OMRON Corporation:CS/CJ Series Ethernet

OMRON Corporation:CS/CJ Series Ethernet
OMRON Corporation
CS/CJ Series
Ethernet Driver
1
System Configuration....................................................................................................... 3
2
Selection of External Device ............................................................................................ 6
3
Example of Communication Setting ................................................................................. 7
4
Setup Items .................................................................................................................... 19
5
Supported Device........................................................................................................... 23
6
Device Code and Address Code.................................................................................... 25
7
Error Messages.............................................................................................................. 26
1
CS/CJ Series Ethernet Driver
Introduction
This manual describes how to connect the Display and the External Device (target PLC).
In this manual, the connection procedure will be described by following the below sections:
1
System Configuration
This section shows the types of External
Device which can be connected and SIO
type.
)"1 System Configuration" (page 3)
2
Selection of External Device
Select a model (series) of the External
Device to be connected and connection
method.
)"2 Selection of External Device" (page 6)
3
Example of Communication Settings
This section shows setting examples for
communicating between the Display and
the External Device.
)"3 Example of Communication Setting"
Setup Items
This section describes communication
setup items on the display.
Set communication settings of the Display
with GP-Pro Ex or in off-line mode.
)"4 Setup Items" (page 19)
4
Operation
GP-Pro EX Device/PLC Connection Manual
2
(page 7)
CS/CJ Series Ethernet Driver
1
System Configuration
The system configuration in the case when the External Device of OMRON Corporation and the Display are
connected is shown.
Series
CS Series
CJ Series
*1
CPU
CS1H-CPU67
CS1H-CPU66
CS1H-CPU65
CS1H-CPU64
CS1G-CPU45
CS1G-CPU44
CS1G-CPU43
CS1G-CPU42
CS1H-CPU67H
CS1H-CPU66H
CS1H-CPU65H
CS1H-CPU64H
CS1H-CPU63H
CS1G-CPU45H
CS1G-CPU44H
CS1G-CPU43H
CS1G-CPU42H
CS1H-CPU67-V1
CS1H-CPU66-V1
CS1H-CPU65-V1
CS1H-CPU64-V1
CS1H-CPU63-V1
CS1G-CPU45-V1
CS1G-CPU44-V1
CS1G-CPU43-V1
CS1G-CPU42-V1
CJ1G-CPU45
CJ1G-CPU44
CJ1M-CPU23
CJ1M-CPU22
CJ1M-CPU21
CJ1M-CPU13
CJ1M-CPU12
CJ1M-CPU11
CJ1H-CPU66H
CJ1H-CPU65H
CJ1G-CPU45H
CJ1G-CPU44H
CJ1G-CPU43H
CJ1G-CPU42H
Link I/F
Setting Example
Ethernet (UDP)
Setting Example 1
(page 7)
Ethernet (UDP)
Setting Example 3
(page 13)
Ethernet (TCP)
Setting Example 4
(page 16)
Ethernet (UDP)
Setting Example 2
(page 10)
Ethernet (UDP)
Setting Example 3
(page 13)
Ethernet (TCP)
Setting Example 4
(page 16)
CS1W-ETN01
CS1W-ETN11
CS1W-ETN21*1
CJ1W-ETN01
CJ1W-ETN11
CJ1W-ETN21*1
Supporting TCP/IP
GP-Pro EX Device/PLC Connection Manual
SIO Type
3
CS/CJ Series Ethernet Driver
„ Device Configuration
•
1:1 Connection
Ethernet
Display
•
External
Device
1:n Connection
Display
Ethernet
HUB
External
Device
External
Device
External
Device
External Device Max 32 units (UDP/IP connection)
•
1:n Connection (access beyond network)
Set the relay node between networks to allow you to access the PLC with the different network address. You can
access beyond maximum 3 levels of network.
External Device Max 32 units (UDP/IP connection)
Network 2
Display
Ethernet
External
Device
External
Device
Network 1
GP-Pro EX Device/PLC Connection Manual
External
Device
External
Device
Network 3
4
CS/CJ Series Ethernet Driver
•
m:1 Connection
Display
Display
Display
Ethernet
HUB
Ethernet
External
Device
• The number of GP units has no limit. Note that more number of connecting units will result in
increasing the communication load.
•
m:n Connection
m Units
Display
Display
Display
Ethernet
HUB
Ethernet
External
Device
External
Device
External
Device
External Device Max 32 units (UDP/IP connection)
• The number of GP units has no limit. Note that more number of connecting units will result in
increasing the communication load.
GP-Pro EX Device/PLC Connection Manual
5
CS/CJ Series Ethernet Driver
2
Selection of External Device
Select the External Device to be connected to the Display.
Setup Items
Setup Description
Maker
Select the maker of the External Device to be connected. Select "OMRON Corporation".
Driver
Select a model (series) of the External Device to be connected and connection method.
Select "CS/CJ Series Ethernet".
Check the External Device which can be connected in "CS/CJ Series Ethernet" in system
configuration.
"1 System Configuration" (page 3)
)
Use System Area
Check this option when you synchronize the system data area of the Display and the device
(memory) of the External Device. When they are synchronized, you can use the ladder
program of the External Device to change screens or to pop up a window on the Display.
Cf. GP Pro-EX Reference Manual "Appendix 1.4 LS Area (Direct Access
Method)"
This can also be set with GP Pro-EX or in the Display off-line mode.
Cf. GP Pro-EX Reference Manual " 5.17.6 Setting Guide of [System Setting
Window]„[Main Unit Settings] Settings Guide‹System Area Setting"
Cf. Maintenance/Troubleshooting "2.15.1 Settings common to all Display
models‹System Area Settings"
Port
Select the Display port to be connected to the External Device.
GP-Pro EX Device/PLC Connection Manual
6
CS/CJ Series Ethernet Driver
3
Example of Communication Setting
Examples of communication settings of the Display and the External Device, recommended by Pro-face, are
shown.
When you use the CS/CJ Series, use GP-Pro EX and the ladder software to set as below.
3.1
Setting Example 1
„ Setting of GP-Pro EX
‹ Communication Settings
To display the setting screen, select [Device/PLC Settings] from [System setting window] in workspace.
• Set the optional network address of the Display in [Network].
• Set the optional node address of the Display in [Node].
GP-Pro EX Device/PLC Connection Manual
7
CS/CJ Series Ethernet Driver
‹ Device Setting
To display the setting screen, click
([Setting]) of External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
When you connect multiple External Device, click
from [Device-Specific Settings] of [Device/PLC
Settings] to add another External Device.
• Set the IP address you set for the External Device in [IP address].
• Set the network address you set for the External Device in [Network].
• Set the node address you set for the External Device in [Node].
‹ Notes
•
Check with a network administrator about IP address. Do not set the duplicate IP address.
•
Set IP address on the External Device for IP address in Device-specific settings.
•
You need to set IP address on the Display in the off-line mode of the Display.
•
The default port No. of the External Device is 9600. Always perform the same settings for the port No. of the
Display and the External Device.
GP-Pro EX Device/PLC Connection Manual
8
CS/CJ Series Ethernet Driver
„ Setting of External Device
Double-click [I/O Table] in the project window to display the [PC I/O Table] window. Select [Unit Settings] from
the menu displayed by right-clicking on the Ethernet unit in the window to select the Ethernet Unit Setting Screen.
Setup Items
Settings
IP Address Conversion
IP Address Table Method
IP Address Table
Node address and IP address you set in the Display.
*2
IP Address Setting Rotary Switch
*1
Option
Source Network Address
Option
Node Address Setting Rotary Switch*2
Option
Unit No. Setting Rotary Switch*2
0
FINS/UDP Port
9600
*1
Parameter used when you access beyond network.
Set in the routing table of "CX-Net Network Configuration". Please refer to the manual of the External Device
for more details.
*2
Set with the rotary switch on the front of the Ethernet unit.
‹ Notes
•
Check with a network administrator about IP address and subnet mask. Do not set the duplicate IP address.
•
Always perform the same settings for the port No. of the Display and the External Device.
GP-Pro EX Device/PLC Connection Manual
9
CS/CJ Series Ethernet Driver
3.2
Setting Example 2
„ Setting of GP-Pro EX
‹ Communication Settings
To display the setting screen, select [Device/PLC Settings] from [System setting window] in workspace.
• Set the optional network address of the Display in [Network].
• Set the optional node address of the Display in [Node].
GP-Pro EX Device/PLC Connection Manual
10
CS/CJ Series Ethernet Driver
‹ Device Setting
To display the setting screen, click
([Setting]) of External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
When you connect multiple External Device, click
from [Device-Specific Settings] of [Device/PLC
Settings] to add another External Device.
• Set the IP address you set for the External Device in [IP address].
• Set the network address you set for the External Device in [Network].
• Set the node address you set for the External Device in [Node].
‹ Notes
•
Check with a network administrator about IP address. Do not set the duplicate IP address.
•
Set IP address on the External Device for IP address in Device-specific settings.
•
You need to set IP address on the Display in the off-line mode of the Display.
•
The default port No. of the External Device is 9600. Always perform the same settings for the port No. of the
Display and the External Device.
GP-Pro EX Device/PLC Connection Manual
11
CS/CJ Series Ethernet Driver
„ Setting of External Device
Double-click [I/O Table] in the project window to display the [PC I/O Table] window. Select [Unit Settings] from
the menu displayed by right-clicking on the Ethernet unit in the window to select the Ethernet Unit Setting Screen.
Setup Items
Settings
IP Address Conversion
IP Address Table Method
IP Address Table
Node address and IP address you set in the Display.
IP Address
Option
*1
Source Network Address
Option
Node Address Setting Rotary Switch*2
Option
Unit No. Setting Rotary Switch*2
0
FINS/UDP Port
9600
*1
Parameter used when you access beyond network.
Set in the routing table of "CX-Net Network Configuration". Please refer to the manual of the External Device
for more details.
*2
Set with the rotary switch on the front of the Ethernet unit.
‹ Notes
•
Check with a network administrator about IP address and subnet mask. Do not set the duplicate IP address.
•
Always perform the same settings for the port No. of the Display and the External Device.
GP-Pro EX Device/PLC Connection Manual
12
CS/CJ Series Ethernet Driver
3.3
Setting Example 3
„ Setting of GP-Pro EX
‹ Communication Settings
To display the setting screen, select [Device/PLC Settings] from [System setting window] in workspace.
• Set the optional network address of the Display in [Network].
• Set the optional node address of the Display in [Node].
GP-Pro EX Device/PLC Connection Manual
13
CS/CJ Series Ethernet Driver
‹ Device Setting
To display the setting screen, click
([Setting]) of External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
When you connect multiple External Device, click
from [Device-Specific Settings] of [Device/PLC
Settings] to add another External Device.
• Set the IP address you set for the External Device in [IP address].
• Set the network address you set for the External Device in [Network].
• Set the node address you set for the External Device in [Node].
‹ Notes
•
Check with a network administrator about IP address. Do not set the duplicate IP address.
•
Set IP address on the External Device for IP address in Device-specific settings.
•
You need to set IP address on the Display in the off-line mode of the Display.
•
The default port No. of the PLC is 9600. For UDP connection, always perform the same settings for the port
No. of the Display and the External Device.
GP-Pro EX Device/PLC Connection Manual
14
CS/CJ Series Ethernet Driver
„ Setting of External Device
Double-click [I/O Table] in the project window to display the [PC I/O Table] window. Select [Unit Settings] from
the menu displayed by right-clicking on the Ethernet unit in the window to select the Ethernet Unit Setting Screen.
Setup Items
Settings
IP Address Conversion
Auto Creation Method (dynamic)
Line Speed
Auto Detection
IP Address
Option
*1
Source Network Address
Option
Node Address Setting Rotary Switch*2
Option
Unit No. Setting Rotary Switch*2
0
FINS/UDP Port
9600
*1
Parameter used when you access beyond network.
Set in the routing table of "CX-Net Network Configuration". Please refer to the manual of the External Device
for more details.
*2
Set with the rotary switch on the front of the Ethernet unit.
‹ Notes
•
•
Check with a network administrator about IP address and subnet mask. Do not set the duplicate IP address.
For UDP connection, always perform the same settings for the port No. of the Display and the External
Device.
GP-Pro EX Device/PLC Connection Manual
15
CS/CJ Series Ethernet Driver
3.4
Setting Example 4
„ Setting of GP-Pro EX
‹ Communication Settings
To display the setting screen, select [Device/PLC Settings] from [System setting window] in workspace.
• Set the optional network address of the Display in [Network].
• Set the optional node address of the Display in [Node].
GP-Pro EX Device/PLC Connection Manual
16
CS/CJ Series Ethernet Driver
‹ Device Setting
To display the setting screen, click
([Setting]) of External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
When you connect multiple External Device, click
from [Device-Specific Settings] of [Device/PLC
Settings] to add another External Device.
• Set the IP address you set for the External Device in [IP address].
• Set the network address you set for the External Device in [Network].
• Set the node address you set for the External Device in [Node].
‹ Notes
•
Check with a network administrator about IP address. Do not set the duplicate IP address.
•
Set IP address on the External Device for IP address in Device-specific settings.
•
You need to set IP address on the Display in the off-line mode of the Display.
•
The default port No. of the External Device is 9600. For UDP connection, always perform the same settings
for the port No. of the Display and the External Device.
GP-Pro EX Device/PLC Connection Manual
17
CS/CJ Series Ethernet Driver
„ Setting of External Device
To communicate GP and SYSMAC-CS1 Series (EtherNet Unit: CS1W-ETN21), CJ Series (EtherNet Unit:
CJ1W-ETN21), you need to set the EtherNet Unit of PLC.
Double-click [I/O Table] in the project window to display the [PC I/O Table] window. Select [Unit Settings] from
the menu displayed by right-clicking on the Ethernet unit in the window to select the Ethernet Unit Setting Screen.
Setup Items
Settings
IP Address Conversion
Auto Creation Method (dynamic)
Line Speed
Auto Detection
IP Address
Option
Source Network Address*1
Option
Switch*2
Option
*2
Unit No. Setting Rotary Switch
0
FINS/TCP Port
9600
Node Address Setting Rotary
*1
Parameter used when you access beyond network.
Set in the routing table of "CX-Net Network Configuration". Please refer to the manual of the External Device
for more details.
*2
Set with the rotary switch on the front of the Ethernet unit.
‹ Notes
•
Check with a network administrator about IP address and subnet mask. Do not set the duplicate IP address.
GP-Pro EX Device/PLC Connection Manual
18
CS/CJ Series Ethernet Driver
4
Setup Items
Set communication settings of the Display with GP-Pro EX or in off-line mode of the Display.
The setting of each parameter must be identical to that of External Device.
)"3 Example of Communication Setting" (page 7)
• Set the Display’s IP address in off-line mode.
Cf.
4.1
Maintenance/Troubleshooting Manual "2.5 Ethernet Settings"
Setup Items in GP-Pro EX
„ Communication Settings
To display the setting screen, select [Device/PLC Settings] from [System setting window] in workspace.
Setup Items
Setup Description
Port No.
For UDP connection, use an integer from 1024 to 65535 to enter the port No. of the
Display. For TCP connection, the port No. of the Display is fixed to "Auto Assign", and it
will be automatically assigned.
Timeout
Use an integer from 1 to 127 to enter the time (s) for which the Display waits for the
response from the External Device.
Retry
In case of no response from the External Device, use an integer from 0 to 255 to enter
how many times the Display retransmits the command.
Wait To Send
Use an integer from 0 to 255 to enter standby time (ms) for the Display from receiving
packets to transmitting next commands.
Source
Address
Network
Enter the network address of the Display, using 0 to 127.
Node
Enter the node address of the Display, using 1 to 254.
GP-Pro EX Device/PLC Connection Manual
19
CS/CJ Series Ethernet Driver
„ Device Setting
To display the setting screen, click
([Setting]) of External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
When you connect multiple External Device, click
from [Device-Specific Settings] of [Device/PLC
Settings] to add another External Device.
Setup Items
Setup Description
Set IP address of the External Device.
IP Address
• Check with a network administrator about IP address. Do not set the duplicate IP
address.
Enter the port No. of the External Device, using 1 to 65535.
Port No.
Destination
Address
• UDP connection: Do not use the port No. 53/123, which are reserved in the system.
• TCP connection: Do not use the port No. 20/21/25/53/110, which are reserved in the
system.
Network
Enter the network address of the External Device, using 0 to 127.
Node
Enter the node address of the External Device, using 1 to 254.
GP-Pro EX Device/PLC Connection Manual
20
CS/CJ Series Ethernet Driver
4.2
Setup Items in Off-Line Mode
• Refer to the Maintenance/Troubleshooting manual for information on how to enter off-line mode
or about the operation.
Cf.
Maintenance/Troubleshooting Manual "2.2 Off-line Mode"
„ Communication Settings
To display the setting screen, touch [Device/PLC Settings] from [Peripheral Settings] in off-line mode. Touch the
External Device you want to set from the displayed list.
Setup Items
Setup Description
Port No.
For UDP connection, use an integer from 1024 to 65535 to enter the port No. of the
Display. For TCP connection, the port No. of the Display will be automatically assigned
regardless of the entered value.
Timeout
Use an integer from 1 to 127 to enter the time (s) for which the Display waits for the
response from the External Device.
Retry
In case of no response from the External Device, use an integer from 0 to 255 to enter how
many times the Display retransmits the command.
Wait To Send
Use an integer from 0 to 255 to enter standby time (ms) for the Display from receiving
packets to transmitting next commands.
Network Address
Enter the network address of the Display, using 0 to 127.
Node Address
Enter the node address of the Display, using 1 to 254.
GP-Pro EX Device/PLC Connection Manual
21
CS/CJ Series Ethernet Driver
„ Device Setting
To display the setting screen, touch [Device/PLC Settings] from [Peripheral Settings]. Touch the External Device
you want to set from the displayed list, and touch [Device].
Setup Items
Device/PLC Name
Setup Description
Select the External Device to set. Device/PLC name is a title of the External Device set
with GP-Pro EX. (Initial value [PLC1])
Set IP address of the External Device.
IP Address
• Check with a network administrator about IP address. Do not set the duplicate IP
address.
Port No.
Enter the port No. of the External Device, using 1 to 65535.
Network Address
Enter the network address of the External Device, using 0 to 127.
Node Address
Enter the node address of the External Device, using 1 to 254.
GP-Pro EX Device/PLC Connection Manual
22
CS/CJ Series Ethernet Driver
5
Supported Device
Range of supported device address is shown in the table below. Please note that the actually supported range of
the devices varies depending on the External Device to be used. Please check the actual range in the manual of
your External Device.
This address can be specified as system data area.
Device
32
bits
Bit Address
Word Address
0000.00 - 6143.15
0000 - 6143
Internal Auxiliary Relay
W000.00 - W511.15
W000 - W511
Special Auxiliary Relay
A000.00 - A959.15
A000 - A959
Latch Relay
H000.00 - H511.15
H000 - H511
Timer (Time Up Flag)
T0000 - T4095
-
*3
Counter (Count Up Flag)
C0000 - C4095
-
*3
Timer (Current Value)
-
T0000 - T4095
Counter (Current Value)
-
C0000 - C4095
D00000.00 - D32767.15
D00000 - D32767
Extension Data Memory
(E0-EC)
E000000.00 - EC32767.15
E000000 - EC32767
Extension Data Memory
(Current Bank)
-
EM00000 - EM32767
Task Flag
(Bit)
TKB00 - TKB31
-
Task Flag
(Status)
TK00.00 - TK31.07
TK00 - TK30
*3
Index Register
-
IR00 - IR15
*7
Data Register
-
DR00 - DR15
*7
Channel I/O
Data Memory
Notes
*1
*2
*1
*4 *5
*6
*3
*1
Do not write in Channel I/O address 1500-1899 and Data Memory address D30000-D31599 from the
Display. Because those address are used for setting the system on the External Device.
*2
Write disable in A000 to A447.
*3
Write disable
*4
Max 13 bank (E0 to EC) can be used. 1 bank is 32768 words. Available bank number is different depending
on the CPU unit.
*5
CJM1 Series does not include the extension data memory (E0 to EC, current bank EM).
*6
CJ Series does not include the extension data memory (Current bank EM).
*7
Write disable during RUN
GP-Pro EX Device/PLC Connection Manual
23
CS/CJ Series Ethernet Driver
• Please refer to the GP-Pro EX Reference Manual for system data area.
Cf. GP-Pro EX Reference Manual "Appendix 1.4 LS Area (Direct Access Method)"
• Please refer to the precautions on manual notation for icons in the table.
) "Manual Symbols and Terminology"
GP-Pro EX Device/PLC Connection Manual
24
CS/CJ Series Ethernet Driver
6
Device Code and Address Code
Use device code and address code when you select "Device Type & Address" for the address type in data displays.
Device Name
Device Code
(HEX)
Channel I/O
-
0080
Word Address
Internal Auxiliary Relay
W
0082
Word Address
Special Auxiliary Relay
A
0085
Word Address
Latch Relay
H
0084
Word Address
Timer (Current Value)
T
0060
Word Address
Counter (Current Value)
C
0061
Word Address
Data Memory
D
0000
Word Address
Extension Data Memory
(E0-EC)
E0
0010
Word Address
E1
0011
Word Address
E2
0012
Word Address
E3
0013
Word Address
E4
0014
Word Address
E5
0015
Word Address
E6
0016
Word Address
E7
0017
Word Address
E8
0018
Word Address
E9
0019
Word Address
EA
001A
Word Address
EB
001B
Word Address
EC
001C
Word Address
Extension Data Memory
(Current Bank)
EM
0001
Word Address
Task Flag
(Status)
TK
0002
Word Address
Index Register
IR
0003
Word Address
Data Register
DR
0004
Word Address
Device
GP-Pro EX Device/PLC Connection Manual
25
Address Code
CS/CJ Series Ethernet Driver
7
Error Messages
Error messages are displayed on the screen of Display as follows: "No. : Device Name: Error Message (Error
Occurrence Area)". Each description is shown below.
Item
Description
No.
Error No.
Device Name
Name of External Device where error occurs. Device name is a title of External Device set
with GP-Pro EX.(Initial value [PLC1])
Error Message
Displays messages related to the error which occurs.
Displays IP address or device address of External Device where error occurs, or error codes
received from External Device.
Error Occurrence Area
• IP address is displayed as "IP address (Decimal): MAC address (Hex)".
• Device address is displayed as "Address: Device address".
• Received error codes are displayed as "Decimal [Hex]".
Display Examples of Error Messages
"RHAA035: PLC1: Error has been responded for device write command (Error Code: 2 [02H)"
• Refer to your External Device manual for details on received error codes.
• Refer to "When an error is displayed (Error Code List)" in "Maintenance/Troubleshooting Manual"
for details on the error messages common to the driver.
GP-Pro EX Device/PLC Connection Manual
26