APOLLO
Gate Operators, Inc.
Model 7200ETL
Post Mounted Residential & Heavy Duty Commercial
Slide Gate Operator
INSTALLATION MANUAL
03/07
CONTENTS
IMPORTANT SAFETY INSTRUCTIONS ........................................................ 3
Applications .................................................................................................... 4
Pre-Installation Checklist ................................................................................ 5
Parts Identification .......................................................................................... 6
Operator Installation ........................................................................................ 7
Chain Bracket Installation ............................................................................... 8
Chain & Chain Bolt Installation ....................................................................... 8-9
Chain Magnets Installation .............................................................................. 9
Gate Limit Switch Installation .……………………………………………………. 10
Quick Release Operation .................................................................................. 11
Programming Current Sensing …………………………………………………… 12
835/836 Control Board .. .................................................................................. 13-17
Siren Connection …………………………………………………………………… 18
Radio Receiver Options ……………………………………………………………. 19
Warranty ........................................................................................................... 20
2
IMPORTANT SAFETY INSTRUCTIONS
WARNING - To reduce the risk of injury or death:
• READ AND FOLLOW ALL INSTRUCTIONS.
• Installation should be performed by a professional installer.
• Required welding should be performed by a qualified welder.
• Should electricity be required, use a certified electrician only.
• Any device that requires 120 Volts AC should be U.L. approved.
• Review with the owner all safety concerns including:
⇒
⇒
Do not operate the gate unless area around gate is in full view.
Never let children operate or play with gate controls. Keep the remote control
⇒
⇒
away from children.
Always keep people and objects away from the gate. NO ONE SHOULD CROSS
THE PATH OF THE MOVING GATE.
Periodically test the obstruction sensitivity to assure safe and proper
⇒
⇒
⇒
operation. Do not test sensitivity by standing between the gate and the hinge or
stop post.
The “CAUTION AUTOMATIC GATE” signs should be clearly visible from both sides of the gate.
Always insure that the gate has closed securely before leaving area.
Arrange with local fire and law enforcement for emergency access.
• Use the emergency release only when the gate is not moving.
• Use safety devices such as loop detectors, edge switches, and beam detectors
whenever possible.
• Install control devices such as keypads far enough away (5 feet or further) from any
moving parts of the operator and gate to prevent possible injury.
• Do not install control box where the gate can come in contact with person using the
push button on side of control box.
• Always disconnect the battery or power source when making adjustments or repairs to
any part of the gate or operator.
• All rollers should be covered to prevent injury.
• KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual. Have a qualified
service person make repairs to gate hardware.
• The entrance is for vehicles only. Pedestrians must use separate entrance.
Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or stop when an object activates the non contact sensors. After adjusting the force or limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of injury or death.
SAVE THESE INSTRUCTIONS.
3
APPLICATIONS
The Apollo Model 7200ETL Slide Gate Operator is designed to handle a slide gate up to 32 feet in total length (accomodates a 30 foot drive) and 1,000 Lbs. A professional fence or gate dealer is recommended to assure proper installation.
Apollo Gate Operators are available only through qualified dealers with an outstanding reputation in the fence and gate industry. These dealers will be able to recommend the proper equipment for particular applications. Apollo Gate
Operators are 12 Volt DC (Direct Current) powered. A 12 Volt sealed battery (33 ampere hour minimum) is recommended. There are several advantages with 12 Volt
DC systems:
•
Low voltage virtually eliminates risk of electrical shock.
•
Battery powered operators provide up to 200 operations in the event of power outages.
•
The battery may be recharged with a trickle charger or by solar energy
(eliminating the need for costly trenching to remote entrances).
If a trickle charger is used and a standard electrical outlet is not readily available, a licensed electrician will be required for proper electrical hook up.
The following table should be used as a guide for capacity of operation of operators only, additional options may reduce the the daily usage. Please note that the charge
capability of solar panels will vary with different geographical locations.
Daily Cycles 1-10 1-20 1-40 1-60 1-80 80+
5 watt solar panel
10 watt solar panel
20 watt solar panel (requires 5310 regulator)
30 watt solar panel (requires 5310 regulator)
40 watt solar panel (requires 5310 regulator)
1.5 amp battery charger
10 amp battery charger
*
*
*
*
*
*
*
Note: Double the amount of solar panels for Dual Gate Operators.
4
PRE-INSTALLATION CHECKLIST
The following checklist should be used before beginning installation:
Verify that the proper operator has been selected for this application.
Verify proper installation and operation of the gate.
1. Are all rollers covered with a protective housing?
2. Are the rollers servicable?
3. Does the gate roll free and level?
4. Will the gate require a locking device?
5. Are the main posts sturdy enough to handle the gate & operator?
Determine the general location of the operator, chian brackets, and solar panel (if used).
1. Is there a suitable location for the operator?
2.Can the solar panel (if used) be mounted in an unobstructed area facing
south?
3. Will additional solar panel cable be required?
4. Is electricity available (if required)?
Consider safety and access options. Recommend if needed.
1. Will there be chidren or animals in the area?
2. Are safety loops, edge switches, or photo beam detectors required?
3. How can the gate be opened in emergencies?
4. How will visitors enter and exit?
5. Will vehicles (and trailers) have sufficient room off roadway to operate any
control devices such as keypads?
5
PARTS IDENTIFICATION
Chain Brackets (2)
5/16 Washers, Lock Washers, &
Nuts (16 each)
Operator
Chain Bolts with hardware (2 each)
Magnetic Chain Limits with hardware (2 each)
5/16” x 2” U Bolts (4 each)
5/16” x 3” U Bolts (4 each)
Master Chain Links (2 each)
Tie Wraps (4 each)
#40 Roller Chain (35 feet)
#201
5 Watt Solar Panel & Bracket
(optional)
#404C
Automatic Battery Charger (optional)
6
#273G
CAUTION Signs (2 each)
OPERATOR INSTALLATION
STEP 1. Install two 3” dia. Posts parallel to the gate as shown. Posts height depends on height preference of operator.
Gate
D r i v e w a y
F e n c e
5”
6”
24”
Inside posts
STEP 2. Remove chain cover and front lid. Mount to posts using the four supplied 3” U-bolts
7
STEP 3. Install one of the gate brackets and chain bolts on right side of gate using the supplied
2” U-bolts. Do not tighten at this time.
STEP 4. Attach the chain to the chain bolt using the master chain link.
Adjust the chain bolt to allow for maximum tightening
Note: The height of the chain bolt should align with the bottom teeth of the idler sprockets.
8
STEP 5. Thread chain on the sprockets as shown.
Chain should be level with about a 1 inch lag per 10 feet.
T O P
Chain should be aligned with all sprockets.
STEP 6. (Refer to page 8)
Install the other gate bracket and chain bolt on the left side of the gate.
Determine the required length of chain needed to attach to the chain bolt and still allow adjustment.
Using a chain breaking tool (not provided), remove excess chain.
Attach chain to chain bolt.
Tighten all chain brackets and chain bolts. Allow 1 inch of chain lag per 10 feet of chain.
9
GATE LIMIT SWITCH INSTALLATION
Align each magnet with the corresponding switch on the operator for the open and closed position.
Connect the battery and test for proper open & close position.
WARNING : If further adjustment is required, always disconnect battery prior to relocating the chain magnet.
Left or Right Hand Operation
Apollo’s line of slide gate operators are pre-wired to open the gate to the right and close the gate to the left (looking from the inside of the property).
If the operator is to be installed on the left side of the drive, use wiring diagram B
B
L
A
C
K
R
E
D
R
E
D
B
L
A
C
K K
B
L
A
C
R
E
D
Factory Hookup
B
L
A
C
K
R
E
D
R
E
D
B
L
A
C
K K
B
L
A
C
R
E
D
R
E
D
B
L
A
C
K
A
N
O
R
G
E
E
E
G
R
N
I
T
W
H
E
B
L
A
C
K
R
E
D I
T
W
H
E
E
E
G
R
N
A
N
O
R
G
E
A B
Gate in closed position operator
Gate in closed position operator
10
QUICK RELEASE OPERATION
Engaged
Engaged
11
Pull & turn 1/2 inch to disengage
STEP 7 Programming Current Sensing
The 835/836 control boards incorporate a safety feature that will put the operator into a hard shutdown mode if the control board detects a current sense two consecutive times during a cycle. This hard shutdown condition can only be reset by shorting the FIREBOX or UL connectors on the left side of the control board to ground. This condition may also be reset by pressing the
HARD SHUTDOWN RESET button located toward the upper right hand corner of the control board. If a firebox is used in the installation, The firebox door (optional) should be opened and closed to reset the control board.
The following instructions must be followed at installation for proper safety assurance.
All limits should be set before beginning this procedure.
This new procedure applies to revision 31 or higher firmware.
1. Press and hold the LED ENABLE button for five seconds. The STOP LED will blink
indicating that the board is in learn mode.
3. Cycle gate for 3 full cycles. The STOP LED will stop blinking indicating that the board
is now ready for normal operation
4. Test the auto reverse sensitivity to ensure maximum safety protection. The current
sensitivity adjustment pot may be adjusted to decrease or increase sensitivity.
COUNTER CLOCKWISE
More sensitivity
Gate is easy to current sense
CLOCKWISE
Less sensitivity
Gate is harder to current sense
8. Refer to the 835/836 Operator Control Board Manual to set other options such as
program switch options and close timer adjustments.
Installation is now complete.
Note: Program switch #9 is no longer functional and the current sense may be readjusted at any time.
12
835/836 Control Board Parts Identification
Program Switches
Timer To Close -
Dual Gate Delay -
Current Sensitivity -
Adjustments
Microprocessor
GateLink Connector
Hard Shutdown Reset
Operate Push Button
Remote Monitor Outputs
Optional Device Inputs
LED Enable & Learn
Mode Push Button
Stop Circuit Jumper
Control Board Reset
Fire & ETL Inputs
Optional Device Input
Emergency Bypass
Actuator Connector
(Slave)
Reverse Battery Polarity
Indicators
13
Actuator Connector
(Master)
1
3
5
7
2
4
6
8
Actuator Connector
Board Actuator
Cable
Pin 1 Orange
Pin 2 White
Pin 3 Black
Pin 4 Red
Pin 5 Green
Pin 6 Yellow
Pin 7 Black
Pin 8 Red
Function
Open Limit
Close Limit
Motor (positive on open, negative on close)
Motor (negative on open, positive on close)
Common for both limit switches
Feedback from intelligent actuator (816E/816EX)
Battery Negative
Battery Positive
EMERGENCY BYPASS (open only)
Applies battery voltage directly to motor to open gate if control board fails. User must unplug before gate opens to maximum travel or 15 amp fuse will open. Fuse should be checked before returning gate to service.
Remote Outputs
12V Supplied battery voltage
SLV Slave Operator Indicator (indicates slave side of gate is closed)
+12V when on closed limit. Ground when off of closed limit.
MAS Master Operator Indicator (indicates master side of gate is closed)
+12V when on closed limit. Ground when off of closed limit.
GND Battery supplied ground
SIREN Connect to siren + applies +12V when gate(s) are running, or in hard shutdown
GND Battery supplied ground
LOCK Connect to lock + (optional) Magnetic or Solenoid type locks (Dip Switch #6 Selectable)
GateLink
Connector
Connects control board to a computer using
GateLink
software. This software can monitor and diagnose the functions of the microprocessor. Ask your salesperson about this feature.
14
Adjustments
TIMER TO CLOSE Adjusts time before gate automatically closes
Adjustable 5 to 70 seconds.
DUAL GATE DELAY Adjusts delay between master and slave operation 0-4 seconds (836 only for use with magnetic, solenoid, and other locking de
vices)
CURRENT SENSITIVITY Increases or decreases the Auto Reverse
sensitivity.
Push Buttons
OPERATE When depressed, activates the gate. Used for initial
installation
Hard Shutdown Reset Resets the operator when the gate current senses twice before fully opening or closing.
LED ENABLE When depressed, activates LEDs for 15 minutes to assist in installation and troubleshooting.
Hold the push button down for five seconds to put the board in program mode.
RESET Resets the microprocessor. Returns processor to
last
Jumpers
STOP CIRCUIT JUMPER
When the STOP CIRCUIT program switch #5 must be ON JUMPER is connected, the gate
will
STOP CIRCUIT JUMPER
When a 3-button station is conprogram switch #5 must be OFF nected to the board, the STOP moved.
15
Program Switches
OFF ON
1 TIMER TO CLOSE Gate does not automatically close.
2 TIMER TO CLOSE OPT. Gate automatically closes from
Gate automatically closes.
Gate automatically closes only when completely
3 SLAVE DISABLE any position after opening.
Enables slave side (dual gate use). open (open limit engaged).
Disables slave side. (single gate use)
4 SIREN DELAY
5 ‘STOP’ CIRCUIT ENABLE Must hold down open or close
Siren (optional) active when gate is moving. buttons to move gate. Gate stops
Siren (optional) starts 5 seconds before gate moves.
Normal operation
Momentary open or close input runs gate to limit.
6 LOCK TYPE
when released.
For 12V mechanical (solenoid) locks. For 12V magnetic locks.
(+12V for 4 seconds on open cycle) (+12V when on close limit)
7 COAST ENABLE
8 FREE EXIT OPT.
Gate will stop immediately when at
Open or Close limit
A free exit input will open gate from closed position or after a close cycle only.
Gate will coast (minimally) when it reaches limits.
Recommended for 7500 slide operator only.
A free exit input will open gate from any position after an open or close cycle.
9 DUAL GATE SYNC
Both gates operate at normal
Speed (slave slower than
Master).
This feature will control the master gate to open or close at the same speed as the slave gate.
10 SMART ACT.
feature
Off for 416E & 416EX actuators, slide gates, 3500 or when slow down
Used for 816E & 816EX actuators only
(soft start & stop).
16
Optional Device Inputs
GND Supplied Battery Ground
INP Activate Gate (Push button activation when momentarily shorted to ground)
12V Supplied Battery Voltage (Protected with 3 Amp fuse)
GND Supplied Battery Ground
INP Activate Gate (Push button activation when momentarily shorted to ground)
12V Supplied Battery Voltage (Protected with 3 Amp fuse)
EDGE Reverse edge input. When grounded, will stop and reverse gate if closing, resets close timer if gate is open.
EDGE Reverse edge input. When grounded, will stop and reverse gate if closing, resets close timer if gate is open.
GND Supplied Battery Ground
GND Supplied Battery Ground
STOP Stop input from a 3 button station (must remove STOP CIRCUIT JUMPER) Normally closed
CLOSE Close input from a 3 button station (see program switch #5 for options)
OPEN Open input from a 3 button station (see program switch #5 for options)
GND Supplied Battery Ground
GND Supplied Battery Ground
FREE EXIT Opens gate if closed, stops and reverses gate if closing, resets close timer if gate is open.
GND Supplied Battery Ground
SHADOW Resets close timer when gate is open (also referred to as under gate loop)
GND Supplied Battery Ground
SAFETY Resets close timer if gate is open, stops and reverses if gate is closing. (Does not open a closed gate)
GND Supplied Battery Ground
FIRE When grounded, opens gate and holds gate open until released.
UL
Clears “Hard Shutdown” mode of software.
When grounded, opens gate and holds gate open until released.
Clears “Hard Shutdown” mode of software.
GND Supplied Battery Ground
INP Activate Gate (Push button activation when momentarily shorted to ground)
12V Supplied Battery Voltage (Protected with 3 Amp fuse)
17
APOLLO
Gate Operators, Inc.
911 Siren
The 911 Siren is included with all Apollo ETL Gate Operators.
Mount siren in an area that will produce maximum performance (additional wire may be required).
Connect the red wire to the SIREN connector on the Remote Monitor Output Connector block.
Connect the black wire to the GND connector on the Remote Monitor Output Connector block.
Red
Black
Set Program Switch # 4 as preferred:
ON - Upon activation, Siren will start for 5 seconds before gate(s) begin moving.
OFF - Siren and gate(s) start immediately upon activation.
18
APOLLO
Gate Operators
RECEIVER OPTIONS
Do not confuse the receiver code switches with the red program switches on the gate control board.
Never set all code switches to the same position. Transmitters must match code switches for proper operation.
If power is taken directly from battery or connected as shown below, receiver should be configured for 12VDC
Multi-Code/Digi-Code
black gray gray red
Allstar
white black red
Lift-Master*
1
2
3
4
Heddolf
black white yellow red
Linear
white/silver common n/o white/gold
* Lift-Master will require that the 12/24 jumper be set to 12 and the C/M (constant/momentary) jumper be set to C
19
APOLLO
Gate Operators, Inc.
LIMITED TWO-YEAR WARRANTY
Apollo Gate Operators are warranted against defects for a period of
24 months from the date of purchase, providing recommended installation procedures are followed. This warranty is in lieu of all other warranties expressed or implied (some states do not allow limitations on how long an implied warranty lasts, so this limitation may not apply to you) and shall be considered void if damage was due to improper installation or use, connection to improper power source, or if damage was caused by fire, flood, or lightning. The manufacturer will not be responsible for any labor charges incurred in the removal or replacement of defective parts.
In case of failure due to defective material or workmanship during the warranty period, the defective part will be repaired or replaced at the manufacturer’s option at no charge if returned freight prepaid. New or factory rebuilt replacements may be used. Replacement parts are warranted for the remaining portion of the original warranty period. The manufacturer will pay standard ground freight on the return of repaired or replaced items in warranty.
20