Latitude 8 Fuse Spec Sheet
Latitude™ 8 Fuse™
10A Crossover
Signature Features
Fitting Guide
Speech Enhancement LD
Automatically emphasizes speech signals based on the input level
Enhanced AutoPro2™
Allows clients to experience superior automatic performance with fast,
smooth transitions between 2 distinct destinations
Enhanced Feedback Management System
Offers adjustable strengths to suppress various degrees of feedback and
provide more usable gain
Smart Control (optional)
250 500 1000
2000 4000 8000 Hz
-10
0
10
20
30
40
50
60
70
80
90
100
110
120
open
opendome
dome
closed
closeddome
dome
power
powerdome
dome
109/40
Latitude 8 Fuse
A hand-held remote control providing access to volume control, program
change and more
Design Features
Articulating joint – Flexes with the natural movement of the ear canal to
reduce pressure points, creating a comfortable fit
Dual-flow™ vents – Uniquely shaped twin venting designed to provide an
open style fit for reduced occlusion and more natural sound
Secure-fit tab – Optional for clients with large ear canals, secure-fit tab offers
a secure and safe fit. Many clients can enjoy Fuse without the secure-fit tab.
Follow the instructions in the Complete Guide to Fuse for appropriate use or
removal
Latitude™ 8 Fuse™ is suitable for fitting mild
to moderately-severe hearing losses and can
fit audiogram configurations ranging from
reverse to precipitously sloping.
Additional Features
• 8 channels
• Automatic program (2 destinations) + 3 manual programs
• Omnidirectional microphone
• Noise Reduction
• AntiShock™
• MyMusic™
• Wind Noise Manager
• Data logging
unitron.com
09-030 027-5419-02
500
1000
2000
5000
10000
Hz
2000
5000
10000
Hz
10000
Hz
500
500
500
1000
1000
1000
2000
2000
2000
5000
5000
5000
10000
Hz
10000
Hz
10000
Hz
Frequency Range (Hz)
(DIN 45605)
Reference Test Gain
Basic Frequency Response
(input 50 dB)
Maximum
at 1.6 kHz
Full on Gain
M4
1.0%
0.5%
0.5%
1 mA
100 h
22 dB
Battery: 10A
Source: Voltage 1.3 V
The measurements obtained with a closed configuration
using a HA-1 coupler (ANSI-3.7-1995) or occluded ear
simulator (EN 60711, coupling arrangement according to
fig. 4 in the test standard).
The hearing instrument set to linear, Omni mode with all
adaptive features disabled.
Current Drain at RTG
Typical Battery Life
Equivalent Input Noise at RTG
Total Harmonic Distortion
at 500 Hz
at 800 Hz
at 1600 Hz
EMC immunity by IEC 60118-13,
Field Strength 75/50 V/m,
Omni mode
IRIL Low/High band dB SPL
Before fitting a Fuse, it is important to establish that the patient is a suitable candidate for this type of hearing instrument. Please see the instructions in the Complete Guide to Fuse.
Domes should never be fit on patients with perforated eardrums, exposed middle ear cavities, or surgically altered ear canals. In the case of such a condition, we recommend use of a customized ear mold.
We reserve the right to change specification data without notice as improvements are introduced.
Current Drain at RTG
Typical Battery Life
Equivalent Input Noise at RTG
Total Harmonic Distortion
at 500 Hz
at 800 Hz
at 1600 Hz
EMC ratings by
ANSI C63.19-2001 EMC,
Omni/Telecoil
Test Conditions:
200
200
200
Graph shown for 31.6 mA/m at RTG
at RTF
(1 mA/m at Full On Gain)
Maximum
at RTF
50
5000
50
2000
60
60
1000
70
70
500
80
80
200
90
100
100
90
Pout
dB
0
1000
0
500
10
10
200
20
20
Pout
dB
30
40
30
40
50
50
70
60
Gain
dB
80
70
Gain
dB
90
80
Maximum
Output at 1.6 kHz
OSPL90
Induction Coil Sensitivity
N/A
N/A
200
100
90
120
110
110
100
Pout
dB
Pout
dB
IEC 118-0
Reference Test Frequency
(ANSI 1996/ANSI 2003,
31.6 mA/m)
HFA SPLITS
STS/RSETS
150-8000
27 dB
40 dB
34 dB
33 dB
109 dB
104 dB
104 dB
HFA
1.6 kHz
IEC 118-0 OES COUPLER TECHNICAL DATA
Induction Coil Sensitivity
Frequency Range (Hz)
Reference Test Gain
(ANSI 1996/ANSI 2003)
Basic Frequency Response
(input 50 dB)
Maximum
HFA
at 1.6 kHz
Full on Gain
Maximum
HFA
at 1.6 kHz
OSPL90
ANSI
IEC 118-7
Reference Test Frequency
ANSI 3.22 1996/ANSI 3.22 2003/IEC 118-7 2CC COUPLER TECHNICAL DATA
Latitude 8 Fuse
37/37
1.0%
1.0%
1.0%
1 mA
100 h
22 dB
N/A
N/A
N/A
35 dB
150-8000
50 dB
40 dB
119 dB
111 dB
1.6 kHz
Latitude 8 Fuse
Latitude™ 8 Fuse™