- No category
advertisement
▼
Scroll to page 2
of 40
english H eating V entilation A ir conditioning New • Flush/wall-mounted room thermostats • Analogue clock thermostats • Digital clock thermostats • Radio-controlled thermostats • Actuators • 3 point controller • Mixer control • Service water control • Weather-dependent control • Open Therm • KNX heating control NEW PRODUCTS 2009 Digital clock thermostat with multi-function input RAMSES 832 top2 • Presence detector, window contact or floor sensor input • Flat housing (21 mm) • Backlit display • Text guidance CO2 sensor for climate control with 2 stage control, relay outputs + 0 – 10 V proportional outputs for CO2, temperature and relative humidity. 2 Analogue clock thermostats with daily and weekly programs Pages 10 – 11 Digital clock thermostats with daily and weekly programs with optimisation Wall installation with floor sensor with 3 point control with radio control Pages 12 – 14 Page 15 Pages 16 – 17 Page 18 Pages 19 – 20 Pages 21 – 23 Heating controller with service water control Pages 24 – 25 Digital clock thermostats Rail mounted Flush-mounted installation Connection diagrams Page 26 Page 27 Pages 28 – 29 Sensors CO2 sensors Humidity stat Page 30 Page 31 Digital time switches Wall-mounted, rail mounted Page 32 Timer switches Socket devices Page 33 Operating hours counter analogue/digital display Page 34 KNX heating control thermostats Pages 36 – 37 KNX actuators for fan coils for underfloor heating, rail mounted Page 37 Page 38 KNX actuators without control, with control thermal 24V/230 V~ Page 38 Page 39 Digital controllers Page 6 Page 7 Pages 8 – 9 Other Wall-mounted Flush-mounted installation Electronic room thermostats KNX Analogue room thermostats Analogue controllers Contents 3 Order number Page number Replacement device without front cover, order no. 701 0 001 P. 6 3/4 230 V 50 Hz • 702 0 001 P. 6 3/4 230 V 50 Hz • 703 0 001 P. 6 3/4 230 V 50 Hz • 704 0 001 P. 6 3/4 230 V 50 Hz • 705 0 001 P. 6 4/5 230 V 50 Hz • 706 0 001 P. 6 4/5 230 V 50 Hz • 707 0 001 P. 6 3/4 230 V 50 Hz • 708 0 001 P. 6 4/5 230 V 50 Hz • 709 0 001 P. 6 2/3 230 V 50 Hz • 741 0 130 741 0 131 P. 7 4/5 230 V 50 Hz • 746 0 130 746 0 131 P. 7 3/4 230 V 50 Hz • 748 0 130 748 0 131 P. 7 Heating 3/4 230 V 50 Hz • 714 0 002 P. 8 Heating Heating 6/7 230 V 50 Hz • 714 0 016 P. 8 • 714 0 017 P. 8 751 0 131 P. 9 Flush-mounted housing Operating voltage • Wall-mounted Connecting wires 230 V 50 Hz Display 2/3 Manual switch Temperature reduction input Underfloor temperature sensor Room temperature sensor Thermostats Temperature setting range Model comparison Analogue clock thermostats, wall-mounted RAMSES 701 5…30°C • RAMSES 702 5…30°C • RAMSES 703 5…30°C • RAMSES 704 5…30°C • RAMSES 705 5…30°C • RAMSES 706 5…30°C • RAMSES 707 5…30°C • RAMSES 708 5…30°C Heating/ cooling • RAMSES 709 5…30°C Heating/ cooling • • Additional Additional heating heating Heating • Heating Heating Heating + Additional Additional heating heating • Comfort reduction automatic Heating Analogue room thermostats, flush-mounted installation RAMSES 741 RA 5…30°C • RAMSES 746 RA 5…30°C • RAMSES 748 RA 5…30°C Heating/ cooling • • Heating Heating Electronic room thermostats, wall mounted/ flush-mounted • RAMSES 714 5…30°C RAMSES 714 A 10…30°C • RAMSES 714 A/FH 5…30°C • Heating Heating 6/7 230 V 50 Hz RAMSES 751 RA 10…30°C • Heating Reduction 6/7 230 V 50 Hz • • Accessories: Actuators for individual room control 4 ALPHA 4 230 V~ Actuator suitable for all RAMSES controllers. Opens without current. Humidity and overload protection. Plug-in 907 0 438 installation plus well as function and adjustment control. Valve adapter required). P. 39 ALPHA 4 24 V Positioning actuator as before, but for 24 V AC/DC low voltage. SELV with use of an isolating transformer e.g. for bathrooms and sanitary facilities P. 39 907 0 439 (Hand adjustment range) 3/4 Segment 722 0 801 Prog. 24 h 782 0 801 P. 10 - 11 1 5/30 min Day tappet 15 min I Battery 365 d (Hand adjustment range) 3/4 Segments 5k reduc- 784 0 030 784 0 801 tion P. 10 - 11 6…30°C 1 5/30 min Day tappet I 230 V~ 3d (Hand adjustment range) 3/4 Reduction 721 0 030 control 725 0 030 only P. 10 - 11 24 h/ 7d 6…30°C 3 I 230 V~ battery ± 1 h auto 3/4 2 24 h/ 7d 6…30°C 230 V~ battery ± 1 h auto 3/4 2 RAMSES 722 S RAMSES 782 S 24 h 6…30°C 1 15 min RAMSES 784 RAMSES 784 S 24 h/ 7d 6…30°C RAMSES 721 RAMSES 725 24 h RAMSES 812 top2 RAMSES 811 top2 RAMSES 832 top2 RAMSES 831 top2 Memory locations Day tappet Page number 230 V~ 3d 5 min 30 mins Order number Connection for operating devices (wires) I 1 Special functions Automatic summer/winter time Segments 6…30°C TR top text guidance P. 10 - 11 24 h/ 7d Manual switch Changeover range 722 0 030 Prog. 24 h 782 0 030 /7d Programmable every … 3/4 Quantity Switching programs (Hand adjustment range) Room temperature setting range Operating voltage Power reserve Switching program I 230 V~ 3d RAMSES 722 RAMSES 782 Clock thermostats Analogue Clock thermostat Digital clock thermostats 1 min. 24 Mains 812 0 132 Battery 811 9 132 Illuminated display 5 temp. controls 3 indiv. programs 832 0 132 I 831 9 132 The world's finite natural resources make it essential to3/4use ener812 0 032 RAMSES 812 top 24 h/ 6…30°C 230 V~ ± 1 h 22 1 min. 3 I 7d battery auto RAMSES 811 top gy responsibly. Therefore, saving energy is a top priority2 for The-811 9 032 832 0 032 3/4 RAMSES 832 top 24 h/ 6…30°C 230 V~ ± 1 h 3 of1 min. I ben all its22products and alsoauto for all other 7d RAMSES 831 topin the development battery 831 9 032 2 818 0 035 ± 1 h 24 h/ company 230 V~ innovative, activities of the and Our func6…30°C 1 min. its22employees. RAMSES 818 top 5/6 3 I 7d auto 818 0 036 5h tional and high quality systems for timing, lighting and air condi816 9 032 RAMSES 816 top 230 V~ ± 1 h 24 h/ 6…30°C 2 (Bus) 22 1 min. 3 I 7d RAMSES 817 top auto 5h 817 9 032 tioning are designed to help users save energy and money. 3 1 min. 24 Mains Battery 24 h/ 7d ± 1 h auto 3/4 2 Remote sensor for underfloor heating 6 A/16 A P. 18 Flushmounted installation 822 0 031 22 1 min. 3 I 823 0 031 »Energy saving ideas« – This brochure provides good examples RAMSES top 820 9 011 of820our active 24commitment to the22issues of energy, environmental 2 ± 1 h h/ 6…30°C Battery 3 1 min. I 7 d auto 821 9 011 2 RAMSES 821 top awareness and responsibility. RAMSES 823 top 6…30°C P. 16 P. 17 Ext. sensor 230 V~ 5h P. 12 - 14 5 temp. controls 3 indiv. programs 3 point control or 2 stages RAMSES 822 top P. 12 - 14 Wall installation Flushmounted installation Wall installation P. 19 - 20 P. 27 P. 27 Digital clock thermostat with radio control RAMSES 813 top2 HF Set AChairman / Set S Thomas Goes247 dh/ of the Board 6…30°C 3 1 min. 24 RAMSES 833 top2 HF Set 1/ Set 2 24 h/ 7d 6…30°C 3 1 min. RAMSES 813 top HF Set A / Set S 24 h/ 7d 6…30°C 3 RAMSES 813 top HF Set 1/ Set 2 24 h/ 7d 6…30°C 3 I Battery ± 1 h auto wireless Receiver Wall-mounted Intermediate connector 24 I Battery ± 1 h auto wireless 1 zone 2 zones 833 9 501 833 9 502 P. 15 1 min. 22 I Battery ± 1 h auto wireless Receiver Wall-mounted Intermediate connector 813 9 403 813 9 405 P. 21 1 min. 22 I Battery ± 1 h auto wireless 813 9 503 813 9 505 1 zone 813 9 401 2 zones 813 9 402 P. 15 P. 22 - 23 Heating control, weather or room temperature dependent with service water control RAMSES 855 top 24 h/ 7d 6…30°C 3 1 min. 22 I 5h ± 1 h auto 2 (Bus) 4 channel controller Service water control Circulation control Mixer control 855 9 032 P. 24 RAMSES 855 top2 OT 24 h/ 7d 6…30°C 3 1 min. 24 I 5h ± 1 h auto 2 (Bus) 4 channel controller Service water control Circulation control Mixer control 855 9 132 P. 25 5 Wall-mounted Room thermostats 5-30 °C Analogue controllers Function: Room thermostat with thermal recirculation, suitable for all heating types, e.g. gas, water, electric heating with central/ individual room controls. • Setting controller from +5 °C to +30 °C with mechanical setting limit or detection • RAM 708/709 is also suitable for air conditioning devices RAMSES 701 RAMSES 702 • Integrated temperature reduction (approx. 4 K) possible via external control (e.g. timer SYN 161 h, TR 610 top) possible. RAMSES 701 RAMSES 703 as RAMSES 702, but with internal setting • Temperature cannot be set externally. Temperature is set inside the device at start-up Technical data: Operating voltage: 230–240 V~, +10 %/–15 %, 50–60 Hz NC contact: 10 (4) A, 230 V~max. 10 Theben actuators -can be controlled (see page 39) Two-way switch: 10 (4) A (heating), max. 10 Theben actuators can be controlled (see page 39), 5 (2) A (cooling) Temperature range: +5 °C... +30 °C Switching differential, dynamic: approx. 1 K, thermal recirculation Protection class: II in accordance with EN 60730-1 subject to designated installation Protection rating: IP 30 in accordance with EN 60529 Housing colour: pure white (RAL 9010) Test approvals: V Weight: Approx. 80 g Connection diagrams see page 29. RAMSES 704 • Switch for additional heating ON/OFF+indicator lamp RAMSES 705 • Switch for heating ON / OFF RAMSES 706 • Integrated temperature reduction (approx. 4 K) possible via external control (e.g. timer) • Switch for heating ON / OFF + indicator lamp RAMSES 706 RAMSES 707 • Switch for heating ON / OFF • Switch for additional heating ON / OFF+indicator lamp RAMSES 708 • Heating / cooling two-way switch RAMSES 709 • Heating / cooling two-way switch • 3-way selector switch for: Comfort operation, reduced operation, external reduction (time-controlled with timer) • Indicator lamp RAMSES 707 70,7 Dimensional diagrams 75 5,5 24 28 83 11,5 Adapter plate for flush-mounted socket Type Operating voltage Temperature range r/ m Nominal current at 230 V~ Order no. RAMSES 701 230 V/50–60 Hz +5 °C to +30 °C 1 K 2-/3 conductors RAMSES 702 230 V/50–60 Hz +5 °C to +30 °C 1 K 3/4 way conductors 1 NC contact 10 (4) A 701 0 001 1 NC contact 10 (4) A RAMSES 703 230 V/50–60 Hz +5 °C to +30 °C 1 K 702 0 001 3-/4 conductors 1 NC contact 10 (4) A RAMSES 704 230 V/50–60 Hz +5 °C to +30 °C 1 K 703 0 001 3/4 way conductors 1 NC contact 10 (4) A 704 0 001 Switching differential Connection Contact dynamic approx. RAMSES 705 230 V/50–60 Hz +5 °C to +30 °C 1 K 3/4 way conductors 1 NC contact 10 (4) A 705 0 001 RAMSES 706 230 V/50–60 Hz +5 °C to +30 °C 1 K 4/5 way conductors 1 NC contact 10 (4) A 706 0 001 RAMSES 707 230 V/50–60 Hz +5 °C to +30 °C 1 K 4/5 way conductors 1 NC contact 10 (4) A 707 0 001 RAMSES 708 230 V/50–60 Hz +5 °C to +30 °C 1 K 3/4 way conductors 1 two-way switch 10 (4) A/5 (2) A 708 0 001 RAMSES 709 230 V/50–60 Hz +5 °C to +30 °C 1 K 4/5 way conductors 1 two-way switch 10 (4) A/5 (2) A 709 0 001 Adapter plate for flush mounted socket 79 x 79 mm 6 907 0 480 Flush-mounted Room thermostats 5-30 °C RAMSES 746 RA (with frame) Technical data: Operating voltage: 230–240 V~, +10 %/–15 %, 50–60 Hz NC contact: 10 (4) A, 230 V~max. 10 Theben actuators -can be controlled (see page 39) Two-way switch: 10 (4) A (heating), max. 10 Theben actuators can be controlled (see page 39), 5 (1) A (cooling) Temperature range: +5 °C... +30 °C Switching differential, dynamic:approx. 0.5 K, thermal recirculation Electrical connection: screwless terminals for 2 x (1.5 mm2–2.5 mm2) wire Protection class: II in accordance with EN 60730-1 subject to designated installation Protection rating: IP 30 in accordance with EN 60529 (with cover, installed) Housing colour: pure white gloss (RAL 9010) Test approvals: V Weight: Approx. 80 g RAMSES 741 • NC contact 50 RAMSES 746 • NC contact • Integrated temperature reduction (approx. 4 K) possible via external control (e. g. timer) • Switch for heating ON / OFF + indicator lamp Analogue controllers Function: Room temperature with thermal recirculation for installation in flush-mounted sockets. Ideal control for modernisation and new build projects as it is easy to integrate and fits in perfectly in the domestic environment. • Setting range +5 °C to +30 °C • Ability to limit temperature range using the control knob • Simple connection via screwless terminals • Available as replacement device without frame, cover plate and setting button, incl. protective cap • Frame, central part and setting button available as accessories • Central part (50 x 50) fits in nearly all programs via switch manufacturers adapter frame Flush mounted digital timer see main catalogue. Connection diagrams see page 29. RAMSES 748 • Heating / cooling two-way switch RAMSES 746(without cover, rotary switch and frame)replacement device for area switch programs Central part with switch section and setting button Frame Dimensional diagrams 80,5 70,6 50 24,5 60 56 56 50,5 19 für Gerätedose nach DIN 49073 Temperature range adjustabler/ m 19 für Gerätedose nach DIN 49073 60 Type Front Operating voltage 24,5 50,5 43,5 70,6 Central part without switch section and setting button Switching differential Connection Contact dynamic approx. Nominal current at 230 V~ Order no. RAMSES 741 Without cover 230 V/50–60 Hz +5 °C to +30 °C 0,5 K 3/4 conductors 1 NC contact 10 (4) A 741 0 130 RAMSES 746 Without cover 230 V/50–60 Hz +5 °C to +30 °C 0,5 K 4-/5 conductors 1 NC contact 10 (4) A 746 0 130 RAMSES 748 Without cover 230 V/50–60 Hz +5 °C to +30 °C 0,5 K 3/4 way conductors1 two-way switch 10 (4) A/5 (1) A 748 0 130 RAMSES 741 RA With cover 230 V/50–60 Hz +5 °C to +30 °C 0,5 K 2/3 way conductors1 NC contact 10 (4) A 741 0 131 RAMSES 746 RA With cover 230 V/50–60 Hz +5 °C to +30 °C 0,5 K 4-/5 conductors 10 (4) A 746 0 131 RAMSES 748 RA With cover 230 V/50–60 Hz +5 °C to +30 °C 0,5 K 3/4 way conductors1 two-way switch 10 (4) A/5 (1) A 748 0 131 1 NC contact Central part with switch section + setting button for RAMSES 746 907 0 601 Central part without switch section + setting button for RAMSES 741 and RAMSES 748 907 0 602 Frame 907 0 603 7 Wall-mounted Electronic room thermostats 5-30 °C Analogue controllers Function: Modern designed electronic room thermostats can easily be exchanged for currently installed thermostats. Surface mounting or directly on a flush mounted housing; also suitable for large area switching programs. Depending on the make an adapter plate (79 x 79 mm) may be required to completely cover the flush mounted housing. Technical data: Operating voltage: 230 V, +10 %/–15 %, 50 Hz Protection class: II in accordance with EN 60730-1 subject to designated installation Protection rating: IP 20 Housing colour: pure white (RAL 9010) RAMSES 714: Setting range: +5 °C…+30 °C Control accuracy: ± 0.25 K NC contact: 8 A/230 V~ RAMSES 714 • Precise electronic two point controller suitable for all types of heating, e. g. gas, water, electric heating etc. • Individual room control is possible in combination with Theben actuators • Exact temperature setting in the range of +5 °C…+30 °C • Heating status display via LED • Integrated temperature reduction (approx. 3.5 K) possible via external control (e. g. timer SYN 160 a, TR 610 top). Temperature reduction can be cut to 2 K by opening a wire bridge RAMSES 714 RAMSES 714 A: Setting range: +10 °C…+60 °C Control accuracy: ± 0.5 K Sensor cable: Length 4 m, Ø 6 mm, (IP 54) NC contact: 16 A/230 V~ RAMSES 714 A/FH: Setting range: +5 °C…+30 °C (+40 °C) Control accuracy: ± 0.5 K Sensor cable: Length 4 m, Ø 6 mm, (IP 54) NC contact: 16 A/230 V~ RAMSES 714 A Precise electronic on/off controller as with RAM 714 but including • External temperature sensor for under-floor heating (wet rooms or bathroom heating) • Switchable for the connection of available NTC sensors (33 KΩ/25 °C) • Setting range of +10 °C…+60 °C • Switch for heating ON / OFF • Sensor cable (IP 54), length 4 m RAMSES 714 A 10–60 °C Connection diagrams see page 29. RAMSES 714 A/FHas RAM 714 A but • Equipped with selectable underfloor heating temperature limits 40 °C (tiles) or 30 °C (laminates, wood, cork) • No switch to available NTC sensors • Setting range of +5 °C…+30 °C (+40 °C) RAMSES 714 A/FH Dimensional diagrams � 74 � 74 � 74 5 5 23.3 28 28 Type Operating voltage � 79 5 23.3 RAMSES 714 Combining the aforementioned clock thermostats with Theben actuators enables convenient, needs-driven individual room control. The actuators are simply screwed onto the individual radiators or into the heating circuit distributor in underfloor heating systems. � 67 � 67 � 67 Individual room control � 79 � 79 7.5 7.5 7.5 See page 39 for a detailed description. 27.9 32.6 RAMSES 714 A Adapter plate for flush-mounted socket Temperature Connection Contact ranger/ m Nominal current at 230 V~ RAMSES 714 230 V/50 Hz +5 °C to +30 °C 2/3 way conductors 1 NC contact 8 A RAMSES 714 A 230 V/50 Hz +10 °C bis +60 °C 4/5 way conductors 1 NC contact 16 A RAMSES 714 A/FH230 V/50 Hz +5 °C to +30 °C (+40 °C) 4/5 way conductors 1 NC contact 16 A Adapter plate for flush mounted socket 79 x 79 mm 8 Order no. 714 0 002 714 0 016 714 0 017 907 0 212 Flush-mounted Electronic room thermostat Technical data: Operating voltage: 230 V~, +10 %/–15 %, 50 Hz NO contact: 16 (4) A, 230 V~ Setting range: +10 °C…+50 °C Control behaviour: Proportional controller with PWM (continuous type) Sensor cable: Length 4 m, diameter 6 mm, extendable to 50 m Displays: LED red – controller demands heat LED green – reduced mode Protection class: II in accordance with EN 60 529 Protection rating: IP 30 Housing colour: pure white (RAL 9010) Analogue controllers RAMSES 751 RA Precise electronic controller (PWM) with remote temperature sensor for floor temperature control. • Ideal controller for underfloor heating • Floor temperature setting range +10 °C…+50 °C • Temperature limitation and detection using the setting button • Temperature reduction option (3 or 5 K) via external timer or switch • Display of temperature reduction and heating ON • 2-pole mains switch for heating ON/OFF • Emergency mode for sensor malfunction at 30 % heating • Connection via screw terminals • Central part fits nearly all frames using an adapter frame from the switch manufacturer RAMSES 751 RA L N 10–50 °C L N S1 N Sensor Sonde TA RAMSES 751 RA Dimensional diagrams Individual room control 80,5 70,6 45 4 17 3 Combining the aforementioned clock thermostats with Theben actuators enables convenient, needs-driven individual room control. The actuators are simply screwed onto the individual radiators or into the heating circuit distributor in underfloor heating systems. 28 2 5 56 50 See page 39 for a detailed description. 60 für Gerätedose nach DIN 49073 Type Operating voltage Temperature Connection Contact range Nominal current at 250 V~ Order no. RAMSES 751 RA +10 °C…+50 °C 16 (4) A 751 0 131 230 V/50 Hz 6/7 way conductor NO contact 9 Wall-mounted Analogue controllers Analogue clock thermostats RAMSES 721 RAMSES 722/782/784 10-30 °C 7d 24 h Function: Clock thermostats in a low profile design for time-dependent monitoring and control of room temperature. Easy setting of energy saving temperature reduction at night on program disc. 24 h segmented timing disc ("S" type) or optional switchable timing disc for 24 h or 7 days. Suitable for oil or gas fired heating systems. The clock thermostat controls recirculation pump, thermal actuator, magnetic valve, motorised mixer or the gas water heaters directly via relay contact. RAMSES 722, clock thermostat in a low profile design for time-dependent monitoring and control of room temperature. • Electronic temperature control • Operating point and electronic recirculation are set from the front • Normal and reduction temperature are set separately, range +10 °C ... +30 °C • Party switch and program display • Selector switch for operating mode: m Constant reduction temperature r Constant normal temperature j Automatic mode f Frost and plant protection +6 °C • Synchronous motor drive • Two way switch 6 (1) A/250 V~ RAMSES 782, as RAMSES 722, except for • Quartz mechanism, 3 day power reserve RAMSES 784 S with opened flap and segment program disc Tappet program disc Set handto 16.00... RAMSES 784, as RAMSES 782, except for • Batteries for 2 or 3 wire connection • Battery monitoring with battery replacement indicator via flashing LED • Silting and pump protection function (option) RAMSES 721, as RAMSES 722, except for • 24 h tappet timing disc • Normal temperature range from +10 °C...+30 °C • Reduced temperature approx. 5 K lower in relation to the set comfort temperature • No selector switch for operation mode RAMSES 725, as RAMSES 722, except for • Comfort temperature control through existing thermostat valves on radiator • Temperature reduction controlled centrally through RAM 725 within the range of +10 °C - +30 °C in accordance with switching program • Selector switch for 4 operating modes Technical data: Clock thermostats are a combination of a timer and a thermostat (on/off controller). Tappets or segments make it possible to reduce temperature several times a day. Segment program disc: 24 hour program, programmable every 15 mins, shortest switching interval 15 mins Tappet program disc: Adjustable for 24 hour and 7 day programs. 24 hr program: Programmable every 5 mins, shortest switching interval 20 mins 7 day program: Programmable every 30 mins, shortest switching interval 2 hours Time adjustment: via analogue time display, including anti-clockwise. Thermostat: On/off controller, setting range +10 °C...+30 °C, frost protection +6 °C, operating point (± 4 K) Switching differential can be adjusted via electronic recirculation: 0.4–1.2 K (4...20 mins) Type RAM 721/725: fixed 1.5 K (20 mins) Contact: Two way switch, opening width less than 3 mm (µ), floating, not for SELV Switching capacity: 6 (1) A/250 V~ Protection rating: IP 20 in accordance with EN 60 529 Protection class: II in accordance with EN 60 730-1 subject to designated installation Test approvals: national and internationaldepending on type of device V (RAMSES 721/722/725/782) Housing dimensions: 90 x 150 x 35 mm RAMSES 722/721/725 without power reserve Operating voltage: 230 V~, +10 %/-15 % Frequency: 50 Hz Time accuracy: Dependent on mains frequency RAMSES 782 with power reserve Operating voltage: 230 V~, +10 %/-15 % Frequency: 50-60 Hz Time accuracy: ≤ ± 1 s/day at 20 °C RAMSES 784 with battery operation Operating voltage: 2 AA batteries Time accuracy: ≤ ± 1 s/day at 20 °C Contact: Two way switch, opening width less than 3 mm (µ), floating, suitable for SELV ... Remove graduated ring ... Actuator for individual room control see page 39. ... turn overand clip into weekly program. Red tappetsfor normal temperature, blue tappets for reduced temperature 10 Tappets: red: switches on normal temperature Order no. 934 3 236 blue: switches on reduction Order no. 934 3 111 Wall-mounted Analogue clock thermostats 1 2 3 1 2 3 M 4 5 M + L N RAMSES 7.. controls recirculation pump, thermal mixer valve or oil/gas burners RAMSES 7.. controls motorised mixer valves 60 1 2 3 L N RAMSES 784 controls recirculation pump, thermal mixer valve or oil/gas burners RAMSES 784 controls motorised mixer valves I j ±1h Flush-mounted socket or wall installation + L N Functions and plug-in base connection, e.g. RAM 722 s/782 s - 4 5 L N 1 2 3 Analogue controllers 10-30 °C 7d 24 h Control lamp for heating mode Program display and party switch can be switched by hand to normal or reduce temperature early - Normal temperature controllerfor setting r comfortable room temperature m Energy saving controller for setting reduction temperature, e.g. at night Time display withadjustable hands for summer/ winter-time correction R N Switching differential adjustable Selector switch for operating modes j Automatic program r continuous normal temperature m continuous reduced temperature f Frost and plant protection ( +6 °C) Operating point adjustable Type RAMSES 722 RAMSES 722 S RAMSES 782 RAMSES 782 S Power reserve approx. Temperature ranger/ m Switching Connection* Contact Display Program differential adjustable Order no. +10 °C to +30 °C +10 °C to +30 °C +10 °C bis +30 °C +10 °C bis +30 °C 0,4–1,2 K 0,4–1,2 K 0,4–1,2 K 0,4–1,2 K 3 or 4 conductors 3 or 4 conductors 3 or 4 conductors 3 or 4 conductors 1 LED Heating 1 LED Heating 1 LED Heating 1 LED Heating 24 h/7 d tappet 24 h segments 24 h/7 d tappet 24 h segments 722 0 030 722 0 801 782 0 030 782 0 801 RAMSES 784 1 year +10 °C bis +30 °C 0,4–1,2 K monitoring 2 or 3 conductors 1 two-way switch 1 LED Battery 24 h/7 d tappet 784 3 030 RAMSES 784 S 1 year +10 °C bis +30 °C 0,4–1,2 K monitoring 2 or 3 conductors 1 two-way switch 1 LED Battery 24 h segments 784 0 801 3 or 4 conductors 1 two-way switch – 24 h tappets 721 0 030 3 or 4 conductors 1 two-way switch 1 LED Heating 24 h/7 d tappet 725 0 030 RAMSES 721 RAMSES 725 – – 3 days 3 days – +10 °C to +30 °C r fixed 1.5 K –B5Km – reduction range fixed 1.5 K +10 °C bis +30 °C 1 two-way switch 1 two-way switch 1 two-way switch 1 two-way switch Wallpaper/ wall cover plate for replacement of RAM 3... devices by new clock thermostats such as RAM 722... * Terminals 2 and 4 can be bridged if only one 3-wire cable has been laid. In this case the clock mechanism of the thermostat stops when the heating system is switched off in the summer. If more than 3 wires are laid it is possible to provide a separate voltage supply to the clock thermostat from another external wire. 907 0 245 11 all in one RAMSES 800 top2 series for wall installation CO2 savings – Cut heating costs – Increase living comfort Digital controllers RAMSES 832 top2 digital clock thermostat Plain text operator guidance on screen New Backlit display Versatile due to ECO or party programs Easy plug-in installation Drill holes suitable for previous RAMSES 800 models 12 Rotary control: warmer / cooler Room temperature control with radio control is ideal for retrofitting. The installation of a radio clock thermostat does not create any disruption. There is no need to lay new cables in the property. The controller can also be sited on a shelf or desk if no suitable location such as tiles in the bathroom is available. There is now no reason to do without energy-saving room temperature control. BELISK P¡ family WINDOW CONTACT P™ SINGLES P£ SHIFT WORK P¢ pERM COMFORT TELEPHONE CONTACT PRESENCE DETECTOR FLOOR SENSOR P∞ PERM REDUCTION Digital controllers The new RAMSES generation is elegant, convenient and cost effective. The "all in one" solution makes it suitable for almost any application. This makes it the right device for the service vehicle. OPTIMISATION FUNCTION HOLIDAY PROGRAM LOCK KEYPAD WALL COMPENSATION ETC P§ FROST PROTECT Always have the right program to hand. Or you can set up the one you need. All preset programs can be customised - time and temperature. All in one means: – A window contact can be connected to an external input to take account of ventilation phases – The heating in a holiday home can be remotely controlled via a telephone switching input Achieve additional comfort by: – Optimisation: It automatically corrects the heating start up so that the comfort temperature is reached earlier – Date-controlled holiday program with reduction phase or heating phase for holiday homes for example An optional floor sensor for underfloor heating or a remote sensor for publically accessible rooms, for example, can be connected to an external input. Designed for controlling circulation pumps, gas water heaters, burners, heating circuit distributors with actuators or electrical underfloor heating. or Radio It doesn't matter if it's new build, replacement or upgrading as the 2 or 3 wire connection or radio technology always provide a solution to satisfy the customer. 13 Wall-mounted Digital clock thermostat New Digital controllers RAMSES 812 top2 (mains version) RAMSES 811 top2 (battery version) 6-30 °C 7d 24 h Optimisation Holiday ±1h auto STANDARD SERIES RAMSES 812 top2, mains version • Digital clock thermostat in elegant, flat, whitedesign perfectly suits modern decor • Suitable for energy-saving room temperature controlin houses, apartments, heating zones,offices, showrooms, factories, medical practices • Quick and simple operation using rotary switch for temperature • INFO key for viewing important settings • Easy-to-read text line in the display provides a step-bystep guide to programming • Optimal adaptation thanks to operating point andswitching differential setting option • Fast set-up through 3 individually adjustable basic programs with adjustable comfort, reduction temperatures1st program for families with heating reduction at night2nd program for singles, heating reduction during working hours and at night3rd program for shift workers • 24 programmable switching times with a maximum of 4 temperature levels • Comfort and reduced temperature adjustable over range of +10 °C– +30 °C • Frost protection over range of +6 °C– +10 °C • Time-limited Party/ECO programs for comfort or reduced temperature • Fully automatic summer/winter-time correction • Power reserve approx. 3 hours in event of loss of mainssupply • Child lock or lock for publically-accessible rooms • Pump protection function in summer months - 3 or 4-wire connection in base • Plug-in base for wall or flush-mounted socket installation RAMSES 811 top2, battery version • Digital clock thermostat as before except for2 or 3 wire connection • Voltage supply from2 x 1.5 V AA batteries • Bar display for battery capacity with battery replacement indicator COMFORT SERIES RAMSES 832 top2, mains version, as before except for: • Illuminated display through keystroke • External input for connection of presence detectors, remote sensors, floor sensors, window contacts or telephone remote switches • Fast start-up thanks to factory preset time and date • 24 programmable switching times with 3 comfort temperature levels, reduction stage • Optimisation function for automatic correction of heating start to enable comfort temperature to be achieved more quickly • Holiday program with reduction phase or date-controlled heating phase for holiday homes, for example RAMSES 831 top2 (battery version) RAMSES 832 top2 (mains version) New RAMSES 831 top2, battery version • 2 or 3-wire connection Type Features Operating voltage Temperature range r/ m/f Control Contact accuracy Common technical data: Mode of operation: Type 1 B in accordance with EN 60730-1 Switch load: Max. 6 (1) A 250 V, min. 1 mA 5 V... Contact material: AgSnO2 Contact: Two-way switch, floating, electrically isolated Time accuracy: 1 s/day at 20 °C Time based on: Quartz Control accuracy: ≤ ± 0,2 ° Temperature display: accurate to 0.1 °C Temperature setting range: +6 °C...+30 °C in 0.2 degree increments Control type options: Pulse width modulation or hysteresis controller Control period: 5…30 mins Control capture range: ± 0.2 K..5 K Protection class: II in accordance with EN 60 730-1 Protection rating: IP 20 in accordance with EN 60529 RAMSES 812 top2/ 832 top2 Operating voltage: 230 V, ± 10 % Frequency: 50 Hz Power reserve: Approx. 5 hours, permanent heating operation in the event of power failure RAMSES 811 top2/ 831 top2 Operating voltage: Battery operation,2 x 1.5 V AA alkaline batteries Battery life: approx. 1 year, depending on switching frequency Battery replacement time: Max. 10 min. with no loss of time Connection examples: 6 8* 7 RAMSES 832 top2 controls circulation pump or actuator 8* 7 T1 T2 L N RAMSES 831 top2 controls burners or gas water heaters * Input for telephone control Nominal current at 250 V~ Order no. RAMSES 812 top2 230 V/50 Hz 24 h/7 d pure white RAL 9010 Holiday proRAMSES 811 top2 gram 2 x 1.5 V AA pure white RAL 9010 +10 °C...+30 °C ≤ ± 0,2 K 1 two-way switch 6 (1) A 811 9 132 (Available from Sept. 2009) +6 °C...+10 °C frost protection RAMSES 832 top2 24 h/7 d 230 V/50 Hz Holiday program pure white RAL 9010 +10 °C...+30 °C ≤ ± 0,2 K 1 two-way switch 6 (1) A 832 0 132 (Available from Sept. 2009) +6 °C...+10 °C frost protection RAMSES 831 top2 Optimisation 2 x 1.5 V AA Ext. input pure white RAL 9010 +10 °C...+30 °C ≤ ± 0,2 K 1 two-way switch 6 (1) A 831 9 132 (Available from Sept. 2009) +6 °C...+10 °C frost protection Illuminated display 14 +10 °C...+30 °C ≤ ± 0,2 K 1 two-way switch 6 (1) A 812 0 132 (Available from Sept. 2009) +6 °C...+10 °C frost protection Wall-mounted REC 21 receiver (Set S) Operating voltage: Battery operation, 2 x 1.5 V AA alkaline batteries Battery life: approx. 1 year, depending on switching frequency Battery replacement time: Max. 10 min. with no loss of time Transmission frequency: 868 MHz Transmission power: Less than 10 mW Emergency function: In the event of power or transmission failure Heating mode Time accuracy: 1 s/day at 20 °C Time based on: Quartz Control accuracy: ≤ ± 0,2 ° Temperature display: accurate to 0.1 °C Temperature setting range: +6 °C... +30 °C in 0.2 degree increments Protection class: II in accordance with EN 60 730-1 Protection rating: IP 20 in accordance with EN 60529 Dimension diagram: RAMSES 813 top2 HF, Set S, 1 zone control Consisting of 1 RAMSES 813 top2 HF clock thermostat and 1 REC 21 receiver as grounding intermediate connector (16(2) A) e.g. for towel rails or radiators/fan heaters. New REC 1 (Set 1) REC 2 (Set 2) COMFORT SERIES RAMSES 833 top2 HF (radio version) as RAMSES 813 top2 HF, except for the addition of: • External input for connection of presence detectors, remote sensors, floor sensors, window contacts or telephone remote switches • Fast start-up thanks to factory preset time and date • Illuminated display through keystroke • 24 programmable switching times • Optimisation function 65,5 60 90 RAMSES 833 top2 HF, Set 1, 1 zone control Consisting of 1 RAMSES 833 top2 HF clock thermostat and a receiver with a two way switch, 6 (2) A/250 V, for rail/wall installation (5 temp. levels) 128* RAMSES 833 top2 HF (radio version) 23 140 125* 55* RAMSES 833 top2 HF, Set 2, 2 zone control Consisting of 2 RAMSES 833 top2 HF clock thermostats and a 2 channel receivers with 2 two way switches, 6 (2) A/250 V, for rail/wall installation (5 temp. levels) Clock thermostat Type Programs Temperature Switching differen-Connection range r/ m/f tial adjustable Receiver Nominal Contact Nominal current voltage RAMSES 813 top2 HF 24 h/7 days +6 °C bis +30 °C ± 0.2 K wireless Set A Holiday program Frost protection 230 V 50/60 Hz 1 NO contacts RAMSES 813 top2 HF 24 h/7 days +6 °C bis +30 °C ± 0.2 K wireless Set S Holiday program Frost protection 230 V 50/60 Hz 1 NO contacts RAMSES 833 top2 HF 24 h/7 days +6 °C bis +30 °C ± 0.2 K wireless Set 1 Holiday program Frost protection 230 V 50/60 Hz 1 two-way switch RAMSES 833 top2 HF 24 h/7 days +6 °C bis +30 °C ± 0.2 K wireless Set 2 Holiday program Frost protection 230 V 50/60 Hz 2 two-way switch 16(2) A/250 V~ Order no. 813 9 503 (Available from Sept. 2009) 16(2) A/230 V~ 813 9 505 (Available from Sept. 2009) 6 (1) A 833 9 501 (Available from Sept. 2009) UHF rod antenna for 868 MHz with wall holder and 2 m screened connection cable (required only for unfavourable reception quality). Terminal box cover plate for the receiver is included in the scope of supply. 6 (1) A 833 9 502 (Available from Sept. 2009) 907 0 334 15 Digital controllers REC 11 receiver (Set A) RAMSES 813 top2 HF, Set A, 1 zone control Comprising 1 RAMSES 813 top2 HF and an REC 11 receiver with a NO contact, 16 (2) A/250 V, for wall-mounting Common technical data: 45 New STANDARD SERIES RAMSES 813 top2 HF (radio version) • INFO key for viewing important settings • Easy-to-read text line in the display provides a step-bystep guide to programming • Optimal adaptation thanks to operating point andswitching differential setting option • 24 programmable switching times with a maximum of 4 temperature levels • Comfort and reduced temperature adjustable over range of +10 °C– +30 °C • Frost protection over range of +6 °C– +10 °C • Time-limited Party/ECO programs for comfort or reduced temperature • Fully automatic summer/winter-time correction • Power reserve approx. 3 hours in event of loss of mains supply • Child lock or lock for publically-accessible rooms • Pump protection function in summer months - 3 or 4-wire connection in base • Plug-in base for wall or flush-mounted socket installation 7d 24 h Holiday ±1h auto 95 RAMSES 813 top2 HF (radio version) 6-30 °C 80 Digital clock thermostat with radio control Wall-mounted Digital clock thermostat Digital controllers RAMSES 812 top (mains version) RAMSES 811 top (battery version) 6-30 °C RAMSES 812 top, mains version • Digital clock thermostat in outstanding, flat, functional design can easily be integrated into any environment • The external design can be adapted to suit any taste or fashion through different coloured housing covers • Suitable for energy-saving room temperature control in houses, apartments, heating zones, offices, showrooms, factories, medical practices, holiday homes • Fast and simple operation of the main day-to-day functions • INFO key for viewing important settings in plain text • Text line in the display provides a step-by-step guide to programming • The technically experienced user can set various individual control modes • Optimal adaptation thanks to operating point and switching differential setting option • Quick start-up via 2 basic programs with individually adjustable comfort and reduced temperature • Individual program with 22 programmable time phases also enables day-time reduced phases e. g. while out working • Comfort and reduced temperature adjustable over range of +10 °C… +30 °C • Frost protection option over range of +6 °C… +10 °C • Party / ECO program with adjustable duration for comfort and reduced temperature without having to modify standard program • Fully automatic summer/winter-time correction • Power reserve approx. 5 hours in event of loss of mains supply • Holiday program with reduced temperature or datecontrolled heating phase, e.g. for holiday homes • 3 or 4-wire connection in base • Plug-in base for wall or flush-mounted socket installation 7d 24 h Holiday ±1h auto Technical data: Switch load: Max. 6 (1) A 250 V~, at least. 1 mA 5 V Contact material: AgSnO Time accuracy: 1 s/day at 20 °C Time based on: Quartz Control accuracy: ≤ ± 0,2 K Temperature display: accurate to 0.1 °C Temperature setting range: +6 °C... +30 °C in 0.2 degree increments Control type options: Pulse width modulation or hysteresis controller Control period: 5…30 mins Control capture range: ± 0.2 K…5 K Protection class: II in accordance with EN 60 730-1 Protection rating: IP 20 in accordance with EN 60529 2 RAMSES 812 top Operating voltage: 230 V, ± 10 % Frequency: 50 Hz Power reserve:Approx. 5 hours, permanent heating operation in the event of power failure Contact: Two-way switch, floating, not for SELV RAMSES 811 top Operating voltage: Battery operation,2 x 1.5 V AA alkaline batteries Battery life: Approx. 1 year, depending on switching frequency Battery replacement time: Max. 10 min. with no loss of time Contact: Two-way switch, floating, suitable for SELV RAMSES 811 top, battery version • Digital clock thermostat as before but with 2 or 3-wire connection, voltage supplied through 2 x 1.5 V AA batteries • Battery monitoring with battery replacement indicator Individual room control Combining the aforementioned clock thermostats with Theben actuators enables convenient, needs-driven individual room control. The actuators are simply screwed onto the individual radiators or into the heating circuit distributor in underfloor heating systems. See page 39 for a detailed description. Type Program Operating voltage Temperature ranger/ m/f Control Contact accuracy Nominal current at 250 V~ Order no. RAMSES 812 top pure white RAL 9010 24 h/7 d 230 V/50 Hz Holiday program +10 °C...+30 °C ≤ ± 0,2 K 1 two-way switch 6 (1) A 812 0 032 +6 °C...+10 °C frost protection RAMSES 811 top pure white RAL 9010 24 h/7 d 2 x 1.5 V AA Holiday program +10 °C...+30 °C ≤ ± 0,2 K 1 two-way switch 6 (1) A 811 9 032 +6 °C...+10 °C frost protection 16 Wall-mounted RAMSES 832 top (mains version) RAMSES 831 top (battery version) 6-30 °C RAMSES 832 top, mains version • Suitable for energy-saving room temperature control in houses, apartments, heating zones, offices, showrooms, factories, medical practices, holiday homes • Ideal device for shift workers as 3 different weekly programs can be set for early and late shifts as well as days off work. One of the 3 programs can be selected as required simply by using the rotary switch • Fast and simple operation of the main day-to-day functions • INFO key for viewing important settings in plain text • Text line in the display provides a step-by-step guide to programming • The technically experienced user can set various individual control modes • Optimal adaptation thanks to operating point and switching differential setting option • Quick start-up via 2 basic programs. Comfort and reduction phase times can be individually amended. 3 comfort and 2 reduced temperatures can be allocated to each phase. • Individual program with 32 programmable time phases also enables day-time reduced phases e. g. while out working • Comfort and reduced temperature adjustable over range of +6 °C… +30 °C • Optimisation function for automatic correction of heating start to enable comfort temperature to be achieved more quickly • Frost protection option over range of +6 °C… +10 °C • Party / ECO program with adjustable duration for comfort and reduced temperature without having to modify standard program • Fully automatic summer/winter-time correction • Power reserve approx. 5 hours in event of loss of mains supply • Holiday program with reduced temperature or datecontrolled heating phase, e. g. for holiday homes • T emperature shock recognition saves heating costs during short ventilation phases. (function can be switched off) • Pump protection function prevents the circulation pumps sticking outside the heating periods through regular short operation. (function can be switched off) • Elapsed-time counters for recording relay switching times e. g. burner running time. • 3 or 4-wire connection in base • Plug-in base for wall or flush-mounted socket installation RAMSES 831 top, battery version • Digital clock thermostat as before but with 2 or 3-wire connection, voltage supplied through 2 x 1.5 V AA batteries • Battery monitoring with battery replacement indicator Type Program Operating voltage Temperature range r/ m/f 7d 24 h Optimisation ±1h auto Technical data: Switch load: Max. 6 (1) A 250 V~, at least. 1 mA 5 V Contact material: AgSnO Time accuracy: 1 s/day at 20 °C Time based on:Quartz Control accuracy: ≤ ± 0,2 K Temperature display: accurate to 0.1 °C Temperature setting range: +6 °C... +30 °C in 0.2 degree increments Control type options: Pulse width modulation or hysteresis controller Control period: 5…30 mins Control capture range: ± 0.2 K…5 K Protection class: II in accordance with EN 60 730-1 Protection rating: IP 20 in accordance with EN 60529 2 RAMSES 832 top: Operating voltage: 230 V, ± 10 % Frequency: 50 Hz Power reserve: approx. 5 hours Contact: Two-way switch, floating, not for SELV Digital controllers Digital clock thermostat with optimisation function RAMSES 831 top: Operating voltage: Battery operation,2 x 1.5 V AA alkaline batteries Battery life: Approx. 1 year, depending on switching frequency Battery replacement time: Max. 10 min. with no loss of time Contact: Two-way switch, floating, suitable for SELV Individual room control Combining the aforementioned clock thermostats with Theben actuators enables convenient, needs-driven individual room control. The actuators are simply screwed onto the individual radiators or into the heating circuit distributor in underfloor heating systems. See page 39 for a detailed description. Control Contact accuracy Nominal current at 250 V~ Order no. RAMSES 832 top pure white RAL 9010 24 h/7 d 230 V/50 Hz Holiday program +10 °C...+30 °C ≤ ± 0,2 K 1 two-way switch 6 (1) A 832 0 032 +6 °C...+10 °C frost protection RAMSES 831 top pure white RAL 9010 24 h/7 d 2 x 1.5 V AA Holiday program +10 °C...+30 °C ≤ ± 0,2 K 1 two-way switch 6 (1) A 831 9 032 +6 °C...+10 °C frost protection 17 Wall-mounted Digital clock thermostat for electric underfloor heatingwith fast heating function and elapsed hours counter RAMSES 818 top 6/16 A • Clock thermostat for underfloor heating, designed for energy saving control of: – electrical underfloor heating – fast reacting underfloor heating systems – Quick heating for 1 h by holding down info key • Operating hours counter for recording power on time • The controllers are equipped with selectable temperature limits 40 °C (tiles) or 30 °C (laminates, wood, cork) • 3 different weekly programs available via rotary switch • Ideal device for shift workers as 3 different weekly programs can be set for early and late shifts as well as days off work. • Quick start up and easy use for day-to-day functions via 2 basic programs • 3 comfort and 2 reduced temperatures can be allocated to the 32 programmable time phases • Info key for viewing important settings • Text line in the display provides a step-by-step guide to programming • Different control types can be individually set • Optimal adaptation thanks to operating point and switching differential setting option • Comfort and reduction phase of +6 °C to +30 °C available allowing a pleasant floor surface temperature to be achieved • Optimisation function for automatic correction of heating start up • Frost protection option over range of +6 °C… +10 °C • Party/ ECO program with adjustable period for comfort or reduced temperature • Power reserve approx. 3 hours in event of loss of mains supply • Easy installation via plug-in base for flush-mounted socket • Specially encapsulated temperature sensor (IP 65) with 4 m connecting cable fir installation in empty pipes Digital controllers RAMSES 818 top 6-30 °C 7d 24 h ±1h Holiday auto Technical data: Operating voltage: 230 V–240 V, ± 10 % Nominal frequency: 50-60 Hz Power reserve: 3 hours Time accuracy: ±1 s/d at 20 °C Contact: Changeover switch, floatingmax. 6 A/250 V~, min.1 mA/5 V Control accuracy: ± 0.2 K Temperature display: accurate to 0.1 °C Temperature measuring range: 0 °C...+50 °C Temperature setting range: +6 °C...+30 °C (+40 °C) in 0.2 degree increments Control period: 5...30 min (PD controller) Control capture range: ±0.2 K…±5 K (PD controller) Switching hysteresis: ±0.2 K…±1.0 K (hysteresis controller) Memory locations: 32 temperature changes, programmable for Mon–Fri, Sat–Sun, every day or individual days Protection class: ll in accordance with EN 60 730-1 subject to designated installation Protection rating: IP 21 in accordance with EN 60 529 RAMSES 818 top 16 A Contact: NO contact, max. 16 A/250 V~ Protection class: ll in accordance with EN 60 730-1 subject to designated installation in a flush-mounted socket Basic program: Program 1: Mon–Fri Comfort 5.30– 9.00 and 21.00–23.00 Sat/Sun Comfort 7.30–10.30 and 21.00–23.00 Program 2: Mon–Fri Sat/Sun Comfort 6.00– 8.00 and 16.00-22.00 Comfort 6.00– 8.00 and 16.00-23.00 Program 3: freely programmable Elektroheizung 2 2 RAMSES 818 top 230 V~ Electric under-floor heating Dimensional diagrams 145 3 4 5 6 32 7 6 2 4000 98.3 1 32.2 Type Program 18 Nominal voltage Temperature Connection Contact range r/ m/f Nominal current at 250 V~ Order no. RAMSES 818 top 6 A 24 h/7 days 230 V/50 Hz Holiday program +6 °C...+30 °C (+40 °C) +6 °C...+10 °C frost protection 3 or 4 way conductors + 2 wire sensor 1 two-way switch 6 (1) A 818 0 035 RAMSES 818 top 16 A 24 h/7 days 230 V/50 Hz Holiday program +6 °C...+30 °C (+40 °C) +6 °C...+10 °C frost protection 3 or 4 way conductors + 2 wire sensor 1 NO contacts 16 (2) A 818 0 036 Wall-mounted 6-30 °C Function: Clock thermostat as RAMSES 812 top except for additional modem interface for remote adjustment of set temperatures via phone or SMS. Switchable for 2 or 3-point control or 2-stage control with sequence-controlled contact. RAMSES 816 top • Clock thermostat for universal application • Simple retrofitting through 2-wire Open Therm connection in living space, no battery operation • Option for remote control of set temperature via telephone or SMS with additional voice modem or GSM modem • Switchable for on/off or 3-point control with 8 A/250 V~ switching outputs • Second switching step controllable by adjustable switching differential temperature • Suitable for 2-phase burners, blowers, convectors, additional heaters for under-floor heating etc. • An additional feed sensor is required for mixer control • 2-wire BUS connection from room thermostat to control unit with power pack and 2 output relays • Both devices with plug-in base and large terminal area • Simple connection through short-circuit proof and non-reversible 2-wire BUS (protection class III) RAMSES 816 top OT 7d 24 h ±1h Holiday auto Technical data: Operating voltage: 230 V~, +10 %/-15 % Nominal frequency: 50-60 Hz Power reserve: approx. 4 hrs. after 3 days charging time Switch load: max. 8 (1) A/250 V Contact material: AgNi Contact: 1 two way switch and 1 NO contact, floating, not for SELV Time based on: Quartz Control accuracy: ± 0.2 K Temperature display: accurate to 0.1 °C Temperature measuring range: 0 °C... +50 °C Temperature setting range: +10 °C... +30 °C in 0.2 degree increments +6 °C... +10 °C frost protection Memory locations: 32 freely programmable memory locations with free weekday block formation Protection class: ll in accordance with EN 60730-1 subject to designated installation Protection rating: IP 20 in accordance with EN 60529 Digital controllers Open Therm digital clock thermostat for 2 or 3-point control OT-Box RAMSES 816 top Accessories: MODEM RAMSES 816 top 2-wire OT BUS RS 232 3 point control Feed temperature sensor for mixer control urgently required Heating stage II ϑ 2 M OT box 2 230 V~ 2/3 Connection diagrams see page 28. 2 Dimensional diagrams 145 2 3 4 5 6 7 98.3 1 32.2 GSM modem Type Program Operating voltage Temperature range r/ m/ f Temperature differential for sequence-controlled Connection contact RAMSES 816 top 24 h/7 days 230 V/50 Hz +6 °C bis +30 °C 0.5 to 2.5 K 2 wires Holiday program Contact Control unit Nominal current at 250 V~ Order no. 1 NO contacts 1 two-way switch 8 (1) A 816 9 032 Feed temperature sensor for mixer control with RAM 816 / 817 top required GSM modem incl. antenna, power unit and connecting cables 907 0 371 907 0 396 19 Wall-mounted Open Therm digital clock thermostat with weather compensation remote sensor 6-30 °C RAMSES 817 top As RAMSES 816 top, with separate temperature weather compensation sensor for wall mounting (included in set) • Also suitable for temperature control in dusty or humid rooms • External temperature sensor in wall-mounted housing with protection rating to IP 65 and protection class III, cable length 4 m • RAMSES 382 FA sensor can be connected to OT-Box as an option • Maximum sensor cable length 50 m, Ø > 0.75 mm2 • Both devices with plug-in base and large terminal area • Simple connection through short-circuit proof and nonreversible 2-wire BUS (protection class III) • An additional feed sensor is required for mixer control Digital controllers RAMSES 817 top OT OT-Box RAMSES 817 top 7d 24 h ±1h Holiday auto Technical data: Operating voltage: 230 V~, +10 %/-15 % Nominal frequency: 50-60 Hz Power reserve: approx. 4 hrs. after 3 days charging time Switch load: max. 8 (1) A, 250 V~ Contact material: AgNi Contact: 1 NO contact and 1 two way switch, floating, not for SELV Time based on: Quartz Control accuracy: ≤ ± 0,2 K Temperature display: accurate to 0.1 °C Temperature measuring range: 0 °C... +50 °C Temperature setting range: +10 °C... +30 °C in 0.2 degree increments +6 °C... +10 °C frost protection Memory locations: 32 freely programmable memory locations with free weekday block formation Protection class: ll in accordance with EN 60 730-1 subject to designated installation Protection rating: IP 20 in accordance with EN 60529 Temperature sensor: IP 65 in accordance with EN 60529 External temperature sensor IP 65 Accessories: Sensor connection on room thermostat also possible 2 MODEM 2 RAMSES 817 top 2-wire OT BUS External temperature sensor IP 65 Feed temperature sensor for mixer control urgently required RS 232 3 point control Heating stage II ϑ 2 OT box 2 230 V~ M Connection diagrams see page 28. 2/3 2 Dimension diagrams 145 3 4 5 6 7 c 67 2 98.3 1 32.2 c 74 5 GSM modem 23.3 Type Program Operating voltage Temperature range r/ m/ f Temperature differential for sequence-controlled Connection contact RAMSES 817 top 24 h/7 days 230 V/50 Hz +6 °C bis +30 °C 0.5 to 2.5 K 2 wires Holiday program Contact Control unit Nominal current at 250 V~ Order no. 1 NO contacts 1 two-way switch 8 (1) A 817 9 032 Feed temperature sensor for mixer control with RAM 816 / 817 top required GSM modem incl. antenna, power unit and connecting cables 20 907 0 371 907 0 396 Wall-mounted 5–39 °C Function: Theben offers an innovative system for room temperature control in combination with under-floor and radiator heating. Cost-efficient and convenient retrofitting for all systems through radio-control This creates new retrofitting opportunities, not only in new-build but predominantly in occupied flats, apartments and functional buildings. Each system comprises a clock thermostat per room with integrated radio transmitter and a receiver. For control over several rooms, several sets can be operated in parallel • RAMSES 813 top HF, the new radio system enables optimal energy saving while ensuring a comfortable environment • The sets can be upgraded with further modules for operation over several heating zones without mutual interference • Operation is especially simple thanks to step-by-step user guidance through text lines in the display • A rotary switch can be set to one of 3 different programs (2 pre-programmed basic and one customised program with a max. of 22 temperature phases • Further comfort functions include party and ECO programs, date-controlled holiday program and automatic summer/wintertime changeover. • The highly-modern radio system is digitally-coded and protected against interference from other radio systems • The control unit reliably receives the radio signals of the battery-powered room transmitter in the building through walls and ceilings • High interference immunity through repeated transmission of coded ON/OFF signals for each channel, ensuring zero failure even in large buildings with individual room controls • Level display with 5 LEDs for checking reception quality and detecting interference fields at the installation location • Extremely reliable thanks to battery monitoring and battery replacement indicator • Simple battery replacement without loss of time of program • Emergency receiver function, in the event of transmitter failing or radio receiver being defective over a prolonged period RAMSES 813 top HF (radio) REC 11 receiver (set A) 7d 24 h ±1h Holiday auto Technical data: Control accuracy: ± 0.2 K Control period: 5...30 min Transmission frequency: 868 MHz Transmission power: < 10 mW Transmission frequency and transmission power do not need to be registered in Germany. Power supply: 2 x 1.5 V AA alkaline batteries Battery life: approx. 2 years, depending on switching frequency Range: Approx. 25-30 m in buildings, depending on type REC 11/21 receiver Operating voltage: 230 V, ±10 %, 50/60 Hz Switching capacity: 16 (2) A/250 V~ (Set A) floating, not for SELV 16 (2) A/230 V~ (Set S) not floating Coding: 65536 Codes Field strength display: 5 LEDs Relay status display: 1 LED Protection class: ll in accordance with EN 60730-1 subject to designated installation Protection rating: IP 20 in accordance with EN 60529 Digital controllers Digital clock thermostat with radio control RAMSES 813 top HF, Set A, 1 zone controller • Consisting of 1 RAMSES 813 top2 HF clock thermostat and an REC 11 receiver with a NO contact 16 (2) A/ 250 V~, for wall-mounting REC 21 receiver grounding intermediate connector (Set S) RAMSES 813 top HF, Set S, 1 zone controller • Consisting of a RAM 813 top HF clock thermostat and a REC 21 receiver as grounding intermediate connector (16 (2) A) e. g. for heated towel rail or fan heater Dimensional diagrams Individual room control 145 2 3 4 5 6 Combining the aforementioned clock thermostats with Theben actuators enables convenient, needs-driven individual room control. The actuators are simply screwed onto the individual radiators or into the heating circuit distributor in underfloor heating systems. See page 39 for a detailed description. 7 98.3 1 32.2 Clock thermostat Receiver Type Programs Temperature Switching differential Connection range r/ m/f adjustable Nominal Contact Nominal current voltage Order no. RAMSES 813 top HF Set A 24 h/7 days Holiday program +6 °C - 30 °C ± 0.2 K wireless Frost protection 230 V 50/60 Hz 1 NO contacts 16(2) A/250 V~ 813 9 403 RAMSES 813 top HF Set S 24 h/7 days Holiday program +6 °C bis 30 °C ± 0.2 K wireless Frost protection 230 V 50/60 Hz 1 NO contacts 16(2) A/230 V~ 813 9 405 21 Wall-mounted Digital clock thermostat with radio control 6-30 °C Function: Theben offers an innovative system for room temperature control in combination with under-floor and radiator heating. Cost-efficient and convenient retrofitting for all systems through radio-controlled communication. This creates completely new opportunities, not only in new-build properties but predominantly in occupied flats, apartments and functional buildings. Each system comprises a clock thermostat per room with integrated radio transmitter and a receiver. For control over several rooms, several sets can be operated in parallel Digital controllers RAMSES 813 top HF (radio) REC 1 (1 channel receiver, 868 MHz) • RAMSES 813 top HF, the new radio system enables optimal energy saving while ensuring a comfortable environment • The sets for 1/2 heating zones can be upgraded with further modules for operation over several heating zones without mutual interference • Operation is especially simple thanks to step-by-step user guidance via on screen texts • A rotary switch can be set at any time to one of 3 programs (2 pre-programmed basic and one individualised program with a max. of 22 temperature phases) • Further comfort functions include party and ECO programs, date-controlled holiday program and automatic summer/wintertime changeover • The radio system is digitally-coded and protected against interference from other radio systems • The central control unit reliably receives the radio signals of the battery-powered room transmitter in the building through walls and ceilings • High interference immunity through repeated transmission of coded ON and OFF signals for each channel, ensuring zero failure even in large buildings with individual room control • Level display with 5 LEDs for checking reception quality and detecting interference fields at the installation location • Projection antenna for optimising reception quality • High reliability through battery monitoring • Simple battery replacement without loss of time or program • Control device with floating two way switch 6 (1) A/250 V~ • Emergency receiver function, in the event of transmitter failing or radio receiver being defective over a prolonged period 7d 24 h ±1h Holiday auto Technical data: Control accuracy: < ± 0.2 K Control period: 5...30 min Transmission frequency: 868 MHz Transmission power: < 10 mW Power supply: 2 x 1.5 V AA alkaline batteries Battery life: approx. 2 years, depending on switching frequency Range: Approx. 20–30 m in buildings depending on type If the standard projection antenna is insufficient due to unfavourable reception, a rod antenna can be used to improve reception quality REC receiver Operating voltage: 230 V~, +10 %/–15 %, 50–60 Hz Switching capacity: 6 (1) A/250 V~, floating, not for SELV Antenna system: Projection antenna Field strength display: 5 LEDs Relay status display: 1 LED per channel Protection class: ll in accordance with EN 60730-1 subject to designated installation Protection rating: IP 20 in accordance with EN 60529 RAMSES 813 top HF, Set 1, 1 zone controller • Consisting of RAM 813 top HF clock thermostat and a receiver with a two way switch 6 (1) A/250 V~ and wall installation set RAMSES 813 top HF, Set 2, 2 zone controller • Consisting of two RAM 813 top HF clock thermostat and a 2-channel receiver with 2 two way switches 6 (1) A/ 250 V~ and wall installation set REC 2 (2 channel receiver, 868 MHz) RAMSES 813 top HF, Set 4, 4 zone controller • Consisting of four RAM 813 top HF clock thermostats and two 2 channel receivers with 4 two way switches Dimensional diagrams Individual room control 145 5 6 7 125* 22 45 4 80 3 65,5 60 90 128* 2 98.3 1 32.2 55* Combining the aforementioned clock thermostats with Theben actuators enables convenient, needs-driven individual room control. The actuators are simply screwed onto the individual radiators or into the heating circuit distributor in underfloor heating systems. See page 39 for a detailed description. Wall-mounted Digital clock thermostat with radio control 6-30 °C RAM 813 top HF RAM 813 top HF REC C1 M 1 2 3 4 5 6 RAM 813 top HF C1 C1 REC 7d 24 h ±1h Holiday auto 7 8 C1 1 2 3 L N C2 C2 4 5 6 M 7 8 L N L N L N RAMSES 813 top HF, Set 1, REC receiver REC receiver controls thermal actuator for hot water heating or radiator valve and/or recirculation pump or electric heating RAMSES 813 top HF, Set 2, REC receiver REC receiver controls e. g. two heating circuits with actuator for hot water heating or radiator valve and/or recirculation pump or electric heating Radio pilot room controller e.g. for 2 flats (2 zone control) ➊ RAM 813 top HF clock thermostat per flat with transmitter in the most-used room (pilot room), no connection wires required. ➋ Receiver with 2 channels controls the heat supply to the two flats via the respective recirculation pump. Digital controllers ➊ Flat 1 ➊ Flat 2 ➋ e.g. bathroom Individual radio room control for 2 and more rooms with under-floor heating ➊ RAM 813 top HF clock thermostat with transmitter in each living room or office. ➋ Receiver in heating circuit distributor switches the Theben actuator drives that control the heat supply to the individual heating circuits. ➌ Actuators can be attached to available valves in the heating circuit distributor. e. g. living room ➊ ➊ ➋ ➌ Type Clock thermostat Receiver Programs Temperature Switching differential Connection range r/ m/f Nominal Contact voltage Nominal current at 250 V~ Order no. RAMSES 813 top HF Set 1 24 h/7 days Holiday program +6 °C - 30 °C ± 0.2 K wireless Frost protection 230 V 50/60 Hz 1 two-way switch 6 (1) A 813 9 401 RAMSES 813 top HF Set 2 24 h/7 days Holiday program +6 °C - 30 °C ± 0.2 K wireless Frost protection 230 V 50/60 Hz 2 two-way switch 6 (1) A 813 9 402 RAMSES 813 top HF Set 4 24 h/7 days Holiday program +6 °C - 30 °C ± 0.2 K wireless Frost protection 230 V 50/60 Hz 4 two-way switch 6 (1) A 813 9 404 UHF rod antenna for 868 MHz with wall holder and 2 m screened connection cable (required only for unfavourable reception quality). Terminal box cover plate for the receiver is included in the scope of supply. 907 0 334 23 Wall-mounted Open Therm heating controller for on/off or 3-point control, weather-dependent, service water and circulation control Digital controllers RAMSES 855 top2 OT New RAMSES 855 top Installation in living areas or in boiler rooms OT-Box RAMSES 855 top Installation in boiler room 6-30 °C RAMSES 855 top / RAMSES 855 top2 OTUniversal digital heating controller with 4-channel digital control, complete room operation and monitoring. Additional modem interface (RS 232) for remote temperature setting by phone or SMS. Extremely simple operation through text guidance display and pre-configured programs for families and working people. Fast installation through 2-wire control device to controller connection in the boiler room. • Boiler/feed temperature (control circuit 1) controlled by switching the burner • Feed temperature (control circuit 2) controlled via pump or mechanically-adjustable mixer • 3-point controller with feed sensor • Mixer control with feed temperature limit • Hot water controlled by switching load pump • Highly economical control of hot water circulation pump, as time and temperature dependent • Simple to operate via selector switch for 8 different connection /function types. • Automatic sensor recognition for weather or room dependent control; can be switched manually at any time • Simple selection of 3 switching programs. An individual weekly program, e.g. for shift workers, 2 pre-configured programs for families and working people (855 top2). • Choice of 3 permanent programs: Comfort, reduced, frost-protection • Info button for viewing key data such as date, time, program and set point/actual temperature and ambient temperature. Displays the switching status of the outputs. • RS 232 interface for: – GSM modem set point temperature setting via SMS • Additional switching program for service water utilisation times • Adjustable service water storage temperature,additional legionella protection can be configured through shortterm interval based feed heating • Party/Eco program with adjustable period for comfort or reduced temperature • Date-controlled holiday program • Automatic summer/winter time switchover • Pump block protection OT Center • extends the RAMSES 855 top with– an additional mixer circuit– chimney sweep function– a relay output for error messages OT Center Installation in boiler room 7d 24 h ±1h Holiday 7d auto Technical data: Operating voltage: 230 V~, +10 %/–15 % Nominal frequency: 50-60 Hz Power reserve: Approx. 3 hours after 3 days charging time Memory locations: 32 Switch load: 8 (1) A, 250 V~ Contact material: AgNi Contacts: floating, not for SELV Switching hysteresis: 2-20 K Mixer runtime: 2-10 min Heating curves: infinite, individual adjustment for radiator and under-floor heating through low end and final point adjustment Adjustment ranges for room-dependent control: – Comfort temperature: +15 °C... +30 °C – Reduced temperature: +10 °C... +29,8 °C – Frost protection: +6 °C... +15 °C Protection class: ll in accordance with EN 60 730-1 subject to designated installation Protection rating: IP 20 in accordance with EN 60529 RAMSES 855 topinputs: • External sensor (contained in set) • Heating circuit feed sensor(contained in set) • Feed or plunge sensor for service water • Feed sensor for circulation Outputs: • 4 NO contacts OT Centerinputs: • Feed sensor (included in the scope of supply) • “Chimney sweep” switch Outputs: • 3 NO contacts 5 (1) A, 250 V~ • 1 two way switch 5 (1) A, 250 V~ Accessories: External temperature Feed temperature sensor sensor for mixer control urgently required Dimension diagram 145 2 3 4 5 6 7 98.3 1 32.2 GSM modem Type Program Operating voltage Temperature range r/m/f Adjustable feed temperature limit Connection Contact Control unit Nominal current at 250 V Order no. RAMSES 855 top2 OT 24 h/7 days incl. OT box Holiday prog. 230 V/50 Hz +6 °C bis +30 °C +40 °C - +90 °C 2 wires 8 (1) A 855 9 132 RAMSES 855 top incl. OT box 24 h/7 days Holiday prog. 230 V/50 Hz +6 °C bis +30 °C OT Center 230 V/50 Hz +6 °C bis +30 °C +30 °C to +75 °C 4 NO contacts (Available from Sept. 2009) +40 °C - +90 °C 2 wires 4 NO contacts 3 NO contacts, 1 two way switch 8 (1) A 855 9 032 5 (1) A 907 0 427 855 9 901 907 0 371 907 0 379 907 0 396 Set RAMSES 855 top + OT Center Feed temperature sensor additionally required for applications with 2 feed sensors Plunge sensor (Ø 6 mm) additionally required for applications with service water control or boiler plunge sensor GSM modem incl. antenna, power unit and connecting cables 24 Wall-mounted Open Therm heating controller for on/off or 3-point control, weather-dependent, service water and circulation control 6-30 °C 7d 24 h ±1h Holiday auto The RAM 855 provides the following types of control: ϑ 1.) Weather-dependent heating control with outside temperature sensor. The control device can be installed in the living room or heating room. The OT Box with power unit and relay is installed in the heating room. 2 2 2.) Room-temperature driven control without outside temperature sensor. A room temperature sensor is built into the operating device so that sunlight, fireplaces and other heat sources can be taken into account. An additional voice modem in the room-dependent controller makes it possible to set the remote temperature over thetelephone. OT-Box Connection diagram 1 Heating control via circulation pump with boiler control OT-Box 1 7 2 3 4 5 6 M OT-Box RAMSES 855 12 13 14 15 16 17 18 19 10 11 Feed temperature control via burner control Feed temperature control via burner control with service water and circulation control (connection diagram 1) 8 9 AF BWT BWRF L N AF BWF KF/VLF BWRF Heating control via a motor-driven mixer = = = = LP ZP HP KF/VLF Outside temperature sensor Household water temperature sensor Boiler/Forward flow temperature sensor Household water return flow sensor LP = Loading pump household water HP = Heating pump ZP = Circulation pump RAMSES 855 top / RAMSES 855 top2 OT weather or room-dependent heating controller, mixer control and service water temperature control OT-Box OT-Box Connection diagram 2 M M M Mixer OTBUS 1 Feed temperature control via mixer control Feed temperature control via mixer control with service water control (connection diagram 2) 7 2 3 4 5 6 M OT-Box RAMSES 855 ϑ 8 9 12 13 14 15 16 17 18 19 10 11 ϑ ϑ BWT OT-Box Feed temperature control via mixer and burner control open ϑ AF M closed L N LP HP VLF AF = Outside temperature sensor BWF = Household water temperature sensor VLF = Forward flow temperature sensor LP = Loading pump household water HP = Heating pump RAMSES 855 top / RAMSES 855 top2 OT weather or room-dependent heating controller, mixer control and service water temperature control Connection diagram 3 230 V~ L1 N 1 2 3 4 5 6 7 12 13 14 15 16 potential-free contact “Error“ 8 9 18 19 OT Center 11 10 ϑ 17 OT box 4,7 k “Chimney sweep” connection NTC switch see above off on Heating circuit pump Mixer RAMSES 855 top / RAMSES 855 top2 OT + OT Center Mixer circuit upgrade via OT center 25 Digital controllers OTBUS OT-Box Distributor installation Zone control (6 TE) 7d 24 h ±1h Holiday auto Function Clock thermostat for distributor installation for remote temperature control. Protected against unauthorised adjustment, therefore suitable for offices, practices, retail premises, schools and meeting rooms. RAMSES 366/1 top, 1 zone • Clock thermostat with daily/weekly/holiday programs for setting comfort/reduced temperature phases • Daytime temperature range +6 °C... +30 °C and night-time temperature range of +6 °C... +26 °C • Daily/weekly program can be set to the minute • 42 memory locations, date-controlled holiday program • Operator guidance through integrated text line on the LCD screen (see page 25) • Programming displayed graphically by a bar arrangement in the LCD display • Automatic summer/winter-time correction, can be disabled or programmed as required (CET, GB, USA changeover rule also available) • Guided copying of switching times to other weekdays (free block formation) • 10 year power reserve • Manual switching pre-selection and operating mode selector switch for: Automatic mode, comfort mode, reduction mode, frost protection mode • Connection for telephone remote control for switching to comfort mode or frost protection mode over the telephone • LED display of active operating status as well as relay status • Remote temperature sensor required, see accessories • Two-way switch, floating 10 (2) A/250 V~, not for SELV • Terminal cover for wall installation, sealable no. 907 0 053 • Control panel installation with assembly kit no. 907 0 001 • Program storage via EEPROM • PIN code Digital controllers RAMSES 366/1 top RAMSES 366/2 top RAMSES 366/1 top ϑ L N M 1 2 3 4 5 6 7 8 9 ϑ * L N ** RAMSES 366/2 top ϑ L N 1 2 3 ϑ 4 5 6 M 7 8 9 10 11 12 13 14 ϑ ϑ L N * * *Control of circulation pump, electronic actuator, thermal mixer valve or oil/gas burner ** RAMSES 366/2 top, 2 zones • Clock thermostat as above but for 2 zones with different temperature phases • 42 memory locations • 2 remote temperature sensors required, see accessories • 2 x two-way switches, floating 10 (2) A/250 V~, not for SELV Dimension diagrams for RAMSES 366 top + remote sensor Terminal box cover plate % Common technical data: Operating voltage: 230 V~, +10 % /–15 % Frequency: 50–60 Hz Power consumption: max. 3 VA Time based on: Quartz Time accuracy: ≤ ±1 s/day at 20 °C Shortest switching time: 1 min Power reserve: 10 years using lithium battery (20 °C) Connection voltage at sensor: SELV Contact: opening width less than 3 mm (µ), floating, not for SELV Contact material: AgCdO Permissible ambient temperature: -10 °C... +50 °C Housing and insulation material: High-temperature resistant, self-extinguishing thermoplastic Max. connection cross-section: 4 mm2 Protection class: II in accordance with EN 60 730-1 with designated installation protection class III for remote sensors 1 and 2 Protection rating: IP 20 in accordance with EN 60 529 Accessories: Remote sensor 1 Remote sensor 2 with temperature adjustment ± 3 K **Connection for separate telephone remote switch TF Individual room control Combining the aforementioned clock thermostats with Theben actuators enables convenient, needs-driven individual room control. The actuators are simply screwed onto the individual radiators or into the heating circuit distributor in underfloor heating systems. See page 39 for a detailed description. *with terminal box cover plate Model Program Power reserve approx. Temperature range r/ m Switching Special function Contact differential Nominal current Order no. at 250 V~ RAMSES 366/1 top 24 h/7 days 10 years Holiday program +6 °C bis +30 °C ≤ 0.5 K +6 °C to +26 °C Connection for 1 two-way switch Telephone remote switch 10 A 366 0 002 RAMSES 366/2 top 24 h/7 days 10 years Holiday program +6 °C bis +30 °C ≤ 0.5 K +6 °C to +26 °C Connection for 2 two-way switch Telephone remote switch 10 A 366 0 052 Remote sensor 1, suitable for RAMSES 366/1 top and RAMSES 366/2 top Remote sensor 2, with temperature adjustment suitable for RAMSES 366/1 top and RAMSES 366/2 top 26 907 0 191 907 0 192 Flush-mounted/wall mounting Digital clock thermostat 6–30 °C 7d 24 h Holiday ±1h auto RAMSES 823 top, white (mains version) RAMSES 821 top, white (battery version) Technical data: Switch load: Max. 6 (1) A 250 V~, at least. 1 mA 5 V.... Contact material: AgSnO Time accuracy: 1 s/day at 20 °C Time based on: Quartz Control accuracy: ≤ ± 0.2 °C Temperature display: accurate to 0.1 °C Temperature setting range: +6 °C... +30 °C in 0.2 degree increments Control type options: Pulse width modulation or hysteresis controller Control period: 5…30 mins Control capture range: ± 0.2 K…5 K Protection class: II in accordance with EN 60 730-1 Protection rating: IP 20 in accordance with EN 60529 Housing colour: pure white RAL 9010 2 RAMSES 822 top Operating voltage: 230 V~,+10 %/–15 % Frequency: 50 Hz Power reserve: Approx. 5 hours, continuous heating operation in the event of power failure Contact: Two-way switch, floating, not for SELV Digital controllers RAMSES 822 top, white (mains version) RAMSES 820 top, white (battery version) RAMSES 822 top, mains version • Digital clock thermostat in a low profile, attractive design that can easily be integrated into any living room • Suitable for energy-saving room temperature control in houses, apartments, heating zones, offices, showrooms, factories, medical practices, holiday homes • Fast and simple operation of the main day-to-day functions • INFO key for viewing important settings • Text line in the display provides a step-by-step guide to programming • The technically experienced user can set various individual control modes • Optimal adaptation thanks to operating point and switching differential setting option • Quick start-up via 2 basic programs with individually adjustable comfort and reduced temperature • Individual program with 22 programmable time phases also enables day-time reduced phases e.g. while out at work • Comfort and reduced temperature adjustable over range of +10 °Cto +30 °C • Frost protection option over range of +6 °C… +10 °C • Party / ECO program with adjustable duration for comfort and reduced temperature without having to modify standard program • Fully automatic summer/winter-time correction • Text guidance option available in 5 languages • Holiday program with reduced temperature or datecontrolled heating phase, e.g. for holiday homes • Plug-in base for flush-mounted socket with 3 or 4 wire connection RAMSES 820 top Operating voltage: Battery operation,2 x 1.5 V AAA alkaline batteries Battery life: Approx. 1 year, depending on switching frequency Battery replacement time: Max. 10 min. with no loss of time Contact: Two-way switch, floating, suitable for SELV RAMSES 820 top, battery version as RAM 822 top however • Digital clock thermostat with 2 or 3-wire connection, voltage supplied via 2 x 1.5 V AAA batteries included • Battery monitoring with battery replacement indicator RAMSES 823 top, mains version as RAM 822 top however • Housing for wall mounting Dimensional diagrams 118 Connection diagrams see page 28. Installation Individual room control 21 80 17 RAMSES 821 top, battery version as RAM 820 top however • Housing for wall mounting Flush box mounted 60 Combining the aforementioned clock thermostats with Theben actuators enables convenient, needs-driven individual room control. The actuators are simply screwed onto the individual radiators or into the heating circuit distributor in underfloor heating systems. See page 39 for a detailed description. Type Installation Program Nominal voltage Temperature Contact range r/ m/f RAMSES 822 top RAMSES 823 top flush-mounted wall-mounted 24 h/7 d Holiday program 230/240 V 50/60 Hz +10 °C...+30 °C 1 two-way switch 6 (1) A +6 °C...+10 °C frost protection 822 0 031 823 0 031 RAMSES 820 top RAMSES 821 top flush-mounted wall-mounted 24 h/7 d 2 x 1.5 V AAA Holiday program +10 °C...+30 °C 1 two-way switch 6 (1) A +6 °C...+10 °C frost protection 820 9 011 821 9 011 Nominal current at 250 V~ Order no. 27 Wall-mounted Connection diagrams OT BUS: 2-wire BUS between control device and switching unit. The BUS wire carries SELV. Connection examples for RAMSES 822 top OTBUS 6 2 3 4 OT-Box RAM 816 top M 7 – M 2 3 4 OT-Box RAM 816 top + ϑ M 7 II I ϑ 13 Control of a 13 burner 15 16 17 18 19 closed 15 16 17 18 19 open M Forward flow temperature sensor Digital controllers 5 4 3 62 1 OTBUS Level II L N Level I 5 4 3 2 1 L N RAMSES 816 top controls mechanical mixing valve Control via the recirculation pump or storage/hot air heating OTBUS 6 2 3 4 OT-Box RAM 816 top M 7 II I Connection examples for RAMSES 820 top ϑ 13 15 16 17 18 19 Level II 3 2 1 Level I L N RAMSES 816 top controls 2 heating stages (2-stage blower, under-floor heating, radiators etc.) Control of a burner OTBUS OTBUS 6 2 3 4 OT-Box RAM 817 top M 7 – M 2 3 4 OT-Box RAM 817 top + ϑ ϑ 12 13 Remote temperature sensor Forward flow temperature sensor M 7 – M ϑ closed open M RAMSES 817 top controls mechanical mixing valve + Control via the recirculation pump or storage/hot air heating 12 13 15 16 17 18 19 15 16 17 18 19 L N 28 3 2 61 closed Forward flow temperature sensor L N open M Wall-mounted Connection diagrams 5 2 1 N N RF > N L RAMSES 701 TA L RAMSES 706 3 2 1 N N N TR TR RF ϑ RAMSES 708 L N ϑ ϑ> RAM 741 L N L N L N TA 1 2 3 L ϑ M L 2 N 16 A <ϑ RF RF N L N N ϑ ϑ AB RAMSES 709 RAM 746 N RF RAMSES 707 52 3 2 1 N N < 6 5 2 N N ϑ> RF L N ϑ> N TA L N L N RF RAMSES 704 RF RAMSES 705 L N L 6 5 2 N N ϑ> N L RF RAMSES 702/703 6 5 2 N N L N 6 5 2 N N > > L TA Digital controllers 2 1 N N RAMSES 741 RAM 748 L N L N L N TA L N TA L <ϑ 1 2 3 L M 1 2 3 N <ϑ L M 1 2 3 N AB RF TR N L N L ϑ TR RF ϑ ϑ N L M N TR TR ϑ AB AB AB RAMSES 746 RAMSES 748 L N L N L N L N 2 1 2 3 1 2 3L 16 A ϑ L N N N L M N 1 4 2 1 1 TR AB RAMSES 714/714 A L N ϑ M L N 1 = Electric standby-by heating 2 = Ventilator/air-conditioning ϑ ϑ AB SOTHIS 715 Heating/actuator/magnetic valve/burner/circulation pump/night storage blowers Electric standby-by heating 29 Wall-mounted CO2 sensor for ventilation control and monitoring of air quality in the room AMUN 716 Suitable for conference and meeting rooms, offices, schools/nurseries, passive and low-energy housing without controlled ventilation. AMUN 716 R New AMUN 716 USB AMUN 716 R switch and analog outputs • CO2 sensor for automatic ventilation control • 2 CO2 controlled switch outputs for 2 stage control • 3 x 0–10 V outputs for CO2, temperature and relative humidity • Switch output with manual and automatic operation as well as display of switching status • Warning display for CO2 concentration (lights) • Simple wall or flush mounted alternatives • Optionally available power unit for flush-mounted installation • Simple upgrade of uncontrolled ventilation systems possible AMUN 716 USB • Simple start-up and use on PC via USB interface • Graphical representation of CO2 levels on PC • Representation of course of last 80 minutes using diagrams • Additional display of current CO2 level on sensor via 5 LEDs • Acoustic and visual warning signals on reaching the limit value • Adjustable acoustic alarm threshold • Log file of CO2 levels can be saved • Saves automatically during extended recordings • Maintenance-free sensor through sealed measuring unit • Software for Windows 98 SE/ME/2000/XP Other CO2 Carbon dioxide is only life-threatening at a concentration above 20% but well-being, concentration and performance are all unconsciously affected at levels above 0.08%. DIN 1946 recommends a maximum value of 0.1 %. This value is often exceeded given modern building standards and the high level of air tightness. Human beings become tired and lose concentration. The CO2 sensor for monitoring indoor air quality uses LEDs to display the CO2 level in the room. CO 24 h 2 Technical data: AMUN 716 R Operating voltage: 14–48 V DC or 16–36 VAC 50–60 Hz Measuring range for 0–10 V outputs: 0–2000 ppm CO 5 °C–40 °C 20–100 % rF CO2 switched thresholds: NO contact 1:700 ppm± 200 ppm NO contact 2:1300 ppm± 200 ppm Setting via ratcheted pentiometer in 100 ppm stages Hysteresis: ± 75 ppm in relation to set value Protection class: II in accordance with EN 60730-1 Protection rating: IP 20 in accordance with EN 60529 2 AMUN 716 USB Operating voltage: 5 V DC via USB bus voltage Measuring range: 0–5000 ppm CO Protection class: III in accordance with EN 60730-1 Protection rating: IP 20 in accordance with EN 60529 2 200 000 Für den Menschen letal (tödlich) 100 000 Verlöschen einer Kerze 40 000…50 000 Ausatem-Konzentration des Menschen 5 000 Maximale ArbeitsplatzKonzentration (MAK-Wert) 4 000 Schlecht gelüftetes Zimmer 1 000 Gefühl von schlechter Luft 330…350 Außenluft CO levels 2 95 Type description Measuring range Display AMUN 716 USB AMUN 716 R Power unit 30 60 97 AMUN 716 R dimension diagrams 97 AMUN 716 USB dimension diagrams 30 60 95 Data interface Order no. 0-5000 ppm 5 LEDs USB716 9 101 CO2sensor incl.software CO2 sensor with 2 relay outputs 0-2000 ppm 6 LEDs 3 x 0–10 V716 0 101 24 V/12 W flush-mounted power unit 907 0 494 Wall-mounted Hygrostat, 74 x 74 mm 5-30 °C SOTHIS 715 • SOTHIS 715 humidity stat in attractively designed installation housing • Setting range 35...100 % rF • Floating two-way switch: humidifier 2 A/250 V~; dehumidifier 5 A/250 V~ • Designed for the control of air humidity or ventilation and dehumidifier systems, not for SELV • Measurement of air humidity via molecular chain alterations in polymer artificial fibres • Use SELV where there is risk of dripping water or build up of condensation in the housing • White housing, 74 x 74 (mm) SOTHIS 715 Technical data: Operating voltage: 230 V, +10 %/–15 %, 50–60 Hz Two-way switch: Humidifier 2A/250 V~ Dehumidifier 5 A/250 V~ Protection class: II in accordance with EN 60730-1 subject to designated installation Protection rating: IP 30 in accordance with EN 60529 Housing colour: pure white (RAL 9010) Connection diagrams see page 29. Wall-mounted Other Hygrostat, 74 x 74 mm � 67 Dimensional diagrams � 74 � 79 5 7.5 23.3 28 Type description Setting range Contact Order no. SOTHIS 715 Hygrostat Adapter plate for flush mounted socket 79 x 79 mm 715 0 002 907 0 212 35…100 % rF Two-way switch, 2/5 A, 250 V~ 31 Din rail program Digital time switches 1–2 channels (2 modules) 7d 24 h ±1h PC auto Digital time switches with text-oriented user guidance in the display, OBELISK interface and DuoFix plug-in terminals. V TR 610 top2 Functions: • Daily and weekly program • Operating by means of 4 keys arranged in one row • Integrated running-time meter for max. 500.000 hours with reset option and service function for monitoring of maintenance intervals and „Service“ display, separately for each channel • Plug-in spring terminals, each one accepting 2 conductors, wires or strands • Display illumination (can be switched off) • Interface for OBELISK top2 memory card for PC programming, 2nd switching program to be plugged in, copying of programs and safe storage of the program • Date-controlled holiday program • Automatic summer/winter time changeover can be alternatively switched off or randomly programmed (MEZ, GB, USA changeover norm selectable) • Preset ex factory of date, time and summer/winter changeover • Extended temperature range –30 °C ... +55 °C • High accuracy: ± 0,5 s/day • 10 years power reserve by lithium cell • Zero cross switching for relay-saving switching and high lamp loads • Switching preselection • Permanent switching ON/OFF • PIN encoding TR 610 top2 Termina ® • 1 channel with 56 memory locations, EEPROM V T R 612 top2 Termina ® • 2 channels with 56 memory locations, EEPROM Dimension drawings DIN 43 880 Terminal cover 69.2 63.7 45.1 90.1 52.9 * 2 Design • Standarrdized housing 45 x 35 x 60 mm according to DIN 43 880 • Quick fastening for 35 mm profile rail (DIN EN 50 022) • Contact protection according to accident prevention regulation BGV A3 • Top mounting with additional terminal cover, sealable • Control panel installation using mounting kit No. 907 0 001 • Undetachable hinged cover with possibility of keeping the memory card OBELISK top2, sealable 35.8 35.8 128.2 * Other TR 612 top2 Common technical data: Nominal voltage: 230–240 V~, +10 %/–15 % Frequency: 50–60 Hz Type of contact: changeover switch Contact: independent of mains phase (zero cross switching) Opening width: < 3 mm Contact material: AgSnO Max. switching capacity: 16 A, 250 V~, cos ϕ = 1 10 A, 250 V~, cos ϕ = 0.6 Min. switching capacity: 10 mA at 230 V AC 100 mA at 12 V AC/DC Power consumption: typ. 3 VA Incandescent lamp load: 2600 W Halogen lamp load: 2600 W Fluorescent lamps: non compensated, series compensated 1000 VA, parallel compensated 730 VA (80 µF) Compact fluorescent lamps: 22 x 7 W, 18 x 11 W, 16 x 15 W, 16 x 20 W, 14 x 23 W Time basis: Quartz Accuracy: ≤ ± 0,5 s/day at +20 °C Shortest switching time: 1 minute (pulse/cycle 1 s) Switching precision: exact to the second Display: backlit LCD display with text line Operating control elements: 4 touch keys Power reserve: about 10 years with autosleep allowing full operation (temperature +20 °C) by non-polluting lithium cell Admissible ambient temperature: –30 °C...+55 °C Housing- and insulation material: self-extinguishing thermoplasts of high temperature resistance Protection class: II according to EN 60 730-1 subject to correct installation Degree of protection: IP 20 according to EN 60 529 Weight: approx. 170 g Test approvals: V 60 * 76.2 * *with terminal cover Type Program Memory locations Programmable every ... Control inputs Memory card OBELISK top2 included in the delivery TR 610 top2 56 1 min – – 24 h/7 d, 1 channel runtime meter, holiday TR 612 top2program 56 1 min – – 2 channels OBELISK top2 programming kit (memory card, plug-in adapter, software) for Windows 2000/XP OBELISK top2 memory card (single) Terminal cover for wall mounting, sealable 32 Switching contacts Nominal current at 250 V~ Order No. 1 changeover switch 16 (10) A 610 0 100 2 changeover switches 16 (10) A 612 0 100 907 0 409 907 0 404 907 0 064 Socket devices Analogue socket timers n-timer be NT year IE G U A R A A NT EE Jahre GAR theben-timer 26 day Function: • C ompact time program connector e.g. for circulation pumps • Without connecting lead for direct insertion in socket • Standard electrical devices, lights, washing machines etc. can automatically be switched on or off as required • Simple program setting via folding segments • Manual switch for instantly switching connected electrical devices on or off without affecting the subsequent program sequence • ON/OFF status display 26 the 7d 24 h theben-timer 26 with segments • Daily time program can be set at 15 min segments theben-timer 27 with segments • Weekly time program can be set at 2 hour segments theben-timer 26 IP 44 with splash guard • D aily time program can be set at 15 min segments • Splash guard for wet rooms and outdoors • Permissible ambient temperature: –40 °C... +55 °C • Clear plastic cover theben-timer 26 IP 44 Technical data: Nominal voltage: 230 V, ± 10 % Frequency: 50 Hz Power consumption: max. 0.8 VA Contacts: Opening width less than 3 mm (µ) Contact material: Solid silver Switching capacity: 16 A, 230 V~, cos ϕ =1 4 A, 230 V~, cos ϕ =0.6 Time accuracy: in accordance with mains frequency Permissible ambient temperature: -10 °C... +55 °C, theben-timer 26 IP 44: –40 °C... +55 °C Housing and insulation material: high-temperature resistant, self-extinguishing thermoplastic Protection class: I in accordance with EN 60 730-1 Protection rating: IP 20 in accordance with EN 60 529 theben-timer 26 IP 44 in accordance with EN 60 529 Test approvals: national and international according to type of device V T W F A Weight: approx. 160 g Type timing disc Special function Program ability of all ... Shortest switching segments Housing colours: Nominal current Switching interval at 230 V~ Order no. theben-timer 26 theben-timer 26 IP 44 theben-timer 27 15 minutes 15 minutes 2 hours 15 minutes 15 minutes 2 hours 026 0 030 026 0 855 027 0 930 24 h 24 h 7 days Switching pre-selection Switching pre-selection Switching pre-selection 96 96 84 white white white 16 (4) A 16 (4) A 16 (4) A Socket devices Digital time program connector 7d 24 h theben-eltimo 020 S DCF Type Program Memory locations Technical data: Nominal voltage: 230 V~, ± 10 % Frequency: 50 Hz Power consumption: max. 5 VA Contact: Opening width less than 3 mm (µ) Contact material: Ag Sn O Switching capacity: 16 A, 230 V~, cos ϕ =1 2 A, 230 V~, cos ϕ =0.6 Time based on: Quartz/DCF synchronized Time accuracy: ≤ ± 1 s/day at 20 °C (quartz) Switching accuracy: to the second/radio signal Display: LCD display of time, switching time, switching status, manual and random operation Permissible ambient temperature: -10 °C...+40 °C Protection class: II in accordance with EN 60 730-1 for housing Protection class: I for plug system Protection rating: IP 20 in accordance with EN 60 529 Weight: approx. 170 g Other theben-eltimo 020 S • Electronic digital timer in modern design • Daily and weekly program with 36 available switching times and free weekday block formation • Automatic summer/winter time switchover • Simple operation via keys for weekdays (d), hours(h) and minutes (m) as well as keys for entering time (E), program entry (Prog), random switching(z) and manual switching (i) • Random switching: Power-on time ranges from 10–120 min • Manual switch for or early switching on or off and permanent operation • Switching status display • Mains independent program entry • Permanent program storage via EEPROM • Power reserve via NiMH rechargeable battery: 500 hours life • 3500 W switching capacity DCF77 2 theben-eltimo 020 S DCF • as above but includes DCF77 radio receiver • Automatic summer/winter time switchover • 33 memory locations Mains independent Program storage Program Switching times ability of all ... theben-eltimo 020 S 24 h/7 days 36 Random operation 500 h 1 minute NiMH rechargeable battery . theben-eltimo 020 S DCF 24 h/7 days 33 Random operation 500 h 1 minute NiMH rechargeable battery . housing colour Nominal current at 230 V~ Order no. from 1 min to 24 h light blue 16 (2) A /. 1 min, random operation 020 0 000 from 1 min to 24 h light blue 16 (2) A /. 1 min, random operation 020 0 300 33 Front panel/distributor installation Operating hours counter 99,999 h Operating hours counter for monitoring burners, heating pumps etc. BZ 142, BZ 143 Function: • Operating hours counter with synchronous motor drive • For installation on control panel or wall • Versions for direct voltage with quartz-controlled stepper motor • Counter range up to max. 99,999.99 hours • Progress display BZ 142/143 Design BZ 142-1, BZ 143-1: • Front panel devices with click-in or stretch clamp supports for walls up to a maximum of 10 mm thick • Clamp or flat plug connection 6.3 mm BZ 142-3 with plug-in base Design BZ 142-3: • with plug-in base for wall installation (terminal cover required) • Plug-in base with quick fastening for 35 mm profile rails (DIN EN 50 022) • Terminal screws • Contact protection to comply with accident prevention regulation BGV A3 • Housing colour: anthracite Technical data: Operating voltage: 230 V~, ± 10 % Special voltage: See appendix: Frequency: 50 Hz Power consumption: approx. 1 VA Permissible ambient temperature with BZ 142/143: –20 °C... +70 °C with BZ 145: –10 °C... +70 °C Counting range: 99,999.99 hours without reset Number size: 1.5 x 3.5 mm,white on black, decimal places black on white Protection class: II in accordance with EN 60335-1 subject to designated installation Protection rating with BZ 142/143: Front frame IP 65 in accordance with EN 60529 with BZ 145: IP 65 in accordance with EN 60 529 Test voltage: 2500 V~ winding and contact versus mass Weight with BZ 142/143: approx. 50 g with BZ 145: Approx. 70 g Design BZ 145: • Standard housing 45 x 35 x 60 mm in accordance with DIN 43 880 • Distribution installation device with quick fastening for 35 mm profile rails (DIN EN 50022) • Top mounting with additional terminal box cover plate, sealable • Control panel installation with assembly kit - no. 907 0 001 • Contact protection to comply with accident prevention regulation BGV A3 • Captive terminal screws BZ 145 Dimension diagrams in accordance with DIN 43 880 65,5 60 52,9* 45 85,85 128,2* Other 35,3 60* 72,5 *with terminal box cover plate Type Counting range Installation BZ 142-1 99,999.99 h Front plate mm Front panel installation with spring closer or terminal clamps 48 x 48 (order no. 907 0 043) Integrated part mm Order no. 46 x 46 142 0 721 Baffle 72 x 72 mm for BZ 142-1 Baffle 55 x 55 mm for BZ 142-1 907 0 074 907 0 041 BZ 142-3 99,999.99 h 142 0 723 Plug-in socket (order no. 907 0 042) with quick fastening 48 x 48 for 35 mm standard mounting rail (included) 46 x 46 Additional terminal cover required for wall installation BZ 143-1 99,999.99 h Front panel installation with click-in or stretch clamp fixings (order no. 907 0 043) incl. 52 x 52 46 x 46 or Ø 50 BZ 145 99,999.9 h Distributor installation with quick fastening for 35 mm profile rails 35 x 45 35 x 45 (depth 60) Terminal box cover plate for top mounting, sealable 34 907 0 075 143 0 721 145 0 000 907 0 064 KNX Room thermostat and multifunction display 35 Wall-mounted Room thermostat and multi-function display VARIA 826 KNX Room temperature controller with display and integrated time switch (clock thermostat). • E asy to clean and scratchproof glass cover in white • E asy to use aluminium pushbuttons. • B ackground lighting, dimmable • Integrated heating control and, if required, control of cooling/ventilation systems New New Features •U p to 7 different editable display pages • F reely configurable for displaying and controlling functions e.g. light scenes, sun protection systems (40 values/functions) •A utomatic summer/winter time adjustment with power reserve •C ontrols up to 8 rooms via own temperature profiles •W eekly time switch with 8 channels with up to 3 different statuses, e.g. for light, shutters, fans etc. • 3 heating programs •C an be configured as continuous or on/off control •O perating modes: comfort, standby, temperature reduction at night Frost protection •A lso for fan coils, e.g. Theben fan coil actuator •D etails from the Theben weather station can be displayed (with min/max values, e.g. for temperature). • F ree choice of programming via the ETS without plug-in •D isplay of physical address • Reception and display of 14 byte text strings (e.g. music title) • Installation in flush-mounted socket VARIA 826 KNX VARIA 824 KNX Technical data: VARIA 826 KNX Operating voltage: 230 V, 50 Hz, ±10 % Power draw from the mains: < 2.5 VA Bus power draw: <8 mA Bus connection: Bus terminal Display: Dot matrix display with 132 x 72 points Display lighting: LCD with white backlighting, dimmable Display: 8 lines with different functions available e.g. title, switching, dimming, %-value (EIS 6), blinds/shutters, heating/ventilation/air conditioning, 8 bit counter value, temperature, 2 byte value (EIS 5), 8/16 bit counter value Power reserve: 1.5 years Permitted operating temperature: 0 °C... + 45°C Protection rating: IP 20 in accordance with EN 60529 Housing: approx. 93 x 128 x 15 mm (VARIA 826 KNX) approx. 80 x 118 x 17 mm (VARIA 824 KNX) Central functions VARIA 824 KNX as with VARIA 826 KNX but including •W hite plastic housing • L arge keys •D isplay pages can be selected via slide switch Lighting control Conservatory control Settings Product database and manual see www.theben.de 36 4 118 118 17 17 21 80 93.4 128 45.6 18.1 80 KNX Dimensional diagrams Type Order no. VARIA 826 KNX 826 9 200 824 9 200 21 VARIA 824 KNX EIB/KNX program for room temperature control RAMSES 712 KNX Flush-mounted installation not including housing RAMSES 713 S EIB/KNX RAMSES 713 FC KNX RAMSES 712 KNX Individual room thermostat for controlling heating actuators or motorised actuators •Wall installation with integrated bus coupling unit •Optional installation in flush-mounted sockets with rear-ventilated covers (without housing). •An external sensor can be connected to the sensor for floor temperature monitoring. •The RAMSES 712 KNX can be used both as an on/off controller (also combinable). •With 2 binary inputs, can be reconfigured to outputs for connecting LED (with communication object) display of ON/OFF. •Free allocation of functions: Switch/key, dimming, blinds, valuator, counter, LED control •Measurable temperature range -20 °C …+60 °C Technical data: Operating voltage: Bus voltage (< 10 mA) Permitted operating temperature: –5 °C … + 45 °C Output with LED configuration: Low current 1 mA (LED 1 mA types) Max. interface extension: 5 m Protection class: II Protection rating: IP 20 Dimensions: 74 x 74 x 28 mm RAMSES 713 S EIB/KNX Continuous individual room controller with bus coupling unit. Available functions: continuous control or on/off control, heating (radiator, underfloor heating), 2 stage heating, heating and cooling • Manual switch for presence or operation mode: comfort, standby, temperature reduction at night, frost protection • Inputs can also be used for external temperature sensor/ floor temperature limiters, window contacts, presence detectors Technical data: Setting range: +10 °C…+28 °C Temperature limitation: through external floor sensor +5 °C…+48 °C Temperature sensor: (IP 65) encapsulated with 4 m connecting cable Operating voltage: Bus voltage (≤ 10 mA) Protection rating: IP20 in accordance with EN 60529 Housing: 80 x 84 x 27 mm RAMSES 713 FC KNX Individual room temperature control for controlling fan coil heaters •Manual switch can be used as operation mode selector for OFF, auto or fan stages 1,2 or 3. •LEDs display heating (red) or cooling (blue) status or whether the desired temperature has been reached • Inputs can also be used for external temperature sensor/ floor temperature limiters, window contacts, presence detectors Technical data: Operating voltage: Bus voltage (≤ 10 mA) Setting range: 10 °C… 28 °C Measuring range: 0 °C… 40 °C Temperature limitation: through external floor sensor 5 °C…48 °C Temperature sensor: (IP 65) encapsulated with 4 m connecting cable Protection rating: IP 20 in accordance with EN 60529 Housing: 80 x 84 x 27 mm FCA 1 KNX FCA1 actuator, for 1-3-stage control of fan coils with heating or cooling valve Control of on/off valve and 3 point valve additional relay possible for control of either an electric heater bank or an electric cooler bank. For 2- or 4 pipe systems Window contact and condensation monitoring Technical data: Operating voltage: 230 V AC, ±10 %, 50-60 Hz Power draw: < 3 VA Switching capacity valves (triacs): 0.5 A (24–230 V AC) Switching capacity, additional relay: 16 A Switching capacity, fan relay: 8 A Permissible ambient temperature: -5 °C ... +45 °C Protection rating: IP 20 in accordance with EN 60529 Housing: 90 x 72 x 60 mm (4 TE), KNX FCA 1 KNX Fan coil actuator Type Function Order no. RAMSES 712 KNX RAMSES 713 S KNX RAMSES 713 FC KNX FCA 1 KNX Floor sensor KNX Individual room thermostat without rotary control Individual room thermostat with rotary control Fan coil room thermostat with rotary control Fan coil actuator IP 65, 4 m connecting lead 712 9 200 713 9 201 713 9 202 492 0 200 907 0 321 37 EIB/KNX program for room temperature control HMT 6 KNX 6 channel heating actuator for control of thermal drives HMT 6/HMT 12 KNX Cheops drive KNX Cheops control KNX HMT 12 KNX 12 channel heating actuator for control of thermal drives • Housing is particularly designed for installation in heating circuit distributors • Straight forward wiring of drives (24 V~) • Can be installed directly on a wall or a rail in the heating circuit distributor • Integrated power unit with mains plug for connection of up to13 thermal drives (24 V~) • Choice of constant or variable actuating values • Summer mode prevents unintentional heating in the summer (valve protection option in summer mode) CHEOPS control KNX Motorised drive with independent control and temperature recording • Independent room temperature control, manual operation possible via 2 keys on the device • Display via 5 LED’s • Fully automatic valve stroke recognition which dynamically adjusts the set path • External temperature sensor or temperature limiter for underfloor heating • Simple installation via rastering on valve adapter (valve adapter included in the scope of supply for all current valves) CHEOPS drive KNX• Motorised drive as above but without control • Stroke display (setting position) via 5 LEDs (red) HMG 4 KNX (basic device) • 4 channel heating actuator HME 4 KNX (upgrade device) • 4 channel upgrade module (for upgrading to max.12 heating channels) KNX HMG 4 KNX Basic device, 4 channels HME 4 KNX Upgrade device , 4 channels Description The heating actuator optimises the effect when using room temperature controls in conjunction with thermal actuators and enables the integration of a boiler control. Circulation pump can be directly controlled via the actuator. • S ilent semiconductor switch • 4 floating outputs 24–250 V AC •U p to 5 positioning actuators per channel •C ontinuous or switching control variable selectable • E mergency program in case of bus and telegram failure • S ummer mode and valve protection •M inimum and maximum actuating value can be set •D etermination of maximum control variables in all channels, including boiler control, enables energy savings of up to 30 % Technical data: Operating voltage: 230 V/24 V AC Max. power draw: 50 W Fuse: T 2 A Max. number of drives: 13 Heating program options: 2 Dimensions H/W/L: 70 x 75 x 302 mm Protection class: II subject to designated installation Protection rating: IP 20 in accordance with EN 60529 Flexible lead*: 1.0–1.5 mm2 * Drive leads can be fitted ex works with wire end sleeves. ALPHA 4 24 V~ actuator • See page 39 for technical details of actuator Technical data: Operating voltage: Bus voltage Emergency program: Available position Operating temperature: 0 °C ...+50 °C Medium temperature: ≤100 °C Protection rating: EN 60529 – drive: IP 21– control: IP 20 Protection class: III, EN 60730-2-14 Max. valve stroke: 7,5 mm Detection of valve limit stops: Automatic Approved valves: Actuator with valve adapter for Danfoss RA, Heimeier, MNG, Schlösser from 3/93, Honeywell Braukmann, Dumser (distributor), Reich (distributor), Landis + Gyr, Oventrop, Herb, Onda Technical data: Voltage: 230 V AC, ± 10%, 50 Hz Power take up: < 2.5 VA Power supply from the bus (basic module only) Power supply: < 10 mA (incl. 2 upgrades) Connection: KNX bus terminals Output: Triac Quantity: 4 Switching capacity: 0.5 A, up to 5 therm. Actuator/output Connection cross-sections: solid 0.5 mm2 (Ø 0.8) to 4 mm2 strand with wire end sleeve: 0.5 mm2 to 2.5 mm2 Permissible ambient temperature: -5 °C ... +45 °C Protection class: II subject to designated installation Protection rating: IP 20 in accordance with EN 60529 Housing: 45 x 72 x 60 mm (4 TE) Please request the new KNX catalogue with lots of other solutions for building automation. Type Channels Output HMT 6 KNX 6 6 x Triac 24 V AC HMT 12 KNX 12 12 x Triac 24 V AC CHEOPS control KNX With valve adapter for: Danfoss, RA, Heimeier, MNG, Schlösser from 3/93, CHEOPS drive KNXHoneywell,Braukmann, Dumser (distributor), Reich (distributor), Landis + Gyr, Oventrop, Herb Operating voltage 230 V/50 Hz and Bus 230 V/50 Hz and Bus Bus Bus Order no. 490 0 273 490 0 274 732 9 201 731 9 200 Type Special function Output Nominal current at 250 V~ Order no. HMG 4 EIB/KNX HME 4 EIB/KNX 4 x 2 A 4 x 2 A 491 0 210 491 0 211 38 heating actuator basic device, 4 rotary switches, 4 LED displays 4 x Triac Add-on device, 4 rotary switches, 4 LED displays 4 x Triac Accessories: Actuator for individual room control ALPHA 4 actuator for individual room control enables customised temperature reduction Theben provides the elegant solution for new build and modernisation. The reliable RAMSES clock thermostat combined with an electro-thermal actuator makes it possible to upgrade existing systems to individual room control. Extremely easy to install as the heating pipes do not need to be changed. Thanks to a wide range of adapter pieces, these electro-thermal actuators can be installed on practically any radiator. Any Theben clock thermostat can be combined with one or more drives to control rooms such as, for example,living rooms, bedrooms, kitchens or offices to meet your individual requirements. Automatic reduction in room temperature when empty or at night makes it possible to reduce energy consumption by up to 20 %. A Theben clock thermostat or thermostat is required for controlling the following actuators. ALPHA 4 actuator VA 78 ALPHA 4 230 V~ actuator • Attractive actuator for radiators, heating circuit distributors or individual heating circuits • "First open function" for easy installation and heating start up • Plug-in installation on valve adapters • 100% protection against damaging drives through leaking valves • Function and adjustment checking • Protection against disassembly by means of removable SaveGuard • Guaranteed surge protection VA 80 Valve adapter (not included in the scope of supply) ALPHA 4 24 V actuator • Actuator as before, but for 24 V AC/DC Common technical data: Operating voltage: 230 V AC, 50/60 Hz 24 V, 0–60 Hz Function principle: Silent, flexible element Valve without current: Closed Switch-on power level: max. 300 mA for max. 200 ms max. 250 mA for max. 2 min Nominal output: 1.8 W Closing/opening times: Approx. 2.5 min Stroke: 4 mm Spring tension: 100 N, ± 5 % Permissible ambient temperature: 0 °C… 60 °C Storage temperature: –25 °C… 60 °C Protection rating: IP 54 in accordance with EN 60529 Protection class: II in accordance with EN 60 730-1 Length of insertable connection line: 1000 mm Housing colour: White (RAL 9003) Housing: 60 x 44 x 61 mm (H/W/L) Unscrew at valve thermost ua- Attachact tor Installation without affecting the water supply. Further valve adapters on request: Valve adapter VA 78 • Valve adapter for Danfoss RA Valve adapter VA 80 • Valve adapters for Onda, Schlösser(from 1993), Oventrop (M30 x 1.5), Heimeier, Herb, Therm-Concept, Frank, Roth (distributor), Dinotherm (distributor). Radiator heating control: VA 02 M 30 x 1.5 Velta VA 16 M 28 x 1.5 Herz VA 16 H M 28 x 1.5 Poly Therm VA 26 flange Giacomini VA 59 Danfoss RAVL VA 81 M 30 x 1.5 Cosmotherm, Cosmoline (GC distributor), Strawa Individual under-floor heating circuit control: 1 2 3 4 5 6 7 Living room Kitchen Bathroom Work room 230 V~ 24 V~ L1 N sing isolation SELV when u ormer transf Connection example of RAMSES clock thermostat Type Order no. ALPHA 4 230 V~ actuator 907 0 438 Actuator ALPHA 4 24 V907 0 439 Valve adapter VA 78 907 0 436 Valve adapter VA 80907 0 437 39 KNX R N Subject to technical changes and improvements. 2409 9900606 Theben AG Hohenbergstraße 32, 72401 Haigerloch, GERMANY Postfach 56, 72394 Haigerloch, GERMANY Phone +49 (0)74 74/6 92-0Fax +49 (0)74 74/6 92-150 E-mail: [email protected], www.theben.de
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project