THEBEN Theben-HKL

Add to my manuals
40 Pages

advertisement

THEBEN Theben-HKL | Manualzz
english
H eating
V entilation
A ir conditioning
New
• Flush/wall-mounted room thermostats
• Analogue clock thermostats
• Digital clock thermostats
• Radio-controlled thermostats
• Actuators
• 3 point controller
• Mixer control
• Service water control
• Weather-dependent control
• Open Therm
• KNX heating control
NEW PRODUCTS 2009
Digital clock thermostat
with multi-function input
RAMSES 832 top2
• Presence detector, window contact
or floor sensor input
• Flat housing (21 mm)
• Backlit display
• Text guidance
CO2 sensor for climate control
with 2 stage control, relay outputs +
0 – 10 V proportional outputs for CO2, temperature
and relative humidity.
2
Analogue clock thermostats
with daily and weekly programs
Pages 10 – 11
Digital clock thermostats
with daily and weekly programs
with optimisation
Wall installation
with floor sensor
with 3 point control
with radio control
Pages 12 – 14
Page 15
Pages 16 – 17
Page 18
Pages 19 – 20
Pages 21 – 23
Heating controller
with service water control
Pages 24 – 25
Digital clock thermostats
Rail mounted
Flush-mounted installation
Connection diagrams
Page 26
Page 27
Pages 28 – 29
Sensors
CO2 sensors
Humidity stat
Page 30
Page 31
Digital time switches
Wall-mounted, rail mounted
Page 32
Timer switches
Socket devices
Page 33
Operating hours counter
analogue/digital display
Page 34
KNX heating control
thermostats
Pages 36 – 37
KNX actuators
for fan coils
for underfloor heating, rail mounted
Page 37
Page 38
KNX actuators
without control, with control
thermal 24V/230 V~
Page 38
Page 39
Digital controllers
Page 6
Page 7
Pages 8 – 9
Other
Wall-mounted
Flush-mounted installation
Electronic room thermostats
KNX
Analogue room thermostats
Analogue controllers
Contents
3
Order number
Page number
Replacement device
without front cover,
order no.
701 0 001
P. 6
3/4
230 V
50 Hz
•
702 0 001
P. 6
3/4
230 V
50 Hz
•
703 0 001
P. 6
3/4
230 V
50 Hz
•
704 0 001
P. 6
3/4
230 V
50 Hz
•
705 0 001
P. 6
4/5
230 V
50 Hz
•
706 0 001
P. 6
4/5
230 V
50 Hz
•
707 0 001
P. 6
3/4
230 V
50 Hz
•
708 0 001
P. 6
4/5
230 V
50 Hz
•
709 0 001
P. 6
2/3
230 V
50 Hz
•
741 0 130 741 0 131
P. 7
4/5
230 V
50 Hz
•
746 0 130 746 0 131
P. 7
3/4
230 V
50 Hz
•
748 0 130 748 0 131
P. 7
Heating
3/4
230 V
50 Hz
•
714 0 002
P. 8
Heating
Heating
6/7
230 V
50 Hz
•
714 0 016
P. 8
•
714 0 017
P. 8
751 0 131
P. 9
Flush-mounted
housing
Operating voltage
•
Wall-mounted
Connecting wires
230 V
50 Hz
Display
2/3
Manual switch
Temperature reduction input
Underfloor
temperature sensor
Room temperature
sensor
Thermostats
Temperature
setting range
Model comparison
Analogue clock thermostats, wall-mounted
RAMSES 701
5…30°C
•
RAMSES 702
5…30°C
•
RAMSES 703
5…30°C
•
RAMSES 704
5…30°C
•
RAMSES 705
5…30°C
•
RAMSES 706
5…30°C
•
RAMSES 707
5…30°C
•
RAMSES 708
5…30°C
Heating/
cooling
•
RAMSES 709
5…30°C
Heating/
cooling
•
•
Additional Additional
heating
heating
Heating
•
Heating
Heating
Heating +
Additional Additional
heating
heating
•
Comfort
reduction
automatic
Heating
Analogue room thermostats, flush-mounted
installation
RAMSES 741 RA
5…30°C
•
RAMSES 746 RA
5…30°C
•
RAMSES 748 RA
5…30°C
Heating/
cooling
•
•
Heating
Heating
Electronic room thermostats, wall mounted/
flush-mounted
•
RAMSES 714
5…30°C
RAMSES 714 A
10…30°C
•
RAMSES 714 A/FH
5…30°C
•
Heating
Heating
6/7
230 V
50 Hz
RAMSES 751 RA
10…30°C
•
Heating
Reduction
6/7
230 V
50 Hz
•
•
Accessories:
Actuators for individual room control
4
ALPHA 4 230 V~
Actuator suitable for all RAMSES controllers. Opens without current. Humidity and overload protection. Plug-in 907 0 438
installation plus well as function and adjustment control. Valve adapter required).
P. 39
ALPHA 4 24 V
Positioning actuator as before, but for 24 V AC/DC low voltage.
SELV with use of an isolating transformer e.g. for bathrooms and sanitary facilities
P. 39
907 0 439
(Hand
adjustment
range)
3/4
Segment 722 0 801
Prog. 24 h 782 0 801
P. 10 - 11
1
5/30 min Day tappet
15 min
I
Battery
365 d
(Hand
adjustment
range)
3/4
Segments
5k reduc- 784 0 030
784 0 801
tion
P. 10 - 11
6…30°C
1
5/30 min Day tappet
I
230 V~
3d
(Hand
adjustment
range)
3/4
Reduction 721 0 030
control 725 0 030
only
P. 10 - 11
24 h/
7d
6…30°C
3
I
230 V~
battery
± 1 h
auto
3/4
2
24 h/
7d
6…30°C
230 V~
battery
± 1 h
auto
3/4
2
RAMSES 722 S
RAMSES 782 S
24 h
6…30°C
1
15 min
RAMSES 784
RAMSES 784 S
24 h/
7d
6…30°C
RAMSES 721
RAMSES 725
24 h
RAMSES 812 top2
RAMSES 811 top2
RAMSES 832 top2
RAMSES 831 top2
Memory locations
Day tappet
Page number
230 V~
3d
5 min
30 mins
Order number
Connection for
operating devices
(wires)
I
1
Special functions
Automatic summer/winter time
Segments
6…30°C
TR top text guidance
P. 10 - 11
24 h/
7d
Manual switch
Changeover range 722 0 030
Prog. 24 h 782 0 030
/7d
Programmable
every …
3/4
Quantity
Switching programs
(Hand
adjustment
range)
Room temperature setting range
Operating voltage
Power reserve
Switching program
I
230 V~
3d
RAMSES 722
RAMSES 782
Clock
thermostats
Analogue
Clock thermostat
Digital
clock thermostats
1 min.
24
Mains
812 0 132
Battery
811 9 132
Illuminated
display
5 temp. controls
3 indiv.
programs
832 0 132
I
831 9 132
The world's finite
natural resources make it essential
to3/4use ener812 0 032
RAMSES 812 top
24 h/ 6…30°C
230 V~ ± 1 h
22
1 min.
3
I
7d
battery auto
RAMSES 811 top
gy responsibly. Therefore, saving energy is a top priority2 for The-811 9 032
832 0 032
3/4
RAMSES 832 top
24 h/ 6…30°C
230 V~ ± 1 h
3 of1 min.
I
ben
all its22products
and
alsoauto
for all
other
7d
RAMSES
831 topin the development
battery
831 9 032
2
818 0 035
± 1 h
24 h/ company
230 V~ innovative,
activities
of the
and
Our
func6…30°C
1 min. its22employees.
RAMSES
818 top
5/6
3
I
7d
auto
818 0 036
5h
tional and high
quality systems for timing, lighting
and air condi816 9 032
RAMSES 816 top
230 V~ ± 1 h
24 h/ 6…30°C
2 (Bus)
22
1 min.
3
I
7d
RAMSES 817 top
auto
5h
817 9 032
tioning are designed to help users save energy and money.
3
1 min.
24
Mains
Battery
24 h/
7d
± 1 h
auto
3/4
2
Remote sensor
for underfloor
heating
6 A/16 A
P. 18
Flushmounted
installation 822 0 031
22
1 min.
3
I
823 0 031
»Energy saving ideas« – This brochure provides good examples
RAMSES
top
820 9 011
of820our
active 24commitment
to
the22issues of energy,
environmental
2
± 1 h
h/ 6…30°C
Battery
3
1 min.
I
7
d
auto
821 9 011
2
RAMSES 821 top
awareness and responsibility.
RAMSES 823 top
6…30°C
P. 16
P. 17
Ext. sensor
230 V~
5h
P. 12 - 14
5 temp. controls
3 indiv.
programs
3 point control
or 2 stages
RAMSES 822 top
P. 12 - 14
Wall installation
Flushmounted
installation
Wall installation
P. 19 - 20
P. 27
P. 27
Digital clock thermostat
with radio control
RAMSES 813 top2 HF
Set AChairman
/ Set S
Thomas Goes247 dh/
of the Board
6…30°C
3
1 min.
24
RAMSES 833 top2 HF
Set 1/ Set 2
24 h/
7d
6…30°C
3
1 min.
RAMSES 813 top HF
Set A / Set S
24 h/
7d
6…30°C
3
RAMSES 813 top HF
Set 1/ Set 2
24 h/
7d
6…30°C
3
I
Battery
± 1 h
auto
wireless
Receiver
Wall-mounted
Intermediate
connector
24
I
Battery
± 1 h
auto
wireless
1 zone
2 zones
833 9 501
833 9 502
P. 15
1 min.
22
I
Battery
± 1 h
auto
wireless
Receiver
Wall-mounted
Intermediate
connector
813 9 403
813 9 405
P. 21
1 min.
22
I
Battery
± 1 h
auto
wireless
813 9 503
813 9 505
1 zone
813 9 401
2 zones
813 9 402
P. 15
P. 22 - 23
Heating control, weather or room temperature dependent
with service water control
RAMSES 855 top
24 h/
7d
6…30°C
3
1 min.
22
I
5h
± 1 h
auto
2 (Bus)
4 channel controller
Service water
control
Circulation control
Mixer control
855 9 032
P. 24
RAMSES 855 top2 OT
24 h/
7d
6…30°C
3
1 min.
24
I
5h
± 1 h
auto
2 (Bus)
4 channel controller
Service water
control
Circulation control
Mixer control
855 9 132
P. 25
5
Wall-mounted
Room thermostats
5-30 °C
Analogue controllers
Function:
Room thermostat with thermal recirculation, suitable for all
heating types, e.g. gas, water, electric heating with central/
individual room controls.
• Setting controller from +5 °C to +30 °C with mechanical
setting limit or detection
• RAM 708/709 is also suitable for air conditioning devices
RAMSES 701
RAMSES 702
• Integrated temperature reduction (approx. 4 K) possible via
external control (e.g. timer SYN 161 h, TR 610 top) possible.
RAMSES 701
RAMSES 703 as RAMSES 702, but with internal setting
• Temperature cannot be set externally. Temperature is set
inside the device at start-up
Technical data:
Operating voltage: 230–240 V~, +10 %/–15 %,
50–60 Hz
NC contact: 10 (4) A, 230 V~max. 10 Theben actuators
-can be controlled (see page 39)
Two-way switch: 10 (4) A (heating), max. 10 Theben
actuators can be controlled (see page 39), 5 (2) A (cooling)
Temperature range: +5 °C... +30 °C
Switching differential, dynamic: approx. 1 K, thermal
recirculation
Protection class: II in accordance with EN 60730-1
subject to designated installation
Protection rating: IP 30 in accordance with EN 60529
Housing colour: pure white (RAL 9010)
Test approvals: V
Weight: Approx. 80 g
Connection diagrams see page 29.
RAMSES 704
• Switch for additional heating ON/OFF+indicator lamp
RAMSES 705
• Switch for heating ON / OFF
RAMSES 706
• Integrated temperature reduction (approx. 4 K) possible
via external control (e.g. timer)
• Switch for heating ON / OFF + indicator lamp
RAMSES 706
RAMSES 707
• Switch for heating ON / OFF
• Switch for additional heating ON / OFF+indicator lamp
RAMSES 708
• Heating / cooling two-way switch
RAMSES 709
• Heating / cooling two-way switch
• 3-way selector switch for: Comfort operation, reduced
operation, external reduction (time-controlled with timer)
• Indicator lamp
RAMSES 707
70,7
Dimensional diagrams
75
5,5
24
28
83
11,5
Adapter plate for flush-mounted socket
Type
Operating voltage
Temperature
range r/ m
Nominal current
at 230 V~
Order no.
RAMSES 701 230 V/50–60 Hz
+5 °C to +30 °C
1 K
2-/3 conductors
RAMSES 702 230 V/50–60 Hz
+5 °C to +30 °C
1 K
3/4 way conductors
1 NC contact
10 (4) A
701 0 001
1 NC contact
10 (4) A
RAMSES 703 230 V/50–60 Hz
+5 °C to +30 °C
1 K
702 0 001
3-/4 conductors
1 NC contact
10 (4) A
RAMSES 704 230 V/50–60 Hz
+5 °C to +30 °C
1 K
703 0 001
3/4 way conductors
1 NC contact
10 (4) A
704 0 001
Switching differential Connection
Contact
dynamic approx.
RAMSES 705 230 V/50–60 Hz
+5 °C to +30 °C
1 K
3/4 way conductors
1 NC contact
10 (4) A
705 0 001
RAMSES 706 230 V/50–60 Hz
+5 °C to +30 °C
1 K
4/5 way conductors
1 NC contact
10 (4) A
706 0 001
RAMSES 707 230 V/50–60 Hz
+5 °C to +30 °C
1 K
4/5 way conductors
1 NC contact
10 (4) A
707 0 001
RAMSES 708 230 V/50–60 Hz
+5 °C to +30 °C
1 K
3/4 way conductors
1 two-way switch
10 (4) A/5 (2) A
708 0 001
RAMSES 709 230 V/50–60 Hz
+5 °C to +30 °C
1 K
4/5 way conductors
1 two-way switch
10 (4) A/5 (2) A
709 0 001
Adapter plate for flush mounted socket 79 x 79 mm
6
907 0 480
Flush-mounted
Room thermostats
5-30 °C
RAMSES 746 RA (with frame)
Technical data:
Operating voltage: 230–240 V~, +10 %/–15 %,
50–60 Hz
NC contact: 10 (4) A, 230 V~max. 10 Theben actuators
-can be controlled (see page 39)
Two-way switch: 10 (4) A (heating), max. 10 Theben
actuators can be controlled (see page 39), 5 (1) A (cooling)
Temperature range: +5 °C... +30 °C
Switching differential, dynamic:approx. 0.5 K, thermal
recirculation
Electrical connection: screwless terminals for 2 x (1.5
mm2–2.5 mm2) wire
Protection class: II in accordance with EN 60730-1
subject to designated installation
Protection rating: IP 30 in accordance with EN 60529
(with cover, installed)
Housing colour: pure white gloss (RAL 9010)
Test approvals: V
Weight: Approx. 80 g
RAMSES 741
• NC contact
50
RAMSES 746
• NC contact
• Integrated temperature reduction (approx. 4 K) possible
via external control (e. g. timer)
• Switch for heating ON / OFF + indicator lamp
Analogue controllers
Function:
Room temperature with thermal recirculation for installation
in flush-mounted sockets. Ideal control for modernisation
and new build projects as it is easy to integrate and fits in
perfectly in the domestic environment.
• Setting range +5 °C to +30 °C
• Ability to limit temperature range using the control
knob
• Simple connection via screwless terminals
• Available as replacement device without frame, cover
plate and setting button, incl. protective cap
• Frame, central part and setting button available as
accessories
• Central part (50 x 50) fits in nearly all programs via
switch manufacturers adapter frame
Flush mounted digital timer see main catalogue.
Connection diagrams see page 29.
RAMSES 748
• Heating / cooling two-way switch
RAMSES 746(without cover, rotary switch and
frame)replacement device for area switch programs
Central part with
switch section and
setting button
Frame
Dimensional diagrams
80,5
70,6
50
24,5
60
56
56
50,5
19
für Gerätedose nach DIN 49073
Temperature range
adjustabler/ m
19
für Gerätedose nach DIN 49073
60
Type
Front
Operating voltage
24,5
50,5
43,5
70,6
Central part without
switch section and
setting button
Switching differential Connection
Contact
dynamic approx.
Nominal current
at 230 V~
Order no.
RAMSES 741 Without cover 230 V/50–60 Hz
+5 °C to +30 °C
0,5 K
3/4 conductors
1 NC contact
10 (4) A
741 0 130
RAMSES 746 Without cover 230 V/50–60 Hz
+5 °C to +30 °C
0,5 K
4-/5 conductors
1 NC contact
10 (4) A
746 0 130
RAMSES 748 Without cover 230 V/50–60 Hz
+5 °C to +30 °C
0,5 K
3/4 way conductors1 two-way switch
10 (4) A/5 (1) A
748 0 130
RAMSES 741 RA
With cover 230 V/50–60 Hz
+5 °C to +30 °C
0,5 K
2/3 way conductors1 NC contact
10 (4) A
741 0 131
RAMSES 746 RA
With cover 230 V/50–60 Hz
+5 °C to +30 °C
0,5 K
4-/5 conductors
10 (4) A
746 0 131
RAMSES 748 RA
With cover 230 V/50–60 Hz
+5 °C to +30 °C
0,5 K
3/4 way conductors1 two-way switch
10 (4) A/5 (1) A
748 0 131
1 NC contact
Central part with switch section + setting button for RAMSES 746
907 0 601
Central part without switch section + setting button for RAMSES 741 and RAMSES 748
907 0 602
Frame
907 0 603
7
Wall-mounted
Electronic room thermostats
5-30 °C
Analogue controllers
Function:
Modern designed electronic room thermostats can easily
be exchanged for currently installed thermostats. Surface
mounting or directly on a flush mounted housing; also
suitable for large area switching programs. Depending on
the make an adapter plate (79 x 79 mm) may be required
to completely cover the flush mounted housing.
Technical data:
Operating voltage: 230 V, +10 %/–15 %, 50 Hz
Protection class: II in accordance with EN 60730-1
subject to designated installation
Protection rating: IP 20
Housing colour: pure white (RAL 9010)
RAMSES 714:
Setting range: +5 °C…+30 °C
Control accuracy: ± 0.25 K
NC contact: 8 A/230 V~
RAMSES 714
• Precise electronic two point controller suitable for all
types of heating, e. g. gas, water, electric heating etc.
• Individual room control is possible in combination with
Theben actuators
• Exact temperature setting in the range of +5 °C…+30 °C
• Heating status display via LED
• Integrated temperature reduction (approx. 3.5 K) possible via external control (e. g. timer SYN 160 a, TR 610
top). Temperature reduction can be cut to 2 K by opening a wire bridge
RAMSES 714
RAMSES 714 A:
Setting range: +10 °C…+60 °C
Control accuracy: ± 0.5 K
Sensor cable: Length 4 m, Ø 6 mm, (IP 54)
NC contact: 16 A/230 V~
RAMSES 714 A/FH:
Setting range: +5 °C…+30 °C (+40 °C)
Control accuracy: ± 0.5 K
Sensor cable: Length 4 m, Ø 6 mm, (IP 54)
NC contact: 16 A/230 V~
RAMSES 714 A
Precise electronic on/off controller as with RAM 714 but
including
• External temperature sensor for under-floor heating
(wet rooms or bathroom heating)
• Switchable for the connection of available NTC sensors
(33 KΩ/25 °C)
• Setting range of +10 °C…+60 °C
• Switch for heating ON / OFF
• Sensor cable (IP 54), length 4 m
RAMSES 714 A
10–60 °C
Connection diagrams see page 29.
RAMSES 714 A/FHas RAM 714 A but
• Equipped with selectable underfloor heating temperature limits 40 °C (tiles) or 30 °C (laminates, wood, cork)
• No switch to available NTC sensors
• Setting range of +5 °C…+30 °C (+40 °C)
RAMSES 714 A/FH
Dimensional diagrams
� 74
� 74
� 74 5
5
23.3
28
28
Type
Operating voltage
� 79
5
23.3
RAMSES 714
Combining the aforementioned clock
thermostats with Theben actuators
enables convenient, needs-driven
individual room control. The actuators are
simply screwed onto the individual radiators
or into the heating circuit distributor in underfloor
heating systems.
� 67
� 67
� 67
Individual room control
� 79
� 79
7.5
7.5
7.5
See page 39 for a detailed description.
27.9
32.6
RAMSES 714 A
Adapter plate for flush-mounted socket
Temperature
Connection
Contact
ranger/ m
Nominal current
at 230 V~
RAMSES 714
230 V/50 Hz
+5 °C to +30 °C
2/3 way conductors
1 NC contact
8 A
RAMSES 714 A 230 V/50 Hz
+10 °C bis +60 °C 4/5 way conductors
1 NC contact
16 A
RAMSES 714 A/FH230 V/50 Hz
+5 °C to +30 °C (+40 °C) 4/5 way conductors
1 NC contact
16 A
Adapter plate for flush mounted socket 79 x 79 mm
8
Order no.
714 0 002
714 0 016
714 0 017
907 0 212
Flush-mounted
Electronic room thermostat
Technical data:
Operating voltage: 230 V~, +10 %/–15 %, 50 Hz
NO contact: 16 (4) A, 230 V~
Setting range: +10 °C…+50 °C
Control behaviour: Proportional controller with PWM
(continuous type)
Sensor cable: Length 4 m, diameter 6 mm, extendable
to 50 m
Displays: LED red – controller demands heat
LED green – reduced mode
Protection class: II in accordance with EN 60 529
Protection rating: IP 30
Housing colour: pure white (RAL 9010)
Analogue controllers
RAMSES 751 RA
Precise electronic controller (PWM) with remote
temperature sensor for floor temperature control.
• Ideal controller for underfloor heating
• Floor temperature setting range +10 °C…+50 °C
• Temperature limitation and detection using the setting
button
• Temperature reduction option (3 or 5 K) via external
timer or switch
• Display of temperature reduction and heating ON
• 2-pole mains switch for heating ON/OFF
• Emergency mode for sensor malfunction at
30 % heating
• Connection via screw terminals
• Central part fits nearly all frames using an adapter
frame from the switch manufacturer
RAMSES 751 RA
L N
10–50 °C
L
N
S1
N
Sensor
Sonde
TA
RAMSES 751 RA
Dimensional diagrams
Individual room control
80,5
70,6
45
4
17
3
Combining the aforementioned clock
thermostats with Theben actuators
enables convenient, needs-driven
individual room control. The actuators are
simply screwed onto the individual radiators
or into the heating circuit distributor in underfloor
heating systems.
28
2
5
56
50
See page 39 for a detailed description.
60
für Gerätedose nach DIN 49073
Type
Operating voltage
Temperature
Connection
Contact
range
Nominal current
at 250 V~
Order no.
RAMSES 751 RA
+10 °C…+50 °C
16 (4) A
751 0 131
230 V/50 Hz
6/7 way conductor
NO contact
9
Wall-mounted
Analogue controllers
Analogue clock thermostats
RAMSES 721
RAMSES 722/782/784
10-30 °C 7d 24 h
Function:
Clock thermostats in a low profile design for time-dependent monitoring and control of room temperature. Easy
setting of energy saving temperature reduction at night on
program disc. 24 h segmented timing disc ("S" type) or
optional switchable timing disc for 24 h or 7 days. Suitable
for oil or gas fired heating systems. The clock thermostat
controls recirculation pump, thermal actuator, magnetic
valve, motorised mixer or the gas water heaters directly
via relay contact.
RAMSES 722, clock thermostat in a low profile design
for time-dependent monitoring and control of room
temperature.
• Electronic temperature control
• Operating point and electronic recirculation are set
from the front
• Normal and reduction temperature are set separately,
range +10 °C ... +30 °C
• Party switch and program display
• Selector switch for operating mode:
m Constant reduction temperature
r Constant normal temperature
j Automatic mode
f Frost and plant protection +6 °C
• Synchronous motor drive
• Two way switch 6 (1) A/250 V~
RAMSES 782, as RAMSES 722, except for
• Quartz mechanism, 3 day power reserve
RAMSES 784 S with opened flap and segment program disc
Tappet program disc
Set handto 16.00...
RAMSES 784, as RAMSES 782, except for
• Batteries for 2 or 3 wire connection
• Battery monitoring with battery replacement indicator
via flashing LED
• Silting and pump protection function (option)
RAMSES 721, as RAMSES 722, except for
• 24 h tappet timing disc
• Normal temperature range from +10 °C...+30 °C
• Reduced temperature approx. 5 K lower in relation to
the set comfort temperature
• No selector switch for operation mode
RAMSES 725, as RAMSES 722, except for
• Comfort temperature control through existing
thermostat valves on radiator
• Temperature reduction controlled centrally through
RAM 725 within the range of +10 °C - +30 °C in
accordance with switching program
• Selector switch for 4 operating modes
Technical data:
Clock thermostats are a combination of a timer and a
thermostat (on/off controller). Tappets or segments make
it possible to reduce temperature several times a day.
Segment program disc: 24 hour program, programmable every 15 mins, shortest switching interval 15 mins
Tappet program disc: Adjustable for 24 hour and 7 day
programs.
24 hr program: Programmable every 5 mins, shortest
switching interval 20 mins
7 day program: Programmable every 30 mins, shortest
switching interval 2 hours
Time adjustment: via analogue time display, including
anti-clockwise.
Thermostat: On/off controller, setting range
+10 °C...+30 °C, frost protection +6 °C,
operating point (± 4 K)
Switching differential can be adjusted via
electronic recirculation: 0.4–1.2 K (4...20 mins)
Type RAM 721/725: fixed 1.5 K (20 mins)
Contact: Two way switch, opening width less than 3 mm
(µ), floating, not for SELV
Switching capacity: 6 (1) A/250 V~
Protection rating: IP 20 in accordance with EN 60 529
Protection class: II in accordance with EN 60 730-1
subject to designated installation
Test approvals: national and internationaldepending on
type of device V (RAMSES 721/722/725/782)
Housing dimensions: 90 x 150 x 35 mm
RAMSES 722/721/725 without power reserve
Operating voltage: 230 V~, +10 %/-15 %
Frequency: 50 Hz
Time accuracy: Dependent on mains frequency
RAMSES 782 with power reserve
Operating voltage: 230 V~, +10 %/-15 %
Frequency: 50-60 Hz
Time accuracy: ≤ ± 1 s/day at 20 °C
RAMSES 784 with battery operation
Operating voltage: 2 AA batteries
Time accuracy: ≤ ± 1 s/day at 20 °C
Contact: Two way switch, opening width less than 3 mm
(µ), floating, suitable for SELV
... Remove graduated
ring ...
Actuator for
individual
room control see page 39.
... turn overand clip
into weekly program.
Red tappetsfor normal
temperature, blue
tappets for reduced
temperature
10
Tappets:
red: switches on normal temperature
Order no. 934 3 236
blue: switches on reduction
Order no. 934 3 111
Wall-mounted
Analogue clock thermostats
1
2
3
1
2
3
M
4
5
M
+
L
N
RAMSES 7.. controls recirculation pump, thermal mixer
valve or oil/gas burners
RAMSES 7.. controls motorised mixer valves
60
1
2
3
L
N
RAMSES 784 controls recirculation pump, thermal mixer
valve or oil/gas burners
RAMSES 784 controls motorised mixer valves
I
j
±1h
Flush-mounted socket or wall installation
+
L
N
Functions and plug-in base connection, e.g. RAM 722 s/782 s
-
4
5
L
N
1
2
3
Analogue controllers
10-30 °C 7d 24 h
Control lamp for
heating mode
Program display and
party switch can be
switched by hand to normal
or reduce temperature early
-
Normal temperature controllerfor setting
r comfortable room temperature
m
Energy saving controller for setting reduction temperature, e.g. at night
Time display withadjustable hands for summer/
winter-time correction
R
N
Switching differential adjustable
Selector switch for operating modes
j Automatic program
r continuous normal temperature
m continuous reduced temperature
f Frost and plant protection ( +6 °C)
Operating point
adjustable
Type
RAMSES 722 RAMSES 722 S
RAMSES 782
RAMSES 782 S
Power
reserve approx.
Temperature
ranger/ m
Switching
Connection*
Contact
Display
Program
differential adjustable
Order no.
+10 °C to +30 °C
+10 °C to +30 °C
+10 °C bis +30 °C
+10 °C bis +30 °C
0,4–1,2 K
0,4–1,2 K
0,4–1,2 K
0,4–1,2 K
3 or 4 conductors
3 or 4 conductors
3 or 4 conductors
3 or 4 conductors
1 LED Heating
1 LED Heating
1 LED Heating
1 LED Heating
24 h/7 d tappet
24 h segments
24 h/7 d tappet
24 h segments
722 0 030
722 0 801
782 0 030
782 0 801
RAMSES 784
1 year
+10 °C bis +30 °C
0,4–1,2 K
monitoring
2 or 3 conductors 1 two-way switch 1 LED Battery
24 h/7 d tappet
784 3 030
RAMSES 784 S 1 year
+10 °C bis +30 °C
0,4–1,2 K
monitoring
2 or 3 conductors 1 two-way switch 1 LED Battery
24 h segments
784 0 801
3 or 4 conductors 1 two-way switch –
24 h tappets
721 0 030
3 or 4 conductors 1 two-way switch 1 LED Heating
24 h/7 d tappet
725 0 030
RAMSES 721
RAMSES 725
–
–
3 days
3 days
–
+10 °C to +30 °C r fixed 1.5 K
–B5Km
–
reduction range
fixed 1.5 K
+10 °C bis +30 °C
1 two-way switch
1 two-way switch
1 two-way switch
1 two-way switch
Wallpaper/ wall cover plate for replacement of RAM 3... devices by new clock thermostats such as RAM 722...
* Terminals 2 and 4 can be bridged if only one 3-wire cable has been laid. In this case the clock mechanism of the thermostat stops when the heating system is switched off in the summer. If more than 3 wires are laid it is possible to provide a separate voltage supply to the clock thermostat from another external wire.
907 0 245
11
all in one RAMSES 800 top2 series
for wall installation
CO2 savings –
Cut heating costs –
Increase living comfort
Digital controllers
RAMSES 832 top2 digital clock thermostat
Plain text operator guidance
on screen
New
Backlit display
Versatile due to
ECO or party programs
Easy plug-in installation
Drill holes suitable for previous RAMSES
800 models
12
Rotary control:
warmer / cooler
Room temperature control with radio control is ideal for retrofitting.
The installation of a radio clock thermostat does not create any disruption. There is no need to lay new cables in the property. The controller can also be sited on a shelf or desk if no suitable location such
as tiles in the bathroom is available. There is now no reason to do
without energy-saving room temperature control.
BELISK
P¡ family
WINDOW CONTACT
P™ SINGLES
P£ SHIFT WORK
P¢ pERM COMFORT
TELEPHONE CONTACT
PRESENCE DETECTOR
FLOOR SENSOR
P∞ PERM REDUCTION
Digital controllers
The new RAMSES generation is elegant, convenient and cost effective.
The "all in one" solution makes it suitable for almost any application.
This makes it the right device for the service vehicle.
OPTIMISATION FUNCTION
HOLIDAY PROGRAM
LOCK KEYPAD
WALL COMPENSATION
ETC
P§ FROST PROTECT
Always have the right program to hand. Or
you can set up the one you need. All preset
programs can be customised - time and temperature.
All in one means:
– A window contact can be connected to an
external input to take account of ventilation
phases
– The heating in a holiday home can be
remotely controlled via a telephone switching input
Achieve additional comfort by:
– Optimisation: It automatically corrects the
heating start up so that the comfort temperature is reached earlier
– Date-controlled holiday program with reduction phase or heating phase for holiday
homes for example
An optional floor sensor for underfloor heating or a remote sensor for publically accessible rooms, for example, can be connected to
an external input.
Designed for controlling circulation pumps,
gas water heaters, burners, heating circuit
distributors with actuators or electrical
underfloor heating.
or Radio
It doesn't matter if it's new build, replacement or upgrading as the 2 or 3 wire connection or radio technology always provide a
solution to satisfy the customer.
13
Wall-mounted
Digital clock thermostat
New
Digital controllers
RAMSES 812 top2 (mains version)
RAMSES 811 top2 (battery version)
6-30 °C
7d 24 h Optimisation Holiday ±1h
auto
STANDARD SERIES
RAMSES 812 top2, mains version
• Digital clock thermostat in elegant, flat, whitedesign
perfectly suits modern decor
• Suitable for energy-saving room temperature controlin
houses, apartments, heating zones,offices, showrooms,
factories, medical practices
• Quick and simple operation using rotary switch for
temperature
• INFO key for viewing important settings
• Easy-to-read text line in the display provides a step-bystep guide to programming
• Optimal adaptation thanks to operating point andswitching differential setting option
• Fast set-up through 3 individually adjustable basic
programs with adjustable comfort, reduction temperatures1st program for families with heating reduction at
night2nd program for singles, heating reduction during
working hours and at night3rd program for shift workers
• 24 programmable switching times with a maximum of 4
temperature levels
• Comfort and reduced temperature adjustable over range
of +10 °C– +30 °C
• Frost protection over range of +6 °C– +10 °C
• Time-limited Party/ECO programs for comfort or reduced
temperature
• Fully automatic summer/winter-time correction
• Power reserve approx. 3 hours in event of loss of
mainssupply
• Child lock or lock for publically-accessible rooms
• Pump protection function in summer months
- 3 or 4-wire connection in base
• Plug-in base for wall or flush-mounted socket installation
RAMSES 811 top2, battery version
• Digital clock thermostat as before except for2 or 3 wire
connection
• Voltage supply from2 x 1.5 V AA batteries
• Bar display for battery capacity with battery replacement
indicator
COMFORT SERIES
RAMSES 832 top2, mains version, as before except for:
• Illuminated display through keystroke
• External input for connection of presence detectors,
remote sensors, floor sensors, window contacts or
telephone remote switches
• Fast start-up thanks to factory preset time and date
• 24 programmable switching times with 3 comfort temperature levels, reduction stage
• Optimisation function for automatic correction of heating
start to enable comfort temperature to be achieved more
quickly
• Holiday program with reduction phase or date-controlled
heating phase for holiday homes, for example
RAMSES 831 top2 (battery version)
RAMSES 832 top2 (mains version)
New
RAMSES 831 top2, battery version
• 2 or 3-wire connection
Type
Features
Operating voltage Temperature
range r/ m/f
Control
Contact
accuracy
Common technical data:
Mode of operation: Type 1 B in accordance with
EN 60730-1
Switch load: Max. 6 (1) A 250 V, min. 1 mA 5 V...
Contact material: AgSnO2
Contact: Two-way switch, floating, electrically isolated
Time accuracy: 1 s/day at 20 °C
Time based on: Quartz
Control accuracy: ≤ ± 0,2 °
Temperature display: accurate to 0.1 °C
Temperature setting range:
+6 °C...+30 °C in 0.2 degree increments
Control type options:
Pulse width modulation or hysteresis controller
Control period: 5…30 mins
Control capture range: ± 0.2 K..5 K
Protection class: II in accordance with EN 60 730-1
Protection rating: IP 20 in accordance with EN 60529
RAMSES 812 top2/ 832 top2
Operating voltage: 230 V, ± 10 %
Frequency: 50 Hz
Power reserve: Approx. 5 hours, permanent heating
operation in the event of power failure
RAMSES 811 top2/ 831 top2
Operating voltage: Battery operation,2 x 1.5 V AA
alkaline batteries
Battery life:
approx. 1 year, depending on switching frequency
Battery replacement time:
Max. 10 min. with no loss of time
Connection examples:
6
8*
7
RAMSES 832 top2 controls circulation pump or actuator
8*
7
T1
T2
L
N
RAMSES 831 top2 controls burners or gas water heaters
* Input for telephone control
Nominal current
at 250 V~
Order no.
RAMSES 812 top2
230 V/50 Hz
24 h/7 d
pure white RAL 9010
Holiday proRAMSES 811 top2
gram
2 x 1.5 V AA
pure white RAL 9010
+10 °C...+30 °C
≤ ± 0,2 K
1 two-way switch
6 (1) A
811 9 132
(Available from Sept. 2009)
+6 °C...+10 °C frost protection
RAMSES 832 top2
24 h/7 d
230 V/50 Hz
Holiday program
pure white RAL 9010
+10 °C...+30 °C
≤ ± 0,2 K
1 two-way switch
6 (1) A
832 0 132
(Available from Sept. 2009)
+6 °C...+10 °C frost protection RAMSES 831 top2
Optimisation
2 x 1.5 V AA
Ext. input
pure white RAL 9010
+10 °C...+30 °C
≤ ± 0,2 K
1 two-way switch
6 (1) A
831 9 132
(Available from Sept. 2009)
+6 °C...+10 °C frost protection
Illuminated display
14
+10 °C...+30 °C
≤ ± 0,2 K
1 two-way switch
6 (1) A
812 0 132
(Available from Sept. 2009)
+6 °C...+10 °C frost protection Wall-mounted
REC 21 receiver (Set S)
Operating voltage: Battery operation,
2 x 1.5 V AA alkaline batteries
Battery life:
approx. 1 year, depending on switching frequency
Battery replacement time:
Max. 10 min. with no loss of time
Transmission frequency: 868 MHz
Transmission power: Less than 10 mW
Emergency function: In the event of power or
transmission failure
Heating mode
Time accuracy: 1 s/day at 20 °C
Time based on: Quartz
Control accuracy: ≤ ± 0,2 °
Temperature display: accurate to 0.1 °C
Temperature setting range:
+6 °C... +30 °C in 0.2 degree increments
Protection class: II in accordance with EN 60 730-1
Protection rating: IP 20 in accordance with
EN 60529
Dimension diagram:
RAMSES 813 top2 HF, Set S, 1 zone control
Consisting of 1 RAMSES 813 top2 HF clock thermostat
and 1 REC 21 receiver as grounding intermediate connector
(16(2) A) e.g. for towel rails or radiators/fan heaters.
New
REC 1 (Set 1)
REC 2 (Set 2)
COMFORT SERIES
RAMSES 833 top2 HF (radio version)
as RAMSES 813 top2 HF, except for the addition of:
• External input for connection of presence detectors,
remote sensors, floor sensors, window contacts or
telephone remote switches
• Fast start-up thanks to factory preset time and date
• Illuminated display through keystroke
• 24 programmable switching times
• Optimisation function
65,5
60
90
RAMSES 833 top2 HF, Set 1, 1 zone control
Consisting of 1 RAMSES 833 top2 HF clock thermostat
and a receiver with a two way switch, 6 (2) A/250 V, for
rail/wall installation (5 temp. levels)
128*
RAMSES 833 top2 HF (radio version)
23
140
125*
55*
RAMSES 833 top2 HF, Set 2, 2 zone control
Consisting of 2 RAMSES 833 top2 HF clock thermostats
and a 2 channel receivers with 2 two way switches, 6 (2)
A/250 V, for rail/wall installation (5 temp. levels)
Clock thermostat
Type
Programs
Temperature
Switching differen-Connection
range r/ m/f tial adjustable
Receiver
Nominal
Contact
Nominal current
voltage
RAMSES 813 top2 HF 24 h/7 days
+6 °C bis +30 °C ± 0.2 K
wireless
Set A
Holiday program Frost protection
230 V
50/60 Hz
1 NO contacts
RAMSES 813 top2 HF 24 h/7 days
+6 °C bis +30 °C ± 0.2 K
wireless
Set S
Holiday program Frost protection
230 V
50/60 Hz
1 NO contacts
RAMSES 833 top2 HF 24 h/7 days
+6 °C bis +30 °C ± 0.2 K
wireless
Set 1
Holiday program Frost protection
230 V
50/60 Hz
1 two-way switch
RAMSES 833 top2 HF 24 h/7 days
+6 °C bis +30 °C ± 0.2 K
wireless
Set 2
Holiday program Frost protection
230 V
50/60 Hz
2 two-way switch
16(2) A/250 V~
Order no.
813 9 503
(Available from Sept. 2009)
16(2) A/230 V~
813 9 505
(Available from Sept. 2009)
6 (1) A
833 9 501
(Available from Sept. 2009)
UHF rod antenna for 868 MHz with wall holder and 2 m screened connection cable (required only for unfavourable reception quality).
Terminal box cover plate for the receiver is included in the scope of supply.
6 (1) A
833 9 502
(Available from Sept. 2009)
907 0 334
15
Digital controllers
REC 11 receiver (Set A)
RAMSES 813 top2 HF, Set A, 1 zone control
Comprising 1 RAMSES 813 top2 HF and an REC 11 receiver with a NO contact, 16 (2) A/250 V, for wall-mounting
Common technical data:
45
New
STANDARD SERIES
RAMSES 813 top2 HF (radio version)
• INFO key for viewing important settings
• Easy-to-read text line in the display provides a step-bystep guide to programming
• Optimal adaptation thanks to operating point andswitching differential setting option
• 24 programmable switching times with a maximum of 4
temperature levels
• Comfort and reduced temperature adjustable over range
of +10 °C– +30 °C
• Frost protection over range of +6 °C– +10 °C
• Time-limited Party/ECO programs for comfort or reduced
temperature
• Fully automatic summer/winter-time correction
• Power reserve approx. 3 hours in event of loss of
mains supply
• Child lock or lock for publically-accessible rooms
• Pump protection function in summer months
- 3 or 4-wire connection in base
• Plug-in base for wall or flush-mounted socket
installation
7d 24 h Holiday ±1h
auto
95
RAMSES 813 top2 HF (radio version)
6-30 °C
80
Digital clock thermostat with radio control
Wall-mounted
Digital clock thermostat
Digital controllers
RAMSES 812 top (mains version)
RAMSES 811 top (battery version)
6-30 °C
RAMSES 812 top, mains version
• Digital clock thermostat in outstanding, flat, functional
design can easily be integrated into any environment
• The external design can be adapted to suit any taste or
fashion through different coloured housing covers
• Suitable for energy-saving room temperature control in
houses, apartments, heating zones, offices, showrooms,
factories, medical practices, holiday homes
• Fast and simple operation of the main day-to-day functions
• INFO key for viewing important settings in plain text
• Text line in the display provides a step-by-step guide to
programming
• The technically experienced user can set various individual control modes
• Optimal adaptation thanks to operating point and
switching differential setting option
• Quick start-up via 2 basic programs with individually
adjustable comfort and reduced temperature
• Individual program with 22 programmable time phases
also enables day-time reduced phases e. g. while out
working
• Comfort and reduced temperature adjustable over
range of +10 °C… +30 °C
• Frost protection option over range of +6 °C… +10 °C
• Party / ECO program with adjustable duration for comfort and reduced temperature without having to modify
standard program
• Fully automatic summer/winter-time correction
• Power reserve approx. 5 hours in event of loss of mains
supply
• Holiday program with reduced temperature or datecontrolled heating phase, e.g. for holiday homes
• 3 or 4-wire connection in base
• Plug-in base for wall or flush-mounted socket installation
7d 24 h Holiday ±1h
auto
Technical data:
Switch load: Max. 6 (1) A 250 V~, at least. 1 mA 5 V
Contact material: AgSnO
Time accuracy: 1 s/day at 20 °C
Time based on: Quartz
Control accuracy: ≤ ± 0,2 K
Temperature display: accurate to 0.1 °C
Temperature setting range: +6 °C... +30 °C in 0.2
degree increments
Control type options: Pulse width modulation or
hysteresis controller
Control period: 5…30 mins
Control capture range: ± 0.2 K…5 K
Protection class: II in accordance with EN 60 730-1
Protection rating: IP 20 in accordance with EN 60529
2
RAMSES 812 top
Operating voltage: 230 V, ± 10 %
Frequency: 50 Hz
Power reserve:Approx. 5 hours, permanent heating
operation in the event of power failure
Contact: Two-way switch, floating, not for SELV
RAMSES 811 top
Operating voltage: Battery operation,2 x 1.5 V AA
alkaline batteries
Battery life: Approx. 1 year, depending on switching
frequency
Battery replacement time: Max. 10 min. with no loss
of time
Contact: Two-way switch, floating, suitable for SELV
RAMSES 811 top, battery version
• Digital clock thermostat as before but with 2 or 3-wire
connection, voltage supplied through 2 x 1.5 V AA
batteries
• Battery monitoring with battery replacement indicator
Individual room control
Combining the aforementioned clock
thermostats with Theben actuators
enables convenient, needs-driven
individual room control. The actuators are
simply screwed onto the individual radiators
or into the heating circuit distributor in underfloor
heating systems.
See page 39 for a detailed description.
Type
Program
Operating voltage Temperature
ranger/ m/f
Control
Contact
accuracy
Nominal current
at 250 V~
Order no.
RAMSES 812 top pure white RAL 9010
24 h/7 d 230 V/50 Hz
Holiday program
+10 °C...+30 °C
≤ ± 0,2 K
1 two-way switch
6 (1) A
812 0 032
+6 °C...+10 °C frost protection RAMSES 811 top pure white RAL 9010
24 h/7 d 2 x 1.5 V AA
Holiday program
+10 °C...+30 °C
≤ ± 0,2 K
1 two-way switch
6 (1) A
811 9 032
+6 °C...+10 °C frost protection
16
Wall-mounted
RAMSES 832 top (mains version)
RAMSES 831 top (battery version)
6-30 °C
RAMSES 832 top, mains version
• Suitable for energy-saving room temperature control in
houses, apartments, heating zones, offices, showrooms,
factories, medical practices, holiday homes
• Ideal device for shift workers as 3 different weekly
programs can be set for early and late shifts as well as
days off work. One of the 3 programs can be selected as
required simply by using the rotary switch
• Fast and simple operation of the main day-to-day
functions
• INFO key for viewing important settings in plain text
• Text line in the display provides a step-by-step guide to
programming
• The technically experienced user can set various individual control modes
• Optimal adaptation thanks to operating point and
switching differential setting option
• Quick start-up via 2 basic programs. Comfort and reduction phase times can be individually amended. 3 comfort
and 2 reduced temperatures can be allocated to each
phase.
• Individual program with 32 programmable time phases
also enables day-time reduced phases e. g. while out
working
• Comfort and reduced temperature adjustable over range
of +6 °C… +30 °C
• Optimisation function for automatic correction of heating start to enable comfort temperature to be achieved
more quickly
• Frost protection option over range of +6 °C… +10 °C
• Party / ECO program with adjustable duration for comfort and reduced temperature without having to modify
standard program
• Fully automatic summer/winter-time correction
• Power reserve approx. 5 hours in event of loss of mains
supply
• Holiday program with reduced temperature or datecontrolled heating phase, e. g. for holiday homes
• T emperature shock recognition saves heating costs during
short ventilation phases. (function can be switched off)
• Pump protection function prevents the circulation pumps
sticking outside the heating periods through regular
short operation. (function can be switched off)
• Elapsed-time counters for recording relay switching
times e. g. burner running time.
• 3 or 4-wire connection in base
• Plug-in base for wall or flush-mounted socket installation
RAMSES 831 top, battery version
• Digital clock thermostat as before but with 2 or 3-wire
connection, voltage supplied through 2 x 1.5 V AA
batteries
• Battery monitoring with battery replacement indicator
Type
Program
Operating voltage Temperature
range r/ m/f
7d 24 h Optimisation ±1h
auto
Technical data:
Switch load: Max. 6 (1) A 250 V~, at least. 1 mA 5 V
Contact material: AgSnO
Time accuracy: 1 s/day at 20 °C
Time based on:Quartz
Control accuracy: ≤ ± 0,2 K
Temperature display: accurate to 0.1 °C
Temperature setting range: +6 °C... +30 °C in
0.2 degree increments
Control type options: Pulse width modulation or
hysteresis controller
Control period: 5…30 mins
Control capture range: ± 0.2 K…5 K
Protection class: II in accordance with EN 60 730-1
Protection rating: IP 20 in accordance with EN 60529
2
RAMSES 832 top:
Operating voltage: 230 V, ± 10 %
Frequency: 50 Hz
Power reserve: approx. 5 hours
Contact: Two-way switch, floating, not for SELV
Digital controllers
Digital clock thermostat with optimisation function
RAMSES 831 top:
Operating voltage: Battery operation,2 x 1.5 V AA
alkaline batteries
Battery life: Approx. 1 year, depending on switching
frequency
Battery replacement time: Max. 10 min. with no loss
of time
Contact: Two-way switch, floating, suitable for SELV
Individual room control
Combining the aforementioned clock
thermostats with Theben actuators
enables convenient, needs-driven
individual room control. The actuators are
simply screwed onto the individual radiators
or into the heating circuit distributor in underfloor
heating systems.
See page 39 for a detailed description.
Control
Contact
accuracy
Nominal current
at 250 V~
Order no.
RAMSES 832 top pure white RAL 9010
24 h/7 d 230 V/50 Hz
Holiday program
+10 °C...+30 °C
≤ ± 0,2 K
1 two-way switch 6 (1) A
832 0 032
+6 °C...+10 °C frost protection RAMSES 831 top pure white RAL 9010
24 h/7 d 2 x 1.5 V AA
Holiday program
+10 °C...+30 °C
≤ ± 0,2 K
1 two-way switch 6 (1) A
831 9 032
+6 °C...+10 °C frost protection
17
Wall-mounted
Digital clock thermostat for electric underfloor heatingwith fast
heating function and elapsed hours counter
RAMSES 818 top 6/16 A
• Clock
thermostat for underfloor heating, designed for
energy saving control of:
– electrical underfloor heating
– fast reacting underfloor heating systems
– Quick heating for 1 h by holding down info key
• Operating hours counter for recording power on time
• The controllers are equipped with selectable temperature limits 40 °C (tiles) or 30 °C (laminates, wood, cork)
• 3 different weekly programs available via rotary switch
• Ideal
device for shift workers as 3 different weekly programs can be set for early and late shifts as well as days
off work.
• Quick
start up and easy use for day-to-day functions via
2 basic programs
• 3 comfort and 2 reduced temperatures can be allocated
to the 32 programmable time phases
• Info
key for viewing important settings
• Text
line in the display provides a step-by-step guide to
programming
• Different
control types can be individually set
• Optimal
adaptation thanks to operating point and
switching differential setting option
• Comfort
and reduction phase of +6 °C to +30 °C available allowing a pleasant floor surface temperature to be
achieved
• Optimisation
function for automatic correction of heating
start up
• Frost
protection option over range of +6 °C… +10 °C
• Party/
ECO program with adjustable period for comfort
or reduced temperature
• Power
reserve approx. 3 hours in event of loss of mains
supply
• Easy
installation via plug-in base for flush-mounted
socket
• Specially
encapsulated temperature sensor (IP 65)
with 4 m connecting cable fir installation in empty pipes
Digital controllers
RAMSES 818 top
6-30 °C
7d 24 h ±1h
Holiday
auto
Technical data:
Operating voltage: 230 V–240 V, ± 10 %
Nominal frequency: 50-60 Hz
Power reserve: 3 hours
Time accuracy: ±1 s/d at 20 °C
Contact: Changeover switch, floatingmax. 6 A/250 V~,
min.1 mA/5 V
Control accuracy: ± 0.2 K
Temperature display: accurate to 0.1 °C
Temperature measuring range: 0 °C...+50 °C
Temperature setting range: +6 °C...+30 °C (+40 °C)
in 0.2 degree increments
Control period: 5...30 min (PD controller)
Control capture range: ±0.2 K…±5 K (PD controller)
Switching hysteresis: ±0.2 K…±1.0 K (hysteresis
controller)
Memory locations: 32 temperature changes, programmable for Mon–Fri, Sat–Sun, every day or individual days
Protection class: ll in accordance with EN 60 730-1
subject to designated installation
Protection rating: IP 21 in accordance with EN 60 529
RAMSES 818 top 16 A
Contact: NO contact, max. 16 A/250 V~
Protection class: ll in accordance with EN 60 730-1 subject to designated installation in a flush-mounted socket
Basic program:
Program 1:
Mon–Fri
Comfort 5.30– 9.00 and 21.00–23.00
Sat/Sun
Comfort 7.30–10.30 and 21.00–23.00
Program 2:
Mon–Fri
Sat/Sun
Comfort 6.00– 8.00 and 16.00-22.00
Comfort 6.00– 8.00 and 16.00-23.00
Program 3:
freely programmable
Elektroheizung
2
2
RAMSES 818 top
230 V~
Electric under-floor heating
Dimensional diagrams
145
3
4
5
6
32
7
6
2
4000
98.3
1
32.2
Type
Program
18
Nominal
voltage
Temperature
Connection
Contact
range r/ m/f
Nominal current
at 250 V~
Order no.
RAMSES 818 top
6 A
24 h/7 days 230 V/50 Hz
Holiday program
+6 °C...+30 °C (+40 °C)
+6 °C...+10 °C frost protection
3 or 4 way conductors
+ 2 wire sensor
1 two-way switch
6 (1) A
818 0 035
RAMSES 818 top 16 A
24 h/7 days 230 V/50 Hz
Holiday program
+6 °C...+30 °C (+40 °C)
+6 °C...+10 °C frost protection
3 or 4 way conductors
+ 2 wire sensor
1 NO contacts 16 (2) A
818 0 036
Wall-mounted
6-30 °C
Function:
Clock thermostat as RAMSES 812 top except for additional
modem interface for remote adjustment of set temperatures via phone or SMS. Switchable for 2 or 3-point control
or 2-stage control with sequence-controlled contact.
RAMSES 816 top
• Clock thermostat for universal application
• Simple retrofitting through 2-wire Open Therm connection
in living space, no battery operation
• Option for remote control of set temperature via telephone or SMS with additional voice modem or GSM
modem
• Switchable for on/off or 3-point control with 8 A/250 V~
switching outputs
• Second switching step controllable by adjustable
switching differential temperature
• Suitable for 2-phase burners, blowers, convectors,
additional heaters for under-floor heating etc.
• An additional feed sensor is required for mixer control
• 2-wire BUS connection from room thermostat to control
unit with power pack and 2 output relays
• Both devices with plug-in base and large terminal area
• Simple connection through short-circuit proof and
non-reversible 2-wire BUS (protection class III)
RAMSES 816 top OT
7d 24 h ±1h
Holiday
auto
Technical data:
Operating voltage: 230 V~, +10 %/-15 %
Nominal frequency: 50-60 Hz
Power reserve: approx. 4 hrs. after 3 days charging time
Switch load: max. 8 (1) A/250 V
Contact material: AgNi
Contact: 1 two way switch and 1 NO contact, floating,
not for SELV
Time based on: Quartz
Control accuracy: ± 0.2 K
Temperature display: accurate to 0.1 °C
Temperature measuring range: 0 °C... +50 °C
Temperature setting range: +10 °C... +30 °C in 0.2
degree increments +6 °C... +10 °C frost protection
Memory locations: 32 freely programmable memory
locations with free weekday block formation
Protection class: ll in accordance with EN 60730-1
subject to designated installation
Protection rating: IP 20 in accordance with EN 60529
Digital controllers
Open Therm digital clock thermostat for
2 or 3-point control
OT-Box RAMSES 816 top
Accessories:
MODEM
RAMSES 816 top
2-wire OT BUS
RS 232
3 point
control
Feed temperature sensor
for mixer control urgently required
Heating
stage II
ϑ
2
M
OT box
2
230 V~
2/3
Connection diagrams see page 28.
2
Dimensional diagrams
145
2
3
4
5
6
7
98.3
1
32.2
GSM modem
Type
Program
Operating voltage Temperature
range r/ m/ f
Temperature differential
for sequence-controlled Connection
contact
RAMSES 816 top 24 h/7 days 230 V/50 Hz
+6 °C bis +30 °C
0.5 to 2.5 K
2 wires
Holiday program
Contact
Control unit
Nominal current
at 250 V~
Order no.
1 NO contacts
1 two-way switch
8 (1) A
816 9 032
Feed temperature sensor for mixer control with RAM 816 / 817 top required
GSM modem incl. antenna, power unit and connecting cables
907 0 371
907 0 396
19
Wall-mounted
Open Therm digital clock thermostat with
weather compensation remote sensor
6-30 °C
RAMSES 817 top
As RAMSES 816 top, with separate temperature weather
compensation sensor for wall mounting (included in set)
• Also suitable for temperature control in dusty or humid
rooms
• External temperature sensor in wall-mounted housing
with protection rating to IP 65 and protection class III,
cable length 4 m
• RAMSES 382 FA sensor can be connected to OT-Box as
an option
• Maximum sensor cable length 50 m, Ø > 0.75 mm2
• Both devices with plug-in base and large terminal area
• Simple connection through short-circuit proof and nonreversible 2-wire BUS (protection class III)
• An additional feed sensor is required for mixer control
Digital controllers
RAMSES 817 top OT
OT-Box RAMSES 817 top
7d 24 h ±1h
Holiday
auto
Technical data:
Operating voltage: 230 V~, +10 %/-15 %
Nominal frequency: 50-60 Hz
Power reserve: approx. 4 hrs. after 3 days charging time
Switch load: max. 8 (1) A, 250 V~
Contact material: AgNi
Contact: 1 NO contact and 1 two way switch, floating,
not for SELV
Time based on: Quartz
Control accuracy: ≤ ± 0,2 K
Temperature display: accurate to 0.1 °C
Temperature measuring range: 0 °C... +50 °C
Temperature setting range: +10 °C... +30 °C in 0.2
degree increments +6 °C... +10 °C frost protection
Memory locations: 32 freely programmable memory
locations with free weekday block formation
Protection class: ll in accordance with EN 60 730-1
subject to designated installation
Protection rating: IP 20 in accordance with EN 60529
Temperature sensor: IP 65 in accordance with EN
60529
External temperature sensor IP 65
Accessories:
Sensor connection on room thermostat also possible
2
MODEM
2
RAMSES 817 top
2-wire OT BUS
External temperature sensor IP 65
Feed temperature sensor
for mixer control urgently required
RS 232
3 point
control
Heating
stage II
ϑ
2
OT box
2
230 V~
M
Connection diagrams see page 28.
2/3
2
Dimension diagrams
145
3
4
5
6
7
c 67
2
98.3
1
32.2
c 74
5
GSM modem
23.3
Type
Program
Operating voltage Temperature
range r/ m/ f
Temperature differential
for sequence-controlled Connection
contact
RAMSES 817 top 24 h/7 days 230 V/50 Hz
+6 °C bis +30 °C
0.5 to 2.5 K
2 wires
Holiday program
Contact
Control unit
Nominal current
at 250 V~
Order no.
1 NO contacts
1 two-way switch
8 (1) A
817 9 032
Feed temperature sensor for mixer control with RAM 816 / 817 top required
GSM modem incl. antenna, power unit and connecting cables
20
907 0 371
907 0 396
Wall-mounted
5–39 °C
Function:
Theben offers an innovative system for room temperature
control in combination with under-floor and radiator heating. Cost-efficient and convenient retrofitting for all systems
through radio-control This creates new retrofitting opportunities, not only in new-build but predominantly in occupied
flats, apartments and functional buildings. Each system
comprises a clock thermostat per room with integrated radio
transmitter and a receiver. For control over several rooms,
several sets can be operated in parallel
• RAMSES 813 top HF, the new radio system enables
optimal energy saving while ensuring a comfortable
environment
• The sets can be upgraded with further modules for operation over several heating zones without mutual interference
• Operation is especially simple thanks to step-by-step user
guidance through text lines in the display
• A rotary switch can be set to one of 3 different programs
(2 pre-programmed basic and one customised program with
a max. of 22 temperature phases
• Further comfort functions include party and ECO
programs, date-controlled holiday program and
automatic summer/wintertime changeover.
• The
highly-modern radio system is digitally-coded and
protected against interference from other radio systems
• The control unit reliably receives the radio signals of the
battery-powered room transmitter in the building through
walls and ceilings
• High interference immunity through repeated transmission of coded ON/OFF signals for each channel,
ensuring zero failure even in large buildings with individual
room controls
• Level display with 5 LEDs for checking reception quality
and detecting interference fields at the installation location
• Extremely reliable thanks to battery monitoring and
battery replacement indicator
• Simple
battery replacement without loss of time of program
• Emergency receiver function, in the event of transmitter
failing or radio receiver being defective over a prolonged
period
RAMSES 813 top HF (radio)
REC 11 receiver (set A)
7d 24 h ±1h
Holiday
auto
Technical data:
Control accuracy: ± 0.2 K
Control period: 5...30 min
Transmission frequency: 868 MHz
Transmission power: < 10 mW
Transmission frequency and transmission power
do not need to be registered in Germany.
Power supply: 2 x 1.5 V AA alkaline batteries
Battery life: approx. 2 years, depending on switching
frequency
Range: Approx. 25-30 m in buildings, depending on type
REC 11/21 receiver
Operating voltage: 230 V, ±10 %, 50/60 Hz
Switching capacity:
16 (2) A/250 V~ (Set A) floating, not for SELV
16 (2) A/230 V~ (Set S) not floating
Coding: 65536 Codes
Field strength display: 5 LEDs
Relay status display: 1 LED
Protection class: ll in accordance with EN 60730-1
subject to designated installation
Protection rating: IP 20 in accordance with EN 60529
Digital controllers
Digital clock thermostat with radio control
RAMSES 813 top HF, Set A, 1 zone controller
• Consisting of 1 RAMSES 813 top2 HF clock thermostat
and an REC 11 receiver with a NO contact 16 (2) A/
250 V~, for wall-mounting
REC 21 receiver grounding
intermediate connector (Set S)
RAMSES 813 top HF, Set S, 1 zone controller
• Consisting of a RAM 813 top HF clock thermostat and
a REC 21 receiver as grounding intermediate connector
(16 (2) A) e. g. for heated towel rail or fan heater
Dimensional diagrams
Individual room control
145
2
3
4
5
6
Combining the aforementioned clock
thermostats with Theben actuators
enables convenient, needs-driven
individual room control. The actuators are
simply screwed onto the individual radiators
or into the heating circuit distributor in underfloor
heating systems.
See page 39 for a detailed description.
7
98.3
1
32.2
Clock thermostat
Receiver
Type
Programs
Temperature
Switching differential
Connection
range r/ m/f adjustable
Nominal
Contact
Nominal current
voltage
Order no.
RAMSES 813 top HF
Set A
24 h/7 days
Holiday program
+6 °C - 30 °C
± 0.2 K
wireless
Frost protection
230 V
50/60 Hz
1 NO contacts
16(2) A/250 V~
813 9 403
RAMSES 813 top HF
Set S
24 h/7 days
Holiday program
+6 °C bis 30 °C ± 0.2 K
wireless
Frost protection
230 V
50/60 Hz
1 NO contacts
16(2) A/230 V~
813 9 405
21
Wall-mounted
Digital clock thermostat with radio control
6-30 °C
Function:
Theben offers an innovative system for room temperature
control in combination with under-floor and radiator heating. Cost-efficient and convenient retrofitting for all systems
through radio-controlled communication. This creates completely new opportunities, not only in new-build properties but
predominantly in occupied flats, apartments and functional
buildings. Each system comprises a clock thermostat per room
with integrated radio transmitter and a receiver. For control
over several rooms, several sets can be operated in parallel
Digital controllers
RAMSES 813 top HF (radio)
REC 1 (1 channel receiver, 868 MHz)
• RAMSES 813 top HF, the new radio system enables
optimal energy saving while ensuring a comfortable
environment
• The sets for 1/2 heating zones can be upgraded with further
modules for operation over several heating zones without
mutual interference
• Operation is especially simple thanks to step-by-step
user guidance via on screen texts
• A rotary switch can be set at any time to one of 3 programs (2 pre-programmed basic and one individualised
program with a max. of 22 temperature phases)
• Further comfort functions include party and ECO
programs, date-controlled holiday program and
automatic summer/wintertime changeover
• The radio system is digitally-coded and protected against
interference from other radio systems
• The central control unit reliably receives the radio signals
of the battery-powered room transmitter in the building
through walls and ceilings
• High interference immunity through repeated transmission
of coded ON and OFF signals for each channel, ensuring
zero failure even in large buildings with individual room
control
• Level display with 5 LEDs for checking reception quality and
detecting interference fields at the installation location
• Projection antenna for optimising reception quality
• High reliability through battery monitoring
• Simple battery replacement without loss of time or program
• Control
device with floating two way switch 6 (1) A/250 V~
• Emergency
receiver function, in the event of transmitter
failing or radio receiver being defective over a prolonged
period
7d 24 h ±1h
Holiday
auto
Technical data:
Control accuracy: < ± 0.2 K
Control period: 5...30 min
Transmission frequency: 868 MHz
Transmission power: < 10 mW
Power supply: 2 x 1.5 V AA alkaline batteries
Battery life: approx. 2 years, depending on switching
frequency
Range: Approx. 20–30 m in buildings depending on type
If the standard projection antenna is insufficient due to
unfavourable reception, a rod antenna can be used to
improve reception quality
REC receiver
Operating voltage: 230 V~, +10 %/–15 %, 50–60 Hz
Switching capacity: 6 (1) A/250 V~, floating, not for
SELV
Antenna system: Projection antenna
Field strength display: 5 LEDs
Relay status display: 1 LED per channel
Protection class: ll in accordance with EN 60730-1
subject to designated installation
Protection rating: IP 20 in accordance with EN 60529
RAMSES 813 top HF, Set 1, 1 zone controller
• Consisting of RAM 813 top HF clock thermostat and a
receiver with a two way switch 6 (1) A/250 V~ and wall
installation set
RAMSES 813 top HF, Set 2, 2 zone controller
• Consisting of two RAM 813 top HF clock thermostat and
a 2-channel receiver with 2 two way switches 6 (1) A/
250 V~ and wall installation set
REC 2 (2 channel receiver, 868 MHz)
RAMSES 813 top HF, Set 4, 4 zone controller
• Consisting of four RAM 813 top HF clock thermostats and
two 2 channel receivers with 4 two way switches
Dimensional diagrams
Individual room control
145
5
6
7
125*
22
45
4
80
3
65,5
60
90
128*
2
98.3
1
32.2
55*
Combining the aforementioned clock
thermostats with Theben actuators
enables convenient, needs-driven
individual room control. The actuators are
simply screwed onto the individual radiators
or into the heating circuit distributor in underfloor
heating systems.
See page 39 for a detailed description.
Wall-mounted
Digital clock thermostat with radio control
6-30 °C
RAM 813 top HF
RAM 813 top HF
REC
C1
M
1 2 3
4 5 6
RAM 813 top HF
C1
C1
REC
7d 24 h ±1h
Holiday
auto
7 8
C1
1 2 3
L N
C2
C2
4 5 6
M
7 8
L N
L
N
L
N
RAMSES 813 top HF, Set 1, REC receiver
REC receiver controls thermal actuator for hot water heating or radiator valve and/or recirculation pump or electric
heating
RAMSES 813 top HF, Set 2, REC receiver
REC receiver controls e. g. two heating circuits with
actuator for hot water heating or radiator valve and/or
recirculation pump or electric heating
Radio pilot room controller e.g. for 2 flats (2 zone
control)
➊ RAM 813 top HF clock thermostat per flat with transmitter in the most-used room (pilot room), no connection wires required.
➋ Receiver with 2 channels controls the heat supply to
the two flats via the respective recirculation pump.
Digital controllers
➊
Flat 1
➊
Flat 2
➋
e.g. bathroom
Individual radio room control for 2 and more
rooms with under-floor heating
➊ RAM 813 top HF clock thermostat with transmitter in each living room or office.
➋ Receiver in heating circuit distributor switches the Theben actuator drives that control the heat supply to the individual heating circuits.
➌ Actuators can be attached to available valves in the heating circuit distributor.
e. g. living room
➊
➊
➋
➌
Type
Clock thermostat
Receiver
Programs
Temperature
Switching differential Connection
range r/ m/f
Nominal
Contact
voltage
Nominal current
at 250 V~
Order no.
RAMSES 813 top HF
Set 1
24 h/7 days
Holiday program
+6 °C - 30 °C
± 0.2 K
wireless
Frost protection
230 V
50/60 Hz
1 two-way switch
6 (1) A
813 9 401
RAMSES 813 top HF
Set 2
24 h/7 days
Holiday program
+6 °C - 30 °C
± 0.2 K
wireless
Frost protection
230 V
50/60 Hz
2 two-way switch
6 (1) A
813 9 402
RAMSES 813 top HF
Set 4
24 h/7 days
Holiday program
+6 °C - 30 °C
± 0.2 K
wireless
Frost protection
230 V
50/60 Hz
4 two-way switch
6 (1) A
813 9 404
UHF rod antenna for 868 MHz with wall holder and 2 m screened connection cable (required only for unfavourable reception quality).
Terminal box cover plate for the receiver is included in the scope of supply.
907 0 334
23
Wall-mounted
Open Therm heating controller for on/off or 3-point control, weather-dependent, service water and circulation
control
Digital controllers
RAMSES 855 top2 OT
New
RAMSES 855 top
Installation in living areas or in boiler rooms
OT-Box RAMSES 855 top
Installation in boiler room
6-30 °C
RAMSES 855 top / RAMSES 855 top2 OTUniversal
digital heating controller with 4-channel digital control,
complete room operation and monitoring. Additional
modem interface (RS 232) for remote temperature setting
by phone or SMS. Extremely simple operation through text
guidance display and pre-configured programs for families
and working people. Fast installation through 2-wire
control device to controller connection in the boiler room.
• Boiler/feed temperature (control circuit 1) controlled by
switching the burner
• Feed temperature (control circuit 2) controlled via pump
or mechanically-adjustable mixer
• 3-point controller with feed sensor
• Mixer control with feed temperature limit
• Hot water controlled by switching load pump
• Highly economical control of hot water circulation pump,
as time and temperature dependent
• Simple to operate via selector switch for 8 different
connection /function types.
• Automatic sensor recognition for weather or room
dependent control; can be switched manually at any time
• Simple selection of 3 switching programs. An individual
weekly program, e.g. for shift workers, 2 pre-configured
programs for families and working people (855 top2).
• Choice of 3 permanent programs: Comfort, reduced,
frost-protection
• Info button for viewing key data such as date, time,
program and set point/actual temperature and ambient
temperature. Displays the switching status of the outputs.
• RS 232 interface for: – GSM modem set point temperature setting via SMS
• Additional switching program for service water utilisation
times
• Adjustable service water storage temperature,additional
legionella protection can be configured through shortterm interval based feed heating
• Party/Eco program with adjustable period for comfort
or reduced temperature
• Date-controlled holiday program
• Automatic summer/winter time switchover
• Pump block protection
OT Center
• extends the RAMSES 855 top with– an additional mixer
circuit– chimney sweep function– a relay output for error
messages
OT Center
Installation in boiler room
7d 24 h ±1h
Holiday
7d
auto
Technical data:
Operating voltage: 230 V~, +10 %/–15 %
Nominal frequency: 50-60 Hz
Power reserve: Approx. 3 hours after 3 days charging
time
Memory locations: 32
Switch load: 8 (1) A, 250 V~
Contact material: AgNi
Contacts: floating, not for SELV
Switching hysteresis: 2-20 K
Mixer runtime: 2-10 min
Heating curves: infinite, individual adjustment for
radiator and under-floor heating through low end and
final point adjustment
Adjustment ranges for room-dependent control:
– Comfort temperature: +15 °C... +30 °C
– Reduced temperature: +10 °C... +29,8 °C
– Frost protection: +6 °C... +15 °C
Protection class: ll in accordance with EN 60 730-1
subject to designated installation
Protection rating: IP 20 in accordance with EN 60529
RAMSES 855 topinputs:
• External sensor (contained in set)
• Heating circuit feed sensor(contained in set)
• Feed or plunge sensor for service water
• Feed sensor for circulation
Outputs:
• 4 NO contacts
OT Centerinputs:
• Feed sensor (included in the scope of supply)
• “Chimney sweep” switch
Outputs:
• 3 NO contacts 5 (1) A, 250 V~
• 1 two way switch 5 (1) A, 250 V~
Accessories:
External temperature Feed temperature sensor
sensor
for mixer control urgently
required
Dimension diagram
145
2
3
4
5
6
7
98.3
1
32.2
GSM modem
Type
Program
Operating voltage
Temperature
range r/m/f
Adjustable feed
temperature limit
Connection
Contact
Control unit
Nominal current
at 250 V
Order no.
RAMSES 855 top2 OT 24 h/7 days incl. OT box
Holiday prog.
230 V/50 Hz
+6 °C bis +30 °C
+40 °C - +90 °C
2 wires
8 (1) A
855 9 132
RAMSES 855 top incl. OT box
24 h/7 days Holiday prog.
230 V/50 Hz
+6 °C bis +30 °C
OT Center 230 V/50 Hz
+6 °C bis +30 °C
+30 °C to +75 °C
4 NO contacts
(Available from Sept. 2009)
+40 °C - +90 °C
2 wires
4 NO contacts
3 NO contacts, 1 two way switch
8 (1) A
855 9 032
5 (1) A
907 0 427
855 9 901
907 0 371
907 0 379
907 0 396
Set RAMSES 855 top + OT Center
Feed temperature sensor additionally required for applications with 2 feed sensors
Plunge sensor (Ø 6 mm) additionally required for applications with service water control or boiler plunge sensor
GSM modem incl. antenna, power unit and connecting cables
24
Wall-mounted
Open Therm heating controller for on/off
or 3-point control, weather-dependent,
service water and circulation control
6-30 °C
7d 24 h ±1h
Holiday
auto
The RAM 855 provides the following types of control:
ϑ
1.) Weather-dependent heating control with outside temperature sensor. The control device can be installed in the living
room or heating room. The OT Box with power unit and relay is
installed in the heating room.
2
2
2.) Room-temperature driven control without outside temperature sensor. A room temperature sensor is built into the
operating device so that sunlight, fireplaces and other heat
sources can be taken into account. An additional voice modem
in the room-dependent controller makes it possible to set the
remote temperature over thetelephone.
OT-Box
Connection diagram 1
Heating control via circulation pump with boiler control
OT-Box
1
7
2 3 4 5 6
M
OT-Box
RAMSES 855
12 13 14 15 16 17 18 19
10 11
Feed temperature control via burner control
Feed temperature control via burner control with service
water and circulation control (connection diagram 1)
8 9
AF
BWT
BWRF
L
N
AF
BWF
KF/VLF
BWRF
Heating control via a motor-driven mixer
=
=
=
=
LP
ZP
HP
KF/VLF
Outside temperature sensor
Household water temperature sensor
Boiler/Forward flow temperature sensor
Household water return flow sensor
LP = Loading pump household water
HP = Heating pump
ZP = Circulation pump
RAMSES 855 top / RAMSES 855 top2 OT
weather or room-dependent heating controller,
mixer control and service water temperature control
OT-Box
OT-Box
Connection diagram 2
M
M
M Mixer
OTBUS
1
Feed temperature control via mixer control
Feed temperature control via mixer control with service
water control (connection diagram 2)
7
2 3 4 5 6
M
OT-Box
RAMSES 855
ϑ
8 9
12 13 14 15 16 17 18 19
10 11
ϑ
ϑ
BWT
OT-Box
Feed temperature control via mixer and burner control
open
ϑ
AF
M
closed
L
N
LP
HP
VLF
AF = Outside temperature sensor
BWF = Household water temperature sensor
VLF = Forward flow temperature sensor
LP = Loading pump household water
HP = Heating pump
RAMSES 855 top / RAMSES 855 top2 OT
weather or room-dependent heating controller,
mixer control and service water temperature control
Connection diagram 3
230 V~
L1
N
1
2
3
4
5
6
7
12
13
14
15
16
potential-free contact
“Error“
8
9
18
19
OT Center
11
10
ϑ
17
OT box
4,7 k “Chimney sweep” connection
NTC
switch
see above
off
on
Heating circuit pump
Mixer
RAMSES 855 top / RAMSES 855 top2 OT + OT Center
Mixer circuit upgrade via OT center
25
Digital controllers
OTBUS
OT-Box
Distributor installation
Zone control (6 TE)
7d 24 h ±1h
Holiday
auto
Function
Clock thermostat for distributor installation for remote
temperature control. Protected against unauthorised
adjustment, therefore suitable for offices, practices, retail
premises, schools and meeting rooms.
RAMSES 366/1 top, 1 zone
• Clock thermostat with daily/weekly/holiday programs
for setting comfort/reduced temperature phases
• Daytime temperature range +6 °C... +30 °C and
night-time temperature range of +6 °C... +26 °C
• Daily/weekly program can be set to the minute
• 42 memory locations, date-controlled holiday program
• Operator guidance through integrated text line on the
LCD screen (see page 25)
• Programming displayed graphically by a bar arrangement in the LCD display
• Automatic summer/winter-time correction, can be
disabled or programmed as required (CET, GB, USA
changeover rule also available)
• Guided copying of switching times to other weekdays
(free block formation)
• 10 year power reserve
• Manual switching pre-selection and operating mode
selector switch for: Automatic mode, comfort mode,
reduction mode, frost protection mode
• Connection for telephone remote control for switching
to comfort mode or frost protection mode over the
telephone
• LED display of active operating status as well as relay
status
• Remote temperature sensor required, see accessories
• Two-way switch, floating 10 (2) A/250 V~, not for SELV
• Terminal cover for wall installation, sealable no. 907
0 053
• Control panel installation with assembly kit no.
907 0 001
• Program storage via EEPROM
• PIN code
Digital controllers
RAMSES 366/1 top
RAMSES 366/2 top
RAMSES 366/1 top
ϑ
L
N
M
1 2 3
4 5 6
7 8 9
ϑ
*
L N
**
RAMSES 366/2 top
ϑ
L
N
1 2 3
ϑ
4 5 6
M
7 8 9 10 11 12 13 14
ϑ
ϑ
L N
*
*
*Control of circulation pump, electronic actuator, thermal mixer valve or oil/gas burner
**
RAMSES 366/2 top, 2 zones
• Clock thermostat as above but for 2 zones with
different temperature phases
• 42 memory locations
• 2 remote temperature sensors required, see accessories
• 2 x two-way switches, floating 10 (2) A/250 V~, not
for SELV
Dimension diagrams for RAMSES 366 top + remote sensor
Terminal box cover plate
%
Common technical data:
Operating voltage: 230 V~, +10 % /–15 %
Frequency: 50–60 Hz
Power consumption: max. 3 VA
Time based on: Quartz
Time accuracy: ≤ ±1 s/day at 20 °C
Shortest switching time: 1 min
Power reserve: 10 years using lithium battery (20 °C)
Connection voltage at sensor: SELV
Contact: opening width less than 3 mm (µ), floating, not
for SELV
Contact material: AgCdO
Permissible ambient temperature: -10 °C... +50 °C
Housing and insulation material: High-temperature
resistant, self-extinguishing thermoplastic
Max. connection cross-section: 4 mm2
Protection class: II in accordance with EN 60 730-1
with designated installation protection class III for remote
sensors 1 and 2
Protection rating: IP 20 in accordance with EN 60 529
Accessories:
Remote sensor 1
Remote sensor 2 with temperature adjustment ± 3 K
**Connection for
separate telephone
remote switch
TF
Individual room control
Combining the aforementioned clock
thermostats with Theben actuators
enables convenient, needs-driven
individual room control. The actuators are
simply screwed onto the individual radiators
or into the heating circuit distributor in underfloor
heating systems.
See page 39 for a detailed description.
*with terminal box cover plate
Model
Program
Power reserve approx. Temperature
range r/ m
Switching
Special function
Contact
differential
Nominal current Order no.
at 250 V~
RAMSES 366/1 top
24 h/7 days
10 years
Holiday program
+6 °C bis +30 °C
≤ 0.5 K
+6 °C to +26 °C
Connection for 1 two-way switch
Telephone remote switch
10 A
366 0 002
RAMSES 366/2 top
24 h/7 days
10 years
Holiday program
+6 °C bis +30 °C
≤ 0.5 K
+6 °C to +26 °C
Connection for 2 two-way switch
Telephone remote switch
10 A
366 0 052
Remote sensor 1, suitable for RAMSES 366/1 top and RAMSES 366/2 top
Remote sensor 2, with temperature adjustment suitable for RAMSES 366/1 top and RAMSES 366/2 top
26
907 0 191
907 0 192
Flush-mounted/wall mounting
Digital clock thermostat
6–30 °C 7d 24 h Holiday ±1h
auto
RAMSES 823 top, white (mains version)
RAMSES 821 top, white (battery version)
Technical data:
Switch load: Max. 6 (1) A 250 V~, at least. 1 mA 5 V....
Contact material: AgSnO
Time accuracy: 1 s/day at 20 °C
Time based on: Quartz
Control accuracy: ≤ ± 0.2 °C
Temperature display: accurate to 0.1 °C
Temperature setting range: +6 °C... +30 °C in 0.2
degree increments
Control type options: Pulse width modulation or
hysteresis controller
Control period: 5…30 mins
Control capture range: ± 0.2 K…5 K
Protection class: II in accordance with EN 60 730-1
Protection rating: IP 20 in accordance with EN 60529
Housing colour: pure white RAL 9010
2
RAMSES 822 top
Operating voltage: 230 V~,+10 %/–15 %
Frequency: 50 Hz
Power reserve: Approx. 5 hours, continuous heating
operation in the event of power failure
Contact: Two-way switch, floating, not for SELV
Digital controllers
RAMSES 822 top, white (mains version)
RAMSES 820 top, white (battery version)
RAMSES 822 top, mains version
• Digital clock thermostat in a low profile, attractive
design that can easily be integrated into any living
room
• Suitable for energy-saving room temperature control in
houses, apartments, heating zones, offices, showrooms,
factories, medical practices, holiday homes
• Fast and simple operation of the main day-to-day functions
• INFO key for viewing important settings
• Text line in the display provides a step-by-step guide to
programming
• The technically experienced user can set various individual control modes
• Optimal adaptation thanks to operating point and
switching differential setting option
• Quick start-up via 2 basic programs with individually
adjustable comfort and reduced temperature
• Individual program with 22 programmable time phases
also enables day-time reduced phases e.g. while out
at work
• Comfort and reduced temperature adjustable over
range of +10 °Cto +30 °C
• Frost protection option over range of +6 °C… +10 °C
• Party / ECO program with adjustable duration for comfort and reduced temperature without having to modify
standard program
• Fully automatic summer/winter-time correction
• Text guidance option available in 5 languages
• Holiday program with reduced temperature or datecontrolled heating phase, e.g. for holiday homes
• Plug-in base for flush-mounted socket with 3 or 4 wire
connection
RAMSES 820 top
Operating voltage: Battery operation,2 x 1.5 V AAA
alkaline batteries
Battery life: Approx. 1 year, depending on switching
frequency
Battery replacement time: Max. 10 min. with no loss
of time
Contact: Two-way switch, floating, suitable for SELV
RAMSES 820 top, battery version
as RAM 822 top however
• Digital clock thermostat with 2 or 3-wire connection,
voltage supplied via 2 x 1.5 V AAA batteries included
• Battery monitoring with battery replacement indicator
RAMSES 823 top, mains version
as RAM 822 top however
• Housing for wall mounting
Dimensional diagrams
118
Connection diagrams see page 28.
Installation
Individual room control
21
80
17
RAMSES 821 top, battery version
as RAM 820 top however
• Housing for wall mounting
Flush box
mounted
60
Combining the aforementioned clock
thermostats with Theben actuators
enables convenient, needs-driven
individual room control. The actuators are
simply screwed onto the individual radiators
or into the heating circuit distributor in underfloor
heating systems.
See page 39 for a detailed description.
Type
Installation
Program
Nominal
voltage
Temperature
Contact
range r/ m/f
RAMSES 822 top RAMSES 823 top
flush-mounted
wall-mounted
24 h/7 d Holiday program
230/240 V
50/60 Hz
+10 °C...+30 °C
1 two-way switch
6 (1) A
+6 °C...+10 °C frost protection
822 0 031
823 0 031
RAMSES 820 top RAMSES 821 top
flush-mounted
wall-mounted
24 h/7 d 2 x 1.5 V AAA
Holiday program
+10 °C...+30 °C
1 two-way switch
6 (1) A
+6 °C...+10 °C frost protection
820 9 011
821 9 011
Nominal current
at 250 V~
Order no.
27
Wall-mounted
Connection diagrams
OT BUS: 2-wire BUS between control device and switching unit. The BUS wire carries SELV.
Connection examples for RAMSES 822 top
OTBUS
6
2 3 4
OT-Box
RAM 816 top
M
7
–
M
2 3 4
OT-Box
RAM 816 top
+
ϑ
M
7
II
I
ϑ
13
Control of a 13
burner
15 16 17 18 19
closed
15 16 17 18 19
open
M
Forward flow temperature sensor
Digital controllers
5
4
3
62
1
OTBUS
Level II
L
N
Level I
5
4
3
2
1
L
N
RAMSES 816 top controls mechanical mixing valve
Control via the recirculation pump or storage/hot air
heating
OTBUS
6
2 3 4
OT-Box
RAM 816 top
M
7
II
I
Connection examples for RAMSES 820 top
ϑ
13
15 16 17 18 19
Level II
3
2
1
Level I
L
N
RAMSES 816 top controls 2 heating stages (2-stage blower, under-floor
heating, radiators etc.)
Control of a burner
OTBUS
OTBUS
6
2 3 4
OT-Box
RAM 817 top
M
7
–
M
2 3 4
OT-Box
RAM 817 top
+
ϑ
ϑ
12 13
Remote temperature sensor
Forward flow temperature sensor
M
7
–
M
ϑ
closed
open
M
RAMSES 817 top controls mechanical mixing valve
+
Control via the recirculation pump or storage/hot air
heating 12 13
15 16 17 18 19
15 16 17 18 19
L
N
28
3
2
61
closed
Forward flow temperature sensor
L
N
open
M
Wall-mounted
Connection diagrams
5
2
1
N
N
RF
>
N
L
RAMSES 701
TA
L
RAMSES 706
3
2
1
N
N
N
TR
TR
RF
ϑ
RAMSES 708
L
N
ϑ
ϑ>
RAM 741
L
N
L N
L
N
TA
1 2 3
L
ϑ
M
L
2
N
16 A
<ϑ
RF
RF
N
L
N
N
ϑ
ϑ
AB
RAMSES 709
RAM 746
N
RF
RAMSES 707
52
3
2
1
N
N
<
6
5
2
N
N
ϑ>
RF
L
N
ϑ>
N
TA
L N
L
N
RF
RAMSES 704
RF
RAMSES 705
L N
L
6
5
2
N
N
ϑ>
N
L
RF
RAMSES 702/703
6
5
2
N
N
L
N
6
5
2
N
N
>
>
L
TA
Digital controllers
2
1
N
N
RAMSES 741
RAM 748
L N
L
N
L
N
TA
L
N
TA
L
<ϑ
1 2 3
L
M
1 2 3
N
<ϑ
L
M
1 2 3
N
AB
RF
TR
N
L
N
L
ϑ
TR
RF
ϑ
ϑ N
L
M
N
TR
TR
ϑ
AB
AB
AB
RAMSES 746
RAMSES 748
L
N
L
N
L
N
L
N
2
1 2 3 1 2 3L
16 A
ϑ
L
N
N
N L
M
N
1
4
2
1
1
TR
AB
RAMSES 714/714 A
L
N
ϑ
M
L
N
1 = Electric standby-by heating
2 = Ventilator/air-conditioning
ϑ
ϑ
AB
SOTHIS 715
Heating/actuator/magnetic valve/burner/circulation pump/night storage blowers
Electric standby-by heating
29
Wall-mounted
CO2 sensor for ventilation control and monitoring of air quality in the room
AMUN 716
Suitable for conference and meeting rooms, offices,
schools/nurseries, passive and low-energy housing
without controlled ventilation.
AMUN 716 R
New
AMUN 716 USB
AMUN 716 R switch and analog outputs
• CO2 sensor for automatic ventilation control
• 2 CO2 controlled switch outputs for 2 stage control
• 3 x 0–10 V outputs for CO2, temperature and relative
humidity
• Switch output with manual and automatic operation
as well as display of switching status
• Warning display for CO2 concentration (lights)
• Simple wall or flush mounted alternatives
• Optionally available power unit for flush-mounted
installation
• Simple upgrade of uncontrolled ventilation systems
possible
AMUN 716 USB
• Simple start-up and use on PC via USB interface
• Graphical representation of CO2 levels on PC
• Representation of course of last 80 minutes using
diagrams
• Additional display of current CO2 level on sensor
via 5 LEDs
• Acoustic and visual warning signals on reaching the
limit value
• Adjustable acoustic alarm threshold
• Log file of CO2 levels can be saved
• Saves automatically during extended recordings
• Maintenance-free sensor through sealed measuring unit
• Software for Windows 98 SE/ME/2000/XP
Other
CO2
Carbon dioxide is only life-threatening at a concentration
above 20% but well-being, concentration and performance
are all unconsciously affected at levels above 0.08%. DIN
1946 recommends a maximum value of 0.1 %. This value
is often exceeded given modern building standards and the
high level of air tightness. Human beings become tired and
lose concentration. The CO2 sensor for monitoring indoor air
quality uses LEDs to display the CO2 level in the room.
CO 24 h
2
Technical data:
AMUN 716 R
Operating voltage: 14–48 V DC or 16–36 VAC
50–60 Hz
Measuring range for 0–10 V outputs:
0–2000 ppm CO
5 °C–40 °C
20–100 % rF
CO2 switched thresholds:
NO contact 1:700 ppm± 200 ppm
NO contact 2:1300 ppm± 200 ppm
Setting via ratcheted pentiometer in 100 ppm stages
Hysteresis: ± 75 ppm in relation to set value
Protection class: II in accordance with EN 60730-1
Protection rating: IP 20 in accordance with EN 60529
2
AMUN 716 USB
Operating voltage: 5 V DC via USB bus voltage
Measuring range: 0–5000 ppm CO
Protection class: III in accordance with EN 60730-1
Protection rating: IP 20 in accordance with EN 60529
2
200 000
Für den Menschen letal (tödlich)
100 000
Verlöschen einer Kerze
40 000…50 000
Ausatem-Konzentration
des Menschen
5 000
Maximale ArbeitsplatzKonzentration (MAK-Wert)
4 000
Schlecht gelüftetes Zimmer
1 000
Gefühl von schlechter Luft
330…350
Außenluft
CO levels
2
95
Type
description
Measuring range
Display
AMUN 716 USB
AMUN 716 R
Power unit
30
60
97
AMUN 716 R dimension diagrams
97
AMUN 716 USB dimension diagrams
30
60
95
Data interface
Order no.
0-5000 ppm
5 LEDs
USB716 9 101
CO2sensor incl.software
CO2 sensor with 2 relay outputs
0-2000 ppm
6 LEDs
3 x 0–10 V716 0 101
24 V/12 W flush-mounted power unit
907 0 494
Wall-mounted
Hygrostat, 74 x 74 mm
5-30 °C
SOTHIS 715
• SOTHIS 715 humidity stat in attractively designed
installation housing
• Setting range 35...100 % rF
• Floating two-way switch: humidifier 2 A/250 V~;
dehumidifier 5 A/250 V~
• Designed for the control of air humidity or ventilation
and dehumidifier systems, not for SELV
• Measurement of air humidity via molecular chain
alterations in polymer artificial fibres
• Use SELV where there is risk of dripping water or
build up of condensation in the housing
• White housing, 74 x 74 (mm)
SOTHIS 715
Technical data:
Operating voltage: 230 V, +10 %/–15 %, 50–60 Hz
Two-way switch: Humidifier 2A/250 V~
Dehumidifier 5 A/250 V~
Protection class: II in accordance with EN 60730-1
subject to designated installation
Protection rating: IP 30 in accordance with EN 60529
Housing colour: pure white (RAL 9010)
Connection diagrams see page 29.
Wall-mounted
Other
Hygrostat, 74 x 74 mm
� 67
Dimensional diagrams
� 74
� 79
5
7.5
23.3
28
Type
description
Setting range
Contact
Order no.
SOTHIS 715
Hygrostat
Adapter plate for flush mounted socket 79 x 79 mm
715 0 002
907 0 212
35…100 % rF
Two-way switch, 2/5 A, 250 V~
31
Din rail program
Digital time switches 1–2 channels (2 modules)
7d 24 h ±1h
PC
auto
Digital time switches with text-oriented user
guidance in the display, OBELISK interface and
DuoFix plug-in terminals.
V
TR 610 top2
Functions:
• Daily and weekly program
• Operating by means of 4 keys arranged in one row
• Integrated running-time meter for max. 500.000 hours
with reset option and service function for monitoring of
maintenance intervals and „Service“ display, separately
for each channel
• Plug-in spring terminals, each one accepting 2 conductors, wires or strands
• Display illumination (can be switched off)
• Interface for OBELISK top2 memory card for PC programming, 2nd switching program to be plugged in,
copying of programs and safe storage of the program
• Date-controlled holiday program
• Automatic summer/winter time changeover can be
alternatively switched off or randomly programmed
(MEZ, GB, USA changeover norm selectable)
• Preset ex factory of date, time and summer/winter
changeover
• Extended temperature range –30 °C ... +55 °C
• High accuracy: ± 0,5 s/day
• 10 years power reserve by lithium cell
• Zero cross switching for relay-saving switching and high
lamp loads
• Switching preselection
• Permanent switching ON/OFF
• PIN encoding
TR 610 top2 Termina ®
• 1 channel with 56 memory locations, EEPROM
V
T R 612 top2 Termina ®
• 2 channels with 56 memory locations, EEPROM
Dimension drawings DIN 43 880
Terminal cover
69.2
63.7
45.1
90.1
52.9 *
2
Design
• Standarrdized housing 45 x 35 x 60 mm according to
DIN 43 880
• Quick fastening for 35 mm profile rail (DIN EN 50 022)
• Contact protection according to accident prevention
regulation BGV A3
• Top mounting with additional terminal cover, sealable
• Control panel installation using mounting kit
No. 907 0 001
• Undetachable hinged cover with possibility of keeping
the memory card OBELISK top2, sealable
35.8
35.8
128.2 *
Other
TR 612 top2
Common technical data:
Nominal voltage: 230–240 V~, +10 %/–15 %
Frequency: 50–60 Hz
Type of contact: changeover switch
Contact:
independent of mains phase (zero cross switching)
Opening width: < 3 mm
Contact material: AgSnO
Max. switching capacity: 16 A, 250 V~, cos ϕ = 1
10 A, 250 V~, cos ϕ = 0.6
Min. switching capacity: 10 mA at 230 V AC
100 mA at 12 V AC/DC
Power consumption: typ. 3 VA
Incandescent lamp load: 2600 W
Halogen lamp load: 2600 W
Fluorescent lamps:
non compensated, series compensated 1000 VA,
parallel compensated 730 VA (80 µF)
Compact fluorescent lamps:
22 x 7 W, 18 x 11 W, 16 x 15 W, 16 x 20 W, 14 x 23 W
Time basis: Quartz
Accuracy: ≤ ± 0,5 s/day at +20 °C
Shortest switching time: 1 minute (pulse/cycle 1 s)
Switching precision: exact to the second
Display: backlit LCD display with text line
Operating control elements: 4 touch keys
Power reserve:
about 10 years with autosleep allowing full operation
(temperature +20 °C) by non-polluting lithium cell
Admissible ambient temperature:
–30 °C...+55 °C
Housing- and insulation material:
self-extinguishing thermoplasts of high temperature
resistance
Protection class:
II according to EN 60 730-1 subject to correct installation
Degree of protection: IP 20 according to EN 60 529
Weight: approx. 170 g
Test approvals: V
60 *
76.2 *
*with terminal cover
Type
Program
Memory
locations
Programmable
every ...
Control
inputs
Memory card OBELISK top2
included in the delivery
TR 610 top2
56
1 min
–
–
24 h/7 d,
1 channel
runtime meter, holiday
TR 612 top2program
56
1 min
–
–
2 channels
OBELISK top2 programming kit (memory card, plug-in adapter, software) for Windows 2000/XP
OBELISK top2 memory card (single)
Terminal cover for wall mounting, sealable
32
Switching
contacts
Nominal current
at 250 V~
Order No.
1 changeover switch
16 (10) A
610 0 100
2 changeover switches
16 (10) A
612 0 100
907 0 409
907 0 404
907 0 064
Socket devices
Analogue socket timers
n-timer
be
NT
year
IE G U A R
A
A
NT
EE
Jahre
GAR
theben-timer 26 day
Function:
• C
ompact time program connector e.g. for circulation
pumps
• Without connecting lead for direct insertion in socket
• Standard electrical devices, lights, washing machines etc.
can automatically be switched on or off as required
• Simple program setting via folding segments
• Manual switch for instantly switching connected electrical devices on or off without affecting the subsequent
program sequence
• ON/OFF status display
26
the
7d 24 h
theben-timer 26 with segments
• Daily time program can be set at 15 min segments
theben-timer 27 with segments
• Weekly time program can be set at 2 hour segments
theben-timer 26 IP 44 with splash guard
• D
aily time program can be set at 15 min segments
• Splash guard for wet rooms and outdoors
• Permissible ambient temperature: –40 °C... +55 °C
• Clear plastic cover
theben-timer 26 IP 44
Technical data:
Nominal voltage: 230 V, ± 10 %
Frequency: 50 Hz
Power consumption: max. 0.8 VA
Contacts: Opening width less than 3 mm (µ)
Contact material: Solid silver
Switching capacity: 16 A, 230 V~, cos ϕ =1
4 A, 230 V~, cos ϕ =0.6
Time accuracy: in accordance with mains frequency
Permissible ambient temperature: -10 °C... +55 °C,
theben-timer 26 IP 44: –40 °C... +55 °C
Housing and insulation material:
high-temperature resistant, self-extinguishing
thermoplastic
Protection class: I in accordance with EN 60 730-1
Protection rating: IP 20 in accordance with EN 60 529
theben-timer 26 IP 44 in accordance with EN 60 529
Test approvals: national and international
according to type of device V T W F A
Weight: approx. 160 g
Type
timing disc
Special function
Program
ability of all ...
Shortest
switching segments Housing colours: Nominal current
Switching interval
at 230 V~
Order no.
theben-timer 26
theben-timer 26 IP 44
theben-timer 27
15 minutes
15 minutes
2 hours
15 minutes
15 minutes
2 hours
026 0 030
026 0 855
027 0 930
24 h
24 h
7 days
Switching pre-selection
Switching pre-selection
Switching pre-selection
96
96
84
white
white
white
16 (4) A
16 (4) A
16 (4) A
Socket devices
Digital time program connector
7d 24 h
theben-eltimo 020 S DCF
Type
Program
Memory
locations
Technical data:
Nominal voltage: 230 V~, ± 10 %
Frequency: 50 Hz
Power consumption: max. 5 VA
Contact: Opening width less than 3 mm (µ)
Contact material: Ag Sn O
Switching capacity: 16 A, 230 V~, cos ϕ =1
2 A, 230 V~, cos ϕ =0.6
Time based on: Quartz/DCF synchronized
Time accuracy:
≤ ± 1 s/day at 20 °C (quartz)
Switching accuracy: to the second/radio signal
Display: LCD display of time, switching time, switching
status, manual and random operation
Permissible ambient temperature: -10 °C...+40 °C
Protection class: II in accordance with EN 60 730-1 for
housing
Protection class: I for plug system
Protection rating: IP 20 in accordance with EN 60 529
Weight: approx. 170 g
Other
theben-eltimo 020 S
• Electronic digital timer in modern design
• Daily and weekly program with 36 available switching
times and free weekday block formation
• Automatic summer/winter time switchover
• Simple operation via keys for weekdays (d), hours(h) and
minutes (m) as well as keys for entering time (E), program
entry (Prog), random switching(z) and
manual switching (i)
• Random switching: Power-on time ranges from 10–120 min
• Manual switch for or early switching on or off and
permanent operation
• Switching status display
• Mains independent program entry
• Permanent program storage via EEPROM
• Power reserve via NiMH rechargeable battery:
500 hours life
• 3500 W switching capacity
DCF77
2
theben-eltimo 020 S DCF
• as above but includes DCF77 radio receiver
• Automatic summer/winter time switchover
• 33 memory locations
Mains independent
Program storage
Program
Switching times
ability of all ...
theben-eltimo
020 S
24 h/7 days
36
Random operation
500 h
1 minute
NiMH rechargeable battery
.
theben-eltimo
020 S DCF
24 h/7 days
33
Random operation
500 h
1 minute
NiMH rechargeable battery
.
housing
colour
Nominal current
at 230 V~
Order no.
from 1 min to 24 h
light blue
16 (2) A
/. 1 min, random operation
020 0 000
from 1 min to 24 h
light blue
16 (2) A
/. 1 min, random operation
020 0 300
33
Front panel/distributor installation
Operating hours counter
99,999 h
Operating hours counter for monitoring burners,
heating pumps etc.
BZ 142, BZ 143
Function:
• Operating hours counter with synchronous motor drive
• For installation on control panel or wall
• Versions for direct voltage with quartz-controlled stepper motor
• Counter range up to max. 99,999.99 hours
• Progress display
BZ 142/143
Design BZ 142-1, BZ 143-1:
• Front panel devices with click-in or stretch clamp supports for walls up to a maximum of 10 mm thick
• Clamp or flat plug connection 6.3 mm
BZ 142-3 with plug-in base
Design BZ 142-3:
• with plug-in base for wall installation (terminal cover
required)
• Plug-in base with quick fastening for 35 mm profile
rails (DIN EN 50 022)
• Terminal screws
• Contact protection to comply with accident prevention
regulation BGV A3
• Housing colour: anthracite
Technical data:
Operating voltage: 230 V~, ± 10 %
Special voltage: See appendix:
Frequency: 50 Hz
Power consumption: approx. 1 VA
Permissible ambient temperature
with BZ 142/143: –20 °C... +70 °C
with BZ 145: –10 °C... +70 °C
Counting range: 99,999.99 hours without reset
Number size: 1.5 x 3.5 mm,white on black, decimal
places black on white
Protection class: II in accordance with EN 60335-1 subject to designated installation
Protection rating with BZ 142/143: Front frame IP 65
in accordance with EN 60529
with BZ 145: IP 65 in accordance with EN 60 529
Test voltage: 2500 V~ winding and contact versus mass
Weight with BZ 142/143: approx. 50 g with BZ 145: Approx. 70 g
Design BZ 145:
• Standard housing 45 x 35 x 60 mm in accordance with
DIN 43 880
• Distribution installation device with quick fastening for
35 mm profile rails (DIN EN 50022)
• Top mounting with additional terminal box cover plate,
sealable
• Control panel installation with assembly kit
- no. 907 0 001
• Contact protection to comply with accident prevention
regulation BGV A3
• Captive terminal screws
BZ 145
Dimension diagrams in accordance with DIN 43 880
65,5
60
52,9*
45
85,85
128,2*
Other
35,3
60*
72,5
*with terminal box cover plate
Type
Counting range
Installation
BZ 142-1 99,999.99 h
Front plate
mm
Front panel installation with spring closer or terminal clamps
48 x 48
(order no. 907 0 043)
Integrated part
mm
Order no.
46 x 46
142 0 721
Baffle 72 x 72 mm for BZ 142-1
Baffle 55 x 55 mm for BZ 142-1
907 0 074
907 0 041
BZ 142-3 99,999.99 h
142 0 723
Plug-in socket (order no. 907 0 042) with quick fastening
48 x 48
for 35 mm standard mounting rail (included)
46 x 46
Additional terminal cover required for wall installation
BZ 143-1 99,999.99 h
Front panel installation with click-in or stretch clamp fixings (order no. 907 0 043) incl.
52 x 52
46 x 46 or Ø 50
BZ 145
99,999.9 h
Distributor installation with quick fastening for 35 mm profile rails
35 x 45
35 x 45 (depth 60)
Terminal box cover plate for top mounting, sealable
34
907 0 075
143 0 721
145 0 000
907 0 064
KNX
Room thermostat and
multifunction display
35
Wall-mounted
Room thermostat and multi-function display
VARIA 826 KNX
Room temperature controller with display and
integrated time switch (clock thermostat).
• E asy to clean and scratchproof glass cover in white
• E asy to use aluminium pushbuttons.
• B ackground lighting, dimmable
• Integrated heating control and, if required, control of
cooling/ventilation systems
New
New
Features
•U
p to 7 different editable display pages
• F reely configurable for displaying and controlling functions e.g. light scenes, sun protection systems (40 values/functions)
•A
utomatic summer/winter time adjustment with power
reserve
•C
ontrols up to 8 rooms via own temperature profiles
•W
eekly time switch with 8 channels with up to
3 different statuses, e.g. for light, shutters, fans etc.
• 3 heating programs
•C
an be configured as continuous or on/off control
•O
perating modes: comfort, standby, temperature
reduction at night Frost protection
•A
lso for fan coils, e.g. Theben fan coil actuator
•D
etails from the Theben weather station can be displayed (with min/max values, e.g. for temperature).
• F ree choice of programming via the ETS without plug-in
•D
isplay of physical address
• Reception
and display of 14 byte text strings
(e.g. music title)
• Installation in flush-mounted socket
VARIA 826 KNX
VARIA 824 KNX
Technical data:
VARIA 826 KNX
Operating voltage: 230 V, 50 Hz, ±10 %
Power draw from the mains: < 2.5 VA
Bus power draw: <8 mA
Bus connection: Bus terminal
Display: Dot matrix display with 132 x 72 points
Display lighting: LCD with white backlighting, dimmable
Display: 8 lines with different functions
available e.g. title, switching, dimming, %-value (EIS 6),
blinds/shutters, heating/ventilation/air conditioning, 8 bit
counter value, temperature, 2 byte value (EIS 5), 8/16 bit
counter value
Power reserve: 1.5 years
Permitted operating temperature: 0 °C... + 45°C
Protection rating: IP 20 in accordance with EN 60529
Housing:
approx. 93 x 128 x 15 mm (VARIA 826 KNX)
approx. 80 x 118 x 17 mm (VARIA 824 KNX)
Central functions
VARIA 824 KNX
as with VARIA 826 KNX but including
•W
hite plastic housing
• L arge keys
•D
isplay pages can be selected via slide switch
Lighting control
Conservatory
control
Settings
Product database and manual see www.theben.de
36
4
118
118
17
17 21
80
93.4
128
45.6
18.1
80
KNX
Dimensional diagrams
Type
Order no.
VARIA 826 KNX
826 9 200
824 9 200
21 VARIA 824 KNX
EIB/KNX program for room temperature control
RAMSES 712 KNX
Flush-mounted
installation
not including housing
RAMSES 713 S EIB/KNX
RAMSES 713 FC KNX
RAMSES 712 KNX
Individual room thermostat for controlling heating
actuators or motorised actuators
•Wall installation with integrated bus coupling unit
•Optional installation in flush-mounted sockets with
rear-ventilated covers (without housing).
•An external sensor can be connected to the sensor
for floor temperature monitoring.
•The RAMSES 712 KNX can be used both as an on/off
controller (also combinable).
•With 2 binary inputs, can be reconfigured to outputs
for connecting LED (with communication object) display
of ON/OFF.
•Free allocation of functions: Switch/key, dimming, blinds,
valuator, counter, LED control
•Measurable temperature range -20 °C …+60 °C
Technical data:
Operating voltage: Bus voltage (< 10 mA)
Permitted operating temperature: –5 °C … + 45 °C
Output with LED configuration: Low current 1 mA (LED
1 mA types)
Max. interface extension: 5 m
Protection class: II
Protection rating: IP 20
Dimensions: 74 x 74 x 28 mm
RAMSES 713 S EIB/KNX
Continuous individual room controller with bus coupling
unit. Available functions: continuous control or on/off
control, heating (radiator, underfloor heating), 2 stage
heating, heating and cooling
• Manual switch for presence or operation mode: comfort,
standby, temperature reduction at night, frost protection
• Inputs can also be used for external temperature sensor/
floor temperature limiters, window contacts, presence
detectors
Technical data:
Setting range: +10 °C…+28 °C
Temperature limitation: through external floor sensor
+5 °C…+48 °C
Temperature sensor: (IP 65) encapsulated with 4 m
connecting cable
Operating voltage: Bus voltage (≤ 10 mA)
Protection rating: IP20 in accordance with EN 60529
Housing: 80 x 84 x 27 mm
RAMSES 713 FC KNX
Individual room temperature control for controlling
fan coil heaters
•Manual switch can be used as operation mode selector
for OFF, auto or fan stages 1,2 or 3.
•LEDs display heating (red) or cooling (blue) status or
whether the desired temperature has been reached
• Inputs can also be used for external temperature sensor/
floor temperature limiters, window contacts, presence
detectors
Technical data:
Operating voltage: Bus voltage (≤ 10 mA)
Setting range: 10 °C… 28 °C
Measuring range: 0 °C… 40 °C
Temperature limitation: through external floor sensor
5 °C…48 °C
Temperature sensor: (IP 65) encapsulated with 4 m
connecting cable
Protection rating: IP 20 in accordance with EN 60529
Housing: 80 x 84 x 27 mm
FCA 1 KNX
FCA1 actuator, for 1-3-stage control of fan coils with
heating or cooling valve
Control of on/off valve and 3 point valve additional relay
possible for control of either an electric heater bank or an
electric cooler bank. For 2- or 4 pipe systems Window
contact and condensation monitoring
Technical data:
Operating voltage: 230 V AC, ±10 %, 50-60 Hz
Power draw: < 3 VA
Switching capacity valves (triacs):
0.5 A (24–230 V AC)
Switching capacity, additional relay: 16 A
Switching capacity, fan relay: 8 A
Permissible ambient temperature: -5 °C ... +45 °C
Protection rating: IP 20 in accordance with EN 60529
Housing: 90 x 72 x 60 mm (4 TE),
KNX
FCA 1 KNX Fan coil actuator
Type
Function
Order no.
RAMSES 712 KNX
RAMSES 713 S KNX
RAMSES 713 FC KNX
FCA 1 KNX Floor sensor KNX Individual room thermostat without rotary control
Individual room thermostat with rotary control
Fan coil room thermostat with rotary control
Fan coil actuator
IP 65, 4 m connecting lead
712 9 200
713 9 201
713 9 202
492 0 200
907 0 321
37
EIB/KNX program for room temperature control
HMT 6 KNX 6 channel heating actuator for control
of thermal drives
HMT 6/HMT 12 KNX
Cheops drive KNX
Cheops control KNX
HMT 12 KNX 12 channel heating actuator for control
of thermal drives
• Housing is particularly designed for installation in
heating circuit distributors
• Straight forward wiring of drives (24 V~)
• Can be installed directly on a wall or a rail in the
heating circuit distributor
• Integrated power unit with mains plug for connection
of up to13 thermal drives (24 V~)
• Choice of constant or variable actuating values
• Summer mode prevents unintentional heating in the
summer (valve protection option in summer mode)
CHEOPS control KNX
Motorised drive with independent control and
temperature recording
• Independent room temperature control, manual
operation possible via 2 keys on the device
• Display via 5 LED’s
• Fully automatic valve stroke recognition which
dynamically adjusts the set path
• External temperature sensor or temperature limiter
for underfloor heating
• Simple installation via rastering on valve adapter
(valve adapter included in the scope of supply for
all current valves)
CHEOPS drive KNX• Motorised drive as above but
without control
• Stroke display (setting position) via 5 LEDs (red)
HMG 4 KNX (basic device)
• 4 channel heating actuator
HME 4 KNX (upgrade device)
• 4 channel upgrade module (for upgrading to max.12
heating channels)
KNX
HMG 4 KNX
Basic device, 4 channels
HME 4 KNX
Upgrade device , 4
channels
Description
The heating actuator optimises the effect when using room
temperature controls in conjunction with thermal actuators
and enables the integration of a boiler control. Circulation
pump can be directly controlled via the actuator.
• S ilent semiconductor switch
• 4 floating outputs 24–250 V AC
•U
p to 5 positioning actuators per channel
•C
ontinuous or switching control variable selectable
• E mergency program in case of bus and telegram failure
• S ummer mode and valve protection
•M
inimum and maximum actuating value can be set
•D
etermination of maximum control variables in all
channels, including boiler control, enables energy
savings of up to 30 %
Technical data:
Operating voltage: 230 V/24 V AC
Max. power draw: 50 W
Fuse: T 2 A
Max. number of drives: 13
Heating program options: 2
Dimensions H/W/L: 70 x 75 x 302 mm
Protection class: II subject to designated installation
Protection rating: IP 20 in accordance with EN 60529
Flexible lead*: 1.0–1.5 mm2
* Drive leads can be fitted ex works
with wire end sleeves.
ALPHA 4 24 V~ actuator
• See page 39 for technical details of actuator
Technical data:
Operating voltage: Bus voltage
Emergency program: Available position
Operating temperature: 0 °C ...+50 °C
Medium temperature: ≤100 °C
Protection rating: EN 60529 – drive: IP 21– control: IP 20
Protection class: III, EN 60730-2-14
Max. valve stroke: 7,5 mm
Detection of valve limit stops: Automatic
Approved valves: Actuator with valve adapter for Danfoss
RA, Heimeier, MNG, Schlösser from 3/93, Honeywell
Braukmann, Dumser (distributor), Reich (distributor), Landis
+ Gyr, Oventrop, Herb, Onda
Technical data:
Voltage: 230 V AC, ± 10%, 50 Hz
Power take up: < 2.5 VA
Power supply from the bus (basic module only)
Power supply: < 10 mA (incl. 2 upgrades)
Connection: KNX bus terminals
Output: Triac
Quantity: 4
Switching capacity: 0.5 A, up to 5 therm. Actuator/output
Connection cross-sections: solid 0.5 mm2 (Ø 0.8) to
4 mm2 strand with wire end sleeve: 0.5 mm2 to 2.5 mm2
Permissible ambient temperature: -5 °C ... +45 °C
Protection class: II subject to designated installation
Protection rating: IP 20 in accordance with EN 60529
Housing: 45 x 72 x 60 mm (4 TE)
Please request the new KNX catalogue with lots
of other solutions for building automation.
Type
Channels
Output
HMT 6 KNX
6
6 x Triac 24 V AC
HMT 12 KNX
12
12 x Triac 24 V AC
CHEOPS control KNX
With valve adapter for: Danfoss, RA, Heimeier, MNG, Schlösser from 3/93,
CHEOPS drive KNXHoneywell,Braukmann, Dumser (distributor), Reich (distributor), Landis
+ Gyr, Oventrop, Herb
Operating voltage
230 V/50 Hz and Bus
230 V/50 Hz and Bus
Bus
Bus
Order no.
490 0 273
490 0 274
732 9 201
731 9 200
Type Special function
Output
Nominal current
at 250 V~
Order no.
HMG 4 EIB/KNX
HME 4 EIB/KNX
4 x 2 A
4 x 2 A
491 0 210
491 0 211
38
heating actuator basic device, 4 rotary switches, 4 LED displays 4 x Triac
Add-on device, 4 rotary switches, 4 LED displays
4 x Triac
Accessories:
Actuator for individual room control
ALPHA 4 actuator for individual room control enables customised temperature reduction
Theben provides the elegant solution for new build and modernisation. The reliable RAMSES clock thermostat combined
with an electro-thermal actuator makes it possible to upgrade
existing systems to individual room control. Extremely easy
to install as the heating pipes do not need to be changed.
Thanks to a wide range of adapter pieces, these electro-thermal actuators can be installed on practically any radiator. Any
Theben clock thermostat can be combined with one or more
drives to control rooms such as, for example,living rooms,
bedrooms, kitchens or offices to meet your individual requirements. Automatic reduction in room temperature when empty
or at night makes it possible to reduce energy consumption
by up to 20 %.
A Theben clock thermostat or thermostat is required
for controlling the following actuators.
ALPHA 4 actuator
VA 78
ALPHA 4 230 V~ actuator
• Attractive actuator for radiators, heating circuit distributors or individual heating circuits
• "First open function" for easy installation and heating
start up
• Plug-in installation on valve adapters
• 100% protection against damaging drives through leaking valves
• Function and adjustment checking
• Protection against disassembly by means of removable
SaveGuard
• Guaranteed surge protection
VA 80
Valve adapter
(not included in the scope of supply)
ALPHA 4 24 V actuator
• Actuator as before, but for 24 V AC/DC
Common technical data:
Operating voltage: 230 V AC, 50/60 Hz
24 V, 0–60 Hz
Function principle: Silent, flexible element
Valve without current: Closed
Switch-on power level: max. 300 mA for max. 200 ms
max. 250 mA for max. 2 min
Nominal output: 1.8 W
Closing/opening times: Approx. 2.5 min
Stroke: 4 mm
Spring tension: 100 N, ± 5 %
Permissible ambient temperature: 0 °C… 60 °C
Storage temperature: –25 °C… 60 °C
Protection rating: IP 54 in accordance with EN 60529
Protection class: II in accordance with EN 60 730-1
Length of insertable connection line: 1000 mm
Housing colour: White (RAL 9003)
Housing: 60 x 44 x 61 mm (H/W/L)
Unscrew
at valve
thermost
ua-
Attachact
tor
Installation without affecting the water supply.
Further valve adapters on request:
Valve adapter VA 78
• Valve adapter for Danfoss RA
Valve adapter VA 80
• Valve adapters for Onda, Schlösser(from 1993), Oventrop
(M30 x 1.5), Heimeier, Herb, Therm-Concept, Frank, Roth
(distributor), Dinotherm (distributor).
Radiator heating control:
VA 02
M 30 x 1.5
Velta
VA 16
M 28 x 1.5
Herz
VA 16 H
M 28 x 1.5
Poly Therm
VA 26
flange
Giacomini
VA 59
Danfoss RAVL
VA 81
M 30 x 1.5
Cosmotherm, Cosmoline (GC distributor),
Strawa
Individual under-floor heating circuit control:
1
2
3
4
5
6
7
Living room
Kitchen
Bathroom
Work room
230 V~
24 V~
L1
N
sing isolation
SELV when u ormer
transf
Connection example
of RAMSES clock
thermostat
Type
Order no.
ALPHA 4 230 V~ actuator 907 0 438
Actuator ALPHA 4 24 V907 0 439
Valve adapter VA 78
907 0 436
Valve adapter VA 80907 0 437
39
KNX
R
N
Subject to technical changes and improvements.
2409
9900606
Theben AG
Hohenbergstraße 32, 72401 Haigerloch, GERMANY
Postfach 56, 72394 Haigerloch, GERMANY
Phone +49 (0)74 74/6 92-0Fax +49 (0)74 74/6 92-150
E-mail: [email protected], www.theben.de

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement