C
WP1050/WP1250C
6"
5-1/2"
5-3/8"
5"
5"
3-1/2"
Heavy Duty Die Cast Models
3-1/4"
2-1/2"
3-1/4"
2-1/2"
WP1030MC
3-1/4"
2-1/2"
WP1010MC
WP1010HMC
4-1/2"
6-1/2"
6-1/2"
Additional inserts available for
Flexi-Guard or Guardian Series
5-3/4"
3-3/4"
5-9/16"
Outlet Post
Recessed
WP2000
FRONT VIEW
BOTTOM VIEW
Two
Gang
Duplex
Two
Gang
GFCI
Two
Gang
Toggle
Two
Gang
Round
Two
Gang
Round
WP101
WP102
WP103
WP107
WP213
SIDE VIEW
6-5/8” DIA
WP1000RC
6.81
5.47
1.125
WP1000HRC
6.0
1.125
8.62
0.25
1.125
7.25
6.0
1.125
0.25
3.50
3.50
1-13/32”
9.43”
7.70
1-13/32”
5.90
5.88
6.81
8.62
WET LOCATIONS ONLY WHEN COVER CLOSED
1-13/32”
1-3/8”
1-5/8”
1-3/4”
Single Gang Flexi-Guard
WP17
† Converts to toggle,
1-3/8", 1-5/8",
1-3/4" or 2-1/8"
diameter round
18
2-5/32”
2-21/32”
1-5/8”
WET LOCATIONS ONLY WHEN COVER CLOSED
1-13/32”
1-5/8”
6.64”
8.17”
Two Gang Flexi-Guard
WP217
‡ Converts to toggle,
1-3/8" or 1-5/8"
diameter round
Inset Design US Patent #5 280 135
Canadian Patent #2073932
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Now you can handle even more with less.
Patented Single Gang
Vertical or Horizontal
2-1/4”
Standard
Depth
2-3/4”
Standard
Depth
Two Gang with Patented
Patented Die Cast Metal
Snap-Together Inserts
Clear
WP1220C
Patented Two Gang
Fixed
Patented Single Gang
Fixed
Clear
WP1020C
Clear
Gray
WP1000C WP1000GC
Vertical
Vertical
WP1000HC WP1000HGC
Horizontal* Horizontal*
Clear
WP1030C
Clear
WP1010C
Vertical
WP1010HC
Horizontal*
Clear*
White*
WP1100C WP1100WC
Vertical or Horizontal
3-1/8”
Standard
Depth
3-5/8”
Standard
Depth
Grey Die Cast
WP1010MC Vertical
Single Gang
Clear
WP1230C
WP1030MC Two Gang
WP1010HMC Horizontal
Single Gang
Clear*
White*
WP1110C WP1110WC
Vertical or Horizontal
4-3/4”
Standard
Depth
Clear*
WP1150C
Clear*
WP1250C
Clear*
WP1050
Vertical or Horizontal
WP1100 Series
Includes 3 Patented
Inserts
WP1200 Series
Includes 6 Snap
Together Patented
Inserts
WP1000MC Series
Includes these Patented
Inserts
‡
WP1000 Series
Includes these Inserts
WP1000 Series
Includes these Inserts
‡
Two Gang
†
†
†
‡
Single Gang
*
†
‡
With lockable hasp
Converts to toggle, 1-3/8”, 1-5/8”, 1-3/4” or 2-1/8” diameter round
Converts to toggle, 1-3/8” or 1-5/8” diameter round
Insert Design US Patent #5 280 135
Canadian Patent #2073932
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
19
Giving You Total Control
Within both home and work environments,
Intermatic has been a leader in
innovation for timing, switches and
energy controls for more than 110
years. Intermatic provides the
industry’s broadest line of energy
controls, with ratings and
innovative features designed to
handle any industrial,
commercial or residential
application.
Presently, the home controls
industry is growing at an
annual rate of 18 percent.
Additionally, industry
experts predict that the
category of home controls
could approach annual sales
of $500 million. Intermatic
sees this as a wonderful
opportunity, not only to grow
our business, but help you
grow yours as well – through
the best product offerings,
programs and support at every
step of the way.
20
Photo Controls
A full line of thermal type photo controls and relay type photo controls provide “dusk-to-dawn” lighting
control. The thermal type controls feature a cadmium sulfide photocell and sonic welded polycarbonate case
and lens to seal out moisture. The design utilizes a dual temperature compensating bimetal and a metal film
resistor for reliable long life operation over ambient temperature extremes. The thermal type photo controls
provide a delay action which eliminates loads switching OFF due to car headlights, lightning, etc.
K4021C
Applications
• Parking Lot Lighting
• Billboard Lighting
Model
K4321C
UL773A
E42722
C22.2-55
LR38068
• Area Lighting
• Municipal Lighting
K4000
Series
UL773A
E42722
• Car Lot Lighting
• Roadway Lighting
• Security Lighting
• Street Lighting
5 Year
Warranty
Fixed Position Mounting, Thermal Type — K4000C Series
Designed to fit into a standard outlet box, a post lamp or wall packs. Model K4321 includes a weatherproof
wall plate with neoprene gasket. The UL listing for this model applies to the entire plate assembly when
properly mounted to an approved outdoor junction box. All other models are equipped with a 3/8"-18
threaded side mounting, locking nut and washer gasket. All models with 9" leads.
Size – Plate - 4-1/2" (11.4 cm) High, 2-3/4" (7.0 cm) Wide;
Mechanism - 1-5/16" (3.3 cm) W, 1-13/16" (4.6 cm) L, 13/16" (2.1 cm) D.
K4321C
Model #
Watts Tungsten
VA Ballast
Amps Tungsten
Amps Ballast
Volts
K4021C
K4023C
K4024
K4022
K4033
K4027***
K4035*
K4321C**
1800
3100-4150
3100
3600
4150
5205
7200
1800
1000
1700-2300
1700
2000
2300
2880
4000
1000
15
15
15
15
15
15
15
15
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
120
208-277
208
240
277
347
480
120
Note: Wall plate with gasket available for other models; order No. K4001.
* Not UL listed or CSA certified.
** Wall plate included.
*** Certified by CSA to US and Canadian Standards.
Specifications
Unless noted otherwise, the specifications listed below apply to K4000, K4100, K4200, K4300 & K4500
Series.
Size – See individual models. Most hard wired models supplied with 6" leads. K4000 fixed position models
have 9" leads.
Switch Rating – See chart for each series. Note that the ballast wattage rating is based upon a 50% power
factor.
Activation – 1 - 5 FC “ON”; 3 - 15 FC “OFF” (without shield on models with shield.)
Color – Gray
Shipping Weight – See individual models.
Light Shield for K4000
Part Number 6LV1352
UL773A
E42722
C22.2-55
LR38068
K4000
Series
UL773A
E42722
5 Year
Warranty
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
21
Photo Controls
Stem Mounting, Thermal Type – K4100 Series
K4121C
This series features single and multivolt models in both stem mount and stem mount with a swivel. All models
are equipped with a light level slide adjustment and provide a 1/2"-14 threaded stem. A washer gasket and
locking nut are packaged with each photo control. Models with “M” suffix have heavy duty die cast housings.
Model K4251 and K4253 have photo eye located on top and are designed for spot/flood type fixtures.
Size – K4100 Series - 1-9/16" (4.0 cm) Square, 3" (7.6 cm) Long;
K4200 Series - 1/2"-14 threaded swivel, 1-9/16" (4.0 cm) Square, 5-1/2" (14.0 cm) Long;
Model K4236 - 5-3/4" (14.6 cm) High, 3" (7.6 cm) Diameter.
Model #
K4121M
K4423M
Watts Tungsten
VA Ballast
Amps Tungsten
Amps Ballast
Volts
1800
2000
1800
3100
3600
3100-4150
3100-4150
4150
5205
7200
2000-4625
3000
1000
1800
1000
1700
2000
1700-2300
1700-2300
2300
2880
4000
1800
3000
15
16.7
15
15
15
15
15
15
15
15
16.7
25
8.3
15
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.6
25
120
120
120
208
240
208-277
208-277
277
347
480
120 or 277
120
K4121C
K4121M
K4421M
K4124
K4122
K4123C
K4423M***
K4133
K4127****
K4135*
K4136M
**K4141C*
* Not UL listed or CSA certified.
** 1 year warranty.
*** Model K4423M replaces K4123M
**** Certified by CSA to US and Canadian Standards.
UL773A
E42722
C22.2-55
LR38068
5 Year
Warranty
K4221C
Stem & Swivel Mounting, Thermal Type – K4200 Series
K4236C
Model #
Watts Tungsten
VA Ballast
Amps Tungsten
Amps Ballast
Volts
K4221C
K4224
K4222
K4223C
K4233
K4227***
K4235*
K4236C
K4251***
K4253***
1800
3100
3600
3100-4150
4100
5205
7200
1800-4150
1800
3100-4150
1000
1700
2000
1700-2300
2300
2880
4000
1000-2300
1000
1700-2300
15
15
15
15
15
15
15
15
15
15
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
120
208
240
208-277
277
347
480
120 or 208-277
120
208-277
* Not UL listed or CSA certified.
***Certified by CSA to US and Canadian Standards.
K4251
22
UL773A
E42722
C22.2-55
LR38068
5 Year
Warranty
C22.2-177
LR3730
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Photo Controls
Locking-Type Mounting, Thermal Type — K4500 Series
Easy to install; just plug in and twist. This series is equipped with standard 3-prong NEMA locking-type plug
connections. Incorporates K4000 style thermal switch for reliable long life performance. Complies with ANSI
C136.10.
Size – 3-3/4" (9.5 cm) High, 3" (7.6 cm) Diameter.
Model #
Watts Tungsten
VA Ballast
Amps Tungsten
Amps Ballast
Volts
K4521
K4524**
K4522
K4533**
K4535**
1800
3100
3600
4100
7200
1000
1700
2000
2300
4000
15
15
15
15
15
8.3
8.3
8.3
8.3
8.3
120
208
240
277
480
* Ballast rating meets UL testing at 50% power factor.
** Not CSA certified.
UL773
E59121
C22.2-177
LR38068
3/4 lbs
.34 kg
K4521
5 Year
Warranty
Accessories for Locking-Type Controls
Pole Bracket Adapter – Model K122 - 105 to 480 Volts; for use with K1200, K4500 or LC4500 Series
locking-type controls. K121 – receptacle only, K121-30 receptacle with 30 inch leads.
Shorting Cap – Model K4500 - 105 to 480 Volts; replaces locking-type photo control to complete circuit.
K4500
K122
K121
K121-30
Low Cost Locking-Type, Thermal Type — LC4500 Series
The LC4500 Series provides low cost reliable control for street lighting and other applications requiring a
NEMA twist and lock type plug connection. An integral housing and lens, with UV protection, keeps moisture
out and ensures long life. Complies with ANSI C136.10.
Activation – .5 FC minimum “ON”; 15 FC maximum “OFF”.
Size – 2-3/4" (7.0 cm) High, 3" (7.6 cm.) Diameter.
Color – Translucent with color coded band for voltage identification.
Model #
Watts Tungsten
VA Ballast
Volts
1000
1700-2300
5205
1000
1000-2300
1000
1700-2300
1000
1000-2300
1000
1700-2300
2880
4000
1000-2300
1000
1700-2300
4000
1000-2300
120
208-277
347
480
120 or 208-277
120
208-277
480
120 or 208-277
LC4521C
LC4523
LC4527
LC4535**
LC4536C
LC4521LA
LC4523LA
LC4535LA**
LC4536LAC
LC4521C
LA Models equipped with 2400 volt open type spark gap arrester.
* Ballast rating meets UL testing at 50% power factor.
** Not CSA certified.
UL773
E59121
C22.2-55
LR38068
.2 lbs
.09 kg
3 Year
Warranty
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
23
Photo Controls
Relay Type Photo Controls With Adjustable Stem or Locking-Type Mounting —
K1100, K1200 Series
This series features “instant ON/OFF switching” in two mounting types. Complies with ANSI C136.10.
K1200
Series K1100 – Equipped with an adjustable stem for mounting at almost any angle up to 80 degrees.
Models equipped with three 6" color coded leads.
Series K1200 – Easy to install using NEMA plug-in locking type connection. Models are equipped with
2400 Volt open type spark gap arrester and standard 3-prong connector.
Size - K1100 Series – 5-3/4" (14.6 cm) High, 3" (7.6 cm) Diameter; 1/2"-14 NPT Stem;
K1200 Series – 3-3/4" (9.5 cm) High, 3" (7.6 cm) Diameter.
Activation – 1 FC “ON”; 3 - 10 FC “OFF”
Model #
Watts Tungsten
VA Ballast
Volts
1800
1800
1800
1800
1800
1800
1800
1800
105-130
210-240
105-130
210-240
K1121
K1122
K1221
K1222
* Ballast rating meets UL testing at 50% power factor.
K1100
UL773
E59121
C22.2-55
LR38068
3/4 lbs
.34 kg
5 Year
Warranty
UL773A
E42722
Low Cost Relay Type Photo Control with Locking-Type Mounting — LC2000
Features “Instant ON/OFF Switching”. Complies with ANSI C136.10
Size - 2-3/16" (5.6 cm) High, 3-3/16" (8.1 cm) Diameter
Activation – 1 to 3 FC “ON”. Turn OFF to turn ON ratio is 4.
LC2000
Model #
Watts Tungsten
VA Ballast
Volts
LC2000
1000
1800
110-277
Includes 110 Joule MOV Surge Arrester.
UL773
E59121
24
3/4 lbs
.34 kg
3 Year
Warranty
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Photo Controls
Solid State Photo Controls - Locking Type
The K4536SS Photo Control is electronically calibrated and provides reliable control of street lighting and
other applications requiring a NEMA plug-in locking type connection. Complies with ANSI C136.10.
The K4536SST is the same as above, but provides a fixed “OFF” time adjustable in half hour increments from
6:00 PM to 2:00 AM and a fixed “ON” time adjustable in half hour increments from 4:00 AM to 8:00 AM.
The fixed times are based on a real-time clock that sets itself based on the occurrence of sunrise and sunset.
Operation – Instant “ON”, 10 Second Delay “OFF”
Size - same as LC4500 Series
Color - same as LC4500 Series
Model #
Watts Tungsten
VA Ballast
Volts
K4536SS
K4536SST
1000
1000
1800
1800
105-305
105-305
Includes 430 Joule MOV Surge Arrestor.
UL773A
E42722
3/4 lbs
.34 kg
K4536SS
5 Year
Warranty
K4536SST
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
25
Time Switches
24 Hour Dial
T100 Series – Designed for industrial, commercial and residential applications. Highest HP ratings in the
industry for loads up to 40 amps, providing direct 24 hr. control of most loads. Provides 1 to 12 “ON/OFF”
operations each day with minimum ON/OFF times of 1 hour. All models equipped with one “ON” and one
“OFF” tripper.
Applications
• Indoor/Outdoor Lighting
• Signs
• Filters
• Air Conditioning
• Electric Fences
• Heating/Ventilating Systems
• Fans
• Conveyers
• Post Lanterns
• Pool Heaters
• Hydrochlorinators
• Blowers
• Pumps
• Music and Signal Systems
• Poultry Foggers
Specifications
Case – Drawn steel 7-3/4" (19.7 cm) H, 5" (12.7 cm) W, 3" (7.6 cm) D in gray finish. Spring hasp, with hole
for lock, holds permanently attached, side hinged door closed. Three mounting holes on back plus handy
box mounting holes.
Knockouts – Combination 1/2"–3/4" nominal knockouts, one on back and each side of case and two on
bottom.
Optional Enclosures – See Time Switch Cases page for optional enclosures.
Special Voltages and Cycles – See Time Switch Motors page for available motors.
Switch Rating – Each Pole; 40 Amp Resistive, 120-480 VAC; 40 Amp Tungsten, inductive or 1000 VA pilot
duty, 120-277 VAC; 2 HP (24 FLA) 120 VAC; 5 HP (28 FLA) 240 VAC single phase; 7-1/2 HP (28 FLA) 208
VAC three phase; 10 HP (28 FLA) 240 VAC three phase.
Model #
Model #
w/See-Thru Cover
Model #
Plastic Case
Model # Steel
NEMA 3R Case
T101
T102
T103
T104
T101B*
T105
T106R†
T101PCD82
––
T103PCD82
T104PCD82
––
––
––
T101P
T102P
T103P
T104P
––
––
––
T101R
T102R
T103R
T104R
Switch
Clock Motor
Volts 60 Hz
AMPS
(per pole)
HP Rating
SPST
SPST
DPST
DPST
SPST
1NO / 1NC**
1NO / 1NC**
125
208-277
125
208-277
125
125
208-277
40
40
40
40
40
40
40
2
5
2
5
2
2
5
* Separate clock motor terminals for switching circuits not on line voltage.
** Can be wired as SPDT.
† Only available in NEMA 3R case.
For additional trippers (1 ON / 1 OFF per pack), order No. 156T1978A.
C22.2-177
LR3730
UL917
26
2.75 lbs
1.25 kg
-40°F
(-40°C)
to
130°F
(54°C)
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Time Switches
24 Hr. w/Skipper, Optional Carryover
T170 Series – Same features as the T100 Series plus a skipper option to omit operation on selected days.
Cutout screws are inserted in the dial for days which operation is to be skipped. Provides up to 10 ON/OFF
operations each day with min. ON/OFF operations of 1 hour and max. ON time of 20 hours. Includes one
CUTOUT tripper (also serves as an “ON” tripper), one “OFF” tripper and three skipping screws.
T170CR Series – Same features as the T170 Series Skipper models plus a min. of 16 hours carryover for
maintaining preset schedules during power failures. Carryover automatically rewinds when power resumes;
only one hour of rewinding time required for every two hours of power outage. 4PST models are ideal for
3-phase load control.
Specifications
Case – T170 Series same as T100 except as noted under Optional Enclosures. T170CR only in NEMA 3R
drawn steel 9-3/8" (23.8 cm) H, 5-1/2" (14.0 cm) W, 3-5/8" (9.2 cm) D in gray finish. Hasp, with hole for
lock, holds permanently attached, side-hinged door closed. Bracket plus two holes on back below switch
for mounting. Separate grounding terminal.
Optional Enclosures – 4 pole and 2 NO/ 2 NC models not available in standard or plastic case; only in
NEMA 3R steel case. T170CR only available in steel NEMA 3R enclosure.
Special Voltages and Cycles – See Time Switch Motors for available motors. Contact factory for
availability of time switch with 50 cycle or other voltages.
Special Voltages and Cycles – Same as T100 Series.
Switch Rating – Same as T100 Series.
Model #
T171
T172
T173
T174
T175
T176
T1471BR*
T1472BR*
T1475BR*
T1871BR*
T171CR
T173CR
T174CR
T1471BCR*
Model # Steel
NEMA 3R Case
T173R
T174R
Switch
Clock Motor
Volts 60 Hz
AMPS
(per pole)
HP
Rating
SPST
SPST
DPST
DPST
1NO / 1NC**
1NO / 1NC**
4PST
4PST
4PST
2NO / 2NC***
SPST
DPST
DPST
4PST
125
208-277
125
208-277
125
208-277
125
208-277
480
125
125
125
208-277
125
40
40
40
40
40
40
40
40
40
40
40
40
40
40
2
5
2
5
2
5
2
5
5
2
2
2
5
2
C22.2-177
LR3730
UL916
-40°F
(-40°C)
to
130°F
(54°C)
2.75 lbs
1.25 kg
Same as
T100
Series
* Separate clock motor terminals for switching circuits not on line voltage.
** Can be wired as SPDT.
*** Can be wired as DPDT.
For additional trippers (1 ON / 1 OFF / 1 CUTOUT per pack), order No. 156T1948A.
For additional skipper screws (3 skipper screws per pack), order No. 156T3085A.
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
27
Time Switches
Portable
This portable cord connected time switch performs all the functions of the T100 and T170 series time switches
plus it is completely portable eliminating the need for wiring. Supplied complete with 6' grounded cord set and
receptacle installed.
Applications (Indoor Only)
• Photo Copiers
• Electric Water Heaters
• Ventilating Systems
• Portable Lights
• Air Conditioning
• Motors
• Signs
• Fans
• Pumps
• Space Heaters
• Poultry Foggers
• Blowers
Specifications
Case – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in gray finish. Spring hasp,
with hole for lock, holds permanently attached, side hinged door closed. Three mounting holes on back
plus handy box mounting holes.
Knockouts – Not applicable; prewired cord and receptacle.
Switch Rating – 15 Amp Resistive, 15 Amp Tungsten; 345 VA pilot duty (15 FLA), 125 VAC.
G
W
Model #
Switch
Clock Motor Volts 60 Hz
Amps (per pole)
Skipper Wheel
P171-30
SPST
125
15
Yes
For additional trippers Model Series P170 (1 ON/1 OFF/1 CUTOUT per pack), order No. 156T1948A.
120V - 15A Receptacle
C22.2-177
LR3730
UL917
28
3 lbs
1.36 kg
-40°F
(-40°C)
to
130°F
(54°C)
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Time Switches
24 Hour Dial w/Skipper
The T1900 Supervisor Series provides up to 96 operations (48 ON /48 OFF) every 24 hours. This series
provides operations with minimum ON / OFF times of 15 minutes. Trippers slide in and out of dial for fast
accurate setting. The skipper models provide for operations to be omitted on selected day(s) of the week.
Model with carryover provides a minimum of 16 hours of carryover to maintain preset schedules within
+/- 2% accuracy during power failures. The carryover automatically rewinds when power resumes. Only one
hour is required to rewind the carryover for each two hours of power outage.
Applications
• Oil Well Pumps
• Filters
• Blowers
• Poultry Feeders
• Heaters
• Process Equipment
• Recorded Music
• Dairy Equipment
• Fans
• Silo Unloaders
• Poultry Foggers
Specifications
Case – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in gray finish. Spring hasp,
with hole for lock, holds permanently attached, side hinged door closed. Three mounting holes on back
plus handy box mounting holes.
Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on
bottom.
Optional Enclosures – See Time Switch Cases for optional enclosures.
Special Voltages and Cycles – See Time Switch Motors for available motors.
Switch Rating – 20 Amp maximum 125, 208-277 and 480 VAC; 1/2 HP , 125 VAC; 1 HP, 250 VAC
Power Input – 5 Watts maximum.
Model #
T1905
T1905E
T1906
T1975
T1976
T1975E
MODEL # STEEL
NEMA 3R CASE
T1975R
T1976R
T1975ER
Switch
Clock Motor
Volts 60 Hz
Spring Wound
Carryover
Amps
Skipper
Wheel
SPDT
SPDT
SPDT
SPDT
SPDT
SPDT
125
480
208-277
125
208-277
480
No
No
No
No
No
No
20
20
20
20
20
20
No
Yes
No
Yes
Yes
Yes
C22.2-177
LR3730
UL917
2.75 lbs
1.25 kg
-40°F
(-40°C)
to
130°F
(54°C)
For additional trippers (12 per pack), order No. 156T1950A.
Replacement Snap Switch 133T701A.
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
29
Time Switches
Short Range Cycle Timer
Short Range Cycle Timers provide repeat cycling for “ON” times. Ten combination “ON/OFF” trippers supplied
with each switch.
Applications
• Ventilating Fans
• Fogging Equipment
• Process Equipment
• Spraying Equipment
• Poultry Feeders
• Livestock Feeders
• Pumps
• Poultry Fans
• Bulk Milk Coolers
Specifications
Case – Same as T100 Series.
Knockouts – Same as T100 Series.
Optional Enclosures – Same as T100 Series.
Switch Rating – 20 Amp Resistive 125, 208-277 VAC; 1/2 HP, 125 VAC; 1 HP, 250 VAC
Model #
C22.2-177
LR3730
UL917
30
2.75 lbs
1.25 kg
-40°F
(-40°C)
to
130°F
(54°C)
C8815
C8835
C8865
C8845
C8866
Switch
Clock Motor Volts 60 Hz
Dial Cycle
Tripper Actuating Time
Amps
SPDT
SPDT
SPDT
SPDT
SPDT
125
125
125
125
250
10 Min.
30 Min.
1 Hr.
4 Hr.
1 Hr.
5 Sec.
15 Sec.
30 Sec.
120 Sec.
30 Sec.
20
20
20
20
20
Note: The life of the switch contacts is affected by the size and type of the controlled load. The expected minimum life at 20 amps (resistive)
load is 100,000 cycles.
Replacement Snap Switch 133T773A.
For additional trippers (12 trippers per pack), order No. 156T1950A.
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Time Switches
Sprinkler/Irrigation Timer with 14-Day Skipper
These irrigation timers permit 1 to 60 “ON” operations every 24 hours. This series is designed for water
metering in increments of 12 minutes to 20 hours - 45 minutes for maximum conservation of precious water
resources. The 14-day skipper feature permits irrigation to be omitted on selected day(s) and also provides for
“every other” day operation. The “ON/OFF/AUTOMATIC” switch allows shutdown during rainy days or
extended watering during dry periods without disturbing the automatic cycle set on dial.
Applications
• Multi-Station Hydro Indexing Valves
• Irrigation Control
• Greenhouses
• Feeders
• Lawn Sprinkling
• Drip Irrigation Systems
• Pumps
Specifications
Case – Plastic NEMA 3R case. Cases include hanging bracket plus two mounting holes on back below
switch for mounting.
Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case, and two on
bottom.
Switch Rating –
T8805P101C – 15 Amps, 125 VAC, 1/2 HP, SPST.
R8806P101C – 25 Amps, 208-277 VAC, 2 HP, DPST relay.
R8815P101C – 25 Amps, 120 VAC, 1-1/2 HP, DPST relay.
R8816P101C – 25 Amps, 208-277 VAC, 3 HP, DPST relay.
T8845PV – 125 VAC, SPST, output 24 Volts - 20VA
Model #
T8805P101C
R8806P101C
R8815P101C*
R8816P101C*
T8845PV**
Switch
Motor Voltage 60 Hz
Output Voltage 60 Hz
AMPS (per pole)
HP Rating
SPST
DPST
DPST
DPST
SPST
125
208-277
120
208-277
125
––
—
—
––
24
15
25
25
25
20VA
1/2
2
1-1/2
3
––
C22.2-177
LR3730
UL917
3.75 lbs
1.7 kg
-40°F
(-40°C)
to
130°F
(54°C)
* Includes rain sensor input terminals- rain sensor not supplied.
** Includes 24 volt - 20 VA transformer.
For additional trippers (12 per pack), order No. 156T1950A.
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
31
Time Switches
Timing Control Center, 7-Day Dial with Carryover
This series provides photo control initiated / time switch terminated control. These time switches provide a
different “ON/OFF” program each day of the week and a spring wound carryover. These time switches are
recommended for applications where you need to turn a load “ON” at dusk and “OFF” at a preset time. The
spring wound carryover provides a carryover of 16 hours minimum to maintain accurate load control even
during power failure. When power resumes, the carryover automatically rewinds itself. Only 1 hour is required
to rewind the carryover for each 2 hours of outage. The three models provide control of 1, 2 or 3 circuits. A
light level adjustment is provided on the photo control. All models have single pole double throw switches and
manual circuit by-pass switches.
Unit is designed to control the contactor control circuit only. It is not recommended for direct switching of
tungsten, mercury vapor or similar loads.
Applications
• Parking Lot Lighting
• Storefront Lighting
• Landscape Lighting
• Stairway Lighting
• Billboard Lighting
• Car Lot Lighting
• Entryway Lighting
• Security Lighting
Specifications
Case – Steel in gray finish 12-1/2" (31.7 cm) high, 8-1/4" (21.0 cm) wide, 4" (10.2 cm) deep. Indoor type
with toggle action drawbolt and locking feature. Four mounting holes on back. Separate grounding terminal.
Knockouts – Combination 1/2"-3/4" nominal knockouts, two on back one on each side and two on bottom.
Also one 1" nominal on bottom center.
Optional Enclosures – None available.
Contact Rating – 15 Amp, 1/2 HP, 125/250 VAC; 420 VA pilot duty; 150 Watts Tungsten, 125 VAC (May
also be used with 24 volt systems if wired in accordance with National Electrical Code Regulations.)
Model #
Description
Clock Motor Volts 60 Hz
T51211BC
Circuit A
Circuit B
Circuit A
Circuit B
Circuit C
120
—
120
—
—
T51311BC
C22.2-177
LR3730
UL917
10.5 lbs
4.8 kg
-40°F
(-40°C)
to
130°F
(54°C)
-
Sunset, Photo Control ON - Preset Time Switch OFF
Sunset, Photo Control ON - Sunrise, Photo Control OFF
Sunset, Photo Control ON - Preset Time Switch OFF
Sunset, Photo Control ON - Sunrise, Photo Control OFF
Preset Time Switch ON - Preset Time Switch OFF
All models have separate clock motor terminals for switching circuits not on line voltage.
For additional trippers (7 ON / 7 Off per pack), order No. 156T2548A.
See Next Generation Electronic Time Switches with Astro Feature
32
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Time Switches
Compact, 7-Day
The T2000 Series provides up to 84 (42 “ON/OFF”) operations each week. Minimum “ON/OFF” times for this
series are 2 hours each providing up to 6 “ON/OFF” operations each day.
Applications
• Heating
• Lights
• Air Conditioning
• Pumps
• Ventilating
• Motors
• Defrost Control
• Fans
Specifications
Case – Drawn steel 7-3/4" (19.7 cm) high, 5" (12.7 cm) wide, 3" (7.6 cm) deep in gray finish. Spring hasp,
with hole for lock, holds permanently attached, side hinged door closed. Three mounting holes on back
plus handy box mounting holes.
Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on
bottom.
Optional Enclosures – See Time Switch Cases for optional enclosures.
Special Voltages and Cycles – See Time Switch Motors for available motors.
Switch Rating – 20 Amp Resistive, 125 and 208-277 VAC; 1/2 HP 125 VAC; 1 HP 250 VAC
Model #
Switch
Clock Motor Volts 60 Hz
Amps
T2005
T2006
SPDT
SPDT
125
208-277
20
20
For additional trippers (12 per pack), order No. 156T1950A.
Replacement Snap Switch 133T701A.
C22.2-177
LR3730
UL917
2.75 lbs
1.25 kg
-40°F
(-40°C)
to
130°F
(54°C)
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
33
Time Switches
7-Day Dial With & Without Carryover
These time switches provide a different “ON/OFF” program each day of the week. They also provide for 4 pole
single throw and 4 pole (2NO/2NC) switching. This series provides true 7-day load control with minimum ON
and minimum OFF times of 3-1/2 hours. The “BC” models with carryover provide a carryover of 16 hours
minimum to maintain accurate load control even during power failure. When power resumes, the carryover
automatically rewinds itself. Only 1 hour is required to rewind the carryover for each 2 hours of outage.
Applications
• Heating
• Outdoor Lighting
• Ventilating Systems
• Air Conditioning
• Motors
• Fans
• Pumps
• Signs
• Filters
• Indoor Lighting
• Billboards
• 3 Phase Loads
Specifications
C22.2-177 Models
LR3730
without
UL917
carryover
8 lbs
3.6 kg
Models
with
carryover
9 lbs
4.1 kg
-40°F
(-40°C)
to
130°F
(54°C)
Case – Steel in gray finish 12-1/2" (31.7 cm) high, 8-1/4" (21.0 cm) wide, 4" (10.2 cm) deep. Indoor type
with toggle action drawbolt and locking feature. Four mounting holes on back. Separate grounding terminal.
Knockouts – Combination 1/2"-3/4" nominal knockouts, two on back, one on each side and two on bottom.
Also one 1" nominal on bottom center.
Optional Enclosures – See Time Switch Cases for optional enclosures.
Special Voltages and Cycles – See Time Switch Motors for available motors. Contact factory for availability of time switch with 50 cycle or other voltages.
Switch Rating – Each Pole 40 amp resistive, 120-480 VAC; 40 amp tungsten, inductive or 1000 VA pilot
duty, 120-277 VAC; 2 HP (24 FLA) 120 VAC; 5 HP (28 FLA) 240 VAC single phase; 7-1/2 HP (28 FLA) 208
VAC three phase; 10 HP (28 FLA) 240 VAC three phase.
Carryover – Minimum time - mechanical operation: 16 hours. Carryover accuracy +/-2%.
Model l#
T7401B
T7402B
T7801B
T7802B
Model #
Steel NEMA 3R Case
Model with
CarryOver
T7401BR
T7401BC
T7402BC
T7801BC
T7802BC
Switch
Clock Motor
Volts 60 Hz
Amps
(per pole)
4PST
4PST
2NO/2NC
2NO/2NC
125
208-277
125
208-277
40
40
40
40
* All models (B or BC suffix) have separate clock motor terminals for switching circuits not on line voltage.
For additional trippers (7 ON / 7 OFF per pack), order No. 156T2548A.
34
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Time Switches
Astro Dial With Skipper & Carryover
This time switch self adjusts for seasonal changes. The astronomic dial automatically adjusts itself as the days
grow shorter or longer. A skipper provides lighting control to be omitted on selected day(s) of the week. The
carryover is designed to maintain preset schedule during power outages for a minimum of 16 hours. Only
1 hour is required to rewind the carryover for each 2 hours of outage. The 3PST switch configuration provides
for control of 3-phase lighting. Three skipper screws are furnished.
Lighting Applications
• Parking Lots
• Entryways
• Landscape Lights
• Security
• Stairways
• Storefronts
• Billboards
• Car Lots
Specifications
Case – NEMA 3R drawn steel 11-1/2" (29.2 cm) high, 8-1/4" (20.9 cm) wide, 4-1/2" (11.4 cm) deep in gray
finish. Hasp, with hole for lock, holds permanently attached, side hinged door closed. Mounting bracket
plus two holes below switch on back for mounting. Separate grounding terminal.
Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on
bottom.
Optional Enclosures – None.
Switch Rating – Each pole: 40 amp tungsten up to 277 VAC; 1 HP, 120 VAC; 690 VA pilot duty.
Model #
Switch
V45471CR*
V45472CR*
V45471R
V45472R
3PST
3PST
3PST
3PST
Clock Motor Volts 60 Hz
Amps
125
208-277
125
208-277
40
40
40
40
# Indicate City and State nearest installation when ordering.
* Includes spring wound carryover.
For additional skipper screws (3 skipper screws per pack), order No. 156T1957A.
UL917
E10694
C22.2-177 Models
LR3730
V45471C
R&
V45472C
R
9 lbs
4.1 kg
Other
Models
5 lbs
2.3 kg
-40°F
(-40°C)
to
130°F
(54°C)
For Electronic Time Switches which offer Astro Feature please see pages 42-44
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
35
Time Switches
Water Heater Time Switches
The WH40 provides a convenient external override switch. Utilities in many areas of the country offer two
electric rates for residential or commercial customers. One rate has the regular daytime electrical rate, the other
is “off peak” rate. The off peak rate provides customers with “lower-priced” electricity during the nighttime and
weekend periods. These time switches allow the customer to shift electricity use into these off-peak time
periods in an attempt to save utility costs.
Applications
Water Heater Control for:
• Residential
• Commercial
• Industrial
• Institutional / Schools
• Military Facilities
Specifications
The
"LITTLE
GRAY BOX"®
Case – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in gray finish. Spring hasp,
with hole for lock, holds permanently attached, side hinged door closed. Three mounting holes on back
plus handy box mounting holes.
Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on
bottom.
Special Voltages and Cycles – See Time Switch Motors for available motors.
Switch Rating – 40 Amp Resistive, Inductive or Tungsten 120-277 VAC; 1000 VA pilot duty 120-277 VAC; 2
HP (24 FLA) 125 VAC; 5 HP (28 FLA) 240 VAC.
Model #
Switch
Clock Supply Volts 60 Hz
Watts
External Switch
Amps/Pole
T104-20
WH40
DPST
DPST
208-240
250
10000
10000
No
Yes
40
40
For additional trippers (1 ON / 1 OFF per pack), order No. 156T1978A.
C22.2-177
LR3730
UL917
36
2.75 lbs
1.25 kg
-40°F
(-40°C)
to
130°F
(54°C)
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Time Switches
Electronic Water Heater Timers
These time switches provide automatic control for electric water heaters. They provide to-the-minute accuracy
in programming and time keeping. The time switches can be programmed for repeat daily scheduling, 5-day
working week scheduling, weekend scheduling or any individual day scheduling. Timers can be scheduled for
operation during the lowest time-of-day rates or to switch off the electric heater during period of utilities peak
power usage. The time switch can be set to operate for up to 6 on/off operations daily for a maximum of
42 on/off operations weekly. Both models provide a convenient external override switch and LED load indicator
for ease in scheduling hot water as required for extra hot water demands. The timers include a “AA” alkaline
battery carryover which protects both time keeping and program information for a minimum of 3 years.
Applications
Water Heater Control for:
• Residential
• Military Facilities
• Institutional
• Schools
• Industrial
• Commercial
Specifications
Case – Drawn steel 7-3/4" (19.7 cm) H x 5" (12.7 cm) W x 3" (7.6 cm) D in gray finish. Spring hasp, with
hole for lock, holds permanently attached, side hinged door closed. Three mounting holes on back plus
handy box mounting holes.
Knockouts – Combination 1/2"–3/4" nominal knockouts, one on back and each side of case and two on
bottom.
Switch Rating – 30 Amp Resistive or Inductive 120-240 VAC; 1 HP, 120 VAC; 1-1/2 HP, 240 VAC;
5 Amps Tungsten, 120/240 VAC.
Model #
Switch
Clock Supply Volts 50/60 Hz
Watts
External Switch
Amps/Pole
EH10
EH40
SPST
DPST
120
240
3600
7200
Yes
Yes
30
30
With Manual External
Override and Load Indicator
50/60 Hz Operation
UL916
E76987
C22.2-177
LR3730
2.75 lbs
1.25 kg
-4°F
(-20°C)
to
122°F
(50°C)
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
37
Time Switch Cases
A. Plastic Case
Ends rusting problems forever.
Made of heavy-duty industrial grade plastic, Intermatic’s rainproof all plastic case is perfect for applications
where high humidity and/or dust can be a problem. Developed for use with pool and spa equipment, the
non-corroding plastic case is useful for applications in other high moisture areas such as car washes,
industrial water spray areas, etc; NEMA 3R case.
A. 2T2500GA
Plastic Case NEMA 3R
A hasp with a hole for lock holds the side-hinged door closed. A bracket plus two holes below the switch on
the back are for mounting. Has five combination 1/2 - 3/4" nominal knockouts, one on back and each side of
case, two on bottom.
Model Number
Description
Weight
2T2500GA*
2T2502GA*
Indoor / Outdoor Plastic Case – 9-3/8" x 5-1/2" x 3-3/4"
Beige Indoor / Outdoor Plastic Case – 9-3/8" x 5-1/2" x 3-3/4"
1.3 lbs
1.3 lbs
*
Available for SERIES T100, T170, T180, T1100, T1200, T1400, T1900, T2000, C8800, ET100C, ET170C,ET700C and models EH10,
EH40, ET279C ET70115, ET70215, and ET8000 series
B. Standard Case
B. 2T2040GA
Standard Case NEMA 1
Drawn steel with gray powder coat paint finish. Spring hasp (with hole for seal or lock) holds permanently
attached hinged door closed. Has combination 1/2" - 3/4" nominal knockouts, one on back and on each side,
and two on bottom. (Except “P” Series switches which are equipped with cord-connection and receptacle.)
Convenient mounting holes. NEMA Type 1.
Model Number
Description
Weight
2T2040GA*
2T2292GA**
Standard Indoor Case – 7 3/4" x 5" x 3"
Indoor Case – 12-1/2" x 8-1/4" x 3-7/8"
1.4 lbs
7.0 lbs
*
Available for SERIES T100, T170, T180, T1100, T1200, T1400, T1900, T2000, C8800, ET100C, ET170C,ET700C and models EH10,
EH40, ET279C ET70115, ET70215, and ET8000 series
** Available for SERIES T7400B, T7800B, T7400BC and T7800BC.
C. Indoor-Outdoor Case
C. 2T511GA
Steel Indoor/Outdoor Case NEMA 3R
For protecting time switch from rain, sleet, snow and ice. Drawn steel with gray or beige powder coat paint
.036" construction with side-hinged door. Hasp provided for lock. Has combination 1/2-3/4" nominal
knockouts, one on back and each side of case, and two on bottom. Separate grounding terminal. Convenient
mounting holes. NEMA 3R.
Model Number
Description
Weight
2T511GA*
2T2485GA*
2T2331GA**
2T2293GA***
2T1985GR****
Standard Indoor/Outdoor Case – 9-3/8" x 5-1/2" x 3-5/8"
Beige Standard Indoor/Outdoor Case – 9-3/8" x 5-1/2" x 3-5/8"
Indoor/Outdoor Case – 9-3/8" x 5-1/2" x 3-5/8"
Indoor/Outdoor Case – 12-1/2" x 8-1/4" x 3-7/8"
Indoor/Outdoor Case – 9-3/8" x 5-1/2" x 3-5/8"
2.5 lbs
2.5 lbs
2.5 lbs
2.5 lbs
2.5 lbs
*
Available for SERIES T100, T170, T180, T1100, T1200, T1400, T1900, T2000, C8800, ET100C, ET170C,ET700C and models EH10,
EH40, ET279C ET70115, ET70215, and ET8000 series
**
Available for SERIES T100CR, T170CR, T1400BR, T1400BCR, T1800BR and T1800BCR.
***
Available for SERIES T7400B, T7800B, T7400BC and T7800BC.
**** Available for SERIES LS7000 only.
D. TS100RS
Steel Indoor/Outdoor Case NEMA 3R
D. Stainless Steel Indoor-Outdoor Case
Model Number
Description
Weight
TS100RS
Stainless Steel Indoor-Outdoor Case – 9 7/8" x 6 1/2" x 3 1/5"
3.5 lbs
*
UL & CSA apply to all
enclosures shown.
38
UL917
E10694
Available for SERIES T100, T170, T1400, T1900, T2000, C8800, ET100C, ET170C, ET700C, EH40, ET279C, ET70115,
ET70215 and ET8000.
C22.2-177
LR3730
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Time Switch Cases
E. 2-in-1 Raintight Case and Panel
22T713
(Brackets Only)
For use where 2 time switches are to be mounted side by side. Heavy-duty spot-welded raintight construction
with powder coat paint. Hasp (with hole for lock) holds permanently attached hinged door closed. Combination
1/2" - 3/4" nominal knockouts conveniently located (two on back, five on bottom and one on each side).
Top mounting brackets plus two holes below switch level on back of case.
Model Number
Description
Weight
T10000R (replaces 2T2089GA)*
T30000R*
T40000R*
2-in-1 Indoor/Outdoor Case – 10-1/2" x 10-1/2" x 4"
Indoor/Outdoor Panel – 16-3/4" x 10-1/2" x 4-1/4"
Indoor/Outdoor Panel – 20-3/4" x 12-3/4" x 4-1/4"
6.5 lbs
11.0 lbs
17.0 lbs
*
Available for SERIES T100, T170, T180, T1900, T2000 and C8800. NOT FOR T1400/T1800/T1900 MODELS WITH BCR SUFFIX.
F. Flushmount Case
E. T10000R
For concealing mechanism in wall and giving a finished, flushed appearance. Heavy-duty, .063" formed steel
construction with hinged door. Gray finish with powder coat paint. Combination 1/2" - 3/4" nominal knockouts
one each side, and two on bottom, plus one 1" knockout on top and bottom. Convenient mounting holes.
With or without key lock. Cutout 9-1/8" x 6" x 4-1/8" deep; flange 11" x 8"
Model Number
Description
Weight
2T308A*
2T2365GA**
6ET1398GA
2T2366GA
Standard Flushmount w/Lock
Flushmount Case w/Lock
Flush Cover for ET70415CR and ET70415CR24
Flush Cover for ET70415CR and ET70415CR24 with lock
6.5 lbs
7.0 lbs
2.5 lbs
2.5 lbs
2-in-1 Raintight Case
* Available for SERIES T100, T170, T180, T1900, T2000 and C8800. NOT FOR T1400/T1800/T1900 MODELS WITH BCR SUFFIX.
** Available for SERIES ET100C, ET170C, ET700C and models EH10, EH40, ET279C, ET7115C, ET7215C, ET70215C and ET70115C.
G. Mounting Brackets
Heavy gauge steel mounting bracket mounts to a standard symmetrical rail TS35 according to DIN46277 and
EN50022. Ideal for panel mounting of mechanical or electronic time switch controls, along side of other DIN
rail mountable electrical devices. This snap-in type bracket accepts a wide range of Intermatic time switches
including most T100, T170, T180, T1900, T2000, C8800, ET100, ET170, ET700 and ET70000 time switches.
Model Number
Description
Weight
22T535GR
22T338GR
Din Rail Bracket – 6" x 5" x 2"
Surface Mount Snap-in Bracket – 6" x 5" x 2"
1.0 lbs
1.0 lbs
F. 2T2365GA
Flushmount Case
Surface
Mount
Bracket
G. 22T338GR
UL917
E10694
C22.2-177
LR3730
Din Rail
Bracket
22T535GR
UL & CSA apply to all
enclosures shown.
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
39
Electronic Energy Controls
24-Hour Electronic Time Switches
ET100 Series 24-Hour Time Switch (Same Operation Each Day)
These time switches provide the same dependable and uncomplicated performance as the T101 mechanical
time switch...plus to-the-minute programming for accurate load control and reduced energy costs. Up to 8 set
points or events (4 ON/4 OFF) can be preset to automatically repeat on a daily basis. The program can be
overridden at any time by placing the selector switch in the Manual position. Two industrial grade “AA”
Alkaline batteries provide 3 years minimum program and timing protection.
Specifications
Case – NEMA 1 – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in gray finish.
Note: The electronic mechanism snaps into the standard Intermatic time switch case, replacing mechanical mechanisms, if desired.
Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on
bottom.
Optional Enclosures – See Time Switch Cases for optional enclosures.
Special Voltages and Cycles – ALL models 50 or 60 Hz.
Switch Rating – Except model ET100C. 30 Amp Inductive/Resistive, 24 / 120 / 240 / 277 VAC 60 Hz; 20
Amp Resistive, 28 VDC; 1 HP 120 VAC 60 Hz; 2 HP 240 VAC 60 Hz; 5 Amp Tungsten, 120 / 240 / VAC 60
Hz; 20 Amp ballast,120-277 VAC 60 Hz. ET100C same ratings for 120 Volt loads only. Models ET105C
normally closed contact ratings: 10A Resistive/General purpose, 12 - 277VAC; 10A Resistive/General
purpose, 28VDC; 3A Ballast, 120 - 277VAC; 1/4 HP, 120 VAC; 1/2 HP, 240 VAC; 30 LRA; 12 FLA; 275 VA
pilot duty, 120 - 240 VAC
Carry-over – Field replaceable “AA” batteries maintain program and accurate time keeping for 3 years
minimum. Up front replacement does not require removal of mechanism or field wiring.
Wiring Terminals – #18 to #10 AWG wire.
Minimum ON/OFF Times – 1 minute.
Maximum ON/OFF Times – 23 hours 59 minutes.
Applications:
• Schools
• Offices
• Airports
• Stores
• Hotels
• Restaurants
• Parks
• Apartments
For Controlling:
• Water Heaters
• Parking Lot Lighting
• Commercial Ovens
• Interior Lighting
• Air Conditioners
• Fans/Blowers/Pumps
• Livestock Feeders
• Poultry Equipment
• Process Equipment
Engineering Specification
24 Hour Electronic Time Switch
The time switch shall be a solid state electronic control capable of permitting 8 ON/OFF set points to be distributed on a daily schedule. The
time and set points shall be programmable to the nearest minute with a minimum ON duration of 1 minute and a maximum ON duration of 23
hours and 59 minutes. The timer shall have a digital LCD readout to show time-of-day using 12 hour AM/PM indicator. The time switch shall
provide a manual override control for both temporary or permanent override. Time switch shall operate over a temperature range of -40°F (40°C) to 155°F (68°C).
An industrial grade AA alkaline battery shall protect program information and time-of-day for a minimum of 3 years. Switch configuration to be
__________ (SPST) or (DPST) with a UL listed rating of: 30 amp Inductive/Resistive, 24/120/240 Volts AC, 60 Hz; 20 amps Resistive, 28 VDC;
1 HP, 120 Volts AC, 60 Hz; 2 HP, 240 Volts AC, 60 Hz; 5 amps Tungsten, 120/240 Volts AC, 60 Hz; 20 amps Ballast, 120-277 Volts AC, 60 Hz.
The time switch shall be powered by a __________ (120 volt), (120-277 volts) 50/60 Hz source. The time switch shall be enclosed in a
lockable steel NEMA 1 rated enclosure. The time switch shall be UL listed under UL category 916 Energy Management Equipment and shall be
INTERMATIC Model __________.
UL917
C22.2-177
LR3730
2.5 lbs
1.1 kg
-40°F
(-40°C)
to
155°F
(68°C)
Model#
ET100C
ET100CM1
ET101C
ET102C
ET103C
ET104C
ET104CP2
ET105C
1
2
40
Circuits
Switch
Clock Voltage
Amp Rating
HP Rating
Enclosure
1
1
1
1
1
1
1
1
SPST
SPST
SPST
SPST
DPST
DPST
DPST
SPDT
120
120
120
120/208/240/277
120
120/208/240/277
120/208/240/277
120
30
30
30
30
30
30
30
10/30
1HP
1HP
1HP / 2HP
1HP / 2HP
1HP / 2HP
1HP / 2HP
1HP / 2HP
1HP / 2HP
NEMA1
Mech.
NEMA1
NEMA1
NEMA1
NEMA1
NEMA3R
NEMA1
Mechanism only no case.
NEMA 3R UV resistant polycarbonate plastic case.
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Electronic Energy Controls
7-Day Electronic Time Switches
ET170 Series 7-Day Time Switch (Permits Different Operation Each Day)
These electronic time switches provide to-the-minute programming for accurate load control and reduced
energy costs. Up to 20 set points or events (10 ON/10 OFF or any combination) can be preset to automatically
repeat on a weekly or daily basis. The program can be overridden at any time by placing the selector switch in
the Manual position. These time switches provide for true 7-day load control with up to 140 operations
(70 ON/70 OFF or any combination) each week. Model ET279C provides 20 operations or momentary contact
closures of 1 to 8 seconds (ten each or any combination) for two independent circuits.
Specifications
Case – NEMA 1 – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in gray finish.
NEMA 3R – Drawn steel 9-3/8" (23.8 cm) high, 5-1/2" (14.0 cm) wide, 3-5/8" (9.0 cm) deep in gray finish.
Both types include permanently attached side hinged door with lockable hasp. Mounting holes and/or
mounting bracket included. Separate grounding terminal.
Note: The electronic mechanism snaps into the standard Intermatic time switch case, replacing mechanical mechanisms, if desired.
Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on
bottom.
Optional Enclosures – See Time Switch Cases for optional enclosures.
Special Voltages and Cycles – ALL models 50 or 60 Hz.
Switch Rating – 30 Amp Inductive/Resistive, 24 / 120 / 240 / 277 VAC 60 Hz; 20 Amp Resistive, 28 VDC;
1 HP 120 VAC 60 Hz; 2 HP 240 VAC 60 Hz; 5 Amp Tungsten, 120 / 240 / VAC 60 Hz; 20 Amp ballast,
120-277 VAC 60 Hz. ET100C same ratings for 120 Volt loads only. Model ET175C normally closed contact
ratings: 10A Resistive/General purpose, 12 - 277VAC; 10A Resistive/General purpose, 28VDC; 3A Ballast,
120 - 277VAC; 1/4 HP, 120 VAC; 1/2 HP, 240 VAC; 30 LRA; 12 FLA; 275 VA pilot duty, 120 - 240 VAC
Carry-over – Field replaceable “AA” batteries maintain program and accurate time keeping for 3 years
minimum. Up front replacement does not require removal of mechanism or field wiring.
Wiring Terminals – #18 to #10 AWG wire.
Minimum ON/OFF Times – 1 minute.
Maximum ON/OFF Times – 6 days 23 hours 59 minutes.
Engineering Specification
7 Day 30 Amp Electronic Time Switches
The time switch shall be a solid state electronic control capable of permitting 20 ON/OFF set points to be distributed on independent daily
schedules through a 7-day time period. The time switch shall include a 7-day repeat feature for simplifying programming of identical set points.
The time and set points shall be programmable to the nearest minute with a minimum ON duration of 1 minute and a maximum ON duration of
6 days, 23 hours, 59 minutes. The timer shall have a digital LCD readout to show day of week and time-of-day using 12 hour AM/PM indicator.
The time switch shall provide a manual override control for both temporary or permanent override. Time switch shall operate over a temperature range of -40°F (-40°C) to 155°F (68°C). An industrial grade AA alkaline battery shall protect program information and time-of-day for a
minimum of 3 years. Switch configuration to be __________ (SPST) or (DPST) with a UL listed rating of: 30 amp Inductive/Resistive,
24/120/240 Volts AC, 60 Hz; 20 amps Resistive, 28 VDC; 1 HP, 120 Volts AC, 60 Hz; 2 HP, 240 Volts AC, 60 Hz; 5 amps Tungsten, 120/240
ENERGY CODE UPDATE
In 2002 the Department of Energy (DOE) settled
on ASHRAE 90.1-1999 as the commercial
building standard for state building energy
codes acting on its authority under the Energy
Conservation & Production Act. The deadline
set by the DOE for state compliance was July
15, 2004 by which each state must enact
energy codes at least as strict as the standard
or provide justification for non-compliance.
Intermatic offers a variety of products to assist
the specifying engineer and contractor with
meeting the ASHRAE 90.1-1999 requirements
including the Next Generation series of
programmable time switches, spring wound
and electronic in-wall timers, and a full line of
photo controls.
Volts AC, 60 Hz; 20 amps Ballast, 120-277 Volts AC, 60 Hz.
The time switch shall be powered by a __________ (120 volt), (120-277 volts) 50/60 Hz source. The time switch shall be enclosed in a
lockable steel NEMA 1 rated enclosure. The time switch shall be UL listed under UL category 916 Energy Management Equipment and shall be
INTERMATIC Model __________.
Model#
Circuits
Switch
Clock Voltage
Amp Rating
HP Rating
Enclosure
ET171C
ET171CR1
ET173C
ET174C
ET175C
ET279C2,3
1
1
1
1
1
2
SPST
SPST
DPST
DPST
SPDT
SPST
120
120
120
240
120
120
30
30
30
30
10/30
30
1HP / 2HP
1HP / 2HP
1HP / 2HP
1HP / 2HP
1HP / 2HP
1HP / 2HP
NEMA1
NEMA3R
NEMA1
NEMA1
NEMA1
NEMA1
1
2
3
UL917
C22.2-177
LR3730
2.5 lbs
1.1 kg
-40°F
(-40°C)
to
155°F
(68°C)
NEMA 3R drawn steel enclosure.
User selectable contacts independent 2xSPST, simultaneous DPST, or pulsed for mechanically held contactor operation.
Complies with California Title 24 requirements for multi-level outdoor lighting control.
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
41
Electronic Energy Controls
7-Day Electronic Astronomic Time Switches
ET8000 Series 7-Day Astronomic Time Switch (Tracks Sunrise & Sunset)
Intermatic’s Electronic Astronomic 7-Day Time Switch automatically switches loads according to a preset
weekly schedule with to-the-minute accuracy. The astronomic feature provides sunset ON and sunrise OFF
settings to eliminate the need for separate photo control devices. The independent 7-day programming
provides complete flexibility for applications where load switching differs each day of the week. Astronomic
programming can be combined with independent programs to provide a sunset ON and timed OFF program.
Specifications
Case – NEMA 1 – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in gray finish.
NEMA 3R – Drawn steel 9-3/8" (23.8 cm) high, 5-1/2" (14.0 cm) wide, 3-5/8" (9.0 cm) deep in gray finish.
Both types include permanently attached side hinged door with lockable hasp. Mounting holes and/or
mounting bracket included. Separate grounding terminal.
Note: The electronic mechanism snaps into the standard Intermatic time switch case, replacing mechanical mechanisms, if desired.
Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on
bottom.
Optional Enclosures – See Time Switch Cases for optional enclosures.
Special Voltages and Cycles – ALL models 50 or 60 Hz.
Switch Rating – 30 Amp Inductive/Resistive, 24 / 120 / 240 / 277 VAC 60 Hz; 20 Amp Resistive, 28 VDC;
1 HP 120 VAC 60 Hz; 2 HP 240 VAC 60 Hz; 5 Amp Tungsten, 120 / 240 / VAC 60 Hz; 20 Amp ballast,
120-277 VAC 60 Hz. Model ET8115C normally closed contact ratings: 10A Resistive/General purpose,
12 - 277VAC; 10A Resistive/General purpose, 28VDC; 3A Ballast, 120 - 277VAC; 1/4 HP, 120 VAC; 1/2 HP,
240 VAC; 30 LRA; 12 FLA; 275 VA pilot duty, 120 - 240 VAC
Carry-over – Field replaceable “AAA” batteries maintain program and accurate time keeping for 3 years
minimum. Up front replacement does not require removal of mechanism or field wiring.
Wiring Terminals – #18 to #10 AWG wire.
Minimum ON/OFF Times – 1 minute.
Maximum ON/OFF Times – 6 days 23 hours 59 minutes.
Applications:
• Schools
• Offices
• Airports
• Stores
• Hotels
• Restaurants
• Parks
• Apartments
For Controlling:
• Water Heaters
• Parking Lot Lighting
• Commercial Ovens
• Interior Lighting
• Air Conditioners
• Fans/Blowers/Pumps
• Livestock Feeders
• Poultry Equipment
• Process Equipment
Engineering Specification
7 Day 30 Amp Electronic Time Switches
The time switch shall be a solid state electronic control capable of permitting 14 ON, 14 OFF set points to be distributed on independent daily
schedules through a 7-day time period with 1 astro ON and 1 astro OFF set point per controlled channel . The time switch shall include a 7-day
repeat feature for simplifying programming of identical set points. The time and set points shall be programmable to the nearest minute with a
minimum ON duration of 1 minute and a maximum ON duration of 6 days, 23 hours, 59 minutes. The timer shall have a digital LCD readout to
show day of week, time-of-day, and date using 12 hour AM/PM indicator. The time switch shall provide a manual override control for both
temporary or permanent override. Time switch shall operate over a temperature range of -40°F (-40°C) to 155°F (68°C).
UL917
C22.2-177
LR3730
2.5 lbs
1.1 kg
-40°F
(-40°C)
to
155°F
(68°C)
An industrial grade AAA alkaline battery shall protect program information and time-of-day for a minimum of 3 years. Switch configuration to
be __________ (SPST) or (DPST) with a UL listed rating of: 30 amp Inductive/Resistive, 24/120/240 Volts AC, 60 Hz; 20 amps Resistive, 28
VDC; 1 HP, 120 Volts AC, 60 Hz;
2 HP, 240 Volts AC, 60 Hz; 5 amps Tungsten, 120/240 Volts AC, 60 Hz; 20 amps Ballast, 120-277 Volts AC, 60 Hz
The time switch shall be powered by a __________ (120 volt), (120-277 volts) 50/60 Hz source. The time switch shall be enclosed in a
lockable steel NEMA 1 rated enclosure. The time switch shall be UL listed under UL category 916 Energy Management Equipment and shall be
INTERMATIC Model __________.
Model#
CPD82
NEMA 3R with clear cover
ET8015C
ET8015CPD82
ET8015CR1
ET8115C
ET8115CPD82
ET8115CR1
ET8215C2,3
ET8215CPD822,3
ET8215CR1,2,3
1
2
3
42
Circuits
Switch
Clock Voltage
Amp Rating
HP Rating
Enclosure
1
1
1
1
1
1
2
2
2
SPST
SPST
SPST
SPDT
SPDT
SPDT
SPST
SPST
SPST
120/208/240/277
120/208/240/277
120/208/240/277
120/208/240/277
120/208/240/277
120/208/240/277
120/208/240/277
120/208/240/277
120/208/240/277
30
30
30
10/30
10/30
10/30
30
30
30
1HP / 2HP
1HP / 2HP
1HP / 2HP
1HP / 2HP
1HP / 2HP
1HP / 2HP
1HP / 2HP
1HP / 2HP
1HP / 2HP
NEMA1
NEMA3R
NEMA3R
NEMA1
NEMA3R
NEMA3R
NEMA1
NEMA3R
NEMA3R
NEMA 3R drawn steel enclosure.
User selectable contacts independent 2xSPST, simultaneous DPST, or pulsed for mechanically held contactor operation.
Complies with California Title 24 requirements for multi-level outdoor lighting control.
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Electronic Energy Controls
365-Day Electronic Astronomic Time Switches
ET70000 Series 365-Day Time Switch (1 & 2 Circuit Models)
These electronic time switches provide to-the-minute programming for 7-day or full year load control.
Features: 12/24 Hr clock format, 1,000 + ON/OFF events, 99 holiday schedules, and auto daylight savings time
adjustment. Flexible load control is enhanced by Astro, Variable Pulse, and Interval options as required for
outdoor lighting control, bell ringing and after hours temporary override respectively. Non-volatile memory
maintains all programmed switching times for the life of the time switch. A factory installed field replaceable
lithium battery maintains accurate time keeping and calender information for a minimum of 8 years.
Specifications
Case – NEMA 1 – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in gray finish.
NEMA 3R – Drawn steel 9-3/8" (23.8 cm) high, 5-1/2" (14.0 cm) wide, 3-5/8" (9.0 cm) deep in gray finish.
Both types include permanently attached side hinged door with lockable hasp. Mounting holes and/or
mounting bracket included. Separate grounding terminal.
Note: The electronic mechanism snaps into the standard Intermatic time switch case, replacing mechanical mechanisms, if desired.
ON/OFF Events – 1,000+ Events.
Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on
bottom.
Optional Enclosures –See Time Switch Cases for optional enclosures.
Special Voltages and Cycles – Line voltage models 50 or 60 Hz; Low voltage models 60 Hz 24 Volts.
Switch Rating – Each Pole; 20 amp resistive/general purpose, 12–277 Volts AC; 20 amp resistive/general
purpose, 28 Volts DC; 20 amp ballast, 120–277 VAC; 1 HP, 120 VAC 60 Hz; 98 LRA; 22 FLA; 2 HP, 240 VAC
60 Hz; 80 LRA; 30 FLA; 5 amp tungsten, 120–240 VAC; 470 VA pilot duty, 12–240 VAC; TV-5, 120–240
VAC
Carry-over – Non-volatile memory requires no backup. Time keeping and calender data maintained within
0.01% accuracy for minimum of 8 years with one factory installed, field replaceable lithium coin cell.
Wiring Terminals – #18 to #10 AWG wire.
Minimum ON/OFF Times – 1 minute.
Maximum ON/OFF Times – 6 days 23 hours 59 minutes.
Engineering Specification
365 Day 1, 2, & 4 Circuit Electronic Astronomic Time Switches
ASHRAE 90.1-1999 Section
9.2.1.3 Exterior Lighting
Control
Lighting for all exterior applications not
exempted in 9.1 and 9.3.2 shall be controlled
by a photosensor or astronomical time switch
that is capable of automatically turning off the
exterior lighting when sufficient daylight is
available or the lighting is not required.
The time switch shall be a solid state electronic control capable of permitting 1000 ON/OFF set points to be distributed on independent daily
schedules through a 7-day time period and across 99 separate holiday schedules. The time switch shall include a 7-day repeat feature for
simplifying programming of identical set points. The time and set points shall be programmable to the nearest minute with a minimum ON
duration of 1 minute and a maximum ON duration of 6 days, 23 hours, 59 minutes. The timer shall have a digital LED readout to show
day-of-week and time-of-day using 12/24 hour time format. The time switch shall provide a manual override control for both temporary or
permanent override. Time switch shall operate over a temperature range of -40°F (-40°C) to 155°F (68°C). A non-volatile memory shall
maintain all program data for the life of the time switch without the need for battery backup. The time switch shall include a factory installed
lithium battery backup which shall maintain clock time and calendar data for 8 years minimum. Switch configuration to be SPDT for each
circuit with a UL 916 Energy Management Equipment listed rating of: Normally Open Contacts Each Pole; 20 amp resistive/general purpose,
12-277 Volts AC; 20 amp resistive/general purpose, 28 Volts DC; 20 amp ballast, 120-277 VAC; 1 HP, 120 VAC 60 Hz; 98 LRA; 22 FLA; 2 HP,
240 VAC 60 Hz; 80 LRA; 30 FLA; 5 amp tungsten, 120-240 VAC; 470 VA pilot duty, 12-240 VAC; TV-5, 120-240 VAC Normally Closed Contacts
10 Amp Resistive/general purpose, 12-277 VAC; 10 Amp Resistive/general purpose, 28 Volts DC; 3 Amp ballast, 120-277 VAC; 1/4 HP, 120 VAC
60 Hz; 1/2 HP, 240 VAC 60 Hz; 30 LRA; 12 FLA; 275 VA pilot duty, 12-240 VAC. The time switch shall be enclosed in a lockable steel _____
The Intermatic Next Generation series provides
an easy to program time-of-day lighting
control. The multiple zones, as required in the
standard, are available in 1, 2, 4, 8, or 16 zones
of control. Space control for each zone can be
provided by a remote timed override. Each
override can be set for the code required
maximum of four hours.
(NEMA 1) (NEMA 3R) enclosure. The time switch shall be powered by a __________ (user selectable 120, 208, 240 or 277 VAC 50 or 60 Hz)
(24 VAC 60 Hz) source. The time switch shall be INTERMATIC Model ________________ (ET70115C, ET70115CR or ET70115CR24 1-circuit)
(ET70215C, ET70215CR or ET70215CR24 2-circuits)
Model#
ET70115C
ET70115CR1
ET70115CR241
ET70215C2,3
ET70215CR1,2,3
ET70215CR241,2,3
Circuits
Switch
Clock Voltage
Amp Rating
HP Rating
Enclosure
1
1
1
2
2
2
SPDT
SPDT
SPDT
SPDT
SPDT
SPDT
120/208/240/277
120/208/240/277
24
120/208/240/277
120/208/240/277
24
20
20
20
20
20
20
1HP / 2HP
1HP / 2HP
1HP / 2HP
1HP / 2HP
1HP / 2HP
1HP / 2HP
NEMA1
NEMA3R
NEMA3R
NEMA1
NEMA3R
NEMA3R
UL916
E76987
UL917
C22.2-177
LR3730
2.5 lbs
1.1 kg
-40°F
(-40°C)
to
155°F
(68°C)
1
NEMA 3R drawn steel enclosure.
User selectable contacts independent 2xSPST, simultaneous DPST, or pulsed for mechanically held contactor operation.
3Complies with California Title 24 for multi-level outdoor lighting control.
2
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
43
Electronic Energy Controls
365-Day Electronic Astronomic Time Switches
ET70000 Series 365-Day Time Switch (4, 8, & 16 Circuit Models)
These electronic time switches provide to-the-minute programming for 7-day or full year load control.
Features: 12/24 Hr Clock Format, 4,000+ ON/OFF Events (8 & 16 circuit models only), 99 Holiday Schedules,
and Auto Daylight Savings Time Adjustment. Flexible load control is enhanced by Astro, Variable Pulse, and
Interval options as required for outdoor lighting control, bell ringing and after hours temporary override
respectively. Non-volatile memory maintains all programmed switching times for the life of the time switch.
A factory installed field replaceable lithium battery maintains accurate time keeping and calender information
for a minimum of 8 years.
Specifications
Case – 4-Circuit NEMA 3R – Heavy duty .047" 18 gauge steel in gray finish; 12-1/2" (31.7 cm) High, 8-1/4"
(21.0 cm) Wide, 4" (10.2 cm) Deep. 8-Circuit NEMA 3R - Heavy duty .048" steel in gray finish; 10-3/4"
(27.3 cm) High, 11-1/2" (29.2 cm) Wide, 4-3/4" (12.1 cm) deep with lockable hasp. 16-Circuit NEMA 3R Heavy duty .060" steel in gray finish; 20-5/8" (52.4 cm) High, 13-1/4" (33.7 cm) Wide, 5-1/8" (13.0 cm)
Deep with lockable hasp.
ON/OFF Events – 4-Circuit - 1,000+ Events; 8 & 16-Circuit - 4,000+ Events.
Special Voltages and Cycles – Line voltage models 50 or 60 Hz; Low voltage models 60 Hz 24 Volts.
Switch Rating – Each Pole; 20 amp resistive/general purpose, 12–277 Volts AC; 20 amp resistive/general
purpose, 28 Volts DC; 20 amp ballast, 120–277 VAC; 1 HP, 120 VAC 60 Hz; 98 LRA; 22 FLA; 2 HP,
240 VAC 60 Hz; 80 LRA; 30 FLA; 5 amp tungsten, 120–240 VAC; 470 VA pilot duty, 12–240 VAC; TV-5,
120–240 VAC
Carry-over – Non-volatile memory requires no backup. Time keeping and calender data maintained within
0.01% accuracy for minimum of 8 years with one factory installed, field replaceable lithium coin cell.
Wiring Terminals – #18 to #10 AWG wire.
Applications:
• Schools
• Offices
• Airports
• Stores
• Hotels
• Restaurants
• Factories
• Parks
• Apartments
Engineering Specification
365 Day 8 & 16 Circuit Electronic Astronomic Time Switches
The time switch shall be a solid state electronic control capable of permitting 4000+ ON/OFF set points to be distributed on independent daily
schedules through a 7-day time period and across 99 separate holiday schedules. The time switch shall include a 7-day repeat feature for
simplifying programming of identical set points. The time and set points shall be programmable to the nearest minute with a minimum ON
duration of 1 minute and a maximum ON duration of 6 days, 23 hours, 59 minutes. The timer shall have a digital LED readout to show day-ofweek and time-of-day using 12/24 hour time format. The time switch shall provide a manual override control for both temporary or permanent
For Controlling:
override. Time switch shall operate over a temperature range of -40°F (-40°C) to 155°F (68°C). A non-volatile memory shall maintain all
program data for the life of the time switch without the need for battery backup. The time switch shall include a factory installed lithium battery
• Water Heaters
• Parking Lot Lighting
• Commercial Ovens
• Interior Lighting
• Bells & Signals
• HVAC Equipment
• Fans/Blowers/Pumps
• Livestock Feeders
• Poultry Equipment
• Process Equipment
backup which shall maintain clock time and calendar data for 8 years minimum. Switch configuration to be SPDT for each circuit with a UL 916
Energy Management Equipment listed rating of: Normally Open Contacts Each Pole; 20 amp resistive/general purpose, 12-277 Volts AC;
20 amp resistive/general purpose, 28 Volts DC; 20 amp ballast, 120-277 VAC; 1 HP, 120 VAC 60 Hz; 98 LRA; 22 FLA; 2 HP, 240 VAC 60 Hz;
80 LRA; 30 FLA; 5 amp tungsten, 120-240 VAC; 470 VA pilot duty, 12-240 VAC; TV-5, 120240 VAC| Normally Closed Contacts 10 Amp
Resistive/general purpose, 12-277 VAC; 10 Amp Resistive/general purpose, 28 Volts DC; 3 Amp ballast, 120-277 VAC; 1/4 HP, 120 VAC 60 Hz;
1/2 HP, 240 VAC 60 Hz; 30 LRA; 12 FLA; 275 VA pilot duty, 12-240 VAC. The time switch shall be enclosed in a lockable steel _____ (NEMA 1)
(NEMA 3R) enclosure. The time switch shall be powered by a __________ (user selectable 120, 208, 240 or 277 VAC 50 or 60 Hz)
(24 VAC 60 Hz) source. The time switch shall be INTERMATIC Model ________________ (ET70815CR or ET70815CR24 8-circuit)
(ET71615CR or ET71615CR24 16-circuits).
Model#
UL916
E76987
UL917
C22.2-177
LR3730
2.5 lbs
1.1 kg
-40°F
(-40°C)
to
155°F
(68°C)
ET70415CR1
ET70415CR241
ET70815CR1
ET70815CR241
ET71615CR1
ET71615CR241
1
44
Circuits
Switch
Clock Voltage
Amp Rating
HP Rating
Enclosure
4
4
8
8
16
16
SPDT
SPDT
SPDT
SPDT
SPDT
SPDT
120/208/240/277
24
120/208/240/277
24
120/208/240/277
24
20
20
20
20
20
20
1HP / 2HP
1HP / 2HP
1HP / 2HP
1HP / 2HP
1HP / 2HP
1HP / 2HP
NEMA3R
NEMA3R
NEMA3R
NEMA3R
NEMA3R
NEMA3R
Complies with California Title 24 requirements for multi-level outdoor lighting control.
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Electronic Energy Controls
Next Generation Programming Software
NEXT GENERATION
ACCESSORIES
ET7232M / ET7232M1
RS232 Serial Interface for all Next Generation
Time switches. Also used as remote override for
1 & 2 circuit models.
Unleash the Power of the Next Generation Time Switch!
The NextGen programming software written specifically for installing contractors and maintenance personnel
is the fastest and easiest way to program the Intermatic Next Generation series of electronic time switches.
Features
• Programming of all current Next Generation models (1, 2, 4, 8, & 16 circuits)
• Easy point-n-click programming of holiday and daily event schedules
• File save function for archiving event schedules for future editing and use
• On-line help manual gives easy to follow directions
• One-button time and date programming synchronizes the time switch with your PC's date and time
LAN Connection to a PC
Request Item# 300ET10018
HVAC
156ET9402A
8-Circuit remote override input header. (Not
Pictured)
156ET9403A
16-Circuit remote override input header.
Facility Manager’s Office
Office computers are typically connected through
a local area networks (LANs) which provides an
in-place backbone to allow control of Next
Generation time switches from any linked PC.
This applies to office buildings as well as
distributed facilities such as university or
corporate campuses.
NextGen Distributed Control
Building
Automation
Outdoor Lighting
Control
By linking distributed Next Generation time
switches together with the facility manager’s PC
the time and associated cost of making periodic
schedule changes is greatly reduced and all
timing throughout the network can be
synchronized to the second with the PC’s internal
clock.
Networking capabilities allow programming of the Next Generation time switches
allowing facility managers to make schedule changes from across the building or
campus through an intranet or even across country through the Internet.
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
45
Electronic Energy Controls
Site Lighting Control Panels
SiteMaster Site Lighting Control Panels
These heavy duty lighting control panels are designed for harsh environmental and lighting load conditions.
Features include; Pre-wiring for quick installation, heavy-duty NEMA 3R enclosures, mercury or “Ice Cube”
relays, agency approved disconnect, 40, 80, 120 Amp design, locking hasps, and dead-front storage.
Mechanical or electronic timing, lightning arrester, photo control, and stainless steel options.
SM2200 Series Specifications
Gasketless panel with two 20 Amp DPST Relays. Pre-wired with one 20 Amp double-pole Square D
Homeline™ main breaker. 120 V output: one twin 20 Amp breaker & one single-pole 20 Amp breaker
(for 240 V output- quad breaker with common trip on outside and inside). Capable of controlling
40 Amps @ 120 V and 20 Amps @ 240 V or 12- 400 Watt HID fixtures.
SM4400 Series Specifications
Gasketless panel with two 20 Amp DPST Relays. Pre-wired with one 40 Amp double-pole Square D
Homeline™ main breaker. 120 V output: Six single-pole 20 Amp breakers (240 V output: three double-pole
20 Amp breakers). Capable of controlling 80 Amps @ 120 V and 40 Amps @ 240 V or 24- 400 Watt HID
fixtures.
SM6600 Series Specifications
Gasketless panel with one 60 Amp DPST mercury relay. Split buss service- Upper buss. 120 V output:
Pre-wired with one 60 Amp double-pole Square D Homeline™ main breaker and one-single pole 20 Amp
breaker (240 V output: one 60 Amp double-pole and one 20 Amp double-pole breaker) Lower Buss - for
load connections. Eight single-pole 20 Amp breakers (for 240 V output - four double-pole breakers).
Capable of controlling 120 Amp @ 120 V and 60 Amps @ 240 V or 36- 400 Watt HID fixtures.
SM6240DOT & SM6277DOT Series Specifications
Gasketless 14 AWG stainless-steel panel with 3-point locking system. SM6240DOT: 60 Amp DPST mercury
relay. Split buss service- Upper buss. 120 V output: Pre-wired with one 60 Amp double-pole
Square D Homeline™ main breaker and one single-pole 20 Amp breaker. Lower Buss - for load
connections: Four double-pole 20 Amp breakers. Capable of controlling 60 Amps @ 240 V or 36- 400 Watt
HID fixtures. Pre-installed 15 Amp GFCI duplex convenience receptacle. SM6277DOT: 60 Amp 3PST
mercury relay. Input power 480/277 V 3-Phase: Pre-wired with one 60 Amp 3-Phase main breaker and one
single-phase 20 Amp breaker. Load Output: Six 20 Amp 277 V Single-Phase breakers. Capable of
controlling 180 Amps @ 277 V or 54- 400 Watt HID fixtures.
Applications:
• Schools
• Offices
• Airports
• Stores
• Hotels
• Restaurants
• Factories
• Apartments
• Electrical Utilities
• Municipalities
Engineering Specification
Site Lighting Control Panel
The site lighting control panel shall incorporate agency approved disconnect means with lockout capability, branch circuit breakers for feeding
connected lighting loads, electrically held contactor suitable for switching attached loads, and timing mechanism for control of said contactor.
The control panel shall be pre-wired for installation convenience and reliability. The control panel shall be designed to accept a variety of timing
mechanisms including mechanical and electronic. The control panel and all related
components shall operate over a temperature range of -31°F (-35°C) to 130°F (54°C). The capacity of each branch circuit within the control
panel shall be 20 amps minimum. The control panel shall be a lockable steel NEMA 3R enclosure. The control panel shall be INTERMATIC
Model ________________ (SM2200x-x 2-branch; 4,800 Watt HID) (SM4400x-x 6-branch; 9,600 Watt HID) (SM6600x-x 8-branch; 14,400 Watt
HID) (SM6240DOT) (SM6277DOT).
For Controlling:
• Roadway Lighting
• Parking Structures
• Parking Lots
• Billboards
• Entertainment Venues
• Ball Fields
• Driving Ranges
• Parks
• Outdoor Area Lighting
C22.2-177
LR3730
46
-40°F
(-40°C)
to
130°F
(54°C)
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Electronic Energy Controls
Pre-Wired For Faster Installations
Model#
Time Switch/Description
SM2200*1
SM2200*2
SM2200*3
SM2200*4
SM2200*5
SM2200*6
SM2200*7
SM2200*8
SM2200*16
T103M Mechanical Time Switch
T103M Mechanical Time Switch
ET101CM Electronic Time Switch
ET101CM Electronic Time Switch
ET279C Electronic Time Switch
ET279C Electronic Time Switch
ET104CM Electronic Time Switch
ET104CM Electronic Time Switch
ET8215CM Astronomic Time Switch
Model#
Time Switch/Description
SM4400*1
SM4400*2
SM4400*3
SM4400*4
SM4400*51
SM4400*61
SM4400*7
SM4400*81
SM4400*91
SM4400*10
SM4400*11
SM4400*12
SM4400*13
SM4400*141
SM4400*16
T103M Mechanical Time Switch
T103M Mechanical Time Switch
ET101CM Electronic Time Switch
ET101CM Electronic Time Switch
ET279C Electronic Time Switch
ET279C Electronic Time Switch
ET70115C Electronic Astro Time Switch
ET70215C Electronic Astro Time Switch
ET70215C Electronic Astro Time Switch
T104M Mechanical Time Switch
T104M Mechanical Time Switch
ET104CM Electronic Time Switch
ET104CM Electronic Time Switch
ET70215C Electronic Astro Time Switch
ET8215CM Astronomic Time Switch
Model#
Time Switch/Description
SM6600*1
SM6600*2
SM6600*3
SM6600*4
SM6600*5
SM6600*6
SM6600*71
SM6600*81
SM6600*9
SM6600*101
SM6600*16
T103M Mechanical Time Switch
T103M Mechanical Time Switch
ET101CM Electronic Time Switch
ET101CM Electronic Time Switch
ET104CM Electronic Time Switch
ET104CM Electronic Time Switch
ET279CM Electronic Time Switch
ET279CM Electronic Time Switch
ET70115C Electronic Astro Time Switch
ET70215C Electronic Astro Time Switch
ET8215CM Astronomic Time Switch
1
# Outputs
Output VAC
Photo Control
2
2
2
2
2
2
1
1
2
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
240 VAC
240 VAC
120 VAC
No
Yes
No
Yes
No
Yes
No
Yes
No
# Outputs
Output VAC
Photo Control
4
4
4
4
4
4
4
4
4
2
2
2
2
2
4
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
240 VAC
240 VAC
240 VAC
240 VAC
240 VAC
120 VAC
No
Yes
No
Yes
No
Yes
No
No
Yes
No
Yes
No
Yes
No
No
# Outputs
Output VAC
Photo Control
8
8
8
8
4
4
8
8
8
8
8
120 VAC
120 VAC
120 VAC
120 VAC
240 VAC
240 VAC
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
No
Yes
No
Yes
No
Yes
No
Yes
No
No
No
Two independent circuits for bi-level or 2-sided control. Complies with California Title 24 requirements for multi-level outdoor lighting control
SM2200*7
Standard Steel
Case –
Stainless-Steel
Case S
Lightning Arrestor
Option LA
Lightning Arrester &
Stainless-Steel LAS
SITE LIGHTING PANEL
TIME SWITCH OPTIONS
Mechanical, Electronic, & Astronomic Field
Changeable Mechanisms
Panel Dimensions
SM2200
C22.2-177
LR3730
4.75”
9”
SM4400
C22.2-177
LR3730
17”
SM4400*7
Standard Steel
Case –
Stainless-Steel
Case S
Lightning Arrestor
Option LA
Lightning Arrester &
Stainless-Steel LAS
SM6600*7
Standard Steel
Case –
Stainless-Steel
Case S
Lightning Arrestor
Option LA
Lightning Arrester &
Stainless-Steel LAS
15”
11”
4.75”
SM6600
C22.2-177
LR3730
28”
13”
5”
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
47
In-Wall Electrical Devices
Spring Wound Auto-Off Timers
FD Decorator Series Auto-Off Timers
These energy saving timers use no electricity to operate. These timers are designed to replace any standard
wall switch, single or multi-gang, and automatically limit the “ON” time of fans, lights, motors, heaters and
other energy consuming loads. Time limits of 5, 15, 30 and 60 minutes and 2, 4, 6 and 12 hours are available.
The “hold feature” allows the user to override the automatic shut-off function for extended use of the load as
required. Supplied with a molded white, ivory or almond time dial plate designed to fit either toggle or
decorator style switch plates; single or multi-gang with no field modifications required to fit either style switch
plate. Time saving “up front” terminal connection with teeter type terminals and an easy “press-on” knob
design ensure quick and easy installation.
Specifications
Switch Rating –
Inductive: 20 Amp 125 VAC 50/60 Hz; 10 Amp 250 VAC 50/60 Hz; 10 Amp 277 VAC 50/60 Hz,
Tungsten: 7 Amp 125 VAC,
Motor: 1 HP 125 VAC 50/60 Hz; 2 HP 250 VAC 50/60Hz
Caution: Do not use for sunlamps, sauna, etc...
Colors – Available in White, Ivory, and Almond
Style – Decorator Styling - Can be used with decorator or toggle type switch plates.
Applications:
• Indoor Lighting
• Outdoor Lighting
• Lighting Overrides
• Exhaust Fans
• Whole House Fans
• Ventilating Fans
• Tennis Court Lighting
• Pumps
• Air Conditioners
• Steam Rooms
• Bathroom Fans
• Whirlpools
• Porch Lights
• Broom Closets
• Carriage Lights
• Television Sets
• Self Storage Units
• Engine Block Heaters
• Process Controls
UL916
E76987
C22.2-177
LR3730
Engineering Specification
Spring Wound Auto Shut-Off Timer (a.k.a. Interval Timer).
Provide and install as indicated a mechanical spring wound timer that requires no electricity to operate the timing mechanism. The timer shall
be supplied with a threaded shaft. The timer must be able to fit a standard 2-1/2 inch deep wall box and accept a rectangular decorator wall
plate, standard toggle switch plate or be capable of mounting easily in a panel board. Timer contacts shall break current at the end of timed
cycle. Various timing ranges and switch contact arrangements shall be available up to 12 hours, with or without “HOLD” feature for constant
ON. Timer shall be Intermatic Model FD______ (Fill in for required time range, contact arrangement and color).
Time Cycle
IVORY
without hold with hold
2.5 lbs
1.1 kg
-40°F
(-40°C)
to
155°F
(68°C)
WHITE
without hold with hold
SPST
5 minute
FD5M
N/A
FD5MW
N/A
15 minute
FD15MC
FD15MH
FD15MWC
FD15MHW
30 minute
FD30MC
FD30MH
FD30MWC
FD30MHW
60 minute
FD60MC
FD60MH
FD60MWC
FD60MHW
2 hour
FD2H
N/A
FD2HW
N/A
4 hour
FD4H
N/A
FD4HW
N/A
6 hour
FD6H
FD60HH
FD6HW
FD6HHW
12 hour
FD12HC
FD12HH
FD12HWC
FD12HHW
SPDT Can be used as a normally closed for “Reverse Action” applications
2 hour
FD32H
N/A
FD32HW
N/A
4 hour
FD34H
N/A
FD34HW
N/A
6 hour
FD36H
N/A
FD36HW
N/A
12 hour
N/A
N/A
FD312HW
N/A
DPST
15 minute
FD415M
N/A
N/A
N/A
30 minute
FD430M
N/A
FD430MW
N/A
60 minute
FD460M
N/A
FD460MW
N/A
6 hour
FD46H
N/A
FD46HW
N/A
12 hour
N/A
N/A
N/A
N/A
ALMOND
without hold only
N/A
FD15MAC
FD30MAC
FD60MAC
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Decorator (FD) timers shipped with timer, color coordinated time dial and knob.
48
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
In-Wall Electrical Devices
Spring Wound Auto-Off Timers
FF Commercial Series Auto-Off Timers
These energy saving commercial timers use no electricity to operate. These timers are designed to replace any
standard wall switch, single or multi-gang, and automatically limit the “ON” time of fans, lights, motors,
heaters and other energy consuming loads. Time limits of 5, 15, 30 and 60 minutes and 2, 4, 6 and 12 hours
are available. The “hold feature” allows the user to override the automatic shut-off function for extended use
of the load as required. Rugged time-dial plate takes the abuse encountered in commercial environments.
Time saving “up front” terminal connection with teeter type terminals and an easy “press-on” knob design
ensure quick and easy installation.
Specifications
Switch Rating –
Inductive: 20 Amp 125 VAC 50/60 Hz; 10 Amp 250 VAC 50/60 Hz; 10 Amp 277 VAC 50/60 Hz,
Tungsten: 7 Amp 125 VAC,
Motor: 1 HP 125 VAC 50/60 Hz; 2 HP 250 VAC 50/60Hz
Caution: Do not use for sunlamps, sauna, etc...
Colors – Commercial “brush metal” look.
Style – New simulated metal finish meets NEC requirements.
Engineering Specification
Spring Wound Auto Shut-Off Timer (a.k.a. Interval Timer).
Provide and install as indicated a mechanical spring wound timer that requires no electricity to operate the timing mechanism. The timer shall
be supplied with a threaded shaft. The timer must be able to fit a standard 2-1/2 inch deep wall box with commercial wall plate or be capable of
mounting easily in a panel board. Timer contacts shall break current at the end of timed cycle. Various timing ranges and switch contact
arrangements shall be available up to 12 hours, with or without “HOLD” feature for constant ON. Timer shall be Intermatic Model FF______
(Fill in for required time range and contact arrangement).
Time Cycle
SPST
5 Minute
15 Minute
30 Minute
60 Minute
2 Hour
4 Hour
6 Hour
12 Hour
SPDT
15 Minute
30 Minute
60 Minute
2 Hour
4 Hour
6 Hour
12 Hour
ASHRAE 90.1-1999
Section 9.2.1.2
Space Control
Each space enclosed by ceiling height
partitions shall have at least one control device to
independently control the general lighting within
the space. Each control device shall be activated
either manually by an occupant or automatically
by sensing an occupant.
Each control device shall:
Without Hold
With Hold
Without Hold
FF5M
FF15MC
FF30MC
FF60MC
FF2H
FF4H
FF6H
FF12HC
FF5MH
FF15MH
FF30MH
FF60MHC
N/A
N/A
FF6HH
FF12HHC
DPST
N/A
FF415M
FF430M
FF460M
N/A
N/A
FF46H
FF412H
FF315M
FF330M
FF360M
FF32H
FF34H
FF36H
FF312H
N/A
N/A
N/A
FF32HH
FF34HH
N/A
FF312HH
With Hold
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
(a) control a maximum of 2,500 sq ft area for a
space 10,000 sq ft or less and a maximum
of 10,000 sq ft area for a space greater than
10,000 sq ft,
(b) be capable of overriding the shutoff control
required in 9.2.1.1 for no more than four
hours, and
(c) be readily accessible and located so the
occupant can see the controlled lighting for
a maximum of four hours.
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
49
In-Wall Electrical Devices
Electronic Auto-Off Timers
EI200 Series Decorator Electronic Auto-Off Timer
The EI200 series timers provide silent operation in time ranges from 30 minutes up to 12 hours. Four basic
models available in three colors reduce the need to stock as many timers, freeing up shelf space and providing
more specification flexibility. Replaces single-pole switches in a variety of applications.
Specifications
ASHRAE 90.1-1999
Section 9.2.1.2
Space Control
Each space enclosed by ceiling height partitions
shall have at least one control device to
independently control the general lighting within
the space. Each control device shall be activated
either manually by an occupant or automatically
by sensing an occupant.
(a) control a maximum of 2,500 sq ft area for
a space 10,000 sq ft or less and a
maximum of 10,000 sq ft area for a space
greater than 10,000 sq ft,
(b) be capable of overriding the shutoff
control required in 9.2.1.1 for no more
than four hours, and
(c) be readily accessible and located so the
occupant can see the controlled lighting
for a maximum of four hours.
-32°F
(0°C)
to
158°F
(70°C)
Engineering Specification
Electronic Auto Shut-Off Timer (a.k.a. Interval Timer).
Provide and install as indicated an electronic timing mechanism. The timer shall be supplied with an LED display and single-button operation.
The timer must be able to fit a standard wall box and accept a rectangular decorator wall plate. Timer contacts shall break current at the end of
timed cycle. Timer shall be capable of single-pole operation. Various user selectable timing ranges shall be available up to 12 hours, with or
without “HOLD” feature for constant ON. Timer shall be Intermatic Model ______ (For 5/10/15/30 Minute EI200 - Ivory, EI200W - White,
EI200LA - Light Almond; For 10/20/30/60 Minute EI210 - Ivory, EI210W - White, EI210LA - Light Almond; For 1/2/4/8 Hour EI220 - Ivory,
EI220W - White, EI220LA - Light Almond; For 2/4/8/12 Hour EI230 - Ivory, EI230W - White, EI230LA - Light Almond).
Each control device shall:
UL916
E76987
Switch – Single-pole
Switch Rating –
Resistive (heater): 15 Amp, 120 VAC 1800 Watts;
Tungsten (incandescent): 8.3 Amp, 120 VAC 1000 Watts;
Ballast (Fluorescent): 8 Amp, 120 VAC;
Motor: 1/4 H.P., 120 VAC;
Caution: Do not use for sunlamps, sauna, etc...
Colors – Available in White, Ivory, and Light Almond
Style – Decorator Styling.
Special Voltages and Cycles – 50 or 60 Hz.
2.5 lbs
1.1 kg
Model#
Time Range
Switch
EI200
EI200W
EI200LA
EI205*
EI205W*
EI205LA*
EI210
EI210W
EI210LA
EI215**
EI215W**
EI215LA**
EI220
EI220W
EI220LA
EI230
EI230W
EI230LA
5/10/15/30 Minute
5/10/15/30 Minute
5/10/15/30 Minute
5/15/30/45/60 Minute
5/15/30/45/60 Minute
5/15/30/45/60 Minute
10/20/30/60 Minute
10/20/30/60 Minute
10/20/30/60 Minute
15/30/60 Minute, 2/4Hour
15/30/60 Minute, 2/4Hour
15/30/60 Minute, 2/4Hour
1/2/4/8 Hour
1/2/4/8 Hour
1/2/4/8 Hour
2/4/8/12 Hour
2/4/8/12 Hour
2/4/8/12 Hour
Single-Pole
Single-Pole
Single-Pole
Single-Pole
Single-Pole
Single-Pole
Single-Pole
Single-Pole
Single-Pole
Single-Pole
Single-Pole
Single-Pole
Single-Pole
Single-Pole
Single-Pole
Single-Pole
Single-Pole
Single-Pole
Clock Voltage
Max
Wattage
Color
HOLD
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
1,800
1,800
1,800
1,800
1,800
1,800
1,800
1,800
1,800
1,800
1,800
1,800
1,800
1,800
1,800
1,800
1,800
1,800
Ivory
White
Light Almond
Ivory
White
Light Almond
Ivory
White
Light Almond
Ivory
White
Light Almond
Ivory
White
Light Almond
Ivory
White
Light Almond
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
* Meets or exceeds CEC Title 24, ASHRAE 90.1 and IECC requirements for enclosed spaces.
** Meets or exceeds ASHRAE 90.1 Requirements for enclosed spaces.
50
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
In-Wall Electrical Devices
24-Hour Mechanical Time Switches
Compact Mechanical In-Wall Time Switches
These compact heavy-duty 24-hour timers can be used to turn on lights, fans, pumps and other heavy-duty
loads for energy savings, security and convenience. Its compact, quiet, low profile design has easy to set tabs
for precise 24-hour control. Models are available for single gang, 2-gang and dual timer applications. Easy
set tabs provide for minimum on/off times of 20 minutes for up to 36 ON/OFF events daily. A manual ON or
OFF override provides for permanent on or off override of loads at any time.
Three models; E1120 - a single timer model, E1220 - a single timer with a 2-gang switch plate for a toggle
switch, and E1221 - a single timer with a 2-gang switch plate for a decorator switch. All four models include
a white metal single or 2-gang switch plate as required. The toggle or decorator switch is not included with
timers. Model E1221 with decorator switch plate can be wired to control a decorator style receptacle or GFCI
receptacle to provide for “timed receptacle” control.
Size – All models 1-1/4" (3.18 cm) Deep. Model E1120 - 4-1/2" (11.43 cm) H, 2-3/4" (6.99 cm) W; Models
E1220, E1221 and E1222 - 4-1/2" (11.43 cm) H, 4-9/16" (11.59 cm) W.
Switch Rating – 120 Volt AC, 60 Hz, 15 Amps, 1875 Watts Resistive 1350 Watts Tungsten, 1/2 HP Motor
Load, 8 Amp Inductive
Manual Control – Timers can be turned on and off manually for temporary or permanent control.
Color – White switch plate and trippers, black dial.
Plate Only
E1120
E1220
E1221
24EB5495
24EB5497
24EB5524
Interior lighting in buildings larger than 5,000
sq. ft. shall be controlled with an automatic
control device to shut off building lighting in all
spaces.
This automatic control device
shall function on either;
Specifications
Model#
ASHRAE 90.1-1999
Section 9.2.1.1
Automatic Lighting Shutoff
Switch
Volts /60Hz
Amps
Max
Wattage
Min. On/Off Time
Max. On/Off Time
SPST
SPST
SPST
120
120
120
15
15
15
1875
1875
1875
20 mins.
20 mins.
20 mins.
23 hrs. 40 mins.
23 hrs. 40 mins.
23 hrs. 40 mins.
(a) a time-of-day operated control
device that turns lighting off at
specific programmed times, and
independent program schedule shall
be provided for areas of no more
than 25,000 sq ft but not more than
one floor or
(b) an occupant sensor that shall turn
lighting off within 30 minutes of an
occupant leaving a space or
(c) by occupant intervention.
Heavy Duty In-Wall Time Switches
UL916 C22.2-177 2.5 lbs
E76987 LR3730 1.1 kg
These heavy duty timers can be used to turn on lights, fans, pumps and other heavy duty loads for energy
savings, security and convenience. The timer is designed to mount to any standard junction box for replacing
a wall switch. Models are available in single ON / OFF or multiple ON / OFF type. Both models have an easy
to use manual override.
Model E1010 equipped with a 24 hour dial divided in half-hour increments with a permanently attached “ON”
and “OFF” tripper permitting single “ON / OFF” control every 24 hours. Model E1020 equipped with a multiple
program dial. The dial accommodates 12 “ON” and 12 “OFF” trippers. Furnished with two “ON” and two “OFF”
trippers. Both timers have three color code leads and require a hot, neutral and one side of the load.
Applications: For Controlling:
Specifications
Size – 4-1/4" (10.8 cm) High, 3-1/4" (9.5 cm) Wide, 1-3/8" (3.5 cm) Deep.
Switch Rating – 120 VAC 60 Hz; 1440 Watts Tungsten; 12 Full load Amps.; 15 Amp max load.
Timing Cycle – Minimum “ON” time 1/2 hour, maximum “ON” time 22-1/2 hours; Minimum time between
any two “ON” trippers (and any two “OFF” trippers) is 2 hours.
Model#
E1010
E1020
Switch
Volts
Amps
Max
Wattage
Color
SPST
SPST
120
120
15
15
1800
1800
Stonedust white housing
Stonedust white housing
• Schools
• Offices
• Airports
• Stores
• Hotels
• Restaurants
• Parks
• Apartments
For additional trippers for E1020 (2 “ON” / 2 “OFF” per pack), order No. 156EB1945A.
• Hall Lights
• Ceiling Lights
• Whole House Fans
• Paddle Fans
• Porch Lights
• Outdoor Lights
• Air Conditioners
• Coffee Makers
• Boilers
• Attic Fans
• Industrial Fans
• Automated Control
UL917
2.5 lbs
C22.2-177 1.1 kg
LR3730
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
51
In-Wall Electrical Devices
24-Hour Mechanical Time Switches
EI500 Series Decorator Digital 7-Day Time Switch
The EI500 series compact 7-day timers provides up to 7-ON and 7-OFF operations per week which can be
used for 24-hour or 7-day load control of lights, fans, pumps, and other medium-duty loads for energy
savings, security, and convenience. Its compact, quiet, low profile design is easy to program for to-the-minute
24-hour or 7-day control. In addition, the display continuously shows time of day, day of the week, timer load
and the load status. Available in three colors white, ivory, and light almond. Replaces single-pole switches
in a variety of applications.
Specifications
ASHRAE 90.1-1999
Section 9.2.1.1
Automatic Lighting Shutoff
Interior lighting in buildings larger than 5,000
sq ft shall be controlled with an automatic
control device to shut off building lighting in all
spaces.
Switch – Single-pole
Switch Rating –
Resistive (heater): 15 Amp, 120 VAC 1800 Watts;
Tungsten (incandescent): 8.3 Amp, 120 VAC 1000 Watts;
Ballast (fluorescent): 8 Amp, 120 VAC;
Motor: 1/4 H.P., 120 VAC;
Caution: Do not use for sunlamps, sauna, etc...
Events – 7 ON & 7 OFF Events per Day.
Colors – Available in White, Ivory, and Light Almond
Style – Decorator Styling.
Special Voltages and Cycles – 50 or 60 Hz.
Engineering Specification
Electronic 7-Day Timer.
This automatic control device
shall function on either;
(a) a time-of-day operated control device
that turns lighting off at specific
programmed times, and independent
program schedule shall be provided for
areas of no more than 25,000 sq ft but
not more than one floor or
(b) an occupant sensor that shall turn
lighting off within 30 minutes of an
occupant leaving a space or
(c) by occupant intervention.
UL916
E76987
52
32°F
(0°C)
to
158°F
(70°C)
The timer switch shall be a solid state electronic control capable of permitting 7-ON and 7-OFF set points to be distributed through a
7-day time period. The time and set points shall be programmable to the nearest minute with a minimum ON duration of 1 minute and a
maximum ON duration of 6 days, 23 hours, 59 minutes. The timer shall have a backlit digital LCD readout to show day-of-week and time-of-day
using 12 hour AM/PM indicator. The time switch shall provide a manual override control for both temporary or permanent override.
Time switch shall operate over a temperature range of 32°F (0°C) to 158°F (70°C). An internal rechargeable battery shall protect program
information and time-of-day for a minimum of 36 hours. Switch configuration to be SPST with a UL listed rating of: 20 amp Resistive,
120 Volts AC, 50/60 Hz; 15 amps Resistive, 120 Volts AC, 50/60 Hz; 1/4 HP, 120 Volts AC, 50/60 Hz; 8.3 amps Tungsten, 120 Volts AC,
50/60 Hz; 10 amps Ballast, 120 Volts AC, 50/60 Hz The timer must be able to fit a standard wall box and accept a rectangular decorator wall
plate. Timer contacts shall make or break current according to user adjustable program. Timer shall be Intermatic Model ______ (Ivory - EI500,
White - EI500W, Light Almond - EI500LA)
Model#
Switch
Clock Voltage
Max
Wattage
Color
EI500C
EI500WC
EI500LAC
Single-Pole
Single-Pole
Single-Pole
120 VAC 50/60 Hz
120 VAC 50/60 Hz
120 VAC 50/60 Hz
1,800
1,800
1,800
Ivory
White
Light Almond
2.5 lbs
1.1 kg
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
In-Wall Electronic Devices
7-Day Electronic Time Switch
EI600 Series Decorator Electronic 7-Day Astro Time Switch
This easy to program timer provides up to 40 ON/OFF operations per week which can be used for 24-hour or
7-day load control. The astronomic feature provides sunset ON and sunrise OFF settings and the auto daylight
savings adjustment means you can “set-it and forget-it”. The independant 7-day programming provides
complete flexibility for applications where load switching differs each day of the week. Astronomic
programming can be combined with independant programs to provide a sunset ON and timed OFF program.
A factory supplied CR2 lithium battery provides up to three years of time keeping without AC power and user
program selections are stored in non-volatile memory. A low battery indicator appears in the display when the
battery requires replacement. In addition, the display continuously shows time of day, day of the week, timer
load and the load status. The timer has an isolated single pole single throw switch which allows the timer to
switch any load type, including PAR lamps and motor loads from 12 to 277 volts AC or 12 to 28 volts DC,
within the specified ratings. A “3 wire” design allows the timer to replace, or be used as a single-pole or 3way (multi-way) switch.
Applications:
Specifications
• Schools
• Offices
• Airports
• Stores
• Hotels
• Restaurants
• Parks
• Apartments
Switch – Single-pole or 3-way (Multi-way) Compatable
Switch Rating –
Resistive (heater): 20 Amp, 120-277 VAC
Tungsten (incandescent): 15 Amp, 120 VAC; 6 Amp, 208-277 VAC
Ballast (fluorescent): 16 Amp, 120-277 VAC
Motor: 1 H.P., 120 VAC; 2 H.P., 240 VAC; 4 Amp, DC Loads:12 VDC; 2 Amp, 28 VDC
Caution: Do not use for sunlamps, sauna, etc...
Events – 40 ON/OFF Events per week.
Colors – Available in White, Ivory, and Light Almond
Style – Decorator Styling.
Special Voltages and Cycles – 50 or 60 Hz.
Warranty – 5 Years
For Controlling:
Engineering Specification
Electronic 7-Day astronomic Timer.
The timer switch shall be a solid state electronic control capable of permitting 40 ON/OFF set points to be distributed through a
7-day time period with 1 astro ON and 1 astro OFF set point per day. The time and set points shall be programmable to the nearest minute with
a minimum ON duration of 1 minute and a maximum ON duration of 6 days, 23 hours, 59 minutes. The timer shall have a digital LCD readout
to show day-of-week and time-of-day using 12 hour AM/PM indicator. The time switch shall provide a manual override control for both
temporary or permanent override.
Time switch shall operate over a temperature range of 32°F (0°C) to 104°F (40°C). A lithium battery provides up to three years of time keeping
without AC power and user program selections are stored in a non-volatile memory. Switch configuration to be SPST with a UL listed rating of:
• Indoor Lighting
• Outdoor Lighting
• Pumps & Fans
• HID Lighting
• Library Lights
• Classroom Lights
• Fluorescent Lighting
• PAR Lights
• Heaters
• Recreational Vehicles
• Air Conditioners
• Porch Lights
• Carrage Lights
Resistive (heater): 20 Amp,120-277 VAC; Tungsten (incandescent):15 Amp, 120 VAC; 6 Amp, 208-277 VAC; Ballast (Fluorescent): 16 Amp,
120-277 VAC; Motor: 1 H.P., 120 VAC; 2 H.P., 240 VAC; 4 Amp, DC Loads: 12 VDC; 2 Amp, 28 VDC. The timer must be able to fit a standard
wall box and accept a rectangular decorator wall plate. Timer contacts shall make or break current according to user adjustable program. Timer
shall be Intermatic Model ______ (Ivory - EI600, White - EI600W, Light Almond - EI600LA)
UL917
C22.2-177
LR3730
Model#
Switch
Contact
Max
Wattage
Color
EI600C
EI600WC
EI600LAC
Single-Pole / 3-way
Single-Pole / 3-way
Single-Pole / 3-way
12 - 277 VAC;12 - 28 VDC
12 - 277 VAC;12 - 28 VDC
12 - 277 VAC;12 - 28 VDC
1,800 - 4,155
1,800 - 4,155
1,800 - 4,155
Ivory
White
Light Almond
32°F
(0°C)
to
158°F
(70°C)
2.5 lbs
1.1 kg
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
53
InTouch Wireless Controls™
Wireless Home Controls
InTouch™ — The Centerpiece for Peaceful Living
Z-wave™ makes reliable wireless home control possible. Intermatic makes it a reality with the InTouch™ series
of wireless controls. Until now home controls had only two options — reliable controls that were too
expensive or low cost controls that were unreliable. That’s all changed with Intermatic’s InTouch wireless
controls, which bring reliable controls together with low cost to deliver a home solution everyone can enjoy.
Named the Best New Emerging Technology by CNET at the 2006 Consumer Electronic Show, and recipient of
the Electronic House Product of the Year Award, Z-wave is a breakthrough technology that enables products
from many different manufacturers to seamlessly work together. This same technology lies at the center of
Intermatic’s InTouch home control system.
Several factors contribute to make Z-wave a breakthrough innovation. First is the “mesh” network, which
basically means that every line-powered device within the network acts as a repeater to route signals among
distant devices. Second is that Z-wave networks operate in the 900Mhz band, providing a penetrating signal
to deliver reliable communications between devices. Another factor is that with more than 4 billion unique
house codes, Z-wave provides a secure network with no fear of interference from neighboring systems. Finally,
Z-wave has made the leap from theory to reality as more than 100 companies are working in the Z-wave
Alliance to develop actual products that benefit homeowners today and in the near future.
What this means to homeowners, is they now have all of the convenience, comfort and safety of a reliable home
control system without concerns of system reliability, product/ installation costs or compatibility between
products.
The Intermatic InTouch system helps homeowners “set the scene” for entertaining, working or just relaxing
after a long day. Homeowners can now manage and monitor lighting, security systems and other electronics
easily, conveniently and securely from anywhere in the world. Functions such as indoor and outdoor
lighting, entry access, pool & spa functions, home theater systems, window treatments and
heating & cooling are a breeze with Intermatic’s InTouch control system.
54
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
InTouch Wireless Controls™
Wireless Home Controls
Intermatic’s InTouch system has taken Z-wave technology to an even higher level of functionality with the introduction of its patent pending InTouch server technology. The InTouch server provides full two-way, real-time
status of every device in the network including legacy Z-wave devices. The InTouch server also makes a host
of never before seen features available to the installer and homeowner including:
• Greater network range – doubling the number of “hops” a signal can take to get to its target from the Z-wave standard
of 4 to 8
• In-field firmware upgrade capability – future-proofing an InTouch network from protocol changes
• System text and graphics messaging – allowing streaming information such as sports scores, stock quotes, weather
and news alerts as well as personal and system status messages
• Centralized scene and status information – ability to remotely edit scenes from anywhere in the network
• Full Z-wave compatibility – adding an InTouch Server to any manufacturer’s Z-wave product instantly upgrades their
capabilities to share many of the InTouch features
Imagine arriving home from a long day’s work and as you step inside, the temperature of the room is just right,
the lighting level is relaxed and inviting, your audio system is playing your favorite song, the shades are being
drawn for the evening and your spa is warm and bubbling.
At Intermatic, we call this living the InTouch lifestyle. Previous home controls systems capable of providing a
similar level of service as InTouch were expensive, took weeks to install and didn’t deliver the same
functionality.
InTouch provides the safety, security and convenience homeowners are looking for while making it priceaccessible for everyone. With an InTouch residential controls package from Intermatic, electrical contractors,
designers, home builders and custom installers can provide homeowners with a robust and intelligent system
for a fraction of the cost of current competitive systems. Best of all, the system can be expanded easily to grow
with homeowners’ changing needs. And since it’s powered by Z-wave technology, InTouch is 100% compatible
with the growing number of Z-wave enabled products.
InTouch products are backed by a 10-year warranty and more than 115 years of experience in the electrical
industry. The controllers, switches and receptacles are designed to complement any décor and the intuitive
controls are designed for minimal programming effort and maximum system functionality.
For the Professional installer:
• Earn back lost sales by offering customers an affordable, full-bodied system at a price that will shock them for being so
affordable.
• Easy Installation equals less spent on time and labor.InTouch devices install with existing wiring and both network
setup and system programming are quick and easy.
• Fewer SKUs means less inventory. Intermatic’s growing line of InTouch products offer changeable faceplates and
combination switches to keep the number of devices the distributor or installer needs to inventory to a minimum.
• Adaptability makes InTouch the perfect solution for new construction as well as retrofit applications.
For the Homeowner:
• Advanced technology fosters a progressive lifestyle at a price anyone can afford.
• Home controls add value to the home, increasing prestige and resale values.
• Reliable and secure control network for consistent comfort, convenience and safety.
• Energy savings brought about by improved electrical management.
• Easily modified as your electronic needs change and grow.
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
55
InTouch Wireless Controls™
Wireless Home Controls
InTouch™ Residential and Small Business Applications
CA3000
Lighting
Control
CA5000
Multi-Scene
Control
CA9000
Motion
Control
CA3500
Appliance
Control
CA600
Dimming
Control
CA5100
Multi-Point
Control
CA3750
Heavy Load
Control
56
CA5500BR
Portable Command
CA7100
Central Command
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
InTouch Wireless Controls™
Wireless Home Controls
CA7100
InTouch™ Product Line
CA7100
CA600
In-Wall Master Control
Wall Dimmer Switch
• Features include multiple scene functions, programming
based on time, action or a combination of both, along
with a full 2-way control system
• Built-in astro clock allows lights to go on at sunset and
off at sunrise, never having to reset the timer
• Voltage: 120 volts 50/60 Hz
• Agency approval: FCC, CSA c/us
• Offers local and remote scene control,
ON/OFF/dim/bright features and LED feedback
• The 3-way option allows consumers to control lights
from multiple locations, using standard switches, and
the mini-scene function allows a light switch to also
trigger a small scene of up to five additional devices
• Includes three interchangeable faceplates
• Colors include White, Ivory and Light Almond
• Voltage: 120 volts 50/60 Hz
• Rating: 600 W Tungsten
• Agency approval: FCC, CSA c/us
CA5500BR
Hand Held Remote with Smartbase
• Offers remote scene control, status feedback and a
rechargeable nickel metal hydride battery
• The Smartbase also features network memory backup
• Agency approval: FCC
CA5000
Multi-Button Scene Controller
• Offers remote scene control and status feedback
• Includes three interchangeable faceplates
• Colors include White, Ivory and Light Almond
• Voltage: 120 volts 50/60 Hz
• Agency approval: FCC, CSA c/us
Wall Switch
• Includes local and remote scene control, ON/OFF, 3-way
option and mini-scenes
• Includes three interchangeable faceplates
• Colors include White, Ivory and Light Almond
• Voltage: 120 volts 50/60 Hz
• Rating: 1800 Watts 15A Tungsten;
1800 Watts 15A Resistive/Inductive;
1820VA 15A Ballast; 1/2HP Motor
• Agency approval: FCC, CSA c/us
CA3500
Accessory Wall Controller
Split-Duplex Receptacle
CA9000
CA600
CA5000
CA3000
CA5100
CA3500
CA9000
CA3750
CA3000
CA5100
• Features include remote scene control, and mini-scenes
• Includes three interchangeable faceplates
• Colors include White, Ivory and Light Almond
• Voltage: 120 volts 50/60 Hz
• Agency approval: FCC, CSA c/us
CA5500BR
• Features one controlled grounded receptacle and local
control
• Includes three interchangeable faceplates
• Colors include White, Ivory and Light Almond
• Voltage: 125 volts 50/60 Hz
• Rating: 15 Amps General Purpose
• Agency approval: FCC, CSA c/us
CA3750
Wireless PIR Sensor
• Features remote scene control and adjustable time delay
• Requires three AA alkaline batteries
• Agency approval: FCC
Contactor Module
• For large loads such as air conditioners, spas and
heaters, the contactor module features a local ON/OFF
control and LED feedback
• Voltage: 120, 208, 240, 277 volts 50/60 Hz
• Rating: 6600 Watts 30 A Resistive;
5500VA 25 Amps Inductive;
5540 Watts 20 Amps @ 277VAC Ballast;
4400 Watts 20 Amps Tungsten;
3HP @ 220VAC Motor
• Agency approval: FCC, CSA c/us
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
57
Your Total Professional Solution
Whether you are looking to light a garden pathway or signs
along the highway, Intermatic has a comprehensive line
of professional lighting to suit your every need.
Intermatic recently introduced its line of High
Intensity Discharge (HID) lighting to satisfy
the growing demand for high quality
industrial lighting. With the same high
quality that you’ve come to expect
from Intermatic controls, Intermatic
HID lighting can withstand the
harshest elements while providing
constant and reliable operation.
When married with Intermatic
switches and other HID control
features like time clocks and
photo controls, Intermatic
provides a total lighting
solution from beginning to
end.
Intermatic’s Light Expressions™
series of low voltage lighting
fixtures is a professional grade
series of landscape lighting that
blends superior styling with
extreme durability. The Light
Expressions™ line offers
contractors and landscape
designers a high-end family of
landscape fixtures and transformers
to dramatically enhance the
appearance of the home, while adding
safety and security. With Light
Expressions™, one may highlight architecture,
trees, sculpture, decks, paths and more.
58
Professional Grade Transformers
A
Intermatic® professional grade transformers are the most reliable low voltage transformers available.
Manufactured by Intermatic Incorporated – recognized worldwide for high quality timers and system controls
– these transformers are especially designed for trouble-free operation and long lasting durability.
Ensure that all of your professional lighting installations operate trouble-free and provide long-lasting service
by using only Intermatic® professional grade transformers.
“Your success can depend on it!”
B
Every professional grade transformer includes these important product features:
• Heavy gauge steel housings with rain-tight covers (Model AL60TW uses a high impact polymer construction)
• Complete ground shield protection for safe operation. Suitable for use with submersible luminaries or submersible pumps
• Suitable for use with submersible luminaries or submersible pumps
• Meets UL and cCSAus safety standards
• Automatic or resettable circuit breakers for overload protection, helps prevent damage to electrical components, caused by overheating
A. AL300TPWS
• Heavy-duty 16 ga. stainless steel
case
• Built-in photo control option
• Manual ON/OFF switch
• Fully programmable timer
• One set of 300 watt terminal blocks
• Heavy-duty power cord
• 5 Year limited warranty
• Resettable circuit breaker
• Rain tight enclosure with lifetime
limited warranty
B. AL600TPWS
• Heavy-duty 16 ga. stainless steel
case
• Built-in photo control option
• Manual ON/OFF switch
• Fully programmable timer
• Two sets of 300 watt terminal
blocks
• Heavy-duty power cord
• 5 year limited warranty
• Resettable circuit breaker
• Rain tight enclosure with lifetime
limited warranty
C. AL900TPWS
• Heavy-duty 16 ga. stainless steel
case
• Built-in photo control option
• Manual ON/OFF switch
• Fully programmable timer
• Three sets of 300 watt terminal
blocks
• Heavy-duty power cord
• 5 year limited warranty
• Resettable circuit breaker
• Rain tight enclosure with lifetime
limited warranty
C
D
D. AL300RTW
E. AL600TW
• Heavy-duty 18 ga. steel housing
• Manual ON/OFF switch
• Fully programmable timer
• One set of 300 watt terminal blocks
• Heavy-duty power cord
• 5 year limited warranty
• Automatic circuit breaker
• Rain tight enclosure
• Heavy-duty 18 ga. steel housing
• Manual ON/OFF switch
• Fully programmable timer
• Two sets of 300 watt terminal
blocks
• Heavy-duty power cord
• 5 year limited warranty
• Automatic circuit breaker
• Rain tight enclosure
F. AL900TW
• Heavy-duty 18 ga. steel housing
• Manual ON/OFF switch
• Fully programmable timer
• Three sets of 300 watt terminal
blocks
• Heavy-duty power cord
• 5 year limited warranty
• Automatic circuit breaker
• Rain tight enclosure
F
E
All Intermatic AL Transformers meet UL1838 Standards
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
59
Professional Grade Transformers
G. AL60TW
G
H. AL300MTW
• High-impact polymer case
• Manual ON/OFF switch
• Fully programmable timer
• 2 sets of ON/OFF trippers
• Automatic circuit breaker
• Ground shield protection
• Heavy-duty power cord
• 5 year limited warranty
• Rain tight enclosure
TRANSFORMER:
• 300VA (True Watts) multi-tap
(12V, 13V, 15V)
• Heavy 18 ga. painted steel housing
• Resettable circuit breaker
• Heavy duty power cord code
compliant for use with submersible
luminaries
• Easy hook-up to color coded and
labeled leads
• Conduit ready with knockouts
• 10 year limited warranty on
transformer
• 600VA (True Watts) multi-tap
(12V, 13V, 15V)
• Heavy 18 ga. painted steel housing
• Resettable magnetic circuit
breakers (2)
• Heavy duty power cord code
compliant for use with submersible
luminaries
• Easy hook-up to color coded and
labeled leads
• Conduit ready with knockouts
• 10 year limited warranty on
transformer
INDEPENDENT DIGITAL SELF
ADJUSTING INDOOR TIMER:
• Set it once, no re-setting required
• Automatically adjusts
sunrise/sunset times
• Automatically adjusts for daylight
savings time
• Battery back-up included
• Easy to read LCD display
• One year limited warranty on timer
H
I. AL600MTW
TRANSFORMER:
INDEPENDENT DIGITAL SELF
ADJUSTING INDOOR TIMER:
• Set it once, no re-setting required
• Automatically adjusts
sunrise/sunset Times
• Automatically adjusts for daylight
savings time
• Battery back-up included
• Easy to read LCD display
• One year limited warranty on timer
J. AL300BW
I
• High-impact PVC case
• Water tight enclosure, can be buried
to ground level
• Can be controlled externally
• Three 1.5” I.D. knockouts for line
voltage conduit
• Automatic circuit breaker
• Ground shield protection for safe
operation
• 5 year limited warranty
J
All Intermatic AL Transformers meet UL1838 Standards
60
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Professional Landscape Lighting
Our Professional Grade Lighting line includes a wide range of weatherproof transformers, low voltage fixtures,
specialty insulated cables and a variety of accessories. Intermatic offers an expanded selection of fixtures
designed for easy installation. All have the most advanced features that result from our many years of
experience in low voltage lighting.
AL111
AL115
AL375V
AL380C
Well Light with 14W
Poly-Star bulb
Submersible Light
with 20W halogen
MR16 bulb
Metal Light with 18W
wedge base bulb and
Verde finish
Copper Light with
18W wedge base bulb
Accessories
Low Voltage Cable
AL10210
10/2 100 ft.
AL102-5C
10/2 500 ft.
AL12210
12/2 100 ft.
AL385V
AL395
AL395V
AL401
Brass Light with 18W
wedge base bulb and
Verde Patina finish
Brass Light with 18W
wedge base bulb and
Aged Brass finish
Brass Light with 18W
wedge base bulb and
Verde Patina finish
Metal Floodlight with
35W MR16 bulb and
Black finish
AL122-5C
12/2 500 ft.
AL8-12
Designed specifically
for weatherproof,
outdoor, hard-wire
installations
AL1160
AL402
AL402TA
AL403
AL403TA
Metal Floodlight with
50W PAR36 bulb and
Black finish
Metal Floodlight with
50W PAR36 bulb and
Textured Architectural
Bronze finish
Metal Floodlight with
35W Halogen MR16
bulb and Black finish
Metal Floodlight with
35W Halogen MR16
bulb and Textured
Architectural Bronze
finish
Fixture Ground Stake,
1/2” Female Thread,
Heavy Duty Plastic
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
61
Professional Landscape Lighting
62
AL405
AL405V
AL406
AL406TA
Brass Light with 18W
wedge base bulb and
Aged Brass finish
Brass Light with 18W
wedge base bulb and
Verde Patina finish
Metal Deck Light with
8W bayonet bulb and
Black finish
Metal Deck Light with
8W bayonet bulb and
Textured Architectural
Bronze finish
AL407TA
AL408TA
AL409
AL409TA
Metal Cone Walk
Light with 18W
wedge base bulb and
Textured Architectural
Bronze finish
Metal Dome Walk
Light with 18W
wedge base bulb and
Textured Architectural
Bronze finish
Metal Bollard Light
with 50W MR16 bulb
and Black finish
Metal Bollard Light
with 50W MR16 bulb
and Textured
Architectural Bronze
finish
AL425C
AL501
AL502
AL502DS
Copper Ellipse Light
with 18W wedge base
bulb
Mini Floodlight with
35W halogen MR16
bulb and Black finish
Large Floodlight with
50W PAR36 bulb and
Black finish
Large Floodlight with
50W PAR36 bulb and
Dark Sand finish
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Professional Landscape Lighting
AL502TA
AL506
AL508V
AL510V
Large Floodlight with
50W PAR36 bulb and
Architectural Bronze
finish
Metal Floodlight with
35W halogen MR16
bulb and Black finish
Large Path Light with
18W wedge base bulb
and Verde finish
Large Brass
Floodlight with 50W
PAR36 bulb and
Verde finish
AL521
AL550
AL550DS
AL550TA
Cast Metal Acorn
Style Path Light with
35W halogen MR16
bulb and Black finish
3 Tier Path Light with
18W wedge base bulb
and Black finish
3 Tier Path Light with
18W wedge base bulb
and Dark Sand finish
3 Tier Path Light with
18W wedge base bulb
and Architectural
Bronze finish
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
63
High Intensity Discharge (HID) Lighting
Intermatic’s line of HID lighting is the perfect solution for a wide variety of outdoor lighting needs. In addition,
Intermatic has a full array of controls and sensors designed to complement any residential, commercial or
industrial lighting system.
Wall Packs
Ideal for: Parking Areas, Entrances, Walkways, Underpasses, Loading Docks, Recreation Areas and Tunnels.
• UL listed for wet locations
• Heavy duty die-cast aluminum powder coating construction
Part Number
WL050MH
WL070MH
WL100MH
WL150MH
WL175MH
WL250MH
WL400MH
64
WL035HPS
WL050HPS
WL070HPS
WL100HPS
WL150HPS
WL250HPS
WL400HPS
• Corrosion-resistant hardware
• 1/2” tapped holes available for installing photocell (photocell
optional)
Wattage
Lamp
Voltage
Finish
Lens
WL035HPS
WL050HPS
35W
50W
High Pressure Sodium
High Pressure Sodium
Bronze
Bronze
Polycarbonate
Polycarbonate
WL050MH
50W
Metal Halide
Bronze
Polycarbonate
WL070HPS
70W
High Pressure Sodium
Bronze
Polycarbonate
WL070MH
70W
Metal Halide
Bronze
Polycarbonate
WL100HPS
100W
High Pressure Sodium
Bronze
Glass
WL100MH
100W
Metal Halide
120V
120V
120/208/240/277V
Quad Tap
120/208/240/277V
Quad Tap
120/208/240/277V
Quad Tap
120/208/240/277V
Quad Tap
120/208/240/277V
Quad Tap
Bronze
Glass
WL150HPS
150W
High Pressure Sodium
Bronze
Glass
WL150MH
150W
Metal Halide
Bronze
Glass
WL175MH
175W
Metal Halide
Bronze
Glass
WL250HPS
250W
High Pressure Sodium
Bronze
Glass
WL250MH
250W
Metal Halide
Bronze
Glass
WL400HPS
400W
High Pressure Sodium
Bronze
Glass
WL400MH
400W
Metal Halide
Bronze
Glass
120/208/240/277V
Quad Tap
120/208/240/277V
Quad Tap
120/208/240/277V
Quad Tap
120/208/240/277V
Quad Tap
120/208/240/277V
Quad Tap
120/208/240/277V
Quad Tap
120/208/240/277V
Quad Tap
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
High Intensity Discharge (HID) Lighting
Floodlights
Ideal for: Buildings, Backyards, Highway Signs, Outdoor Advertising Boards, Parks and Sports Fields
• UL and CUL listed for wet locations
• Heavy duty die-cast aluminum powder coating construction
• Corrosion-resistant hardware
Part Number
• High impact-resistant tempered glass
• Lamp holder E-26, UL approved
• Multi-tap ballast: 120/208/240/277 Volts
Wattage
Lamp
Voltage
Finish
Lens
FL035HPS
FL050HPS
FL070HPS
35W
50W
70W
High Pressure Sodium
High Pressure Sodium
High Pressure Sodium
120V
120V
120V
Bronze
Bronze
Bronze
Glass
Glass
Glass
FL050MH
50W
Metal Halide
Bronze
Glass
FL070MH
70W
Metal Halide
Bronze
Glass
FL100HPS
100W
High Pressure Sodium
Bronze
Glass
FL100MH
100W
Metal Halide
Bronze
Glass
FL150HPS
150W
High Pressure Sodium
Bronze
Glass
FL150MH
150W
Metal Halide
Bronze
Glass
FL175MH
175W
Metal Halide
Bronze
Glass
FL250HPS
250W
High Pressure Sodium
Bronze
Glass
FL250MH
250W
Metal Halide
Bronze
Glass
FL400HPS
400W
High Pressure Sodium
Bronze
Glass
FL400MH
400W
Metal Halide
Bronze
Glass
120/208/240/277V
Quad Tap
120/208/240/277V
Quad Tap
120/208/240/277V
Quad Tap
120/208/240/277V
Quad Tap
120/208/240/277V
Quad Tap
120/208/240/277V
Quad Tap
120/208/240/277V
Quad Tap
120/208/240/277V
Quad Tap
120/208/240/277V
Quad Tap
120/208/240/277V
Quad Tap
120/208/240/277V
Quad Tap
FL035HPS
FL050HPS
FL070HPS
FL050MH
FL070MH
FL100MH
FL100HPS
FL150MH
FL175MH
FL150HPS
FL250MH
FL400MH
FL250HPS
FL400HPS
DD175MV
DD150HPS
Dusk-to-Dawn Lights
Ideal for: Perimeter and Security Lighting, Loading Platforms, Barnyards, Parking Lots, Rural Homes, Public
Entrances and OFF-Street Parking
• UL listed for wet locations
• Precision die-cast aluminum housing with natural finish
• UV-stabilized PS Lens
• 24” arm
Part Number
DD150HPS
DD175MV
• Dusk-to-dawn with twist-lock photo control
• Mounting hardware included
• Lamp holder E-39, 4KV and UL approved
• 120 Volt fixture
Wattage
Lamp
Voltage
Lens
Arm
150W
175W
High Pressure Sodium
Mercury Vapor
120V
120V
Polycarbonate
Polycarbonate
24”
24”
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
65
High Intensity Discharge (HID) Lighting
Quartz Floodlights
Ideal for: Building Facades, Signs, Sports Fields and Emergency and Temporary Floodlighting
FL150Q
• UL and CUL listed for wet locations
• Die-cast aluminum construction
• Tempered door glass
• Hinged front door
Part Number
FL300Q
FL500Q
FL150Q
FL300Q
FL500Q
• 1/2” threaded swivel mount
• Dark bronze finish
• 120 Volt fixture
Wattage
Lamp
Voltage
Finish
Lens
150W
300W
500W
Quartz Halogen
Quartz Halogen
Quartz Halogen
120V
120V
120V
Bronze
Bronze
Bronze
Glass
Glass
Glass
Canopy Lights
Ideal for: Parking Areas, Entrances, Walkways, Underpasses, Loading Docks and Recreation Areas
• UL listed for wet locations
• Heavy duty die-cast aluminum powder coating construction
• High impact polycarbonate lens
• Corrosion-resistant hardware
Part Number
Wattage
Lamp
Voltage
Finish
Lens
High Pressure Sodium
120/208/240/277V
Quad Tap
Bronze
Polycarbonate
CP150HPS
CP150HPS
150W
• 1/2” tapped holes available for installing photocell (photocell
optional)
• multi tap ballast: 120/208/240/277 Volts
Wall Fixture with Photocell
Ideal for: Parking Areas, Entrances, Walkways, Underpasses, Loading Docks and Recreation Areas
WL070HPSPC
66
• UL listed for wet locations
• High-impact polycarbonate lens and housing
• Aluminum baseplate with conduit access
• Corrosion-resistant hardware
• 120 Volt installed photocell included
• Multi-tap ballast: 120 Volt fixture
Part Number
Wattage
Lamp
Voltage
Finish
Lens
WL070HPSPC
70W
High Pressure Sodium
120V
Bronze
Polycarbonate
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Helping Maintain the Luxuries of Life
Few things exceed the pleasure of a refreshing dip in the
pool on a hot summer day or a relaxing soak in the hot
tub on a chilly evening. Intermatic helps maintain
these luxuries with a variety of reliable controls,
which combine economy and flexibility in a
single enclosure.
Too often, as technology advances,
controlling that technology becomes
exceedingly complex. Intermatic has
made a commitment to provide its
customers with controls that are as
easy to install as they are to use.
While maintaining its reputation
for reliability, Intermatic
designs innovative pool and
spa controls that are powerful
and intuitive.
Providing simple, focused
controls allows the consumer
to purchase only the features
they need for their application
– saving money and easing
frustration. Intermatic’s
products are flexible and
designed to work together
cohesively in an endless number
of scenarios. Intermatic controls
reduce installation costs and
maintain consistent performance for
aeration, freeze protection, lighting
and pumping year after year.
67
Digital Wireless Controls
PE40000 Series
I-Wave Wireless Pool/Spa Control
Intermatic’s wireless pool and spa controls utilize ground-breaking Z-wave™ technology. While some controls
communicate transmission problems, Intermatic’s wireless devices allow total and uninterrupted
communication between the controller and the equipment.
Intermatic’s modular approach provides for added diversity and convenience. Modules are capable of working
independently or within a system. Portions can be added or replaced without interfering with the original
system, and each system can be designed to incorporate as many or as few features as needed to accomplish
the task at hand – making Intermatic the most value added and cost-effective choice.
All I-Wave Models include wireless transmitter and transceiver, two PE24VA valve actuators, five total circuits
(three timed and two on demand), two-speed control, water temperature display, heater temperature control,
fireman switch, freeze protection and 125 Amp breaker base.
Applications
• Pool/Spa combinations
• Water features
• Fountains
PE950
Specifications
Case — 26.0" (66.3 cm) high x 18.0" (45.9 cm) wide x 5.5" (14.0 cm) deep, 0.048" steel with
electrostatically applied light beige finish.
Knockouts: Two combination 3/4”–1”–1-1/4” and eleven combination 1/2”–3/4” knockouts on the bottom.
Two 3/4”–1” combination and four combination 1/2”–3/4” knockouts on the back. Low voltage
compartment has two combination 1/2”–3/4” knockouts and one 3/4” hole with a shutter bushing installed.
Two combination 3/4”–1” and one combination 1/2–3/4” knockouts. One 1-3/4” x 2-3/4” knockout on the
right side.
Switch Rating: P1353ME – see page 70; P4243ME – see page 71
Model
Mechanisms
Switch
Transformer
Volts 60Hz
Shipping Weight
PE45343RC
PE45343RCT1
PE45343RCT3
PE650
PE950
P1353ME and P4243ME
P1353ME and P4243ME
P1353ME and P4243ME
Wireless Receiver
Wireless Transmitter
5 - SPST
5 - SPST
5 - SPST
–
–
None
100 Watt
300 Watt
–
–
120 or 208-240
120 or 208-240
120 or 208-240
–
–
44.0 lbs.
51.0 lbs
56.0 lbs
5.5 lbs
5.5 lbs
Complete System
PE650
PE45343RC
68
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Salt Chlorine Generators
PE25 & PE40 Series
I-Pure Stand Alone Salt Chlorine Generator
While traditional Salt Chlorine Generators can be difficult to manage and operate, the new I-Pure Salt Chlorine
Generator takes the hassle out of sanitizing pools and spas. The I-Pure system produces more chlorine than
other Salt Chlorine Generators and provides homeowners with easy-to-use, high quality sanitation at a
competitive price.
Designed for pools up to 25,000 gallons or 40,000 gallons, the I-Pure Stand Alone Salt Generator’s
self-adjustable control dial allows users to increase or decrease chlorine production with ease. The simplified
controls of the I-Pure deliver easy pool maintenance.
Applications
• Residential Pools
• Water Features
• Commercial Pools
• Fountains
Specifications
Case — 15.0" (38.3 cm) high x 10.5" (26.8 cm) wide x 4.5" (11.4 cm) deep.
Voltage: 120VAC or 240VAC (See Below)
Shipping Weight: See Chart
Agency Approval: ARL
PE40K240V
Checklist for proper operation:
Salt
3000 to 4000 ppm
Free Chlorine
1 to 3 ppm
PH
7.2 to 7.8
Total Alkalinity
80 to 180 - adjust per calcium hardness level
Stabilizer (Cyanuric Acid) 60 - 80
Nitrates
0 ppm
Metals
0 ppm
Phosphates
0 ppm
Calcium Hardness
Determine level for individual pool surface
Saturation Index
-0.3 to 0.3 (0 is ideal)
Model
PE25K120V
PE25K240V
PE40K120V
PE40K240V
Cell Features
Max Gallons
Volts 60 Hz
Shipping Weight
25,000
25,000
40,000
40,000
120
208-240
120
208-240
22.0 lbs (9.9 kg)
22.0 lbs (9.9 kg)
22.0 lbs (9.9 kg)
22.0 lbs (9.9 kg)
The I-Pure system utilizes plates that are
specially coated to convert regular table salt into
natural chlorine. The system uses the most
advanced self-cleaning technologies, including
reversed polarity, which allows the Cell to stay
cleaner and last longer than other self-cleaning
cells. The clear Cell also allows for easy regular
inspections for calcium build-up.
I-Pure Demo Kits
PEDCHLR - Empty I-Pure shell only
PEDCELL - Empty I-Pure cell only
PE25KCELL
Replacement 25,000 gallon cell only
PE40KCELL
Replacement 40,000 gallon cell only
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
69
Digital Control Mechanisms
P1353ME
Digital Pool/Spa Mechanism
Designed as part of the I-Wave system and for aftermarket and retro-fit applications, the P1353ME has the
ability to program three circuits and snap into almost any Intermatic enclosure. Five pre-programmed modes
of operation include single speed pump or two-speed pump and booster/cleaner pump combinations. In
addition, programmed modes that include auxiliaries can control pumps up to 3HP as well as underwater,
garden and/or fountain lighting. Countdown and Override features allow cycle interruptions when pool/spa
service is required. All timing and protection associated with filter pump/cleaner pump combinations and two
speed pumps has already been integrated into the software.
Applications
• Single Speed Pump Combos
• Two-Speed Pump/Booster Pump Combos
• Pool & Spa Lighting
• Water Feature Applications
• Garden & Fountain Lighting
• Landscape Lighting
Key Features Include
P1353ME
• Memory Back-Up
• Heater Protection (Fireman Switch)
• Three On/Off Events per Day per Circuit
• Wired Remote – 133PE1484A (optional)
• 120V or 240V Input
• LCD Display
• Freeze Protection Probe – 178PA28A (optional)
Mode 1 – (Aux1, Aux2, Aux3)
The time switch is a 3-circuit switch with all three switches controlling auxiliary devices.
Mode 2 – (Pump High, Pump Low, Aux3)
The time switch is a 2-circuit switch with the 1st & 2nd switch controlling a two-speed pump. The 3rd
switch is controlling any auxiliary device. All protection associated with a two speed pump is
preprogrammed into this mode.
Mode 3 – (Pump, Aux2, Cleaner Pump)
The time switch is a 3-circuit switch with the 1st switch controlling a single speed pump, the 2nd switch
controls any auxiliary device, and the 3rd switch operates a booster/cleaner pump. All timing & protection
associated with a filter pump/cleaner pump combination is preprogrammed into this mode.
133PE1484A
Mode 4 – (PumpHigh, PumpLow, Cleaner Pump)
The time switch is a 2-circuit switch with the 1st & 2nd switch controlling a 2-speed pump. The 3rd switch
is controlling a booster/cleaner pump. All protection associated with a 2-speed pump and booster/cleaner
pump combination is preprogrammed into this mode.
Mode 5 – (Pump L1, Pump L2, Aux3)
178PA28A
The time switch is a 2-circuit switch with the 1st & 2nd switch controlling a 240V pump, where both
L1 & L2 are required to be disconnected when the pump is OFF. The 3rd switch is controlling any auxiliary
device.
Specifications
Input Voltage – 120 Volt or 208-240 Volt, 50/60 Hz.
Number of Circuits – Up to three SPST 3HP circuits.
Switch Rating (each circuit) – 20 Amp Resistive, 120/240 VAC, 50/60 Hz; 20 Amp FLA @ 120 VAC, 96
Amp LRA @ 120 VAC, 50/60 Hz; 17 Amp FLA @ 240 VAC, 80 Amp LRA @ 240 VAC, 50/60 Hz; 5 Amp
Tungsten, 120/240 VAC, 50/60 Hz; 5 Amp Ballast, 120/240V VAC, 50/60 Hz
Shipping Weight – 3.0lbs. (1.4 kg.)
Note: The P1353ME will not retro-fit into any enclosure that uses stand off posts to attach the mechanism.
70
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Digital Control Mechanisms
P4243ME
Pump/Valve Actuator Mechanism
Designed as part of the I-Wave system, this electronic control mechanism, especially designed for pool/spa
combinations, will snap into most Intermatic panels and enclosures in use today. Designed as a very versatile,
user-friendly device, it can be combined with a number of different Intermatic controls in order to facilitate a
variety of custom applications. This mechanism can handle two motor loads, up to 3 HP, switch up to
3 valve actuators, the heater thermostats and also allow the user to select pool and spa heater operation.
The control options are numerous. For example, the Pool-to-Spa operation can be activated three different
ways. By a remote installed count down timer, a radio receiver or a simple toggle switch. In the pool mode,
any new or existing timer or manual switch may be used to control the filter pump operation. In the Spa mode,
the filter pump and an additional piece of equipment can be controlled by a wired remote on the spa side
(133PE1484A), by wireless remote, or by the buttons provided on the face of the mechanism.
If combined with the P1353ME Digital Pool/Spa mechanism, the two units can handle all the equipment
variations of a pool/spa combination, including two-speed filter pump, cleaner pump, up to three 24 volt valve
actuators, two stage protected heater, jet pump, blower and lights.
P4243ME
Applications
• Pool/Spa Combinations
• Blower
• Pool & Spa Lighting
• Water Feature
• Filter Pump
• Jets
• Landscape Lighting
Specifications
Input Voltage – 120 Volt or 208-240 Volt, 50/60 Hz.
Switch Rating (each circuit) – 17 Amp resistive 120-240V, 10 Amp Tungsten – 120V, 1.5 HP – 120V, 3 HP
– 240V, 60Hz
Number of Circuits – Up to two DPST 3HP circuits
Shipping Weight – 5 lbs (2.2 kg)
133PE1484A
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
71
Digital Controls
PE100 Series
Mini PE Series Digital Pool or Spa Controls
Intermatic’s Mini-PE Series Digital Controls couple the standard features of our compact T100 Series
mechanical time switches with the convenience of digital automation. One of Intermatic’s latest innovations,
the P1353ME allows the ability to program up to three circuits. Beyond single and two-speed pump/booster
pump applications, auxiliary modes can control pumps up to 3HP as well as underwater, garden and/or
fountain lighting.
Countdown and override features allow cycle interruptions when pool/spa service is required. All timing and
protection associated with filter pump/booster pump combos and two-speed pumps has already been
integrated into the digital software. The Mini-PE Series is available in both metal and plastic enclosures and
with a wired remote command, freeze probe or both. See chart below for details.
PE153
Intermatic makes it simple to convert your Mini-PE Series Digital Control into a Wireless Control System.
Simply install a Panel Mounted Transceiver (RC650) and Hand-Held Transceiver (PE950) to any Mini-PE
Series control, which allows the system to display the status of each of the three circuits as well as pool or spa
water temperature, pool or spa thermostat set point, heating status and overall communication status.
Applications
• Single Speed Pump/Booster Pump Combos
• Water Feature Applications
• Pool & Spa Lighting
• Two-Speed Pump/Booster Pump Combos
• Garden & Fountain Applications
• Landscape Lighting
Specifications
PE153W
PE153F
Case – NEMA 3R rated for indoor-outdoor installation. 9-3/8" (23.8 cm) high, 5-1/2" (14.0 cm) wide,
3-5/8" (9.2 cm) deep in beige finish. “P” suffix models are same dimensions, except made from outdoor
grade plastic.
Knockouts – Combination 1/2" – 3/4" nominal knockouts, one on back and each side of case and two
on bottom.
Switch Rating (each circuit) – 20 Amp Resistive, 120/240 VAC, 50/60 Hz; 20 Amp FLA @ 120 VAC, 96
Amp LRA @ 120 VAC, 50/60 Hz; 17 Amp FLA @ 240 VAC, 80 Amp LRA @ 240 VAC, 50/60 Hz; 5 Amp
Tungsten, 120/240 VAC, 50/60 Hz; 5 Amp Ballast, 120/240V VAC, 50/60 Hz
Shipping Weight – 3.7 lbs (1.7 kg)
Agency Approval – CSA/C-US
Model #
Description
Switch
Clock Supply
PE153
PE153W
Digital Time Clock in Metal Enclosure
Digital Time Clock in Metal Enclosure
with 100' Wired Remote Command
Digital Time Clock in Metal Enclosure
with Freeze Protection Probe
Digital Time Clock in Metal Enclosure
with 100' Wired Remote Command & Freeze Protection Probe
Digital Time Clock in Plastic Enclosure
Digital Time Clock in Plastic Enclosure
with 100' Wired Remote Command
Digital Time Clock in Plastic Enclosure
with Freeze Protection Probe
Digital Time Clock in Plastic Enclosure
with 100' Wired Remote Command & Freeze Protection Probe
3 - SPST
3 - SPST
120 or 240V
120 or 240V
3 - SPST
120 or 240V
3 - SPST
120 or 240V
3 - SPST
3 - SPST
120 or 240V
120 or 240V
3 - SPST
120 or 240V
3 - SPST
120 or 240V
PE153F
PE153WF
PE153P
PE153PW
PE153PF
PE153PWF
NOTE: See page 68 for PE650 and PE950 specifications and page 70 for P1353ME specifications
PE153WF
72
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Digital Controls
PE Series Digital Controls
For pool, spa or water feature applications, the PE Series Digital Controls includes one P1353ME mechanism
that controls a total of three timed circuits, including single-speed or two-speed filter pumps, cleaner/booster
pumps, pool lights, spa lights and landscape lights.
Intermatic makes it simple to convert your PE Series Digital Control into a Wireless Control System. Simply
install a Panel Mounted Transceiver (RC650) and a Hand-Held Transceiver (PE950).
Applications
• Single Speed Pump/Booster Pump Combos
• Water Feature Applications
• Two-Speed Pump/Booster Pump Combos
• Garden & Fountain Applications
• Pool & Spa Lighting
• Landscape Lighting
PE25300
Case – 16-1/2" (41.9 cm) high x 10-7/8" (27.6 cm) wide x 4-1/4" (10.8 cm) deep, 0.048" steel with
electrostatically applied light beige finish.
Knockouts – One 1.09 diameter through hole, six combination 1/2"-3/4" knockouts, and three combination
3/4"-1" knockouts on the bottom. Two combination 1/2"-3/4" on the left side and one combination 3/4"-1" on
the back. One knockout 1-3/4" x 2-3/4" on the right side for mounting switches or GFCI.
Panel Rating – 60 Amp 120/240 V.A.C or 120/208 VAC single phase
Switch Rating – P1353ME - See page 70
Agency Approval – CSA/C-US
PE25300
PE35300
Case – 22" (55.9 cm) high x 14-3/4" (37.5 cm) wide x 4-1/4" (10.8 cm) deep, 0.048" steel with light beige
finish.
Knockouts – One 1.09 diameter through hole, six combination 1/2"-3/4" knockouts, 2 combination 3/4", 1",
1-1/4" knockouts, four 1/2" knockouts on the bottom. Two combination 1/2"-3/4" knockouts on the left side
and four combination 1/2"-3/4" knockouts, two combination 3/4"-1" on the back. One knockout 1-3/4" x 23/4" on the right side for mounting switches or GFCI.
Panel Rating – 80 Amp 120/240 VAC or 120/208 VAC single phase
Switch Rating – P1353ME - See page 70
Agency Approval – CSA/C-US
Model #
Description/Mechanism
Switch
Clock Supply Volts 60 Hz
Shipping Weight
PE25300
PE35300
P1353ME
P1353ME
3–SPST
3-SPST
120 or 240
120 or 240
14.0 lbs (6.3 kg)
19.0 lbs (8.6 kg)
PE35300
PE1500RC Series
Mini-Wave Wireless Pool/Spa Control Panels
For pool/spa combinations or pool/water feature combinations, the PE1541RC controls four circuits, two
PE24VA valve actuators, Wireless Panel Mounted Transceiver (PE650) and Hand-Held Transceiver (PE950),
which allows the system to display the status of each of the four on-demand circuits, pool and spa water
temperature, pool and spa thermostat set point, heating status and overall communication status. PE1501RC
does not include actuators and is designed for pool or spa applications.
PE1500RC
Panel Rating – 100 Amp 120/240 VAC or 120/208 VAC single phase
Switch Rating – 17A Resistive, 120/240 VAC., 50/60 Hz; 1.5 HP @ 120 VAC., 50/60 Hz; 3.0 HP @ 240
VAC., 50/60 Hz; 10 Amp Tungsten, 120/240 VAC, 50/60 Hz
Shipping Weight – 24.3 lbs. (10.9 kg)
Agency Approval – CSA/C-US
Model #
Description/Mechanism
PE1541RC
PE1501RC
PB313E
PB313E
Circuits
Actuators
Switch
Clock Supply Volts 60 Hz
4
4
2
None
4–SPST
4-SPST
120 or 240
120 or 240
PE1541RC
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
73
Mechanical Controls
T10000R Series
Pool & Spa Control Centers
The T10000R Series Control Centers feature an all-weather enclosure and contain one or two heavy duty timer
mechanisms. In addition, they have provision to install switches or GFCI receptacle on the side and additional
switches inside. The enclosure accepts any combinations of P1353ME or P4243ME or T100M or RC2000M
or PF1000M Series mechanisms.
Applications
T10000R
• Filter Pumps-Booster Pump Combinations
• Filter Pump-Light Controls
• Pool-Spa Combinations
• Yard Lighting
• Signs
Specifications
Case – 12" (30.5 cm) H x 12" (30.5 cm) W x 4-1/4" (10.8 cm) D, 0.048" steel with electrostatically applied
light beige finish.
Knockouts – Five combination 1/2"-3/4" and two combination 3/4"-1" knockouts on the bottom. One
combination 1/2"-3/4" on the left side and one combination 3/4"-1" on the back.
One knockout 1-3/4" x 2-3/4" on the right side for mounting switches or GFCI.
Center Rating – 92 Amp per leg, 168 Amp Max. 120-240 VAC or 120-208 VAC single phase - 60 Hz
Time Switch Rating – 30 Amp Resistive Inductive, Tungsten or 1000 VA pilot duty each pole 120/208/240
VAC; 2 HP (24 FLA) - 120 VAC; 5 HP (28 FLA) - 240 VAC
Shipping Weight – See Table.
Agency Approval – CSA/C-US
T10004R
Model #
Description/Mechanism
Switch
T10000R
T10101R
T10004R
T10404R
T10604R*
T12404R**
Enclosure Only
Two T101M
One T104M
Two T104M
T106M & T104M
T104M201 & T104M
None
SPST – SPST
NA – DPST
DPST – DPST
SPDT – DPST
DPST –DPST
Clock Supply Volts 60 Hz
NA / NA
120 /120
NA / 240
240 / 240
240 / 240
240 / 240
Shipping Weight
9.3 lbs (4.2 kg)
11.0 lbs (5.0 kg)
10.5 lbs (4.7 kg)
11.0 lbs (5.0 kg)
11.0 lbs (5.0 kg)
11.0 lbs (5.0 kg)
* For 2 Speed Pump Applications.
** The heater protection switch (fireman switch) is closed when the time switch contacts are open to allow remote operation of
the heater. A flow or pressure switch therefore must always be part of the heater control circuit.
For additional trippers ( 1 “ON” 1 “OFF” per pack), order No. 156T1978A.
For additional “OFF” trippers (25 “OFF” per pack), order No. PA115.
For Stand offs for décor knockouts (4 stand-offs per pack), order No. 21T156A.
T10404R
74
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Mechanical Controls
T20000R Series
60 Amp Pool/Spa Control Panels
The T20000R Series Control Panels feature an all-weather enclosure and contain a 4 circuit breaker base, an
equipment grounding bar and a mechanical time switch mechanism. The circuit breaker base accepts
interchangeable type breakers made by a number of different manufacturers. In addition, the enclosure
has provision for installing additional switches or GFCI receptacles on the side and inside.
Applications
• Filter Pumps
• Signs
• Lights
• Air Conditioners
• Ventilating Systems
• Heaters
T21000R
Specifications
Case – 16-3/4" (42.6 cm) H x 8-7/8" (22.5 cm) W x 4-3/8" (11.1 cm) D. 0.048" steel with electrostatically
applied light beige finish.
Knockouts – Five combination 1/2"-3/4" and three 3/4" - 1" on the bottom, one combination 1/2"-3/4" on the
left side, one 3/4"-1" on the back and one combination 1-3/4" x 2-3/4" knockout on the right side for
mounting switches or GFCI
Panel Rating – 60 Amp 120/240 VAC or 120/208 VAC; Single Phase-60 Hz
Time Switch Rating – 30 Amp Resistive Inductive, Tungsten or 1000 VA pilot duty each pole 120/208/240
VAC; 2 HP (24 FLA) - 120 VAC; 5 HP (28 FLA) - 240 VAC
Shipping Weight – See table.
Agency Approval – CSA/C-US
Model #
Description/Mechanism
Switch
T21000R
T21001R
T21004R
T20004R*
Enclosure only
T101M
T104M
T104M
None
SPST
DPST
DPST
* T20004R has a limited availability, T21004R is the replacement model.
For additional trippers ( 1 “ON” 1 “OFF” per pack ), order No. 156T1978A
For additional “OFF” trippers (25 “OFF” per pack), order No. PA115
For Stand offs for décor knockouts (4 stand-offs per pack), order No. 21T156A
Clock Supply Volts 60 Hz
NA
120
240
240
Shipping Weight
11.2 lbs (5.0 kg)
14.0 lbs (6.3 kg)
14.0 lbs (6.3 kg)
14.0 lbs (6.3 kg)
T21004R
T20004R
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
75
Mechanical Controls
T30000R Series
100 Amp Pool/Spa Control Panels
The T30000R Series Control Panels reduce installation costs and provide all of the electrical requirements for
any pool and/or spa installation. They offer an all-in-one electrical control center which can be custom wired
for a wide variety of requirements, and eliminate the need for additional junction boxes and service panels. The
enclosure accepts any combinations of P1353ME or P4243ME or T100M or RC2000M or PF1000M Series
mechanisms
Applications
T30000R5
• Filter Pumps
• Security Systems
• Booster Pumps
• Fountains
• Heating Systems
• Sprinkler Systems
• Lights
• Valve Actuators
• Cleaning Systems
• Yard Lights
Specifications
Case – 16-1/2" (41.9 cm) H x 10-7/8" (27.6 cm) W x 4-1/4" (10.8 cm) D, 0.048" steel with electrostatically
applied beige finish
Knockouts – Two 1/2", three combination 1/2"-3/4", and two combination 3/4"-1" knockouts on the bottom.
Four 1/2", three combination 1/2"-3/4" on the back. One combination 3/4"-1" on the left side. One 1-3/4" x 23/4" knockout on the right side for mounting switches and GFCI.
Panel Rating – 100 Amp., 120-240 VAC or 120-208 VAC single phase - 60Hz.
Timer Switch Rating – 30 Amp Resistive Inductive, Tungsten or 1000 VA pilot duty each pole 120/208/240
VAC; 2 HP (24 FLA) - 120 VAC; 5 HP (28 FLA) - 240 VAC
Shipping Weight – See table.
Agency Approval – CSA/C-US
T30004R
Model #
Description/Mechanism
Switch
T30000R5
T30004R
T30401R
T30404R
T30604R
T32404R
Enclosure Only
One T104M
T104M & T101M
Two T104M
T106M & T104M
T104M201 & T104M
None
None / SPST
DPST / SPST
DPST / DPST
SPDT / DPST
DPST / DPST
Clock Supply Volts 60 Hz
NA / NA
NA / 240
240 / 120
240 / 240
240 / 240
240 / 240
Shipping Weight
18.6 lbs (8.4 kg)
18.6 lbs (8.4 kg)
18.6 lbs (8.4 kg)
18.6 lbs (8.4 kg)
18.6 lbs (8.4 kg)
18.6 lbs (8.4 kg)
* The heater protection switch (fireman switch) is closed when the time switch contacts are open to allow remote operation of
the heater. A flow or pressure switch therefore must always be part of the heater control circuit.
For additional trippers ( 1 “ON” 1 “OFF” per pack), order No. 156T1978A.
For additional “OFF” trippers (25 “OFF” per pack), order No. PA115.
For Stand offs for décor knockouts (4 stand-offs per pack), order No. 21T156A.
T32404R
76
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Quality Pool & Spa Controls
T40000R Series
125 Amp Pool/Spa Control Panels
The T40000R Series Control Panels reduce installation costs and provide all of the electrical requirements for
any pool and/or spa installation. They offer an all-in one electrical control center which can be custom wired
for a wide variety of requirements, and eliminate the need for additional junction boxes and service panels. The
enclosure accepts any combinations of P1353ME or P4243ME or T100M or RC2000M or PF1000M Series
mechanisms.
T40000R
Applications
• Filter Pumps
• Security Systems
• Booster Pumps
• Fountains
• Heating Systems
• Sprinkler Systems
• Lights
• Yard Lights
• Cleaning Systems
Specifications
Case – 20-3/4" (52.7 cm) high x 12-3/4" (32.4 cm) wide x 4-1/4" (10.8 cm) deep, 0.048" steel with electrostatically applied light beige finish
Knockouts – Seven combination 1/2"-3/4" and three combination 3/4"-1" knockouts on the bottom.
Five combination 1/2"-3/4" on the left side. One 1-3/4" x 2-3/4" knockout on the right side for mounting
switches and GFCI
Panel Rating – 1
Timer Switch Rating – 30 Amp Resistive Inductive, Tungsten or 1000 VA pilot duty each pole 120/208/240
VAC; 2 HP (24 FLA) - 120 VAC; 5 HP (28 FLA) - 240 VAC
Shipping Weight – See table.
Agency Approval – CSA/C-US
Model #
Description/Mechanism
Switch
T40000R
T40004R
T40404R
Enclosure Only
One T104M
Two T104M
None
DPST
DPST
Clock Supply Volts 60 Hz
NA
NA / 240
240 / 240
Shipping Weight
T40004R
T40404R
16.0 lbs (7.2 kg)
20.5 lbs (9.2 kg)
21.2 lbs (9.5 kg)
For additional trippers ( 1 “ON” 1 “OFF” per pack ), order No. 156T1978A.
For additional “OFF” trippers (25 “OFF” per pack), order NO. PA115.
For additional stand-offs for décor knockouts (4 stand-offs per pack), order No. 21T156A.
T40000R Series
100 Amp Specialty Control Panels
T40000R4
These specialty Control Panels are the same as the T40000R Series, except they have been designed for
specialty applications. Models include a factory installed GFCI, or stainless steel panel for high corrosive
environments or an inside wiring compartment for two devices. These enclosures accept any combinations of
T100M, P1353ME, P4243ME or T100M or RC2000M or PF1000M Series mechanisms.
Applications Specifications
Same as above.
Case, Knockouts, Timer Switch Rating & Agency Approval – Same as above
Panel Rating – 115 Amp. 120-240 VAC or 120-208 VAC single phase - 60 Hz.
Shipping Weight – See table.
Model #
Description/Mechanism
Switch
T40000R4*
T40004RSS**
T40004R5
T40404R5
Inside Compartment
One T104M
One T104M & GFCI Installed
Two T104M & GFCI Installed
None / None
None / DPST
None / DPST
DPST / DPST
T40004RSS
Clock Supply Volts 60 Hz
Shipping Weight
NA / NA
NA / 240
NA / 240
240 / 240
19.4 lbs (8.7 kg)
20.5 lbs (9.2 kg)
21.6 lbs (9.7 kg)
24.6 lbs (11.0 kg)
* Enclosure only with inside wiring compartment for twist-lock receptacle and GFCI.
** Stainless Steel Enclosure.
For additional trippers ( 1 “ON” 1 “OFF” per pack ), order No. 156T1978A.
For additional “OFF” trippers (25 “OFF” per pack), order NO. PA115.
For additional stand-offs for décor knockouts (4 stand-offs per pack), order No. 21T156A.
T40004R5
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
77
Safety Transformers
T10000RT, T40000RT & PE45343RCT Series
Pool Panels with Transformer
These Panels with Transformer offer an all-in-one, easy to wire and extremely cost effective electrical control
center for any pool or spa installation. Inside the enclosure are the time switch, the transformer and other
components needed for the completion of this installation. The T40000RT Series panels will accept additional
Intermatic mechanisms and/or components.
The PE45343RCT Series includes all the features of the PE Series Digital Controls plus two PE24VA valve
actuators, Wireless Panel Mounted Transceiver (PE950), which allows the system to display the status of each
of the five circuits (3 timed and 2 on demand), pool and spa water temperature, pool and spa thermostat set
point, heating status and overall communication status.
T10004RT1
Applications
• Filter Pumps
• Low Voltage Outdoor Lighting
• Blowers
• Fountains
• Low Voltage Pool/Spa Lighting
Specifications
T10000RT Series
Case – 12" (30.5 cm) H x 12" (30.5 cm) W x 4-1/4" (10.8 cm) D, 0.048" steel with electrostatically applied
light beige finish
Knockouts – Five combination 1/2"-3/4" and two combination 3/4"-1" knockouts on the bottom.
One combination 1/2"-3/4" on the left side and one combination 3/4"-1" on the back. One knockout
1-3/4" x 2-3/4" on the right side for mounting switches or GFCI
Center Rating – 92 Amp per leg, 168 Amp Max. 120-240 VAC or 120-208 VAC single phase - 60 Hz.
T40004RT3
T40000RT Series
Case – 20-3/4" (52.7 cm) high x 12-3/4" (32.4 cm) wide x 4-1/4" (10.8 cm) deep, 0.048" steel with
electrostatically applied light beige finish.
Knockouts – Seven combination 1/2"-3/4" and three combination 3/4"-1" knockouts on the bottom. Five
combination 1/2"-3/4" on the left side. One 1-3/4" x 2-3/4" knockout on the right side for mounting switches
and GFCI.
Panel Rating – T40000RT Series - 100 Amp 120-240 VAC or 120-208 VAC single phase - 60 HZ
Timer Switch Rating – 30 Amp Resistive Inductive, Tungsten or 1000 VA pilot duty each pole
120/208/240 VAC; 2 HP (24 FLA) - 120 VAC; 5 HP (28 FLA) - 240 VAC
PE45343RCT Series
Case – 12" (30.5 cm) H x 12" (30.5 cm) W x 4-1/4" (10.8 cm) D, 0.048" steel with electrostatically applied
light beige finish
Knockouts – Five combination 1/2"-3/4" and two combination 3/4"-1" knockouts on the bottom.
One combination 1/2"-3/4" on the left side and one combination 3/4"-1" on the back. One knockout
1-3/4" x 2-3/4" on the right side for mounting switches or GFCI
Panel Rating – T40000RT Series - 100 Amp 120-240 VAC or 120-208 VAC single phase - 60 HZ
Agency Approval – CSA/C-US
Model #
T10004RT1
T10004RT3
T40003RT3
T40004RT1
T40004RT3
PE45343RCT1
PE45343RCT3
PE45343RCT3
78
Transformer
Input 60 Hz
Output
Mechanism
Shipping Weight
100 Watt
300 Watt
300 Watt
100 Watt
300 Watt
100 Watt
300 Watt
120V, 1 Amp
120V, 3 Amp
120V, 3 Amp
120V, 1 Amp
120V, 3 Amp
120V, 1 Amp
120V, 3 Amp
12V, 13V,
12V, 13V, 14V
12V, 13V, 14V
12V, 13V,
12V, 13V, 14V
12V, 13V
12V, 13V, 14V
T104M
T104M
T103M
T104M
T104M
P1353ME & P4243ME
P1353ME & P4243ME
14.0 lbs (6.3 kg)
20.0 lbs (9.0 kg)
32.0 lbs (14.4 kg)
26.0 lbs (11.7 kg)
32.0 lbs (14.4 kg)
56.0 lbs (25.2 kg)
61.0 lbs (27.5 kg)
For additional trippers ( 1 “ON” 1 “OFF” per pack ), order No. 156T1978A.
For additional “OFF” trippers (25 “OFF” per pack), order No. PA115.
For stand-offs for décor knockouts (4 stand-offs per pack), order No. 21T156A.Note: See Page 29 for a detailed list of T100M replacement
mechanisms and page 16 for PE650 and PE950 specifications
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Safety Transformers
PX100, PX300 & PX600 SeriesSafety Transformers
These Safety Transformers are specifically designed to supply 12 volts to pool/spa lights, submersible fixtures
and outdoor garden lights. A grounded shield between the primary and secondary windings assures safe
operation and the built-in circuit protection will disconnect power to the transformer in case of defect or
overload.
Applications
• Pool Lights
• Spa Lights
• Garden Lights
• Fountain Lights
PX100
Specifications - PX100/S, PX300/S
Enclosure – 7.25" (19.4 cm) H x 5.25" (13.3 cm) W x 4.5" (11.4 cm) D. Stainless steel or steel with
electrostatically applied light beige finish. Mounting brackets top and bottom.
Knockouts – Total of ten combination 1/2”-3/4” knockouts, (2) right side, (2) left side, (2) back, (4) bottom.
Electrical Rating – See table.
Shipping Weight – See table.
PX100S
Specifications – PX600/S
Enclosure – 10" (25.4 cm) high x 10" (25.4 cm) wide x 5" (12.7 cm) deep. Stainless steel or steel with
electrostatically applied light beige finish. Mounting brackets top and bottom.
Knockouts – Two combination 1/2"-3/4", and 4 combination 3/4"-1" knockouts on the bottom. Total of six
combination 1/2"-3/4" knockouts, (2) right side, (2) left side, (2) back.
Electrical Rating – See table.
Shipping Weight – See table.
Model #
Description
Input
Output
Shipping Weight
PX100
PX100S
PX300
PX300S
PX600
PX600S
100 Watt Beige Steel Enclosure
100 Watt Stainless Steel Enclosure
300 Watt Beige Steel Enclosure
300 Watt Stainless Steel Enclosure
600 Watt Beige Steel Enclosure
600 Watt Stainless Steel Enclosure
120V, 1AMP
120V, 1AMP
120V, 3AMP
120V, 3AMP
120V, 6AMP
120V, 6AMP
12 or 13V
12 or 13V
12,13 or 14V
12,13 or 14V
12,13 or 14V
12,13 or 14V
7.0 lbs (3.2 kg)
7.0 lbs (3.2 kg)
13.0 lbs (5.9 kg)
13.0 lbs (5.9 kg)
26.0 lbs (11.7 kg)
26.0 lbs (11.7 kg)
PX300
PX300S
PX600
PX600S
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
79
Freeze Protection Controls
PF1100 Series
Single Circuit Freeze Protection Controls
These Freeze Protection Controls are designed to protect the pool and spa equipment and plumbing against
freeze damage. They turn the pump and the heater ON vwhen the outdoor temperature drops below the temperature set by the user-adjustable thermostat.
Models without timer connect to a timing or switching device and together, they control operation of the
equipment as well as protect it against freeze damage. Models with timer provide both automation and
protection for the equipment.
PF1102M
APPLICATIONS
• Filter Pumps
• Waterfalls
• Filter Pump/Booster Pump Combinations
• Water Features
SPECIFICATIONS
PF1102
CASE - 0.034 inch drawn steel, electrostatically coated, beige color. Hasp, with hole for lock, holds
permanently attached side-hinged door closed. 9-3/8" (23.8 cm) high x 5-1/4" (14.0 cm) wide x 3-5/8"
(9.2 cm) deep.
KNOCKOUTS - 1/2" - 3/4" combination knockouts, one back, one on each side, two bottom.
THERMOSTAT RANGE - 45°F - 32°F with 5 degrees differential.
ELECTRICAL RATING - See table
SHIPPING WEIGHT - See table.
AGENCY APPROVAL - CSA/C-US
Model #
Description
Input
PF1102
PF1102M
PF1102T
PF1102MT
PF1103
PF1103M
PF1103T
PF1103MT
Thermostat only. For 240V installation.
Same as above, mechanism only.
Timer with thermostat. For 240V installation.
Same as above, mechanism only.
Thermostat only. For 120/240V installation.
Same as above, mechanism only.
Timer with thermostat. For 120/240V installation
Same as above, mechanism only.
240V
240V
240V
240V
120/240V*
120/240V*
120/240V*
120/240V*
Rating H.P.
3
3
3
3
1.5/3
1.5/3
1.5/3
1.5/3
Shipping Weight
3.7 lbs (1.7 kg)
2.0 lbs (0.9 kg)
4.5 lbs (2.0 kg)
2.5 lbs (1.1 kg)
3.7 lbs (1.7 kg)
2.0 lbs (0.9 kg)
4.5 lbs (2.0 kg)
2.5 lbs (1.1 kg)
* Neutral must be installed.
PF1103MT
PF1103T
80
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Freeze Protection Controls
PF1100 & PF1200 Series
Multi Circuit Freeze Protection Control Centers & Panels
These heavy-duty Freeze Protection Controls are designed specifically for pools requiring one or two time
switches and protect the pool and spa equipment and plumbing against freeze damage. They turn the pump
and the heater ON when the outdoor temperature drops below the temperature set by the user-adjustable
thermostat. In addition, they have a provision to install switches inside or GFCI receptacle on the side of
enclosure.
Applications
• Filter Pumps
• Combinations
• Filter Pump-Booster Pump
• Pool-Spa Combinations
• Fountains
PF1112T
Specifications
PF1112T, PF1202T
Case – 12" (30.5 cm) H x 12" (30.5 cm) W x 4-1/4" (10.8 cm) D, 0.048" steel with electrostatically applied
light beige finish.
Knockouts – Five combination 1/2"-3/4" and two combination 3/4"-1" knockouts on the bottom. One combination 1/2"-3/4" on the left side and one combination 3/4"-1" on the back. One knockout 1-3/4" x 2-3/4" on
the right side for mounting switches or GFCI
Center Rating – 92 Amp per leg, 168 Amp Max. 120-240 VAC or 120-240VAC single phase - 60 Hz.
Electrical Rating – See table.
Thermostat Range – 44°F - 32°F with 5 degrees differential.
Shipping Weight – See table.
Agency Approval – CSA/C-US
PF1222TB
Case – 16-1/2" (41.9 cm) H x 10-7/8" (27.6 cm) W x 4-1/4" (10.8 cm) D, 0.048" steel with electrostatically
applied beige finish.
Knockouts – Two 1/2", three combination 1/2"-3/4", and two combination 3/4"-1" knockouts on the bottom.
Four 1/2", three combination 1/2"-3/4" on the back. One combination 3/4"-1" on the left side. One 1-3/4" x 23/4" knockout on the right side for mounting switches and GFCI.
Panel Rating – 100 Amp max., 120-240 VAC or 120-208 VAC single phase - 60 Hz.
Electrical Rating – See table.
Thermostat Range – 44°F - 32°F with 5 degrees differential.
Shipping Weight – See table.
Agency Approval – CSA/C-US
Model #
Description
PF1112T
PF1202T
PF1222TB
For pools requiring one time switch
For pools with cleaner, requiring two time switches
Same as a PF1202T with 4/8 breaker base and heater protection
Electrical Input
240V
240V
240V
PF1202T
Rating HP Shipping Weight
3
3
3
8.0 lbs (3.6 kg)
10.0 lbs (4.5 kg)
17.0 lbs (7.7 kg)
For additional trippers ( 1 “ON” 1 “OFF” per pack ), order No. 156T1978A.
For additional “OFF” trippers (25 “OFF” per pack), order NO. PA115.
For additional stand-offs for décor knockouts (4 stand-offs per pack), order No. 21T156A.
PF1222TB
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
81
Air Operated Controls
Air Operated Pool/Spa & Pool-to-Spa Controls
This line of Air Operated Controls is specially designed to control pool/spa combinations economically and
reliably for up to 100 ft. away from the equipment. Everything needed to control the filter pump, valves, heater
thermostat, booster pump, blower or lights is included in a single package and can be installed in less than
two hours. A number of accessories are available to enhance the control capacity of these units. Comes
complete with two PE24VA 24-Volt valve actuators.
Applications
• Pool/Spa Combinations
• Water Features
Specifications
RC2403RT
RC2163E
Case – 0.048" steel with electrostatically applied light beige finish. See table for nominal dimensions.
Maximum Range – 100 ft. (The actual distance between the control and air button depends on the amount
of displaced air, the inside diameter of the air hose and other factors beyond the control of the
manufacturer.)
Timer – 24 Hour Electronic.
Specifications/Features
RC2163E
RC2163FE
RC2263E
RC2403RT
Voltage
Remote Command
Filter Pump Timer Controlled in Pool Mode
Single Speed Only (HP)
Single or Two Speed (HP)
Heater Control (Single or Two Stage)
Number of Valve Actuator Connections
Heater Protection (Optional)
Blower
Independent Circuit (DPST 30A, 3HP-240V)
Standard Enclosure (In)
Number of Breaker Space
Shipping Weight (lbs)
Reference Picture
120/240
1-Air
Y
3 HP
NA
Y
3
Y
NO
NO
12.9 x 10.9 x 4.3
NA
20.0 (9.0 kg)
RC2163E
120/240
Any Switch*
Y
3 HP
NA
Y
3
Y
NO
NO
12.9 x 10.9 x 4.3
NA
20.0 (9.0 kg)
RC2163E
120/240
1-Air
Y
NA
2 HP
Y
3
NO
Y
NO
12.9 x 10.9 x 4.3
NA
23.7 (10.7 kg)
RC2163E
120/240
2-Air
Y
NA
2 HP
NO
0
NO
Y
Y
12.9 x 10.9 x 4.3
NA
19.0 (8.6 kg)
RC2163E
*Can use spring wound timer, toggle switch or remote control with transmitter to operate equipment
Specifications/Features
RC2163BE
RC2163BFE
RC2263BE
Voltage
Remote Command
Filter Pump Timer Controlled in Pool Mode
Single Speed Only (HP)
Single or Two Speed (HP)
Heater Control (Single or Two Stage)
Number of Valve Actuator Connections
Heater Protection (Optional)
Blower
Independent Circuit (DPST 30A, 3HP-240V)
Standard Enclosure (In)
Number of Breaker Space
Shipping Weight (lbs)
Reference Picture
120/240
1-Air
Y
3 HP
NA
Y
3
Y
NO
NO
16.8 x 10.9 x 4.3
8/16
24.3 (10.9 kg)
RC2263BE
120/240
Any Switch*
Y
3 HP
NA
Y
3
Y
NO
NO
16.8 x 10.9 x 4.3
8/16
24.3 (10.9 kg)
RC2263BE
120/240
1-Air
Y
NA
2 HP
Y
3
NO
Y
NO
16.8 x 10.9 x 4.3
8/16
28.0 (12.6 kg)
RC2263BE
RC2263BE
82
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Electronic Time Switches
P1000 & P7000 Series
Electronic Time Switches and Mechanisms
This line of electronic time switches in safety enclosures are specially suited for applications where a need to
turn equipment up to 8 ON and OFF cycles daily, and where the automatic operation of the equipment requires
occasional override by someone other than a qualified service professional. Electronic technology allows upto-the-minute programming accuracy. The unique “door within the door” provides safe access to the timer
control buttons, but prevents entry into the wiring compartment. Light indicator illuminates when timer is in
ON position. An override feature is provided to allow pool service without interruption of ON-OFF settings.
Select feature allows timer to be continuously ON, OFF or in Auto mode. The addition of a radio receiver
(Model P1203FR) provides a 2nd circuit for any other load (light, blower etc.) requiring control from a remote
location. Typical application for the clock circuit would be the pool pump, and a pool light for the radio circuit.
In case of power failure, a replaceable battery preserves programming for up to three years.
P1102ME
Applications
• Filter pumps
• Pool/Spa lights
• Water Features
• Fountains
Specifications
Case – All plastic NEMA 3R rated for indoor-outdoor installation. 9-3/8" (23.9 cm) H, 5-1/2" (14.0 cm) W,
3-5/8" (9.2 cm) D in beige finish.
Knockouts – Combination 1/2" - 3/4" nominal knockouts, (1) on back and each side of case, and (2) on
bottom.
Rating – P1102FE - 3.0 HP @ 240V, 30 Amp resistive; P1203FR - 1.5 HP @ 120V, 3.0 HP @ 240V, 30 Amp
resistive; Radio Circuit - 15 Amp resistive, 10 Amp Tungsten, 1 HP motor load - 120 VAC
Shipping Weight - 3.75 lbs (1.7 kg)
Agency Approval – CSA/C-US
P1102FE
Model
Number
Description
Switch
P1102ME
P1103ME
24-Hour Electronic Mechanism Only
24-Hour Electronic Mechanism Only
One DPST
One DPST
P7101ME
P7102ME
P7103ME
7-Day Electronic Mechanism Only
7-Day Electronic Mechanism Only
7-Day Electronic Mechanism Only
One DPST
One DPST
One DPST
P1102FE
P1103FE
24-Hour Electronic Time Switch
24-Hour Electronic Time Switch
One DPST
One DPST
P1203FR
24-Hour Electronic Time Switch
Radio Receiver Module
One DPST
One SPST
Supply
Voltage 50/60 Hz
240V only clock & load
120V for clock
120V or 240V only clock & load
120V only clock & load
240V only clock & load
120V for clock
120V or 240V only clock & load
240V only clock & load
120V for clock
120V or 240V only clock & load
3.0 HP - 208-240V only clock & load
120V only receiver & load
P1203FR
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
83
Radio Remote Controls
RC600 & RC900
Outdoor Radio Remote Controls
These Modular Radio Receivers are one half of a two part remote control system. They operate as ordinary
ON/OFF switches but they also respond to the signals of a hand held transmitter — the other half of the
system. The modules are designed for indoor or outdoor use, and can handle a variety of switching
applications, typical around the house or farm. By the push of a button on the face of the transmitter, the user
is able to turn ON-OFF the connected load (lights, pump, etc.) from any remote location, inside or outside of
the house, safely and conveniently. In addition, a single transmitter can operate up to three receivers and is
able to “teach” each module a different code (Transmitter model RC939 sold separately).
Applications
RC613R
• Pool/Spa Pumps, Lights and Heaters
• Fountain Pumps
• Outdoor Lighting
• Motorized Valves
• Air Blowers
• Signs
• Motorized Gates
Specifications
Enclosure – Beige outdoor grade plastic.
Maximum Range – 100 ft. See transmitter model RC939 for details.
Model # Description
RC613
Electrical Rating
Receiver with ON/OFF Button
15 Amp Resistive, 10 Amp (1200 W)
Tungsten, 1 HP, Motor Load - 120 V
RC613L RC613 with (3) 36" Long Leads Same as RC613
RC613R Heavy Duty Receiver Module
30 Amp Resistive, 120/240 V
12.5 Amp (1500 W), 1.5 HP - 140 V
1.5 HP - 140 V, 3 HP - 240 V,
Double Pole, Single Throw Contacts
RC615 Timer Interface Module
Same as RC613
without Manual Button
Size
Shipping Weight
4-1/2" H (11.4 cm)
3" W (7.6 cm), 1-1/4" D (4.0 cm)
Same as RC613
7-3/4" H (19.7 cm)
4" W (10.7 cm)
3-1/2" D (8.9 cm)
0.5 lbs (0.2 kg)
0.7 lbs (0.3 kg)
1.4 lbs (0.6 kg)
Same as RC613
0.5 lbs (0.2 kg)
RC613L
Hand Held Radio Transmitter
This hand held radio transmitter operates the shared equipment of a pool/spa combination by the touch
of a button. In addition, more buttons are available on the transmitter to turn ON-OFF a booster pump,
a blower and lights.
Applications
• Pool-Spa Combinations
• Water Features
Specifications
Enclosure – Beige plastic, 4-3/8" (11.1 cm) H, 2-3/4" (7.0 cm) W and 1" (2.5 cm) D.
Model #
Description
Range*
Battery
Shipping Weight
RC939
3 Channel Radio Transmitter
100 ft.
9V Transistor type
0.5 lbs (0.2 kg)
* The range is 100 feet but depends on many factors like the age of the battery, proximity of large metal objects, the location of the receiver
and environmental conditions at the time of transmission.
RC939
84
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Portable Outdoor Timers
P1200 Series
Two-Circuit Portable Outdoor Timer
These Portable Two-circuit Above Ground Pool Timers incorporate a plug in for a timed circuit (normally used
for a pool pump) and a plug in for a live circuit (typically used for a pool light). GFCI protected circuits and a
three-prong grounded plug for the time switch supply are also built-in.
Applications
• Above ground pool pumps
• Above ground pool lights
P1261P
Specifications
Case - NEMA 3R rated for indoor-outdoor installation.
9-3/8” (23.8 cm) high x 5-1/2” (14.0 cm) wide x 3-5/8” (9.2 cm) deep
Knockouts - Combination 1/2” - 3/4” nominal knockouts, one on the back and each side of case, two
pre-cut on bottom
Timer - 24 hour with 23-1/2 hour maximum ON time. Two ON, two OFF trippers - standard. Dial will accept
up to 12 sets of trippers.
Shipping Weight - 2.8 lbs. (1.3kg)
Model
Description
Electrical
Plug & Receptacle
P1261P
PB913N84 Timer
5-15
P1261PE
PB313E Electronic Timer
15 Amp (1800 W), Resistive or
Tungsten 1 HP, 15 FLA (96 LRA)
Motor Load
15 Amp (1800 W), Resistive or
Tungsten 1 HP, 15 FLA (96 LRA)
Motor Load
P1261PE
5-15
For additional trippers ( 2 “ON” 2 “ OFF” per pack ), order No. 156PB10398A
P1100 Series
Portable Outdoor Timers – Heavy Duty Outdoor Timers
These Portable Outdoor Timers are specially designed to control the filter pump of a portable pool or spa, but
they can also be used to turn ON and OFF (in off-season) outdoor decoration, engine block heaters and other
appliances, indoors or outdoors.
P1101
Applications
• Filter Pumps
• Signs
• Engine Block Heaters
• Air Conditioners
• Lights
• Fans
P1121
Specifications
Case – Outdoor grade plastic. 5" (12.7 cm) H x 5-1/2" (13.97 cm) W x 3-3/4" (9.52 cm) D. Cord – 3 wire,
outdoor grade, 22" long.
Timer – 24 hour with 23-1/2 hour maximum ON time. Two ON, two OFF trippers - standard. Dial will accept
up to 12 sets of trippers.
Shipping Weight – 1.7 lbs (0.7 kg)
Model #
Description
Electrical
P1101
Timer
P1121
Timer
P1131
Heavy-Duty Timer with
Twist-Lock Plug & Receptacle
Safety Timer with Ground Fault Circuit Protection
15 Amp (1800 W), Resistive or Tungsten
1 HP Air Conditioner, 15 FLA (96 LRA), Motor Load
15 Amp (1800 W), Resistive or Tungsten
1 HP Air Conditioner, 15 FLA (96 LRA), Motor Load
Resistive, 1 HP, 16 FLA (96 LRA) Motor Load
5-15
5L-20
15 Amp (1800 W) Resistive, Tungsten
15 FLA (90 LRA) Motor
5-15
P1161
Plug & Receptacle
5-15
P1131
P1161
For additional trippers ( 2 “ON” 2 “ OFF” per pack ), order No. 156PB10398A
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
85
Pool/Spa Accessories
PJB Series
Pool/Spa Junction Box & Mounting Bracket
PJB4175
PJB2175
These polymeric, water tight, multi-fixture Junction Boxes are especially designed for pools, pool-spa combinations and landscape applications. The PJB4175 provides safe and reliable connection for up to four lights.
While the PJB2175 supports up to two lights. They will accommodate flexible cords from #16-3 up to #12-3
and #10-3 in any combination and non-metallic conduits from 1/2 to 1 inch, including one for supply
conductor feed. An optional wall/post mounting bracket is also available.
Applications
• Pool Lights
• Spa Lights
• Landscape Lights
Specifications
Case – Outdoor grade plastic. PJB4175 - 7.5" L x 4.75" W x 5.0" D. PJB2175 - 7.0" L x 3.0" W x 4.0" D
PA114
Model #
Description
PJB2175
PJB4175
PA114
Pool/Spa Light Junction Box
Pool/Spa Light Junction Box
Wall/Post Mounting Bracket
Light Connection
Case Qty.
Shipping Weight
2
4
—
24
12
10
19.2 lbs (8.6 kg)
13.2 lbs (6.0 kg)
5lbs (2.3 kg)
PAV Series
Maintenance Free Water Valves
Intermatic’s Maintenance Free Water Valves have been designed to provide reliable control of water flow to
pools, spas, solar collectors, cleaners and water features. These 2-way and 3-way valves have excellent flow
characteristics while maintaining back pressure. Manufactured with Intermatic’s high quality standards, the
PAV Series Water Valves offer long maintenance free performance
PAV320
Applications
• Pools
• Spas
• Fountains
• Water Features
PAV220C
Standard Features
• Teflon-coated diverter requires no lubrication and ensures maintenance free performance
• Innovative field adjustable stop ensures precise valve positioning
• 1-1/2” valves fit 1-1/2” and 2” plumbing, 2” plumbing, 2” valves fit 2” and 2-1/2” plumbing
• Available in standard PVC and high temperature CPVC
Model
For maximum convenience in
pool/spa automation, PAV Series
water valves can be used in
conjunction with Intermatic PE24VA
valve actuators.
86
PAV215
PAV215C
PAV220
PAV220C
PAV315
PAV315C
PAV320
PAV320C
Port Size
Configuration
Material
Shipping Weight Each
1-1/2”
1-1/2”
2”
2”
1-1/2”
1-1/2”
2”
2”
2-WAY
2-WAY
2-WAY
2-WAY
3-WAY
3-WAY
3-WAY
3-WAY
PVC
CPVC
PVC
CPVC
PVC
CPVC
PVC
CPVC
1.5 lbs (0.6 kg)
1.5 lbs (0.6 kg)
1.6 lbs (0.7 kg)
1.6 lbs (0.7 kg)
1.5 lbs (0.6 kg)
1.5 lbs (0.6 kg)
1.6 lbs (0.7 kg)
1.6 lbs (0.7 kg)
Model #
Description
Voltage
Shipping Weight Each
PE24VA
Valve Actuator
24 VAC
3.5 lbs (2.2 kg)
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Setting a New Standard for Protection
The same quality and coverage you’ve come to expect
from Intermatic controls can also be found in a
complete line of panel-mount and point-of-use
surge protection — from high current capacity
industrial models to residential models, with
integrated phone and coax protection.
On average, the typical home or
business gets hit with more than
2,000 electrical surges annually,
costing home and business
owners more than $26 billion
dollars. As more and more
homes begin housing more
elaborate home theater and
entertainment systems,
home offices and other
appliances, it is becoming
increasingly important to
protect all electronic
investments from transient
voltage or “bad power.”
87
Why Every Facility Needs Surge Protection
1.0
V(t)/Vp
Electrical disturbances and downtime cost North American Companies more than $26 billion every year. Every
process within your building is controlled by electrical and electronic components which all require surge
protection to function reliably.
0.8
RISE TIME = 1.2 s
0.6
DURATION = 50 s
0.4
0.2
0.0
0
20
40
60
80 TIME .s 100
Voltage Waveform
ANSI/IEEE has defined common disturbances which occur in modern facilities per the waveforms to the left.
Depending on the proximity of the equipment to your power entry points, the severity increases. As the transient
event propagates throughout your building, it degrades your electronic components by stressing them with
excess voltage and current.
Every modern facility is a strong candidate for protection. Intermatic has a broad line of Service Entrance,
Panelboard and Point-of-Use Protection to select from.
1.0
l(t)/lp
0.8
Service Entrance, Panelboard and Point-of-Use surge protection can be found in the following
types of facilities and installations:
FRONT TIME = 8 s
0.6
DURATION = 20 s
0.4
0.2
0.0
0
10
20
30
40 TIME .s
50
Current Waveform
1.0
• Manufacturing
• Healthcare/Medical
• Education/University
• Data Centers
• Telecom/Cell Sites
• Utility
• Correctional
• Military Installations
• Airports
• Broadcast Studios
• Financial Institutions
• Retail
• General Office
• Semiconductor Fabrication
• Wastewater Facilities
• Restaurants
• Entertainment Facilities
RISE TIME = 0.5 s
V(t)/Vp
10 s
0.6
Virtually all devices which are powered by electricity are vulnerable. Surge Suppression
is required for protection of the following types of systems:
0.4
0.2
-0.0
-0.2
-0.4
-0.6
-0.8
-1.0
-1.2
0
10
20
TIME .s
30
100 kHz Ringwave
System Voltage
The wiring diagrams characterize common voltage
configurations available for the products. Refer to
individual product pages for models available
in below configurations. Match the voltage
configuration below with your voltage configuration
at your Service Entrance, Distribution Panel or
Panelboard location where you want protection.
• Computer/Peripherals
• Network Servers/ Routers/Modems
• Telecom Equipment
• Variable Frequency Drives
• Lighting Ballasts
• HVAC Controls
• Fire Alarm Systems
• Security Systems
• Lighting Control and Dimming Systems
• Automatic Test Equipment
• Wafer Fabrication Equipment
• Uninterruptible Power Supplies
• Bar Code Scanning Equipment
• Programmable Logic Controllers
• CNC Machines
• Pumps, motors and related equipment
which has electronic controls or starters
Surge Suppression Definitions
Surge Current Capacity is the rated surge current that a design will withstand based on the standard
8 x 20 microsecond current waveform. Nema LS-1 states that this should be given for each mode of a surge
protection device, since devices can have different components in each mode.
Modes of Protection are the coupling paths that exist in a single or three phase system.
In a three phase wye system there are 10 potential modes where a transient can be coupled:
L1 to Neutral
L3 to Neutral
L3 to L1
120/240 Volt
120/208 Volt
120 Volt
Single Phase
Three Phase Wye
Single Phase
2 Wire plus Ground 3 Wire plus Ground 4 Wire plus Ground
(split phase)
L1 to Ground
L3 to Ground
Neutral to Ground
L2 to Neutral
L1 to L2
L2 to Ground
L2 to L3
In a three phase delta system there are six potential modes where a transient can be coupled:
L1 to Ground
L1 to L2
L2 to Ground
L2 to L3
L3 to Ground
L3 to L1
All modes must have suppression components coupled between them in order to be 100% effective.
120/240 Volt
240 Volt
277/480 Volt
Three Phase HLD Three Phase Delta Three Phase Wye
(High Leg Delta)
3 Wire plus Ground 4 Wire plus Ground
4 Wire plus Ground
MCOV (Maximum Continuous Operating Voltage) is the maximum steady state rms voltage at which the unit
can safely operate.The recommended MCOV is 115% of nominal voltage for all voltage configurations.
EMI/RFI Noise Attenuation is a way to rate filter performance over a range of specific frequencies. IEEE
characterizes line noise as less than two times peak voltage. Line noise can be somewhat attenuated by the
capacitance found in MOVs, but typically requires the addition of capacitors to increase effectiveness. EMI/RFI
filters should be UL1283 Listed for safety.
600 Volt
347/600 Volt
480 Volt
Three Phase Delta Three Phase Wye Three Phase Delta
3 Wire plus Ground 4 Wire plus Ground 3 Wire plus Ground
88
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Standards and Guidelines
ANSI/IEEE C62.41.1-2002 and ANSI/IEEE C62.41.2-2002 are the recognized American National Standards for
establishing the surge withstand capability of equipment connected to utility power circuits in residential,
commercial or industrial applications. The standard has established the following Location Categories which
can be applied to virtually any type of facility.
Category C
Category B
Category A
• Outside and Service Entrance
• Any underground lines
• Overhead line to detached building
• Feeders and short branch circuits
• Distribution panel devices
• Lighting systems in large buildings
• Outlets and long branch circuits
Service
Entrance
Meter
Service
Entrance
Meter
The following values and waveforms are recognized within Categories C, B and A. Location Category C is the
Outside and Service Entrance and the harshest surge environment.
Combination Waves
Ring Waves
1.2 x 50 microsecond / 8 x 20 microsecond
100KHz 0.5 microsecond
Location Voltage (Peak)
Category 1.2 x 50 μ sec.
Current (Peak)
8 x 20 μ sec.
Location
Category
Voltage
(peak)
Current
(peak)
A
B
C low
C high
500 Amp
3,000 Amp
3,000 Amp
10,000 Amp
A
B
6,000 Volts
6,000 Volts
200 Amp
500 Amp
6,000 Volt
6,000 Volt
6,000 Volt
10,000 Volt
The following guidelines can be followed for Intermatic products:
Large Service Entrance (2000 to 4000 Amperes)
Best
PG5001-480-3DLL
PG5001-480-3Y
Better
PG4501-480-3DLL
PG4501-480-3Y
Good
PG4001-480-3DLL
PG4001-480-3Y
Small Service Entrance (Less than 1600 Amperes)
Best
PG4501-480-3DLL
PG4501-480-3Y
Better
PG4001-480-3DLL
PG4001-480-3Y
Good
PG100-480-3DLL
PG100-480-3Y
Large Distribution Panel (1000 to 1600 Amperes)
Best
PG4001-480-3DLL
PG4001-480-3Y
Better
PG100-480-3DLL
PG100-480-3Y
Good
PG80-480-3DLL
PG80-480-3Y
Small Distribution Panel (600 to 1000 Amperes)
Best
PG100-480-3DLL
PG100-480-3Y
Better
PG80-480-3DLL
PG80-480-3Y
Good
PG60-480-3DLL
PG60-480-3Y
Large Panelboard (225 to 400 Amperes)
Best
PG80-480-3DLL
PG80-480-3Y
Better
PG60-480-3DLL
PG60-480-3Y
Good
PG40-480-3D
PG40-480-3Y
Small Panelboard (60 to 200 Amperes)
Best
PG60-480-3DLL
PG60-480-3Y
Better
PG40-480-3D
PG40-480-3Y
Good
PG20-480-3D
PG20-480-3Y
B
A
Nema Standard LS-1 is the National Electrical
Manufacturers Association specification guideline for low
voltage surge protection devices.
Underwriters Laboratories – UL1449 has recently
been revised (August 1998) and requires surge
suppression devices to safely pass overvoltage tests,
abnormal overvoltage tests, short circuit withstand tests as
well as assigns suppress voltage ratings based on a 6 KV,
500 Amp combination wave or impulse.
Product Selection Chart – Surge Suppression Recommendations
Choose Model by Voltage and distance from incoming Service
Location
480 VAC
277/480 VAC
120/208 VAC Wye
C
ANSI/IEEE C62.45 is the American National Standard for
uniform testing of surge suppression devices. All
Intermatic testing follows these guidelines.
Refer to Page
PG5001-208-3Y
PG4501-208-3Y
PG4001-208-3Y
90
91
92
PG4501-208-3Y
PG4001-208-3Y
PG100-208-3Y
91
92
93
PG4001-208-3Y
PG100-208-3Y
PG80-208-3Y
92
93
95
PG100-208-3Y
PG80-208-3Y
PG60-208-3Y
93
95
97
PG80-208-3Y
PG60-208-3Y
PG40-208-3Y
95
97
100
PG60-208-3Y
PG40-208-3Y
PG20-208-3Y
97
100
102
Note for the PG 60/80/100 models equivalent models are available in Nema 3R enclosures for outdoor applications (see PG2500, PG3000,
PG3500 Series).
UL1283 – The safety standard for EMI/RFI noise
attenuation filters. While this device does not rate filters or
performance – it does provide a level of testing to ensure
the filter is safe for commercial application.
There are four main factors to consider
when specifying the appropriate device
for your facility:
1. What is the amperage (size) of the
Switchboard or Panelboard at the point of
installation?
2. What is the geographic location of the
facility?(i.e. the relative level of lightning
exposure and utility grid switching activity)
3. What is the density of electronic equipment
and how critical is the application?
(i.e. a 7 x 24 computer data center would require a
higher level of protection than a retail store)
4. What is the level of transient and noise
producing loads within your facility?
(i.e. a heavy industrial manufacturing environment
or a densely populated computer data center would
require a higher level of protection)
NOTES:
• Pick appropriate model to match the voltage of your Service
Entrance, Distribution Panel or Panelboard.
• See individual product pages for other available voltages.
• A facility without any Service Entrance protection would warrant
a higher level of protection at downstream locations.
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
89
Surge Suppression System
PG5000 Series
Features
• All mode Protection (L-N, L-G, N-G, L-L)
• 40 kA Brute Force MOVs
• 200 KAIC Surge Rated Fuses
• Fault Current Tested to 200 KAIC
• Easily Replaceable Master Surge Module
• NEMA 3R Style Enclosure
• Redundant Protection per mode
400kA
PER
PHASE
• Safety Interlocked Disconnect
• Thermally Protected MOVs for maximum safety
• EMI/RFI Filtration – Up to 54 dB from 20 kHz to 100 MHz
• UL1449, 2nd Edition and UL1283 Listed, cULus
• Lugs accept #10 to #2 AWG
• 10 year product warranty
• Complementary Listed as Secondary Surge Arrester (OWHX,E135626)
Integral Diagnostics
• LED Indicator Lights
• Form C Contacts
• Intermatic Thermal Monitoring System
• Digital Surge Counter
• Audible Alarm
Surge Current Capacity
(8 x 20 usec) (per mode)2
Per
Phase3
Intermatic
MCOV1
Model
L-G
L-N
L-G
N-G
L-L
PG5001-240-2S 120/240 VAC Single Phase (split)
115%
200 kA
200 kA
200 kA 200 kA
PG5001-208-3Y 120/208 VAC Three Phase Wye
115%
200 kA
200 kA
200 kA 200 kA
PG5001-240-3HLD 120/240 VAC Three Phase High Leg Delta
115%
200 kA
200 kA
200 kA 200 kA
The PG5000 Series is a hardwired
suppression device (installed in
parallel) and recommended for all
ANSI/IEEE Category locations.
Dimensions:
28.66"H x 15.11"W x 8.05"D
Weight: 65 lbs.
PG5001-480-3Y 277/480 VAC Three Phase Wye
115%
200 kA
200 kA
200 kA
PG5001-480-3DLL 480 VAC Three Phase Delta
115%
—
—
—
PG5001-600-3Y 347/600 VAC Three Phase Wye
115%
200 kA
200 kA
200 kA
PG5001-600-3D 600 VAC Three Phase Delta
115%
—
200 kA
—
UL 1449 Clamping Voltage (SVR)
6 kV, 500 Amp (8 x 20 usec)4
L-N
L-G
N-G
L-L
400 kA
400 V
400 V
330 V
700 V
400 kA
400 V
400 V
330 V
700 V
400 kA
400 V /
(700 V)
400 V /
(700 V)
330 V
900 V
200 kA
400 kA
800 V
700 V
700 V
1,500 V
200 kA
200 kA
—
—
—
1,500 V
200 kA
400 kA
1,000 V
1,000 V
1,000 V
1,800 V
200 kA
400 kA
—
1,500 V
—
1,800 V
NOTES:
1
MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage.
2
All surge currents listed above are independently tested and verified per NEMA LS-1.
3 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems.
4
Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition.
90
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Surge Suppression System
PG4500 Series
Features
• All mode Protection (L-N, L-G, N-G, L-L)
• 40 kA Brute Force MOVs
• 200 KAIC Surge Rated Fuses
• Fault Current Tested to 200 KAIC
• Easily Replaceable Master Surge Module
• NEMA 3R Style Enclosure
• Redundant Protection per mode
• Safety Interlocked Disconnect
• Thermally Protected MOVs for maximum safety
• EMI/RFI Filtration – Up to 54 dB from 20 kHz to 100 MHz
• UL1449, 2nd Edition and UL1283 Listed, cULus
• Lugs accept #10 to #2 AWG
• 10 year product warranty
• Complementary Listed as Secondary Surge Arrester (OWHX,E135626)
300kA
PER
PHASE
Integral Diagnostics
• LED Indicator Lights
• Form C Contacts
• Intermatic Thermal Monitoring System
• Digital Surge Counter
• Audible Alarm
Surge Current Capacity
(8 x 20 usec) (per mode)2
Per
Phase3
Intermatic
MCOV1
Model
L-G
L-N
L-G
N-G
L-L
PG4501-240-2S 120/240 VAC Single Phase (split)
115%
150 kA
150 kA
150 kA 150 kA
PG4501-208-3Y 120/208 VAC Three Phase Wye
115%
150 kA
150 kA
150 kA 150 kA
PG4501-240-3HLD 120/240 VAC Three Phase High Leg Delta
115%
150 kA
150 kA
150 kA 150 kA
PG4501-480-3Y 277/480 VAC Three Phase Wye
115%
150 kA
150 kA
150 kA
PG4501-480-3DLL 480 VAC Three Phase Delta
115%
—
—
—
PG4501-600-3Y 347/600 VAC Three Phase Wye
115%
150 kA
150 kA
150 kA
PG4501-600-3D 600 VAC Three Phase Delta
115%
—
150 kA
—
UL 1449 Clamping Voltage (SVR)
6 kV, 500 Amp (8 x 20 usec)4
L-N
L-G
N-G
L-L
300 kA
400 V
400 V
330 V
700 V
300 kA
400 V
400 V
330 V
700 V
300 kA
400 V /
(700 V)
400 V /
(700 V)
330 V
900 V
150 kA
300 kA
800 V
700 V
700 V
1,500 V
150 kA
150 kA
—
—
—
1,500 V
150 kA
300 kA
1,000 V
1,000 V
1,000 V
1,800 V
150 kA
300 kA
—
1,500 V
—
1,800 V
The PG4500 Series is a hardwired
suppression device (installed in
parallel) and recommended for all
ANSI/IEEE Category locations.
Dimensions:
28.66"H x 15.11"W x 8.05"D
Weight: 65 lbs.
NOTES:
1
MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage.
2
All surge currents listed above are independently tested and verified per NEMA LS-1.
3 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems.
4
Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition.
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
91
Surge Suppression System
PG4000 Series
Features
• All mode Protection (L-N, L-G, N-G, L-L)
• Safety Interlocked Disconnect
• 40 kA Brute Force MOVs
• Thermally Protected MOVs for maximum safety
• 200 KAIC Surge Rated Fuses
• EMI/RFI Filtration – Up to 54 dB from 20 kHz to 100 MHz
• Fault Current Tested to 200 KAIC
• UL1449, 2nd Edition and UL1283 Listed, cULus
• Easily Replaceable Master Surge Module
• Lugs accept #10 to #2 AWG
• NEMA 3R Style Enclosure
• 10 year product warranty
• Redundant Protection per mode
• Redundant Protection per mode
• Complementary Listed as Secondary Surge Arrester (OWHX,E135626)
250kA
PER
PHASE
Integral Diagnostics
• LED Indicator Lights
• Form C Contacts
• Intermatic Thermal Monitoring System
• Digital Surge Counter
• Audible Alarm
Surge Current Capacity
(8 x 20 usec) (per mode)2
The PG4000 Series is a hardwired
suppression device (installed in
parallel) and recommended for all
ANSI/IEEE Category locations.
Dimensions:
28.66"H x 15.11"W x 8.05"D
Weight: 65 lbs.
Per
Phase3
Intermatic
MCOV1
Model
L-G
L-N
L-G
N-G
L-L
PG4001-240-2S 120/240 VAC Single Phase (split)
115%
125 kA
125 kA
125 kA 125 kA
PG4001-208-3Y 120/208 VAC Three Phase Wye
115%
125 kA
125 kA
125 kA 125 kA
PG4001-240-3HLD 120/240 VAC Three Phase High Leg Delta
115%
125 kA
125 kA
125 kA 125 kA
PG4001-480-3Y 277/480 VAC Three Phase Wye
115%
125 kA
125 kA
125 kA
PG4001-480-3DLL 480 VAC Three Phase Delta
115%
—
—
—
PG4001-600-3Y 347/600 VAC Three Phase Wye
115%
125 kA
125 kA
125 kA
PG4001-600-3D 600 VAC Three Phase Delta
115%
—
125 kA
—
UL 1449 Clamping Voltage (SVR)
6 kV, 500 Amp (8 x 20 usec)4
L-N
L-G
N-G
L-L
250 kA
400 V
400 V
330 V
700 V
250 kA
400 V
400 V
330 V
700 V
250 kA
400 V /
(700 V)
400 V /
(700 V)
330 V
900 V
125 kA
250 kA
800 V
700 V
700 V
1,500 V
125 kA
125 kA
—
—
—
1,500 V
125 kA
250 kA
1,000 V
1,000 V
1,000 V
1,800 V
125 kA
250 kA
—
1,500 V
—
1,800 V
NOTES:
1
MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage.
2
All surge currents listed above are independently tested and verified per NEMA LS-1.
3
Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems.
4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition.
92
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Surge Suppression System
PG100 Series
Features
• Panel Extension design for mounting above or below 20" wide panel
• Available wiring space on each side for branch circuit or main input conductors
• All mode Protection (L-N, L-G, N-G, L-L)
• Redundant Protection per mode, replaceable master module
• Integral 200 KAIC fusing and thermal protection
• Fault Current Tested to 200 KAIC
• Complementary Listed as Secondary Surge Arrester (OWHX,E135626)
• UL1449, 2nd Edition and UL1283 Listed, cULus
• NEMA 12 Style Enclosure
• Lugs accept #10 to #2 AWG
• Available with flush mount cover PG1-FMP
• 10 year product warranty
• EMI/RFI Filtration – Up to 54 dB from 20 kHz to
100 MHz
Integral Diagnostics
• LED Indicator Lights for each mode
• Form C Contacts
• Audible Alarm
Surge Current Capacity
(8 x 20 usec) (per mode)2
Per
Phase3
Intermatic
MCOV1
Model
L-G
L-N
L-G
N-G
L-L
PG100-240-2S 120/240 VAC Single Phase (split)
115%
100 kA
100 kA
100 kA 100 kA
PG100-208-3Y 120/208 VAC Three Phase Wye
115%
100 kA
100 kA
100 kA 100 kA
PG100-240-3HLD 120/240 VAC Three Phase High Leg Delta
115%
100 kA
100 kA
100 kA 100 kA
PG100-480-3Y 277/480 VAC Three Phase Wye
115%
100 kA
100 kA
100 kA
PG100-480-3DLL 480 VAC Three Phase Delta
115%
—
—
—
UL 1449 Clamping Voltage (SVR)
6 kV, 500 Amp (8 x 20 usec)4
L-N
L-G
N-G
L-L
200 kA
330 V
330 V
330 V
600 V
200 kA
330 V
330 V
330 V
600 V
200 kA
330 V
(600 V)
330 V
(700 V)
330 V
900 V
100 kA
200 kA
800 V
800 V
700 V
1,500 V
100 kA
100 kA
—
—
—
1,200 V
200kA
PER
PHASE
The PG100 Series is a hard wired
suppression device installed in
parallel) and recommended for all
ANSI/IEEE Category locations.
Dimensions:
16.0”H x 20.0”W x 6.0”D
Weight: 40 lbs
NOTES:
1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage.
2
All surge currents listed above are independently tested and verified per NEMA LS-1.
3
Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems.
4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition.
Flush Mount Plate PG1-FMP
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
93
Surge Suppression System
PG3500 Series
Features
• All mode Protection (L-N, L-G, N-G, L-L)
• Redundant Protection per mode
• 40 kA Brute Force MOVs
• Thermally Protected MOVs for maximum safety
• 200 KAIC Surge Rated Fuses
• EMI/RFI Filtration – Up to 54 dB from 20 kHz to 100 MHz
• Fault Current Tested to 200 KAIC
• UL1449, 2nd Edition and UL1283 Listed, cULus
• Easily Replaceable Master Surge Module
• Lugs accept #10 to #2 AWG
• NEMA 3R Style Enclosure
• 10 year product warranty
• Complementary Listed as Secondary Surge Arrester (OWHX,E135626)
200kA
PER
PHASE
Integral Diagnostics
• LED Indicator Lights
• Intermatic Thermal Monitoring System
• Audible Alarm
• Form C Contacts
Surge Current Capacity
(8 x 20 usec) (per mode)2
Per
Phase3
Intermatic
MCOV1
Model
L-G
L-N
L-G
N-G
L-L
PG3500-240-2S 120/240 VAC Single Phase (split)
115%
100 kA
100 kA
100 kA 100 kA
PG3500-208-3Y 120/208 VAC Three Phase Wye
115%
100 kA
100 kA
100 kA 100 kA
PG3500-240-3HLD 120/240 VAC Three Phase High Leg Delta
115%
100 kA
100 kA
100 kA 100 kA
The PG3500 Series is a hardwired
suppression device (installed in
parallel) and recommended for all
ANSI/IEEE Category locations.
Dimensions:
28.66"H x 15.11"W x 8.05"D
Weight: 60 lbs.
PG3500-480-3Y 277/480 VAC Three Phase Wye
115%
100 kA
100 kA
100 kA
PG3500-480-3DLL 480 VAC Three Phase Delta
115%
—
—
—
PG3500-600-3Y 347/600 VAC Three Phase Wye
115%
100 kA
100 kA
100 kA
PG3500-600-3D 600 VAC Three Phase Delta
115%
—
100 kA
—
UL 1449 Clamping Voltage (SVR)
6 kV, 500 Amp (8 x 20 usec)4
L-N
L-G
N-G
L-L
200 kA
400 V
400 V
330 V
700 V
200 kA
400 V
400 V
330 V
700 V
200 kA
400 V /
(700 V)
400 V /
(700 V)
330 V
900 V
100 kA
200 kA
800 V
700 V
700 V
1,500 V
100 kA
100 kA
—
—
—
1,500 V
100 kA
200 kA
1,000 V
1,000 V
1,000 V
1,800 V
100 kA
200 kA
—
1,500 V
—
1,800 V
NOTES:
1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage.
2
All surge currents listed above are independently tested and verified per NEMA LS-1.
3
Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems.
4
Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition.
94
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Surge Suppression System
PG80 Series
Features
• Panel Extension design for mounting above or below 20" wide panel
• Available wiring space on each side for branch circuit or main input conductors
• All mode Protection (L-N, L-G, N-G, L-L)
• Redundant Protection per mode, replaceable master module
• Integral 200 KAIC fusing and thermal protection
• EMI/RFI Filtration – Up to 54 dB from 20 kHz to 100 MHz
• Complementary Listed as Secondary Surge Arrester (OWHX,E135626)
• UL1449, 2nd Edition and UL1283 Listed, cULus
• NEMA 12 Style Enclosure
• Lugs accept #10 to #2 AWG
• Available with flush mount cover PG1-FMP
• 10 year product warranty
• Fault Current Tested to 200 KAIC
160kA
PER
PHASE
Integral Diagnostics
• LED Indicator Lights for each mode
• Form C Contacts
• Audible Alarm
Surge Current Capacity
(8 x 20 usec) (per mode)2
Per
Phase3
Intermatic
MCOV1
Model
L-G
L-N
L-G
N-G
L-L
PG80-240-2S 120/240 VAC Single Phase (split)
115%
80 kA
80 kA
80 kA
80 kA
PG80-208-3Y 120/208 VAC Three Phase Wye
115%
80 kA
80 kA
80 kA
80 kA
PG80-240-3HLD 120/240 VAC Three Phase High Leg Delta
115%
80 kA
80 kA
80 kA
80 kA
PG80-480-3Y 277/480 VAC Three Phase Wye
115%
80 kA
80 kA
80 kA
PG80-480-3DLL 480 VAC Three Phase Delta
115%
—
80 kA
—
UL 1449 Clamping Voltage (SVR)
6 kV, 500 Amp (8 x 20 usec)4
L-N
L-G
N-G
L-L
160 kA
330 V
330 V
330 V
600 V
160 kA
330 V
330 V
330 V
600 V
160 kA
330 V
(600 V)
330 V
(700 V)
330 V
900 V
80 kA
160 kA
800 V
800 V
700 V
1500 V
80 kA
80 kA
—
—
—
1,200 V
The PG80 Series is a hardwired
suppression device (installed in
parallel) and recommended for all
ANSI/IEEE Category locations.
Dimensions:
16.0"H x 20.0"W x 6.0"D
Weight: 40 lbs.
NOTES:
1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage.
2
All surge currents listed above are independently tested and verified per NEMA LS-1.
3
Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems.
4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition.
Flush Mount Plate PG1-FMP
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
95
Surge Suppression System
PG3000 Series
Features
• All mode Protection (L-N, L-G, N-G, L-L)
• 40 kA Brute Force MOVs
• Thermally Protected MOVs for maximum safety
• EMI/RFI Filtration – Up to 54 dB from 20 kHz to 100 MHz
• UL1449, 2nd Edition and UL1283 Listed, cULus
• 10 year product warranty
160kA
PER
PHASE
• Redundant Protection per mode
• 200 KAIC Surge Rated Fuses
• Fault Current Tested to 200 KAIC
• Easily Replaceable Master Surge Module
• NEMA 3R Style Enclosure
• Complementary Listed as Secondary Surge Arrester
(OWHX,E135626)
Integral Diagnostics
• LED Indicator Lights
• Intermatic Thermal Monitoring System
• Audible Alarm
• Form C Contacts
Surge Current Capacity
(8 x 20 usec) (per mode)2
The PG3000 Series is a hardwired
suppression device (installed in
parallel) and recommended for all
ANSI/IEEE Category locations.
Dimensions:
28.66"H x 15.11"W x 8.05"D
Weight: 60 lbs.
Per
Phase3
Intermatic
MCOV1
Model
L-G
L-N
L-G
N-G
L-L
PG3000-240-2S 120/240 VAC Single Phase (split)
115%
80 kA
80 kA
80 kA
80 kA
PG3000-208-3Y 120/208 VAC Three Phase Wye
115%
80 kA
80 kA
80 kA
80 kA
PG3000-240-3HLD 120/240 VAC Three Phase High Leg Delta
115%
80 kA
80 kA
80 kA
80 kA
PG3000-480-3Y 277/480 VAC Three Phase Wye
115%
80 kA
80 kA
80 kA
PG3000-480-3DLL 480 VAC Three Phase Delta
115%
—
—
—
PG3000-600-3Y 347/600 VAC Three Phase Wye
115%
80 kA
80 kA
80 kA
PG3000-600-3D 600 VAC Three Phase Delta
115%
—
80 kA
—
UL 1449 Clamping Voltage (SVR)
6 kV, 500 Amp (8 x 20 usec)4
L-N
L-G
N-G
L-L
160 kA
400 V
400 V
330 V
700 V
160 kA
400 V
400 V
330 V
700 V
160 kA
400 V /
(700 V)
400 V /
(700 V)
330 V
900 V
80 kA
160 kA
800 V
700 V
700 V
1,500 V
80 kA
80 kA
—
—
—
1,500 V
80 kA
160 kA
1,000 V
1,000 V
1,000 V
1,800 V
80 kA
160 kA
—
1,500 V
—
1,800 V
NOTES:
1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage.
2
All surge currents listed above are independently tested and verified per NEMA LS-1.
3
Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems.
4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition.
96
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Surge Suppression System
PG60 Series
Features
• Panel Extension design for mounting above or below 20" wide panel
• Available wiring space on each side for branch circuit or main input conductors
• All mode Protection (L-N, L-G, N-G, L-L)
• Redundant Protection per mode, replaceable master module
• Integral 200 KAIC fusing and thermal protection
• EMI/RFI Filtration – Up to 54 dB from 20 kHz to 100 MHz
• Complementary Listed as Secondary Surge Arrester (OWHX,E135626)
• UL1449, 2nd Edition and UL1283 Listed, cULus
• NEMA 12 Style Enclosure
• Lugs accept #10 to #2 AWG
• Available with flush mount cover PG1-FMP
• 10 year product warranty
• Fault Current Tested to 200 KAIC
Integral Diagnostics
120kA
PER
PHASE
• LED Indicator Lights for each mode
• Form C Contacts
• Audible Alarm
Surge Current Capacity
(8 x 20 usec) (per mode)2
Per
Phase3
Intermatic
MCOV1
Model
L-G
L-N
L-G
N-G
L-L
PG60-240-2S 120/240 VAC Single Phase (split)
115%
60 kA
60 kA
60 kA
60 kA
PG60-208-3Y 120/208 VAC Three Phase Wye
115%
60 kA
60 kA
60 kA
60 kA
PG60-240-3HLD 120/240 VAC Three Phase High Leg Delta
115%
60 kA
60 kA
60 kA
60 kA
PG60-480-3Y 277/480 VAC Three Phase Wye
115%
60 kA
60 kA
60 kA
PG60-480-3DLL 480 VAC Three Phase Delta
115%
—
—
—
UL 1449 Clamping Voltage (SVR)
6 kV, 500 Amp (8 x 20 usec)4
L-N
L-G
N-G
L-L
120 kA
330 V
330 V
330 V
600 V
120 kA
330 V
330 V
330 V
600 V
120 kA
330 V
(600 V)
330 V
(700 V)
330 V
900 V
60 kA
120 kA
800 V
800 V
700 V
1,500 V
60 kA
60 kA
—
—
—
1,200 V
The PG60 Series is a hardwired
suppression device (installed in
parallel) and recommended for all
ANSI/IEEE Category locations.
Dimensions:
16.0"H x 20.0"W x 6.0"D
Weight: 40 lbs.
NOTES:
1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage.
2
All surge currents listed above are independently tested and verified per NEMA LS-1.
3
Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems.
4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition.
Flush Mount Plate PG1-FMP
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
97
Surge Suppression System
PG2500 Series
Features
• All mode Protection (L-N, L-G, N-G, L-L)
• Redundant Protection per mode
• 200 KAIC Surge Rated Fuses
• Thermally Protected MOVs for maximum safety
• Fault Current Tested to 200 KAIC
• Complementary Listed as Secondary Surge Arrester (OWHX,E135626)
• EMI/RFI Filtration – Up to 54 dB from 20 kHz to 100 MHz
• UL1449, 2nd Edition and UL1283 Listed, cULus
• NEMA 3R Style Enclosure
• Pre-wired with 40" of #10 AWG wire leads
• 10 year product warranty
Integral Diagnostics
• LED Indicator Lights for each mode
• Form C Contacts
• Audible Alarm
Surge Current Capacity
(8 x 20 usec) (per mode)2
120kA
PER
PHASE
The PG2500 Series is a hardwired
suppression device (installed in
parallel) and recommended for all
ANSI/IEEE Category locations.
Dimensions:
16.47"H x 10.59"W x 4.9"D
Weight: 28 lbs.
Per
Phase3
Intermatic
MCOV1
Model
L-G
L-N
L-G
N-G
L-L
IG2401SECA 120/240 VAC Single-Phase (Split)
115%
60 kA
60 kA
60 kA
60 kA
IG2083YECA 120/208 VAC Three Phase Wye
115%
60 kA
60 kA
60 kA
60 kA
IG2403DECA 120/240 VAC Three Phase High Leg Delta
115%
60 kA
60 kA
60 kA
60 kA
IG4803YECA 277/480 VAC Three Phase Wye
115%
60 kA
60 kA
60 kA
IG4803DECA 480 VAC Three Phase Delta
115%
—
120 kA
—
UL 1449 Clamping Voltage (SVR)
6 kV, 500 Amp (8 x 20 usec)4
L-N
L-G
N-G
L-L
120 kA
400 V
400 V
330 V
600 V
120 kA
400 V
400 V
330 V
600 V
120 kA
400 V /
(600 V)
400 V /
(700 V)
330 V
700 V
60 kA
120 kA
800 V
800 V
400 V
1,500 V
60 kA
180 kA
—
1,500 V
—
1,200 V
NOTES:
1
MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage.
2
All surge currents listed above are independently tested and verified per NEMA LS-1.
3 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems.
4
Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition.
Flush Mount Plate IG1FMP-PG
98
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Surge Suppression System
PG2000 Series
Features
• All mode Protection (L-N, L-G, N-G, L-L)
• Redundant Protection per mode
• 200 KAIC Surge Rated Fuses
• Thermally Protected MOVs for maximum safety
• Fault Current Tested to 200 KAIC
• Complementary Listed as Secondary Surge Arrester (OWHX,E135626)
• EMI/RFI Filtration – Up to 54 dB from 20 kHz to 100 MHz
• UL1449, 2nd Edition and UL1283 Listed, cULus
• NEMA 3R Style Enclosure
• Pre-wired with 40" of #10 AWG wire leads
• 10 year product warranty
Integral Diagnostics
• LED Indicator Lights
• Form C Contacts
• Intermatic Thermal Monitoring System
Surge Current Capacity
(8 x 20 usec) (per mode)2
Intermatic
MCOV1
Model
L-G
IG2401ECS 120/240 VAC
115%
IG2083ECY 120/208 VAC
115%
IG2403ECD 120/240 VAC
115%
Per
Phase3
UL 1449 Clamping Voltage (SVR)
6 kV, 500 Amp (8 x 20 usec)4
60kA
PER
PHASE
L-N
L-G
N-G
Single-Phase (Split)
30 kA
30 kA
30 kA
Three Phase Wye
30 kA
30 kA
30 kA
Three Phase High Leg Delta
30 kA
30 kA
30 kA
IG4803ECY 277/480 VAC Three Phase Wye
115%
30 kA
30 kA
IG4803ECD 480 VAC Three Phase Delta
115%
—
60 kA
L-L
L-N
L-G
N-G
L-L
30 kA
60 kA
500 V
400 V
400 V
700 V
30 kA
60 kA
400 V
500 V
400 V
700 V
30 kA
60 kA
400 V /
(700 V)
400 V /
(700 V)
330 V
700 V
30 kA
30 kA
60 kA
800 V
800 V
400 V
1,500 V
—
30 kA
90 kA
—
1,500 V
—
1,500 V
The PG2000 Series is a hardwired
suppression device (installed in
parallel) and recommended for all
ANSI/IEEE Category locations.
Dimensions:
16.47"H x 10.59"W x 4.9"D
Weight: 28 lbs.
NOTES:
1
MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage.
2
All surge currents listed above are independently tested and verified per NEMA LS-1.
3 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems.
4
Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition.
Flush Mount Plate IG1FMP-PG
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
99
Surge Suppression System
PG40 Series
Features
• All mode Protection (L-N, L-G, N-G, L-L)
• Redundant Protection per mode
• Integral 200 KAIC fusing and thermal protection
• Thermally protected MOVs for maximum safety
• Fault current tested to 200 KAIC
• EMI/RFI Filtration – Up to 54 dB from 20 kHz to 100 MHz
• UL1449, 2nd Edition and UL1283 Listed, cULus
• NEMA 4 style enclosure
• Pre-wired with 30" of #10 AWG wire leads
• Available with flush mount cover PG2-FMP
• 10 year product warranty
• Complementary Listed as Secondary Surge Arrester
(OWHX,E135626)
Integral Diagnostics
• LED indicator lights for each mode
• Form C Contacts
• Audible alarm
Surge Current Capacity
(8 x 20 usec) (per mode)2
80kA
PER
PHASE
The PG40 Series is a hardwired
suppression device (installed in
parallel) and recommended for all
ANSI/IEEE Category locations.
Dimensions:
11.0"H x 5.875"W x 3.75"D
Weight: 22 lbs.
Per
Phase3
Intermatic
MCOV1
Model
L-G
L-N
L-G
N-G
L-L
PG40-240-2S 120/240 VAC Single Phase (split)
115%
40 kA
40 kA
40 kA
40 kA
PG40-208-3Y 120/208 VAC Three Phase Wye
115%
40 kA
40 kA
40 kA
40 kA
PG40-240-3HLD 120/240 VAC Three Phase High Leg Delta
115%
40 kA
40 kA
40 kA
40 kA
PG40-480-3Y 277/480 VAC Three Phase Wye
115%
40 kA
40 kA
40 kA
PG40-480-3D 480 VAC Three Phase Delta
115%
—
40 kA
—
UL 1449 Clamping Voltage (SVR)
6 kV, 500 Amp (8 x 20 usec)4
L-N
L-G
N-G
L-L
80 kA
330 V
330 V
400 V
700 V
80 kA
330 V
330 V
400 V
700 V
80 kA
330 V
(600 V)
330 V
(600 V)
400 V
900 V
40 kA
80 kA
800 V
800 V
800 V
1,500 V
40 kA
80 kA
—
1,200 V
—
1,200
NOTES:
1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage.
2
All surge currents listed above are independently tested and verified per NEMA LS-1.
3
Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems.
4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition.
Flush Mount Plate PG2-FMP
100
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Surge Suppression System
EH Series
Features
• All mode Protection (L-N, L-G, N-G, L-L)
• Redundant Protection per mode
• 200 KAIC Surge Rated Fuses
• Thermally Protected MOVs for maximum safety
• Fault Current Tested to 200 KAIC
• Complementary Listed as Secondary Surge Arrester (OWHX,E135626)
• EMI/RFI Filtration – 20 to 30 dB from 20 kHz to 100 MHz
• UL1449, 2nd Edition Listed, cULus
• NEMA 12 Style Enclosure
• Pre-wired with 30" of #10 AWG wire leads
• 10 year product warranty
Integral Diagnostics
• LED Indicator Lights
• Intermatic Thermal Monitoring System
Surge Current Capacity
(8 x 20 usec) (per mode)2
Per
Phase3
Intermatic
MCOV1
Model
L-G
L-N
L-G
N-G
L-L
IG1201EH 120 VAC Single Phase
115%
26 kA
26 kA
26 kA
—
IG2401EH 120/240 VAC Single Phase (split)
115%
26 kA
26 kA
26 kA
26 kA
IG2083YEH 120/208 VAC Three Phase Wye
115%
26 kA
26 kA
26 kA
26 kA
IG2403DEH 120/240 VAC Three Phase High Leg Delta
115%
26 kA
26 kA
26 kA
26 kA
IG4803YEH 277/480 VAC Three Phase Wye
115%
26 kA
26 kA
26 kA
IG4803DEH 480 VAC Three Phase Delta
115%
—
52 kA
—
UL 1449 Clamping Voltage (SVR)
6 kV, 500 Amp (8 x 20 usec)4
52kA
PER
PHASE
L-N
L-G
N-G
L-L
52 kA
500 V
500 V
500 V
—
52 kA
400 V
400 V
400 V
700 V
52 kA
400 V
400 V
400 V
700 V
52 kA
400 V /
(700 V)
400 V /
(700 V)
400 V
700 V
26 kA
52 kA
800 V
800 V
400 V
1,500 V
26 kA
78 kA
—
1,200 V
—
1,500 V
NOTES:
1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage.
2
All surge currents listed above are independently tested and verified per NEMA LS-1.
3
Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems.
4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition.
The EH Series is a hardwired
suppression device (installed in
parallel) and recommended for all
ANSI/IEEE Category locations.
Dimensions:
7.5"H x 4.25"W x 4.0"D
Weight: 5.5 lbs.
Flush Mount Plate IG1FMP-H
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
101
Surge Suppression System
PG20 Series
Features
• All mode Protection (L-N, L-G, N-G, L-L)
• Redundant Protection per mode
• Integral 200 KAIC fusing and thermal protection
• Thermally protected MOVs for maximum safety
• Fault current tested to 200 KAIC
• EMI/RFI Filtration – Up to 54 dB from 20 kHz to 100 MHz
• UL1449, 2nd Edition and UL1283 Listed, cULus
• NEMA 4 style enclosure
• Pre-wired with 30" of #10 AWG wire leads
• Available with flush mount cover PG2-FMP
• 10 year product warranty
• Complementary Listed as Secondary Surge Arrester
(OWHX,E135626)
Integral Diagnostics
• LED indicator lights for each mode
• Form C Contacts
• Audible alarm
Surge Current Capacity
(8 x 20 usec) (per mode)2
40kA
PER
PHASE
The PG20 Series is a hardwired
suppression device (installed in
parallel) and recommended for all
ANSI/IEEE Category locations.
Dimensions: 11.0"H x 5.875"W x
3.75"D
Weight: 22 lbs.
Per
Phase3
Intermatic
MCOV1
Model
L-G
L-N
L-G
N-G
L-L
PG20-240-2S 120/240 VAC Single Phase (split)
115%
20 kA
20 kA
20 kA
20 kA
PG20-208-3Y 120/208 VAC Three Phase Wye
115%
20 kA
20 kA
20 kA
20 kA
PG20-240-3HLD 120/240 VAC Three Phase High Leg Delta
115%
20 kA
20 kA
20 kA
20 kA
PG20-480-3Y 277/480 VAC Three Phase Wye
115%
20 kA
20 kA
20 kA
PG20-480-3D 480 VAC Three Phase Delta
115%
—
20 kA
—
UL 1449 Clamping Voltage (SVR)
6 kV, 500 Amp (8 x 20 usec)4
L-N
L-G
N-G
L-L
40 kA
330 V
330 V
400 V
700 V
40 kA
330 V
330 V
400 V
700 V
40 kA
330 V
(600 V)
330 V
(600 V)
400 V
900 V
20 kA
40 kA
800 V
800 V
800 V
1,500 V
20 kA
40 kA
—
1,200 V
—
1,200 V
NOTES:
1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage.
2
All surge currents listed above are independently tested and verified per NEMA LS-1.
3
Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems.
4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition.
Flush Mount Plate PG2-FMP
102
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Surge Suppression System
LH Series
Features
• All mode Protection (L-N, L-G, N-G, L-L)
• 200 KAIC Surge Rated Fuses
• Thermally Protected MOVs for maximum safety
• Fault Current Tested to 200 KAIC
• EMI/RFI Filtration – 20 to 30 dB from 20 kHz to 100 MHz
• UL1449, 2nd Edition, cULus
• NEMA 12 Style Enclosure
• Pre-wired with 30" of #10 AWG wire leads
• 10 year product warranty
• Complementary Listed as Secondary Surge Arrester
(OWHX,E135626)
Integral Diagnostics
26kA
PER
PHASE
• LED Indicator Lights
• Intermatic Thermal Monitoring System
Surge Current Capacity
(8 x 20 usec) (per mode)2
Per
Phase3
Intermatic
MCOV1
Model
L-G
L-N
L-G
N-G
L-L
IG1201LH 120 VAC Single Phase
115%
13 kA
13 kA
13 kA
—
IG2401LH 120/240 VAC Single Phase (split)
115%
13 kA
13 kA
13 kA
13 kA
IG2083LYH 120/208 VAC Three Phase Wye
115%
13 kA
13 kA
13 kA
13 kA
IG2403LDH 120/240 VAC Three Phase High Leg Delta
115%
13 kA
13 kA
13 kA
13 kA
IG4803LYH 277/480 VAC Three Phase Wye
115%
13 kA
13 kA
IG4803LDH 480 VAC Three Phase Delta
115%
—
26 kA
UL 1449 Clamping Voltage (SVR)
6 kV, 500 Amp (8 x 20 usec)4
L-N
L-G
N-G
L-L
26 kA
500 V
500 V
400 V
—
26 kA
400 V
500 V
400 V
700 V
26 kA
500 V
500 V
400 V
700 V
26 kA
500 V /
(700 V)
500 V /
(700 V)
500 V
700 V
13 kA
13 kA
26 kA
800 V
800 V
500 V
1,500 V
—
13 kA
39 kA
—
1,500 V
—
1,500 V
The LH Series is a hardwired
suppression device (installed in
parallel) and recommended for
ANSI/IEEE Category locations for A
and B.
Dimensions:
7.5"H x 4.25"W x 4.0"D
Weight: 5.5 lbs.
NOTES:
1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage.
2
All surge currents listed above are independently tested and verified per NEMA LS-1.
3
Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems.
4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition.
Flush Mount Plate IG1FMP-H
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
103
Surge Suppression System
PG1500 Series
Features
• L-N, N-G protection modes (4 mode)
• Redundant protection per mode
• Integral 200 KAIC fusing and thermal protection
• Thermally protected MOVs for maximum safety
• Fault current tested to 200 KAIC
• EMI/RFI filtration – Up to 54 dB from 20 kHz to 100 MHz
• UL1449, 2nd Edition and UL1283 Listed, cULus
• NEMA 4 style enclosure
• Pre-wired with 30" of #10 AWG wire leads
• Available with flush mount cover PG2-FMP
• 10 year product warranty
• Complementary Listed as Secondary Surge Arrester
(OWHX,E135626)
Integral Diagnostics
• LED indicator lights for each mode
• Form C Contacts
• Audible alarm
Surge Current Capacity
(8 x 20 usec) (per mode)2
80kA
PER
PHASE
The PG1500 Series is a hardwired
suppression device (installed in
parallel) and recommended for all
ANSI/IEEE Category locations.
Dimensions:
11.0"H x 5.875"W x 3.75"D
Weight: 22 lbs.
Intermatic
MCOV1
Model
L-N
L-N
L-G
N-G
PG1500-240-2S 120/240 VAC Single Phase (split)
115%
80 kA
—
40 kA
PG1500-208-3Y 120/208 VAC Three Phase Wye
115%
80 kA
—
40 kA
PG1500-480-3Y 277/480 VAC Three Phase Wye
115%
80 kA
—
40 kA
PG1500-480-3D 480 VAC Three Phase Delta
115%
—
80 kA
—
Per
Phase3
L-L
UL 1449 Clamping Voltage (SVR)
6 kV, 500 Amp (8 x 20 usec)4
L-N
L-G
N-G
L-L
80 kA
80 kA
330 V
700 V
400 V
600 V
80 kA
80 kA
330 V
700 V
400 V
600 V
80 kA
80 kA
800 V
1,500 V
800 V
1,500 V
80 kA
160 kA
—
1,200 V
—
1,200 V
NOTES:
1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage.
2
All surge currents listed above are independently tested and verified per NEMA LS-1.
3
Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems.
4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition.
Flush Mount Plate PG2-FMP
104
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Surge Suppression System
PG1000 Series
Features
• L-N, N-G protection modes (4 mode)
• Redundant protection per mode
• Integral 200 KAIC fusing and thermal protection
• Thermally protected MOVs for maximum safety
• Fault current tested to 200 KAIC
• EMI/RFI filtration – Up to 54 dB from 20 kHz to 100 MHz
• UL1449, 2nd Edition and UL1283 Listed, cULus
• NEMA 4 style enclosure
• Pre-wired with 30" of #10 AWG wire leads
• Available with flush mount cover PG2-FMP
• 10 year product warranty
• Complementary Listed as Secondary Surge Arrester
(OWHX,E135626)
Integral Diagnostics
• LED indicator lights for each mode
• Form C Contacts
• Audible alarm
Surge Current Capacity
(8 x 20 usec) (per mode)2
Intermatic
MCOV1
Model
L-N
L-N
L-G
N-G
PG1000-240-2S 120/240 VAC Single Phase (split)
115%
40 kA
—
40 kA
PG1000-208-3Y 120/208 VAC Three Phase Wye
115%
40 kA
—
40 kA
PG1000-480-3Y 277/480 VAC Three Phase Wye
115%
40 kA
—
40 kA
PG1000-480-3D 480 VAC Three Phase Delta
115%
—
40 kA
—
Per
Phase3
L-L
UL 1449 Clamping Voltage (SVR)
6 kV, 500 Amp (8 x 20 usec)4
L-N
L-G
N-G
L-L
40 kA
40 kA
330 V
700 V
400 V
600 V
40 kA
40 kA
330 V
700 V
400 V
600 V
40 kA
40 kA
800 V
1,500 V
800 V
1,500 V
40 kA
80 kA
—
1,200 V
—
1,200 V
NOTES:
1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage.
2
All surge currents listed above are independently tested and verified per NEMA LS-1.
3
Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems.
4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition.
40kA
PER
PHASE
The PG1000 Series is a hardwired
suppression device (installed in
parallel) and recommended for all
ANSI/IEEE Category locations.
Dimensions:
11.0"H x 5.875"W x 3.75"D
Weight: 22 lbs.
Flush Mount Plate PG2-FMP
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
105
Modular Protection System
There are four main factors to
consider when specifying the
appropriate device for your facility:
1. What is the amperage (size) of the
Switchboard or Panelboard at the
point of installation?
2. What is the geographic location of
the facility? (i.e. the relative level of
lightning exposure and utility grid
switching activity)
3. What is the density of electronic
equipment and how critical is the
application? (i.e. a 7 x 24 computer
data center would require a higher level
of protection than a retail store)
Product Selection Chart – Modular Models
The following guidelines can be followed for Intermatic products:
Choose Model by Voltage
Location
480 VAC Delta
277/480 VAC Wye
Large Service Entrance 2000 to 4000 Amp
Best
SG320K-480-3D
SG320K-480-3Y
Better
SG240K-480-3D
SG240K-480-3Y
Good
UG40A4803D
UG404803Y
Small Service Entrance Less than 1600 Amp
Best
SG240K-480-3D
SG240K-480-3Y
Better
SG160K-480-3D
SG160K-480-3Y
Good
UG30A4803D
UG30A4803Y
Distribution Panel 1000 to 1600 Amp
Best
SG160K-480-3D
SG160K-480-3Y
Better
UG30A4803D
UG30A4803Y
Good
UG28A4803D
UG28A4803Y
Panelboard 60 to 400 Amp
Best
UG30A4803D
UG30A4803Y
Better
UG28A4803D
UG28A4803Y
120/208 VAC Wye
Refer to Page
SG320K-208-3Y
SG240K-208-3Y
UG40A2083Y
107
108
110
SG240K-208-3Y
SG160K-208-3Y
UG30A2083Y
108
109
111
SG160K-208-3Y
UG30A2083Y
UG28A2083Y
109
111
112
UG30A2083Y
UG28A2083Y
111
112
4. What is the level of transient and
noise producing loads within your
facility? (i.e. a heavy industrial
manufacturing environment or a densely
populated computer data center would
require a higher level of protection)
NOTES:
• Pick appropriate model to match the voltage of your Service
Entrance, Distribution Panel or Panelboard.
• See individual product pages for other available voltages.
• A facility without any Service Entrance protection would
warrant a higher level of protection at downstream locations.
106
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Modular Protection System
SG320 Series
Features
• All mode Protection (L-N, L-G, N-G, L-L)
• Fault Current Tested to 200 KAIC
• EMI/RFI Filtration – Up to 50 dB from 20 kHz to 100 MHz
• Replaceable Modules for low MTTR
• NEMA 12 Enclosure
• 40 kA Brute Force MOVs
• Redundant Protection per mode
• Thermally Protected MOVs for maximum safety
• UL1449, 2nd Edition and UL1283 Listed, UL and cUL
• 5 year product warranty
Installation:
• Recommended installation is with 30-100 Amp breaker
320kA
Integral Diagnostics
• LED Indicator Lights
• Form C Contacts
PER
PHASE
• Audible Alarm
• Digital Surge Counter
Surge Current Capacity
(8 x 20 usec) (per mode)
Per
Phase2
Intermatic
MCOV1
Model
L-G
L-N
L-G
N-G
L-L
SG320K-208-3Y 120/208 VAC Three Phase Wye
115%
160 kA
160 kA
120 kA 160 kA
SG320K-240-3HLD 120/240 VAC Three Phase High Leg Delta
115%
160 kA
160 kA
120 kA 160 kA
SG320K-480-3Y 277/480 VAC Three Phase Wye
115%
160 kA
160 kA
120 kA
SG320K-480-3D 480 VAC Three Phase Delta
115%
—
160 kA
—
UL 1449 Clamping Voltage (SVR)
6 kV, 500 Amp (8 x 20 usec)3
L-N
L-G
N-G
L-L
320 kA
400 V
400 V
700 V
800 V
320 kA
400 V /
(800 V)
400 V /
(800 V)
700 V
800 V
160 kA
320 kA
800 V
800 V
1,500 V
1,500 V
160 kA
320 kA
—
1,500 V
—
2,500 V
NOTES:
1
MCOV is Maximum Continuous Operating Voltage expressed in percent of nominal voltage.
2 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems.
3
Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition.
The SG320 Series is a modular
hardwired suppression device and
recommended for all ANSI/IEEE
Category locations. Contains one
bolt-on module per phase for easy
maintenance.
Dimensions: 16"H x 14"W x 6"D
Weight: 29 lbs.
REPLACEMENT MODULE INFORMATION
System Number:
Quantity & Part Number
SG320K-208-3Y
(3) SG160-120V-M
SG320K-240-3HLD
(2) SG160-120V-M
(1) SG160-240V-M
SG320K-480-34
(3) SG160-277V-M
SG320K-480-3D
(3) SG160-480V-M
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
107
Modular Protection System
SG240 Series
Features
• All mode Protection (L-N, L-G, N-G, L-L)
• Fault Current Tested to 200 KAIC
• EMI/RFI Filtration – Up to 50 dB from 20 kHz to 100 MHz
• Replaceable Modules for low MTTR
• NEMA 12 Enclosure
• 40 kA Brute Force MOVs
• Redundant Protection per mode
• Thermally Protected MOVs for maximum safety
• UL1449, 2nd Edition and UL1283 Listed, UL and cUL
• 5 year product warranty
Installation:
• Recommended installation is with 30-100 Amp breaker
Integral Diagnostics
240kA
• LED Indicator Lights
• Form C Contacts
PER
PHASE
• Audible Alarm
• Digital Surge Counter
Surge Current Capacity
(8 x 20 usec) (per mode)
Per
Phase2
Intermatic
MCOV1
Model
L-G
L-N
L-G
N-G
L-L
SG240K-208-3Y 120/208 VAC Three Phase Wye
115%
120 kA
120 kA
120 kA 120 kA
SG240K-240-3HLD 120/240 VAC Three Phase High Leg Delta
115%
120 kA
120 kA
120 kA 120 kA
SG240K-480-3Y 277/480 VAC Three Phase Wye
115%
120 kA
120 kA
120 kA
SG240K-480-3D 480 VAC Three Phase Delta
115%
—
120 kA
—
The SG240 Series is a modular
hardwired suppression device and
recommended for all ANSI/IEEE
Category locations. Contains one
bolt-on module per phase for easy
maintenance.
Dimensions:
16"H x 14"W x 6"D
Weight: 28 lbs.
UL 1449 Clamping Voltage (SVR)
6 kV, 500 Amp (8 x 20 usec)3
L-N
L-G
N-G
L-L
240 kA
400 V
400 V
700 V
800 V
240 kA
400 V /
(800 V)
400 V /
(800 V)
700 V
800 V
120 kA
240 kA
800 V
800 V
1,500 V
1,500 V
120 kA
240 kA
—
1,500 V
—
2,500 V
NOTES:
1
MCOV is Maximum Continuous Operating Voltage expressed in percent of nominal voltage.
2 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems.
3
Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition.
REPLACEMENT MODULE INFORMATION
System Number:
Quantity & Part Number
SG240K-208-3Y
(3) SG120-120V-M
SG240K-240-3HLD
(2) SG120-120V-M
(1) SG120-240V-M
SG240K-480-34
(3) SG120-277V-M
SG240K-480-3D
(3) SG120-480V-M
108
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Modular Protection System
SG160 Series
Features
• All mode Protection (L-N, L-G, N-G, L-L)
• Fault Current Tested to 200 KAIC
• EMI/RFI Filtration – Up to 50 dB from 20 kHz to 100 MHz
• Replaceable Modules for low MTTR
• NEMA 12 Enclosure
• 40 kA Brute Force MOVs
• Redundant Protection per mode
• Thermally Protected MOVs for maximum safety
• UL1449, 2nd Edition and UL1283 Listed, UL and cUL
• 5 year product warranty
Installation:
• Recommended installation is with 30-100 Amp breaker
Integral Diagnostics
160kA
• LED Indicator Lights
• Form C Contacts
PER
PHASE
• Audible Alarm
• Digital Surge Counter
Surge Current Capacity
(8 x 20 usec) (per mode)
Per
Phase2
Intermatic
MCOV1
Model
L-G
L-N
L-G
N-G
L-L
SG160K-208-3Y 120/208 VAC Three Phase Wye
115%
80 kA
80 kA
120 kA 80 kA
SG160K-240-3HLD 120/240 VAC Three Phase High Leg Delta
115%
80 kA
80 kA
120 kA 80 kA
SG160K-480-3Y 277/480 VAC Three Phase Wye
115%
80 kA
80 kA
120 kA
SG160K-480-3D 480 VAC Three Phase Delta
115%
—
80 kA
—
UL 1449 Clamping Voltage (SVR)
6 kV, 500 Amp (8 x 20 usec)3
L-N
L-G
N-G
L-L
160 kA
400 V
400 V
700 V
800 V
160 kA
400 V /
(800 V)
400 V /
(800 V)
700 V
800 V
80 kA
160 kA
800 V
800 V
1,500 V
1,500 V
80 kA
160 kA
—
1,500 V
—
2,500 V
NOTES:
1
MCOV is Maximum Continuous Operating Voltage expressed in percent of nominal voltage.
2 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems.
3
Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition.
The SG160 Series is a modular
hardwired suppression device and
recommended for all ANSI/IEEE
Category locations. Contains one
bolt-on module per phase for easy
maintenance.
Dimensions: 16"H x 14"W x 6"D
Weight: 27 lbs.
REPLACEMENT MODULE INFORMATION
System Number:
Quantity & Part Number
SG160K-208-3Y
(3) SG80-120V-M
SG160K-240-3HLD
(2) SG80-120V-M
(1) SG80-240V-M
SG160K-480-34
(3) SG80-277V-M
SG160K-480-3D
(3) SG80-480V-M
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
109
Modular Protection System
UG40 Series
90kA
PER
PHASE
Features
• All mode Protection (L-N, L-G, N-G, L-L)
• Integral Disconnect
• Redundant Protection per mode
• Thermally Protected MOVs for maximum safety
• UL1449, 2nd Edition, cULus
• 10 year product warranty
• Fault Current Tested to 200 KAIC
• 200 KAIC Surge Rated Fuses
• EMI/RFI Filtration – 20 to 30 dB from 20 kHz to 100 MHz
• Replaceable Modules for low MTTR
• NEMA 3R Style Enclosure
• Complementary Listed as Secondary Surge Arrester
(OWHX,E135626)
Integral Diagnostics
• LED Indicator Lights
• Audible Alarm
• Intermatic Thermal Monitoring System
• Form C Contacts
Surge Current Capacity
(8 x 20 usec) (per mode)
The UG40 Series is a modular
hardwired suppression device and
recommended for all ANSI/IEEE
Category locations. Contains one
module per phase for easy
maintenance.
Dimensions:
20.75"H x 10.75"W x 4.75"D
Weight: 23 lbs.
REPLACEMENT MODULE INFORMATION
System Number:
Quantity & Part Number
UG40A2401S
(2) UG41120A
UG40A2083Y
(3) UG41120B
UG40A2403D
(2) UG41120A
(1) UG41208A
UG40A2403G
(3) UG41240A
UG40A4803Y
(3) UG41277A
UG40A4803D
(3) UG41480A
110
Per
Phase2
Intermatic
MCOV1
Model
L-G
L-N
L-G
N-G
L-L
UG40A2401S 120/240VAC Single Phase (split)
115%
45 kA
45 kA
90 kA
45 kA
UG40A2083Y 120/208 VAC Three Phase Wye
115%
45 kA
45 kA
135 kA 45 kA
UG40A2403D 120/240 VAC Three Phase High Leg Delta
115%
45 kA
45 kA
135 kA 45 kA
UG40A2403G 240 VAC Three Phase Delta
115%
—
90 kA
—
UG40A4803Y 277/480 VAC Three Phase Wye
115%
45 kA
45 kA
135 kA
UG40A4803D 480 VAC Three Phase Delta
115%
—
90 kA
—
UL 1449 Clamping Voltage (SVR)
6 kV, 500 Amp (8 x 20 usec)3
L-N
L-G
N-G
L-L
90 kA
500 V
500 V
500 V
800 V
90 kA
500 V
500 V
500 V
700 V
90 kA
500 V /
(800 V)
500 V /
(700 V)
500 V
800 V
45 kA
125 kA
—
700 V
—
800 V
45 kA
90 kA
900 V
900 V
800 V
1,500 V
45 kA
135 kA
—
1,500 V
—
1,500 V
NOTES:
1
MCOV is Maximum Continuous Operating Voltage expressed in percent of nominal voltage.
2
Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems.
3
Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition.
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Modular Protection System
90kA
UG30 Series
PER
PHASE
Features
• All mode Protection (L-N, L-G, N-G, L-L)
• Fault Current Tested to 200 KAIC
• 200 KAIC Surge Rated Fuses
• Redundant Protection per mode
• EMI/RFI Filtration – 20 to 30 dB from 20 kHz to 100 MHz
• Complementary Listed as Secondary Surge Arrester (OWHX,E135626)
• Thermally Protected MOVs for maximum safety
• Replaceable Modules for low MTTR
• UL1449, 2nd Edition, cULus
• NEMA 3R Style Enclosure
• 10 year product warranty
Integral Diagnostics
• LED Indicator Lights
• Intermatic Thermal Monitoring System
Surge Current Capacity
(8 x 20 usec) (per mode)
Per
Phase2
Intermatic
MCOV1
Model
L-G
L-N
L-G
N-G
L-L
UG30A2401S 120/240 VAC Single Phase (split)
115%
45 kA
45 kA
90 kA
45 kA
UG30A2083Y 120/208 VAC Three Phase Wye
115%
45 kA
45 kA
135 kA 45 kA
UG30A2403D 120/240 VAC Three Phase High Leg Delta
115%
45 kA
45 kA
135 kA 45 kA
UG30A2403G 240 VAC Three Phase Delta
115%
—
90 kA
—
UG30A4803Y 277/480 VAC Three Phase Wye
115%
45 kA
45 kA
135 kA
UG30A4803D 480 VAC Three Phase Delta
115%
—
90 kA
—
UL 1449 Clamping Voltage (SVR)
6 kV, 500 Amp (8 x 20 usec)3
L-N
L-G
N-G
L-L
90 kA
500 V
500 V
400 V
700 V
90 kA
500 V
500 V
400 V
700 V
90 kA
500 V /
(700 V)
500 V /
(700 V)
400 V
700 V
45 kA
135 kA
—
700 V
—
700 V
45 kA
90 kA
800 V
800 V
800 V
1,500 V
45 kA
135 kA
—
1,500 V
—
1,500 V
The UG30 Series is a modular
hardwired suppression device and
recommended for all ANSI/IEEE
Category locations. Contains one
module per phase for easy
maintenance.
Dimensions:
12.88"H x 10.94"W x 4.65"D
Weight: 15 lbs.
NOTES:
1 MCOV is Maximum Continuous Operating Voltage expressed in percent of nominal voltage.
2
Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems.
3
Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition.
Flush Mount Plate UG1-FMP
REPLACEMENT MODULE INFORMATION
System Number:
Quantity & Part Number
UG30A2401S
(2) UG29120A
UG30A2083Y
(3) UG29120A
UG30A2403D
(2) UG29120A
(1) UG29208A
UG30A2403G
(3) UG29240A
UG30A4803Y
(3) UG29277A
UG30A4803D
(3) UG29480A
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
111
Modular Protection System
UG28 Series
90kA
PER
PHASE
Features
• Nine mode Protection (L-N, L-G, L-L)
• Fault Current Tested to 200 KAIC
• 200 KAIC Surge Rated Fuses
• Redundant Protection per mode
• EMI/RFI Filtration – 20 to 30 dB from 20 kHz to 100 MHz
• Complementary Listed as Secondary Surge Arrester (OWHX,E135626)
• Thermally Protected MOVs for maximum safety
• Replaceable Modules for low MTTR
• UL1449, 2nd Edition, cULus
• NEMA 3R Style Enclosure
• 10 year product warranty
Integral Diagnostics
• LED Indicator Lights
• Intermatic Thermal Monitoring System
The UG28 Series is a modular
hardwired suppression device and
recommended for all ANSI/IEEE
Category locations. Contains one
module per phase for easy
maintenance.
Dimensions:
12.88"H x 10.94"W x 4.65"D
Weight: 15 lbs.
Surge Current Capacity
(8 x 20 usec) (per mode)
Per
Phase2
Intermatic
MCOV1
Model
L-G
L-N
L-G
N-G
L-L
UG28A2401S 120/240 VAC Single Phase (split)
115%
45 kA
45 kA
—
45 kA
UG28A2083Y 120/208 VAC Three Phase Wye
115%
45 kA
45 kA
—
45 kA
UG28A2403D 120/240 VAC Three Phase High Leg Delta
115%
45 kA
45 kA
—
45 kA
UG28A4803Y 277/480 VAC Three Phase Wye
115%
45 kA
45 kA
—
UG28A4803D 480 VAC Three Phase Delta
115%
—
90 kA
—
UL 1449 Clamping Voltage (SVR)
6 kV, 500 Amp (8 x 20 usec)3
L-N
L-G
N-G
L-L
90 kA
500 V
500 V
—
700 V
90 kA
500 V
500 V
—
700 V
90 kA
500 V /
(700 V)
500 V /
(700 V)
—
700 V
45 kA
90 kA
800 V
800 V
—
1,500 V
45 kA
135 kA
—
1,500 V
—
1,500 V
NOTES:
1
MCOV is Maximum Continuous Operating Voltage expressed in percent of nominal voltage.
2 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems.
3
Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition.
Flush Mount Plate UG1-FMP
REPLACEMENT MODULE INFORMATION
System Number:
Quantity & Part Number
UG28A2401S
(2) UG27120A
UG28A2083Y
(3) UG27120A
UG28A2403D
(2) UG27120A
(1) UG27208A
UG28A4803Y
(3) UG27277A
UG28A4803D
(3) UG27480A
112
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Industrial Point-of-Use Protection
F20 Series
Features
• All mode Protection
• Thermally Protected MOVs for maximum safety
• UL1449, 2nd Edition and UL1283 Listed, cULus
• NEMA 4 Enclosure
• EMI/RFI Filtration – 26 to 39 dB
• 5 year product warranty
Integral Diagnostics
• LED Indicator Lights
• Intermatic Thermal Monitoring System
• Form C Contacts
Surge Current Capacity
(8 x 20 usec) (per mode)
Intermatic
MCOV1
Model
L-G
L-N
L-G
IG1201F20 120 VAC Single Phase
115%
16 kA
16 kA
IG2401F20 240 VAC Single Phase
115%
—
32 kA
UL 1449 Clamping Voltage (SVR)
6 kV, 500 Amp (8 x 20 usec)3
N-G
L-L
Per
Phase2
16 kA
—
32 kA
500 V
500 V
500 V
—
—
16 kA
48 kA
—
700 V
—
700 V
L-N
L-G
N-G
L-L
NOTES:
1 MCOV is Maximum Continuous Operating Voltage expressed in percent of nominal voltage.
2
Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems.
3
Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition.
The F20 Series is a hardwired in line
suppression device for protection of
loads up to 20 Amps including fire
alarm circuits, industrial controls,
PLC’s and any other sensitive
electronic equipment.
Dimensions:
4.54"H x 3.5"W x 2.2"D
Weight: 2.5 lbs.
Din Rail Adapter Kit IG1DIN-F20
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
113
Industrial Point-of-Use Protection
Features
A
B
• Designed for heavy industrial use
• 3-mode Surge Protection (L-N, L-G, N-G)
• UL1449, 2nd Edition, cULus
• EMI/RFI noise filtration
A. IG11246
C
• 4-outlets
• 6 ft. cord
• Lighted On/Off switch
B. IG11466
D
• 6-outlets
• 6 ft. cord
• Lighted On/Off switch
• Enhanced EMI/RFI noise filtration, UL1283
F
C. IG11266
E
• 6-outlets
• 6 ft. cord
• Lighted On/Off switch
D. IG11266BLK10
G
• Black
• 6-outlets
• 10 ft. cord
• Lighted On/Off switch
H
I
E. IG2066 & IG20615
• 6 specification-grade outlets
• Master On/Off switch
• Enhanced EMI/RFI noise filtration, UL1283
• 6 ft. cord (IG2066); 15 ft. cord (IG20615)
• 14 gauge SJT power cord with molded plug
• Protection monitoring circuitry with LED light indicator
• 15 amp resettable breaker
• Ivory metal housing
F. IG1866A
• 6-outlets
• 6 ft. cord
• Audible alarm
• Master On/Off switch
• Enhanced EMI/RFI noise filtration, UL1283
G. IG20B12 & IG2012B15
• 6 specification-grade outlets
• Master On/Off switch
• Enhanced EMI/RFI noise filtration, UL1283
• 6 ft. cord (IG20B12); 15 ft. cord (IG2012B15)
H. IG2086
• 8 specification-grade outlets
• Master On/Off switch
• Enhanced EMI/RFI noise filtration, UL1283
• 6 ft. cord
I. IG9638S55
• 6 specification-grade outlets
• Lighted On/Off switch
• Steel housing
• 15 ft. cord
See chart on page 115 for UL1449 ratings and EMI/RFI filtration.
Computer Control Centers
Features
• 6 centralized switches
• One unswitched receptacle
• Metal housing
• Static discharge pad
• 15 Amp, resettable circuit breaker
J. IG141
• Standard model
J
K
L
M
114
• 9 ft., 14 gauge power cord
• LED Indicator Light monitors power on & protection status
• L-N, L-G and N-G surge protection
• cULus
• UL1449, 2nd Edition
L. IG143
• Enhanced EMI/RFI noise attenuation
• Dual choke design for lower clamping
K. IG141T
• Standard model with phone/fax/modem protection
• RJ11 connectors
M. IG143T
• Enhanced model with phone/fax/modem protection
• RJ11 connectors
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Industrial Point-of-Use Protection
Mounting Bracket & Plate
N
N. IG1SRMP
• Allows any IG strip to be mounted on a 19" equipment rack
O. 24EG5133
• Secures mounting bracket for all IG strips in extruded aluminum alloy housing (See models on chart with *)
Product Selection Chart – Point of Use Models
Energy Capacity
UL1449
Clamping
Number
Max.
Max.
Connected Voltage (SVR)
Intermatic
of
Cord Electrical Joule.
Surge. Equipment 6 kV, 500A
Model
Outlets Length Rating
Rating Amperage $ Coverage (8 x 20 μ sec)
Industrial Grade
L-N/L-G/N-G
IG11246*
4
6
120 V/15 A 480
24,000 A
$10,000
400/400/400
IG11266*
6
6
120 V/15 A 480
24,000 A
$10,000
400/400/400
IG11266BLK10*
6
10
120 V/15 A 480
24,000 A
$10,000
400/400/400
IG11466*
6
6
120 V/15 A 480
24,000 A
$10,000
400/400/400
IG1866A*
6
6
120 V/15 A 960
48,000 A
$25,000
330/330/330
IG2066*
6
6
120 V/15 A 960
48,000 A
$25,000
330/330/330
IG20615*
6
15
120 V/15 A 960
48,000 A
$25,000
330/330/330
IG20B12*
6
6
120 V/15 A 480
24,000 A
$ 5,000
400/400/400
IG2012B15*
6
15
120 V/15 A 480
24,000 A
$ 5,000
400/400/400
IG9638S55
6
15
120 V/15 A 480
24,000 A
—
400/400/400
IG2086*
8
6
120 V/15 A 960
48,000 A
$25,000
330/330/330
Computer Control Centers
IG141
6
9
120 V/15 A 480
24,000 A
$10,000
400/400/400
IG141T
6
9
120 V/15 A 480
24,000 A
$10,000
400/400/400
IG143
6
9
120 V/15 A 960
48,000 A
$25,000
330/330/330
IG143T
6
9
120 V/15 A 960
48,000 A
$25,000
330/330/330
EMI-RFI Noise
Filtration
Prod.
Frequency Max. Warr.
Range (Hz) Reduc. (yrs)
100k-20M
100k-20M
100k-20M
100k-20M
100k-100M
100k-100M
100k-100M
100k-20M
100k-20M
100k-20M
100k-100M
25dB
25dB
25dB
40dB
62dB
62dB
62dB
25dB
25dB
21dB
62dB
5
5
5
5
5
5
5
5
5
5
5
100k-20M
100k-20M
100k-100M
100k-100M
25dB
25dB
62dB
62dB
5
5
5
5
O
* = Extruded aluminum housing
NOTE: Cord lengths can be modified up to 25 feet. Consult Factory for pricing and availability.
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
115
Residential Hardwired Protection
IG Series
Features
• Hardwired models provide greater capacity to handle surge energy (based on their close location to the service ground) compared to
standard plug-in strips
• Designed for 120/240 volt single or (split-phase) panels
• Dual LED indicator(s) provides surge protection status on AC
A
A. IG1300-2T-1C
• 120/240 VAC Single (Split) Phase
• 6 Modes of Surge Protection (L1-N, L2-N, L1-G, L2-G, N-G, L1-L2)
• Provides protection for 2 Telephone Lines (Analog Phone Line, Modem, or DSL) and 1 Coax Line
(Cable TV, Cable Internet or Satellite TV)
• UL 1449 Listed, 2nd Edition and UL497A Listed, cULus
• NEMA 3R Raintight Enclosure for indoor or outdoor installations (9.38"H x 5.25"W x 4.0"D)
• Tested to 65 kAIC per NEC Section 285
• 5 Year Product Warranty
• $10,000 Connected Equipment Coverage
• Complementary Listed as Secondary Surge Arrester (OWHX,E135626)
B
B. IG1300-4T-2C
• 120/240 VAC Single (Split) Phase
• 6 Modes of Surge Protection (L1-N, L2-N, L1-G, L2-G, N-G, L1-L2)
• Provides protection for 4 Telephone Lines (Analog Phone Line, Modem, or DSL) and 2 Coax Lines
(Cable TV, Cable Internet or Satellite TV)
• UL 1449 Listed, 2nd Edition and UL497A Listed, cULus
• NEMA 3R Raintight Enclosure for indoor or outdoor installations (9.38"H x 5.25"W x 4.0"D)
• Tested to 65 kAIC per NEC Section 285
• 5 Year Product Warranty
• $10,000 Connected Equipment Warranty (Appliances and Electronics) [5 year]
• Complementary Listed as Secondary Surge Arrester (OWHX,E135626)
C
C. IG1240RC
D
• 120/240 VAC Single (Split) phase
• 6 Modes of Surge Protection (L1-N, L2-N, L1-G, L2-G, N-G, L1-L2)
• Green LED indicator provides status of protection; Red LED indicator indicates reduced protection
• NEMA 4 plastic housing (5.65"H x 4.18"W x 3.33"D)
• 5 year product warranty
• UL Listed UL1449, 2nd edition, cULus
• Tested to 65 kAIC per NEC Section 285
• $10,000 Connected Equipment Coverage (Appliances and Electronics) [5 year]
• Complementary Listed as Secondary Surge Arrester (OWHX,E135626)
IG1240FMP3
• Includes faceplate, screws and mounting bracket for IG1240RC
D. IG3240RC
Flush Mount Plates
IG1240FMP3
IG3240FMP3
• 120/240 VAC Single (Split) phase
• 6 Modes of Surge Protection (L1-N, L2-N, L1-G, L2-G, N-G, L1-L2)
• Green LED indicator provides status of protection; Red LED indicator indicates reduced protection
• NEMA 4 metal housing (6.28"H x 4.4"W x 3.25"D)
• 10 year product warranty
• UL Listed UL1449, 2nd edition, cULus
• Tested to 65 kAIC per NEC Section 285
• $25,000 Connected Equipment Coverage (Appliances and Electronics) [5 year]
• Complementary Listed as Secondary Surge Arrester (OWHX,E135626)
IG3240FMP3
• Includes faceplate, screws and mounting bracket for IG3240RC
116
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Residential Hardwired Protection
E. IG251
E
• Handles up to 600 Amp service capacity
• Enclosure size (6.0"H x 3.5"W x 3.0"D)
• Epoxy encapsulation protects surge components from moisture, dirt and corrosion
• 5 year product warranty
• UL 1449 2nd edition listed as a Transient Voltage Surge Suppressor
• 250 Volt MCOV for generator applications
Intermatic
Model
Service
Voltage
Phase
IG1300-2T-1C
IG1300-4T-2C
IG1240RC
IG3240RC
IG251
120/240
120/240
120/240
120/240
120/240
2
2
2
2
2
Leads
# – Length
4
4
4
4
4
24
24
30
30
24
Gauge
Wire
Config.
Peak Surge
Current
Per Phase/
System
14
14
14
14
12
L1, L2, N, GND
L1, L2, N, GND
L1, L2, N, GND
L1, L2, N, GND
L1, L2, N, GND
20 kA/60 kA
20 kA/60 kA
20 kA/60 kA
60 kA/180 kA
48 kA/115 kA
UL 1449 Clamping
Voltage (SVR)
6 kV, 500 Amp
(8 x 20 μ sec)
L-N L-G N-G L-L
400
400
400
330
600
400
400
400
330
—
400
400
400
330
—
700
700
700
600
1200
F
Stand Alone Telephone / Modem / DSL Internet Lines
F. IG2TM
• Provides protection for 2 lines
• Tip to Ground, Tip to Ring and Ring to Ground Modes
• 40 kA surge protection per line
• Gas Tube Protection 350 Volt DC Breakdown
• UL497A
• Nema 1 Type Enclosure
Model Number
IG2TM
Application
Lines
Gauge
Wire Configuration
phone/modem/DSL
up to 2
#24-#16 AWG
4 wire
DC
Breakdown
Voltage Application
350 Vdc
G
Indoor
G. IG4TM
• Protection same as IG2TM
• Protects 4 Lines
Model Number
IG4TM
Application
Lines
Gauge
phone/modem/DSL
up to 4
#24-#16 AWG
DC
Breakdown
Wire Configuration
Voltage Application
8 wire
350 Vdc
Indoor
H. IG2T3R
• Protection same as IG2TM
• Provides protection for 2 lines (expandable to 12 Lines)
• Nema 3R Type Enclosure
Model Number
IG2T3R
Application
phone/modem/DSL
Lines
Gauge
H
DC
Breakdown
Wire Configuration
Voltage Application
2 standard #24-#16 AWG 4 wire (up to 24 wire)
(up to 12)
350 Vdc Indoor/Outdoor
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
117
Residential Hardwired Protection
I
Stand Alone Local Antenna/Cable - Satellite/Cable Internet Protection
I. IG1CM
• Provides Protection for 1 Line (Expandable to 2 Lines)
• 10 kA surge protection per line
• Gas Tube Protection 90 Volt DC Breakdown
Application
Lines
Thread Type
DC
Breakdown
Voltage
Cable TV/internet/satellite
1
F
90 Vdc
Application
Indoor/Outdoor
Model Number
IG1CM
J
Application
Indoor
J. IG1C3R
• Protection same as IG1CM
• Provides Protection for 1 Line (Expandable to up to 6 Coax Lines)
• Nema 3R Type Enclosure
Model Number
IG1C3R
Application
Lines
Thread Type
DC
Breakdown
Voltage
Cable TV/internet/satellite
1 Standard (up to 6)
F
90 Vdc
K. IG2T
• Spare Telephone / Modem / DSL Internet Protection Module
K
Model Number
IG2T Spare
Lines
2
For Use In:
IG2TM, IG1CM, IG2T3R, IG1C3R, IG1300-2T-1C
L. IG1C
• Spare Coax Cable Protection Module
Model Number
IG1C Spare
L
Lines
1
For Use In:
IG1CM, IG1C3R, IG2TM, IG4TM, IG2T3R
M. IGFlush Mount Kit
• Flush mount kit for IG2TM, IG4TM, and IG1CM
Model Number
IG Flush Mount Kit
For Use In:
IG2TM IG4TM, IG1CM
M
118
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Surge Arresters
A
Features:
• Designed for outdoor installations on service entrance and utility meter cabinets
• Approved for outdoor applications such as irrigation equipment, pumps, lighting fixtures, traffic signaling devices, farm equipment,
HVAC controls and motors
• Parallel metal oxide varistors (MOV) from each line to grounded neutral provide increased product capability
• Molded polycarbonate housing with 1/2" x 20 threaded nipple is weatherproof and UV resistant
• Epoxy encapsulation protects components from moisture, dirt and corrosion
• Color coded 18" leads
• UL listed as a secondary surge arrester, ANSI/IEEE C62.11 for Category “C” locations “OWHX”
• 2 year product warranty
A. AG2401C
• 120/240 single phase, 2 pole 3 wire device
• 18" 14 gauge leads
B. AG2083C
• 120/208 VAC, 3 pole 4 wire device
• 18" 12 gauge leads
C
• Up to 600 V three phase, 3 pole 4 wire device
• 18" 12 gauge leads (AG6503); 36" 10 gauge leads
(AG6503L)
D
E
G. AG2401C-IND
• 120/240 single phase, 2 pole 3 wire device
• 18" 14 gauge leads
D. AG4803C
• 277/480 VAC or 480 VAC, 3 pole 4 wire device
• 18" 12 gauge leads
Service Voltage
AG6503L
• 277V or 480V VAC single phase, 2 pole 3 wire device
• 18" 10 gauge leads
• 18" 6 gauge green ground lead
• 240 VAC, 3 pole 4 wire device
• 18" 12 gauge leads
Standard (No LED’s)
AG2401C
120/240V
AG2083C
208V
AG2403C
240V
AG4801
277V or 480V
AG4803C
480V
AG6503C
Up to 600V
AG6503L
Up to 600V
Enhanced (with LED‘s)
AG2401C-IND
120/240V
AG6503C-IND Up to 600V
B
F. AG4801
C. AG2403C
Model
E. AG6503C &
H. AG6503C-IND
• Up to 600 V three phase 3 pole 4 wire device
• 18" 12 gauge leads
Poles
Number of Leads/
Length
Wire
Configuration
1 or 2
3
3
1 or 2
3
3
3
3/18"
4/18"
4/18"
3/18"
4/18"
4/18"
4/36"
L1, L2, GND/N
L1, L2, L3, GND/N
L1, L2, L3, GND/N
L1, L2, GND
L1, L2, L3, GND/N
L1, L2, L3, GND/N
L1, L2, L3, GND/N
1500A
490
490
740
1450
1450
1640
1640
5000A
980
980
1330
2130
2130
2340
2340
10000A
1410
1410
1850
2620
2620
2920
2920
1 or 2
3
3/18"
4/18"
L1, L2, GND/N
L1, L2, L3, GND/N
490
1640
980
2340
1410
2920
F
Actual Clamping Voltage
(Line to Ground)
Match the correct model to the voltage of your system/machine
G
H
The chart below shows Typical Clamp Voltage for each model.
Mounting Bracket
AG1BRKT
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
119
Surge Arresters
A. UG240R
B. IG250LA
• 120/240 V Surge Arrester for up to 600 Amp service
• 2 pole 3 wire configuration for installation on utility
cabinets and outdoor service panels
• Enclosure size (6.0"H x 3.5"W x 3.0"D)
• Steel weatherproof housing with lockable cover
• Epoxy encapsulation protects components from moisture,
dirt and corrosion
• UL listed as a Secondary Surge Arrester (OWHX)
• LED indicator provides surge protection status
• 5 year product warranty
A
B
• 120/240 V Surge Arrester for up to 600 Amp service
• Designed for applications frequently subjected to high
level surge energy
• Enclosure size (6.63"H x 3.75"W x 2.5"D)
• Epoxy encapsulation protects components from moisture,
dirt and corrosion
• UL listed as a Secondary Surge Arrester (OWHX)
• LED indicator provides surge protection status
• 5 year product warranty
Number
Peak Surge Current
of 24"
Wire
Per Phase/
Leads Configuration
Per System
Model
Service
Voltage Phase
UG240R
120/240
2
3
L1, L2, N
48 kA/115 kA
IG250LA
120/240
2
3
L1, L2, N
48 kA/115 kA
Clamping
Voltage
@500A
Enclosure
Size
(inches)
Weight
Lbs
L-N: 555
L-L 1028
L-N: 555
L-L: 1028
6.06 x 3.81 x 3.31
2.4
6.0 x 3.5 x 3.0
2.4
Surge Protection Device Connected Equipment Coverage
Surge Protection devices, with Connected
Equipment Coverage, offers the user extended
Product Type
Metal Multi-Outlet Strip
Page #
114
Model Number
IG2012B15
IG20B12
Metal Multi-Outlet Strip
Computer Control Center
Residential Grade Protector
114
114
116
117
118
114
114
114
116
IG11246
IG141
IG1240RC
IG2TM
IG1CM
IG1866A
IG2066
IG143
IG3240RC
protection for sensitive equipment. In the
unlikely event that a damaging transient surge
passes through the surge device and damage
occurs to the connected equipment, Intermatic
Metal Multi-Outlet Strip
Computer Control Center
Residential Grade Protector
IG11266
IG141T
IG1300-2T-1C
IG4TM
IG1C3R
IG2046
IG2086
IG143T
Maximum Repair or
Replacement Coverage
IG11466
IG1300-4T-2C
IG2T3R
will pay up to $25,000 to repair or replace the
equipment based on the specified model and
coverage provided. Refer to the warranty
document included with the product for specific
coverage details and
limitations.
120
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
CONSUME
R
S
T
C
U
D
O
PR
121
Entering a New Century of Energy
Management and Home Security!
Indoor and Outdoor Timers
Intermatic offers a wide variety of styles
to meet today’s application
requirements.
Intermatic timers add convenience by
turning lights ON when needed, and
saves energy by turning lights OFF when
not needed. They give homes a lived-in
look providing an easy and economical
way to improve home security.
Outdoor timers also let users control
outside lights and holiday displays while
staying comfortably inside.
Heavy Duty
Outdoor Timers
for lights, motors
& pool pumps
Digital Photo
Control
automatically
turns lights on
at dusk, off
6 hours later
Do-it-yourself
Wireless
Motion
Sensor
Alarms
Home
Controls,
Modules and
controllers
Power Failure Lights & Photo
Controls
Intermatic power failure lights have
many practical applications in the home:
in bedrooms, hallways, stairways,
bathrooms, kitchens and more.
Photo controls are a simple solution to
turning lights on when dark, off when
light.
Do-it-Yourself Security Alarms
The Burglary Prevention Council
statistics show that residential break-ins
occur every 11 seconds.
Intermatic answers the demand for
easy-to-install, affordable security
products with a full line of DIY portable
security alarms that have superior
features.
Intermatic Wireless Alarms provide
economical home security. There are no
monthly fees or setup charges. The
wireless feature offers easy do-ityourself installation at affordable prices.
122
Outdoor Digital
Timers with light
sensor to control
outdoor lights &
holiday displays
Heavy-Duty
Digital 7-Day
Wall Switch
Timers to control
fans, lights &
appliances with
“never set it
again” feature
All purpose
Heavy-Duty
Lamp &
Appliance
Timers
24 Hr. Heavy-Duty
Programmable
Digital Timer for
lamps, stereos, &
appliances
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Intermatic Home Controls
A
Until now, the ability to reliably and cost efficiently control lighting and electronics and electrical devices in
the home, using Radio Frequency, was extremely limited. Intermatic introduces a line of cost effective plug-in
modules, in-wall receptacles and switches and easy-to-use controllers that allow fingertip control of multiple
items in and around the house. Intermatic’s Home Controls incorporate Z-Wave™ technology – the most
advanced, low cost and highly efficient Radio Frequency based technology in the industry.
Innovative Features:
• All items are controlled by Radio Frequency (no wiring is involved)
• Easy DIY installation
• All products use unique Z-Wave™ technology
• Two-way feedback lets you know if the system is properly set up and if the system is working properly
• The cost for this highly reliable system is priced much less than comparable systems that require contractor installation
• All modules and in-wall products can be set for timing control
• Each module includes a “repeater” function, for unmatched reliability
• Controllers can control up to 192 devices and can create “scenes” to create the light level look wanted
A. HA01C Wall Receptacle
• Replaces standard wall receptacles
• One receptacle is controlled
• LED shows feedback from controller during setup and
that the controlled device is working
• Use with decora wall plate (not included)
Specifications:
• For indoor use only
• 15 Amps Resistive
• 8.3 Amps Tungsten
• 120VAC, 60 Hz
• Temperature operating range: 0°C to 60°C
B. HA02C Plug-In Appliance Module
• Controls appliances up to 15 Amps and lighting
(including compact fluorescent bulbs)
• Heavy-duty 3 prong plug and receptacle
• Manual override
• LED shows feedback from controller during setup and
that the controlled device is working
Specifications:
• For indoor use only
• 15 Amps Resistive
• 1200 W Inductive
• 1/2 HP
• 8.3 Amps Tungsten
• 120VAC, 60 Hz
• Temperature operating range: 0°C to 60°C
B
C. HA03C Plug-In Indoor Lamp
Module
• Controls ON/OFF/DIM for incandescent lamps
• Manual override
• LED shows feedback from controller during setup and
that the controlled device is working
C
Specifications:
• For indoor use only
• 300 Watts
• 120VAC, 60 Hz
• Temperature operating range: 0°C to 60°C
D
D. HA04C Outdoor Lighting Module
• Controls ON/OFF outdoor devices
• Weather resistant
• 6" cord
• Manual override
• LED shows feedback from controller during setup and
that the controlled device is working
Specifications:
• 15 Amp Resistive
• 1/2 HP
• 1200 W Inductive
• 8.3 Amp Tungsten
• 120 VAC, 60 Hz
• Temperature operating range: -35°C to 60°C
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
123
Intermatic Home Controls
E
E. HA05C Outdoor Lamp Screw-In
Module
• For incandescent and PAR lamps
• Fits most outdoor fixtures
• ON/OFF functions
• Manual override
• LED shows feedback from controller during setup and
that the controlled device is working
Specifications:
F
• 300 W Tungsten, 4 W compact fluorescent
• 120 VAC, 60 Hz
• Temperature operating range: -35° C to 60° C
F.
HAO6C Indoor Wall Switch
• Rocker style uses decorative wall plate (not included)
• ON/OFF/DIM controls
• Manual override
• LED shows feedback from controller
during setup and that the controlled
device is working
Specifications:
G
• For indoor use only
• 300 Watts Tungsten
• 120 VAC, 60 Hz
• Temperature operating range: 0°C to 70°C
G. HA07 Master Remote Controller
• Controls all Intermatic Home Settings devices
• Large LCD screen shows all functions when set-up is
successful, dim levels, channels and time functions
• Easy to set up
• Attractive design can be set on a table or wall mounted
• ALL ON/ALL OFF buttons controls devices to warn
would-be intruders
• Controls up to 12 channels
• Each channel can control up to 16 devices
• Timing controls for all devices include:
- Set the Astronomic feature and you will never have to
reset the timer for the everyday changes in SUNRISE
and SUNSET times.
- Multiple time options: all week, 5 days, weekends or
individual days
- RANDOM timing option for a “lived-in” look
- Optional automatic Daylight Savings Time function
• 8 dimming levels
• Requires 4 AA batteries (not included).
Specifications:
• Temperature operating range: 0°C to 60°C
H. HA09C Handy Remote Control
• Controls all Intermatic Home Controls devices
• Easy to set up
• Attractive, easy to hold
• Controls up to 6 channels
• Each channel can control up to 16 devices
• 8 dimming levels
• Requires 4 AAA batteries (not included)
Specifications:
• Temperature operating range: 0°C to 60°C
H
124
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Indoor Plug-In Timers
Heavy Duty Lamp & Appliance Timers
A. TN111C
Lamp & Appliance Timer
D. TN711C
Random Pattern Security Timer
• 2 ON / 2 OFF settings per day
• Controls lamps & appliances
• Ideal for all-purpose use
• Ratings: 15 Amp Resistive, 1750 Watts Tungsten, 1/3 HP,
125 VAC, 60 Hz
B. TN111GC
Lamp & Appliance Timer With
Lighted Dial
• 2 on/2 off settings per day
• Turns lights on and off automatically within ±15 min. of
the set times
• Eliminates the predictable “timer-controlled” look
• Ratings: 15 Amp Resistive, 1750 Watts Tungsten, 1/3 HP,
125 VAC, 60 Hz
E. TN311C
Heavy-Duty Grounded Timer
Override switch
with on/off
indicator faces
up - easiest to
view and change
Oversized
color-coded
trippers simplest to
use
• 3 on/3 off settings per day
• For air conditioners, heaters and other heavy electrical
loads
• Ratings: 15 Amp Resistive, 1750 Watts Tungsten &
Resistive, 125 VAC, 60 Hz, 12 FLA, 72 LRA, 120 VAC
Motor (12 AMP Air Conditioner)
• Transparent plastic dial acts as a night light
• 2 ON / 2 OFF settings per day
• Ideal for all-purpose use
• Ratings: 15 Amp Resistive, 1750 Watts Tungsten, 1/3 HP,
125 VAC, 60 Hz
Unique “time
of day”
window quickest and
easiest to set
B
A
C. TN811C
Multi-Setting Timer
C
• 24 ON / 24 OFF settings per day
• Convenient programmable settings
• Enhances safety & security by making home look more
“lived-in”
• Ratings: 15 Amp Resistive, 1750 Watts Tungsten, 1/3 HP,
125 VAC, 60 Hz
D
E
Digital Plug-in Timers
F.
DT17C
7-Day Heavy-Duty Digital Timer
• Up to 14 ON / 14 OFF settings per day or 98 ON / 98
OFF settings per week
• Random setting option avoids predictable “timercontrolled” look
• 3-prong grounded plug and receptacle
• Controls lamps (including fluorescent), TVs, stereos and
appliances
• Easy-to-set hand-held programming with battery backup
• Manual override feature
• Ratings: 15 Amp Resistive & Inductive, 500 Watts
Tungsten, 1/3 HP 120 VAC
H. DT27C
Heavy-Duty Digital Timer with
Astronomic Feature
• Up to 7 ON/OFF settings per day
• Astronomic features allow setting it once without ever
having to reset it again; follows daily changes in
sunrise/sunset times
• Random setting option avoids predictable “timercontrolled” look
• 3-prong grounded plug and receptacle
• Controls lamps (including fluorescent), TVs, stereos and
appliances
• Easy to program
• Battery backup
• Manual override feature
• 15 Amp Resistive and Inductive, 500 Watts Tungsten, 1/3
HP, 120 VAC, 60 Hz
G. DT121C
Digital Lamp Timer
• 2 ON / 2 OFF settings per day
• Controls indoor lamps
• To-the-minute accuracy
• Large display, easy to read
• Manual override feature
• Ratings: 8.3 Amp Resistive and Inductive, 300 Watts
Tungsten, 120 VAC, 60 Hz
I.
F
G
TB121C
Digital Table Top Timer
• 2 ON / 2 OFF settings per day
• Attractive tabletop styling in decorative platinum
• 5 ft. cord
• Easy to reach
• Large display, easy to read
• To-the-minute accuracy
• Manual override feature
• Ratings: 8.3 Amp Resistive and Inductive, 300 Watts
Tungsten, 120 VAC, 60 Hz
H
I
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
125
Appliance & Wall Switch Timers
Heavy Duty Appliance Timers
A. HB112C
Air Conditioner &
Appliance Timer
C. HB113C
Air Conditioner &
Appliance Timer
Same as HB112C except
2500W/120V/
for the following:
1 H.P. 120V Max.
• Automatically controls 120 Volt Motor Load
air conditioners, heaters,
heavy-duty appliances
and lamps
• 2,500 Watt capacity
• Automatically controls 240 volt 3750W/240V/
air conditioners, heaters,
2 H.P. 240V Max.
heavy-duty appliances
Motor Load
and lamps
• 3,750 watt capacity
• Plugs directly into wall outlet
• 2 ON/2 OFF settings per day
• 3-prong 220-240 Volt grounded plug and receptacle
• Manual override ON/OFF switch
A,
B,
C
D
B. HB114C
Air Conditioner &
Appliance Timer
E
• Same as HB112C except for
the following:
• 5,000 Watt capacity
5000W/240V/
2 H.P. 240V Max.
Motor Load
Wall Switch Timers
D. ST01C
Heavy Duty In-Wall Timer with
Astronomic Feature
Can be used with four separate programming options:
Same settings Monday through Friday, Saturday & Sunday,
all 7 days of the week or individual daily settings.
F
G
H
• DST for 2006, 2007 and flexible for future changes, if
needed
• Set it once and never set it again; follows daily changes
in sunrise/sunset times
• For single pole and three way applications up to 100 ft.
• Controls lighting including fluorescent and heavy duty
loads such as fans and appliances
• Up to 6 ON/OFF settings per 7-day period a total of 42
ON/42 OFF settings per week
• Easy-to-set 6 button programming
• LCD digital clock and readout
• To-the-minute setting accuracy
• Battery backup
• Random setting feature available to avoid predictable
“timer controlled” look
• Manual override feature
• Use with decorator-style wall plate (not included)
• Ratings:
Resistive: 15 A, 120-277 VAC
Tungsten: 15 A, 120 VAC, 6 A, 208-277 VAC
Ballast: 8 A, 120 VAC, 4 A, 208-277 VAC
Motor: 1 HP, 120 VAC, 2 HP, 240 VAC
DC Loads: 4 A, 12 VDS, 2 A, 28 VDS
E. ST01AC
Heavy Duty In-Wall Timer with
Astronomic Feature
F.
EJ351C
Programmable 24-hour
Security Timer
• Up to 24 ON/24 OFF settings per day
• Random setting turns light ON and OFF at slightly
different times each day
• Self-learning feature: if not manually programmed, it will
repeat the first 24 hr. ON/OFF pattern
• 15 minute memory guard protects against power failure
• Replaces any standard wall light switch
• Use with existing wall plate; standard (toggle) or
decorator (rocker) styles
• Ratings: 500 Watts Incandescent, 120 VAC, 60 Hz
G. EJ500C
Indoor Digital Wall Switch Timer
with Astronomic Feature
• Flushmount design
• 6 ON/6 OFF settings per day
• Controls incandescent and fluorescent (class “P” ballast)
lighting
• Easy to set programming
• Set it once and never set it again; follows daily changes
in sunrise/sunset times
• Battery backup guards against memory loss
• Replaces any standard wall switch
• Use with decorative style wall plate(not included)
• Ratings: 500 Watts Incandescent, 120 VAC, 60 Hz
H. EJ500AC
Indoor Digital Wall Switch Timer
with Astronomic Feature
Same as EJ500C except Almond Color
Same as ST01C except Almond color
126
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Outdoor Timers
A. HB31R
Heavy Duty Outdoor Timer
(15 Amp)
C. HB51RC
Outdoor Timer with Light Sensor
• Highly versatile control with choice of operating modes
• Photo ON / Timer OFF mode provides automatic ON at
dusk, OFF after owner’s choice on 2, 4, 6 or 8 hours
• Photo ON / Photo OFF mode offers automatic ON at
dusk, OFF at dawn
• 8.3 Amp lighting timer
• Manual override ON/OFF switch
• Grounded, compact 6" cord
• Up to 2 ON / 2 OFF settings per day
• Full 15 Amp capacity controls lighting and heavy-duty
loads such as motors and pool pumps
• Grounded plug
• Manual override ON/OFF switch
• Waterproof cover
• Heavy-duty 12" grounded cord
• 120 VAC, 60 Hz
B. HB35R
Outdoor Timer (10 Amp)
D. HB61RC
Digital Outdoor Timer with
Light Sensor
• 2 ON / 2 OFF settings per day
• Grounded plug
• Manual override ON/OFF switch
• Waterproof cover
• Heavy-duty 15" cord
• 120 VAC, 60 Hz
• Photo ON at dusk, OFF at dawn
• Photo ON at dusk, OFF at 1 hour increments from 1-9
hours
• Immediate ON/OFF at owner’s selection in 1 hour
increments for 1-9 hours
• Manual override
• Grounded 6" cord and receptacle
Model
Number
Max. ON
Time
Min. ON
Time
HB31R
23-1/2 hrs.
1/2 hr.
HB35R
23-1/2 hrs.
1/2 hr.
HB51RC
Dusk to 8 hr.
Dusk to 2 hr.
HB61RC
Dusk to 8 hr.
Dusk to 2 hr.
A
B
Capacity
15 Amps, 1800 Watts Resistive; 15 Amps, 1800 Watts Tungsten,
15 FLA, 90 LRA; 120 VAC Operating Temp.: -40˚C to +40˚C
10 Amps, 1200 Watts Resistive; 10 Amps, 1200 Watts Tungsten;
120 VAC Operating Temp.: -40˚C to +40˚C
8.3 Amps, 1000 Watts Resistive; 8.3 Amps, 1000 Watts Tungsten,
120 VAC Operating Temp.: -35˚C to +40˚C
8.3 Amps, 1000 Watts Resistive; 8.3 Amps, 1000 Watts Tungsten,
120 VAC Operating Temp.: -35˚C to +40˚C
C
D
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
127
Outdoor Timers
E
E. HB77R
Digital Outdoor Timer
G. HB88RC
Programmable Outdoor Timer
• 15 Amp capacity controls lighting and heavy-duty loads
such as motors and pool pumps
• 14 ON / OFF settings per day - a total of 42 ON / OFF
settings per week - can be used with 4 separate
programming options
– Same settings Monday through Friday
– Same settings Saturday and Sunday
– Same settings all 7 days of the week
– Various daily settings
• Easy hand-held programming
• Replaceable button cell batteries (included) maintains
program, during power failure
F.
• 15 Amp capacity controls lighting and heavy duty loads
such as engine block heaters, holiday and landscape
lighting, pool/spa pumps and more
• 7 day / 7 event programming
• Multiple daily programming options
– Same settings Monday through Friday
– Same settings Saturday and Sunday
– Same settings all 7 days of the week
– Individual daily settings
• Two timed receptacles
• Battery backup
• Ratings: 15 Amp Resistive and Tungsten, 1000W
Inductive, 1/2 HP, 120 VAC, 60 Hz
HB1116R
6 Outlet Electromechanical Timer
with Stake
• 2 ON/OFF settings per day
• Full 15 Amp capacity controls lighting and heavy loads
such as motors, engine block heaters and pool pumps
• Weatherproof cover
• 24" grounded cord
• Grounded receptacle
• Circuit breaker
• Manual override ON/OFF switch
• For wall mounting or stake mounting
F
Model
Number
Max. ON
Time
Min. ON
Time
HB77R
6 days
23 hrs. 59 min.
23-1/2 hrs.
1 min.
6 days
23 hrs. 59 min.
1 min.
HB1116R
HB88RC
1/2 hr.
Capacity
15 Amps Resistive and Inductive, 500 Watts Tungsten, 1/3 H.P.,
120 VAC Operating Temp.: -35˚C to +40˚C
15 Amps, 1800 Watts Resistive; 15 Amps 1800 Watts Tungsten
15 FLA, 90 LRA, 120 VAC Operating Temp.: -40˚C to +40˚C
15 Amps, 1000 Watts Resistive; 15 Amps 1000 Watts Tungsten
1/2 HP; 120 VAC; 60 Hz
G
128
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Photo Controls
Power Failure Light
Safety Light Products
A. NE1C
Screw-In Photo Control
D. NE200C
Plug-In Photo Control
• Automatically turns electrical load ON at dusk, OFF at
dawn
• Screws into any standard incandescent light socket
• Controls interior and exterior lights
B. NE2C
Automatic Security Light Dual
Photo Cell with Flicker Eliminator
• Automatically turns electrical load ON at dusk, OFF at
dawn
• Advanced technology circuit saves energy
• Screws into any standard incandescent light socket
• Controls interior and exterior lights
C. NE3BC
Digital Photo Control,
Time Controlled
• Automatically turns electrical load ON at dusk, OFF at
dawn
• For outdoor spot and flood lamps, used on driveways
and patios
• Also ideal for indoor or outdoor PL lamp fixtures
(compact fluorescent)
B
E. NE250C
Outdoor Photo Control
• Automatically turns electrical load ON at dusk, OFF at
dawn
• For outdoor spot and flood lamps, used on driveways
and patios
• Handles up to 150 Watt incandescent bulbs
F.
• Automatically turns light ON at dusk and OFF 6 hours
later
• Soft start extends bulb life
• Controls incandescent lights up to 150 Watts
• Screw into any standard incandescent light socket
• Controls indoor and exterior lights
• Handles up to 150 Watt incandescent and 45 Watt
fluorescent bulbs
A
C
NE5C
Plug-In Photo Control
• Automatically turns electrical load ON at dusk, OFF at
dawn
• Plugs into any polarized indoor wall socket
• Controls indoor devices such as table light, floor light,
radio or TV
E
D
F
Power Failure Light
G. PR3C
3-in-1 Power Failure Light
• Light automatically comes on when power goes out
• Automatic guide light
• Can be used as a handy rechargeable flashlight
• Screw-off cover with replaceable #14 flashlight bulb
• Plugs into any polarized indoor wall socket
• Provides safety and security
• Unique receptacle for plugging in additional lamp or
appliance
• 120 Volts, 60 Hz, 1 Watt
G
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
129
Intermatic Do-It-Yourself Security
Security Alarms
A
A. SP230B
Wireless Alarm with Motion Sensor
• Place on wall, table or shelf
• Piercing alarm activated when movement is detected
• Warning sticker included
• Programmable code entered on keypad
activates/deactivates alarm
• 110 dB siren
B. SP130B
Wireless Door Alarm with
Programmable Keypad
B
• Piercing alarm activated when contact point is broken
• Mounts on door
• Code entered on keypad activates/deactivates alarm
• 110 dB siren
C. SP440B
Wireless Window Alarm
• Piercing alarm activated when contact point is broken
• Mounts on window
• ON/OFF switch activates/deactivates alarm
• 90 dB siren
D. SP500
Window Stickers
• Discourages intruders
• 4 pack
E. SP640B
Personal Security Alarm
• Piercing alarm sounds when pin is removed
• Small enough to hold in the palm of the hand
• Alerts others that help is required
• Includes flashlight and belt clip
• 90 dB siren
C
E
D
130
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Malibu Low Voltage Landscape Lighting
®
Malibu®, the leading landscape lighting brand, has been making lighting systems to enhance the beauty, safety
and security of American homes for almost 40 years. In that time we’ve learned a lot about how American
consumers use their outdoor space, and we’ve seen the definition of “outdoor lifestyle” grow. People spend
more time outdoors than ever before, and it’s important to them to decorate their outdoor space. Malibu® helps
them make their outdoors as beautiful, livable and enjoyable as their indoors.
Fixtures For Every Need
The traditional approaches to outdoor lighting are to provide uplight, to highlight trees or bushes and create
a focal point for beauty; downlight to place along walkways and steps or outline driveways for safety; and
backlight to illuminate walls or fences and light up a home’s exterior for security. To fill these needs, Malibu®
offers a wide variety of floodlights and decorative fixtures, path and garden lights. Traditional lighting
approaches are still very relevant today, but the trend that expands gracious living to a home’s outdoor space
has led to a new approach, the creation of outdoor decorative elements that provide function and beauty in the
daytime, as well as illumination at night. These items include an illuminated birdbath, lighthouse and rock
spotlights.
Lighting the way to outdoor living
12 volt fixtures provide
important benefits not
available with conventional
110 volt systems
• Fast, easy installation
• Flexibility to add and adjust fixtures as landscape
matures
• Economical operation, thanks to longer lamp life &
less energy usage
• No hard wiring required
• No need for junction box on each fixture
• Maximum eye appeal both night (when on) & day
Market Leading Power Packs and Accessories
(when off)
Malibu® high quality Power Packs offer dependable power and integrated Intermatic timers to ensure that your
customers’ landscape lighting delivers bright reliable light in any weather, year in and year out. Malibu® bulbs
and cable complete the picture to give you safe, weather-resistant installations.
®
Malibu Products are Affordable and Guaranteed
Malibu® is committed to building the best products available across several price ranges. We also offer one
of the most comprehensive warranties in the industry; from 3 years to lifetime depending on the fixture, and 5
years on Power Packs.
For more information and to view the most up-to-date listing of Malibu® Landscape Lighting products, see
our Landscape Lighting catalog, or visit our web site at www.intermatic.com.
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
131
Malibu Low Voltage Landscape Lighting
®
132
CS110P
CS110TA
CS120TA
CS14P
Metal Walk Light with
11W wedge base
bulb and Pewter
finish
Metal Walk Light with
11W wedge base bulb
and Architectural
Bronze finish
Metal Walk Light with
18W wedge base bulb
and Architectural
Bronze finish
Metal Carriage Light
with 11W wedge base
bulb and Pewter
finish
CS17K
CS140K
CS180C
CS200C
Metal Mission Light
with 11W wedge base
bulb and Antique
Copper finish
Metal Lantern Light
with 18W wedge base
bulb and Antique
Copper finish
Copper Floodlight
with 20W halogen
MR16 bulb
Copper Tier Light
with 18W wedge base
bulb
CS230R
CS240
CS330OB
CS508K
Metal Mission Light
with 18W wedge base
bulb and Aged Brass
finish
Metal Parfait Light
with 18W wedge base
bulb and Aged Brass
finish
Metal Walk Light with
11W wedge base bulb
and Oiled Bronze finish
Metal floodlight with
35W halogen MR16
bulb and Antique
Copper finish
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Malibu Low Voltage Landscape Lighting
®
CS508P
CS508S
CS508TA
CS7AC1
Metal floodlight with
35W halogen MR16
bulb and Pewter
finish
Metal floodlight with
35W halogen MR16
bulb and Sand finish
Metal floodlight with
35W halogen MR16
bulb and Architectural
Bronze finish
Metal garden light
with 11W wedge base
bulb and Antique
Copper and Oil
Rubbed bronze finish
CS7CT4
CS7E1
NA320
NA401
Metal garden light
with 4W wedge base
bulb and Black finish
Metal garden light
with 4W wedge base
bulb and Black finish
Natural Rock Light
with 20W MR11 bulb
Metal Birdbath Light
with 35 watt MR16
bulb and Verdigris
finish
NA501
Metal Hanging Floral
Basket Light with 7 watt
wedge base bulb and
Verde finish
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
133
Malibu Low Voltage Landscape Lighting
®
Finishes & Colors
Choose from classic or contemporary
designs in a variety of finishes and
textures. Use Malibu® fixtures to blend
into your landscape design, add an
elegant touch to a garden path or
highlight architecture for safety and
security.
Aged Brass
Antique Copper
(K)
Architectural Bronze
(TA)
Black Chrome
(BC)
Black Satin Bronze
(BSB)
Brushed Nickel
(N)
Copper
(C)
Graphite
(GR)
Oil Rubbed Bronze
(OB)
Pewter
(P)
Rustic Brick
(RB)
Sand
(S)
Verde
(V)
Verde Patina
(V)
CL1
CL111R
CL115
CL191
Metal floodlight with
50W halogen MR16
bulb and Black finish
Well Light with 11W
Poly-Star bulb and
Black finish
Submersible Light
with 20W halogen
MR16 bulb and Black
finish
Metal Tier Light with
11W wedge base bulb
and Black finish
CL191K
CL191S
CL191V
CL280
Metal Tier Light with
11W wedge base bulb
and Antique Copper
finish
Metal Tier Light with
11W wedge base bulb
and Sand finish
Metal Tier Light with
11W wedge base bulb
and Verde finish
Metal Tulip Light with
18W wedge base bulb
and Black finish
CL305P
CL4
CL501
CL503TA
Metal Walk Light with
11 watt wedge base
bulb and Pewter finish
Metal Hanging
Lantern with 7W
wedge base bulb and
Black finish
Metal Well Uplight with
35 watt MR16 bulb and
Black finish
Metal Surface Light
with 7 watt wedge
base bulb and
Architectural Bronze
finish
Verdigris
Due to Intermatic’s dedication to technological advancement,
it is possible that specifications and/or appearances of our
products may have changed after the printing of this literature.
See price list for the latest available product light sets.
134
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Malibu Low Voltage Landscape Lighting
®
CL507
CL508
CL509
CL635R
Metal Floodlight with
20W halogen MR16
bulb and Black finish
Metal Floodlight with
35W halogen MR16
bulb and Black finish
Metal Wall Wash
Floodlight with 20W
halogen bi-pin bulb
and Black finish
Metal Bollard Light
with 20W MR11 bulb
and Black Finish
CL635P
CL635RS
CL635RK
CL711
Metal Bollard Light with
20W MR11 bulb and
Pewter finish
Metal Bollard Light
with 20W MR11 bulb
and Sand finish
Metal Bollard Light with
20W MR11 bulb and
Antique Copper finish
Metal Mushroom
Light with 10W
halogen bi-pin bulb
and Black finish
CL801BC8
CL802BSB6
CL802P7
CL803S2
Metal garden light with
4 and 11W wedge base
bulbs, Black Chrome
finish and Frosted
Crackel Glass Globe
Metal garden light with
4 and 11W wedge base
bulbs, Black Satin
Bronze finish and
Mocha Marble Glass
Globe
Metal garden light with
4 and 11W wedge base
bulbs, Pewter finish and
Square Frosted Glass
Globe
Metal garden light
with 4 and 11W
wedge base bulbs,
Sand finish and
Frosted Ribbed Glass
Globe
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
135
Malibu Low Voltage Landscape Lighting
®
136
CL8041
CL9
CL9S
CL905
Metal garden light with
4 and 11W wedge base
bulbs, Black finish and
Alabaster-Style Glass
Globe
Metal Floodlight with
20W halogen bi-pin
bulb and Black finish
Metal Floodlight with
20W halogen bi-pin
bulb and Sand finish
Metal Half Brick Light
with 7W wedge base
bulb and Black finish
CL905K
LT8
LT8K
LT9
Metal Half Brick Light
with 7W wedge base
bulb and Antique
Copper finish
Metal Surface Light
with 7W wedge base
bulb and Black finish
Metal Surface Light
with 7W wedge base
bulb and Antique
Copper finish
Metal Floodlight with
10W halogen bi-pin
bulb and Black finish
LT10
LT13
LT13N
LT13S
Metal Shaded Flare
Light with 11W
wedge base bulb and
Black finish
Metal Three Tier Light
with 7W wedge base
bulb and Black finish
Metal Three Tier Light
with 7W wedge base
bulb and Nickel finish
Metal Three Tier Light
with 7W wedge base
bulb and Sand finish
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Malibu Low Voltage Landscape Lighting
®
LT406
LT406N
Metal Two Tier Light
with 4W wedge base
bulb and Black finish
Metal Two Tier Light
with 4W wedge base
bulb and Nickel finish
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
137
Malibu Low Voltage Landscape Lighting
®
Power Packs
Low Voltage Polymer
Intermatic offers the widest variety of Power Packs in any wattage and control option your system may require.
Power Packs are available from 44 to 900 watts, allowing you to choose which power supply is right for your
particular lighting plan.
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
LD622L/ML60721 LV181/ML10781
Plastic Deck Light
4W wedge base bulb
All Power Packs are certified for safe operation and long life. Keyhole mountings are featured for ease of
operation and installation. See chart below for available Power Packs and features.
Plastic Tier Light
7W wedge base bulb
Models
Max. Wattage Output
Specifications
LV103/ML91103
LV108/ML90708
ML44T
ML60TW
ML88T
ML100T
ML121RT
ML200RT
ML200RTW
ML300RTW
ML600TW
ML900TW
44 Watt
60 Watt
88 Watt
100 Watt
121 Watt
200 Watt
200 Watt
300 Watt
600 Watt
900 Watt
Timer with 2 sets of trippers
Timer with 2 sets of trippers and ground shield
Timer with 2 sets of trippers
Timer with 2 sets of trippers
Timer with 2 sets of trippers
Timer with 2 sets of trippers
Timer with 2 sets of trippers and ground shield
Timer with 2 sets of trippers and ground shield
Timer with 2 sets of trippers and ground shield
Timer with 2 sets of trippers and ground shield
Plastic Floodlight
11W wedge base bulb
Plastic Floodlight
7W wedge base bulb
IMPORTANT: When planning your lighting and choosing a Power Pack, your total bulb wattage must not exceed maximum transformer wattage
output rating.
Power PackModels
LV183/ML11183
LD641/ML60704
Plastic Tier Light
11W wedge base bulb
Plastic Deck Light
7W wedge base bulb
yyy yyyyyyyy yyyyyyyy
yyy
yyyy
yyyy
yyyy
yyy
yyyy
yyyy
yyyy
yyyy
yyyy
yy
yyyy
yyyy
yyyy
yyyy
yyyy
yy
yyyy
yyyy
yyyy
yyyy
yyyy
yy
yyyy
yyyy
yyyy
yyyy
yyyy
yy
yyyy
yyyy
yyyy
yyyy
yyyy
yy
yyyy
yyyy
yyyyyyy
yyyy
yyyy
yyyyyyyy
yyyy
yyyyyyyy
yyyy
yyyyyyyy
yyy
yyyyyyyy
yyyy
yyy
yyyy
yyyy
yyyy
yyyy
yyy
yyyy
yyyy
yyyy
yyyy
yyyy
yy
yyyy
yyyy
yyyy
yyyy
yyyy
yy
yyyy
yyyy
yyyy
yyyy
yyyy
yy
yyyy
yyyy
yyyy
yyyy
yyyy
yy
yyyy
yyyy
yyyy
yyyy
yyyy
yy
yyyy
yyyy
yyyyyyy
yyyy
yyyy
yyyyyyyy
yyyy
yyyyyyyy
yyyy
yyyyyyyy
yyy
yyyyyyyy
yyyy
yyy
yyyy
yyyy
yyyy
yyyy
yyy
yyyy
yyyy
yyyy
yyyy
yy
yyyyyyyy
yyyy
yyyy
yyyy
yyyy
yy
yyyy
yyyy
yyyyyyyy
yyyy
yy
yyyy
yyyy
yyyyyyy
yyyy
yyyyyyyy
yyyyyyyy
yyyyyyyy
yyyy
yyyyyyyyyyyy
yyyyyyy
LX9Z/ML90401
LX1/ML10401
Plastic Floodlight
4W wedge base bulb
Plastic Tier Light
4W wedge base bulb
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
ML44T
ML60TW
ML88T
ML100T
ML121RT
ML200RT
ML200RTW
ML300RTW
ML600TW
ML900TW
Low Voltage Cable
For fast, easy installation of Malibu® light
fixtures, use low voltage cable. It’s safe,
weather-resistant, self sealing and available
in 16, 14 and 12 gauge sizes.
LD622/ML60722
Plastic Deck Light
4W wedge base bulb
138
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Malibu Solar-Powered Accent Lighting
®
Solar accent lighting is the simplest and safest way to brighten your home’s walkways, decorate patios and
flower beds or create an enchanting lake view. Solar powered light fixtures cost nothing to operate and each
fixture automatically recharges during the day and turns on at dusk. Malibu solar accent lights utilize the
latest in L.E.D. technology to create lights that are brighter and stay lit longer than other
solar-powered brands. Choose from our new brighter white L.E.D. light fixtures or from our more traditional
amber colored L.E.D. fixtures. Each fixture contains a scientifically designed solar collector panel that converts
sunlight into electrical energy. With no plug-in receptacles or power packs, solar accent lights can be installed
even in remote areas where the sun shines and regular power sources aren’t available. Malibu solar lights
operate independently, allowing you to use as many as you like.
Premium Metal Walk Light
LZ7CT4
LZ7FC4
LZ7Z6
LZ51GR
Metal Contemporary
Walk Light with White
L.E.D.
Metal French Country
Walk Light with White
L.E.D.
Premium Cast Metal
Zen style Walk Light
with White L.E.D.
Metal French Lantern
with White L.E.D.,
Graphite Finish
LZ191
LZ305P
LZ601
LZ602
Cast Metal Tier Light
with White L.E.D.
Metal Lantern with
Graphite Finish and
White L.E.D.
Copper finish
Metal Pillar-Style
Walklight with White
L.E.D. and Pewter
finish.
Metal Diamond
Mission Light with
Aged Brass Finish and
White L.E.D.
LZ603
LZ11101OB
LZ11101P
LZ11101RB
Metal Pagoda Light
with Black Finish and
White L.E.D.
Metal Walklight with
White L.E.D. and Oil
Bronze finish.
Metal Walklight with
White L.E.D. and
Pewter finish.
Metal Walklight with
White L.E.D. and
Rustic Brick finish.
LZ191K
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
139
Malibu Solar-Powered Accent Lighting
®
Understanding Solar-Powered
Accent Lighting
Solar lights are not for every lighting
application. Malibu Solar Lights produce
a glow that is ideal for outlining
locations and darkened areas such as
steps, walks, etc. Solar Lights are
perfect for for those applications where a
regular power source is unavailable,
where some sort of accent light is
desired and where the area has exposure
to the full daylight sun. Malibu Solar
Lights can be installed just about
anywhere; as long as there is enough
sunlight available to recharge the
batteries. The specially designed solar
panel collects natural sunlight and
converts it into electrical power that is
stored in highly efficient, rechargeable
batteries. Be sure all Solar collector
panels are installed in a sunny location
where they will receive adequate,
unobstructed sunlight each day. Solar
Light performance will be diminished
during cloudy, rainy, or wintery weather
conditions. With fully charged batteries,
Solar Lights will provide many hours of
nighttime illumination.
LZ11101V
LZ11771H
LZ11771HK
LZ14001H
Metal Walklight with
White L.E.D. and
Verde finish.
Metal Prairie Style
Light with White L.E.D.
and Architectural
Bronze finish.
Metal Prairie Style
Light with White L.E.D.
and Antique
Copper finish.
Metal Lantern Light
with White L.E.D. and
Black finish.
LZ14001HP
Pewter finish.
LZ21811K
LZ25030RB
LZ230
Metal Fence Post Light
with White L.E.D. and
Antique Copper finish.
Small Metal Prairie
style Lantern with
Amber L.E.D. and
Rustic Brick finish.
Metal Mission Light
with White L.E.D. and
Aged Brass finish.
LZ25030V
Verde finish.
Metal Walk Lights
LZ406
LZ407
LZ418
LZ422WBR
Metal Tier Light with
Amber L.E.D.
Metal Tier Light with
White L.E.D. and
Pewter finish.
Metal Walklight with
Oil Rubbed Bronze
Finish, White L.E.D..
Dark Brown Walklight
with White L.E.D..
LZ422W
Black Walklight with
White L.E.D..
140
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Malibu Solar-Powered Accent Lighting
®
LZ10130
LZ10131
LZ10131P
Metal Tier Light with
Amber L.E.D..
Metal Tier Light with
White L.E.D..
Metal Tier Light with
White L.E.D. and
Pewter finish.
LZ1
LZ1W
LZ3
LZ4H
Plastic Tier Light with
Amber L.E.D..
Plastic Tier Light with
White L.E.D..
Plastic Contemporary
Solar Fixture with
Amber L.E.D.
Plastic Hanging
Carriage Light with
Amber L.E.D.
LZ3W
LZ4HW
White L.E.D.
White L.E.D.
Plastic Walk Lights
LZ4HWGR
White L.E.D. with
Graphite finish.
LZ4M
LZ4MOB
LZ6
LZ302
Plastic Carriage Light
with White L.E.D. and
Black finish.
Plastic Carriage Light
with White L.E.D. and
Rubbed Bronze finish.
Table Top Accent Light
with Amber L.E.D.
Plastic Post Top Light
with White L.E.D.
LZ4MK
Antique Copper finish.
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
141
Malibu Solar-Powered Accent Lighting
®
LZ312
LZ701/LZ701W
LZ702/LZ702W
LZ703/LZ703W
Path Marker Light with
White L.E.D.
Plastic Walklight with
White or Amber L.E.D.
and Brown finish.
Plastic Walklight with
White or Amber L.E.D.
and Black finish.
Plastic Walklight with
White or Amber L.E.D.
and Black finish.
LZ704/LZ704W
LZ705/LZ705W
LZ20601P
Plastic Walklight with
White or Amber L.E.D.
and Brown finish.
Plastic Walklight with
White or Amber L.E.D.
and Black finish.
Plastic Coach Light
with White L.E.D. and
Pewter finish.
LZ413
LZ413RP4
LZ414
LZ415
Plastic Flood Light Set
with Remote Panel and
3 White L.E.D.s per
Lamp
Plastic Flood Light Set
with 4 Lamps, 3 White
L.E.D.s per lamp
Plastic Flood Light Set
with Remote Panel and
3 White L.E.D.s per
Lamp
Flood Light with 3
White L.E.D.s
Solar Flood Lights
142
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Malibu Solar-Powered Accent Lighting
®
LZ419
LZ605RP
Resin Flood Light with
3 White L.E.D.s
Metal Flood Light with
12 White L.E.D.s, Black
Finish
Specialty Solar Lights
LZ303RB
LZ305FP
LZ310
LZ314
Metal Hanging Lantern
with White L.E.D. and
Rustic Brick finish.
Metal Pillar-Style
Walklight with White
Flickering L.E.D.s and
Pewter finish.
Cast Metal Lamp-Post
Replacement Fixture
with 1 Watt White
L.E.D.
Address Light with
Amber L.E.D.
LZ511A,B,C,R
LZ604B
LZ706
LZ16220
Driveway Markers with
Steady ON or Flash
Modes
Solar Island Torch with
Flickering Amber
L.E.D.s
Resin Pagoda Light
with Amber L.E.D. and
Natural finish.
Plastic Deck Light with
Amber L.E.D.
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
143
Malibu Solar-Powered Accent Lighting
®
LZ90004
LZ16551
LZB1
Replacement Batteries
Plastic Floating Light
with White L.E.D.
Plastic Solar Luminary
with Amber L.E.D
Novelty Solar lights
LZ1WU
Replacement Bulb
LZ306
LZ307
LZ308
LZ313
Decorative Frog Light
with White L.E.D.
Large Turtle with White
L.E.D.
Decorative Lighthouse
with Amber L.E.D.
Turtle with Amber
L.E.D.
Kits
LZ15004
Nickel Metal Hydride replacements
144
LZ13RP4
LZ53RP4
LZ280RP4
Metal Tier Light Set
with 2 White L.E.D.s
per Lamp and Remote
Panel, Black Finish
Metal Deck Light Set
with 2 White L.E.D.s
per Lamp and Remote
Panel, Oil Rubbed
Bronze Finish
Metal Tulip Set with 2
White L.E.D.s per
Lamp and Remote
Panel, Oil Rubbed
Bronze Finish
LZ635RP4
LZ501RP4
Metal Bollard Set with
2 White L.E.D.s per
Lamp and Remote
Panel, Black Finish
Metal Walk Light Set
with 2 White L.E.D.s
per Lamp and Remote
Panel, Oil Rubbed
Bronze Finish
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Malibu Outdoor Living
®
Mosquito Sentinel 360
ACCESSORIES
MZ951
Mosquito Sentinel 360 Octenol Lure
MZ952
MZ501
Mosquito Sentinel 360 Replacement Nets
Trap
• Attracts and kills mosquitoes in your yard
• Provides 360º protection against mosquitoes
up to 1/2 acre
• Uses safe low-voltage power - No propane
cylinders to refill
MZ953
Mosquito Sentinel 360 Replacement Bulbs
MZ105
MZ904
MZ204G
MZ301
• Repels Mosquitoes up to 400 Sq. Ft.
• Patented chemical developed at University
of Florida
MZ101
MZ102
MZ902
• Blocks Mosquitoes up to 100 square feet!
Patented Inhibitor blocks mosquito’s ability
to track your scent.
• Easy to Use
• Long Lasting
• Inhibitor refill lasts up to 3 weeks.
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
145
Cross Reference
Time Switch Motors
Model
(Series)
to be used
Description
UPC*
Item #
Part #
MOTOR ONLY OLD STYLE T100
T100, T170
24V 60Hz
N/A
T100R201,
125V 50Hz
N/A
T1400BR,
125V 60Hz
WG430-10D
T1800BR,
208/277V 50Hz
WG434-20D§
T180, T500,
208/277V 60Hz
WG433-20D
WH10,30,
480V 60Hz
WG436-20
WH40,70,80
MOTOR ONLY NEW STYLE T100
T100, T170
24V 60Hz
CW1570-10D
T180,
125V 60Hz
WG1570-10D
T100R201,
125V 50Hz
WG1571-10D
T100R301,
208/277V 50Hz
WG1574-10D
WH10,30,
208/277V 60Hz
WG1573-10D
WH40,70,80
480V 60Hz
WG1576-10D
MOTOR ONLY T100CR
T100CR,
24V 60Hz
N/A
T170CR,
125V 50Hz
WG1381-10§
T1400BCR,
125V 60Hz
WG1380-11§
T1800BCR
208/277V 50Hz
N/A
208/277V 60Hz
WG1383-11§
480V 60Hz
N/A
MOTOR AND CARRYOVER COMBINED T100CR
T100CR,
24V 60Hz
N/A
T170CR,
125V 50Hz
131T93GA
T1400BCR,
125V 60Hz
131T68GA
T1800BCR
208/277V 50Hz
131T70GA
208/277V 60Hz
131T69GA
480V 60Hz
N/A
MOTOR ONLY
AT1300R
24V 60Hz
N/A
125V 50Hz
N/A
125V 60Hz
WG430-20D
208/277V 50Hz
WG434-20§
208/277V 60Hz
WG433-20D
480V 60Hz
WG436-20
Malibu Repl.
125V 60Hz
WG630D
Motors
125V 60Hz
WG1750-10§
125V 60Hz
N/A
MOTOR ONLY
T1900,
24V 60Hz
N/A
T8800,
125V 50Hz
N/A
R8800
125V 60Hz
WG730-14D
208/277V 50Hz
N/A
208/277V 60Hz
WG733-14D
480V 60Hz
WG736-14D
MOTOR ONLY
T7400B
24V 60Hz
N/A
T7800B
125V 50Hz
N/A
125V 60Hz
WG1600-11
208/277V 50Hz
N/A
208/277V 60Hz
WG1603-11D
480V 60Hz
WG1606-11§
11972 6
11978*
11976 5
11979*
10828 8
11915 4
11919 2
11932 1
02012 2
11938 3
11903*
11902*
11904*
60090
21170
60091
21180
02009 2
11978*
02010 8
11979*
02013*
11911*
12001*
12005 1
12008 2
11939 0
11951 2
11948 2
Model
(Series)
to be used
Description
Part #
MOTOR ONLY
T7400BC
24V 60Hz
N/A
T7800BC
125V 50Hz
WG1381-10§
125V 60Hz
WG1380-11
208/277V 50Hz
N/A
208/277V 60Hz
WG1383-11
480V 60Hz
N/A
MOTOR AND CARRYOVER COMBINED
T7400BC
24V 60Hz
N/A
T7800BC
125V 50Hz
131T93GA
125V 60Hz
131T68GA§
208/277V 50Hz
N/A
208/277V 60Hz
131T69GA
480V 60Hz
N/A
MOTOR AND CARRYOVER COMBINED
V41079CR
24V 60Hz
N/A
V45000
125V 50Hz
131T93GA
V46100C
125V 60Hz
131T68GA§
208/277V 50Hz
N/A
208/277V 60Hz
131T69GA
480V 60Hz
N/A
MOTOR ONLY
V45400
24V 60Hz
N/A
V46400
125V 50Hz
WG1381-10§
125V 60Hz
WG1380-11§
208/277V 50Hz
N/A
208/277V 60Hz
WG1383-11§
480V 60Hz
N/A
MOTOR ONLY
T2000
24V 60Hz
CW720-10§
125V 50Hz
N/A
125V 60Hz
WG720-10D
208/277V 50Hz
WG724-10§
208/277V 60Hz
WG723-10D§
480V 60Hz
N/A
MOTOR ONLY
V47000
24V 60Hz
N/A
V48000
125V 50Hz
N/A
V49000
125V 60Hz
WG690-10
208/277V 50Hz
N/A
208/277V 60Hz
N/A
480V 60Hz
N/A
MOTOR ONLY
LS7000
24V 60Hz
CW190-10D
125V 50Hz
WG191-10§
125V 60Hz
WG190-15D
208/277V 50Hz
WG194-10§
208/277V 60Hz
N/A
480V 60Hz
N/A
MOTOR ONLY
E1000
24V 60Hz
N/A
125V 50Hz
N/A
125V 60Hz
WG230-13D
208/277V 50Hz
N/A
208/277V 60Hz
WG233-18§
480V 60Hz
N/A
UPC*
Item #
11903*
11902 4
11905 5
60090
21170
21180
60090
21170
21180
11903*
11900*
11904*
10846*
11997 0
12000*
11999 4
11991*
10839 4
11957*
11956 7
11960*
Model
(Series)
to be used
Description
MOTOR ONLY
C8815
24V 60Hz
125V 50Hz
125V 60Hz
208/277V 50Hz
208/277V 60Hz
480V 60Hz
MOTOR ONLY
C8825
24V 60Hz
125V 50Hz
125V 60Hz
208/277V 50Hz
208/277V 60Hz
480V 60Hz
MOTOR ONLY
C8835
24V 60Hz
125V 50Hz
125V 60Hz
208/277V 50Hz
208/277V 60Hz
480V 60Hz
MOTOR ONLY
C8845
24V 60Hz
125V 50Hz
125V 60Hz
208/277V 50Hz
208/277V 60Hz
480V 60Hz
MOTOR ONLY
C8855
24V 60Hz
125V 50Hz
125V 60Hz
208/277V 50Hz
208/277V 60Hz
480V 60Hz
MOTOR ONLY
C8865
24V 60Hz
125V 50Hz
125V 60Hz
208/277V 50Hz
208/277V 60Hz
480V 60Hz
MOTOR ONLY
C8866
24V 60Hz
125V 50Hz
125V 60Hz
208/277V 50Hz
208/277V 60Hz
480V 60Hz
Part #
N/A
N/A
WG790-11D
N/A
N/A
N/A
N/A
N/A
WG760-10
N/A
N/A
N/A
N/A
N/A
WG780-12D
N/A
N/A
N/A
N/A
N/A
WG750-10D
N/A
N/A
N/A
N/A
N/A
WG800-11D
N/A
N/A
N/A
CW770-10§
N/A
WG770-10D
N/A
WG773-10
N/A
CW770-10§
N/A
WG770-10
WG774-10
WG773-10
N/A
UPC*
Item #
12019 8
12011*
12017 4
12010 5
10854 7
10852*
12013 6
12014*
10852*
12012*
12015*
12014*
N/A Not available.
11966 6
60037
All time switch motors are available in voltage and cycle shown in 2nd
column. For example: To order new style T100 Series Motor in 60Hz
125V, order WG1570-10D.
NOTE: Carryover only sold as a complete unit with motor. **These
voltages and corresponding motor numbers apply to all model
numbers.
§ Available while supplies last.
Internal revisions may result in the motor you receive having a
different dash number (WG430-3 vs. WG430-10) than the motor
ordered. This revision has no effect on the motor function.
146
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Cross Reference
24-Hour Time Switches
INTERMATIC
Paragon
Specialty Time Switches
Tork
24 Hour Time Switches (1 hour minimum “ON’’ time)
T101
4001-00
1101/1191
T102
4002-71
1102
T103
4003-00
1103/1962
T104
4004-71, 4004-20
1104/1962
T105
4005-00S
3121
T101B
4001-00V
—
T101R
4011-00
1101-0/1191-0
T102R
4012-20
—
T103R
4013-00
1103-0/1962-0
T104R
4014-71, 4014-20
1104-0
T106R
—
—
24 Hour Time Switches with Skip-A-Day
(1 hour minimum “ON’’ time)
T171
P101S
7100
T172
—
7102
T173
4003-00S, P103S
7200
T174
4004-71S, P104S
7202
T175
4005-00S
7120
T176
4006-71S
7122
T171R
4013-00S
7100-0
T172R
4014-20S
7102-0
T173R
4013-00S
7200-0
T174R
4014-20S, 4014-71S
7202-0
T176R
—
7122-0
T1471BR
47017-0S
7300
T1472BR
47017-20S
7302
T1475BR
—
—
T1871BR
—
7220
24 Hour Time Switches with Skip-A-Day and
Carryover 1 hour minimum ‘’ON’’ time
T1471BCR
47217-00S
7300L/7300L-0
T171CR
—
—
T173CR
4213-0S
7200L
T174CR
4114-27S
7202L
Water Heater Time Switches with manual
“external override’’
WH40
—
WH2
INTERMATIC
Paragon
Special Timing Cycle
Tork
Irrigation Time Switches (12 minute minimum “ON’’ time)
T8805P101C
—
—
R8806P101C
—
—
Cycle Time Switches (5 minute-4 hour dial)
C8815
—
8121
C8835
—
8301
C8845
—
—
C8855
—
8061
C8865
—
8601
C8866
—
8602
Lighting Control Centers (7 day dial)
T51211BC
—
T920L
T51311BC
—
T930L
Swimming Pool Time Switches
INTERMATIC
Paragon
24 Hour Time Switches in Plastic Case
T101P
4011-00P
T102P
—
T103P
4013-00P
T104P
4014-71P
24 Hour Time Switches w/ Heater Circuit
T101R201
41011-00
T104R201
41014-20
T101P201
41011-00M
T104P201
41014-20M
2 in 1 24 Hour Time Switches
T10101R
4912-99
T10404R
4918-99
T12404R
4928-99
Tork
1101-N
—
1103-N
1104-N
—
1104FM
—
—
INTERMATIC
Paragon
Tork
24 Hour Time Switches 15 minute minimum “ON’’ time
T1905
1015-00RS
8001
T1905R
42011-00
—
T1906
1015-00RS
8004
T1975
1015-00RS
8007
T1976
1015-00RS
8008
T1975E
1015-40TS
8001-U
Signal Timers
ET279C
25001-0S
—
ET279C
25002-0S
—
ET279C
23001-00S
5701/5702
ET279C
23002-20S
—
ET279C
23002-00S
—
24 Hour Switching (with adjustable 10-60 min.) “ON’’ times
T185
8025-00
4277
Momentary Contact Time Switches (with dry contacts for
low voltage remote and mechanically held contactor
control)
ET279C
47016-00S
1847A
ET279C
47216-00S
1847AL
ET279C
—
1847AW
ET279C
7216-00
1847AWL
7-Day Time Switches
INTERMATIC
Paragon
Tork
1101D
1104D
1104DF
T7401B
T7402B
T7801B
T7802B
T7401BC
T7402BC
T7801BC
7007-00
7007-20, 7007-71
7008-00
7008-20, 7008-71
7217-00
7217-20
7218-00
W100/W200/ W300/W400
W202/W302/W402
W120/W220
W222
W300L/W400L
W302L/W402L
W220L
Astronomic Time Switches
INTERMATIC
Paragon
Tork
Astro Dial
V45471R
V45472R
V45471CR
V45472CR
In-Wall Timers
4003SZ,47017-00S & 00SZ
47017-71S & 71SZ
47217-00SZ
47217-20SZ & 27SZ
7200Z/7300Z
7202Z/7302Z
7200ZL/7300ZL
7202ZL/7302ZL
INTERMATIC
Grasslin
Paragon
Tork
24-Hour Electro-Mechanical In-Wall Timers
E1010
—
—
E1020/E1120
KM2 ST-16
701A/701AC
E1221
—
701A-2G
E1220
KM2 ST-2G
—
24 Hour Electronic In-Wall Timers
EJ351C
ETC-502
—
EJ353C
ETC-503
—
EI500C
—
—
—
WB101
WB103
WB103
—
—
—
Digital In-Wall Timers
INTERMATIC
Paragon
Interval Timers – Electronic
EI15MH
E500/ET2000/ET1100
EI200
—
EI210
—
EI220
—
EI230
—
Tork
—
—
—
—
—
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
147
Cross Reference
Spring Wound Timers
INTERMATIC†
M.H. Rhodes
Mark Time
Tork††
Paragon†††
FF5M/FD5M
FF15M/FD15M
FF30M/FD30M
FF60M/FD60M
FF2H/FD2H
FF4H/FD4H
FF6H/FD6H
FF12H/FD12H
FF5MH
FF15MH/FD15MH
FF30MH/FD30MH
FF60MH/FD60MH
FF6HH/FD6HH
FF12HH/FD12HH
90004/9305M
90005/9315M
90006/9330M
90008/9360M
90281/9302H
90240/9304H
90007/9306H
90001/9312H
90030
90539/9315MH
90032/9330MH
90024/9360MH
90017/9306HH
90015/9312HH
A505M
A515M
A530M
A560M
A502H
A504H
A506H
A512H
–––
A515MH
A530MH
A560MH
A506HH
A512HH
SW5M/SWD5M
SW15M/SWD15M
SW30M/SWD30M
SW60M/SWD60M
SW2H/SWD2H
SW4H/SWD4H
SW6H/SWD6H
SW12H/SWD12H
SW5MH
SW15MH/SWD15MH
SW30MH/SWD30MH
SW60MH/SWD60MH
SW6HH/SWD6HH
SW12HH/SWD12HH
INTERMATIC†
M.H. Rhodes
*SPDT (for reverse action applications)
FF32HH
9302HH
FF34HH
9304HH
FF36H/FD36H
–––
FF312H
–––
FF315M
90012
FF330M
90011
FF360M
90010
DPST (for breaking both sides of 240 volt loads)
FF415M/FD415M
–––
FF430M/FD430M
–––
FF460M/FD460M
–––
FF46H/FD46H
–––
FF412H
–––
Tork††
Paragon†††
–––
–––
–––
–––
–––
–––
–––
–––
–––
–––
–––
–––
–––
–––
–––
–––
–––
–––
–––
–––
–––
–––
–––
–––
† FF Models with brushed aluminum plate for commercial/industrial applications. FD Models-decorator design with ivory or white time dial for use with existing toggle or decorator style switch plate.
†† Decorator models only.
††† PSW series no longer available; replaced by SW and SWD series
Next Generation 365 Day Multi-Function Electronic Time Switches
INTERMATIC
Paragon
Tork
Lithonia
ET70115C (SPDT)
*(SPST)
**(DPDT)
EL71/Series
EC7001/208-240V
EC7001/277V
EC7001/208-277V
EC7004/208-240V*
EC7004/277V*
EC7004/208-277V*
EC71/18S/120V
EC71D/18S/240V
EC71ST/120V
EC71ST/240V
EC71ST/277V
EC71STM/120V
EC71STM/277V
EC365/C/120V
EL71PC/Series
EC71STN3/120V
DT100**
DT100-2**
DT100-3**
DZS100**
––
ET70115CR (SPDT)
**(DPDT)
ET70115CR24
for 24 Volt / 60 Hz
Input only
148
INTERMATIC
ET70215C
ET70215CR
Paragon
EL72/Series
EC72/120V
EC72/240V
EC72/277V
EC72D/120V
EC72D/240V
EC72ST/120V
EC72ST/240V
EC72ST/277V
EL72PC/Series
EC72STN3/120V
ET70215CR24
for 24 Volt / 60 Hz
Input only
DZS100A
DTS100A
DG180
DG180-2
DG180-3
DG100
DG100-2
DG100-3
DG120**
DG120-2**
DZS100**
DZS100-2**
DZS100-3**
DGS100
DGS100-2
DGS100-3
DGS180
DGS180-2
DGS180-3
DGM100**
DGM100-2**
DGM100-3**
DWZ100A**
—
ET70415CR
ET70415CR24
for 24 Volt / 60 Hz
Input only
ET70815CR
—
ET70815CR24
for 24 Volt / 60 Hz
Input only
IMPORTANT NOTE: Review manufacturer’s literature for
possible feature differences
ET71615CR
ET71615CR24
for 24 Volt / 60 Hz
Input only
EL74
EC74/50S/120V
EC74/50S/240V
EC74/120D/120/240V
EC74/192MA/120/240V
EL78
EC77/140/120, 240V
EL712
EC712/120, 240V
EC128
Tork
DT200
DT200-2
DT200-3
Lithonia
––
DZS200A
DTS200A
DZM200A
DS200
DS200-2
DS200-3
DZS200
DZS200-2
DZS200-3
DZM200
DZM200-2
DZM200-3
DZS400A
DTS400A
Z400B
Z400B-2
K400Z
K400Z-2
K401Z
K401Z-2
DIN103A
(3PDT)
K600Z
K800Z
K600Z-2
K800Z-2
K601Z
K601Z-2
K801Z
K801Z-2
AI200
A1600
––
––
LITEKEEPER
LK8
LK16
CK16
LK32†
CK32†
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Cross Reference
Weatherproof Outdoor Receptacle Covers
Intermatic
WP1000C
WP1000GC
WP1000HC
WP1000HGC
WP1000RC
WP1000HRC
WP1010C
WP1010HC
WP1010HMC
WP1010MC
WP1020C
WP1030C
WP1030MC
WP1050
WP1100C
WP1110C
WP1150C
WP1100WC
WP1110WC
WP1220C
WP1230C
WP1250C
WP2000
Taymac
Carlon
Cooper
Arlington
T&B
Raco
P&S
n/a
n/a
n/a
n/a
71101*
n/a
n/a
n/a
MX3300
MX3200
MM2440C
n/a
MX6200*
MM7440C
MM400C
n/a
MM740C
n/a
n/a
MM2440C*
n/a
MM7440C*
n/a
E9UVCRN
E9UVGRN
E9UHCRN
E9UVGRN
n/a
n/a
E9UDVCRN
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
E9U2CRN*
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
WIU-1
n/a
WIU-1D
WIU-1W
n/a
WIU-2*
n/a
n/a
n/a
n/a
n/a
n/a
n/a
DBV* series
DBV* series
n/a
n/a
n/a
n/a
DBUL1DC
n/a
n/a
n/a
DBU1C
n/a
n/a
DBUL1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
CKMD*
CKSDV*
n/a
n/a
2CKD*
n/a
CKNM*
n/a
n/a
n/a
n/a
2CKNM*
n/a
n/a
n/a
5752-0*
n/a
5761-0*
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
5770-0*
n/a
5789-0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
WIUC10CL
n/a
WIUC10DL
WIUC10WL
n/a
n/a
WIUC20CL
n/a
n/a
*Competitive product does not meet all possible device configurations and installation methods that the Intermatic cover handles.
7-Day Electronic Time Switches
24 Hour Electronic Time Switches
INTERMATIC
Paragon
Tork
EZ Controls
INTERMATIC
Paragon
Tork
EZ Controls
ET171C (SPST)
*(SPDT)
EC7000/120*
ES101, EW101
ES120*, EW120*
DG100*, DG180*
DIN101A*
ES103, EW103
EZ-701-1
ET100C (SPST)
*(SPDT)
EC1015P/120*
EC4000/120*
EC4004/120
EC4004P/120
EC4004PC/120
EC4000P/120*
EC4000PC/120*
EC11 & 11D/120*
—
E101, E120*
EZ-T101
E101, E120*
EZ-T101
E101-2
EZ-T102
EC7004/120
ET173C (DPST)
EC7005/120
ET174C (DPST)
*(SPDT)
EC7000/208-240*
ET279C (SPST)
*(SPDT) **(DPDT)
EC7000/277*
EC7004/208-240
EC7004/277
EC7005/120, 208-240
EC7005/277
EC11 Series*
EC7001/120*
ET8115C
EC71/30S/120
ES103-2,ES103-3
ES120-2*, ES120-3*
EW103-2,
EW103-3
DGM100**
CD100A, DS200**
DIN100*, DIN200*
E, ES & EW120
DG100, DG180
EZ-701-1A
EZ-701-2
EZ-701-2A
EZ-701-72
ET101C (SPST)
*(SPDT)
ET102C (SPST)
*(SPDT)
EZ-701-2M**
EZ-T105
EZ-701-1A
(SPST)
ET8215C
ET8215C
*(SPDT) **(DPDT)
EH10††
EH40††
—
EC71D/30SM/
120*
—
—
†† With external load indicator and external load override.
DIN101A
DG120 (DPDT)
DGM100
—
EZ-701-2M
EH10
EH20
—
—
**(DPST)
ET103C (DPST)
ET104C (DPST)
EC1015P/208-277
EC4000/208-277*
EC4004/208-277
EC4004P/208-277
EC4000P/208-277
EC4004PC/208-277
EC4005P/120, 208-240**
EC4005PC/120, 208-240**
EC11D/240*
—
EC4005/120-240
E101-3
E120-2*
E120-3*
E103
E103-2, E103-3
EZ-T103
EZ-T104
Astronomic Electronic Time Switches
INTERMATIC
Paragon
Tork
EZ Controls
ET70115CR† (SPDT)
EC71ST/120
EC71ST-N3/120V
EC71ST/277
DZS100
EZ-701-2AS
DZS100-3
EZ-701-72AS
† Replaces ET816CR and ET833CR.
NOTE: ET70000 Series provides astronomic programming for any circuit(s).
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
149
Cross Reference
High Intensity Discharge (HID) Lighting
Intermatic
RAB
Stonco
Intermatic
RAB
Stonco
WL050MH
WL070MH
WL100MH
WL150MH
WL175MH
WL250MH
WL400MH
WL035HPS
WL050HPS
WL070HPS
WL100HPS
WL150HPS
WL250HPS
WL400HPS
FL050MH
FL070MH
FL100MH
FL150MH
WP1H50
WP1H70
WP1H100
WP2H150QT
WP2H175QT
WP3H250QT
WP4H400QT
WP1SN35
WP1SN50
WP1SN70
WP1SN100
WP2SH150QT
WP3SC250QT
WP4SC400QT
FFH50
FFH70
EZHH100QT
EZHH150QT
LPSC50MA-8
LPSC70MA-8
LPM2C100MA-8
WPM150MA-8
WPM175MA-8
WP250MA-8
WP400MA-8
WNPS35NLXL
WNPS50NLXL
WNPS70NLXL-8
WNPS100NLXL-8
WPM150NLXL-8
WP250NLXL-8
WP400LXL-8
TLX50NMAL-1
SLA70NMAL-1
SLA100MAL-8
SLA150MAL-8
FL175MH
FL250MH
FL400MH
FL035HPS
FL050HPS
FL070HPS
FL100HPS
FL150HPS
FL250HPS
FL400HPS
DD175MV
DD150HPS
FL150Q
FL300Q
FL500Q
WL070HPSPC
CP150HPS
EZHH175QT
FZH250QT
FZH400QT
FF35
FF50
FF70
EZSH100
EZSH150QT
FZS250QT
FZS400QT
YLM175
YLS150
QF150
QF300
QF500
WPTS70
VAN5S150QT
SLA175MAL-8
SLM250MAL-8
SLM400MAL-8
TLX35NLXL-1
TLX50NLXL-1
TLX70NLXL-1
SLA100LXL-8
SLA150LXL-8
SLM250LXL-8
SLM400LXL-8
DTDA175NMML-1
DTDA150NLXL-1
EQX150L
EQ300L
EQ500L
TLW70NLXL-1
LCQ155LXL-8
Electronic Astronomic Time Switches
Intermatic
Paragon
SPST Astro Time Switches in NEMA 1 Case
ET8015C
—
SPST Astro Time Switches in NEMA 3R Case
ET8015CR
EC365DST1/120V
SPDT Astro Time Switches in NEMA 1 Case
ET8115C
—
SPDT Astro Time Switches in NEMA 3R Case
ET8115CR
EL71/120V
EL71/208-240V
EL71/277V
DPST Astro Time Switches in NEMA 1 Case
ET8215C
—
DPST Astro Time Switches in NEMA 3R Case
ET8215CR
EC365DST2/120V
EC365DST2/277V
EL72/120V
EL72/208-240V
EL72/277V
150
Electronic Auto-Off Timers
Tork
—
—
—
DWZ100A
DZS100A
—
DW200A
DZS200A
Intermatic
5-10-15-30 Minute Range
EI200
EI200LA
EI200W
10-20-30-60 Minute Range
EI210
EI210LA
EI210W
1-2-4-8 Hour Range
EI220
EI220LA
EI220W
2-4-8-12 Hour Range
EI230
EI230LA
EI230W
Leviton
Leviton
6230MI
6230MA
6230MW
—
—
—
6260MI
6260MA
6260MW
6560MI
6560MA
6560MW
—
—
—
—
—
—
6212HI
6212HA
6212HW
6512HI
6512HA
6512HW
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
Cross Reference
Photo Controls
Intermatic
ALR
Tork
Ripley
Mulberry
Precision
Paragon
Fisher Pierce
K4021C
K4024
K4022
K4033
K4023C
K4035
K4321C
K4121C
K4124
K4122
K4123C
K4133
K4135
K4141C
K4221C
K4224
K4222
K4233
K4235
K4236
K4121M
K4123M
K4136M
K4251
K4253
LC4521C/K4521
LC4521LA
LC4523
LC4523LA
LC4535
LC4535LA
LC4536C
LC4536LA
K4524
K4522
K4533
K4535
K4023*
K1121
K1122
LC2000
LC2000
Accessories
K4500
K121
K122
AA105
AA106
AA107
AA108
AA1068
—
AA105W
PT15
AT16
AT17
PT168/AT368
AT18
AT19/PT19/AT39
AT30 (metal)
SAT15/SPT15
SAT16
SAT17
SAT18
SAT19/SPT19
PT20/SAT168/SPT168
AT15
AT168
AT20
TL115
TL168
LC120
BF120/M120
LC208-277
BF208-277/M208-277
—
BF480/M480
—
BFPV/MPV
—
—
—
—
AA1068W/AA1068P
—
—
—
—
3000
—
—
—
3002
—
3010
2101/2100
—
—
—
—
—
2105 (polycarbonate)
2001/3020
—
—
—
—
2104/2102/2002
2101
2104
2107
2021
2022
2003/5001S
2003S/5021S
2004/5004S
2004S/5024S
—
2008D/5008S/2008**
—
2007D/5007S/2007**
—
—
—
2008
—
—
—
2005
2007
7001/7011
—
—
—
7002/7003/7012/7013
—
7105
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
7046
—
7049
—
—
6190**
—
—
—
—
—
—
—
—
6146/6281
—
30850
30851
30852
—
30853
—
30855
30825/30820
30827
30829
—
30831
—
30847
30826/30868
—
—
—
—
30830/30833/3082
—
—
—
—
—
30834
—
30837
—
30842
—
30844
—
30836
30838
30840
30842
—
—
—
—
—
A105
—
—
—
A1068
—
A105W
T-15
—
—
T-168
—
T-19
T-30
ST-15
—
—
—
ST-19
ST-168
TL15AL
—
—
ET-15
ET-168
P-2275/M2275
P2275LA
P68275
8672**
P7275
LM7275/8694**
P26275/8690N**
8690**
—
—
—
P7275
A1068W/A1068P
—
—
EC120
EC240,ECDV
LB201-00
—
—
—
LB201-71
—
LB201W-00
CW201-00
—
—
CW201-71
—
—
CW302-00
CW201S-00
—
—
—
—
CW201-71
CW201-00
CW201-71
CW201-70
PN201-00
—
TL201-00
—
TL201-71
—
—
—
TL201-70
—
—
—
—
—
—
—
—
—
—
FA105/FA305/6241A/6210
—
6242A
—
FA1068
—
FA105W
6241B/FT15
—
6242B
FT168
—
FT19
—
SFT15
—
—
—
SFT19
SFT168
FT15
FT168
—
FL115
—
NFP120/N6401-NS
NFP120H/N7760-SSS**
NFP277
NFP-277H/M208-277
—
7790B-NSS**
7790B-ESS**/N7790B
—
—
—
—
—
—
—
7760/7762/7790B/7792B
7770/7772/7790B
SC10
AM1ANB
AM1A, AM2A, AM2ANB
2500/5500
2223/2224
2421/2422
6005/6007
—
5925/5926/5927
30846
—
30862
JP275
603
M2A
SC201-99
—
TB201-99
NS1038-1
NS47681
NS476-71/NS476-732
* With K4001
** Quick response type
For quick access to Intermatic Energy Control products and Weatherproof Covers simply go
to www.intermatic.com/energycontrols
This will take you directly to our Energy Controls Search where you may search for products
by Application, by Feature, by Series or by Category.
This file provides you the ability to download and print specifications, wiring diagrams and
product photographs. Many of our instruction sheets, all in pdf format, can also be found on
the site.
WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER
151
INDUSTRIAL & COMMERCIAL
SALES REPRESENTATIVES
CORPORATE HEADQUARTERS:
7777 Winn Road
Spring Grove, IL 60081
Phone: (815) 675-2321
Fax: (815) 675-7105
www.intermatic.com
1. * DAVID ROLE & COMPANY 216 New Boston Street,
Woburn, MA 01801
Phone: (781) 932-8810 FAX: (781) 932-8815
2.
P&M SALES, LTD. 400 Chapel Road,
Unit 2-1, South Windsor, CT 06074-4169
Phone: (860) 528-9181 FAX: (860) 528-7050
3. * BURGOYNE SALES, INC. 110 McGaw Drive, Raritan
Industrial Center, Edison, NJ 08837
Phone: (732) 225-0450 FAX: 732-225-7454
Effective January 2007
MILLS TALBOT CO. 100 Thompson Street,
Fayetteville, NY 13066
Phone: (315) 637-0511 FAX: (315) 637-0512
22.
ELECTRA SALES 2320 Hinton Drive,
Irving, TX 75061
Phone: (972) 554-8200 FAX: (972)554-7861
39.
BAILEY/MARTIN & ASSOCIATES 935 6th Ave. South,
Nashville, TN 37203
Phone: (615) 256-3000 FAX: (615) 242-6780
5. * R.C. COLERICK, INC. 1244 Ritchie Hwy., Suite 13,
Arnold, MD 21012
Phone: (410) 421-9511 FAX: (410) 421-9514
23.
ELECTRA SALES 2200 SW 14th St.,
Oklahoma City, OK 73108
Phone: (405) 722-6905 FAX (405) 722-2458
40.
CURTIS H. STOUT INC. 310 Edgewood Terrace,
Suite B, Jackson, MS 39206
Phone: (601) 366-1903 FAX: (601) 981-8439
6. * SYNERGY ELECTRICAL SALES 95 Canal Rd., Penn
Warner Industrial Park, Fairless Hills, PA 19030
Phone: (800) 220-5691 FAX: (215) 428-1137
24.
CURTIS H. STOUT INC. 2400 Cantrell Road, Suite
100, Little Rock, AR 72202
Phone: (501) 372-2555 FAX: (501) 375-4451
41.
7.
25.
CURTIS H. STOUT INC. 3478 Winhoma Drive,
Memphis, TN 38118
Phone: (901) 362-1616 FAX: 901-795-0481
INTERMATIC INCORPORATED CANADA 6430-B
Kennedy Rd. Unit B Mississauga, Ontario L5T 2Z5
Canada Phone: (905) 696-7621 FAX: (905) 6960846
4.
Electra Products, Inc. 2750 Breckinridge Blvd
Suite 400 Duluth, GA 30095 Phone: (770) 451-9146
Phone: (800) 225-4820 FAX: (770) 451-9424
8. * PAOLICELLI & ASSOCIATES Gregg & Hammond
Sts., Carnegie Industrial Park, P.O. Box 665,
Carnegie, PA 15106-0665
Phone: (412) 276-8816 FAX: (412) 276-6670
26.
CURTIS H. STOUT INC. 201 Evans Road, #110,
Harahan, LA 70123
Phone: (504) 818-1848 FAX: (504) 818-1631
INTERMATIC CANADIAN WAREHOUSE 1200 Cardiff
Blvd, Mississauga, Ontario L5S 1P6
FAX: 1(800) 700-9671
42.
INTRALEC ELECTRICAL PRODUCTS LTD. 1200
Cardiff Blvd, Unit 1, Mississauga, Ontario Canada
L5S 1P6
Phone: (905) 670-0970 FAX: (905) 670-3098
27.
STOVER & ASSOCIATES, INC. 4460 W. 107th St.,
Shawnee Mission, KS 66207
Phone: (913) 649-6600 FAX: (913) 649-2762
43.
28.
JOE BERTSCH ELECTRICAL SALES 5832 Dry Creek
Lane N.E., Cedar Rapids, IA 52402,
Phone: (319) 395-9220 FAX: (319) 395-9224
ADANAC #3-2075 Brigantine Drive, Coquitlam,
British Columbia, Canada V3K 7B8
Phone: (604) 540-0220 FAX: (604) 540-0124
44.
29.
Interwest 345 West 62nd Ave.
Suite B Denver, CO. 80216
Phone: (303) 650-5162 FAX: (303) 650-5165
JOE BERTSCH ELECTRICAL SALES 201 S. 84th St,
Suite D, Lincoln, NE 68510
Phone: (402) 488-1614 FAX: (402) 488-1615
D.A.D. SALES 2013, 17th Ave., Didsbury, Alberta
TOM OWO, Canada T2G 5G5
Phone: (403) 335-3531 FAX: (403) 335-8347
45.
30.
12. * RIFFLE & ASSOCIATES INC. 2671 Crescentville Rd.,
Cincinnati, OH 45241
Phone: (513) 771-0002 FAX: (513) 771-0011
JOE BERTSCH ELECTRICAL SALES 8450 Hickman
Rd., Suite 15F, Des Moines, IA 50325
Phone: (515) 276-8967 FAX: (515) 276-8968
JEBCO AGENCIES, LTD. #4 - 2225 First Avenue
North, Saskatoon, Saskatchewan, Canada S7K 2A5
Phone: (306) 373-0771 FAX: (306) 374-8023
46.
31.
LEE-NOONAN CO. 2230 Country Rd. H2,
Moundsview, MN 55112
Phone: (763) 278-1036 FAX: (763) 560-3282
JEBCO AGENCIES, LTD. Unit 19 – 1865 Sargent
Avenue, Winnipeg, Manitoba Canada R3H 0E4
Phone: (204) 786-2604 FAX: (204) 786-4734
47.
32.
CENTAURI SALES 10708 Elena Dr. NE,
Albuquerque, NM 87122
Phone: (505) 823-9816 FAX: (505) 823-9608
CONTACT DELAGE, INC. 135 J.A. Bombardier, Suite
90, Boucherville, Quebec Canada J4B 8P1
Phone: (450) 449-9444 FAX: (450) 449-6090
48.
BROCKWAY ENTERPRISES 51 Cobequid Road,
Suite 203 Lower Sackville, Nova Scotia, Canada
B4C 2N1
Phone: (902) 865-4192 FAX: (902) 865-5967
49.
BROCKWAY ENTERPRISES 7 Howard Court,
Quispamsis, New Brunswick, Canada E2E 4J6
Phone: (506) 849-6000 FAX: (506) 847-5329
50.
BROCKWAY ENTERPRISES 62 Kerry Avenue,
Conception Bay South, New Foundland,
Canada A1X 7H7
Phone: (709) 834-7444 FAX: (709) 834-7446
51.
BOB JONES & ASSOCIATES 3837 E. Anne Street,
Phoenix, Arizona 85040
Phone: (602)-437-1111 FAX: (602)-437-2339
9. * E.F. LOMBARDI CO. P.O. Box 669186, Charlotte, NC
28266, 2101 Freedom Drive, Charlotte, NC 28208
Phone: (704) 334-1637 FAX: (704) 372-6078
10. * INTERMATIC INCORPORATED 3150 NW Prospect
Road, Suite 330, Ft. Lauderdale, FL 33309
Phone: (954) 535-0020 FAX: (954) 535-0040
11.
13. * L.P. CHICK CO. P.O. Box 19021, Louisville, KY
40259-0021; 1110 Industrial Blvd., Louisville, KY
40219
Phone: (502) 964-8181 FAX: (502) 964-8196
14.
15.
16.
17.
18.
19.
20.
RIFFLE & ASSOCIATES 16760 W. Park Circle Dr.,
Chagrin Falls, OH 44023
Phone: (440) 543-8257 FAX: (440) 543-7236
ELECTROCOM-MIDWEST SALES, INC. (EAST) 32500
Concord Drive, Suite 298, Madison Heights, MI
48071
Phone: (248) 307-1640 FAX: (248) 307-1630
ELECTROCOM-MIDWEST SALES, INC. (WEST) 4485
Plainfield N.E. Suite 103, Grand Rapids, MI 49525
Phone: (616) 364-8084 FAX: (616) 364-0135
ARTHUR A. BOYLE CO., INC. 5172 E. 65th Street,
Indianapolis, IN 46220 Phone: (800) 776-9101
(317) 577-9100 FAX: (317) 577-9161
LAKESHORE ELECTRICAL, INC. 614 W. Brown Deer
Rd., Suite 230, Bayside, WI 53217
Phone: (414) 228-0580 (800) 229-2227
FAX: (414) 228-0585
INTERMATIC INCORPORATED CORPORATE OFFICES
Intermatic Plaza, Spring Grove, IL 60081-9698
Phone: (815) 675-2321 FAX: (815) 675-7105
MARTIN ELECTRICAL SALES, INC. 136 West
Adams, P.O. Box 220189, Kirkwood, MO 63122
Phone: (314) 966-8659 FAX: (314) 966-6748
21. * ETEL 7106 Cavalcade, Houston, TX 77028
Phone: (713) 678-4460 FAX: (713) 678-4371
33. * BLOMQUIST, DENSELY & YOUNG (BDY) 2550 Decker
Blvd. – #28, Salt Lake City, UT 84119 Phone: (801)
972-0070 FAX: (801) 973-0526
34. * PRO-LINES SALES & MARKETING P.O. Box 58248,
Tukwila, WA 98138, 18700 – 80th Place South,
Kent, WA 98032
Phone: (425) 272-0348 FAX: (425) 272-0362
35.
PRO-LINES SALES & MARKETING SOUTH
7272 SW Durham Road, Suite 750, Portland, OR
97224
Phone: (503) 692-6993 FAX: (503) 612-6706
36. * INTERMATIC INCORPORATED 10524 Pioneer Blvd.,
Santa Fe Springs, CA 90670
Phone: (562) 906-0900 FAX: (562) 906-0955
37. * LAU COMPANY 47-096 Kam Hwy, Kaneone Oahu,
HI 96744
Phone: (808) 234-0199 FAX: (808) 235-7765
38.
CURTIS H. STOUT INC. 11051 Coursey Blvd., Suite
B, Baton Rouge, LA 70816
Phone: (225) 291-5709 FAX: (225) 291-5713
* indicates carries stock of industrial and consumer products
PRINTED IN U.S.A. ©COPYRIGHT 2007 INTERMATIC INC. TS89
300TS10057
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project