Nordpeis Quadro is a clean-burning stove with secondary combustion, designed to provide efficient and environmentally friendly heating. Its key features include:
- Adjustable air vent control for precise regulation of combustion and heat output.
- Top and rear flue outlet options for flexible installation.
- Easy assembly with the necessary tools and step-by-step instructions provided.
- User-friendly operation with a simple control lever for adjusting the air vent.
- Durable construction with cast iron and sheet steel materials, ensuring longevity.
advertisement
NO Brukerveiledning
GB User manual
DK Brugervejledning
SE Installations- och bruksanvisning
2
10
16
22
FI Käyttöohje 28
Quadro
Product no: SN-QUADR-0XX
RRF no:
Sintef Nr:
40 09 2200
110-0339
Last updated: 03.09.2012
INDEX
1. Prior to assembling the stove
Chimney draft
10
10
Air Supply 10
Dimensional drawing 11
2. Technical Information
3. Distance to combustible material
11
11
4. Assembly 11
Operation 11
Operating control
Flue outlet collar
Air supply set
Connection of the flue
11
11
12
12
5. Lighting the fire for the first time 12
6. Maintenance
Cleaning and inspection
Ashes 12
Thermotte™ Plates
Door and glass
Recycling of the ceramic glass
12
12
12
13
13
7. Warranty
8. Advice on lighting a fire
13
13
Some advice in case of combustion problems 15
1. Prior to assembling the stove
All our products are tested according to the latest
European requirements and also
to the Norwegian
standard NS 3058 and NS 3059, which include particle tests. However, several European countries have local regulations for installation of fireplaces, which change regularly. It is the responsibility of the client that these regulations are complied with in the country/region where the fireplace is installed. Nordpeis AS is not responsible for incorrect installation.
Important to check
(please note that this list is not exhaustive):
• distance from firebox to combustible/flammable materials
• insulation materials/requirements between fireplace surround and back wall
• size of floor plates in front of fireplace if required
• flue connection between firebox and chimney
• insulation requirements if flue passes through a flammable wall
Chimney draft
Compared with older models, the clean burning stoves of today put significantly higher demands on the chimney. Even the best stove will not work properly if the chimney does not have the right dimensions or is not in good working order. The draught is mainly controlled by gas temperature, outside temperature, air supply as well as the height and inner diameter of the chimney. The diameter of the chimney should never be less than that of the flue/chimney collar. For draft requirements at nominal heat output, see technical table
The draught increases when:
•
The chimney becomes warmer than the outside air
• The active length of the chimney over the hearth increases
• Good air supply to the combustion
It can be difficult to obtain the right draught conditions in case the chimney is too large relative to the stove, as the chimney does not heat up well enough. In such cases you may want to contact professional for evaluation of possible measures. Draught that is too strong can be controlled with a damper. If necessary, contact a chimney sweeper.
10
GB
Air supply
A set for fresh air supply is available as accessory.
This will ensure that the air supply to the combustion chamber is less affected by ventilation systems, kitchen fans and other factors which can create a down-draught in the room. In all new construction, we strongly recommend that it is designed and prepared for direct supply of outside air. In older houses, the use of fresh air supply set is also recommended . Insufficient air supply can cause down-draught and thereby low combustion efficiency and the problems that this
entails: soot stains on the glass, inefficient use of the wood and a soot deposits in the chimney.
Dimensional drawing
The illustrations indicate the approximate centre height of the recess for the flue. Consider possible inclination of the flue prior to perforating the chimney. Distortions in floors and walls may also influence the height. Place the stove for accurate height and positioning of the flue/ chimney connection.
For your own safety, comply with the assembly instructions.
All safety distances are minimum distances. Installation of the stove must comply with the current rules and regulations of the country where the product is installed. Nordpeis AS is not responsible for wrongly assembled stoves.
Subject to errors and changes.
For the latest updated version go to www.nordpeis.com.
Refueling interval
Opening of the air vent control
50 min
33%
Operation:
Intermittent*
* Intermittent combustion refers to normal use of a fireplace, i.e. new wood is inserted when the previous load has burned down to ember
3. Distance to combustible material
Ensure that the safety distances are respected
(FIG 1).
When connecting a steel chimney to the top outlet use the security distances required from the manufacturer.
2. Technical Information
The stoves from Nordpeis have secondary combustion and are clean burning. The combustion takes place in two phases: first the wood burns and then the gases from the fumes are lit by the hot air. This ensures that these new stoves have minimal emissions of soot particles and unburnt gases (such as CO) and are thus better for the environment. Clean burning stoves require a small amount of wood in order to obtain a good heat output. Use exclusively clean and dry wood.
We recommend seasoned hardwood with a moisture content between 16% and 20%.
Material
Surface treatment door/ doorframe
Fuel
Operating range
Efficiency
CO % @ 13% O
2:
Draught system
Cast iron / sheet steel
Heat resistant varnish
Wood logs, 30 cm
6,2 kW
80,4%
0,12
Combustion system
Air vent control
Secondary combustion
(clean burning)
Heating area
Flue outlet:
Flue
Flue gas temperature
45-120 m²
Top and rear
Inner Ø 150 mm
Weight Quadro 1
Weight Quadro 2
Weight Quadro 3
104 kg
113 kg
118 kg
Weight Quadro High To
14 kg
Air supply requirements
(m³/h)
Fuel charge
277 °C
13
1,4 kg
4. Assembly
The following tools are necessary:
•
4mm and 5 mm Allen Key
•
6mm, 10mm and 13 mm Wrench
Operation
FIG 3: Adjustment of the door. Loosen the screws
position the door correctly and fasten the
screws again
FIG 4: The air vent control is adjusted with the lever
placed on the left side of the stove
FIG 5: The Thermotte elements
FIG 6-8: Screws for adjusting the levelling of the stove
Operating control
When the stove is in position, check that all functions are easy to manoeuvre and appear satisfactory.
Door
Handle turned outwards
Handle parallel with door frame
Air vent control (FIG 6)
Forward
Back
Open
Closed
Removal of self closing mechanism FIG 19
Open the door and loosen the set screw with a 3mm
Allen key.
Open
Closed
GB
Flue outlet collar
Quadro is delivered as standard with a top flue outlet collar. In order to change to a posterior mounted flue outlet:
11
FIG 9: Remove the loose top lid
FIG 10: Remove the perforated decoration lid in the back with a hammer, or a hacksaw
FIG 11: Unscrew the rear sheet steel lid
FIG 12: Unscrew the top collar. The draft diverter will also losen
FIG 13: Fasten the collar on the posterior flue outlet
FIG 14: Fasten the sheet steel lid and the draft diverter on the top flue outlet. Put on the top lid
Connection of the flue
Please be aware when connecting the 150 mm flue to the smoke dome that the flue is placed inside the flue outlet collar. Use stove cement in the joints. For the flue connection to the chimney, follow the recommendations from the chimney manufacturer.
Air supply
FIG 15-18: The possibility to connect a fresh air supply ducting set
(Fig Quadro Air =mm)
inserted so that the flames get established. The fire should burn with bright and lively flames.
Using the stove with low combustion effect increases pollution as well as the risk of a fire in the chimney.
Never allow the stove or flue to become glowing red. Turn off the air vent control should this happen.
Regulation of the air vent control takes some experience, but after a little while a natural rhythm for the fire will be found.
IMPORTANT! Always remember to open the air vent control (preferably also the door) when new wood logs are inserted into a hot burn chamber.
Let the flames get established on the wood before the draught is reduced.
When the draught in the chimney is low and the vents are closed, the gas from the firewood can be ignited with a bang. This can cause damages to the product as well as the immediate environment.
5. Lighting the fire for the first time
When the stove is assembled and all instructions have been observed, a fire can be lit. Be careful with touching the stove the first few times it is used as it may damage the varnish. Take care when inserting logs into the burn chamber, in order not to damage the Thermotte plates. Please note that during the first few firings, the insulations panels within the firebox will release moisture contained within them from production. This will slow down the burn rate slightly and could cause markings on the glass. These are easily removed with glass cleaner once the glass has gone cold. Possibly leave the door slightly open the first 2-3 times that the stove is used.
It is advisable to ventilate the room well when making the fire for the first time as the varnish on the stove will release
some smoke or smell. Both the smoke and smell will disappear and are not hazardous. When lighting the fire for the first time we also recommend opening/shutting the door regularly the first two hours to aviod the door gasket sticking to the varnish.
Lighting a fire
Insert small dry pieces of kindling wood, ignite and ensure that the flames have established before closing the door. Open the air vent control (Fig 6) before you close the door. Additional ignition air is obtained by leaving the door slightly open. When the flames are stable and the chimney is warm, the air supply is regulated with this air vent control so that the stove and chimney do not become overheated.
When there is a glowing layer of ash, new wood logs can be inserted. Remember to pull the hot ember forward in the burn chamber when inserting new logs so that the wood is ignited from the front. Open the vent or leave the door slightly open each time new logs are
12
GB
6. Maintenance
Cleaning and Inspection
The stove should be inspected thoroughly and cleaned at least once per season (possibly in combination with the sweeping of the chimney and chimney pipes).
Ensure that all joints are tight and that the gaskets are rightly positioned. Exchange any gaskets that are worn or deformed. Remember that the stove must always be cold when inspected.
Ashes
The ashes should be removed at regular intervals.
Be aware that the ashes can contain hot ember even several days after the fire is finished. Use a container of non-combustible material to remove the ashes. It is recommended to leave a layer of ashes in the bottom as this further insulates the burn chamber. Take care with the Thermotte plates when the ashes are removed, particularly when using an ash shovel, so as not to damage them.
Thermotte™ Plates
The insulating plates in the burn chamber (FIG 5) contribute to a high combustion temperature, which leads to cleaner combustion of the wood and a higher rate of efficiency. Any fissures in the plates will not reduce their insulation efficiency.
If new plates are needed, contact your dealer.
In case the Thermotte plates need to be replaced, lift the smoke baffle (A) in order to remove the sideplates.
A. Smoke baffle
B. Side plate
C. Back plate
D. Side plate
E. Log-stopper
F. Lower plate
Please note: Wood logs that are too long can cause strain and crack the plates, due to the tension created between the side plates.
Please also note that the Thermotte plates may release coloured dust when touched. Avoid touching any cast iron parts with dust on your fingers. Any visible dust on cast iron can be brushed off with the glove that is included.
8. Advice on lighting a fire
The best way to light a fire is with the use of lightening briquettes and dry kindling wood. Newspapers cause a lot of ash and the ink is damaging for the environment.
Advertising flyers, magazines, milk cartons and similar are not suitable for lighting a fire. Good air supply is important at ignition. When the flue is hot the draught increases and door can be closed.
Door and glass
Should there be any soot on the glass it may be necessary to clean it. Use dedicated glass cleaner.
(NB! Be careful, detergents can damage the varnish).
If different detergents are used they may damage the glass. A good advice for cleaning the glass is to use a damp cloth or kitchen roll paper and apply some ash from the burn chamber. Rub around the ash on the glass and finish off with a piece of clean and damp kitchen roll paper. NB! Only clean when the glass is cold. Check regularly that the transition between the glass and the door is completely tight. Possibly tighten the screws that hold the glass in place - but not too hard, as this can cause the glass to crack. Periodically, it may be necessary to change the gaskets on the door to ensure that the burn chamber is air tight and working optimally. These gaskets can be bought as a set including ceramic glue.
CERAMIC GLASS
CANNOT BE
RECYCLED
Warning: NEVER use a lighting fuel such as petrol, karosine, alcohol or similar for lighting a fire. This could cause injury to you as well as damaging the product.
Use clean and dry wood with a maximum moisture content of 20%. The wood should be dried for a minimum of 6 months after it is cut. Humid wood requires a lot of air for the combustion, as extra energy/ heat is required for drying the humid wood and the heat effect is therefore minimal. This in addition creates soot in the chimney with the risk of creosote and chimney fire.
Storing of wood
In order to ensure that the wood is dry, the tree should be cut in winter and stored during the summer, covered and in a location with adequate ventilation. The wood pile must never be covered by a tarpaulin lying against the ground as the tarpaulin will then act as a sealed lid that will prevent the wood from drying. Always keep a small amount of wood indoors for a few days before use so that moisture in the surface of the wood can evaporate.
Ceramic glass should be disposed of as residual waste, together with pottery and porcelain
Recycling of the ceramic glass
Ceramic glass cannot be recycled. Old glass, breakage or otherwise unusable ceramic glass, must be discarded as residual waste. Ceramic glass has a higher melting temperature, and can therefore not be recycled together with glass. In case it would be mixed with ordinary glass, it would damage the raw material and could, in worst case end the recycling of glass. It is an important contribution to the environment to ensure that ceramic glass does not end up with the recycling of ordinary glass.
Packaging recycle
The packaging accompanying the product should be recycled according to national regulations.
Usage
Not enough air to the combustion may cause the glass to soot. Hence, supply the fire with air just after the wood is added, so that the flames and gases in the combustion chamber are properly burnt. Open the air vent and have the door slightly ajar in order for the flames to establish properly on the wood.
Note that the air supply for the combustion also can be too large and cause an uncontrollable fire that very quickly heats up the whole combustion chamber to an extremely high temperature (when using with a closed or nearly closed door). For this reason you should never fill the combustion chamber completely with wood.
It is recommended to keep an even fire with a small amount of wood. Too many logs put on hot ember, may result in combustion air starvation, and the gases will be released unburnt. For this reason it is important to increase the air supply just after adding logs.
7. Warranty
For detailed description of the warranty conditions see the enclosed warranty card or visit our website www.nordpeis.com
Choice of fuel
All types of wood, such as birch, beech, oak, elm, ash and fruit trees, can be used as fuel in the insert. Wood species have different degrees of density - the more dense the wood is, the higher the energy value. Beech,
GB
13
oak and birch has the highest density.
Attention! We do not recommend using fuel briquettes/ compact wood in our products. Use of such fuel may cause the product to overheat and exceed the temperatures determined safe.
Burning briquettes/ compact wood is done so at your own risk and only small amounts (max 1/3 of normal load) should be used for each load.
Warning:
NEVER use impregnated wood, painted wood, plywood, chipboard, rubbish, milk cartons, printed material or similar. If any of these items are used as fuel the warranty is invalid.
Common to these materials is that during combustion they can form hydrochloric acid and heavy metals that are harmful to the environment, yourself and the insert.
Hydrochloric acid can also corrode the steel in the chimney or masonry in a masonry chimney.
Also, avoid burning with bark, sawdust or other extremely fine wood, apart from when lighting a fire. This form of fuel can easily cause a flashover that can lead to temperatures that are too high.
Warning:
Make sure the insert is not overheated - it can cause irreparable damage to the product. Such damage is not covered by the warranty.
Source “Håndbok, effektiv og miljøvennlig vedfyring” by Edvard
Karlsvik SINTEF Energy Research AS and Heikki Oravainen, VTT.
http//www.eufirewood.info
14
GB
Some advice in case of combustion problems
Error
No draught
Explanation
The chimney is blocked
The flue is sooty or there is accumulated soot on the smoke baffle
The smoke baffle is wrongly positioned
Downdraught in the room caused by no draught, that the house is too “air tight”.
Downdraught in the room – caused by extractor and/or central ventilation system that pulls too much air out of the room.
The flues from two fireplaces/stoves are connected to the same chimney at the same height.
The flue is in a declining position from the smoke dome to the chimney.
Solution
Contact a chimney sweeper / dealer for more information or clean the flue, smoke baffle and burn chamber.
Verify the assembly of the smoke baffle - see assembly instructions.
Light the fire with an open window. If this helps, more/bigger vents must be installed in the room.
Turn off/regulate extractor and/or other ventilation. If this helps, more vents must be installed.
One flue must be repositioned. The height difference of the two flue pipes must be of at least 30 cm.
The flue must be moved so that there is an inclination of at least 10º from smoke dome to chimney. Possibly install a smoke suction device*.
The stove release smoke when lighting the fire and during combustion
The stove releases smoke inside when it is windy outside.
The chimney is too low in relationship to the surrounding terrain, buildings, trees etc.
Turbulence around the chimney due to the roof being too flat.
The stove does not heat sufficiently.
Too much draught
The glass is sooty
The fireplace combustion receives too much oxygen due to a leakage under the lower border of the stove or too strong chimney draught. Difficult to regulate the combustion and the wood burn up too quickly.
The smoke buffer is wrongly positioned.
In case of using oven-dried wood, this requires less air supply than when using normal wood.
The gaskets around the door are worn and totally flat.
The chimney is too large.
The wood is too wet.
The air vent control is closed too tightly.
White glass
The flue is too far into the chimney.
Soot hatch in the basement or attic that is open and thus creating a false draught.
Damper/top draught vents or doors on fireplaces that are not in use are open and create a false draught.
An open hole in the chimney after that a fireplace has been removed, thus creating a false draught.
Defect masonry in the chimney, e.g. it is not airtight around the flue pipe entry and/or broken partition inside the chimney creating a false draught.
The cross-section in the chimney is too large which results in no or very low draught.
The cross-section in the chimney is too small and the chimney cannot carry out all the smoke.
The chimney is too low and hence a poor draught.
The flue must be reconnected so that it does not enter into the chimney but ends 5 mm before the chimney inner wall. Possibly install a smoke suction device*.
Soot hatches must always be closed. Hatches that are not tight or are defected must be changed.
Close damper, doors and top draught vents on fireplaces that are not in use.
Holes must be completely sealed off with masonry.
Seal and plaster all cracks and sites that are not tight.
The chimney must be refitted, possibly install a smoke suction device*.
Change to a smaller fireplace or build new chimney with a larger cross section. Possibly install a smoke suction device*.
Increase the height of the chimney and/or install a chimney cap/smoke suction device*.
Increase the height of the chimney and/or install a chimney cap/smoke suction device*.
Increase the height of the chimney and/or install a chimney cap/smoke suction device*.
Bad combustion (the temperature is too low)
Using wrong material for combustion (such as: painted or impregnated wood, plastic laminate, plywood etc)
Any possible leakage must be sealed off. A draught regulator or possibly a damper can reduce the chimney draught. NB! A leakage of only 5 cm2 is enough for 30% of the heated air to disappear.
Verify the positioning of the smoke buffer – see assembly instructions.
Turn down the air supply.
Replace the gaskets, contact your dealer.
Contact chimneysweeper or other professional for more details.
Only use dry wood with a humidity of maximum 20%.
Open the air vent control to add air to the combustion. When new wood logs are inserted all vent controls should be completely opened or the door slightly opened until the flames have a good take on the wood.
Follow the guidelines in this user guide for correct combustion.
Ensure to use only dry and clean wood.
Smoke is released when the door is opened
White smoke
Black or grey/ black smoke
A levelling out of pressure occurs in the burn chamber.
Open the air vent control for about 1 min before opening the door – avoid opening the door too quickly.
The door is opened when there is a fire in the burn chamber.
The combustion temperature is too low.
The wood is humid and contains water damp.
Open the door carefully and/or only when there is hot ember.
Increase the air supply.
Ensure to use only dry and clean wood.
Insufficient combustion.
Increase the air supply.
GB
*Electric top chimney fan
15
Quadro 1 = mm
150
440
185
34
440
Quadro 2 = mm
105
385
150
385
545
620
545
440
505
440
Quadro 3= mm
105
385
150
385
545
440
35
Quadro Air
Quadro 1 Quadro 2 Quadro 3
36
309
18
280
200
29
109,5
162
109,5
162
280
FIG 1 = mm
=Brannmur/Brandmur/Palomuuri/Firewall
=Brennbart materiale/Brændbart materiale/ Brännbart material/ Tulenarka materiaali/Combustible material
*m/isolert røykrør
*m/isolerat rökrör
*m/isoleret røgrør
*with insulated smokepipe
*Isoliertes Rauchrohr
*conduit de fumèe isolè
*Kun käytetään eristettyä savupiippua.
Huomioi savupiipun suojaetäisyys.
>550
>200/150*
>200
>8
00
50
>5
>1
50
>785
>250
>985
>50
>1
50
>535
>550
>1015/ 945*
>20
0/1
50*
37
FIG 3
FIG 4
FIG 5 FIG 6
38
F
FIG 7 FIG 8
FIG 9
FIG 10
39
40
FIG 11 FIG 12
FIG 13 FIG 14
FIG 15
FIG 16
FIG 17 FIG 18
41
42
42
FIG 19
NO
43
44
Nordpeis AS, Gjellebekkstubben 11, N-3420 Lierskogen, Norway www.nordpeis.no
NO
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project