- No category
advertisement
▼
Scroll to page 2
of 9
FE NIE X . 2016 INSTRUCTION MANUAL W E B. w w w.feniex.com Fusion Stick Light- Instruction Manual V.1 FUSION Model # - F-12013, F-22013, D-50115, D-50215, D-50415, D-50615, D-50815, D-51015 This instruction manual serves as a guide for the Fusion Series. IMPORTANT! Please read through all provided instructions and any listed warnings in regards to product use. Distributed By: Feniex Product Copyrights This price List and the mentioned Feniex products include or describe copyrighted Feniex material. Laws in the United States and other countries preserve for Feniex Industries and its licensors certain exclusive rights for copyrighted material, including the exclusive right to copy, reproduce in any form, distribute and make derivative works of the copyrighted material. Accordingly, any copyrighted material of Feniex and its licensors contained herein or in the Feniex products described in this Price List may not be copied, reproduced, distributed, merged or modified,transmitted, transcribed, stored in retrieval system or translated into any language or computer language, in any form or by any means, without prior written permission of Feniex Industries, Inc.. Feniex and the stylized Feniex logo are registered in the U.S. Patent & Trademark Office. Table of Contents TM V1.0 Equipment Dimensions 3 Wiring Diagram 4 Flash Patterns 7 Mounting Instructions 9 2 FE NIE X . 2016 INSTRUCTION MANUAL WE B. w w w.feniex.com TM Equipment Dimensions V1.0 9.5 in. Fusion 200 1.25in. 2.25in. 18 .82 in. Fusion 400 1.25in. 2.25in. 28 .14 in. Fusion 600 1.25in. 37 2.25in. .46 in. Fusion 800 64 in. 1.25in. 2.25in. Fusion Rocker Panel 1.25in. 2.25in. FE NIE X . 2016 INSTRUCTION MANUAL W E B. w w w.feniex.com 3 1X, 2X, 100, & 200 Wiring Diagram TM V1.0 Fusion 200 Wiring Fusion 200 System Specification Wire Color: Black Red Blue Yellow Function: 12V (-) 12V (+) Mode 1 Pattern/Sync Mode 2 Please Note! The Fusion 200 features four wires: Red [12V+], Black [12V-], White [12V+], and Green [Flash Pattern Changer]. To change patterns, momentarily connect the green wire to the activated Black [12V-] wire. Note that Mode 2 will override Mode 1. 4 FE NIE X . 2016 INSTRUCTION MANUAL WE B. w w w.feniex.com TM 400, 600, 800 & Rocker wiring diagram V1.0 Fusion 400, 600 & 800, Rocker Panel Wiring Fusion 400, 600, 800 & Rocker Panel Wiring Diagram Wire Color: Black Single Color: Dual Color: 12V (-) 12V (-) 12V (+) 12V (+) Takedown Takedown/Flood Flash Mode Flash Mode Green Takedown Flashing* Mode Two Brown Left Arrow Left Arrow Lightbar On Mode One Right Arrow Right Arrow Center Out Center Out Red White Yellow Blue Gray Blue/Gray *Please Note! These modes only function when the unit has takedowns in the assembly. FE NIE X . 2016 INSTRUCTION MANUAL W E B. w w w.feniex.com 5 400, 600, 800 & Rocker wiring instructions Step 1: In order to power the unit, extend the red, 12V(+) wire to the 12V(+) post of the vehicle’s battery. Extend the black 12V(-) wire to the ground post of the vehicle’s battery. Step 2: To turn the lightstick on, connect the brown wire to a 12V(+) source. Step 3: Momentarily connect the yellow wire on a 12V(+) source to change flash patterns. Step 4: For left arrow function, connect the blue wire to a 12V(+) post (switch). There are 2 different left arrow flash patterns. To select a pattern, engage the blue wire to a 12V(+) source and momentarily connect the yellow wire on a 12V(+) source to select the desired pattern. TM V1.0 Step 5: For right arrow function, connect the gray wire to a 12V(+) post (switch). There are 2 different right arrow flash patterns. To select a pattern, engage the gray wire a 12V(+) source and momentarily connect the yellow wire on a 12V(+) source to select the desired pattern. Step 6: In order to achieve a center out directional pattern, connect both the gray and blue wires to a 12V(+) post (switch). There are 2 different center out flash patterns. To select a pattern, engage the blue and gray wire to a 12V(+) source and momentarily connect the yellow wire on a 12V(+) source to select the desired pattern. Step 7: For takedown steady functionality, connect the white wire to a 12V(+) post (switch). Step 8: For takedown flashing, connect the green wire to a 12V+ (post). Please note that for dual color bars, the green wire will activate mode 2, unless otherwise programmed. Important Note! Takedown steady overrides takedown flashing Activate Takedown Flashing for Dual Color: Step 1: Connect the black wire to the battery’s 12V(-) ground. Step 2: Select the wire that will be set as the takedown flashing mode wire, either the green or brown wire. Step 3: Twist the selected mode (green or brown), red, white, and yellow wires together. 6 FE NIE X . 2016 INSTRUCTION MANUAL WE B. w w w.feniex.com Step 4: Power the lightbar on by connecting the twisted wires to the battery’s positive (+). Once activated, the takedown steady function will engage. To verify takedowns are flashing, disconnect Takedown Steady (white) wire from power. Step 5: Repeat steps 1 through 3 to deactivate Takedown Flashing. TM Flash Patterns V1.0 The flash patterns are listed in consecutive order of appearance. To select a certain flash pattern, start with a recognizable pattern and use the blue wire to cycle through patterns. Flash Patterns Single Color: Fusion 400, 600, 800 & Rocker Panel Flash Patterns Dual Color: Fusion 200, 400, 600, 800 & Rocker Panel 2. 2. 1. Cluster 3. Night Rode 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. Attack Combo Slow-Fast Combo Slow Combo Fast Half Half Slow Half Half Fast One One Slow One One Fast Two Two Slow Two Two Fast All On Slow All On Fast In Out Slow In Out Fast Left Arrow Slow Left Arrow Medium Left Arrow Fast Right Arrow Slow Right Arrow Medium Right Arrow Fast Center Out Slow Center Out Medium Center Out Fast 1. Color 1-Cluster 3. Color 1-Night Ride 4. 5. 6. 7. 8. 9. Color 1-Attack Color 1-Combo Slow-Fast Color 1-Combo Slow Color 1-Combo Fast Color 1-Half Half Slow Color 1-Half Half Fast Color 1-One One Slow 10. Color 1-One One Fast 11. Color 1-Two Two Slow 12. Color 1-Two Two Fast 13. Color 1-All On Slow 14. Color 1-All On Fast 15. Color 1-In Out Slow 16. Color 1-In Out Fast 17. Color 1-Left Arrow Slow 18. Color 1-Left Arrow Medium 19. Color 1-Left Arrow Fast 20. Color 1-Right Arrow Slow 21. Color 1-Right Arrow Medium 22. Color 1-Right Arrow Fast 23. Color 1-Center Out Slow 24. Color 1-Center Out Medium 25. Color 1-Center Out Fast 26. Color 2-Cluster 27. Color 2-Attack 28. Color 2-Night Ride 29. Color 2-Combo Slow-Fast 30. Color 2-Combo Slow 31. Color 2-Combo Fast 32. Color 2-Half Half Slow FE NIE X . 2016 INSTRUCTION MANUAL W E B. w w w.feniex.com 7 TM Flash Patterns Flash Patterns Dual Color: Fusion 200, 400, 600, 800 & Rocker Panel 33. Color 2-Half Half Fast 34. Color 2-One One Slow 35. Color 2-One One Fast 36. Color 2-Two Two Slow 37. Color 2-Two Two Fast 38. Color 2-All On Slow 39. Color 2-All On Fast 40. Color 2-In Out Slow 41. Color 2-In Out Fast 42. Color 2-Left Arrow Slow 43. Color 2-Left Arrow Medium 44. Color 2-Left Arrow Fast 45. Color 2-Right Arrow Slow 46. Color 2-Right Arrow Medium 47. Color 2-Right Arrow Fast 48. Color 2-Center Out Slow 49. Color 2-Center Out Medium 50. Color 2-Center Out Fast 51. Color 1&2-Cluster 52. Color 1&2-Attack 53. Color 1&2-Night Ride 54. Color 1&2-Combo Slow-Fast 55. Color 1&2-Combo Slow 56. Color 1&2-Combo Fast 57. Color 1&2-Half Half Slow 58. Color 1&2-Half Half Fast 59. Color 1&2-One One Slow 60. Color 1&2-One One Fast 61. Color 1&2-Two Two Slow 62. Color 1&2-Two Two Fast 63. Color 1&2-All On Slow 64. Color 1&2-All On Fast 8 FE NIE X . 2016 INSTRUCTION MANUAL WE B. w w w.feniex.com V1.0 Flash Patterns Dual Color: Fusion 200, 400, 600, 800 & Rocker Panel 65. Color 1&2-In Out Slow 66. Color 1&2-In Out Fast 67. Color 1&2-Left Arrow Slow 68. Color 1&2-Left Arrow Medium 69. Color 1&2-Left Arrow Fast 70. Color 1&2-Right Arrow Slow 71. Color 1&2-Right Arrow Medium 72. Color 1&2-Right Arrow Fast 73. Color 1&2-Center Out Slow 74. Color 1&2-Center Out Medium 75. Color 1&2-Center Out Fast TM Mounting V1.0 Step 1: To mount to bracketry, remove the flat endcap and slide in provided bolts in the back of the frame. Screw the flat endcap back into the aluminum extrusion with the original screws and attach bolts and nuts with the brackets. Step 2: Mark the areas where the mounting holes will be drilled. If mounting surface is part of the vehicle, make sure no vital components could be damaged by the drilling process. Step 3: Drill two mounting holes in the marked surface. If wires need to pass through vehicle, drill a 0.5” diameter hole for wire passage. Make sure to deburr holes thoroughly. Step 4: Pass the wires through the 0.5” diameter hole, and secure the lighthead to the mounting surface with the provided hardware. 1 Figure 5.0 2 3 Item #: 1. Description: Cobra Extrusion 2. Mounting Hardware 3. Mounting Bracket 3 FE NIE X . 2016 INSTRUCTION MANUAL W E B. w w w.feniex.com 9
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project