Qmark Catalog - Duker

Qmark Catalog - Duker
TABLE OF CONTENTS
OVERVIEW
PG 4
HAZARDOUS ENVIRONMENT
About Our Company
Look For These Icons
Benefits of Electric Heat
pg 004
pg 004
pg 004
GUX Series Explosion-Proof Heaters
QWD Series Washdown Corrosion-Resistant Heaters
ICG Series Explosion-Proof Convectors
WALL HEATERS
PG 5
CEILING HEATERS
SSAR Architectural SmartSeries®
SSHO Commercial SmartSeries®
HT Residential SmartSeries®
MCSSAR Mechanical ArtisanTM
AWH Series Architectural Heavy-Duty
CWH Series Architectural Small Wall Heaters
CWH1000 Series Commercial Fan-Forced
CWH3000 Series Commercial Fan-Forced
GFR Series Fan-Forced
QFG Series Fan-Forced
LFK Series Commercial Fan-Forced
ECP Series Euro-Style, Convection
SED Series Fan-Forced
COS-ETM Series Residential Fan-Forced, Zonal
EFQ Series Commercial Fan-Forced
pg 006
pg 007
pg 008
pg 009
pg 010
pg 012
pg 013
pg 014
pg 016
pg 017
pg 018
pg 020
pg 021
pg 022
pg 024
CDF Series Commercial Downflow
EFF Series Ceiling-Mounted Fan-Forced
QCH Series Ceiling-Mounted Fan-Forced
UNIT HEATERS
GH48R Series Garage Heaters
MWUH Series Horizontal/Downflow
MUH35 Series
MUH Series
IUH Series Industrial
CU900 Series Custom Cabinet Heaters
CUS900 Series Stock Cabinet Heaters
Finned Tube Electric Duct Heaters
Open Coil Electric Duct Heaters
MSPH Series Plenum-Rated
CHPR25 Series Plenum-Rated
2
PG 25
pg 026
pg 027
pg 028
pg 030
pg 034
pg 036
pg 040
pg 041
pg 041
pg 042
pg 044
SPECIALTY HEATERS
QTS Series Toe Space Fan-Forced
WHT500 Series Utility Well House
FDI Series Floor Drop-In
CFWF Series Counterflow Electric Wall Furnaces
CONVECTION HEATERS
KCJ Series Institutional Electric
DBA & SHA Series Architectural Sill-Height
DBSL Series Slimline Aluminum
SLQDB Series Draft Barrier
CPH & DPH Series Commercial & Decorative Pedestal
CSH Series Commercial Sill-Height
DSH Series Decorative Sill-Height
ST Series Commercial Slope-Top
PG 45
pg 0046
pg 0048
pg 0050
PG 53
pg 0054
pg 0056
pg 0058
PG 59
pg 0060
pg 0061
pg 0061
pg 0062
PG 63
pg 0064
pg 0066
pg 0074
pg 0076
pg 0080
pg 0086
pg 0091
pg 0096
TABLE OF CONTENTS
BASEBOARD HEATERS
PG 99
2500 Series Electric pg 0100
HBB Series Electric Hydronic pg 0102
QMKC Series Commerical
pg 104
CBD Series Commericalpg 0106
RADIANT HEATERS
CP Series Ceiling Panels RCC Series Cove Heaters Infrared Heaters Introduction
QHRA11 & QHRA66 Series Plug-In Infrared Heaters
QVRC44 Series Commercial Infrared Heaters
FRP/FRS Series Infrared Heaters
HRK Series Single-Element Infrared Heaters
FRR Series Plug-In Radiant Heaters
CHRR Series Plug-In Radiant Heaters
BRM Series Industrial Infrared Heaters
CRN Series Industrial Permanent Infrared Heaters
ARL Series Portable Infrared Heaters
Electric Control Panels
PORTABLE HEATERS
PG 109
pg07110
pg 0113
pg 112
pg 115
pg 115
pg 116
pg 118
pg 119
pg 120
pg 121
pg 122
pg 123
pg 123
AIR CURTAINS
Air Curtain Applications Low Profile Series Environmental Series 3-Phase Environmental Electrically Heated Single-Phase Environmental Electrically Heated 24 in. Drive-Thru Window Unit Environmental Hot Water/Steam-Heated High-Velocity Series 3-Phase High-Velocity Electrically Heated High-Velocity Hot Water/Steam-Heated Accessories & Controls CEILING FANS
Destratification Ceiling Fans Specialty Ceiling Fans Accessories THERMOSTATS & CONTROLS
PG 135
pg07136
pg07137
pg07138
pg07140
pg07141
pg07141
pg07142
pg07143
pg07144
pg07145
pg07146
PG 147
pg07148
pg07149
pg07150
PG 151
PG 125
WPC1500 Series Portable Radiant Convection pg07126
202SL Series Radiant Plug-In Under Desk pg 0126
MMHD Series Portable Fan-Forced Utility
pg 127
MCM Series Portable Fan-Forced/Radiant Utility
pg 127
QPH4A Series Portable Unit pg 128
BRH Series Contractor
pg 128
PT268 Series Portable Electric pg 129
LFH Series Portable Digital Hydronic
pg 129
FHP Series Portable Electric Hydronicpg 130
FBE Series Portable Electric Convector
pg 130
TBX Moble Warming™ Portable Electric
pg 131
MSDH Series High-Temp Electric Blower
pg 132
MEDH Series Portable Electric Blower
pg 133
Compatibility Chart Model Selection Chart Thermostats & Controls APPENDIX
pg07152
pg07153
pg07154
PG 157
Certification Descriptions Paint Policy Custom Engineered Convectors Notes
For the latest models and information, please visit our website at www.qmarkmep.com3
OVERVIEW
ABOUT|OUR COMPANY
For over 50 years, Marley Engineered Products® has built on a reputation of quality and innovation, creating
Simplified Solutions for our Complex World™. We offer high quality, reliable heating products for residential,
commercial and industrial applications throughout North America. Marley Engineered Products are among
the most specified in the construction industry.
With manufacturing operations in Bennettsville, South Carolina and administrative offices in Burr Ridge,
Illinois, Marley Engineered Products are sold through select distributors in the United States and Canada.
For excellence in heating solutions, contact your local Marley Engineered Products representative.
WHAT'S NEW|LOOK FOR THESE ICONS
MADE-TO-ORDER
Marley Engineered Products prides itself with being able to provide custom
heating solutions for a wide array of applications and spaces. Unlike most heating
manufacturers, we will work with you to meet the specifications and unique needs
of your project rather than steer you towards off-the-shelf options. Please contact
our knowledgeable team of engineers and technicians at 843.454.4328 for more
information on what Made-To-Order heating products will work for you.
ENERGY-EFFICIENT
Our heating products are designed with energy-saving technology to keep end
users comfortable while keeping energy bills low. Many of our products can maintain
temperature within 1.5 degrees of the set thermostat temperature for precision comfort
and heating. Marley Engineered Products produces electric convectors that are rated
100% efficient, as well as radiant ceiling panels that also save substantial energy by
heating people rather than all the air in a room or building.
CLIP-N-FIT
EFFICIENT
Electric heat is 100% efficient. Offers the lowest
initial installed cost. Flexibility of zonal and control
of electric heating products provides end-users
competitive operating costs.
PRACTICAL
Can be used as a stand-alone heating system or
in conjunction with a forced air system. Ideal for
remodeling projects where it is not practical to
extend ductwork or piping.
CLEAN & SAFE
The patented CLIP-N-FIT feature (US Patented No. 6172343) allows the installer
to change the wattage of the heater to a lower output without moving jumper wire.
Each heater is factory-wired for its maximum wattage. To change wattage, clip out
either jumper 1 or 2 as shown in the installation manual for desired wattage. The
CLIP-N-FIT® feature also prevents the operator from changing the wattage after
installation.
®
INVISIBLE HEAT
For customers requiring heating solutions that are concealed or inconspicuous, Marley
Engineered Products offers products that can be tailored to blend into any environment
via recessing, custom paint options or fitting within a specific environment. These items
provide an enhanced customer experience while being out of sight, and out of mind.
COMPLETE SYSTEM SOLUTION
Marley Engineered Products has an efficient and sophisticated solution for every
space from floor to ceiling whether a single-family home, multi-story office building
or expansive industrial facility. We also have a wide array of compatible thermostats,
controls and accessories for applicable heating products.
4
BENEFITS OF
ELECTRIC HEAT
Can create a healthier environment for people,
particularly those suffering from allergies. Often
times, ducts become moldy or dirty with many
forced air heating systems.
TECHNOLOGY
New technologies allow heating elements to be
integrated structurally, as well as perform primary
functions as building components in floors, walls
and ceilings.
GRID MANAGEMENT & SUPPORT
Electric heating systems with control systems
can be used by utilities to balance power supply
and demand while also providing other critical
grid management balancing services.
Information from the North American Electric Heating Industry
Coalition (NAEHIC)
WALL HEATERS
5
WALL HEATERS
PROGRAMMABLE WALL HEATER
SSAR ARCHITECTURAL SMARTSERIES®
NORTHERN WHITE
IDEAL SPACES | Bedrooms; Living/Family Rooms; Basements; Offices; Conference Rooms; Lobbies; Waiting Rooms;
Entrance Ways; Vestibules; Restaurants; Stairwells
COLORS | Northern White; Navajo White; Aluminum; Statuary Bronze
GRILLE | 19-1/4" H x 15-13/16" W x 1-3/8" D BACK BOX | 18-1/4" H x 14-3/8" W x 3-3/4" D
•
The best in contemporary design with digital touch
screen LCD thermostat (5/2-day programming)
•
Hold function maintains constant set temperature.
Use for freeze protection or vacation setting when away
•
Rugged heavy duty die cast aluminum grille, BMS
compatible – Connects to Building Management
Systems for optimum control
•
Lockout Feature – Securely maintain comfort levels
•
‘Right out of the box’ installation; fits recessed between
standard studs walls with two-piece construction
•
Energy efficiency with proportional heating that
automatically adjusts wattage output
•
•
Maintains heat within 1.5 degree of set temperature
(as compared to five degrees with conventional
bi-metal thermostats)
No ducting or plumbing needed means no heat loss
before the heat enters the room
•
Power on/off switch for added safety during
maintenance
MODELS & SPECIFICATIONS
CATALOG
NO.
UPC
VOLTS
SSAR1802
685360 156835
120
SSAR4808
685360 156750
208
SSAR4804
685360 156781
240
SSAR4807
685360 156798
277
WATTS
BTU/HR.
SHIP WT.
(LBS)
1
6,142
25
1
16,378
25
20
1
16,378
25
17.3
1
16,378
25
AMPS
PHASES
900/1800
15
1440/4800
23.1
1440/4800
1440/4800
SURFACE MOUNTING FRAME ACCESSORIES
CATALOG
NO.
UPC
DESCRIPTION
SHIP WT.
(LBS)
HTWHSM
HTWHS1
6 85360 15545 6
Surface Mounting Frame 15-3/8” W x 19-3/16” H x 3-3/4” D
4
6 85360 15548 7
1 in. Semi-Recess Mounting Frame 15-3/8” W x 19-3/16 “ H x 1” D
HTWHS2
4
6 85360 15551 7
2 in. Semi-Recess Mounting Frame 15-3/8” W x 19-3/16” H x 2” D
4
NOTE: Standard grille color is Northern White. Add W (Navajo White), AL (Aluminum) or BZ (Bronze) suffix to catalog number of both the
heater and mounting frame (ex. SSAR1802AL). Mounting Limitations: Do not install heater closer than 12 in. to the floor, 12 in. to an adjacent
wall, 36 in. to the ceiling. Do not install heater behind towel rack or door, upside down or sideways, in the floor, in the ceiling, or in closets.
6
TEMP RANGE | 40°-99°F
CFM | 100
WALL HEATERS
HIGH-OUTPUT WALL HEATER
SSHO COMMERCIAL SMARTSERIES®
AVAILABLE COLORS
Northern
White
Statuary
Bronze
Custom
Colors
Navajo
White
NORTHERN WHITE
IDEAL SPACES | Bedrooms; Living/Family Rooms; Basements; Offices; Conference Rooms; Lobbies; Waiting Rooms;
Entrance Ways; Vestibules; Restaurants; Stairwells
COLORS | Northern White; Statuary Bronze; Navajo White; Custom Colors Available*
GRILLE | 19-1/8" H x 15-3/4" W x 1-3/8" D BACK BOX | 18-1/4" H x 14-3/8" W x 4" D
TEMP RANGE | 40°-99°F
CFM | 100
•
BMS compatible – Connects to Building Management
Systems for optimum control
•
No ducting or plumbing needed means no heat loss
before the heat enters the room
•
Energy efficiency with proportional heating that
automatically adjusts wattage output
•
SmartSeries® Digital Thermostat: 5/2-day
programmability with four program periods per day
•
Maintains heat within 1.5 degree of set temperature
(as compared to five degrees with conventional
bi-metal thermostats)
•
‘Right out of the box’ - three-piece construction –
Includes back box, Element/Fan Deck and Grille
•
Hold function maintains constant set temperature. Use
for freeze protection or vacation setting when away
•
Fits recessed between standard stud walls or use
with optional surface mounting frame (ideal for block
or plaster walls)
•
Lockout Feature – Securely maintain comfort levels
•
Power on/off switch for added safety during maintenance
MODELS & SPECIFICATIONS
CATALOG
NO.
UPC
VOLTS
WATTS
AMPS
PHASES
BTU/HR.
SHIP WT.
(LBS)
SSHO4008
6 85360 15670 5
208
1800/4000
8.7/19.2
1
13,650
26
SSHO4004
6 85360 15672 9
240
1800/4000
7.5/16.7
1
13,650
26
SSHO4007
6 85360 15673 6
277
1800/4000
6.5/14.4
1
13,650
26
SURFACE MOUNTING FRAME ACCESSORIES
CATALOG
NO.
UPC
DESCRIPTION
SHIP WT.
(LBS)
HTWHSM
6 85360 15545 6
Surface Mounting Frame 15-3/8” W x 19-3/16” H x 3-3/4” D
4
HTWHS1
6 85360 15548 7
1 in. Semi-Recess Mounting Frame 15-3/8” W x 19-3/16 “ H x 1” D
4
HTWHS2
6 85360 15551 7
2 in. Semi-Recess Mounting Frame 15-3/8” W x 19-3/16” H x 2” D
4
NOTE: *See page 157 for information on custom paint colors. Add NV (Navajo White) or SB (Stat Bronze) suffix to catalog number
(ex. SSHO4008NV). Mounting Limitations: Do not install heater closer than 12 in. to the floor, 12 in. to an adjacent wall, 36 in. to the
ceiling. Do not install heater behind towel rack or door, upside down or sideways, in the floor, in the ceiling, or in closets.
For the latest models and information, please visit our website at www.qmarkmep.com
7
WALL HEATERS
PROGRAMMABLE WALL HEATER
HT RESIDENTIAL SMARTSERIES®
AVAILABLE COLORS
Northern
White
Gray
GRAY
IDEAL SPACES | Bedrooms; Living/Family Rooms; Kitchens; Bathrooms; Basements; Offices; Conference Rooms;
Hallways; Lobbies; Waiting Rooms; Entrance Ways; Vestibules
COLORS | Northern White; Gray
GRILLE | 19-9/16" H x 13-11/16" W x 1" D
BACK BOX | 17-7/16" H x 12" W x 3-3/4" D
•
Heater automatically adjusts wattage output and blower
speed for whisper-quiet operation and optimum comfort
•
SmartSeries® Digital Thermostat: 5/2-day programming
with four periods per day
•
Heating element is heavy-duty, non-glowing steel fins
brazed to steel sheathed tubular elements placed in
grid pattern that covers the entire discharge area
•
Contemporary, clean design with easy to use
LED touch screen
•
Automatic fan delay eliminates cold drafts on start-up
and discharges residual heat from the heater body
during shut down
•
Easy installation - heater is mounted prior to wiring.
Both hands are free to make field connections in
spacious compartment
MODELS & SPECIFICATIONS
CATALOG
NO.
UPC
VOLTS
WATTS
AMPS
PHASES
BTU/HR.
SHIP WT.
(LBS)
HT2024SS
6 85360 15351 3
240
250/2000
1.0/8.3
1
853/6826
20
HT1502SS
6 85360 15350 6
120
200/1500
1.6/12.5
1
682/5120
20
HT2024SSNW 6 85360 15854 9
240
250/2000
1.0/8.3
1
853/6826
27
HT1502SSNW 6 85360 15852 5
120
200/1500
1.6/12.5
1
682/5120
27
SURFACE MOUNTING FRAME ACCESSORIES
CATALOG
NO.
UPC
DESCRIPTION
SHIP WT.
(LBS)
SMHTSSW
6 85360 15631 6
Northern White Surface Mounting Frame,
14-5/8”W X 20-1/4”H X 3-3/4”
2.6
SMHTSSBL
6 85360 15630 9
Black Surface Mounting Frame,
14-5/8”W X 20-1/4”H X 3-3/4”D
2.6
NOTE: Mounting Limitations: Do not install heater closer than 12 in. to the floor, 12 in. to an adjacent wall, 36 in. to the ceiling. Do not
install heater behind towel rack or door, upside down or sideways, in the floor, in the ceiling, or in closets.
8
TEMP RANGE | 40°-99°F
CFM | 100
WALL HEATERS
ARCHITECTURAL HEAVY-DUTY WALL HEATER
MCSSAR MECHANICAL ARTISAN™
BRONZE
IDEAL SPACES | Bedrooms; Living/Family Rooms; Basements; Offices; Conference Rooms; Lobbies; Waiting Rooms;
Entrance Ways; Vestibules; Restaurants; Stairwells
COLORS | Northern White; Navajo White; Statuary Bronze; Aluminum
GRILLE | 19-1/4" H x 15-13/16" W x 1-3/8" D BACK BOX | 18-1/4" H x 14-3/8" W x 3-3/4" D
•
Contemporary, yet functional design
•
Save time and money on installation
•
Two-piece construction; includes back box,
element/fan deck/grille
•
•
TEMP RANGE | 40°-99°F
CFM | 100
•
Excellent for zone heating - heat where you do need it,
not where you don’t
•
Steel-sheathed heating element combines the durability
of a steel tubular heater with the excellent heat transfer
characteristics of aluminum fins
Built-in, tamper-resistant thermostat
•
Rugged heavy-duty aluminum die-cast grille
Recess or surface mounting to wall
•
Power on/off switch for added safety during maintenance
MODELS & SPECIFICATIONS
CATALOG NO.
UPC
VOLTS
WATTS
AMPS
PHASES
BTU/HR.
SHIP WT.
(LBS)
27
MCSSAR1802
6 85360 16105 1
120
1800/900
15
1
6,142
MCSSAR4808
6 85360 16111 2
208
4000/2000
19.2
1
13,640
27
MCSSAR4804
6 85360 16109 9
240
4800/2400
20
1
16,368
27
MCSSAR4807
6 85360 16107 5
277
4800/2400
17.3
1
16,368
27
SURFACE MOUNTING FRAME ACCESSORIES
CATALOG
NO.
UPC
DESCRIPTION
SHIP WT.
(LBS)
HTWHSM
6 85360 15545 6
Surface Mounting Frame 16-1/4” W x 19-3/8” H x 3-7/8” D
4
HTWHS1
6 85360 15548 7
1 in. Semi-Recess Mounting Frame 16-1/4” W x 19-3/8” H x 1” D
4
HTWHS2
6 85360 15551 7
2 in. Semi-Recess Mounting Frame 16-1/4” W x 19-3/8” H x 2” D
4
MCAR2
6 85360 16160 0
24V Time-delay relay rated 30A @ 120 - 277V
2
MCAR12
6 85360 16159 4
120V Time-delay relay rated 30A @ 120 - 277V
2
NOTE: Standard grille color is Northern White. Add W (Navajo White), AL (Aluminum) or BZ (Bronze) suffix to catalog number (ex. MCSSAR4808BZ). Allow two weeks delivery for models with special color.
Mounting Limitations: For wall mounting, do not install back box closer than 8 in. from floor or adjacent wall. Do not install heater behind towel rack, behind door, in floor, in closet, in ceiling or where air flow
may be obstructed. All controls are concealed behind the front cover making them essentially tamper proof. They will accommodate pneumatic/electric or low-voltage controls commonly used with computerized
energy management systems.
For the latest models and information, please visit our website at www.qmarkmep.com
9
WALL HEATERS
ARCHITECTURAL HEAVY-DUTY
WALL HEATER
AWH SERIES
AVAILABLE COLORS
Northern
White
Statuary
Bronze
BRONZE & NORTHERN WHITE
IDEAL SPACES | Vestibules; Entrance Ways; Lobbies; Hallways; Stairwells; Restaurants; Conference Rooms; Offices;
Basements; Family Rooms
COLORS | Northern White; Statuary Bronze
GRILLE | 19-5/16" H x 15-3/4" W x 1-1/4" D BACK BOX | 18-1/4” H x 14-3/8” W x 3-7/8” D
10
•
BMS-compatible through an optional relay
•
Contemporary bar-stock grille designed to provide
optimized airflow
•
Manual reset thermal overheat protector disconnects
power in the event of accidental blockage
•
Built in tamper-resistant thermostat
TEMP RANGE | 40°-90°F
CFM | 100
•
All units have a permanently lubricated and enclosed
fan motor, which creates long life, low maintenance,
and gently distributes warmth throughout the area
•
Automatic fan delay eliminates cold drafts on start-up
and discharges residual heat from the heater body
during shut down
•
Power on/off switch for added safety during maintenance
WALL HEATERS
MODELS & SPECIFICATIONS
UPC
VOLTS
WATTS
AMPS
PHASES
BTU/HR.
SHIP WT. (LBS.)
AWH3150F
AWH3180F
AWH4408F
CATALOG NO.
6 85360 16186 0
6 85360 16188 4
6 85360 16210 2
AWH4407F
6 85360 16206 5
AWH4307F
AWH4303F
AWH4306F
AWH4506F
AWH4508F
6 85360 16194 5
6 85360 16402 1
6 85360 16406 9
6 85360 16414 4
6 85360 16230 0
AWH4504F
6 85360 16218 8
AWH4507F
6 85360 16226 3
AWH4503F
AWH44083F
AWH45083F
AWH44043F
AWH45043F
6 85360 16410 6
6 85360 16214 0
6 85360 16222 5
6 85360 16202 7
6 85360 16234 8
12.5
15
19.2 / 9.6
16.7/8.3
14.4 / 7.2
14.4 / 7.2
12.5/6.3
10.8 / 5.4
8.6
5
8
23.1
20
17.3
17.3
15
13.8
11.1
13.3
9.6
11.6
5118
6142
13,649/6824
13,649/6824
10,236/5118
13,649/6824
10,236/5118
10,236/5118
10,236
10,236
16,378
16,378
16,378
12,284
16,378
12,284
16,378
13,649
16,378
13,649
16,378
25
25
25
6 85360 16198 3
1500
1800
4000/2000
4000/2000
3000/1500
4000/2000
3000/1500
3000/1500
3000
3000
4800
4800
4800
3600
4800
3600
4800
4000
4800
4000
4800
1
1
1
AWH4404F
120
120
208
240
208
277
240
277
347
600
600
208
240
208
277
240
347
208
208
240
240
1
1
1
1
1
1
1
1
1
1
3
3
3
3
25
25
25
25
25
25
25
25
25
25
25
25
25
25
NOTE: *Factory-wired for higher wattage, field-convertible to half wattage. Standard finish is Statuary Bronze; For Northern White, add NW suffix to catalog number. Allow two weeks delivery for models with
Northern White finish.
ACCESSORIES
CATALOG NO.
UPC
DESCRIPTION
SHIP WT. (LBS)
AWHPE*
6 85360 00721 2
Pneumatic/Electric switch. Factory set at 10 PSIG to “make” on pressure drop. May be field
wired to “break” on pressure drop. Pressure set point adjustable to 30 PSIG. (field-installed)
2
AWHR2 (24V)*
6 85360 00723 6
AWHR12 (120V)*
6 85360 00722 9
Time delay relay 40-60 seconds to close when energized. Use 120V or 24V
power supply from remote source (field-installed)
2
AWHS1
6 85360 00726 7
1 in. deep surface mounting frame for semi-recessed installation, Statuary Bronze
2
AWHS2
6 85360 00728 1
2 in.deep surface mounting frame for semi-recessed installation, Statuary Bronze
2
AWHSM
6 85360 00724 3
Surface mounting frame for surface installations.
Painted to match heater decor, 3-13/16 in. deep, Statuary Bronze
5
LFKSFCNW
6 85360 16079 5
14-gauge security front cover, Northern White
6
NOTE: * Will accommodate pneumatic/electric or low-voltage controls commonly used with computerized energy management systems Mounting Limitations: For wall mounting, do not install back box closer
than 8 in. from floor or adjacent wall. Do not install heater behind towel rack, behind door, in floor, in closet, in ceiling or where air flow may be obstructed. All controls are concealed behind the front cover
making them essentially tamper proof.
For the latest models and information, please visit our website at www.qmarkmep.com11
WALL HEATERS
COMMERCIAL FAN-FORCED
WALL HEATER
CWH SERIES ARCHITECTURAL
SMALL WALL HEATERS
STATUARY
BRONZE
IDEAL SPACES | Vestibules; Entrance Ways; Lobbies; Hallways; Stairwells; Restaurants; Conference Rooms; Offices;
Basements; Family Rooms; Bedrooms
COLORS | Statuary Bronze
GRILLE | 12-1/8" H x 10-5/8" W x 1" D BACK BOX | 11” H x 9-1/4” W x 4” D
•
Contemporary bar-stock grille designed to provide
optimized airflow
•
•
Automatic fan delay eliminates cold drafts on start-up
and discharges residual heat from the heater body
during shut down
All units have a permanently lubricated enclosed fan
motor, which creates long life and low maintenance,
and gently distributes warmth throughout the area
•
Built-in power on/off switch for added safety during
maintenance and built in tamper-resistant thermostat
•
Manual reset thermal overheat protector disconnects
power in the event of accidental blockage
•
Tamper-proof plug for thermostat hole
MODELS & SPECIFICATIONS
CATALOG NO.
UPC
VOLTS
CWH1101DSAF
6 85360 16296 6
120
CWH1151DSAF
6 85360 16298 0
120
CWH1201DSAF
6 85360 16302 4
120
CWH1202DSAF
6 85360 16306 2
CWH1207DSAF
6 85360 16308 6
CWH1157DSAF
6 85360 16300 0
CWH1208DSAF
6 85360 16304 8
240
208
277
240
277
240
208
WATTS
AMPS
PHASES
BTU/HR
1000
500
1500
750
1800
2000
1000
1500
750
2000
1000
1500
750
1500
750
1125
562
2000
1000
8.4
4.2
12.5
6.25
15
8.4
4.2
7.3
3.61
7.3
3.61
6.25
3.2
5.5
2.75
4.7
2.35
9.6
4.8
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3413
1706
5120
2560
6143
6826
3413
5120
2560
6826
3413
5120
2560
5120
2560
3840
1920
6826
3413
SHIP WT.
(LBS)
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
ACCESSORIES
CATALOG NO.
12
TEMP RANGE | 40°-90°F
CFM | 65
NOTE: Factory-wired for higher wattage, field-convertible to half
wattage. Do not install heater closer than 4 in. from floor. Do not
install heater behind towel rack, behind door, in floor, in ceiling, in
closet, or where air flow may be obstructed.
UPC
DESCRIPTION
SHIP WT. (LBS)
CWHSMAG
6 85360 14852 6
Surface Mounting Frame (Accessory). Order separately. 12-1/2 ”H x 10-3/8” W x 4” D, Stat uary Bronze
3
CWHS1AG
6 85360 14853 3
1 in. Semi-Recess Mounting Frame, 12-1/2” H x 10-3/8” W x 1” D, Statuary Bronze
3
CWHS2AG
6 85360 14854 0
2 in. Semi-Recess Mounting Frame, 12-1/2” H x 10-3/8” W x 2” D, Statuary Bronze
3
WALL HEATERS
COMMERCIAL FAN-FORCED
WALL HEATER
CWH1000 SERIES
NORTHERN WHITE
IDEAL SPACES | Vestibules; Entrance Ways; Lobbies; Hallways; Stairwells; Restaurants; Conference Rooms; Offices;
Basements; Family Rooms; Bedrooms
COLORS | Northern White
GRILLE | 12-1/8" H x 10-5/8" W x 7/8" D
BACK BOX | 11” H x 9-1/4” W x 4” D
•
Contemporary, commercial-grade steel grille, designed
to provide comfort through optimized airflow
•
Power on/off switch for added safety during maintenance
•
Manual reset thermal overheat protector disconnects
power in the event of accidental blockage
•
Automatic fan delay eliminates cold drafts on start-up
and discharges residual heat from the heater body
during shut down
TEMP RANGE | 40°-85°F
CFM | 65
•
Integral thermostat allows for easy
adjustment of room temperature to maintain desired
comfort level
•
All units have a permanently lubricated fan motor,
which creates long life and low maintenance, and
gently distributes warmth throughout the area
•
Tamper-proof plug for thermostat hole
MODELS & SPECIFICATIONS
AMPS
PHASE
BTU/HR
SHIP WT.
(LBS.)
1000/500
8.4/4.2
1
3413/1706
12
1500/750
12.5/6.25
1
5120/2560
12
1800
15
1
6143
12
2000/1000
8.3/4.2
1
6826/3413
CATALOG NO.
UPC
VOLTS
WATTS
CWH1101DSF
6 85360 16296 6
120
CWH1151DSF
6 85360 16298 0
120
CWH1201DSF
6 85360 16302 4
120
240
208
1500/750
7.2/3.61
277
1500/750
5.5/2.75
240
1125/562
4.7/2.35
CWH1202DSF
6 85360 16306 2
CWH1157DSF
6 85360 16300 0
CWH1207DSF
6 85360 16308 6
CWH1208DSF
6 85360 16304 8
277
2000/1000
7.2/3.61
240
1500/750
6.25/3.2
208
2000/1000
9.6/4.8
5120/2560
1
5120/2560
3840/1920
1
6826/3413
5120/2560
1
6826/3413
12
12
12
12
ACCESSORIES
CATALOG NO.
UPC
DESCRIPTION
SHIP WT. (LBS)
CWHSM
6 85360 13947 0
Surface Mounting Frame. Order Separately. 12-1/2” H x 10-3/8” W x 4” D. Northern White
3
CWHS1
6 85360 13948 7
1 in. Recess Mounting Frame (Accessory) Order Separately, Northern White
3
CWHS2
6 85360 13949 4
2 in. Recess Mounting Frame (Accessory) Order Separately, Northern White
3
SRAFCTPF
6 85360 13950 0
Tamper-Resistant Front Cover, Northern White
1
For the latest models and information, please visit our website at www.qmarkmep.com
13
WALL HEATERS
COMMERCIAL FAN-FORCED WALL HEATER
CWH3000 SERIES
NORTHERN WHITE
IDEAL SPACES | Mechanical Rooms; Vestibules; Entrance Ways; Lobbies; Hallways; Stairwells; Restaurants;
Conference Rooms; Medical Offices; Basements; Family Rooms
COLORS | Northern White
GRILLE | 19-5/16" H x 15-3/4" W x 7/8" D
14
BACK BOX | 18-1/4” H x 14-5/16” W x 3-3/4” D
•
Contemporary design combined with commercial-grade
steel grille to provide comfort through optimized airflow
•
Fan-only operation for summer use
•
Built-in power on/off switch for added safety
during maintenance
•
Manual reset thermal overheat protector disconnects
power in the event of accidental blockage
TEMP RANGE | 40°-90°F
CFM | 100
•
Automatic fan delay eliminates cold drafts on start-up
and discharges residual heat from the heater body
during shut down
•
Integral double-pole thermostat allows for easy
adjustment to maintain desired temperature
•
All units have a permanently lubricated enclosed fan
motor, which creates long life, low maintenance, and
gently distributes warmth throughout the area
WALL HEATERS
MODELS & SPECIFICATIONS
CATALOG NO.
UPC
VOLTS
WATTS
AMPS
PHASE
BTU/HR
CWH3150F
6 85360 16238 6
120
1500
12.5
1
5118
25
CWH3180F
6 85360 16240 9
120
1800
15
1
6142
25
CWH3404F *
6 85360 16246 1
240
4000/2000
16.7/8.3
208
3000/1500
14.5/7.2
CWH3407F*
6 85360 16248 5
277
4000/2000
14.5/7.2
240
3000/1500
12.5/6.3
1
1
13,649/6824
10,236/5118
13,649/6824
10,236/5118
SHIP WT. (LBS)
25
25
CWH3307F*
6 85360 16242 3
277
3000/1500
10.8/5.4
1
10,236/5118
CWH3408F*
6 85360 16250 8
208
4000/2000
19.2/9.6
1
13,649/6824
25
CWH34083F
6 85360 16250 8
208
4000
11.1
3
13,649
25
CWH34043F
6 85360 16244 7
3
13,649
25
CWH3504F
6 85360 16256 0
CWH3507F
6 85360 16258 4
240
4000
9.7
240
4800
20
208
3600
17.3
277
4800
17.3
240
3600
15.0
1
1
16,378
12,284
16,378
12,284
25
25
25
CWH3508F
6 85360 16262 1
208
4800
23.1
1
16,378
25
CWH35083F
6 85360 16260 7
208
4800
13.4
3
16,378
25
CWH35043F
6 85360 16254 6
240
4800
11.6
3
16,378
25
CWH3203F
6 85360 16418 2
347
2000
5.8
1
6824
25
CWH3206F
6 85360 01909 3
600
2000
3.3
1
6824
25
CWH3153F
6 85360 16422 9
347
1500
4.3
1
5118
25
CWH3156F
6 85360 16424 3
600
1500
2.5
1
5118
25
CWH3303F
6 85360 01921 5
347
3000
8.6
1
10,236
25
CWH3306F
6 85360 01924 6
600
3000
5
1
10,236
25
CWH3403F
6 85360 01932 1
347
4000
11.5
1
13,649
25
CWH3406F
6 85360 01943 7
600
4000
6.7
1
13,649
25
CWH3503F
6 85360 01959 8
347
4800
13.8
1
16,378
25
CWH3506F
6 85360 01970 3
600
4800
8
1
16,378
25
NOTE: *Factory-wired for higher wattage, field-convertible to half wattage. For wall mounting - Do not install back box closer than 8 in. from floor or adjacent wall. Do not install heater behind towel rack, behind
door, in floor, in closet, in ceiling or where air flow may be obstructed.
ACCESSORIES
CATALOG NO.
UPC
DESCRIPTION
SHIP WT. (LBS)
FRAFCTPF
6 85360 02710 4
Tamper-Proof Front Cover, Northern White
2
CWH3SM
6 85360 02822 4
Surface Mounting Frame, Northern White
5
CWH3S1
6 85360 03036 4
1 in. Semi-Recessed Frame, Northern White
2
CWH3S2
6 85360 03035 7
2 in. Semi-Recessed Frame, Northern White
2
LFKSFCNW
6 85360 16079 5
14-gauge Security Front Cover, Northern White
6
For the latest models and information, please visit our website at www.qmarkmep.com15
WALL HEATERS
FAN-FORCED WALL HEATER
GFR SERIES
NORTHERN WHITE
IDEAL SPACES | Bedrooms; Living/Family Rooms; Kitchens; Bathrooms; Basements; Offices; Conference Rooms;
Hallways; Lobbies; Waiting Rooms
COLORS | Northern White
GRILLE | 16-7/8” W X 7-3/4” H X 7/8” D
•
•
BACK BOX | 14-3/8” W X 4-5/8” H X 4-3/8” D
TEMP RANGE | 40°-85°F
CFM | 50
Patented CLIP-N-FIT® feature allows installer to
change the desired wattage output without moving
the jumper wire
•
Tangential blower for whisper-quiet operation
•
Dual Protection: thermal cutout with indicator light and
one time thermal fuse
Contemporary register-style grille that blends with any
residential or commercial appeal
•
Permanently lubricated fan motor and dust-protected
bearings
MODELS & SPECIFICATIONS
CATALOG NO.
UPC
VOLTS
WATTS
AMPS
BUILT IN THERM
SHIP WT (LBS)
GFR1500F
6 85360 03368 6
120
1500/1125/750/375
12.5/9.4/6.3/3.1
No
10
GFR2004F
6 85360 03372 3
240*
2000/1500/1000/500
8.3/6.3/4.2/2.1
No
10
GFR2404F
6 85360 03375 4
240*
2400/1800/1200/600
10.0/7.5/5.0/2.5
No
10
GFR1500T2F
6 85360 03369 3
120
1500/1125/750/375
12.5/9.4/6.3/3.1
Double Pole
11
GFR2004T2F
6 85360 03374 7
240*
2000/1500/1000/500
8.3/6.3/4.2/2.1
Double Pole
11
GFR2404T2F
6 85360 03377 8
240*
2400/1800/1200/600
10.0/7.5/5.0/2.5
Double Pole
11
NOTE: For wall mounting only. Do not install back box closer than 4 in.from floor, 6 in. from adjacent walls and 36 in. from the ceiling. Do not install heater behind towel rack, behind door, in floor, in closet, in
ceiling or where airflow may be obstructed. To insure proper operation, maintain 5 ft. minimum clearance to furniture or other objects placed directly in front of the heater. *Will operate on 208V at 75% of rated
wattages. For installations over 7,500 ft. above sea level we recommend using models under 1500 watts. "T2F" Model are complete heater assemblies with grille, back box, and thermostat.
SUGGESTED CONTROLS
view page 151 for more options and information
TL8230A1003/U
16
M602W
ACCESSORIES
CATALOG
NO.
UPC
DESCRIPTION
SHIP WT.
(LBS)
GFRBB
6 85360 03363 1
Single Backbox For GFR Series Heater
2
GFRBB6
6 85360 03364 8
Multi-Pack Backbox (6Pcs)
10
QFGTSP
6 85360 03362 4
Single-Pole Thermostat (Field-Installed)
1
QFGTDP
6 85360 05925 9
Double-Pole Thermostat (Field-Installed)
1
GFRSM
6 85360 05926 6
Surface Mounting Frame
2
WALL HEATERS
FAN-FORCED WALL HEATER
QFG SERIES
NORTHERN WHITE
IDEAL SPACES | Bedrooms; Living/Family Rooms; Kitchens; Bathrooms; Basements; Offices; Conference Rooms;
Hallways; Lobbies; Waiting Rooms
COLORS | Northern White
GRILLE | 16-7/8” W X 7-3/4” H X 7/8” D
TEMP RANGE | 40°-85°F
CFM | 50
BACK BOX | 14-3/8” W X 6-5/8” H X 4-3/8” D
•
Patented CLIP-N-FIT® feature allows installer to change
the desired wattage output without moving the jumper wire
•
Open coil element assures instantaneous heat and
low maintenance
•
Three-piece construction for ease of installation
•
•
Tangential blower for whisper quiet operation
Dual Protection: Thermal cutout with indicator
light and one time thermal fuse
•
Northern White durable polyester powder coat finish
•
Permanently lubricated fan motor and
dust-protected bearings
•
Use multiple heaters controlled by a single thermostat
•
Use with built-in or wall-mounted thermostat
MODELS & SPECIFICATIONS
CATALOG NO.
UPC
VOLTS
WATTS
AMPS
BUILT IN THERM
SHIP WT (LBS)
QFG1512IFM
6-85360 08809 9
120
375/750/1125/1500
3.1/6.3/9.4/12.5
No
8
QFG2024IFM
6-85360 08810 5
240
500/1000/1500/2000
2.1/4.2/6.3/8.3
No
8
QFG2224IFM
6-85360 08811 2
240
563/1125/1688/2250
2.3/4.7/7.0/9.4
No
8
QFG2228IF
6-85360 05947 1
208
2200
10.6
No
8
QFG1512T2M
6-85360 05937 2
120
1500/1125/750/375
12.5/9.4/6.3/3.1
Yes
8
QFG2024T2M
6-85360 05941 9
240
2000/1500/1000/500
8.3/6.3/4.2/2.1
Yes
8
QFG2224T2M
6-85360 05946 4
240
2250/1688/1125/563
9.4/7.0/4.7/2.3
Yes
8
NOTE: *Will operate on 208V at 75% of rated wattages. “IF” models include heater assembly and grille only. Order back box separately; See accessories. For installations over 7,500 ft. above sea level we
recommend using models under 1500 watts. "T2" Model are complete heater assemblies with grille, back box, and thermostat. For wall mounting only. Do not install back box closer than 4 in.from floor, 6 in.
from adjacent walls and 36 in. from the ceiling. Do not install heater behind towel rack, behind door, in floor, in closet, in ceiling or where airflow may be obstructed. To insure proper operation, maintain 5 ft.
minimum clearance to furniture or other objects placed directly in front of the heater.
SUGGESTED CONTROLS
ACCESSORIES
CATALOG
NO.
UPC
DESCRIPTION
SHIP WT.
(LBS)
GFRBB
6 85360 03362 4
Single Backbox For Qfg Series Heater
2
GFRBB6
6 85360 03363 1
Multi-Pack Backbox (6Pcs)
10
QFGTSP
6 85360 03367 9
Single-Pole Thermostat (Field-Installed)
1
QFGTDP
6 85360 03366 2
Double-Pole Thermostat (Field-Installed)
1
GFRSM
6 85360 03364 8
Surface Mounting Frame
2
view page 151 for more options and information
For the latest models and information, please visit our website at www.qmarkmep.com
TL8230A1003/U
M602W
17
WALL HEATERS
COMMERCIAL FAN-FORCED
WALL HEATER
LFK SERIES
NORTHERN WHITE
IDEAL SPACES | Mechanical Rooms; Vestibules; Entrance Ways; Lobbies; Hallways; Hotel Stairwells; Restaurants;
Conference Rooms; Medical Offices; Basements; Living/Family Rooms
COLORS | Northern White
GRILLE | 19-5/16" H x 15-3/4" W x 1-1/4" D BACK BOX | 18-1/4” H x 14-3/8” W x 3-7/8” D
•
Contemporary commercial-grade steel grille designed
to provide a clean appearance and rugged use
•
Manual reset thermal overheat protector disconnects
power in the event of accidental blockage
•
Automatic fan delay eliminates cold drafts on start-up
and discharges residual heat from the heater body
during shut down
Integral double-pole thermostat allows for easy adjustment
•
18
TEMP RANGE | 40°-90°F
CFM | 100
of room temperature to maintain desired comfort level
•
Positive OFF switch to assure heater will not operate
if not needed
•
All units have a permanently lubricated enclosed fan
motor, which creates long life, low maintenance, and
distributes warmth throughout the area
•
Tamper-proof plug for thermostat hole
WALL HEATERS
MODELS & SPECIFICATIONS
CATALOG NO.
LFK151F
UPC
VOLTS
WATTS
AMPS
PHASE
BTU/HR
SHIP WT. (LBS.)
6 85360 16268 3
120
1500/750
12.5
1
5118/2559
22
240
2000
8.3
208
1500
7.2
1
6824
LFK204F
6 85360 16270 6
LFK303F
6 85360 16272 0
347
3000
8.6
1
10236
22
LFK304F
6 85360 16274 4
240
3000/1500
12.5
1
10,236/5118
22
5118
22
LFK306F
6 85360 16276 8
600
3000
5.0
1
10,236
22
LFK403F
6 85360 16181 5
347
4000
11.5
1
13,649
22
240
4000/2000
16.7
208
3000/1500
14.4
1
13,649/6824
LFK404F
6 85360 16179 2
LFK406F
6 85360 16278 2
600
4000
6.7
1
13,649
22
LFK408F
6 85360 16282 9
208
4000/2000
19.2
1
13,649/6824
22
LFK483F
6 85360 16280 5
347
4800
13.8
1
16,378
22
240
4800/2400
20
208
3600/1800
17.3
1
10,236/5118
16,378/8189
22
LFK484F
6 85360 16286 7
LFK486F
6 85360 16288 1
600
4800
8.0
1
16,378
22
LFK4083F
6 85360 16280 5
208
4000
11.1
3
13,649
22
LFK487F
6 85360 16290 4
277
4800/2400
17.3
240
3600/1800
15.0
1
12,284/6142
16,378/8189
12,284/6142
22
22
LFK488F
6 85360 16294 2
208
4800
23.1
1
16,378
22
LFK4883F
6 85360 16292 8
208
4800
13.3
3
16,378
23
ACCESSORIES
CATALOG NO.
UPC
DESCRIPTION
SHIP WT. (LBS)
LFKSFCNW
6 85360 16079 5
14-Gauge Security Front Cover, Northern White
6
LFKSM
6 85360 07467 2
Surface Mounting Frame For Surface Installations. 3-13/16” Deep, Northern White
1
LFKS1
6 85360 07468 9
1 in. Deep Surface Mounting Frame For Semi-Recessed Installation, Northern White
1
2 in. Deep Surface Mounting Frame For Semi-Recessed Installation, Northern White
1
LFKS2
6 85360 07469 6
For the latest models and information, please visit our website at www.qmarkmep.com19
WALL HEATERS
EURO STYLE, CONVECTION
WALL HEATER
ECP SERIES
NORTHERN
WHITE
IDEAL SPACES | Bedrooms; Living/Family Rooms; Bathrooms; Basements; Offices; Conference Rooms;
Waiting Rooms; Other Common Areas
COLORS | Northern White
GRILLE | 26-1/4” H x 16-1/4” W x 1-5/8” D
•
Ideal for instant, convection heat in supplemental
heating applications
•
Large wiring compartment is accessible from front of
heater enabling rapid, easy hookup
•
Heavy-duty metal grille offers attractive appearance
and directs air outward to effectively distribute heat
to the middle of the room
•
Dual Functional Heating - convection out the top and
radiant warmth from the front - all in one heater
•
Contemporary styling uses soft curves on all edges,
avoiding the sharp corners
•
Convection heat minimizes air flow, reducing flow
of bacteria and dust
•
Closely spaced bar grille design discourages
insertion of foreign objects
•
Steel finned metal sheath electric heating elements
provide uniform heat and long service life
•
Surface-mounted or recessed between 16 in. OC studs
MODELS & SPECIFICATIONS
CATALOG
NO.
UPC
VOLTS
WATTS
AMPS
BUILT-IN
THERM
SHIP WT.
(LBS)
ECP1024
6 85360 12732 3
240/208
1000/750
4.2/3.6
No
27
ECP1524
6 85360 12733 0
240/208
1500/1125
6.3/5.4
No
27
SUGGESTED CONTROLS
view page 151 for more options and information
TL8230A1003/U
20
BACK BOX | 23-1/8” H x 14-1/4” W x 2-22/25" D
M602W
WALL HEATERS
FAN-FORCED WALL HEATER
SED SERIES
AVAILABLE COLORS
Northern Stainless
White
Steel
NORTHERN
WHITE
IDEAL SPACES | Bedrooms; Living/Family Rooms; Kitchens; Bathrooms; Basements; Offices; Conference Rooms;
Hallways; Lobbies; Waiting Rooms
COLORS | Northern White; Stainless Steel
GRILLE | 14-1/2” H x 10-1/2” W x 1-1/4” D BACK BOX | 12-1/2” H x 9” W x 2-19/15" D
TEMP RANGE | 45°-90°F
CFM | 50
•
Ideally suited for recessed shallow wall mount
applications such as manufactured homes
•
Field wiring compartment for ease of installation
•
Fast response open coil element for instantaneous
heat and low maintenance
•
Built-in double-pole thermostat on all units
•
•
Dual Protection: Thermal cutout with indicator light
and one-time thermal fuse
Ceiling-mount units (1,000 watt units) and
surface-mount accessories available
MODELS & SPECIFICATIONS
CATALOG NO.
UPC
VOLTS
WATTS
AMPS
CEILING MOUNT
SHIP WT (LBS)
SED1012C*
6 85360 08190 8
120
1000
8.3
Yes
12
SED1024C*
6 85360 08191 5
240/208
1000/750
4.2/3.6
Yes
12
SED1512
6 85360 08192 2
120
1500
12.5
No
12
SED2024
6 85360 08193 9
240/208
2000/1500
8.3/7.2
No
12
SED1012W
6 85360 14888 5
120
1000
8.3
Yes
12
SED1024W
6 85360 15698 9
240/208
1000/750
4.2/3.6
Yes
12
NOTE: *Stainless steel models.
ACCESSORIES
CATALOG NO.
UPC
DESCRIPTION
SHIP WT. (LBS)
SEDSM
6 85360 01043 1
Northern White Surface Mounting Frame
3
SEDSMC
6 85360 12617 3
Stainless Steel Surface Mounting Frame
3
SEDFCW
6 85360 12616 6
Front Cover - Northern White
2
SEDFCC
6 85360 12615 9
Front Cover - Stainless Steel
2
For the latest models and information, please visit our website at www.qmarkmep.com
21
WALL HEATERS
RESIDENTIAL FAN-FORCED
ZONAL WALL HEATER
COS-E SERIES™
NORTHERN
WHITE
IDEAL SPACES | Bedrooms; Living/Family Rooms; Kitchens; Bathrooms; Basements; Offices; Hallways; Lobbies;
Waiting Rooms
COLORS | Northern White
GRILLE | 12” H x 9” W x 0.9" D
BACK BOX | 8-1/2” H x 6-9/25” W x 4" D
TEMP RANGE | 40°-90°F
CFM | 50
•
Patented CLIP-N-FIT® feature allows installer to change the
desired wattage output without moving the jumper wire
•
Quick installation and easy service with heater/fan
assembly fitting into back box with a single screw
•
Dual Protection: self-hold limit with one-time thermal fuse
•
Double-pole thermostat on all models
•
Dual voltage and wattage ratings help reduce
inventory levels
•
Efficient quiet operation from smooth running
multi-layer impeller
•
Contemporary look and compact size ideal for new
residential or commercial installations where space is
limited
•
Adaptable for retrofits (such as provided with
UL-approved COS-E and CS Models)*
•
Thermostat with positive OFF position for added safety
*Adaptable for retrofits into 7-7/8 in. x 11-1/2 in. x 4 in. back-box (such as provided with UL-approved COS-E and CS Models) and same rough-in opening if new box is desired.
SUGGESTED
CONTROLS
view page 151
for more information
TH106A
M601W
22
WALL HEATERS
MODELS & SPECIFICATIONS
CATALOG NO.
UPC
VOLTS (1)
VOLTS (2)
WATTS (1)
WATTS (2)
AMPS (1)
AMPS (2)
SHIP WT. (LBS)
CZ1512T
6 85360 16164 8
120
-
1500/750
-
12.5/6.3
-
11
CZ1012T
6 85360 16165 5
120
-
1000/500
-
8.4/4.2
-
8.1
CZ1048T
6 85360 16163 1
208
240
750/375
1000/500
7.2/3.6
8.4/4.2
11
CZ1548T
6 85360 16162 4
208
240
1125/570
1500/750
5.4/2.7
6.3/3.2
5.6
CZ2048T
6 85360 16161 7
208
240
1500/750
2000/1000
3.6/1.8
4.2/2.1
11
MOTOR AND GRILLE ONLY
CZ1512IF*
6 85360 16172 3
120
-
1500/750
-
12.5/6.3
-
5.7
CZ1012IF*
6 85360 16173 0
120
-
1000/500
-
8.4/4.2
-
5.7
CZ1048IF*
6 85360 16176 1
208
240
750/375
1000/500
7.2/3.6
8.4/4.2
5.6
CZ1548IF*
6 85360 16175 4
208
240
1125/570
1500/750
5.4/2.7
6.3/3.2
5.6
CZ2048IF*
6 85360 16174 7
208
240
1500/750
2000/1000
3.6/1.8
4.2/2.1
11
NOTE: *“IF” models include heater motor/assembly and grille only with no back box.
ACCESSORIES
CATALOG NO.
UPC
DESCRIPTION
SHIP WT. (LBS)
CZBB
6 85360 16333 8
Back Box Only (Used with “IF” suffix models)
2
CZBB6
6 85360 16334 5
Back Box Multi-Pack (Used with “IF” suffix models)
10.5
CZTDP
6 85360 16332 1
Double-Pole Built-in Thermostat Kit (Range: 40-85°F)
1
CZSM
6 85360 16335 2
Surface Mounting Frame
2
CZ2CRAKIT
6 85360 16519 6
Retrofit Kit CRA to COS-E
2
For the latest models and information, please visit our website at www.qmarkmep.com23
WALL HEATERS
COMMERCIAL FAN-FORCED
WALL HEATER
EFQ SERIES
NORTHERN WHITE
IDEAL SPACES | Offices; Stores; Schools; Churches; Hospitals; Dormitories; Airport Terminals; Reception Rooms; Lobbies;
Corridors; Stairwells; Conference Rooms; Hallways; Lobbies; Waiting Rooms
COLORS | Northern White
GRILLE | 31-3/4” W x 22-3/4” H x 1-1/2” D
BACK BOX | 30-1/2” W x 21-1/8” H x 3-3/4” D
•
Steel finned metal sheath electric heating elements with
low sheath temperatures provided uniform heat and long
service life
•
Rugged stamped steel front cover provides a down-flow
air pattern Integral thermostat for quick installation;
separate thermostat not necessary
TEMP RANGE | 60°-90°F
CFM | 200
•
Thermal overheat protectors disconnect power in event
of accidental blockage
•
Power on/off switch for added safety during maintenance
•
Permanently lubricated enclosed fan motor provides
long-life and low maintenance
MODELS & SPECIFICATIONS
CATALOG NO.
UPC
VOLTS
PHASE
WATTS
AMPS
BUILT-IN THERMOSTAT
SHIP WT. (LBS)
EFQ6008
6 85360 02135 5
208
1
6000
28.8
Yes
50
EFQ6004
6 8536 02131 7
240
1
6000
25
Yes
50
EFQ6007
6 8536 02134 8
277
1
6000
21.7
Yes
50
EFQ6003
6 8536 02130 0
347
1
6000
17.3
Yes
50
EFQ60048
6 8536 02132 4
480
1
6000
12.5
Yes
50
EFQ6006
6 8536 02133 1
600
1
6000
10
Yes
50
EFQ8008
6 8536 02141 6
208
1
8000
38.5
Yes
50
EFQ8004
6 8536 02137 9
240
1
8000
33.3
Yes
50
EFQ8007
6 8536 02140 9
277
1
8000
28.9
Yes
50
EFQ8003
6 8536 02136 2
347
1
8000
23.1
Yes
50
EFQ80048
6 8536 02138 6
480
1
8000
16.7
Yes
50
EFQ8006
6 8536 02139 3
600
1
8000
13.3
Yes
50
ACCESSORIES
CATALOG NO.
24
UPC
DESCRIPTION
SHIP WT. (LBS)
EFQSM
6 85360 02127 0
Surface Mounting Frame
6
EFQS1
6 85360 02128 7
1 in. Semi-Recess Frame
5
EFQS2
6 85360 02129 4
2 in. Semi-Recess Frame
6
EFQR24
6 85360 02126 3
24V Power Relay
1
EFQR120
6 85360 02125 6
120V Power Relay
1
UNIT HEATERS
25
UNIT HEATERS
GARAGE UNIT HEATER
GH48R SERIES
Remote control requires
(2) AAA batteries. Not included.
BLACK
IDEAL SPACES | Garages; Warehouses; Storage Facilities; Stockrooms; Workshops
COLORS | Black
DIMENSIONS | 17-3/4" L x 18" H x 12" D
TEMP RANGE | 45°-99° F
•
Built-in digital interface
•
Remote control included for easy operation
•
Optional timer feature; up to nine hours
with automatic shut off
•
Power indicator light
CFM | 160
•
Automatic fan delay eliminates cold drafts on start-up
and discharges residual heat from the heater body
during shut down
•
Stainless steel tubular heating element
•
Includes mounting bracket for wall or ceiling installation
MODELS & SPECIFICATIONS
CATALOG NO.
GH48R
26
UPC
VOLTS
WATTS
AMPS
BTU/HR
SHIP WT. (LBS)
6 85360 16569 1
240
208
2400/4800
1800/3600
10/20
8.6/17.3
8189/16,378
6142/12,284
13
13
UNIT HEATERS
HORIZONTAL/DOWNFLOW
UNIT HEATER | MWUH SERIES
NEUTRAL
GRAY
IDEAL SPACES | Factories; Garages; Maintenance Rooms; Warehouses; Public Buildings; Service Stations; Workshops; Stairwells
COLORS | Neutral Gray
DIMENSIONS | 14" L x 12-1/2" H x 11-1/4" D
TEMP RANGE | 45°-90° F
CFM | 270
•
Heater comes equipped with ceiling-mount bracket
for horizontal or vertical flow mounting or any position
in between
•
Automatic fan delay eliminates cold drafts on start-up
and discharges residual heat from the heater body
during shut down
•
Built-in single-pole thermostat
•
•
Copper-brazed steel fins with steel sheathed
tubular elements for uniform heating and longevity
High limit cutout automatically shuts off current in
event of overheating and reactivates unit when
temperature returns to normal
•
Adjustable louvers control air throw direction
•
Disconnect switch (DS30) option available for heaters
24 amps or lower.
MODELS & SPECIFICATIONS
CATALOG NO.
UPC
VOLTS
208
MWUH5004
6 85360 03880 3
240
208
MWUH7504
6 85360 14870 0
240
MWUH5008
6 85360 04771 3
208
WATTS
BTU/HR.
1874
2500
3123
3750
2500
3332
4165
5000
2812
3750
4685
5625
3750
5000
6250
7500
2500
3332
4165
5000
6396
8553
10659
12799
8533
11365
14215
17065
9598
12799
15990
19198
12799
17065
21331
25598
8533
11365
14215
17065
FAN
MOTOR
WATTS
CONTROL
& FAN
MOTOR
VOLTS
FAN
MOTOR
RPM
AIR
THROW
(FT.)
MIN.
MOUNTING
HEIGHT (FT)
208
6
1350
16
6
1400
18
8
1400
16
8
240
208
6
240
6
208
HEATER
AMPS
MIN. CKR.
AMPS
9.0
12.0
15.0
18.0
10.4
13.9
17.4
20.9
13.5
18.0
22.5
27.1
15.6
20.8
26.0
31.3
12.0
16.0
20.0
24.0
11.3
15.0
18.5
22.5
13.0
17.4
21.8
26.1
11.3
15.0
18.5
22.5
19.5
26.0
32.5
39.1
15.0
20.0
26.0
SHIP WT.
(LBS)
24
27
26
NOTE: Disconnect switch (DS30) option available for heaters 24 amps or lower. Optional CWB1A combination wall/ceiling bracket available.
For the latest models and information, please visit our website at www.qmarkmep.com
27
UNIT HEATERS
UNIT HEATER | MUH35 SERIES
CHARCOAL
GRAY
IDEAL SPACES | Factories; Garages; Schools; Shipping Docks; Warehouses
COLORS | Charcoal Gray
DIMENSIONS | 22" L x 16" H (14" w/o bracket) x 8" D
TEMP RANGE | 40°-90° F
CFM | 210
•
Air flow can be directed vertically, horizontally or
any position in between
•
•
Mounts either on wall or ceiling for primary or spot
heating (bracket included)
Advanced pull-through air flow design draws air
across heating element for even air distribution and
cooler element operation
•
•
Built-in bi-metal thermostat; multiple wattage heat
selector switch for precise amount of heat
Heavy gauge die-formed steel housing and completely
enclosed fan motor
•
Aluminum-finned, copper-clad steel sheath heating
Specially designed venturi outlet to meet required
additional air throw in vertical position
•
Manual reset thermal cut-off button located on front
for easy access
•
•
NEED MORE element extends life due to cooler sheath temperature
Fan-only switch for air movement when no heat is required
and faster heat dissipation
DESCRIPTIVE BULLETS
MODELS & SPECIFICATIONS
CATALOG NO.
UPC
MUH35
6 85360 04757 7
VOLTS
WATTS
BTU/HR.
AMPS
240
5000/3333
17060/11372
21.0/14.0
208
3750/2500
12795/8530
18.0/12.0
PHCS1B
28
Cord & Plug Assembly (Optional)
AIR DELIVERY DATA
28
SHIP WT. (LBS)
MAXIMUM EFFECTIVE
MOUNTING HEIGHT
FAN MOTOR DATA
CFM
FPM
∆T(°F)
VOLTS
RPM
HP
HORIZ.
VERT.
210
550
71
240/208
1600
1/100
8
15
HORIZONTAL
AIR THROW
WIRE
SIZE
24
AWG 10
UNIT HEATERS
UNIT HEATER | MUH SERIES
NEUTRAL
GRAY
IDEAL SPACES | Factories; Warehouses; Garages; Stairwells; Shipping Docks; Power Stations; Mechanical Rooms
COLORS | Neutral Gray/Statuary Bronze
DIMENSIONS | Varies (see diagram)
TEMP RANGE | 40°-90° F
CFM | 350-3000
•
Wide range of optional control kits are field-installable,
increasing the unit's adaptability to specification market
•
1- or 3-phase wiring on 5 kW through 10 kW 208/240V
and 15 kW 208V units (field-interchangeable)
•
Small- to medium-case construction is 20-gauge steel
with larger cabinet 18-gauge steel
•
•
Advanced pull-through air flow design draws air across
heating element for even air distribution and cooler
element operation
Aluminum-finned, copper-clad steel sheath heating
element extends life due to cooler sheath temperature
and faster heat dissipation
•
•
Specially designed venturi outlet to meet required
additional air throw in vertical position
24V control transformer standard on most models,
providing safer and more accurate means of
temperature control. 3 kW and 5 kW, 208-277V,
have line voltage controls as standard (24V
control available on made-to-order basis)
•
Branch circuit fusing (when required)
•
•
Completely enclosed fan motor
Automatic reset linear thermal cut-out, capillary type,
provides protection over entire length of element areas
(manual reset protection available on made-to-order basis)
•
2-speed fan selector switch (25 to 50 kW models)
•
No piping flues, valves or traps needed for installation
•
Optional fan-only switch for air movement with no heat
•
Individually adjustable louvers to direct air flow
CATALOG NO.
30
HEIGHT (IN)
WIDTH (IN)
DEPTH (IN)
MUH03 & 05
16
14
7-1/2
MUH07 & 10
21-3/4
19
7-1/2
MUH15 & 20
21-3/4
19
12-3/4
MUH25 & 30
30
26-5/8
11-3/4
MUH40 & 50
30
26-5/8
17-1/8
04721 8
04728 7
04735 5
04741 6
04745 4
04749 2
04756 0
04766 9
04716 4
04722 5
04730 0
04736 2
04742 3
04746 1
04750 8
04753 9
04760 7
04763 8
04720 1
04727 0
04734 8
04740 9
04718 8
04725 6
04732 4
04738 6
04743 0
04747 8
04751 5
04754 6
04761 4
04764 5
04717 1
04724 9
04731 7
04737 9
04719 5
04726 3
04733 1
04739 3
04744 7
04748 5
04752 2
04755 3
04762 1
04765 2
MUH0381
MUH0581*
MUH078*
MUH108*
MUH158*
MUH208*
MUH308*
MUH508*
MUH0321
MUH0521*
MUH072*
MUH102*
MUH152*
MUH202*
MUH252*
MUH302*
MUH402*
MUH502*
MUH0371
MUH0571
MUH077
MUH107
MUH0341*
MUH0541*
MUH074*
MUH104*
MUH154*
MUH204*
MUH254*
MUH304*
MUH404*
MUH504*
MUH0331
MUH0531
MUH073
MUH103
MUH0361*
MUH0561*
MUH076*
MUH106*
MUH156*
MUH206*
MUH256*
MUH306*
MUH406*
MUH506*
208
208
208
208
208
208
208
208
208/240
208/240
208/240
208/240
208/240
208/240
208/240
208/240
208/240
208/240
277
277
277
277
480
480
480
480
480
480
480
480
480
480
347
347
347
347
600
600
600
600
600
600
600
600
600
600
VOLTS
1
1-3
1-3
1-3
1-3
3
3
3
1
1-3
1-3
1-3
3
3
3
3
3
3
1
1
1
1
3
3
3
3
3
3
3
3
3
3
1
1
1
1
3
3
3
3
3
3
3
3
3
3
PHASE
3
5
7.5
10
15
20
30
50
2.2/3.0
3.7/5.0
5.6/7.5
7.5/10.0
11.2/15.0
15.0/20.0
18.7/25.0
22.5/30.0
30.0/40.0
37.5/50.0
3
5
7.5
10
3
5
7.5
10
15
20
25
30
40
50
3
5
7.5
10
3
5
7.5
10
15
20
25
30
40
50
KW
10.2
17
25.6
34.1
51.2
68.2
102.3
170.5
7.5/10.2
12.6/17.0
19.1/25.6
25.6/34.1
38.2/51.2
51.2/68.2
63.8/85.2
76.7/102.3
102.3/136.4
127.3/170.5
10.2
17
25.6
34.1
10.2
17
25.6
34.1
51.2
68.2
85.2
102.3
136.4
170.5
10.2
17
25.6
34.1
10.2
17
25.6
34.1
51.2
68.2
85.2
102.3
136.4
170.5
BTU/HR.
14.5
24
36
48
72
56
84
139
11.0/12.5
18.0/21.0
27.0/31.3
36.0/42.0
31.3/36.1
41.2/48.0
52.0/60.0
63.0/72.3
83.4/96.4
104.2/120.4
11
18
27
36
3.6
6
9
12
18
24
30
36
48
60.2
8.6
14.4
21.6
28.8
2.9
4.8
7.3
9.7
14.5
19.3
24.2
29
38.7
48.3
AMPS (3)
208
208
24
24
24
24
24
24
208/240
208/240
24
24
24
24
24
24
24
24
277
277
24
24
24
24
24
24
24
24
24
24
24
24
347
347
24
24
24
24
24
24
24
24
24
24
24
24
CONTROL
VOLT (1)
2 STAGE
ELEMENT
CONTROL
N/A
5A
5B
5B
5A
5A
5A
5A
N/A
5A
5B
5B
5C
5C
5A
5A
5A
5A
N/A
N/A
5B
5B
N/A
N/A
5B
5B
5C
5C
5C
5C
5A
5A
N/A
N/A
5B
5B
N/A
N/A
5B
5B
5C
5C
5C
5C
5A
5A
350
350
650
650
910
1320
2100/1800
3000/2600
350
350
650
650
910
1320
2100/1800
2100/1800
3000/2600
3000/2600
350
350
650
650
350
350
650
650
910
1320
2100/1800
2100/1800
3000/2600
3000/2600
350
350
650
650
350
350
650
650
910
1320
2100/1800
2100/1800
3000/2600
3000/2600
CFM (2)
800
800
970
970
1640
2060
2100/2030
3260/2900
800
800
970
970
1640
2060
2100/2030
2100/2030
3260/2900
3260/2900
800
800
970
970
800
800
970
970
1640
2060
2100/2030
2100/2030
3260/2900
3260/2900
800
800
970
970
800
800
970
970
1640
2060
2100/2030
2100/2030
3260/2900
3260/2900
FPM (2)
27°
45°
37°
49°
52°
48°
45°/53°
53°/61°
27°
45°
37°
49°
52°
48°
38°/44°
45°/53°
42°/49°
53°/61°
27°
45°
37°
49°
27°
45°
37°
49°
52°
48°
38°/44°
45°/53°
42°/49°
53°/61°
27°
45°
37°
49°
27°
45°
37°
49°
52°
48°
38°/44°
45°/53°
42°/49°
53°/61°
∆T(°F)
208
208
208
208
208
208
208
208
208/240
208/240
208/240
208/240
208/240
208/240
208/240
208/240
208/240
208/240
277
277
277
277
480
480
480
480
480
480
480
480
480
480
347
347
347
347
600
600
600
600
600
600
600
600
600
600
VOLTS
AIR DELIVERY DATA FAN MOTOR DATA
1600
1600
1600
1600
1530
1500
1600/1375
1525/1420
1600
1600
1600
1600
1530
1500
1600/1375
1600/1375
1525/1420
1525/1420
1600
1600
1600
1600
1600
1600
1600
1600
1530
1500
1600/1375
1600/1375
1525/1420
1525/1420
1600
1600
1600
1600
1600
1600
1600
1600
1530
1500
1600/1375
1600/1375
1525/1420
1525/1420
RPM (2)
1/100
1/100
1/30
1/30
1/20
1/10
1/4
1/2
1/100
1/100
1/30
1/30
1/20
1/10
1/4
1/4
1/2
1/2
1/100
1/100
1/30
1/30
1/100
1/100
1/30
1/30
1/20
1/10
1/4
1/4
1/2
1/2
1/100
1/100
1/30
1/30
1/100
1/100
1/30
1/30
1/20
1/10
1/4
1/4
1/2
1/2
HP
8
8
9
9
11
12
12
15
8
8
9
9
11
12
13
12
15
15
8
8
9
9
8
8
9
9
11
12
13
12
15
15
8
8
9
9
8
8
9
9
11
12
13
12
15
15
HORIZ.
9
9
14
14
20
23
20
25
9
9
14
14
20
23
23
20
28
25
9
9
14
14
9
9
14
14
20
23
23
20
28
25
9
9
14
14
9
9
14
14
20
23
23
20
28
25
VERT.
MOUNTING HEIGHT
12
12
18
18
35
41
50
60
12
12
18
18
35
41
50
50
60
60
12
12
18
18
12
12
18
18
35
41
50
50
60
60
12
12
18
18
12
12
18
18
35
41
50
50
60
60
HOROIZ.
THROW
AWG 12
AWG 10
AWG 6
AWG 4
AWG 2
AWG 4
AWG 1
AWG 4/0
AWG 12
AWG 10
AWG 8
AWG 6
AWG 6
AWG 4
AWG 3
AWG 2
AWG 1/0
AWG 3/0
AWG 14
AWG 10
AWG 8
AWG 6
AWG 14
AWG 14
AWG 14
AWG 14
AWG 10
AWG 10
AWG 8
AWG 6
AWG 4
AWG 4
AWG 14
AWG 10
AWG 14
AWG 14
AWG 14
AWG 10
AWG 14
AWG 14
AWG 12
AWG 12
AWG 10
AWG 8
AWG 6
AWG 3
WIRE
SIZE
SHIP WT.
(LBS.)
W/BRCKT
1
27
38
38
53
60
93
114
27
27
38
38
53
60
93
93
114
114
27­
27
38
38
27
27
38
38
53
60
93
93
114
114
27
27
38
38
27
27
38
38
53
60
93
93
114
114
NOTE: All standard units are supplied with a low voltage control transformer and contactor (24V) except MUH03 and MUH05, 208V, 240V and 277V models. Low voltage control on these units is available on made to order. All units are also available
on special order for 120V control; internal with transformer or external without transformer. On dual-voltage units CFM, FPM, & RPM ratings are listed at higher voltage operation. On dual-phase units maximum amp draw is listed for respective voltage.
25 thru 50 KW models having two-speed motors and dual CFM ratings are listed in Full Line Catalog. 5A. Standard; 5B. Optional - made to order - amp load unbalanced on three-phase; 5C. Optional - made to order - amp load balanced on threephase. *Must use two-stage Thermostat on 3Ø operation.
UPC
6-85360
CATALOG
NO.
ELECTRICAL DATA
UNIT HEATERS
MODELS & SPECIFICATIONS
For the latest models and information, please visit our website at www.qmarkmep.com31
UNIT HEATERS
OPTIONAL FIELD-INSTALLED ELECTRICAL CONTROLS
CATALOG NO.
UPC
DESCRIPTION
ELECTRICAL RATING
COMPATIBLE WITH
UHMT1
6 85360 15241 7
Single Pole Internal ThermostatTemp Range: 40°- 85°F
25A @ 120, 240VAC Res.
22A @ 277VAC Res.
All MUH Series Heaters
(except MUH0521 3 PH, MUH0581 3 PH which use UHMT2)
UHMT2
6 85360 15242 4
Two Stage Internal Thermostat-Temp
Range: 40°- 85°F
25A @ 120, 240VAC Res.
22A @ 277VAC Res. 125VA
MCFS
6 85360 04637 2
Pilot Duty 6A, 600VAC Res.
2 HP
MRFS1
6 85360 04708 9
Internal Summer Fan Switch
250, 480, 600V.A.C. 1,2 OR 3 PH
Remote Summer Fan Switch
(Line Voltage)
MUH0521 3 PH, MUH0581 3 PH, MUH158, MUH208, MUH252,
MUH302, MUH308, MUH402, MUH404, MUH406, MUH502,
MUH504, MUH506, MUH508
MRFS2
6 85360 04709 6
MHRT
All MUH Series Heaters
2 HP, 250-480VAC
All MUH Series Heaters
Remote Summer Fan Switch
with Relay (24V Coil-Single Pole
Normally Open)
6 AFL, 35 ALR, 250VAC, 60Hz
3 AFL, 18 ALR, 480VAC, 60Hz
All MUH Series Heaters
(except MUH0321, MUH0371, MUH0381,
MUH0521, MUH0571, MUH0581)
Units unless optional control transformer is supplied
6 85360 04694 5
Heat Recovery Thermostat with
Relay (24V Coil-Single Pole Normally
Open) Hi - 120°F, Low - 60°F
6 AFL, 35 ALR, 250VAC, 60Hz
3 AFL, 18 ALR, 480VAC, 60Hz
All MUH Series Heaters
(except MUH0321, MUH0371, MUH0381,
MUH0521, MUH0571, MUH0581)
Units unless optional control transformer is supplied
MPDS25
6 85360 04703 4
Power Disconnect Switch (3-Pole)
30A @ 600VAC, Res.
MUH0321, MUH0341, MUH0371, MUH0381,
MUH0521, MUH0541, MUH0571, MUH0581,
MUH073, MUH074, MUH076, MUH104, MUH106,
MUH154, MUH156, MUH204, MUH206
MPDS60
6 85360 04704 1
Power Disconnect Switch (3-Pole)
80A @ 600VAC, Res.
MUH072, MUH077, MUH078, MUH102, MUH103,
MUH107, MUH108, MUH152, MUH202, MUH208,
MUH252, MUH254, MUH256, MUH304, MUH306,
MUH404, MUH406, MUH504, MUH506
NOTE: Any field installed options assembled in the factory require added surcharge. See price book for charges. MPDS60 disconnect switch is not suitable for field installation on 7.5kw and 10kw unit heaters.
DIFFUSER SELECTOR TABLES FOR VERTICAL MOUNTING
CATALOG NO.
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
MLDS
MLDM
MLDM
MLDM
MLDL
MLDL
MLDL
MLDL
32
DESCRIPTION
WITHOUT DIFFUSER
No diffuser needed where a straight
downflow air pattern is required. For
maximum air throw, remove louvers.
Any of three diffusers can be added to
basic heater.
LOUVER DIFFUSER
Permits directional (straight line) air
flow as in air curtain application over
doorways. Rectangular coverage,
Louvers can be turned in either
direction.
CATALOG NO.
MUH03 &MUH05
MUH07 & MUH10
MUH15
MUH20
MUH25
MUH30
MUH40
MUH50
MUH03 & MUH05
MUH07 & MUH10
MUH15
MUH20
MUH25
MUH30
MUH40
MUH50
MAX. MOUNTING
HEIGHT
9
14
20
23
23
20
28
25
9
14
18
20
23
20
24
22
(A) DIMENSION
18
26
35
40
63
55
70
63
25(A)
39(A)
50(A)
56(A)
12(B)
19(B)
25(B)
28(B)
72(A)
36(B)
88(A)
80(A)
44(B)
40(B)
DIFFUSER PATTERN AND AREA
UNIT HEATERS
OPTIONAL MOUNTING BRACKETS
CATALOG NO.
B10
B20
B30
B50
UPC
COMPATIBLE WITH
SHIP WT. (LBS)
6 85360 15229 5
6 85360 15230 1
6 85360 15231 8
6 85360 15232 5
MUH03 - 10
MUH15 & 20
MUH25 & 30
MUH40 & 50
8
10
13
15
UPC
6 85360 15236 3
6 85360 15237 0
6 85360 15238 7
6 85360 15239 4
COMPATIBLE WITH
MUH03 - 10
MUH15 & 20
MUH25 & 30
MUH40 &50
SHIP WT. (LBS)
3
4
5
6
OPTIONAL VERTICAL CEILING MOUNTING BRACKETS
CATALOG NO.
VDMB5
VDMB20
VDMB50
UPC
6 85360 15245 5
6 85360 15246 2
6 85360 15247 9
COMPATIBLE WITH
MUH03 - 05
MUH07 - 20
MUH25 - 50
DESCRIPTION
MUH03 & 05 (208, 208/240, 277V Supply)
24 or 120V Control Transformer and Power Contactor
24 or 120V H.C. Power Contactor
MUH03 & 05 (480V Supply) & MUH07 thru MUH50
Optional 120V Control
OPTIONAL CEILING MOUNTING BRACKETS
CATALOG NO.
CMB10
CMB20
CMB30
CMB50
FACTORY-INSTALLED OPTIONS
FOR CONTROLS & ACCESSORIES
SHIP WT. (LBS)
5
7
9
MOUNTING LIMITATIONS: Unit heaters should not be used in potentially explosive atmospheres. The finish is
not intended for direct salt spray exposure in marine applications or the highly corrosive atmospheres of swimming
pools, chemical storage bins, etc. Do not install unit heaters above recommended maximum mounting height.
Obstructions must not block unit heater air inlet or discharge. Heaters must be mounted at least 7 ft. above the floor
to prevent accidental contact with the heating element or fan blade which could cause injury.
2-Stage Control of Elements (See Note 5)
Manual Reset
Outlet Mesh (Bird Screen) For all MUH Heaters
NOTE: Any factory-installed options require added surcharge. See price book for
charges or contact factory.
DIMENSIONS
CATALOG NO.
MUH03 & 05
MUH07 & 10
MUH15 & 20
MUH25 & 30
MUH40 & 50
HEIGHT
(IN)
16
21-3/4
21-3/4
30
30
WIDTH
(IN)
14
19
19
26-5/8
26-5/8
DEPTH
(IN)
7-1/2
7-1/2
12-3/4
11-3/4
17-1/8
BRACKET SIZE
DIMENSION
A
B
C
D
E
L
M
N
3-20 kW (IN)
7-1/4
9-1/2
7-1/4
11-5/16
2-1/4
20-1/2
9-15/16
3-1/4
25 - 50 kW (IN)
9-7/16
14-3/8
12-1/8
2-1/16
3
28-15/16
14-15/16
4-1/2
For the latest models and information, please visit our website at www.qmarkmep.com33
UNIT HEATERS
INDUSTRIAL UNIT HEATER
IUH SERIES
NEUTRAL
GRAY
IDEAL SPACES | Factories; Garages; Stores; Maintenance Room; Warehouses; Public Buildings; Service Stations;
Workshops; Stairwells
COLORS | Neutral Gray
DIMENSIONS | Varies (see specifications)
•
34
TEMP RANGE | 60°-120° F
All motors and contactor coils are 240V and operate on
the secondary of a factory-installed step-down power
transformer on 480V and 600V heaters so a separate fan
and motor control power source is not needed
•
Automatic fan delay eliminates cold drafts on start-up
and discharges residual heat from the heater body
during shut down
•
Steel fins are copper-brazed to low-watt density,
steel-sheathed tubular heating elements
•
5 and 7.5 kW models also come equipped with
ceiling mounting bracket for horizontal or vertical
flow mounting or any position in between
CFM | 270-1800
•
Uniform discharge of all heated air lowers internal
operating temperatures and prolongs element life
•
Cabinet is finished with a polyester powder coating
for excellent corrosion resistance
•
Element finished with aluminized paint for corrosion
resistance
•
Fins and elements are arranged in a uniform grid pattern
and fit closely into air discharge area to assure that all
incoming air passes through heating element
•
High-limit cut-off automatically shuts off current in
the event of overheating and reactivates unit when
temperature returns to normal
UNIT HEATERS
MODELS & SPECIFICATIONS
CATALOG
NO.
UPC
KW.
CAP.
BTU/
HR.
HTR.
VOLT
PHASE
IUH520
IUH524
IUH548
IUH560
IUH720
IUH724
IUH748
IUH760
IUH1024
IUH1048
IUH1060
IUH1524
IUH1548
IUH1560
IUH2048
IUH2060
IUH2548
IUH2560
IUH3048
IUH3060
6 85360 04196 4
6 85360 04197 1
6 85360 04202 2
6 85360 04204 6
6 85360 04207 7
6 85360 04209 1
6 85360 04212 1
6 85360 04214 5
6 85360 04176 6
6 85360 04180 3
6 85360 04182 7
6 85360 04184 1
6 85360 04187 2
6 85360 04188 9
6 85360 04190 2
6 85360 04191 9
6 85360 04192 6
6 85360 04193 3
6 85360 04194 0
6 85360 04195 74
5
5
5
5
7.5
7.5
7.5
7.5
10
10
10
15
15
15
20
20
25
25
30
30
17
17
17
17
25.6
25.6
25.6
25.6
34.1
34.1
34.1
51.2
51.2
51.2
68.2
68.2
85.2
85.2
102.2
102.2
208
240
480
600
208
240
480
600
240
480
600
240
480
600
480
600
480
600
480
600
1-3
1-3
1-3
3
1-3
1-3
1-3
3
1-3
1-3
3
1-3
1-3
3
1-3
3
3
3
3
3
THREADED HEATER
ROD SIZE
1 PH
AMPS
3 PH
HP or
WATTS
1/2”-13 NC
1/2”-13 NC
1/2”-13 NC
1/2”-13 NC
1/2”-13 NC
1/2”-13 NC
1/2”-13 NC
1/2”-13 NC
1/2”-13 NC
1/2”-13 NC
1/2”-13 NC
1/2”-13 NC
1/2”-13 NC
1/2”-13 NC
1/2”-13 NC
1/2”-13 NC
1/2”-13 NC
1/2”-13 NC
1/2”-13 NC
1/2”-13 NC
12.5
13.8
6
4.8
21.3
18.1
9
7.2
25.7
12.8
9.6
37.7
18.8
14.5
24.8
19.3
31.1
24
36.9
28.9
6.0W
6.0W
6.0W
6.0W
6.0W
6.0W
6.0W
6.0W
1/10 HP
1/10 HP
1/10 HP
1/10 HP
1/10 HP
1/10 HP
1/10 HP
1/10 HP
1/3 HP
1/3 HP
1/3 HP
1/3 HP
20.8
24
10.4
–
36.6
31.3
15.6
–
41.7
21.6
–
64.1
32.1
–
42.5
–
–
–
–
–
FAN & FAN
AIR
MOTOR
MOTOR
VOLTAGE
RPM
208
1400
240
1400
240
1400
240
1400
208
1400
240
1400
240
1400
240
1400
240
1550
240
1550
240
1550
240
1550
240
1550
240
1550
240
1550
240
1550
240
1550
240
1550
240
1550
240
1550
AIR
VOL.
CFM
270
270
270
270
270
270
270
270
500
500
500
750
750
750
1000
1000
1300
1300
1800
1800
TEMP.
MAX
RISE THROW
60°F
60°F
60°F
60°F
85°F
85°F
85°F
85°F
63°F
63°F
63°F
63°F
63°F
63°F
63°F
63°F
61°F
61°F
53°F
53°F
16’
16’
16’
16’
18'
18’
18’
18’
20’
20’
20’
28’
28’
28’
32’
32’
34’
34’
38’
38’
MFG.
HEIGHT
8’
8’
8’
8’
8'
8’
8’
8’
9’
9’
9’
11’
11’
11’
13’
13’
14’
14’
15’
15’
SHIP
WT.
(LBS.)
26
26
31
31
27
27
31
31
62
72
72
68
78
80
78
80
136
142
142
142
ACCESSORIES
CATALOG NO.
UPC
DESCRIPTION
SHIP WT. (LBS)
CWB1A
6 85360 01820 1
Combination wall/ceiling bracket for 5KW thru 15KW units
4
CWB2A
6 85360 15240 0
Same as above but for 20KW thru 50KW units
14
UHTA1*
6 85360 15243 1
UHTA2*
6 85360 15244 8
Double-Pole Thermostat (60-120°F) for 3 PH IUH520 and IUH524, 3 PH
1
IUHDS30*
6 85360 01995 6
3-pole power disconnect switch kit for field installation on all horizontal unit
heaters rated 24 amps or less.
1
IUHDS63*
6 85360 01996 3
3-pole power disconnect switch kit for field installation on all horizontal unit
heaters 10KW and above rated 24 to 50 amps.
1
IUHSW
6 85360 03672 4
Summer-Winter Fan Switch Kit. Field installed.
Provides summer fan operation.
1
Single-Pole Thermostat kit 60-120°F temp.range for field installation
in all units except 3 PH IUH520 and IUH524, 3 PH
1
NOTE: When controls are to be factory-installed, list unit, control, and factory installation adder separately.
DIMENSIONS (see diagram on facing page)
KW SIZE
A
B
C
D
E
F
G
H
I
J
5-7.5
14”
12-1/2”
12-3/8”
5-1/2”
13”
1-3/4”
1-3/8”
1-1/2”
(2) 1/2”, 3/4”
1/2”
10-20
18”
18”
17-1/2”
9-15/32”
*
2”
2-1/2”
2-1/4”
(2) 3/4”, 1”
(3) 1”, 11/4”, 1-1/2”
25-30
26”
24”
23-1/8”
9-15/32”
20”
2”
2-3/4”
2-1/4”
(2) 1”, 1 1/2”
(3) 1”, 1-1/2”, 2”
NOTE: *13 in. for 10-15 kW units; 16 in. for 20 kW unit. 5 kW and 7.5 kW can be used in horizontal vertical position. Heaters come equipped with ceiling mounting bracket for horizontal or vertical flow
mounting or any position between.
For the latest models and information, please visit our website at www.qmarkmep.com35
UNIT HEATERS
CUSTOM CABINET UNIT HEATER
CU900 SERIES
AVAILABLE COLORS
Navajo Northern Charcoal
White
White
Gray
NEUTRAL GRAY
WITH OPTIONAL
ARCHITECTURAL-STYLE
GRILLE IN
STATUARY BRONZE
Neutral
Gray
Custom
Colors
Statuary
Bronze
Desert
Tan
Gloss
Black
Aluminum
IDEAL SPACES | School Hallways; Churches; Transportation Terminals; Stairwells; Entrance Ways; Vestibules; Lobbies;
Mechanical Rooms
COLORS | Neutral Gray; Charcoal Gray; Aluminum; Navajo White; Northern White; Statuary Bronze; Desert Tan; Gloss Black;
Custom Colors Available
DIMENSIONS | 26-3/8" H x 9-3/4" D (length varies)
•
16 air inlet/outlet combinations that are all field-changeable
•
BMS-compatible
•
TEMP RANGE | 55°-85° F
CFM | 200-1000
•
One-person maintenance on ceiling applications with
hinged front panel
Thermal safety cutout - installed with direct contact to
the heating element. Automatically shuts off the heater
in the event of overheating reactivates the heater when
operating temperature returns to normal
•
•
Cabinet constructed of heavy 16-gauge cold-rolled steel
to provide strength and finished with a polyester powder
coating for corrosion resistance
Built-in thermostat*– single-pole, snap-action thermostat
with remote bulb sensor located directly in the air intake
•
Tamper-resistant, two-position selector switch to select full
heat at high fan speed and reduced heat at low fan speed*
•
Motors are mounted with automatic thermal overload
protection; motor fuse protection is provided on all
heaters to meet safety requirements
•
Automatic fan delay eliminates cold drafts on start-up
and discharges residual heat from the heater body
during shut down
•
Plate fin element - steel fins are copper-brazed to lowwatt density, steel-sheathed tubular heating elements
•
Front cover interlock de-energizes unit when front cover
is removed for added safety
•
Element is finished with aluminized paint for corrosion
resistance
•
Disposable air filter mounted in inlet air stream; optional
permanent and washable aluminum filters available
•
Fins and elements are arranged in a uniform grid pattern
and fit closely into the discharge area to assure that all
outgoing air passes through the heating element
•
Standard stamped louvered grilles; optional architectural-style grille available; optional aluminum wall louver
available, ideal for exterior masonry or panel walls
*Optional feature. Contact sales representative or factory regarding optional features available, including: built-in fan switch; 120V control, electronically
controlled outside air damper; inlet and discharge duct collars; dead-front and fused dead-front disconnect switches; built-in night set back relay; and trim kits.
See page 39 to find out how to order cabinet unit heaters.
36
UNIT HEATERS
MODELS & SPECIFICATIONS
SERIES
KW
BTU/HR
FINAL AIR
TEMP
(Deg. F)
CU935
35 in. (L)
120 LBS.
2
3
4
5
6
7
8
6,826
10,239
13,652
17,065
20,478
23,891
27,304
85
98
111
123
136
148
161
CU945
45 in. (L)
160 LBS.
4
6
8
10
12
14
16
13,652
27,478
27,304
34,130
40,956
47,782
54,608
85
98
111
123
136
148
161
CU958
58 in. (L)
200 LBS.
6
8
10
12
14
16
20,478
27,304
34,130
40,956
47,782
54,608
85
96
103
111
118
128
CU968
68 in. (L)
260 LBS.
6
9
12
15
18
21
24
20,478
30,717
40,956
51,195
61,434
71,673
81,912
85
98
111
123
136
148
161
CU978
78 in. (L)
300 LBS.
8
12
16
20
24
28
32
27,304
40,956
54,608
68,260
81,912
95,564
109,216
85
98
111
123
136
148
161
CFM*
208
1 PH
60 HZ
208
3 PH
60 HZ
240
1 PH
60 HZ
240
3 PH
60 HZ
277
1 PH
60 HZ
347
1 PH
60 HZ
380**
3 PH
60 HZ
480
3 PH
60 HZ
600
3 PH
60 HZ
250
10
15
20
25
30
34
39
6
9
12
15
17
20
23
9
13
17
22
26
30
34
6
8
10
13
15
18
20
8
12
15
19
22
26
30
7
9
12
15
18
21
24
4
5
7
8
10
11
13
3
4
6
7
8
9
10
3
4
5
6
7
7
8
500
20
30
40
48
59
68
78
12
18
23
29
34
40
46
18
26
34
43
51
59
68
11
16
20
25
30
35
40
16
23
30
37
44
52
59
13
18
24
30
36
41
47
7
10
13
16
19
22
25
6
8
11
13
16
18
20
5
7
9
11
13
15
17
750
30
40
48
59
68
78
18
23
29
34
40
46
26
34
43
51
59
68
16
20
25
30
35
40
23
30
37
44
52
59
18
24
30
36
41
47
10
13
16
19
22
25
8
11
13
16
18
20
7
9
11
13
15
17
750
31
45
60
74
88
-
19
27
35
44
52
60
69
27
39
52
64
77
89
-
16
24
31
38
45
52
60
24
34
45
56
67
78
-
19
28
36
45
-
11
16
20
25
29
34
38
9
13
16
20
24
27
31
8
11
13
16
19
22
25
1,000
41
60
79
-
24
36
47
58
69
80
91
36
52
69
86
-
21
31
41
50
60
70
79
31
46
60
74
-
25
37
48
-
14
20
27
33
39
45
-
12
17
21
26
31
36
41
10
14
18
21
25
29
33
NOTE: RED numbers represent circuit breakers or fused disconnect required. **380V units will operate with a 16% reduction in heating capacity. +Based on 60°F inlet air temperature. *Values shown is high speed.
MULTIPLE AIR FLOW COMBINATIONS
For the latest models and information, please visit our website at www.qmarkmep.com37
UNIT HEATERS
ACCESSORIES
CATALOG NO.
CU935RTK
CU945RTK
CU958RTK
CU968RTK
CU978RTK
CU935BK
CU945BK
CU958BK
CU968BK
CU978BK
CU935AWL
CU945AWL
CU958AWL
CU968AWL
CU978AWL
CU935WF
CU945WF
CU958WF
CU968WF
CU978WF
DESCRIPTION
Ceiling or Wall Recess Trim Kit
Floor/Toe-Space Base Kit
100% Outside Air, Exterior
Aluminum Wall Louver
Permanent, Reusable
Washable Filter
COMPATIBLE
WITH
CU935
CU945
CU958
CU968
CU978
CU935
CU945
CU958
CU968
CU978
CU935
CU945
CU958
CU968
CU978
CU935
CU945
CU958
CU968
CU978
FUNCTION
Provides a neat finish to semi-recessed or
full recessed application.
16 gauge, muted black base is recessed from the
heater front and sides to provide an attractive and
practical floor mounting application.
Used on exterior of masonry or panel walls of 2-3/4”
or greater to provide a finished exterior
For heaters 100% outside dampers.
Replaces standard filter Washable filter can be
cleaned and replaced.
SHIP WT. (LBS)
3
4
5
6
7
9
10
11
13
15
5
6
7
9
10
4
6
8
10
12
OPTIONAL FACTORY-INSTALLED ACCESSORIES
ACCESSORY
2-STAGE
THERMOSTAT
Built-or Remote
120V CONTROL
Internally Generated
MANUAL RESET
DEAD FRONT
DISCONNECT SWITCH
DEAD FRONT FUSED
DISCONNECT SWITCH †
SUMMER FAN SWITCH
ON/OFF SWITCH
KEY LOCK FOR
FRONT COVER
NIGHT SET-BACK
RELAY 24V or 120V
MOTORIZED 100%
OUTSIDE AIR DAMPER*
DESCRIPTION
Standard
Optional
Standard
Optional
Built-in (or remote-mounted) single-pole, single-stage thermostat that cycles the element(s) and fan. Fan speed and element
wattage selected by the built-in HIGH or LOW selector switch.
Built-in (or remote-mounted) two-stage thermostat that cycles 2/3 of the element for during first stage and full heat during second
stage. Fan cycles on high speed only.
Control supply is internally generated 24V. Field supplied 24V control supply can be applied to heater. (Requires removing only
one jumper wire in the control panel).
120V internally generated control voltage is available. Field supplied 120V control supply can be applied to heater. (Requires
removing only one jumper wire in the control panel.)
Standard
Heater is supplied with auto-reset over temperature cutout.
Optional
Manual Reset over temperature cutout wired into control circuit. Supplied in addition to auto-reset cutout.
Standard
Supply terminal block in the control compartment.
Optional
A three pole non-fused disconnect switch disconnects power to the heater. Design prevents entry into the control compartment
until disconnect switch is turned to the OFF position.
Standard
Supply terminal block in the control compartment.
Optional
A three pole non-fused disconnect switch and circuit breaker(s) sized to the heater load protects heater and disconnects power
to the heater. Design prevents entry into the control compartment until disconnect switch is turned to the OFF position.
Standard
Fan cycles as the heat cycles on and off.
Optional
Built-in switch provides continuous fan operation with or without heat, or automatic fan cycling as the heat cycles on and off.
Standard
No switch supplied.
Optional
Built-in switch provides continuous fan operation with or without heat, or automatic fan cycling as the heat cycles on and off.
Standard
Two (2) slotted head spring latches.
Optional
Two (2) toolhead key lock style spring latches prevent unauthorized adjustment of controls and provides additional safety from
injury due to contact with internal components.
Standard
Heater will not set back at night.
Optional
Ability to set-back heater from energy management system that supplies (Specify - 24V or 120V) to relay holding coil for day operation.
Standard
Return air only.
24V electronically controlled damper with rear mounted duct collar permits outside air to enter the chamber at 100%. If power is
interrupted at the heater, outside damper remains in the open/closed position from the last switch setting. Damper fully opens in
less than 2 minutes when selector switch is in the open damper* position. (Available only with heaters having 24V control supply.
Cannot be used with 120V control supply or with bottom inlet configuration)
Slotted louver grilles.
Collars provide easy connection of field supplied duct work. We do not recommend exceeding 0.2 in. wg external static pressure.
Heater with duct collars are supplied with a single speed high static motor.
Slotted louver grilles.
Architectural styled extruded aluminum grille to enhance the appearance of the cabinet unit heater. This option is only available
for both inlet and discharge openings ordered at the same time. Can not be ordered separately.
Optional
INLET OR DISCHARGE
DUCT COLLAR(S)
Standard
ARCHITECTURAL
EXTRUDED ALUMINUM
GRILLES
Standard
Optional
Optional
NOTE: Plus price of circuit breaker. *Need to add summer fan switch and heat on/off switch. Allow 4 to 6 weeks for shipment with these options.
†
38
UNIT HEATERS
DUCT COLLARS/GRILLES
FRONT COVER KEY LOCK
FILTER
OUTSIDE AIR DAMPER
HEAT ON-OFF SWITCH
NIGHT SETBACK RELAY
SUMMER FAN SWITCH
DISCONNECT SWITCH
MANUAL RESET
CONTROL SUPPLY
T’ STAT
CIRCUIT BREAKER
MODEL
VOLTS
DISCHARGE AIR
KW
INLET AIR
LENGTH
9
PHASE
PRODUCT
C
U
SERIES
HOW TO ORDER CABINET UNIT HEATERS - CU900
B
A = Architectural Extruded Aluminum Grille
0 = Standard Louver Grilles
I = Inlet Duct Collars/Discharge Louver Grille
D = Inlet Louver Grille/Discharge Duct Collar
B = Inlet Duct Collar/Discharge Duct Collar
Cabinet Unit Heater
900 Series
35
45
58
68
78
=
=
=
=
=
35”
45”
58”
68”
78”
Cabinet
Cabinet
Cabinet
Cabinet
Cabinet
Length
Length
Length
Length
Length
See Chart (2 KW = 02, 32 KW = 32)
20
24
27
34
38
48
60
=
=
=
=
=
=
=
208
240
277
347
380
480
600
Volt
Volt
Volt
Volt
Volt
Volt
Volt
Supply
Supply
Supply
Supply
Supply
Supply
Supply
Power
Power
Power
Power
Power (3-Phase Only)
Power (3-Phase Only)
Power (3-Phase Only)
1 = Single Phase Supply Power
3 = Three Phase Supply Power
F = Front Inlet Air Configuration
B = Bottom Inlet Air Configuration
F = Front Discharge Air Configuration
T = Top Discharge Air Configuration
Series Model Number
0 = Standard Lock
K = Key Lock
0 = Standard, No Outside Air Damper (must be Ø for bottom Inlet)
A= Motorized 100% Outside Air Damper
0 = Standard Throw-away Filter
P = Permanent “Washable” Filter
0 = Standard, No Night Setback Relay
1 = Night Setback Relay (120 Volt Holding Coil)
2 = Night Setback Relay (24 Volt Holding Coil)
0 = Standard, No ON - OFF Switch
S = ON - OFF Switch
0 = Standard, No Disconnect Switch
S = Disconnect Switch
F = Fused (Circuit Breaker) Disconnect Switch
0 = Standard, No Summer Fan Switch
S = Summer Fan Switch
0 = Standard, No Manual Reset
M = Manual Reset
0 = No Circuit Breaker(s)
C = Circuit Breaker(s), Required or Optional
2 = Standard Internal Generated 24 Volt Control
1 = Internal Generated 120 Volt Control
1B = Standard Single Pole, Single Stage Built-In Thermostat
1R = Single Pole, Single Stage Remote (Wall Thermostat)
2B = Two Stage Built-In Thermostat
2R = Two Stage Remote (Wall Thermostat)
For the latest models and information, please visit our website at www.qmarkmep.com39
UNIT HEATERS
STOCK CABINET UNIT HEATER
CUS900 SERIES
NEUTRAL
GRAY
IDEAL SPACES | School Hallways; Churches; Transportation Terminals; Stairwells; Entrance Ways; Vestibules; Lobbies;
Mechanical Rooms
COLORS | Neutral Gray
DIMENSIONS | 35 or 45" L x 26-3/8" H x 9-7/8" D
TEMP RANGE | 60°-85° F
CFM | 200-500
•
Terminals for direct connection to BAS or EMS
•
High/low heat setting
•
Built in disconnect switch and thermostat
•
All 3-phase heaters have balanced heating load
•
Field-convertible units available or voltage specific
•
Two cabinet sizes - 35 in. and 45 in.
MODELS & SPECIFICATIONS
KW
CATALOG NO.
UPC
HI
CFM
LO
HI
LO
DIM
250
200
35” W x
26-3/8” H x
9-7/8” D
400
45” W x
26-3/8” H x
9-7/8” D
NON-FIELD CONVERTIBLE MODELS (VOLTAGE SPECIFIC)
CUS93505271FFNC
6 85360 16511 0
CUS93505483FFNC
6 85360 16513 4
CUS94510271FFNC
6 85360 16515 8
CUS94510483FFNC
6 85360 16517 2
CONVERTIBLE MODELS
CUS93505203FF*
CUS93505243FF*
CUS93505483FF*
CUS93505603FF*
CUS94510203FF*
CUS94510243FF*
CUS94510483FF*
CUS94510603FF*
6 85360 01791 4
6 85360 01792 1
6 85360 01793 8
6 85360 01794 5
6 85360 01795 2
6 85360 01796 9
6 85360 01797 6
6 85360 01798 3
5
10
5
10
3.3
6.7
3.3
6.7
500
250
500
200
400
45” W x
26-3/8” H x
9-7/8” D
MOTOR
FANS
WT. (LBS.)
120
1
1
160
120
1
2
160
VOLTS/PH.
AMPS
277V/1
18.0
480V/3
6.0
277V/1
36.0
480V/3
12.0
208V/3
240V/3
480V/3
600V/3
208V/3
240V/3
480V/3
600V3
14.0
12.0
6.0
4.8
34.0
15.0
12.0
9.0
NOTE: *Factory supplied 208V or 240V, 3PH field convertible to 1 PH, 480V 3 PH convertible to 277V 1 PH, 600V 3 PH convertible to 347V 1 PH. **Amps shown are 3 PH, High heat operation. Field Convertible to 1PH.
ACCESSORIES
CATALOG NO.
CU935RTK
CU945RTK
CU935BK
CU945BK
CU935AWL
CU945AWL
CU935WF
CU945WF
40
DESCRIPTION
Ceiling or Wall Recess Trim Kit
Floor/Toe-Space Base Kit
COMPATIBLE
WITH
CU935
CU945
CU935
CU945
100% Outside Air, Exterior
Aluminum Wall Louver
CU935
Permanent, Reusable
Washable Filter
CU935
CU945
CU945
FUNCTION
SHIP WT. (LBS)
Provides a neat finish to semi-recessed or
full recessed application.
3
16 gauge, muted black base is recessed from the
heater front and sides to provide an attractive and
practical floor mounting application.
Used on exterior of masonry or panel walls of 2-3/4 in.
or greater to provide a finished exterior
For heaters 100% outside dampers.
9
Replaces standard filter Washable filter can be
cleaned and replaced.
4
10
5
6
4
6
UNIT HEATERS
FINNED TUBE ELECTRIC|DUCT HEATER
•
Available CSA- and UL-listed in slip-in or flanged
configurations with heavy gauge galvanized steel frame
and terminal box construction
•
All units include primary and secondary thermal protection
•
Designed for vertical or horizontal airflow in either direction
•
Finned elements are constructed with highest Grade-A 80/20
nickel-chromium-resistance wire, helically wound and centered
within a sheath of either copper-plated or stainless steel,
compacted with magnesium oxide to assure excellent heat
transfer and double sealed
•
Heat output up to 1000 kW
•
Variety of construction styles, features and control options
IDEAL SPACES
Office Buildings; Retail Stores; Warehouses;
Schools; Hotels; Hospitals
OPEN COIL ELECTRIC|DUCT HEATER
•
Available CSA- and UL-listed in slip-in or flanged configurations with
heavy gauge galvanized steel frame and terminal box construction
•
NEMA 12 and NEMA 4 models available
•
All units include primary and secondary thermal protection
•
Designed for vertical or horizontal airflow in either direction
•
Alternate constructions are available for oven heaters, round duct,
bottom insert and rain tight installations
•
Elements are constructed using only the highest Grade-A 80/20
nickel-chromium resistance wire with stainless steel terminals
•
Custom engineered - optional construction features include recessed, dust tight or insulated terminal box, insulated flanges and
protective screens.
•
Heat output up to 1000 kW
•
Variety of construction styles, features and control options
IDEAL SPACES
Office Buildings; Retail Stores; Warehouses;
Schools; Hotels; Hospitals
RATING AND SIZES
The duct heaters are custom designed at no extra charge to your exact size, wattage, voltage, phase and number of steps. Any duct size from W = 6 in. and H = 6 in. minimum to
W = 144 in. and H = 96 in. maximum, wattages up to 1000 kW can be furnished. Base price depends upon duct size and kW rating; base price is the same for single or three phase
and does not change with number of steps. For practical design of heater, minimum recommended kW per step is .5 KW for 208V, 240V single-phase; 1.0 kW for 277V or 480V
single-phase and 2.0 kW for 208V. 240V, 480V or 600V 3-phase.
For the latest models and information, please visit our website at www.qmarkmep.com
41
UNIT HEATERS
PLENUM-RATED UNIT HEATER
MSPH SERIES
CONCEALED SPACE USE - ZERO CLEARANCE
NEUTRAL GRAY
IDEAL SPACES | Concealed Areas; Concession Stands; Bathrooms; Plenum Areas; Entrance Ways
COLORS | Neutral Gray
DIMENSIONS | Varies (see specifications)
TEMP RANGE | 40°-90° F
CFM | 350-1000
•
42
Plenum-rated approved for installations in concealed
spaces (between finished ceiling and drop ceiling,
plenum space, or inside a plenum). It may be installed
in areas that are not readily accessible and may be
installed for freeze protection
•
Timed blower on/off delay
•
External 24Vthermostat control (not included)
•
PSC-type 2-speed motor (ex. 480V models)
•
Compact size, zero clearance, design for horizontal
installation
•
Multiple heat rise selection
•
Connects to duct work for home extensions – eliminates
running duct work to HVAC saving money and time
•
20-gauge all powder coated steel construction
•
Acoustic fiberglass insulation
•
High limit thermal cutout - automatic reset
•
Single point power connection
•
Built-in disconnect switch
•
Heavy-duty steel finned heating element
•
Fan-only option
•
Quiet, efficient, forward-curved centrifugal blower
UNIT HEATERS
MODELS & SPECIFICATIONS
LOW SPEED*
CATALOG NO.
UPC
MSPH138124
MSPH132124
MSPH137124
MSPH138324
MSPH132324
MSPH134324
MSPH158124
MSPH152124
MSPH157124
MSPH158324
MSPH152324
MSPH154324
MSPH158124L
MSPH152124L
MSPH157124L
MSPH158324L
MSPH152324L
MSPH154324L
MSPH1758124
MSPH1752124
MSPH1757124
MSPH1758324
MSPH1752324
MSPH1754324
MSPH1102124
MSPH1107124
MSPH2102124
MSPH2107124
MSPH1108324
MSPH1102324
MSPH1104324
MSPH2108324
MSPH2102324
MSPH2104324
MSPH1158324
MSPH1152324
MSPH1154324
MSPH2152324
MSPH2154324
6 85360 14994 3
6 85360 15010 9
6 85360 15016 1
6 85360 14996 7
6 85360 15012 3
6 85360 15014 7
6 85360 15006 2
6 85360 14998 1
6 85360 15004 8
6 85360 15008 6
6 85360 15000 0
6 85360 15002 4
6 85360 15104 5
6 85360 15096 3
6 85360 15102 1
6 85360 15106 9
6 85360 15098 7
6 85360 15100 7
6 85360 15026 0
6 85360 15018 5
6 85360 15024 6
6 85360 15028 4
6 85360 15020 8
6 85360 15022 2
6 85360 15030 7
6 85360 15036 9
6 85360 15108 3
6 85360 15114 4
6 85360 15038 3
6 85360 15032 1
6 85360 15034 5
6 85360 15116 8
6 85360 15110 6
6 85360 15112 0
6 85360 15044 4
6 85360 15040 6
6 85360 15042 0
6 85360 15118 2
6 85360 15120 5
PHASE
KW
1
3
3
3
1
5
3
5
1
5
3
5
1
7.5
3
7.5
1
10
1
10
3
10
10
3
15
3
15
VOLTS
AMP*
208
240
277
208
240
480
208
240
277
208
240
480
208
240
277
208
240
480
208
240
277
208
240
480
240
277
240
277
208
240
480
208
240
480
208
240
480
240
480
15.32
13.4
11.63
9.23
8.12
4.11
24.94
21.73
18.85
14.78
12.93
6.51
24.94
21.73
18.85
14.78
12.93
6.51
38.12
33.31
28.91
22.88
20.1
10.16
43.73
37.93
43.73
37.93
29.82
26.12
13.17
29.82
26.12
13.17
43.9
38.14
19.18
38.14
19.18
HIGH SPEED**
CFM
RISE
CFM
RISE
SHIP WT. (LBS)
HxWxL
350
27ºF
400
24ºF
57
12.5” x 19.5” x 24”
350
45ºF
400
39ºF
57
12.5” x 19.5” x 24”
850
20ºF
1000
16ºF
69
18” x 18” x 35.5”
850
28ºF
1000
24ºF
69
18” x 18” x 35.5”
850
37ºF
850
37º / 20ºF
69
18” x 18” x 35.5”
31ºF
1000
37ºF
31º / 16ºF
31ºF
850
37º / 20ºF
1000
31º / 16ºF
850
56ºF
1000
47ºF
850
56º / 28ºF
1000
47º / 24ºF
NOTE: *Total Amps including Resistive and Inductive loads. **Low and High speed fan operation is determined during installation of thermostat set up
** Low speed fan operation not available on 480V models.
† Tested @0.2” S.P.
ACCESSORIES
DESCRIPTION
OPENING
DIMENSIONS (W x H x D)
FRST10
Throw away filter, including rack for 3 & 5KW unit.
Inlet side
15” X 20” X 4.5”
SHIP WT.
(LBS)
4
FRWS15
Reusable filter, including rack for 3 & 5KW unit.
Inlet side
15” X 20” X 4.5”
4
FRLT20
Throw away filter, including rack for 7.5 to 15KW unit.
Inlet side
15” X 20” X 4.5”
5
FRWL25
CATALOG NO.
Reusable filter, including rack for 7.5 to 15KW unit.
Inlet side
15” X 20” X 4.5”
5
LKS10
Adjustable louver kit for 3 & 5KW units
Outlet side
15” X 20” X 4.5”
5.5
LKL15
Adjustable louver kit for 7.5 to 15KW units
Outlet side
15” X 20” X 4.5”
6
AES10
Aluminum Wall Louver kit for inside heated room for 3 & 5KW units
Inside room
Rough in: 13-11/16” X 13-3/4”
3
AESL15
Aluminum Wall Louver kit for inside heated room for 7.5 to 15KW units
Inside room
Rough in: 15-3/4” X 15-3/4”
3.5
Electronic Digital 2-Stage 24V Thermostat
Inside room
5 3/4” x 3-3/4” x 1-1/2”
4
Single Pole Field installed thermostat. Range 40° to 85°F
At heater
25A @ 240V resistive; 22A @ 277V
3
TH5220D1003
PRHT1
For the latest models and information, please visit our website at www.qmarkmep.com43
UNIT HEATERS
PLENUM-RATED UNIT HEATER
CHPR25 SERIES
CONCEALED SPACE USE - ZERO CLEARANCE
NEUTRAL GRAY
IDEAL SPACES | Between Finished Ceiling and Drop Ceiling; Plenum Space; Freeze Protection
COLORS | Neutral Gray
DIMENSIONS | 14" L x 12-1/2" H x 14" D
TEMP RANGE | 40°-90° F
•
Plenum-rated approved for installations in concealed
spaces (between finished ceiling and drop ceiling,
plenum space, or inside a plenum). It may be installed
in areas that are not readily accessible and may be
installed for freeze protection
•
Fan delay control. feature allows only warm air to be
distributed; optional alarm (240V) to alert automatic
thermal limit tripped (Model AFL240)
•
Built-in thermostat
•
18-gauge all steel casing with polyester powder coat
finish for corrosion protection
•
Control box gasket to keep out moisture and dust;
NEMA 12 construction
•
Steel finned low-watt density element.
High limit thermal cutout automatically shuts off
current in event of overheating and reactivates
the heater when temperature returns to normal
•
Fan motor completely enclosed, permanently
lubricated and thermally protected
•
Single point field wiring connection for easy
installation and maintenance
MODELS & SPECIFICATIONS
CATALOG
NO.
UPC NUMBER
VOLTS
HZ
KW
PHASE
BTU/HR
FPM
RISE
SHIP
AMPS
CHPR25
6 85360 14954 7
240
208
50/60
50/60
2.5
1.9
1
8530
6398
1880
60ºF
46ºF
10.7
9.42
ACCESSORIES
CATALOG NO.
AFL240
44
CFM | 150
UPC
6 8536015347 6
DESCRIPTION
Thermal Limit Alarm
SHIP
WT.
(LBS)
SHIP WT. (LBS)
1
26
HAZARDOUS ENVIRONMENT
45
HAZARDOUS ENVIRONMENT
EXPLOSION-PROOF
UNIT HEATER|GUX SERIES
NAVAJO
WHITE
IDEAL SPACES | Oil Refineries; Sewage Treatment Plants; Petrochemical Plants; Oil Rigs; Unattended Pumping Stations;
Chemical Storage/Handling Facilities; Paint Storage Areas; Other Hazardous Environments
COLORS | Navajo White
DIMENSIONS | Varies (see specifications)
•
TEMP RANGE | 50°-90° F
Heats areas classified as hazardous locations
designated as Class I, Group C & D Division 1 & 2
or Class II, Groups E, F, and G with a T3B ignition
temperature code rating (329°F, 165°C) or higher to
provide primary or supplementary heating for
comfort or freeze protection
•
Pre-wired, self-contained control center. Standard
controls include automatic reset thermal limit, magnetic
contactor, and 24V control circuit transformer
•
An automatic reset high limit cutout unit is standard
(optional additional manual reset high limit cutout
available)
CFM | 700-2330
•
Optional factory built-in thermostat, disconnect switch,
fan selector switch, 120V control circuit, and pilot light
•
Advanced heat exchanger design allows lower operating
temperatures from liquid to air heat exchanger with steel
tubes, aluminum fins, a non-toxic heat transfer fluid, and
a pressure relief plug
•
Ball bearing permanently lubricated; explosion-proof
motor has built-in thermal overload protection
•
Powder-coated heavy-gauge steel cabinet
surrounding 14-gauge heavy-duty steel frame
supports internal components
DIMENSIONS
UNIT SIZE
46
A
C
B
D
E
3-10kW
IN.
19-1/8
MM
486
IN.
23-7/8
MM
606
IN.
21
MM
533
IN.
3-1/5
MM
89
IN.
13-5/8
MM
346
15-20kW
25
635
27-7/8
708
21
533
4-13/32
112
17-5/8
448
25-30kW
32-1/8
816
31-7/8
810
21-3/4
552
5-1/2
140
21-5/8
549
HAZARDOUS ENVIRONMENT
MODELS & SPECIFICATIONS
CATALOG NO.
UPC
GUX300812
GUX300832
GUX300412
GUX300432
GUX3004832
GUX300632
GUX500812
GUX500832
GUX500412
GUX500432
GUX5004832
GUX500632
GUX750812
GUX750832
GUX750412
GUX750432
GUX7504832
GUX750632
GUX1000832
GUX1000412
GUX1000432
GUX10004832
GUX1000632
GUX1500832
GUX1500432
GUX15004832
GUX1500632
GUX20004832
GUX2000632
GUX25004832
GUX2500632
GUX30004832
GUX3000632
6 85360 03470 6
6 85360 03477 5
6 85360 03448 5
6 85360 03452 7
6 85360 03458 4
6 85360 03468 3
6 85360 03503 1
6 85360 03508 6
6 85360 03481 2
6 85360 03486 7
6 85360 03491 1
6 85360 03501 7
6 85360 03530 7
6 85360 03532 1
6 85360 03513 0
6 85360 03517 8
6 85360 03521 5
6 85360 03528 4
6 85360 03404 1
6 85360 03387 7
6 85360 03390 7
6 85360 03396 9
6 85360 03402 7
6 85360 03420 1
6 85360 03408 9
6 85360 03411 9
6 85360 03418 8
6 85360 03427 0
6 85360 03434 8
6 85360 03436 2
6 85360 03439 3
6 85360 03440 9
6 85360 03444 7
HEATER
VOLTS
208
208
240
240
480
600
208
208
240
240
480
600
208
208
240
240
480
600
208
240
240
480
600
208
240
480
600
480
600
480
600
480
600
WATTS
(K/W)
3
3
3
3
3
3
5
5
5
5
5
5
7.5
7.5
7.5
7.5
7.5
7.5
10
10
10
10
10
15
15
15
15
20
20
25
25
30
30
PHASE
1
3
1
3
3
3
1
3
1
3
3
3
1
3
1
3
3
3
3
1
3
3
3
3
3
3
3
3
3
3
3
3
3
CONTROL
VOLTS*
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
OUTPUT
BTU/HR.
10,236
10,236
10,236
10,236
10,236
10,236
17,060
17,060
17,060
17,060
17,060
17,060
25,590
25,590
25,590
25,590
25,590
25,590
34,120
34,120
34,120
34,120
34,120
51,180
51,180
51,180
51,180
68,240
68,240
85,300
85,300
102,360
102,360
TOTAL
AMPS
16.7
9.7
14.8
8.6
4.3
3.6
26.3
15.3
23.1
13.5
6.8
5.6
38.4
22.2
33.6
19.4
9.7
8.1
29.2
44.5
25.5
12.7
10.6
43
37.5
18.7
15.7
24.8
20.7
31.1
25.8
37.1
30.2
VOLUME AIR TEMP
CFM
RISE
700
13°F
700
13°F
700
13°F
700
13°F
700
13°F
700
13°F
700
22°F
700
22°F
700
22°F
700
22°F
700
22°F
700
22°F
840
27°F
840
27°F
840
27°F
840
27°F
840
27°F
840
27°F
840
36°F
840
36°F
840
36°F
840
36°F
840
36°F
1450
31°F
1450
31°F
1450
31°F
1450
31°F
1400
43°F
1400
43°F
2330
32°F
2330
32°F
2330
39°F
2330
39°F
THROW
28 ft.
28 ft.
28 ft.
28 ft.
28 ft.
28 ft.
28 ft.
28 ft.
28 ft.
28 ft.
28 ft.
28 ft.
28 ft.
28 ft.
28 ft.
28 ft.
28 ft.
28 ft.
32 ft.
32 ft.
32 ft.
32 ft.
32 ft.
47 ft.
47 ft.
47 ft.
47 ft.
43 ft.
43 ft.
54 ft.
54 ft.
54 ft.
54 ft.
SHIP WT.
(LBS)
135
135
135
135
135
135
135
135
135
135
135
135
135
135
135
135
135
135
140
140
140
140
140
160
160
160
160
171
171
216
216
216
216
SHIP
STATUS
AS
AS
C
C
C
C
C
C
AS
C
S
C
C
C
AS
C
S
C
C
C
C
S
C
AS
C
S
C
S
C
AS
C
AS
C
NOTE: Above models have built-in 24V control; optional 120V control is available (replace “2” suffix with “1” for 120V control). Includes element, motor, and transformer. All units with status “C” or “AS”
are made-to-order and are non-returnable.
ACCESSORIES
CATALOG NO.
UPC
DESCRIPTION
GUXPM12
6 85360 03379 2
Pole Mounting Bracket for units 3KW thru 10KW
GUXPM16
6 85360 03380 8
Pole Mounting Bracket for units 15KW thru 20KW
GUXPM18
6 85360 03381 5
GUXWM12
SUFFIX
DESCRIPTION
AM
Automatic and Manual reset limits
Pole Mounting Bracket for units 25KW thru 30KW
T
Thermostat, 20º-80ºF
6 85360 03382 2
Wall Mounting Kit for units 3KW thru 10KW
L
Pilot Light (HEATER ON)
GUXWM16
6 85360 03383 9
Wall Mounting Kit for units 15KW thru 20KW
K
Pilot Light (LIMIT TRIPPED)
GUXWM18
6 85360 03384 6
Wall Mounting Kit for units 25KW thru 30KW
GUXCM0
6 85360 03378 5
Ceiling/Hang Mounting Kit for all Models
S
Selector Switch (AUTO/FAN ONLY)
D
Disconnect Switch - 15 amp for heaters
rated 12 amps or lower
NOTE: Specify type of mounting bracket required at time of order entry.
Disconnect Switch - 30 amp for heaters
between 13-24 amps
Disconnect Switch - 60 amp for heaters
24 amps or higher
1*
120 Volt Control Transformer
E
Artic Construction
* - Change heater suffix “2” to “1” for this option
For the latest models and information, please visit our website at www.qmarkmep.com47
HAZARDOUS ENVIRONMENT
WASHDOWN
CORROSION-RESISTANT
UNIT HEATER|QWD SERIES
STAINLESS
STEEL
IDEAL SPACES | Wastewater Treatment Plants; Coal Handling Areas; Food Processing Plants; Greenhouses; Foundries;
Steel Mills; Cement Plants; Car Washes; Ship/Marine Docks
COLORS | Stainless Steel
DIMENSIONS | Varies (see specifications)
TEMP RANGE | 55°-90° F
CFM | 700-2400
•
Heater offers corrosion protection in harsh
environments with ability to be hosed down for cleaning
•
316 Stainless Steel-finned elements for improved
heat distribution
•
Completely enclosed ball bearing motor that is
epoxy-coated for moisture and corrosion resistance
•
14-gauge Stainless Steel wall/ceiling bracket provides
multiple options for mounting
•
NEMA 4X junction box protects against water and dust
•
•
16-gauge 304 Stainless Steel cabinet for longer life and
rust-resistance
Automatic temperature high reset limit activates
if the temperature gets too high
•
Wall thermostat WT11A is NEMA 4X Rated
•
24V controls improves safety with remote thermostat
DIMENSIONS
KW
2-10
12.5-39.0
48
A
13
20
B
19.5
31
C
18
27
D
19.5
24.2
HAZARDOUS ENVIRONMENT
MODELS & SPECIFICATIONS
CATALOG NO.
HEATER KW
VOLTS
QWD02112
QWD02812
QWD02212
QWD03112
QWD03812
QWD03212
QWD03712
QWD03832
QWD03232
QWD03432
QWD05812
QWD05212
QWD05712
QWD05412
QWD05832
QWD05232
QWD05432
QWD05632
QWD07812
QWD07212
QWD07712
QWD07412
QWD07832
QWD07232
QWD07432
QWD07632
QWD10212
QWD10712
QWD10412
QWD10832
QWD10232
QWD10432
QWD12812
QWD12212
QWD12832
QWD12232
QWD12432
QWD15812
QWD15212
QWD15412
QWD15832
QWD15232
QWD15432
QWD20412
QWD20232
QWD20432
QWD25832
QWD25232
QWD25432
QWD30832
QWD30232
QWD30432
QWD39432
2
2
2
3
3
3
3
3
3
3
5
5
5
5
5
5
5
5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
10
10
10
10
10
10
12.5
12.5
12.5
12.5
12.5
15
15
15
15
15
15
20
20
20
25
25
25
30
30
30
39
120
208
240
120
208
240
277
208
240
480
208
240
277
480
208
240
480
600
208
240
277
480
208
240
480
600
240
277
480
208
240
480
208
240
208
240
480
208
240
480
208
240
480
480
240
480
208
240
480
208
240
480
480
MOTOR
PHASE
1
1
1
1
1
1
1
3
3
3
1
1
1
1
3
3
3
3
1
1
1
1
3
3
3
3
1
1
1
3
3
3
1
1
3
3
3
1
1
1
3
3
3
1
3
3
3
3
3
3
3
3
3
OUTPUT BTU/
HR
6,824
6,824
6,824
10,236
10,236
10,236
10,236
10,236
10,236
10,236
17,060
17,060
17,060
17,060
17,060
17,060
17,060
17,060
25,590
25,590
25,590
25,590
25,590
25,590
25,590
25,590
34,120
34,120
34,120
34,120
34,120
34,120
42,650
42,650
42,650
42,650
42,650
51,180
51,180
51,180
51,180
51,180
51,180
68,240
68,240
68,240
85,300
85,300
85,300
102,360
102,360
102,360
133,068
HEATER
AMPS
16.7
9.6
8.3
25.0
14.4
12.5
10.8
8.3
7.2
3.6
24.0
20.8
18.1
10.4
13.9
12.0
6.0
7.2
36.1
31.3
27.1
15.6
20.8
18.0
9.0
7.2
41.7
36.1
20.8
27.8
24.1
12.0
60.1
52.1
34.7
30.1
15.0
72.1
62.5
31.3
41.6
36.1
18.0
41.7
48.1
24.1
69.4
60.1
30.1
83.3
72.2
36.1
46.9
MOTOR
VOLTS
120
208
240
120
208
240
277
208
240
480
208
240
277
480
208
240
480
240
208
240
277
480
208
240
480
240
240
277
480
208
240
480
208
240
208
240
480
208
240
480
208
240
480
480
240
480
208
240
480
208
240
480
480
MOTOR
PHASE
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
MOTOR AMPS
TEMP RISE
CFM
SHIP WT. (LBS.)
1.554
0.896
0.777
1.554
0.896
0.777
0.673
0.896
0.777
0.388
0.896
0.777
0.673
0.388
0.896
0.777
0.388
1.8
0.896
0.777
0.673
0.388
0.896
0.777
0.388
1.8
0.777
0.673
0.388
0.896
0.777
0.388
1.793
1.554
1.793
1.554
0.777
1.793
1.554
0.777
1.793
1.554
0.777
0.777
1.554
0.777
1.793
1.554
0.777
1.793
1.554
0.777
0.777
9
9
9
14
14
14
14
14
14
14
23
23
23
23
23
23
23
23
34
34
34
34
34
34
34
34
22
22
22
22
22
22
27
27
27
27
27
20
20
20
20
20
20
26
26
26
33
33
33
39
39
39
51
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
1450
700
700
700
700
700
700
700
1450
1450
1450
1450
1450
1450
1450
1450
1450
1450
1450
1450
2400
2400
2400
2400
2400
2400
2400
2400
2400
2400
2400
2400
2400
2400
2400
2400
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
75
60
60
60
60
60
60
60
75
60
60
60
60
60
60
60
60
60
60
60
60
110
110
110
110
110
120
120
120
120
120
120
120
120
120
120
ACCESSORIES (FACTORY-INSTALLED ONLY)
SUFFIX
T
L
S
D
E
M
P
DESCRIPTION
Thermostat
Pilot Light
Selector Switch
Disconnect Switch
Monel Element*
Manual Reset
Epoxy Coating
* Monel elements are subject to longer lead times. Please contact factory for details. All units other than standard models are non-returnable.
For the latest models and information, please visit our website at www.qmarkmep.com49
HAZARDOUS ENVIRONMENT
EXPLOSION-PROOF
CONVECTORS|ICG SERIES
NEUTRAL GRAY
IDEAL SPACES | Oil Rigs and Refineries; Sewage Treatment Plants; Petrochemical Plants; Pumping Stations;
Chemical Storage/Handling Facilities; Paint Storage Areas; Other Hazardous Areas
COLORS | Neutral Gray
•
Designed to heat areas classified as hazardous
locations designated for Class I, Groups B, C, & D.
Division 1 and 2 environments
•
•
DIMENSIONS | Varies (see specifications)
•
Polyester powder-coated heavy-gauge steel provides
excellent corrosion resistance
High quality, long life tubular elements with
high-grade resistance wire embedded in MGO,
centered in heavy gauge 1.25 in. diameter sheath
with 3 x 3.25 in. fins
•
Easily mounted with wall mounting brackets (included)
Explosion-proof junction boxes included for conduit
entry and ease of wiring
•
Sloped top cabinet prevents objects from being set on
top which could restrict airflow
DIMENSIONS
LENGTH (IN)
HEIGHT (IN)
WIDTH (IN)
1.8 and 3.6
KW
34
20
9
3.2 and 7.6
58
20
9
NOTE: Add 8-7/8 in. to total length of heater to allow for junction box on right
side of heater.
50
HAZARDOUS ENVIRONMENT
MODELS & SPECIFICATIONS
CATALOG NO.
UPC
T2A TEMPERATURE RATING (536º F)
ICG18001
6 85360 04000 4
ICG18081
6 85360 04020 2
ICG18083
6 85360 04025 7
ICG18041
6 85360 04004 2
ICG18043
6 85360 04008 0
ICG18071
6 85360 04018 9
ICG180481
6 85360 04011 0
ICG180483
6 85360 04014 1
ICG36081
6 85360 04088 2
ICG36083
6 85360 04091 2
ICG36041
6 85360 04069 1
ICG36043
6 85360 04072 1
ICG36071
6 85360 04085 1
ICG360481
6 85360 04074 5
ICG360483
6 85360 04077 6
ICG36063
6 85360 04083 7
ICG76081
6 85360 13595 3
ICG76083
6 85360 08562 3
ICG76041
6 85360 08555 5
ICG76043
6 85360 12131 4
ICG76071
6 85360 08561 6
ICG760481
6 85360 08557 9
ICG760483
6 85360 08558 6
ICG76063
6 85360 08559 3
T3A TEMPERATURE RATING (356º F)
ICG32081
6 85360 04065 3
ICG32083
6 85360 04066 0
ICG32041
6 85360 04061 5
ICG32043
6 85360 08648 4
ICG32071
6 85360 04046 4
ICG320481
6 85360 04062 2
ICG320483
6 85360 04063 9
ICG32063
6 85360 16059 7
HEATER VOLTS
WATTS (K/W)
PHASE
AMPS
BTU/HR
120
208
208
240
240
277
480
480
208
208
240
240
277
480
480
600
208
208
240
240
277
480
480
600
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
1
1
3
1
3
1
1
3
1
3
1
3
1
1
3
3
1
3
1
3
1
1
3
3
15.0
8.7
5.0
7.5
4.4
6.5
3.8
2.2
17.3
10.0
15.0
8.7
13.0
7.5
4.3
6.3
36.5
21.1
31.7
18.3
27.4
15.8
9.2
9.2
6,140
6,140
6,140
6,140
6,140
6,140
6,140
6,140
12,300
12,300
12,300
12,300
12,300
12,300
12,300
12,300
25,930
25,930
25,930
25,930
25,930
25,930
25,930
25,930
208
208
240
240
277
480
480
600
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
1
3
1
3
1
1
3
3
15.4
8.9
13.3
7.7
11.6
6.7
3.8
5.6
11,000
11,000
11,000
11,000
11,000
11,000
11,000
11,000
SHIP WT. (LBS)
SHIP STATUS
AS
S
C
S
C
C
C
C
S
C
S
C
C
C
S
C
C
C
C
C
C
C
C
C
46
58
94
C
C
C
C
C
C
C
C
84
ACCESSORIES (FACTORY-INSTALLED ONLY)
CATALOG NO.
DESCRIPTION
T
Thermostat 45°-85°F (Class I, Group C & D only)
CX
24V Control Contactor and Transformer (see note #2 below)
CX1
120V Control Contactor and Transformer (see note #3 below)
TB
Thermostat 45°-85°F (Class 1, Group B,C, & D)
NOTE: Units with factory built-in controls will increase in length by 2-3/4 in. over what is shown above. 480V unit heaters with built-in thermostat require “CX” option. All units with status “C” or “AS” are
made-to-order and are non-returnable. See below for availability status.
AVAILABILITY STATUS
SERIES
GUX
ICG
CODE DESCRIPTION
LEAD TIME
Code S - Stock unit (no built-in controls)
4 weeks
Code AS - Assemble to stock units (with or without built-in controls)
5 weeks
Code C - Custom (with or without built-in controls)
6 weeks
Code S - Stock unit (no built-in controls)
4 weeks
Code C - Custom (with or without built-in controls)
6 weeks
NOTE: All stock units with built-in controls are the same as code AS units
For the latest models and information, please visit our website at www.qmarkmep.com51
CEILING HEATERS
53
CEILING HEATERS
COMMERCIAL DOWNFLOW
CEILING HEATER
CDF SERIES
Phosphatized, baked enamel
finish: All sheet metal and extruded
aluminum parts, except the back
box, are phosphatized, then finished
by a baked enamel electrostatic
painting process.
AVAILABLE COLORS
Northern
White
Navajo
White
Elements: Steel fins are copper-brazed
to low-watt density, steel-sheathed,
tubular heating elements which are
arranged in a uniform grid pattern.
The grid covers the entire intake area,
resulting in uniform heating of all
discharged air.
NORTHERN
WHITE
Efficient Operation: The five-bladed
aluminum fan and the rugged
impedance-protected, totally-enclosed
motor, achieve efficient operation.
IDEAL SPACES | Bathrooms; Offices; Conference Rooms; Lobbies; Waiting Rooms; Entrance Ways
COLORS | Northern White; Navajo White
TEMP RANGE | 45°- 90°F
RECESSED | 23-3/4” W x 23-3/4” L x 7” D SURFACE | 16-1/2” W x 20” L x 5-3/4” D
CFM | 300
•
CDFSE “surface enclosures” are designed to mount flat
on the ceiling and extend only 6 in. into the room
•
Three adjustable airflow patterns from 14 ft. ceilings:
wide, narrow or asymmetrical patterns
•
CDFRE “recessed enclosures” have no protrusions
outside recess box, allowing the heater to recess only
7 in. into ceiling space. Mounts in T-Bar or permanent
ceiling with trim ring
•
Automatic fan delay eliminates cold drafts on start-up
and discharges residual heat from the heater body
during shut down
•
208V and 240V heaters can be field-converted from
single- to three-phase operation. 5,000-watt heater
can be field-converted to 3,800 or 2,500 watts and
4,000-watt heater to 3,000 or 2,000 watts
•
Automatic thermal cutout: shuts off the heater in the
event of over-heating and reactivates heater when
temperature returns to normal
•
Easy installation: Thumb pins align and temporarily
hold enclosure cover to heating section freeing both
hands to finish installation
•
BMS-compatible with use of relays
SUGGESTED
CONTROLS
view page 151
for more information
MS26 or M601W
54
CEILING HEATERS
MODELS & SPECIFICATIONS
CATALOG NO.
CDF548
CDF542
CDF547
CDF558
CDF552
CDF557
UPC
6 85360 01510 1
6 85360 01508 8
6 85360 01509 5
6 85360 01513 2
6 85360 01511 8
6 85360 01512 5
MOUNTING
Heater
Section Only
KW
BTU/HR
4/3/2
13.7/10.2/6.8
5/3.8/2.5
17.1/13/8.5
AMPS
19.2/14.2/9.6
16.7/12.5/8.3
14.4/10.8/7.2
24/18.3/12
20.8/15.8/10.4
18.1/13.7/9
VOLTS
208
240
277
208
240
277
PHASE
1-3
1-3
1
1-3
1-3
1
SHIP WT (LBS)
ACCESSORIES
CATALOG NO.
CDFSE
CDFRE
CDFSENW
CDFRENW
CDFT
CDF24R
CDFR12
CDFDS
CDSTK
CDFTR4
CDFTR7
UPC
DESCRIPTION
6 85360 01501 9
6 85360 01498 2
6 85360 14961 5
6 85360 14963 9
6 85360 01503 3
6 85360 01507 1
6 85360 01500 2
6 85360 01496 8
6 85360 01504 0
6 85360 01505 7
6 85360 01506 4
Surface-mounted enclosure (Navajo White) - to be used With above heater section. 20” L x 16-1/2” W x 5-3/4” D
Recessed-mounted enclosure (Navajo White) - to be used With above heater section. 23-3/4” L x 23-3/4” W x 7” D
Surface-mounted Northern White - to be used With above heater section. 20” L x 16-1/2” W x 5-3/4” D
Recessed-mounted Northern White - to be used With above heater section. 23-3/4” L x 23-3/4” W x 7” D
Integral thermostat SPST - Range 45 to 95°F
Relay (Time Delay 45-60 sec. to close when energized) requires 24V supply from remote source
Relay (Time Delay 45-60 sec. to close when energized) requires 120V supply from remote source
Power Disconnect Switch (3-Pole) 30 amps, 600 volts, 3Ø, 60 Hz
Trim Ring for mounting on permanent ceiling (cannot be factory installed)
208/240V Primary Transformer/24V sec. and 24V holding coil control relay
277V Primary Transformer/24V sec. and 24V holding coil control relay
27
27
SHIP WT
(LBS.)
10
18
10
18
1
1
1
1
1
1
1
NOTE: Factory-wired for highest wattage, field-convertible to lower wattages. Factory-wired 1-PH, field convertible to 3-PH dual-phase units, maximum amp draw is listed. Amperage shown is for single phase.
For factory installation of above controls, additional charges apply.
ADJUSTABLE AIRFLOW OPTIONS
WIDE PATTERN
(24x8 ft. coverage)
In standard ceiling
applications (8-10 ft.),
heater disperses the
air to give a gentle,
less pronounced pattern
while circulating all the
air from floor to ceiling.
24x8 ft.
coverage
17x10 ft.
coverage
ASYMMETRICAL
PATTERN
(17x10 ft. coverage)
Heated air is directed
in a specific direction,
allowing the heater
to be located where
space allows, with the
heated air delivered to
where it is required.
NARROW
PATTERN
(8x8 ft. coverage)
For high ceiling
applications (11-14 ft.),
fan concentrates the
heated air to ensure full
penetration to the floor level.
8x8 ft.
coverage
17x10 ft.
coverage
For the latest models and information, please visit our website at www.qmarkmep.com55
CEILING HEATERS
CEILING-MOUNTED FAN-FORCED HEATER
EFF SERIES
NAVAJO WHITE
IDEAL SPACES | Entryways; Hallways; Restrooms; Detention Environments; Lobbies
COLORS | Navajo White
GRILLE | 15-3/4” W x 19-1/8” L x 1” D BACK BOX | 14-3/8” W x 18-1/4” L
•
Accommodates pneumatic/electric or low voltage
controls commonly used with BMS Systems
•
Built in power on/off switch
•
When using wall thermostat, separate thermostat
wiring is required
SUGGESTED
CONTROLS
view page 151
for more information
MS26 or M601W
56
TEMP RANGE | 40°-90° F
CFM | 150
•
Automatic fan delay eliminates cold drafts on start-up
and discharges residual heat from the heater body
during shut down
•
Multiple mounting options: recessed, surface or T-Bar
•
Heavy duty 14-gauge louvered front cover grille with
tamper-resistant screws
CEILING HEATERS
MODELS & SPECIFICATIONS
UPC
VOLTS
WATTS
AMPS
BTU/HR.
SHIP WT. (LBS)
EFF1500
EFF3007
EFF4008
CATALOG NO.
6 85360 14810 6
6 85360 05907 5
6 85360 05913 6
EFF4007
6 85360 05912 9
EFF4804
EFF4807
EFF3003
EFF3006
EFF4003
EFF4006
EFF4803
EFF4806
EFF48483
EFF48483LV
6 85360 05916 7
6 85360 05919 8
6 85360 02108 9
6 85360 02109 6
6 85360 02111 9
6 85360 02114 0
6 85360 02118 8
6 85360 02121 8
6 85360 15584 5
6 85360 15586 9
5120
10239/5120
13652/6826
13652/10239
10239/5120
13652/10239
10239/5120
16382/12287
16382/12287
10239
10239
13652
13652
16382
16382
16382
16382
23
23
23
6 85360 05909 9
1500
3000/1500
4000/2000
4000/2000
3000/1500
4000/2000
3000/1500
4800/3600
4800/3600
3000
3000
4000
4000
4800
4800
4800
4800
12.5
10.8/5.4
19.2/9.8
EFF4004
120
277
208
240
208
277
240
240/208
277/240
347
600
347
600
347
600
480
480
16.7/14.4
14.4/12.5
20.0/17.3
17.3/15.0
8.6
5
11.5
6.7
13.8
8
5.8
5.8
23
23
23
23
23
23
23
23
23
23
23
23
NOTE: Factory-wired for highest wattage, field-convertible to lower wattages.
ACCESSORIES
CATALOG NO.
EFFSM
EFFR2 (24V)
EFFR12 (120V)
EFFTBF
EFFT1
EFFT2
EFFTR4
EFFTR7
UPC
6 85360 02098 3
6 85360 02097 6
6 85360 02096 9
6 85360 02099 0
6 85360 02102 7
6 85360 02103 4
6 85360 02100 3
6 85360 02101 0
DESCRIPTION
Surface Mounting Sleeve - Navajo White
Time delay relay, 45-60 seconds to close when energized;
Uses remote 24V or 120V power source
T-Bar Frame Kit
Single Pole T-Stat. (Field Installed)
Double Pole Thermostat. (Field Installed)
208/240V Primary Transformer 24V Relay
277V Primary 24V Sec. Transformer Relay
SHIP WT. (LBS)
6
1
4.5
1
2
1
1
For the latest models and information, please visit our website at www.qmarkmep.com57
CEILING HEATERS
CEILING-MOUNTED FAN-FORCED HEATER
QCH SERIES
NORTHERN WHITE
IDEAL SPACES | Basements; Offices; Converted Attics; Bathrooms; Workshops; Lobbies;
Hallways; Common Areas
COLORS | Northern White
GRILLE | 10-1/2” L x 12-1/2” W x 1” D BACK BOX | 9-3/4” L x 11” W x 3-3/4” D
•
Dual voltage and wattage
•
Built-in power on/off switch
•
•
TEMP RANGE | 45°-95° F
CFM | 65
•
Automatic fan delay eliminates cold drafts on start-up
and discharges residual heat from the heater body
during shut down
Thermal cutout to shut off heater in case of overheating
•
Recessed or surface installation options available
Easy installation with a three-piece design
•
Remote wall thermostat required
MODELS & SPECIFICATIONS
SUGGESTED
CONTROLS
view page 151
for more information
CATALOG NO.
UPC
VOLTS
QCH1101F
685360165028
120
QCH1151F
685360165035
120
QCH1202F
685360165042
240/208
QCH1207F
685360165059
277/240
WATTS
AMPS
1000
500
1500
750
2000/1500
1000/750
2000/1500
8.3
4.7
12.5
6.3
8.3/7.2
4.2/3.6
7.2/6.3
1000/750
3.6/3.1
SHIP WT. (LBS)
10
NOTE: Factory-wired for highest wattage, field-convertible to lower wattages.
ACCESSORIES
CATALOG NO.
MS26 or M601W
UPC
DESCRIPTION
QCHSM
6 85360 05872 6
Surface mounting sleeve, Northern White
QCHS1
6 85360 05873 3
1 in. Semi-Recessed Frame, Northern White
QCHS2
6 85360 05874 0
2 in. Semi-Recessed Frame, Northern White
QCHTBF
6 85360 08738 2
T-Bar Frame Kit, Northern White
NOTE: Requires two separate leads from heater to single-pole wall thermostat.
58
SHIP WT. (LBS)
2
5
SPECIALTY HEATERS
59
SPECIALTY HEATERS
TOE SPACE FAN-FORCED HEATER | QTS SERIES
•
Tangential blower for quiet operations
•
Ability to reduce wattage by half when needed
•
Thermal cutout indicated with pilot light protects
against overheating
•
Steel plate fin element In a uniform grid pattern for
uniform heating
•
Built-in thermostat models available
•
Three-piece construction for easy installation
•
Use with built-in thermostat or remote wall-mounted
thermostat
BLACK
IDEAL SPACES | Kitchens, Bathrooms;
Stairwells; Checkout Counters; Toll Booths
COLORS | Black; Northern White
GRILLE | 3-5/8” H x 15-3/8” W
BACK BOX | 3-1/2” H x 14-1/8” W X x 8-7/8” D
TEMP RANGE | 45°-85°F
MODELS & SPECIFICATIONS
CATALOG NO.
UPC
VOLTS
WATTS
AMPS
SHIP WT. (LBS)
QTS1100*
6 85360 06538 0
120
1125/563
9.4/4.7
10
QTS1104*
6 85360 06539 7
240
1125/563
4.7/2.3
208
844/422
4.1/2.0
QTS1500T**
6 85360 06541 0
QTS1504T**
6 85360 06543 4
120
240/208
1500/750
12.5/6.3
1500/750
6.3/3.1
1125/564
5.4/2.7
10
11
11
NOTE: * Models require QTSTSP or remote wall-mounted thermostat. ** Models shipped with single-pole thermostat installed. Add NW to catalog number for Northern White (ex. QTS1100NW).
ACCESSORIES
CATALOG NO.
60
UPC
DESCRIPTION
SHIP WT. (LBS)
QTSAG
6 85360 06532 8
Adapter Grille 3-1/2" H x 2-3/8" W
1
QTSTSP
6 85360 06533 5
120-240V Thermostat Kit
1
SPECIALTY HEATERS
UTILITY WELL HOUSE HEATER | WHT500 SERIES
•
Install it anywhere heat is needed to prevent pipes and other
water, hydraulic fluid or oil-filled equipment from freezing
•
Designed to provide automatic, 24-hour protection. Set
thermostat at any desired level and leave it
•
Aluminum-finned element provides fast heat and steel
sheath cools element for extended life
•
Heater cabinet is galvanized steel and epoxy painted for
corrosion protection
•
Thermostat is completely contained within control box
•
Quick 240/208V field conversion to 120V
•
All power supply and control wiring terminates in the
tamper-proof control box — no live voltage in element area
NEUTRAL GRAY
IDEAL SPACES | Pump houses; utility rooms;
relay stations; construction sheds; cabins
COLORS | Neutral Gray
DIMENSIONS | 21” L x 5” H x 3-1/2” D
TEMP RANGE | 40°-70°F
MODELS & SPECIFICATIONS
CATALOG NO.
WHT500
UPC
VOLTS
WATTS
AMPS
SHIP WT. (LBS)
6 85360 08049 9
240/208/120
500/376/500
2.1/1.8/4.2
6
FLOOR DROP-IN HEATER | FDI SERIES
•
Universal size combined with a heavy-duty grille
•
Quick Installation – mounts between floor joists parallel
or perpendicular
•
Overheat thermal protector
•
Flow pattern is 5 ft. wide and 4 ft. high
•
Push-on tab wire terminals
•
Quiet operation
SANDAL WOOD
IDEAL SPACES | Bedrooms; Living/Family Rooms;
Offices; Conference Rooms; Hallways; Lobbies;
Waiting Rooms
COLORS | Sandal Wood
GRILLE | 15-3/8" L x 8-3/4" W
BACK BOX | 14" L x 7-1/4" W x 6-5/8" D
TEMP RANGE | 55°-90°F
MODELS & SPECIFICATIONS
CATALOG NO.
FDI1500
UPC
6 85360 02626 8
FDI1504
6 85360 02628 2
FDITSP
6 85360 02619 0
VOLTS
120
240
208
CFM
80
80
80
WATTS
1500/750
1500/750
1125/563
120-240V Thermostat Kit
AMPS
12.5/6.3
6.3/3.1
5.4/2.7
SHIP WT. (LBS)
10
10
1
NOTE: *60 hz. single-phase. Do not install in bathroom or other areas where water may enter heater unit. Do not locate where air flow may be obstructed (under drapes, behind doors, etc.). Keep short side
36 in. min. and long side 3 in. min. from side walls. Do not install in ceiling or wall.
For the latest models and information, please visit our website at www.qmarkmep.com
61
SPECIALTY HEATERS
COUNTERFLOW ELECTRIC WALL FURNACE
CFWF SERIES
IDEAL SPACES | Bedrooms; Living/Family Rooms; Basements; Offices; Conference
NORTHERN
WHITE
Rooms; Hallways; Lobbies; Waiting Rooms
COLORS | Northern White
DIMENSIONS | 72-1/2”H x 14-1/8” W x 7” D
CFM | 300
•
Heater draws in cool air at top inlet, forcing air downward via fan over heating
element and then quietly discharging warm air thru bottom inlet
•
Warm air at floor creates a gentle convective process in room, preventing
stratification of warm air near ceiling and ensuring comfort for occupants
•
Heater can be surface-mounted or recessed into wall sections
(maximum depth of recess is 5-3/8 in.)
•
Heavy-duty open coil electric heating elements provides uniform heat and
long operating life
•
Digital 24V, two-wire electronic thermostat included with heater
•
Contemporary styling uses soft curves on all edges, avoiding sharp corners
of a square design
•
Large wiring compartment is accessible from front of heater enabling rapid,
easy hookup
•
Optional rear outlet package allows some heated air to adjoining rooms; mounted
inside wall behind heater
MODELS & SPECIFICATIONS
CATALOG NO
CFWF920
UPC
VOLTS
kW
AMPS
SHIP WT. (LBS)
6 85360 08643 9
120
9.2
39
60
NOTE: Unit can be surface-mounted or recessed (recess mount wall opening 75-1/2” H x 14-3/8” W).
ACCESSORIES
CATALOG NO
CFWFRO
62
UPC
DESCRIPTION
SHIP WT. (LBS)
6 85360 10716 5
Rear Outlet Package
6
CONVECTION HEATERS
63
CONVECTION HEATERS
INSTITUTIONAL
ELECTRIC CONVECTOR
KCJ SERIES
NEUTRAL
GRAY
IDEAL SPACES | Offices; Conference Rooms; Hallways; Lobbies; Waiting Rooms; Other Common Areas
COLORS | Neutral Gray
DIMENSIONS | 16" (H) x 5" (D) x (length varies)
•
Durable, tamper-resistant convection heat
•
•
Low operating temperatures of 140°F maximum
surface temperature in a 70°F ambient
Epoxy baked enamel finish insures resistance to
chipping, cracking and rusting
•
•
Internal, secured thermostat with 55° to 100°F range
Sloped top cabinet prevents objects from being set on
top, which could restrict airflow
•
12-gauge perforated steel provides rugged
resistance to vandalism
•
Internal DPST disconnect switch is accessible without
removing cover
MODELS & SPECIFICATIONS
64
CATALOG
NO.
VOLTS
KCJ400
KCJ408
KCJ404
KCJ407
KCJ500
KCJ508
KCJ504
KCJ507
KCJ750
KCJ758
KCJ754
KCJ757
KCJ753
KCJ1000
KCJ1008
KCJ1004
KCJ1007
KCJ1003
KCJ1006
KCJ1250
KCJ1258
KCJ1254
KCJ1257
KCJ1253
KCJ1256
KCJ1500
KCJ1508
KCJ1504
KCJ1507
KCJ1503
KCJ1506
KCJ2008
KCJ2004
KCJ2007
KCJ2003
KCJ2006
120
208
240
277
120
208
240
277
120
208
240
277
347
120
208
240
277
347
600
120
208
240
277
347
600
120
208
240
277
347
600
208
240
277
347
600
WATTS
(K/W)
400
500
750
1000
1250
1500
2000
AMPS
3.3
1.9
1.7
1.4
4.2
2.4
2.2
1.8
6.3
3.6
3.3
2.7
2.2
8.3
4.8
4.4
3.6
2.9
1.7
10.4
6
5.4
4.5
3.6
2.1
12.5
7.2
6.5
5.4
4.3
2.5
9.6
8.8
7.2
5.8
3.3
SHIP
WT.
(LBS)
40
45
55
65
80
95
DIMENSIONS
WATTS
LENGTH (IN) - A
HEIGHT (IN)
DEPTH (IN)
400
24
16
5
500
28
16
5
750
36
16
5
1000
48
16
5
1250
60
16
5
1500
72
16
5
2000
96
16
5
NOTE: Products are made-to-order and cannot be returned.
CONVECTION HEATERS
ARCHITECTURAL SILL-HEIGHT CONVECTOR
DBA & SHA SERIES
AVAILABLE COLORS
Navajo Northern Charcoal
White
White
Gray
Neutral
Gray
Custom
Colors
Statuary
Bronze
Desert
Tan
Gloss
Black
CHARCOAL
GRAY
Aluminum
IDEAL SPACES | Residential (DBA): Living Rooms; Bedrooms; Other Similar Areas with Floor-to-Ceiling Windows
Institutional and Commercial (SHA or DBA): Offices; Hallways; Lobbies; Condos; Conference Rooms;
Retail Spaces; Other Similar Areas
COLORS | Neutral Gray; Charcoal Gray; Navajo White; Northern White; Statuary Bronze; Desert Tan; Black;
Custom Colors, Clear, Bronze Anodized Finishes Available
DIMENSIONS | (DBA) 6" H x 3-5/8"D (Length varies)
66
DIMENSIONS | (SHA) 7" H x 5-5/8"D (Length varies)
•
DBA Series is approved for residential applications
•
•
Patented "Stair-Step" SHA heating element design
accommodates a multitude of applications and heating
needs (see diagram on next page)
Inside and outside corners can be ordered factory-cut
and mitered to fit difficult or unusual spaces
•
Right -or left-hand entry and built-in wire way
(equivalent to 3/4 in. conduit) with factory-installed wiring
•
Unique two-piece extruded aluminum “Snap-Lock”
closure design secures the one-piece top and front
grilles to the one-piece back and bottom providing
a rapid, secure fit all along the length of the unit
•
Full line of trim accessories, including matching blank
sections, end caps, filler sections, inside and outside
corners, diagonal end sections, and splice plates
•
Front/bottom inlet air grille utilizes slots which create
an attractive installation where inlet grille is visible
•
Optional built-in controls include: line-voltage
thermostat; two-stage thermostat; on/off switch;
transformer relay; power relay and pneumatic/switch
•
Blend into any décor with custom paint and anodizing
upon request
•
•
Units can be mounted on floor, wall, or pedestals
Easy connection of supply wiring from bottom, rear or
end, as well as multiple wiring of adjacent heaters from
one entry point
•
Customize space with wall-to-wall installation, or as
discrete units in standard lengths of 28 in. to 10 ft.
•
•
Units are available in a wide range of heating
capacities per foot length (see specifications)
Thermal limit switch with linear type (full length)
sensing bulb provides constant protection against
overheating from any cause
•
•
Architectural-style end sections give a finished look
when used as a stand-alone or where a wall-to-wall run
is not desired
Switch will automatically reset when normal
operating temperatures are restored
•
Discharge air openings in top grille are punched
slots which are pencil-proof for safety
CONVECTION HEATERS
SHA SERIES CONVECTOR HEATER
CONVENTIONAL CONVECTOR HEATER
PATENTED
STAIR-STEP DESIGN
The “Stair-Step” patented design of heating elements of
two- and three-element heaters controls the flow of air
through the heater resulting in cooler wall temperatures
compared to side-by-side arrangements of elements in
conventional heaters. This unique design provides a more
efficient and effective distribution of heat.
CABINET STYLES
Two cabinet styles are available. The DBA Series, designed for residential applications, is 3-5/8 x 6 in. and is available with one
heating element. The SHA Series, designed for commercial applications, is 5-3/8 x 7 in. and is available with one, two, or three elements. Both
styles are available in two versions: front-in/top-out and bottom-in/top-out.
DIMENSIONS & STANDARD PEDESTAL PLACEMENT
BACK OF HEATER
STANDARD PEDESTAL PLACEMENT
DIMENSIONS
CATALOG NO.
H
W
L
CATALOG NO.
A
B
L
DBA
6”
3-5/8”
28”-15’
DBA
2”
2-1/4”
28”-10’
SHA
7"
3-5/8”
28”-15’
SHA
2”
2-1/4”
28”-12'
NOTE: On units longer than 10 ft., three pedestals are required. Consult factory for placement.
For the latest models and information, please visit our website at www.qmarkmep.com67
CONVECTION HEATERS
MODELS & SPECIFICATIONS | DBA SERIES
CATALOG NO.
LENGTH
(FT)
DBA02
2.3
DBA03
3
DBA04
4
DBA05
5
DBA06
6
DBA07
7
DBA08
8
DBA09
9
DBA10
10
WATTS PER FT.
TOTAL WATTS
120V
208V
240V
277V
347V
600V
100
125
150
188
250
100
125
150
188
250
100
125
150
188
250
100
125
150
188
250
100
125
150
188
250
100
125
150
188
250
100
125
150
188
250
100
125
150
188
250
100
125
150
188
250
200
250
300
376
500
300
375
450
564
750
400
500
600
752
1000
500
625
750
940
1250
600
750
900
1128
1500
700
875
1050
1316
1750
800
1000
1200
1504
2000
900
1125
1350
1692
2250
1000
1250
1500
1880
2500
1.7
2.1
2.5
3.1
4.2
2.5
3.1
3.8
4.7
6.3
3.3
4.2
5.0
6.3
8.3
4.2
5.2
6.3
7.8
10.4
5.0
6.3
7.5
9.4
12.5
-
1.0
1.2
1.4
1.8
2.4
1.4
1.8
2.2
2.7
3.6
1.9
2.4
2.9
3.6
4.8
2.4
3.0
3.6
4.5
6.0
2.9
3.6
4.3
5.4
7.2
3.4
4.2
5.0
6.3
8.4
3.8
4.8
5.8
7.2
9.6
4.3
5.4
6.5
8.1
10.8
4.8
6.0
7.2
9.0
12.0
0.8
1.0
1.3
1.6
2.1
1.3
1.6
1.9
2.4
3.1
1.7
2.1
2.5
3.1
4.2
2.1
2.6
3.1
3.9
5.2
2.5
3.1
3.8
4.7
6.3
2.9
3.6
4.4
5.5
7.3
3.3
4.2
5.0
6.3
8.3
3.8
4.7
5.6
7.1
9.4
4.2
5.2
6.3
7.8
10.4
0.9
1.1
1.4
1.8
1.1
1.4
1.6
2.0
2.7
1.4
1.8
2.2
2.7
3.6
1.8
2.3
2.7
3.4
4.5
2.2
2.7
3.2
4.1
5.4
2.5
3.2
3.8
4.8
6.3
2.9
3.6
4.3
5.4
7.2
3.2
4.1
4.9
6.1
8.1
3.6
4.5
5.4
6.8
9.0
1.4
1.1
1.3
1.6
2.2
1.2
1.4
1.7
2.2
2.9
1.4
1.8
2.2
2.7
3.6
1.7
2.2
2.6
3.3
4.3
2.0
2.5
3.0
3.8
5.0
2.3
2.9
3.5
4.3
5.8
2.6
3.2
3.9
4.9
6.5
2.9
3.6
4.3
5.4
7.2
1.3
1.7
1.0
1.3
1.6
2.1
1.0
1.3
1.5
1.9
2.5
2.9
1.3
1.7
2.0
2.5
3.3
2.8
3.8
1.7
2.1
2.5
3.1
4.2
SHIP WT. (LBS)
8
10
13
17
20
24
27
30
33
NOTE: Cabinet available up to 15 ft. length. Custom length cabinets are priced with heater and blank to the next larger size. Backs are provided standard with no finish. For finished backs, add 10% to list
price. Knockouts on back omitted by request only. All models are NON-STOCK made-to-order. When ordering, specify quantity, catalog number, voltage, wattage, optional controls, and color. Consult sales
representative for lead times.
68
CONVECTION HEATERS
BLANK SECTIONS & ACCESSORIES | DBA SERIES
CATALOG NO.
DBABS1F
DBABS1B
DBABS2F
DBABS2B
DBABS3F
DBABS3B
DBABS4F
DBABS4B
DBABS5F
DBABS5B
DBABS6F
DBABS6B
DBABS7F
DBABS7B
DBABS8F
DBABS8B
DBABS9F
DBABS9B
DBABS10F
DBABS10B
DIMENSIONS
(W x H x L)
3-5/8” x 6” x 1’
3-5/8” x 6” x 28”
3-5/8” x 6” x 3’
3-5/8” x 6” x 4’
3-5/8” x 6” x 5’
3-5/8” x 6” x 6’
3-5/8” x 6” x 7’
3-5/8” x 6” x 8’
3-5/8” x 6” x 9’
3-5/8” x 6” x 10’
INLET
Front
Bottom
Front
Bottom
Front
Bottom
Front
Bottom
Front
Bottom
Front
Bottom
Front
Bottom
Front
Bottom
Front
Bottom
Front
Bottom
SHIP WT.
(LBS)
4
7
CATALOG NO.
DESCRIPTION
DBAECL
End Cap - Left
DBAECR
End Cap - Right
DBAECLS
End Cap w/Screws - Left
DBAECRS
End Cap w/Screws - Right
ADDT’L WALL SPACE
REQUIRED (IN)
SHIP WT.
(LBS)
1/8
1
DBAICF
Inside Corner-Front In
8-1/2
5
DBAICB
Inside Corner-Bottom In
8-1/2
5
DBAOCF
Outside Corner-Front In
5
4
12
DBAOCB
Outside Corner-Bottom In
5
4
DBA135ICF
135° Inside Corner-Fnt. In
8-1/2
5
16
DBA135ICB
135° Inside Corner-Bot. In
8-1/2
5
DBA135OCF
135° Outside Corner-Fnt. In
5
4
DBA135OCB
135° Outside Corner-Bot. In
5
4
DBADESBL
Dec. End Section-Bot. In, Left
DBADESBR
Dec. End Section-Bot. In, Right
9
19
22.5
24
27
30
NOTE: Blank section grilles are not punched unless requested.
*One pedestal. Two required on units up to 10 ft., three required on units over 10ft.
Add suffix -P for painted, -C for clear anodized, -B for bronze anodized
(excludes PK3S - Black only).
DBADESFL
Dec. End Section-Fnt. In, Left
DBADESFR
Dec. End Section-Fnt. In, Right
5
9-9/64
5
4
4
DBASP
Splice Plate
0 - 1/4
1
DBAFL3
Filler Section 3 in.
0-3
1
DBAFL6
Filler Section 6 in.
3-6
1
DBAFL9
Filler Section 9 in.
6-9
1
DBAFL12
Filler Section 12 in.
9 - 12
1
15 - 18
1.5
4-1/2
1.5
4-1/2
2
DBA-FL18
Filler Section 18 in.
DBADRF
Receptacle Section-Fnt. In
DBADRB
Receptacle Section-Bot. In
DBAPEF
Pneu/Ele Sw-Fnt. In
DBAPEB
Pneu/Ele Sw-Bot. In
PK3S*
Standard Pedestal 2-7/8 in. (H)
-
2
PK3A*
Architectural Pedestal 2-7/8 in. (H)
-
2
SO1A
Stand-Off Bracket
-
1
For the latest models and information, please visit our website at www.qmarkmep.com69
CONVECTION HEATERS
MODELS & SPECIFICATIONS | SHA SERIES
CATALOG NO
LENGTH
(FT)
SHA02
2.3
SHA03
3
SHA04
4
SHA05
5
SHA06
6
SHA07
7
SHA08
8
SHA09
9
SHA10
10
WATTS PER FT.
TOTAL WATTS
120V
208V
240V
277V
347V
600V
100
125
150
188
250
100
125
150
188
250
100
125
150
188
250
100
125
150
188
250
100
125
150
188
250
100
125
150
188
250
100
125
150
188
250
100
125
150
188
250
100
125
150
188
250
200
250
300
376
500
300
375
450
564
750
400
500
600
752
1000
500
625
750
940
1250
600
750
900
1128
1500
700
875
1050
1316
1750
800
1000
1200
1504
2000
900
1125
1350
1692
2250
1000
1250
1500
1880
2500
1.7
2.1
2.5
3.1
4.2
2.5
3.1
3.8
4.7
6.3
3.3
4.2
5.0
6.3
8.3
4.2
5.2
6.3
7.8
10.4
5.0
6.3
7.5
9.4
12.5
-
1.0
1.2
1.4
1.8
2.4
1.4
1.8
2.2
2.7
3.6
1.9
2.4
2.9
3.6
4.8
2.4
3.0
3.6
4.5
6.0
2.9
3.6
4.3
5.4
7.2
3.4
4.2
5.0
6.3
8.4
3.8
4.8
5.8
7.2
9.6
4.3
5.4
6.5
8.1
10.8
4.8
6.0
7.2
9.0
12.0
0.8
1.0
1.3
1.6
2.1
1.3
1.6
1.9
2.4
3.1
1.7
2.1
2.5
3.1
4.2
2.1
2.6
3.1
3.9
5.2
2.5
3.1
3.8
4.7
6.3
2.9
3.6
4.4
5.5
7.3
3.3
4.2
5.0
6.3
8.3
3.8
4.7
5.6
7.1
9.4
4.2
5.2
6.3
7.8
10.4
0.9
1.1
1.4
1.8
1.1
1.4
1.6
2.0
2.7
1.4
1.8
2.2
2.7
3.6
1.8
2.3
2.7
3.4
4.5
2.2
2.7
3.2
4.1
5.4
2.5
3.2
3.8
4.8
6.3
2.9
3.6
4.3
5.4
7.2
3.2
4.1
4.9
6.1
8.1
3.6
4.5
5.4
6.8
9.0
1.4
1.1
1.3
1.6
2.2
1.2
1.4
1.7
2.2
2.9
1.4
1.8
2.2
2.7
3.6
1.7
2.2
2.6
3.3
4.3
2.0
2.5
3.0
3.8
5.0
2.3
2.9
3.5
4.3
5.8
2.6
3.2
3.9
4.9
6.5
2.9
3.6
4.3
5.4
7.2
1.3
1.7
1.0
1.3
1.6
2.1
1.0
1.3
1.5
1.9
2.5
2.9
1.3
1.7
2.0
2.5
3.3
2.8
3.8
1.7
2.1
2.5
3.1
4.2
SHIP WT. (LBS)
8
10
13
17
20
24
27
30
33
NOTE: Cabinet available up to 12 ft. length. Custom length cabinets are priced with heater and blank to the next larger size. Backs are provided standard with no finish. For finished backs, add 10% to list
price. Knockouts on back omitted by request only. All models are NON-STOCK made-to-order. When ordering, specify quantity, catalog number, voltage, wattage, optional controls, and color. Consult sales
representative for lead times.
70
CONVECTION HEATERS
MODELS & SPECIFICATIONS | SHA SERIES MULTIPLE-ELEMENT UNITS
CATALOG NO
LENGTH
(FT)
SHA02
2.3
SHA03
3
SHA04
4
SHA05
5
SHA06
6
SHA07
7
SHA08
8
SHA09
9
SHA10
10
208V
240V
277V
347V
600V
WATTS
PER FT.
TOTAL
WATTS
(1 PH / 3 PH)
(1 PH / 3 PH)
(1 PH)
(1 PH)
(1 PH / 3 PH)
375
500
600
750*
375
500
600
750*
375
500
600
750*
375
500
600
750*
375
500
600
750*
375
500
600
750*
375
500
600
750*
375
500
600
750*
375
500
600
750*
750
1000
1200
1500
1125
1500
1800
2250
1500
2000
2400
3000
1875
2500
3000
3750
2250
3000
3600
4500
2625
3500
4200
5250
3000
4000
4800
6000
3375
4500
5400
6750
3750
5000
6000
7500
3.6 / 4.8 / 5.8 / 3.3
7.2 / 4.2
5.4 / 7.2 / 8.7 / 5.0
10.8 / 6.3
7.2 / 9.6 / 11.5 / 6.7
14.4 / 8.3
9.0 / 12.0 / 14.4 / 8.3
18.0 / 10.4
10.8 / 14.4 / 17.3 / 10.0
21.6 / 12.5
12.6 / 16.8 / 20.2 / 11.7
25.2 / 14.6
14.4 / 19.2 / 23.1 / 13.3
28.8 / 16.7
16.2 / 21.6 / 26.0 / 15.0
32.5 / 18.8
18.0 / 24.0 / 28.8 / 16.7
36.1 / 20.8
3.1 / 4.2 / 5.0 / 2.9
6.3 / 3.6
4.7 / 6.3 / 7.5 / 4.3
9.4 / 5.4
6.3 / 8.3 / 10.0 / 5.8
12.5 / 7.2
7.8 / 10.4 / 12.5 / 7.2
15.6 / 9.0
9.4 / 12.5 / 15.0 / 8.7
18.8 / 10.8
10.9 / 14.6 / 17.5 / 10.1
21.9 / 12.6
12.5 / 16.7 / 20.0 / 11.6
25.0 / 14.5
14.1 / 18.8 / 22.5 / 13.0
28.1 / 16.3
15.6 / 20.8 / 25.0 / 14.5
31.3 / 18.1
2.7
3.6
4.3
5.4
4.1
5.4
6.5
8.1
5.4
7.2
8.7
10.8
6.8
9.0
10.8
13.5
8.1
10.8
13.0
16.2
9.5
12.6
15.2
19.0
10.8
14.4
17.3
21.7
12.2
16.2
19.5
24.4
13.5
18.1
21.7
27.1
2.9
4.3
4.3
6.5
4.3
5.8
6.9
8.6
5.4
7.2
8.6
10.8
6.5
8.6
10.4
13.0
7.6
10.1
12.1
15.1
8.6
11.5
13.8
17.3
9.7
13.0
15.6
19.5
10.8
14.4
17.3
21.6
3.3 / 5.0 / 2.9
3.1 / 4.2 / 5.0 / 2.9
6.3 / 3.6
3.8 / 5.0 / 6.0 / 3.5
7.5 / 4.3
5.8 / 8.8 / 5.1
5.0 / 6.7 / 8.0 / 4.6
10.0 / 5.8
5.6 / 7.5 / 9.0 / 5.2
11.3 / 6.5
6.3 / 8.3 / 10.0 / 5.8
12.5 / 7.2
NO. OF
ELEMENTS
SHIP WT.
(LBS)
3
3
12
2
3
15.5
2
3
20
2
3
25.5
2
3
30
2
3
35
2
3
40
2
3
45
2
3
50
NOTE: *750W models have bottom inlet only
Cabinet available up to 12 ft. length. Custom length cabinets are priced with heater and blank to the next larger size. Backs are provided standard with no finish. For finished backs, add 10% to list price.
Knockouts on back omitted by request only. All models are NON-STOCK made-to-order. When ordering, specify quantity, catalog number, voltage, wattage, optional controls, and color. Consult sales
representative for lead times.
For the latest models and information, please visit our website at www.qmarkmep.com71
CONVECTION HEATERS
BLANK SECTIONS & ACCESSORIES | SHA SERIES
CATALOG NO.
SHABS1F
SHABS1B
SHABS2F
SHABS2B
SHABS3F
SHABS3B
SHABS4F
SHABS4B
SHABS5F
SHABS5B
SHABS6F
SHABS6B
SHABS7F
SHABS7B
SHABS8F
SHABS8B
SHABS9F
SHABS9B
SHABS10F
SHABS10B
DIMENSIONS
(W x H x L)
5-3/8” x 7” x 1’
5-3/8” x 7” x 28”
5-3/8” x 7” x 3’
5-3/8” x 7” x 4’
5-3/8” x 7” x 5’
5-3/8” x 7” x 6’
5-3/8” x 7” x 7’
5-3/8” x 7” x 8’
5-3/8” x 7” x 9’
5-3/8” x 7” x 10’
INLET
Front
Bottom
Front
Bottom
Front
Bottom
Front
Bottom
Front
Bottom
Front
Bottom
Front
Bottom
Front
Bottom
Front
Bottom
Front
Bottom
SHIP WT.
(LBS)
7
11
14
18
DESCRIPTION
SHAECL
End Cap - Left
SHAECR
End Cap - Right
SHAECLS
End Cap w/Screws - Left
SHAECRS
End Cap w/Screws - Right
ADDT’L WALL SPACE
REQUIRED (IN)
SHIP WT.
(LBS)
1/8
1
SHAICF
Inside Corner-Front In
10
11
SHAICB
Inside Corner-Bottom In
10
11
SHAOCF
Outside Corner-Front In
5
7
SHAOCB
Outside Corner-Bottom In
5
7
SHA135ICF
135° Inside Corner-Fnt. In
10
11
22
SHA135ICB
135° Inside Corner-Bot. In
10
11
SHA135OCF
135° Outside Corner-Fnt. In
5
7
27
SHA135OCB
135° Outside Corner-Bot. In
5
SHADESBL
Dec. End Section-Bot. In, Left
SHADESBR
Dec. End Section-Bot. In, Right
SHADESFL
Dec. End Section-Fnt. In, Left
SHADESFR
Dec. End Section-Fnt. In, Right
32
37
40
44
NOTE: Blank section grilles are not punched unless requested.
*One pedestal. Two required on units up to 10 ft., three required on units over 10ft.
Add suffix -P for painted, -C for clear anodized, -B for bronze anodized
(excludes PK5S - Black only).
72
CATALOG NO.
7
11
12-1/2
11
7
7
SHASP
Splice Plate
0 - 1/4
1
SHAFL3
Filler Section 3 in.
0-3
1
SHAFL6
Filler Section 6 in.
3-6
1
SHAFL9
Filler Section 9 in.
6-9
2
SHAFL12
Filler Section 12 in.
9 - 12
3
SHA-FL18
Filler Section 18 in.
15 - 18
5
4-1/2
2
SHADRF
Receptacle Section-Fnt. In
SHADRB
Receptacle Section-Bot. In
PK5S*
Standard Pedestal 4-1/8 in. (H)
-
2
PK5A*
Architectural Pedestal 4-1/8 in. (H)
-
2
SO1A
Stand-Off Bracket
-
1
CONVECTION HEATERS
OPTIONAL BUILT-IN CONTROLS | DBA & SHA SERIES
SUFFIX ADDITION TO
BASIC CATALOG NO.
see page 98 for additional controls
OPTIONAL BUILT-IN
CONTROL
RATINGS & DESCRIPTIONS
T
Single-Pole
Thermostat
Rated 24 amps @ 120-240 VAC and 22 amps @ 277 VAC. Pilot duty rating of 125 VA (all voltages). 60-120°F temperature
range; adjustable through outlet grille-tamper-resistant. (See Note B) Not available on three-phase heaters.
2T
Double-Pole
Thermostat
DS
Power On/Off Switch
Rated 24 amps @ 120-240 VAC and 22 amps @ 277 VAC. Pilot duty rating of 125 VA (all voltages). 60-120°F temperature
range; adjustable through outlet grille-tamper-resistant. (See Note B for amperage restrictions.)
Double-pole, rated 20 amp @ 120-277 VAC. (See Note A)
For three-phase heaters and single-phase heaters over 20 amps specify two.
TR
Transformer Relay
Single-pole, low voltage relay with built-in transformer (24 VAC control), rated 22 amps @ 120-240 VAC and
22 amps @ 277 VAC. (See note E) 17 amps @ 347V. Not available on three-phase heaters.
PR
Power Relay
Single-pole thermal time delay relay, rated 25 amps @ 120-600 VAC. (See Notes E & F). Specify control voltage.
2ST
2-Stage Thermostat
Rated 24 amps @ 120-240 VAC and 22 amps @ 277 VAC. Pilot duty rating of 125 VA (all voltages). 60-120°F temperature
range, adjustable through outlet grille-tamper-resistant. Available on 2- or 3-element, single-phase heaters only.
PE
Pneumatic/Electric
Switch
Pressure set-point @ 10 PSIG adjustable to 30 PSIG. Can be set to “make” or “break” on pressure drop.
Rated 25 amps @ 120-277 VAC. (See Note G)
(SEE NOTE D)
Single-Pole
Thermostat
Double-Pole
Thermostat
Outlet Mesh
PDT
2TPD
M
Same as -T except Pilot Duty. (See Note C)
Same as -2T except Pilot Duty. (See Note C & D)
Price per foot
A
0
8
5
0
B
2
0
3
C
HOW TO ORDER
CONVECTION
HEATERS DBA & SHA SERIES
CONTROLS
VOLTS
INLET AIR CONFIG.
0
UNIT DESIGNATION
H
NO. OF PHASES
S
WATT DENSITY
PRODUCT
CABINET LENGTH
NOTE:
A. For single-phase loads over 20A and all three-phase loads, specify (2) power on/off switches.
B. This control option is not available on single-phase heaters over 24 amps (22 amps on 277 VAC). In combination with the power on/off switch option use the 2ST thermostat option on heaters over 20 amps.
C. A second transformer relay can be sequenced off the first transformer relay in the same heater. Up to 30 power relays in different heaters can be controlled by (1) single-stage pilot duty thermostat.
D. Up to 30 power relays in different heater can be controlled by each stage of a two-stage pilot duty thermostat.
E. Two relays are required on single-phase heaters over 20 amps with a power on/off switch, over 25 amps without a power on/off and on all three-phase heaters. Two relays are available for two-stage on two- or
three-element heaters only.
F. Three power relays are available for three-stage on three-element heaters only.
G. Fits in SHA unit only. For DBA, PE will be installed in 4-1/2 in. section.
D
S
2
S
T
T=
Single-Pole Thermostats
2T = Double-Pole Thermostats
DS = Power On/Off Switch
TR = Transformer Relay
PR = Power Relay
PE = Pneumatic/Electric Switch
2ST = Two-stage thermostat
Series Name
02
04
06
08
10
=
=
=
=
=
2.3 ft.
4 ft.
6 ft.
8 ft.
10 ft.
03
05
07
09
=
=
=
=
3
5
7
9
ft.
ft.
ft.
ft.
[DBA] 100 w/ft., 125 w/ft., 150 w/ft.,
188 w/ft., 250 w/ft.
[SHA] include all DBA watt densities plus
375 w/ft., 500 w/ft., 600 w/ft. and 750 w/
ft. (bottom inlet only).
S - Standard Unit: Cabinet is the same length as heat deck.
C - Custom Unit: Cabinet longer than heat deck (e.g. 6 ft. heat deck in a 7 ft. 3 in.
cabinet) or multiple heat decks in single cabinet (e.g. 3 ft. and 28 in. heat deck in
an 8 ft. 6 in. cabinet). Custom units require use of Custom Convector Layout Form
to detail the unit for order entry.
1= single-phase | 3 = three-phase
B = Bottom Inlet
F = Front Inlet
12 = 120V; 20 = 208V | 24 = 240V; 27 = 277V
For the latest models and information, please visit our website at www.qmarkmep.com73
CONVECTION HEATERS
SLIMLINE ALUMINUM CONVECTOR
DBSL SERIES
AVAILABLE COLORS
Navajo Northern Charcoal
White
White
Gray
Neutral
Gray
NAVAJO
WHITE
Custom
Colors
Statuary
Bronze
Desert
Tan
Gloss
Black
Aluminum
IDEAL SPACES | Offices; Hallways; Lobbies; Conference Rooms; Condos; Retail; Other Areas with Floor-to-Ceiling Windows
COLORS | Neutral Gray; Charcoal Gray; Navajo White; Northern White; Statuary Bronze; Desert Tan; Black;
Custom Colors, Baked Enamel and Anodized Finishes Available
DIMENSIONS | 6" H x 2-3/4"D (Length varies)
•
Approved for residential applications
•
Ideal for elegant, supplemental comfort under
windows for heat loss and condensation prevention
•
Unique two-piece extruded aluminum “Snap-Lock”
closure design secures the one-piece top and front
grilles to the one-piece back and bottom providing
a rapid, secure fit all along the length of the unit
•
Front/bottom inlet air grille utilizes slots which create
an attractive installation where inlet grille is visible
•
Unit comes standard with rear knockouts and
unpainted back. Optional custom-painted backs
and rear knockout options are available
•
Blend into any décor with custom paint and anodizing
upon request
•
Units can be mounted on floor, wall, or pedestals
•
Customize space with wall-to-wall installation, or as
discrete units in standard lengths of 2-10 ft.
•
Units are available in a wide range of heating
capacities per foot length (see specification charts)
•
Inside and outside corners can be ordered factory-cut
and mitered to fit difficult or unusual spaces
Bottom inlet unit is only 2-3/4 in.
wide by 6 in. tall. Can be mounted
to wall (3 in. above floor) or in front
of window mounted on pedestals.
74
•
Architectural-style end sections give a finished look
when used as a stand-alone or where a wall-to-wall run
is not desired
•
Full line of trim accessories, including matching blank
sections, end caps, filler sections, inside and outside
corners, diagonal end sections, and splice plates
•
Optional built-in controls include: line-voltage
thermostat; two-stage thermostat; on/off switch;
transformer relay; power relay and pneumatic/switch
•
Right -or left-hand entry and built-in wire way
(equivalent to 1/2 in. conduit) with factory-installed wiring
•
Easy connection of supply wiring from bottom, rear or
end, as well as multiple wiring of adjacent heaters from
one entry point
•
Thermal limit switch with linear type (full length)
sensing bulb provides constant protection against
overheating from any cause
•
Switch will automatically reset when normal
operating temperatures are restored
•
Discharge air openings in top grille are punched
slots which are pencil-proof for safety
Front inlet unit is only 2-¾ in.
wide by 6 in. tall. Can be mounted
to wall or directly to floor.
Hollow pedestals are 3 in. tall
and allow concealed wiring
access when stubbed through
concrete floors.
CONVECTION HEATERS
MODELS & SPECIFICATIONS
CATALOG
NO.
DBSL01
DBSL02
DBSL03
LENGTH (FT)
2
2.3
3
DBSL04
4
DBSL05
5
DBSL06
6
BLANK SECTIONS & ACCESSORIES
SHIP WT.
(LBS)
VOLTS
WATTS/FT. OPTIONS
120
208
220
240
277
120
208
220
240
277
347
120
208
220
240
277
347
120
208
220
240
277
347
600
120
208
220
240
277
347
600
120
208
220
240
277
347
600
188
150; 188
125
150; 188; 250
188; 250
100; 125; 150; 188; 250
100; 125; 150; 188; 250
100; 125; 188
100; 125; 150; 188; 250
125; 150; 188; 250
250
100; 125; 150; 188; 250
100; 125; 150; 188; 250
100; 125; 250
100; 125; 150; 188; 250
100; 125; 150; 188; 250
125; 150; 188; 250
100; 125; 150; 188; 250
100; 125; 150; 188; 250
100; 125; 150; 188; 250
100; 125; 150; 188; 250
100; 125; 150; 188; 250
100; 125; 150; 188; 250
188; 250
100; 125; 150; 188; 250
100; 125; 150; 188; 250
100; 125; 150; 250
100; 125; 150; 188; 250
100; 125; 150; 188; 250
125; 150; 188; 250
125; 150; 188; 250
100; 125; 150; 188; 250
100; 125; 150; 188; 250
100; 125; 150; 250
100; 125; 150; 188; 250
100; 125; 150; 188; 250
125; 150; 188; 250
100; 125; 150; 188; 250
8
8
10
13
17
20
NOTE: Additional cabinet sizes available up to 12 ft. length. Backs are provided
standard with no finish. For finished backs, add 10% to list price. Knockouts on back
omitted by request only. All models are non-stock, made-to-order. Consult sales
representative for more information on specs and lead times.
CATALOG NO.
(See Note 1)
SLCBS1F
SLCBS1B
SLCBS2F
SLCBS2B
SLCBS3F
SLCBS3B
SLCBS4F
SLCBS4B
SLCBS5F
SLCBS5B
SLCBS6F
SLCBS6B
DIMENSIONS
WxHxL
2-3/4” x 6” x 1’
2-3/4” x 6” x 28”
2-3/4” x 6” x 3’
2-3/4” x 6” x 4’
2-3/4” x 6” x 5’
2-3/4” x 6” x 6’
INLET
Front
Bottom
Front
Bottom
Front
Bottom
Front
Bottom
Front
Bottom
Front
Bottom
SHIP WT.
(LBS)
4
7
9
12
16
19
NOTE: Blank section grilles are not punched unless requested. Additional sections available for
cabinets up to 12 ft. length.
CATALOG
NO.*
DESCRIPTION
SLCECL
SLCECR
SLCICF
SLCICB
SLCOCF
SLCOCB
SLCDESBL
SLCDESBR
SLCDESFL
SLCDESFR
SLCSP
SLCFL3
SLCFL6
SLCFL9
SLCFL12
SLCFL18
SLCFL24
SLCDRF
SLCDRB
SLCPEF
SLCPEB
SLCPK3A**
SO1A
End Cap - Left
End Cap - Right
Inside Corner-Front In
Inside Corner-Bottom In
Outside Corner-Front In
Outside Corner-Bottom In
Dec. End Section-Bot. In, Left
Dec. End Section-Bot. In, Right
Dec. End Section-Fnt. In, Left
Dec. End Section-Fnt. In, Right
Splice Plate
Filler Section 3 in.
Filler Section 6 in.
Filler Section 9 in.
Filler Section 12 in.
Filler Section 18 in.
Filler Section 24 in.
Receptacle Section-Fnt. In
Receptacle Section-Bot. In
Pneu/Ele Sw-Fnt. In
Pneu/Ele Sw-Bot. In
Architectural Pedestal
Stand-Off Bracket
ADDT’L
WALL SPACE
REQUIRED (IN)
1/8
1/8
8 - 1/2
8 - 1/2
5
5
9 - 9/64
9 - 9/64
9 - 9/64
9 - 9/64
0 - 1/4
0-3
3-6
6-9
9 - 12
12 - 18
18 - 24
4 - 1/2
4 - 1/2
4 - 1/2
4 - 1/2
–
–
SHIP WT.
(LBS)
1
1
5
5
4
4
5
5
4
4
1
1
1
1
1
1.5
1.5
1.5
1.5
2
2
2
1
NOTE: *Add suffix -P for painted, -C for clear anodized, -B for bronze anodized. **One pedestal. Two
pedestals required on units up to 10 ft. and three required on units over 10 ft.
OPTIONAL BUILT-IN CONTROLS
SUFFIX ADDITION TO
CATALOG NO. (SEE NOTE D)
OPTIONAL BUILT-IN
CONTROLS
RATINGS & DESCRIPTIONS
T
Single-Pole Thermostat
Rated 24 amps @ 120-240 VAC and 22 amps @ 277 VAC. Pilot duty rating of 125 VA (all voltages)
60-120°F temperature range adjustable through outlet grille-tamper-resistant. (See Note B)
2T
Double-Pole Thermostat
Rated 24 amps @ 120-240 VAC and 22 amps @ 277 VAC. Pilot duty rating of 125 VA (all voltages). 60-120°F
temperature range adjustable through outlet grille-tamper-resistant. (See Note B for amperage restrictions)
DS
Power On/Off Switch
Double-pole, rated 20 amp @ 120-277 VAC. (See Note A.) For heaters over 20 amps specify two
TR*
Transformer Relay
PR
Power Relay
Single-pole, low voltage relay with built-in transformer (24 VAC control), rated 25 amps @ 120-240 VAC and 22
amps @ 277 VAC. (See Note E and F) 17 amps @ 347V. Not available for three-phase heaters
Single-pole magnetic relay, rated 25 amps @ 120-600 VAC. (See Note E). Specify control voltage
PE*
Pneumatic / Electric
Pressure set-point @ 10 PSIG adjustable to 30 PSIG. Can be set to “make” or “break” on pressure drop
PDT
R*
Switch
Single-Pole Thermostat
Receptacle
Rated 25 amps @ 120-277 VAC. (See Note F)
Same as -T except Pilot Duty. (See Note C)
For built-in or as installed in a control section
NOTES: *Will add 4 in. to length of heater. (A) For single-phase loads over 20A, specify (2) power on/off switches. (B) This control option is not available on single-phase heaters over 24 amps (22 amps on
277 VAC). In combination with the power on/off switch option use the 2T thermostat option on heaters over 20 amps. (C) Requires PR or TR. (D) Up to 30 power relays in different heaters can be controlled
by each stage of a two-stage pilot duty thermostat. (E) Two relays are required on single-phase heaters over 20 amps with a disconnect switch, over 25 amps without a disconnect switch. (F) For DBSL
Series the TR (tranformer relay) R (Duplex Receptacle) PE (Pneumatic switch) will be installed in separate 4 in. long internal control boxes.
FOR INFORMATION ON HOW TO ORDER THE DBSL SERIES, SEE PAGE 78.
For the latest models and information, please visit our website at www.qmarkmep.com75
CONVECTION HEATERS
DRAFT BARRIER CONVECTOR
SLQDB SERIES
AVAILABLE COLORS
Navajo Northern Charcoal
White
White
Gray
Neutral
Gray
Custom
Colors
Statuary
Bronze
Desert
Tan
Gloss
Black
GLOSS BLACK
Aluminum
IDEAL SPACES | Offices; Hallways; Lobbies; Conference Rooms; Retail; Other Similar Areas with Floor-to-Ceiling Windows
COLORS | Neutral Gray; Charcoal Gray; Navajo White; Northern White; Statuary Bronze; Desert Tan; Black;
Custom Colors, Baked Enamel and Anodized Finishes Available
DIMENSIONS | 4" H x 2-5/8" D (Length varies)
•
Ideal for elegant, supplemental comfort under
windows for heat loss and condensation prevention
•
•
Unique two-piece extruded aluminum “Snap-Lock”
closure design secures the one-piece top and front
grilles to the one-piece back and bottom providing
a rapid, secure fit all along the length of the unit
Architectural-style end sections give a finished look
when used as a stand-alone or where a wall-to-wall run
is not desired
•
Full line of trim accessories, including matching blank
sections, end caps, filler sections, inside and outside
corners, diagonal end sections, and splice plates
•
Front/bottom inlet air grille utilizes slots which create
an attractive installation where inlet grille is visible
•
•
Unit comes standard with rear knockouts and
unpainted back. Optional custom-painted backs
and rear knockout options are available
Optional built-in controls include: line-voltage
thermostat; two-stage thermostat; on/off switch;
transformer relay; power relay and pneumatic/switch
•
Right -or left-hand entry and built-in wire way
(equivalent to 1/2 in. conduit) with factory-installed wiring
•
Blend into any décor with custom paint and anodizing
upon request
•
•
Units can be mounted on floor, wall, or pedestals
Easy connection of supply wiring from bottom, rear or
end, as well as multiple wiring of adjacent heaters from
one entry point
•
Customize space with wall-to-wall installation, or as
discrete units in standard lengths of 2-10 ft.
•
•
Single or multiple heat decks are available upon
request to accommodate a multitude of spaces
Thermal limit switch with linear type (full length)
sensing bulb provides constant protection against
overheating from any cause
•
•
Units are available in a wide range of heating
capacities per foot length (see specification charts)
Switch will automatically reset when normal
operating temperatures are restored
•
•
Inside and outside corners can be ordered factory-cut
and mitered to fit difficult or unusual spaces
Discharge air openings in top grille are punched
slots which are pencil-proof for safety
Bottom inlet unit is only 2-5/8 in.
wide by 4 in. tall. Can be mounted
to wall (2 in. above floor) or in front
of window mounted on pedestals.
76
Hollow pedestals are 3 in. tall
and allow concealed wiring
access when stubbed through
concrete floors.
CONVECTION HEATERS
MODELS & SPECIFICATIONS
CATALOG
NO.
SLQDB024
SLQDB028
SLQDB03
LENGTH (FT)
2
2.3
3
SLQDB04
4
SLQDB05
5
SLQDB06
6
BLANK SECTIONS & ACCESSORIES
VOLTS
WATTS/FT. OPTIONS
120
208
220
240
277
120
208
220
240
277
347
120
208
220
240
277
347
120
208
220
240
277
347
600
120
208
220
240
277
347
600
120
208
220
240
277
347
600
188
150; 188
125
150; 188; 250
188; 250
100; 125; 150; 188; 250
100; 125; 150; 188; 250
100; 125; 188
100; 125; 150; 188; 250
125; 150; 188; 250
250
100; 125; 150; 188; 250
100; 125; 150; 188; 250
100; 125; 250
100; 125; 150; 188; 250
100; 125; 150; 188; 250
125; 150; 188; 250
100; 125; 150; 188; 250
100; 125; 150; 188; 250
100; 125; 150; 188; 250
100; 125; 150; 188; 250
100; 125; 150; 188; 250
100; 125; 150; 188; 250
188; 250
100; 125; 150; 188; 250
100; 125; 150; 188; 250
100; 125; 150; 250
100; 125; 150; 188; 250
100; 125; 150; 188; 250
125; 150; 188; 250
125; 150; 188; 250
100; 125; 150; 188; 250
100; 125; 150; 188; 250
100; 125; 150; 250
100; 125; 150; 188; 250
100; 125; 150; 188; 250
125; 150; 188; 250
100; 125; 150; 188; 250
SHIP WT.
(LBS)
8
8
CATALOG NO.
(See Note 1)
DIMENSIONS
WxHxL
SHIP WT.
(LBS)
SLDBS1B
2-5/8” x 4” x 1’
4
SLDBS2B
2-5/8” x 4” x 28”
7
SLDBS3B
2-5/8” x 4” x 3’
9
SLDBS4B
2-5/8” x 4” x 4’
12
SLDBS5B
2-5/8” x 4” x 5’
16
SLDBS6B
2-5/8” x 4” x 6’
19
NOTE: Blank section grilles are not punched unless requested. Additional sections available for
cabinets up to 12 ft. length.
10
13
17
20
NOTE: Additional cabinet sizes available up to 12 ft. length. Backs are provided
standard with no finish. For finished backs, add 10% to list price. Knockouts on back
omitted by request only. All models are non-stock, made-to-order. Consult sales
representative for more information on specs and lead times.
CATALOG
NO.*
DESCRIPTION
SLDECL
SLDECR
SLDICF
SLDICB
SLDOCF
SLDOCB
SLDDESBL
SLDDESBR
SLDDESFL
SLDDESFR
SLDSP
SLDFL3
SLDFL6
SLDFL9
SLDFL12
SLDFL18
SLDFL24
SLDDRF
SLDDRB
SLDPEF
SLDPEB
SLDPK3A**
SO1A
End Cap - Left
End Cap - Right
Inside Corner-Front In
Inside Corner-Bottom In
Outside Corner-Front In
Outside Corner-Bottom In
Dec. End Section-Bot. In, Left
Dec. End Section-Bot. In, Right
Dec. End Section-Fnt. In, Left
Dec. End Section-Fnt. In, Right
Splice Plate
Filler Section 3 in.
Filler Section 6 in.
Filler Section 9 in.
Filler Section 12 in.
Filler Section 18 in.
Filler Section 24 in.
Receptacle Section-Fnt. In
Receptacle Section-Bot. In
Pneu/Ele Sw-Fnt. In
Pneu/Ele Sw-Bot. In
Architectural Pedestal
Stand-Off Bracket
ADDT’L
WALL SPACE
REQUIRED (IN)
1/8
1/8
8 - 1/2
8 - 1/2
5
5
9 - 9/64
9 - 9/64
9 - 9/64
9 - 9/64
0 - 1/4
0-3
3-6
6-9
9 - 12
12 - 18
18 - 24
4 - 1/2
4 - 1/2
4 - 1/2
4 - 1/2
–
–
SHIP WT.
(LBS)
1
1
5
5
4
4
5
5
4
4
1
1
1
1
1
1.5
1.5
1.5
1.5
2
2
2
1
NOTE: *Add suffix -P for painted, -C for clear anodized, -B for bronze anodized. **One pedestal. Two
pedestals required on units up to 10 ft. and three required on units over 10 ft.
OPTIONAL BUILT-IN CONTROLS
SUFFIX ADDITION TO
BASIC CATALOG NO.
OPTIONAL BUILT-IN
CONTROL
RATINGS & DESCRIPTIONS
Single-Pole
Thermostat
Rated 24 amps @ 120-240 VAC and 22 amps @ 277 VAC. Pilot duty rating of 125 VA (all voltages). 60-120°F temperature
range; adjustable through outlet grille-tamper-resistant. (See Note B) Not available on three-phase heaters.
DS
Power On/Off Switch
Double-pole, rated 20 amp @ 120-277 VAC. (See Note A) For three-phase heaters and single-phase
heaters over 20 amps specify two.
PR
Power Relay
Single-pole magnetic relay, rated 18 amps @ 120-600 VAC. (See Note C) Specify control voltage.
Rated 24 amps @ 120-240 VAC and 22 amps @ 277 VAC. Pilot duty rating of 125 VA - all voltages (See Note C)
T
NOTE:
A. For single-phase loads over 20A and all three-phase loads, specify (2) power on/off switches.
B. This control option is not available on single-phase heaters over 24 amps (22 amps on 277 VAC).
C. Specify holding coil voltage where applicable.
FOR INFORMATION ON HOW TO ORDER THE SLQDB SERIES, SEE PAGE 79.
For the latest models and information, please visit our website at www.qmarkmep.com77
CONVECTION HEATERS
PRODUCT
NOMINAL UNIT LENGTH (FT)
WATTS/FT
INLET
VOLTAGE
LAYOUT
FRONT/BACK PAINT
OPTIONS
CONTROL LOCATION
THERMOSTAT
DISCONNECT SWITCH
POWER RELAY
TRANSFORMER RELAY
DUPLEX RECEPTACLE
PNEUMATIC SWITCH
DWO
HOW TO ORDER CONVECTION HEATERS - DBSL SERIES
DBSL
12
250
F
20
C
BB
3
R
T
D
0
X
0
0
D
Convection Heater
01
02
03
04
05
06
=
=
=
=
=
=
2 ft.
2.3 ft.
3 ft.
4 ft.
5 ft.
6 ft.
100
125
150
07
08
09
10
11
12
= 7 ft.
= 8 ft.
= 9 ft.
- 10 ft.
= 11 ft.
= 12 ft.
0 = None
D = DWO (Designated Work Order for
custom finishes, controls, etc.)
0 = None
U = Pneumatic Switch (requires DWO)*
188
250
*Adds 4 in. to length of unit.
F = Front Inlet Air Configuration
(also equals dual inlet
B = Bottom Inlet Air Configuration
12
20
22
24
=
=
=
=
120V
208V
220V
240V
0 = None
X = Transformer Relay*
C = Custom: Heat deck locations determined
by the representative using custom layout form.
Control locations must be accounted for in layout
(see Control Location notes).
M = Mill
C = Clear Anodized
Z = Bronze Anodized
K = Black Anodized
G = Charcoal Gray
B = Black
P = Navajo White
78
=
=
=
=
None
Pedestals
End Caps
Both
*Adds 4 in. to length of unit.
27 = 277V
34 = 347V
60 = 600V
S = Standard: Heat deck and control locations
determined by the factory.
0
1
2
3
0 = None
R = Duplex Receptacle*
A = Aluminum
S = Statuary Bronze
N = Neutral Gray
T = Desert Tan
W = Northern White
U = Custom (Requires DWO)
End caps (2) will have same finish as
front cover. Pedestal quantity will vary
based on length of unit. All options will
ship in same carton as the unit.
*Provides 24VAC power for external wall thermostat. Adds 4 in.
to length of unit.
0
L
1
2
=
=
=
=
None
Line voltage coil (same as heater voltage)
120VAC holding coil
24VAC holding coil
NOTE: Power relay requires external voltage
0 = None
D = (1) two-pole switch
C = (2) two-pole switches (requires DWO)
0 = None
T = Single-Pole
S = Double-Pole
P = Pilot Duty (requires PR or TR)
L = Left
R = Right
Due to space constraints the disconnect switch and thermostat must always be
mounted on the opposite side of all other controls. Control location and incoming
power connection is determined by the location of the disconnect switch and
thermostat when facing the unit.
CONVECTION HEATERS
PRODUCT
NOMINAL UNIT LENGTH (FT)
WATTS/FT
INLET
VOLTAGE
LAYOUT
FRONT/BACK PAINT
OPTIONS
CONTROL LOCATION
THERMOSTAT
DISCONNECT SWITCH
DWO
HOW TO ORDER CONVECTION HEATERS - SLQDB SERIES
SLQDB
12
188
B
24
S
GG
3
R
T
D
D
Convection Heater
01
02
03
04
05
=
=
=
=
=
2 ft.
2.3 ft.
3 ft.
4 ft.
5 ft.
100
125
150
06
07
08
09
10
= 6 ft.
= 7 ft.
= 8 ft.
= 9 ft.
- 10 ft.
188
250
B=B
ottom Inlet
Air Configuration Only
12
20
22
24
=
=
=
=
120V
208V
220V
240V
27 = 277V
34 = 347V
60 = 600V
S = Standard: Heat deck and control locations
determined by the factory.
C = Custom: Heat deck locations determined
by the representative using custom layout form.
Control locations must be accounted for in layout
(see Control Location notes).
M = Mill
C = Clear Anodized
Z = Bronze Anodized
K = Black Anodized
G = Charcoal Gray
B = Black
P = Navajo White
0
1
2
3
=
=
=
=
None
Pedestals
End Caps
Both
A = Aluminum
S = Statuary Bronze
N = Neutral Gray
T = Desert Tan
W = Northern White
U = Custom (Requires DWO)
End caps (2) will have same finish as
front cover. Pedestal quantity will vary
based on length of unit. All options will
ship in same carton as the unit.
0 = None
D = DWO (Designated Work Order for
custom finishes, controls, etc.)
0 = None
0 = None
D = (1) two-pole switch
T = Single-Pole
L = Left
R = Right
Due to space constraints the disconnect switch and thermostat must always be
mounted on the opposite side of all other controls. Control location and incoming
power connection is determined by the location of the disconnect switch and
thermostat when facing the unit.
For the latest models and information, please visit our website at www.qmarkmep.com79
CONVECTION HEATERS
COMMERCIAL & DECORATIVE PEDESTAL
CPH & DPH SERIES
AVAILABLE COLORS
Navajo Northern Charcoal
White
White
Gray
Neutral
Gray
Custom
Colors
Statuary
Bronze
Desert
Tan
Gloss
Black
Aluminum
IDEAL SPACES | Institutional and Commercial: Offices; Hallways; Lobbies; Condos; Conference Rooms; Retail Spaces;
Terminals; Other Areas Without Wall Mounting Options
COLORS | Neutral Gray; Charcoal Gray; Navajo White; Northern White; Statuary Bronze; Desert Tan; Gloss Black;
Custom Colors Available
DIMENSIONS | See specifications
•
CPH (Commercial) and DPH (Decorative);
ideal for primary, secondary or supplemental
heat where wall mounting is not viable
•
Units can be mounted from wall-to-wall or as discrete
units in standard lengths of 28 in. to 10 ft.
•
Perfect for under-the-window heat loss and
condensation prevention
•
Optional built-in controls include: line voltage
thermostat (SPST or DPST); power on/off switch;
power relay; or transformer relay (see specifications)
•
Durable front cover constructed of 16-gauge steel
(optional 14-gauge available)
•
Right- or left-hand entry/wiring flexibility with identical
pre-wired junction boxes at either end
•
Pedestal-mounted design; bottom inlet - top outlet
•
Built-in wire way with factory-installed wiring rated
35 amps for CPH05 and 45 amps for CPH07
•
Units may contain 1-3 heating elements that yield a
broad range of heating capacity (see specifications)
•
•
Optional 1/4 in. mesh located under the discharge grille
to deter insertion of objects and restriction of airflow
Easy connection of supply wiring from bottom, rear
or end, as well as multiple wiring of adjacent heaters
from one entry point
•
•
Blend into any décor with 8 standard color options or
custom finishes available upon request
For service, all internal parts are accessible by
removing cover
CONTROL COMPARTMENT
(FOR THERMOSTAT & POWER
ON/OFF SWITCH)
NYLON BUSHINGS
HEATING ELEMENT
END CAP
(REQUIRED AT
END OF RUN)
HEATER HOUSING
EXTRUDED ALUMINUM
DISCHARGE GRILLE
PEDESTAL
LEGS
WIREWAY
80
AIR INTAKE
CONTROL COMPARTMENT
(FOR TRANSFORMER & POWER RELAY)
CONVECTION HEATERS
MODELS & SPECIFICATIONS | CPH SERIES (5-1/2” x 3” w/SINGLE ELEMENT)
TOTAL HEATING
CAPACITY
LENGTH
(FT)
CATALOG NO
CPH05A2125
CPH05A2188
CPH05A2250
CPH05A3125
CPH05A3188
CPH05A3250
CPH05A4125
CPH05A4188
CPH05A4250
CPH05A5125
CPH05A5188
CPH05A5250
CPH05A6125
CPH05A6188
CPH05A6250
CPH05A8125
CPH05A8188
CPH05A8250
CPH05A10125
CPH05A10188
CPH05A10250
AMPS
WATTS
PER FT.
TOTAL
WATTS
BTU/HR
120V
208V
240V
277V
347V
600V
125
188
250*
125
188
250*
125
188
250*
125
188
250*
125
188
250*
125
188
250*
125
188
250*
250
375
500
375
546
750
500
750
1000
625
940
1250
750
1125
1500
1000
1500
2000
1250
1875
2500
853
1280
1706
1280
1925
2560
1706
2560
3412
2133
3208
4266
2560
3840
5120
3412
5120
6824
4266
6400
8532
2.1
3.1
4.2
3.1
4.7
6.2
4.2
6.2
8.3
5.2
7.8
10.4
6.2
9.4
12.5
-
1.2
1.8
2.4
1.8
2.7
3.6
2.4
3.6
4.8
3.0
4.5
6.0
3.6
5.4
7.2
4.8
7.2
9.6
6.0
9.0
12.0
1.0
1.6
2.1
1.6
2.4
3.1
2.1
3.1
4.2
2.6
3.9
5.2
3.1
4.7
6.3
4.2
6.3
8.3
5.2
7.8
10.4
0.9
1.4
1.8
1.4
2.0
2.7
1.8
2.7
3.6
2.3
3.4
4.5
2.7
4.1
5.4
3.6
5.4
7.2
4.5
6.8
9.0
0.7
1.1
1.4
1.1
1.6
2.2
1.4
2.2
2.9
1.8
2.7
3.6
2.2
3.2
4.3
2.8
4.3
5.8
3.6
5.4
7.2
0.4
0.6
0.8
0.6
0.9
1.2
0.8
1.2
1.7
1.0
1.6
2.1
1.2
1.9
2.5
1.7
2.5
3.3
2.1
3.1
4.2
2.3
3
4
5
6
8
10
NO. OF
ELEMENTS
SHIP WT.
(LBS)
1
11
1
15
1
18
1
25
1
29
1
38
1
47
MODELS & SPECIFICATIONS | CPH SERIES (7” x 5” w/MULTIPLE ELEMENTS)
TOTAL HEATING
CAPACITY
CATALOG NO
CPH07A2125
CPH07A2188
CPH07A2250
CPH07A2375
CPH07A2500
CPH07A2564
CPH07A2625
CPH07A2750
CPH07A3125
CPH07A3188
CPH07A3250
CPH07A3375
CPH07A3500
CPH07A3564
CPH07A3625
CPH07A3750
CPH07A4125
CPH07A4188
CPH07A4250
CPH07A4375
CPH07A4500
CPH07A4564
CPH07A4625
CPH07A4750
CPH07A5125
CPH07A5188
CPH07A5250
CPH07A5375
CPH07A5500
CPH07A5564
CPH07A5625
CPH07A5750
LENGTH
(FT)
2.3
3
4
5
WATTS
PER FT.
TOTAL
WATTS
BTU/HR
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
250
375
500
750
1000
1125
1250
1500
375
564
750
1125
1500
1690
1875
2250
500
750
1000
1500
2000
2250
2500
3000
624
940
1250
1875
2500
2820
3125
3750
853
1280
1706
2560
3412
3840
4266
5120
1280
1925
2560
3840
5120
5768
6400
7680
1706
2560
3412
5120
6824
7680
8532
10239
2133
3208
4266
6400
8532
9625
10665
12800
CONT. ON NEXT PAGE
AMPS
208V
240V
277V
347V
600V
(1 PH / 3 PH)
(1 PH / 3 PH)
(1 PH)
(1 PH)
(1 PH / 3 PH)
1.2 / 1.8 / 2.4 / 3.6 / 4.8 / 5.4 / 3.1
6.0 / 3.5
7.2 / 4.2
1.8 / 2.7 / 3.6 / 5.4 / 7.2 / 8.1 / 4.7
9.0 / 5.2
10.8 / 6.3
2.4 / 3.6 / 4.8 / 7.2 / 9.6 / 10.8 / 6.3
12.0 / 7.0
14.4 / 8.3
3.0 / 4.5 / 6.0 / 9.0 / 12.0 / 13.6 / 7.8
15.0 / 8.7
18.0 / 10.4
1.0 / 1.6 / 2.1 / 3.1 / 4.2 / 4.7 / 2.7
5.2 / 3.0
6.3 / 3.6
1.6 / 2.4 / 3.1 / 4.7 / 6.3 / 7.0 / 4.1
7.8 / 4.5
9.4 / 5.4
2.1 / 3.1 / 4.2 / 6.3 / 83 / 9.4 / 5.4
10.4 / 6.0
12.5 / 7.2
2.6 / 3.9 / 5.2 / 7.8 / 10.4 / 11.8 / 6.8.
13.0 / 7.5
15.6 / 9.0
0.9
1.4
1.8
2.7
3.6
4.1
4.5
5.4
1.4
2.0
2.7
4.1
5.4
6.1
6.8
8.1
1.8
2.7
3.6
5.4
7.2
8.1
9.0
10.8
2.3
3.4
4.5
6.8
9.0
10.2
11.3
13.5
0.7
1.1
1.4
2.2
2.9
3.2
3.6
4.3
1.1
1.6
2.2
3.2
4.3
4.8
5.4
6.5
1.4
2.2
2.9
4.3
5.8
6.5
7.2
8.6
1.8
2.7
3.6
5.4
7.2
8.1
9.0
10.8
0.4 / 0.6 / 0.8 / 1.2 / 1.7 / 1.9 / 1.1
2.1 / 1.2
2.5 / 1.4
0.6 / 0.9 / 1.2 / 1.9 / 2.5 / 2.8 / 1.6
3.1 / 1.8
3.7 / 2.1
0.8 / 1.2 / 1.7 / 2.5 / 3.3 / 3.7 / 2.1
4.2 / 2.4
5.0 / 2.9
1.0 / 1.6 / 2.1 / 3.1 / 4.2 / 4.7 / 2.7
5.2 / 3.0
6.2 / 3.6
NO. OF
ELEMENTS
SHIP WT.
(LBS)
1
2
18
3
1
2
22
3
1
2
29
3
1
2
37
3
NOTE: All models are NON-STOCK, MADE-TO-ORDER. When ordering, specify quantity, catalog number, voltage, wattage, optional controls, and color. Consult sales representative for lead times.
OPTIONAL CONTROLS ON PAGE 98.
For the latest models and information, please visit our website at www.qmarkmep.com81
CONVECTION HEATERS
MODELS & SPECIFICATIONS | CPH SERIES (7” x 5” w/MULTIPLE ELEMENTS)
TOTAL HEATING
CAPACITY
CATALOG NO
CPH07A6125
CPH07A6188
CPH07A6250
CPH07A6375
CPH07A6500
CPH07A6564
CPH07A6625
CPH07A6750
CPH07A8125
CPH07A8188
CPH07A8250
CPH07A8375
CPH07A8500
CPH07A8564
CPH07A8625
CPH07A8750
CPH07A10125
CPH07A10188
CPH07A10250
CPH07A10375
CPH07A10500
CPH07A10564
CPH07A10625
CPH07A10750
LENGTH
(FT)
6
8
10
WATTS
PER FT.
TOTAL
WATTS
BTU/HR
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
750
1125
1500
2250
3000
3380
3750
4500
1000
1500
2000
3000
4000
4500
5000
6000
1250
1875
2500
3750
5000
5640
6250
7500
2560
3840
5120
7680
10,239
11,535
12,800
15,358
3412
5120
6824
10,239
13,652
15,358
17,065
20,478
4266
6400
8532
12,800
17,065
19,250
21,330
25,600
CONT. FROM PREVIOUS PAGE
AMPS
208V
240V
277V
347V
600V
(1 PH / 3 PH)
(1 PH / 3 PH)
(1 PH)
(1 PH)
(1 PH / 3 PH)
3.6 / 5.4 / 7.2 / 10.8 / 14.4 / 16.3 / 9.4
18.0 / 10.4
21.6 / 12.5
4.8 / 7.2 / 9.6 / 14.4 / 19.2 / 21.6 / 12.5
24.0 / 13.9
28.8 / 16.7
6.0 / 9.0 / 12.0 / 18.0 / 24.0 / 27.1 / 15.7
30.0 / 17.4
36.1 / 20.8
3.1 / 4.7 / 6.3 / 9.4 / 12.5 / 14.1 / 8.1
15.6 / 9.0
18.8 / 10.8
4.2 / 6.3 / 8.3 / 12.5 / 16.7 / 18.8 / 10.8
20.8 / 12.0
25.0 / 14.5
5.2 / 7.8 / 10.4 / 15.6 / 20.8 / 23.5 / 13.6
26.0 / 15.0
31.3 / 18.1
2.7
4.1
5.4
8.1
10.8
12.2
13.5
16.2
3.6
5.4
7.2
10.8
14.4
16.2
18.1
21.7
4.5
6.8
9.0
13.5
18.1
20.4
22.6
27.1
2.2
3.2
4.3
6.5
8.6
9.7
10.8
12.9
2.9
4.3
5.8
8.6
11.5
13.0
14.4
17.3
3.6
5.4
7.2
10.8
14.4
16.2
18.0
21.6
1.2 / 1.9 / 2.5 / 3.7 / 5.0 / 5.6 / 3.2
6.2 / 3.6
7.5 / 4.3
1.7 / 2.5 / 3.3 / 5.0 / 6.7 / 7.5 / 4.3
8.3 / 4.8
10.0 / 5.8
2.1 / 3.1 / 4.2 / 6.2 / 8.3 / 9.4 / 5.4
10.4 / 6.0
12.5 / 7.2
NO. OF
ELEMENTS
SHIP WT.
(LBS)
1
2
44
3
1
2
58
3
1
72
2
3
NOTE: All models are NON-STOCK, MADE-TO-ORDER. When ordering, specify quantity, catalog number, voltage, wattage, optional controls, and color. Consult sales representative for lead times.
OPTIONAL CONTROLS ON PAGE 98.
ACCESSORIES | CPH SERIES
CATALOG NO
DESCRIPTION
CPH05BL21
CPH05BL31
CPH05BL41
CPH05BL51
CPH05BL61
CPH05BL81
CPH05BL101
CPH07BL21
CPH07BL31
CPH07BL41
CPH05BL51
CPH07BL61
CPH07BL81
CPH07BL101
PHB052
PHB053
PHB054
PHB072
PHB073
PHB074
CSH05ECR
CSH07ECR
CSH05ECL
CSH07ECL
28-Inch Blank Section
3-Foot Blank Section
4-Foot Blank Section
5 Foot Blank Section
6-Foot Blank Section
8-Foot Blank Section
10-Foot Blank Section
28-Inch Blank Section
3-Foot Blank Section
4-Foot Blank Section
5 Foot Blank Section
6-Foot Blank Section
8-Foot Blank Section
10-Foot Blank Section
Pedestal Leg Kit for 2, 3 & 4 ft. units
Pedestal Leg Kit for 5, 6 & 8 ft. units
Pedestal Leg Kit for 10 ft. unit
Pedestal Leg Kit for 2, 3 & 4 ft. units
Pedestal Leg Kit for 5, 6 & 8 ft. units
Pedestal Leg Kit for 10 ft. unit
Right Hand End Cap
Right Hand End Cap
Left Hand End Cap
Left Hand End Cap
COMPATIBLE WITH
CPH05A Heaters
CPH05A Heaters
CPH07A Heaters
CPH07A Heaters
Legs must be ordered with
CPH05A Heaters/Blanks
Legs must be ordered with
CPH07A Heaters/Blanks
CPH05A/07A Heaters/Blanks
CPH05A/07A Heaters/Blanks
SHIP WT. (LBS)
10
13
17
21
25
32
42
14
18
24
30
36
48
60
3
4
5
4
5
7
1
1
1
1
NOTE: OPTIONAL CONTROLS ON PAGE 98. Outlet Mesh: Price per foot. 14-Gauge Front Cover: add 10% to heater price. Standard color included in base price. Other colors available. View paint policy on
page 157. If color is not specified, front covers will be neutral grey. Back, grille, and accessories will be statuary bronze. When ordering, specify heater catalog number, voltage, phase, suffix catalog number
for built-in controls, color, and options. Specify color for pedestal legs.
82
CONVECTION HEATERS
MODELS & SPECIFICATIONS | DPH SERIES (5-1/2” x 3” w/SINGLE ELEMENT)
TOTAL HEATING
CAPACITY
LENGTH
(FT)
CATALOG NO
DPH05A2125
DPH05A2188
DPH05A2250
DPH05A3125
DPH05A3188
DPH05A3250
DPH05A4125
DPH05A4188
DPH05A4250
DPH05A5125
DPH05A5188
DPH05A5250
DPH05A6125
DPH05A6188
DPH05A6250
DPH05A8125
DPH05A8188
DPH05A8250
DPH05A10125
DPH05A10188
DPH05A10250
AMPS
WATTS
PER FT.
TOTAL
WATTS
BTU/HR
120V
208V
240V
277V
347V
600V
125
188
250*
125
188
250*
125
188
250*
125
188
250*
125
188
250*
125
188
250*
125
188
250*
250
375
500
375
546
750
500
750
1000
625
940
1250
750
1125
1500
1000
1500
2000
1250
1875
2500
853
1280
1706
1280
1925
2560
1706
2560
3412
2133
3208
4266
2560
3840
5120
3412
5120
6824
4266
6400
8532
2.1
3.1
4.2
3.1
4.7
6.2
4.2
6.2
8.3
5.2
7.8
10.4
6.2
9.4
12.5
-
1.2
1.8
2.4
1.8
2.7
3.6
2.4
3.6
4.8
3.0
4.5
6.0
3.6
5.4
7.2
4.8
7.2
9.6
6.0
9.0
12.0
1.0
1.6
2.1
1.6
2.4
3.1
2.1
3.1
4.2
2.6
3.9
5.2
3.1
4.7
6.3
4.2
6.3
8.3
5.2
7.8
10.4
0.9
1.4
1.8
1.4
2.0
2.7
1.8
2.7
3.6
2.3
3.4
4.5
2.7
4.1
5.4
3.6
5.4
7.2
4.5
6.8
9.0
0.7
1.1
1.4
1.1
1.6
2.2
1.4
2.2
2.9
1.8
2.7
3.6
2.2
3.2
4.3
2.8
4.3
5.8
3.6
5.4
7.2
0.4
0.6
0.8
0.6
0.9
1.2
0.8
1.2
1.7
1.0
1.6
2.1
1.2
1.9
2.5
1.7
2.5
3.3
2.1
3.1
4.2
2.3
3
4
5
6
8
10
NO. OF
ELEMENTS
SHIP WT.
(LBS)
1
11
1
15
1
18
1
25
1
29
1
38
1
47
MODELS & SPECIFICATIONS | DPH SERIES (7” x 5” w/MULTIPLE ELEMENTS)
TOTAL HEATING
CAPACITY
CATALOG NO
DPH07A2125
DPH07A2188
DPH07A2250
DPH07A2375
DPH07A2500
DPH07A2564
DPH07A2625
DPH07A2750
DPH07A3125
DPH07A3188
DPH07A3250
DPH07A3375
DPH07A3500
DPH07A3564
DPH07A3625
DPH07A3750
DPH07A4125
DPH07A4188
DPH07A4250
DPH07A4375
DPH07A4500
DPH07A4564
DPH07A4625
DPH07A4750
DPH07A5125
DPH07A5188
DPH07A5250
DPH07A5375
DPH07A5500
DPH07A5564
DPH07A5625
DPH07A5750
LENGTH
(FT)
2.3
3
4
5
WATTS
PER FT.
TOTAL
WATTS
BTU/HR
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
250
375
500
750
1000
1125
1250
1500
375
564
750
1125
1500
1690
1875
2250
500
750
1000
1500
2000
2250
2500
3000
624
940
1250
1875
2500
2820
3125
3750
853
1280
1706
2560
3412
3840
4266
5120
1280
1925
2560
3840
5120
5768
6400
7680
1706
2560
3412
5120
6824
7680
8532
10239
2133
3208
4266
6400
8532
9625
10665
12800
CONT. ON NEXT PAGE
AMPS
208V
240V
277V
347V
600V
(1 PH / 3 PH)
(1 PH / 3 PH)
(1 PH)
(1 PH)
(1 PH / 3 PH)
1.2 / 1.8 / 2.4 / 3.6 / 4.8 / 5.4 / 3.1
6.0 / 3.5
7.2 / 4.2
1.8 / 2.7 / 3.6 / 5.4 / 7.2 / 8.1 / 4.7
9.0 / 5.2
10.8 / 6.3
2.4 / 3.6 / 4.8 / 7.2 / 9.6 / 10.8 / 6.3
12.0 / 7.0
14.4 / 8.3
3.0 / 4.5 / 6.0 / 9.0 / 12.0 / 13.6 / 7.8
15.0 / 8.7
18.0 / 10.4
1.0 / 1.6 / 2.1 / 3.1 / 4.2 / 4.7 / 2.7
5.2 / 3.0
6.3 / 3.6
1.6 / 2.4 / 3.1 / 4.7 / 6.3 / 7.0 / 4.1
7.8 / 4.5
9.4 / 5.4
2.1 / 3.1 / 4.2 / 6.3 / 83 / 9.4 / 5.4
10.4 / 6.0
12.5 / 7.2
2.6 / 3.9 / 5.2 / 7.8 / 10.4 / 11.8 / 6.8.
13.0 / 7.5
15.6 / 9.0
0.9
1.4
1.8
2.7
3.6
4.1
4.5
5.4
1.4
2.0
2.7
4.1
5.4
6.1
6.8
8.1
1.8
2.7
3.6
5.4
7.2
8.1
9.0
10.8
2.3
3.4
4.5
6.8
9.0
10.2
11.3
13.5
0.7
1.1
1.4
2.2
2.9
3.2
3.6
4.3
1.1
1.6
2.2
3.2
4.3
4.8
5.4
6.5
1.4
2.2
2.9
4.3
5.8
6.5
7.2
8.6
1.8
2.7
3.6
5.4
7.2
8.1
9.0
10.8
0.4 / 0.6 / 0.8 / 1.2 / 1.7 / 1.9 / 1.1
2.1 / 1.2
2.5 / 1.4
0.6 / 0.9 / 1.2 / 1.9 / 2.5 / 2.8 / 1.6
3.1 / 1.8
3.7 / 2.1
0.8 / 1.2 / 1.7 / 2.5 / 3.3 / 3.7 / 2.1
4.2 / 2.4
5.0 / 2.9
1.0 / 1.6 / 2.1 / 3.1 / 4.2 / 4.7 / 2.7
5.2 / 3.0
6.2 / 3.6
NO. OF
ELEMENTS
SHIP WT.
(LBS)
1
2
18
3
1
2
22
3
1
2
29
3
1
2
37
3
NOTE: All models are NON-STOCK, MADE-TO-ORDER. When ordering, specify quantity, catalog number, voltage, wattage, optional controls, and color. Consult sales representative for lead times.
OPTIONAL CONTROLS ON PAGE 98.
For the latest models and information, please visit our website at www.qmarkmep.com83
CONVECTION HEATERS
MODELS & SPECIFICATIONS | DPH SERIES (7” x 5” w/MULTIPLE ELEMENTS)
TOTAL HEATING
CAPACITY
CATALOG NO
DPH07A6125
DPH07A6188
DPH07A6250
DPH07A6375
DPH07A6500
DPH07A6564
DPH07A6625
DPH07A6750
DPH07A8125
DPH07A8188
DPH07A8250
DPH07A8375
DPH07A8500
DPH07A8564
DPH07A8625
DPH07A8750
DPH07A10125
DPH07A10188
DPH07A10250
DPH07A10375
DPH07A10500
DPH07A10564
DPH07A10625
DPH07A10750
LENGTH
(FT)
6
8
10
WATTS
PER FT.
TOTAL
WATTS
BTU/HR
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
750
1125
1500
2250
3000
3380
3750
4500
1000
1500
2000
3000
4000
4500
5000
6000
1250
1875
2500
3750
5000
5640
6250
7500
2560
3840
5120
7680
10,239
11,535
12,800
15,358
3412
5120
6824
10,239
13,652
15,358
17,065
20,478
4266
6400
8532
12,800
17,065
19,250
21,330
25,600
CONT. FROM PREVIOUS PAGE
AMPS
208V
240V
277V
347V
600V
(1 PH / 3 PH)
(1 PH / 3 PH)
(1 PH)
(1 PH)
(1 PH / 3 PH)
3.6 / 5.4 / 7.2 / 10.8 / 14.4 / 16.3 / 9.4
18.0 / 10.4
21.6 / 12.5
4.8 / 7.2 / 9.6 / 14.4 / 19.2 / 21.6 / 12.5
24.0 / 13.9
28.8 / 16.7
6.0 / 9.0 / 12.0 / 18.0 / 24.0 / 27.1 / 15.7
30.0 / 17.4
36.1 / 20.8
3.1 / 4.7 / 6.3 / 9.4 / 12.5 / 14.1 / 8.1
15.6 / 9.0
18.8 / 10.8
4.2 / 6.3 / 8.3 / 12.5 / 16.7 / 18.8 / 10.8
20.8 / 12.0
25.0 / 14.5
5.2 / 7.8 / 10.4 / 15.6 / 20.8 / 23.5 / 13.6
26.0 / 15.0
31.3 / 18.1
2.7
4.1
5.4
8.1
10.8
12.2
13.5
16.2
3.6
5.4
7.2
10.8
14.4
16.2
18.1
21.7
4.5
6.8
9.0
13.5
18.1
20.4
22.6
27.1
2.2
3.2
4.3
6.5
8.6
9.7
10.8
12.9
2.9
4.3
5.8
8.6
11.5
13.0
14.4
17.3
3.6
5.4
7.2
10.8
14.4
16.2
18.0
21.6
1.2 / 1.9 / 2.5 / 3.7 / 5.0 / 5.6 / 3.2
6.2 / 3.6
7.5 / 4.3
1.7 / 2.5 / 3.3 / 5.0 / 6.7 / 7.5 / 4.3
8.3 / 4.8
10.0 / 5.8
2.1 / 3.1 / 4.2 / 6.2 / 8.3 / 9.4 / 5.4
10.4 / 6.0
12.5 / 7.2
NO. OF
ELEMENTS
SHIP WT.
(LBS)
1
2
44
3
1
2
58
3
1
72
2
3
NOTE: All models are NON-STOCK, MADE-TO-ORDER. When ordering, specify quantity, catalog number, voltage, wattage, optional controls, and color. Consult sales representative for lead times.
OPTIONAL CONTROLS ON PAGE 98.
ACCESSORIES | DPH SERIES
CATALOG NO
DESCRIPTION
DPH05BL21
DPH05BL31
DPH05BL41
DPH05BL51
DPH05BL61
DPH05BL81
DPH05BL101
DPH07BL21
DPH07BL31
DPH07BL41
DPH05BL51
DPH07BL61
DPH07BL81
DPH07BL101
PHB052
PHB053
PHB054
PHB072
PHB073
PHB074
DSH05ECR
DSH07ECR
DSH05ECL
DSH07ECL
28-Inch Blank Section
3-Foot Blank Section
4-Foot Blank Section
5 Foot Blank Section
6-Foot Blank Section
8-Foot Blank Section
10-Foot Blank Section
28-Inch Blank Section
3-Foot Blank Section
4-Foot Blank Section
5 Foot Blank Section
6-Foot Blank Section
8-Foot Blank Section
10-Foot Blank Section
Pedestal Leg Kit for 2, 3 & 4 ft. units
Pedestal Leg Kit for 5, 6 & 8 ft. units
Pedestal Leg Kit for 10 ft. unit
Pedestal Leg Kit for 2, 3 & 4 ft. units
Pedestal Leg Kit for 5, 6 & 8 ft. units
Pedestal Leg Kit for 10 ft. unit
Right Hand End Cap
Right Hand End Cap
Left Hand End Cap
Left Hand End Cap
COMPATIBLE WITH
DPH05A Heaters
DPH05A Heaters
DPH07A Heaters
DPH07A Heaters
Legs must be ordered with
DPH05A Heaters/Blanks
Legs must be ordered with
DPH07A Heaters/Blanks
DPH05A/07A Heaters/Blanks
DPH05A/07A Heaters/Blanks
SHIP WT. (LBS)
10
13
17
21
25
32
42
14
18
24
30
36
48
60
3
4
5
4
5
7
1
1
1
1
NOTE: OPTIONAL CONTROLS ON PAGE 98. Outlet Mesh: Price per foot. 14-Gauge Front Cover: add 10% to heater price. Standard color included in base price. Other colors available. View paint policy on
page 157. If color is not specified, front covers will be neutral grey. Back, grille, and accessories will be statuary bronze. When ordering, specify heater catalog number, voltage, phase, suffix catalog number
for built-in controls, color, and options. Specify color for pedestal legs.
84
CONVECTION HEATERS
ACCESSORIES | CPH & DPH SERIES
CATALOG NO
COMPATIBLE
WITH
HEIGHT
(IN)
LENGTH
(IN)
DEPTH
(IN)
ADDT’L
LENGTH* (IN)
LEFT END CAPS
CSH05ECL**
CPH05
5-1/2
2-1/2
CSH07ECL**
CPH07
7
4-3/4
DSH05ECL**
DPH05
5-1/2
2-1/2
DSH07ECL**
DPH07
7
4-3/4
RIGHT END CAPS
CSH05ECR**
CPH05
5-1/2
2-1/2
CSH07ECR**
CPH07
7
4-3/4
DSH05ECR**
DPH05
5-1/2
2-1/2
DSH07ECR**
DPH07
7
4-3/4
PEDESTAL LEGS (FOR CPH05 AND DPH05 HEATERS)
PHB052**
2, 3, & 4 ft. heaters and blank sections
PHB053**
5, 6, & 8 ft. heaters and blank sections
10 ft. heaters and blank sections
PHB054**
1/8
1/8
PEDESTAL LEGS (FOR CPH07 AND DPH07 HEATERS)
PHB072**
PHB073**
PHB074**
BLANK SECTIONS (CPH05)
CPH05BL21
CPH05BL31
CPH05BL41
CPH05BL51
CPH05
CPH05BL61
CPH05BL81
CPH05BL101
BLANK SECTIONS (CPH07)
CPH07BL21
CPH07BL31
CPH07BL41
CPH07
CPH07BL51
CPH07BL61
CPH07BL81
CPH07BL101
BLANK SECTIONS (DPH05)
DPH05BL21
DPH05BL31
DPH05BL41
DPH05BL51
DPH05
DPH05BL61
DPH05BL81
DPH05BL101
BLANK SECTIONS (DPH07)
DPH07BL21
DPH07BL31
DPH07BL41
DPH07BL51
DPH07
DPH07BL61
DPH07BL81
DPH07BL101
2, 3, & 4 ft. heaters and blank sections
5, 6, & 8 ft. heaters and blank sections
10 ft. heaters and blank sections
5-1/2
7
5-1/2
7
3
28
36
48
60
72
96
120
28
36
48
60
72
96
120
5
28
36
48
60
72
96
120
28
36
48
60
72
96
120
3
28
36
48
60
72
96
120
28
36
48
60
72
96
120
5
28
36
48
60
72
96
120
28
36
48
60
72
96
120
NOTE: *Additional length the accessory adds to the total installation. * *Built-in duplex receptacle available.
(See diagram to right.)
MOUNTING | CPH & DPH SERIES
HEATER CAPACITY
(Watt/Ft.)
125, 188 and 250
375, 500, 564, 625 and 750
HEATER DIMENSION “A” (IN.)
(Minimum Mounting Height Above Floor)
PEDESTAL DIMENSION “B” (IN.)
(Minimum Height Above Floor)
1-3/4
2
3
3-1/4
CATALOG NO.
HEIGHT ABOVE
FLOOR (IN.)
MIN.
MAX.
DPH05
2-5/8
3-3/8
DPH07
3-7/8
4-5/8
For the latest models and information, please visit our website at www.qmarkmep.com85
CONVECTION HEATERS
COMMERCIAL SILL-HEIGHT CONVECTOR
CSH SERIES
AVAILABLE COLORS
Navajo Northern Charcoal
White
White
Gray
Neutral
Gray
Custom
Colors
Statuary
Bronze
Desert
Tan
Gloss
Black
Aluminum
IDEAL SPACES | Offices; Hallways; Lobbies; Conference Rooms; Retail; Other Similar Areas with Floor-to-Ceiling Windows
COLORS | Neutral Gray; Charcoal Gray; Navajo White; Northern White; Statuary Bronze; Desert Tan; Black;
Custom Colors, Baked Enamel Finishes Available
DIMENSIONS | See specifications
•
Perfect for under-the-window heat loss and
condensation prevention
•
Units can be mounted from wall-to-wall or as discrete
units in standard lengths of 28 in. to 10 ft.
•
Durable front cover constructed of 16-gauge steel
(optional 14-gauge available)
•
•
Wall-mounted design; bottom or front inlet - top outlet
Optional built-in controls include: line voltage
thermostat (SPST or DPST); two-stage thermostat;
power on/off switch; transformer relay; and power
relay (see specifications)
•
Units may contain 1-3 heating elements that yield a
broad range of heating capacity (see specifications)
•
•
Optional 1/4 in. mesh located under the discharge grille
to deter insertion of objects and restriction of airflow
Right- or left-hand entry/wiring flexibility with identical
pre-wired junction boxes at either end
•
•
Blend into any décor with 8 standard color options or
custom finishes and anodizing available upon request
Easy connection of supply wiring from bottom, rear
or end, as well as multiple wiring of adjacent heaters
from one entry point
•
Locate at sill height (or lower) or run from mullion-to-mullion
•
For service, all internal parts are accessible by
removing cover
Front inlet models mount flush with floor; 125 to 250 watts per foot units can be positioned within 1-3/4 in. of floor; 375 to 750 watts per foot units can be positioned to within 3 in. of
floor; 5-1/2 in. and 7 in. high models are available with top outlet only; 14 in. models are available with top or front outlet.
86
CONVECTION HEATERS
MODELS & SPECIFICATIONS | CSH05 (5-1/2” x 3” w/SINGLE ELEMENT)
TOTAL HEATING
CAPACITY
LENGTH
(FT)
CATALOG NO
CSH05A2125
CSH05A2188
CSH05A2250
CSH05A3125
CSH05A3188
CSH05A3250
CSH05A4125
CSH05A4188
CSH05A4250
CSH05A5125
CSH05A5188
CSH05A5250
CSH05A6125
CSH05A6188
CSH05A6250
CSH05A8125
CSH05A8188
CSH05A8250
CSH05A10125
CSH05A10188
CSH05A10250
AMPS
WATTS
PER FT.
TOTAL
WATTS
BTU/HR
120V
208V
240V
277V
347V
600V
125
188
250
125
188
250
125
188
250
125
188
250
125
188
250
125
188
250
125
188
250
250
375
500
375
546
750
500
750
1000
625
940
1250
750
1125
1500
1000
1500
2000
1250
1875
2500
853
1280
1706
1280
1925
2560
1706
2560
3412
2133
3208
4266
2560
3840
5120
3412
5120
6824
4266
6400
8532
2.1
3.1
4.2
3.1
4.7
6.2
4.2
6.2
8.3
5.2
7.8
10.4
6.2
9.4
12.5
-
1.2
1.8
2.4
1.8
2.7
3.6
2.4
3.6
4.8
3.0
4.5
6.0
3.6
5.4
7.2
4.8
7.2
9.6
6.0
9.0
12.0
1.0
1.6
2.1
1.6
2.4
3.1
2.1
3.1
4.2
2.6
3.9
5.2
3.1
4.7
6.3
4.2
6.3
8.3
5.2
7.8
10.4
0.9
1.4
1.8
1.4
2.0
2.7
1.8
2.7
3.6
2.3
3.4
4.5
2.7
4.1
5.4
3.6
5.4
7.2
4.5
6.8
9.0
0.7
1.1
1.4
1.1
1.6
2.2
1.4
2.2
2.9
1.8
2.7
3.6
2.2
3.2
4.3
2.8
4.3
5.8
3.6
5.4
7.2
0.4
0.6
0.8
0.6
0.9
1.2
0.8
1.2
1.7
1.0
1.6
2.1
1.2
1.9
2.5
1.7
2.5
3.3
2.1
3.1
4.2
2.3
3
4
5
6
8
10
NO. OF
ELEMENTS
SHIP WT.
(LBS)
1
11
1
14
1
19
1
23
1
27
1
37
1
47
MODELS & SPECIFICATIONS | CSH07 (7” x 5” w/MULTIPLE ELEMENTS)
TOTAL HEATING
CAPACITY
CATALOG NO
CSH07A2125
CSH07A2188
CSH07A2250
CSH07A2375
CSH07A2500
CSH07A2564
CSH07A2625
CSH07A2750
CSH07A3125
CSH07A3188
CSH07A3250
CSH07A3375
CSH07A3500
CSH07A3564
CSH07A3625
CSH07A-3750
CSH07A4125
CSH07A4188
CSH07A4250
CSH07A4375
CSH07A4500
CSH07A4564
CSH07A4625
CSH07A4750
CSH07A5125
CSH07A5188
CSH07A5250
CSH07A5375
CSH07A5500
CSH07A5564
CSH07A5625
CSH07A5750
LENGTH
(FT)
2.3
3
4
5
WATTS
PER FT.
TOTAL
WATTS
BTU/HR
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
250
375
500
750
1000
1125
1250
1500
375
564
750
1125
1500
1690
1875
2250
500
750
1000
1500
2000
2250
2500
3000
624
940
1250
1875
2500
2820
3125
3750
853
1280
1706
2560
3412
3840
4266
5120
1280
1925
2560
3840
5120
5768
6400
7680
1706
2560
3412
5120
6824
7680
8532
10239
2133
3208
4266
6400
8532
9625
10665
12800
CONT. ON NEXT PAGE
AMPS
208V
240V
277V
347V
600V
(1 PH / 3 PH)
(1 PH / 3 PH)
(1 PH)
(1 PH)
(1 PH / 3 PH)
1.2 / 1.8 / 2.4 / 3.6 / 4.8 / 5.4 / 3.1
6.0 / 3.5
7.2 / 4.2
1.8 / 2.7 / 3.6 / 5.4 / 7.2 / 8.1 / 4.7
9.0 / 5.2
10.8 / 6.3
2.4 / 3.6 / 4.8 / 7.2 / 9.6 / 10.8 / 6.3
12.0 / 7.0
14.4 / 8.3
3.0 / 4.5 / 6.0 / 9.0 / 12.0 / 13.6 / 7.8
15.0 / 8.7
18.0 / 10.4
1.0 / 1.6 / 2.1 / 3.1 / 4.2 / 4.7 / 2.7
5.2 / 3.0
6.3 / 3.6
1.6 / 2.4 / 3.1 / 4.7 / 6.3 / 7.0 / 4.1
7.8 / 4.5
9.4 / 5.4
2.1 / 3.1 / 4.2 / 6.3 / 83 / 9.4 / 5.4
10.4 / 6.0
12.5 / 7.2
2.6 / 3.9 / 5.2 / 7.8 / 10.4 / 11.8 / 6.8.
13.0 / 7.5
15.6 / 9.0
0.9
1.4
1.8
2.7
3.6
4.1
4.5
5.4
1.4
2.0
2.7
4.1
5.4
6.1
6.8
8.1
1.8
2.7
3.6
5.4
7.2
8.1
9.0
10.8
2.3
3.4
4.5
6.8
9.0
10.2
11.3
13.5
0.7
1.1
1.4
2.2
2.9
3.2
3.6
4.3
1.1
1.6
2.2
3.2
4.3
4.8
5.4
6.5
1.4
2.2
2.9
4.3
5.8
6.5
7.2
8.6
1.8
2.7
3.6
5.4
7.2
8.1
9.0
10.8
0.4 / 0.6 / 0.8 / 1.2 / 1.7 / 1.9 / 1.1
2.1 / 1.2
2.5 / 1.4
0.6 / 0.9 / 1.2 / 1.9 / 2.5 / 2.8 / 1.6
3.1 / 1.8
3.7 / 2.1
0.8 / 1.2 / 1.7 / 2.5 / 3.3 / 3.7 / 2.1
4.2 / 2.4
5.0 / 2.9
1.0 / 1.6 / 2.1 / 3.1 / 4.2 / 4.7 / 2.7
5.2 / 3.0
6.2 / 3.6
NO. OF
ELEMENTS
SHIP WT.
(LBS)
1
2
17
3
1
2
21
3
1
2
28
3
1
2
35
3
NOTE: All models are NON-STOCK, MADE-TO-ORDER. When ordering, specify quantity, catalog number, voltage, wattage, optional controls, and color. Consult sales representative for lead times.
OPTIONAL CONTROLS ON PAGE 98.
For the latest models and information, please visit our website at www.qmarkmep.com87
CONVECTION HEATERS
MODELS & SPECIFICATIONS | CSH07 (7” x 5” w/MULTIPLE ELEMENTS)
TOTAL HEATING
CAPACITY
CATALOG NO
CSH07A6125
CSH07A6188
CSH07A6250
CSH07A6375
CSH07A6500
CSH07A6564
CSH07A6625
CSH07A6750
CSH07A8125
CSH07A8188
CSH07A8250
CSH07A8375
CSH07A8500
CSH07A8564
CSH07A8625
CSH07A8750
CSH07A10125
CSH07A10188
CSH07A10250
CSH07A10375
CSH07A10500
CSH07A10564
CSH07A10625
CSH07A10750
LENGTH
(FT)
6
8
10
WATTS
PER FT.
TOTAL
WATTS
BTU/HR
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
750
1125
1500
2250
3000
3380
3750
4500
1000
1500
2000
3000
4000
4500
5000
6000
1250
1875
2500
3750
5000
5640
6250
7500
2560
3840
5120
7680
10,239
11,535
12,800
15,358
3412
5120
6824
10,239
13,652
15,358
17,065
20,478
4266
6400
8532
12,800
17,065
19,250
21,330
25,600
CONT. FROM PREVIOUS PAGE
AMPS
208V
240V
277V
347V
600V
(1 PH / 3 PH)
(1 PH / 3 PH)
(1 PH)
(1 PH)
(1 PH / 3 PH)
3.6 / 5.4 / 7.2 / 10.8 / 14.4 / 16.3 / 9.4
18.0 / 10.4
21.6 / 12.5
4.8 / 7.2 / 9.6 / 14.4 / 19.2 / 21.6 / 12.5
24.0 / 13.9
28.8 / 16.7
6.0 / 9.0 / 12.0 / 18.0 / 24.0 / 27.1 / 15.7
30.0 / 17.4
36.1 / 20.8
3.1 / 4.7 / 6.3 / 9.4 / 12.5 / 14.1 / 8.1
15.6 / 9.0
18.8 / 10.8
4.2 / 6.3 / 8.3 / 12.5 / 16.7 / 18.8 / 10.8
20.8 / 12.0
25.0 / 14.5
5.2 / 7.8 / 10.4 / 15.6 / 20.8 / 23.5 / 13.6
26.0 / 15.0
31.3 / 18.1
2.7
4.1
5.4
8.1
10.8
12.2
13.5
16.2
3.6
5.4
7.2
10.8
14.4
16.2
18.1
21.7
4.5
6.8
9.0
13.5
18.1
20.4
22.6
27.1
2.2
3.2
4.3
6.5
8.6
9.7
10.8
12.9
2.9
4.3
5.8
8.6
11.5
13.0
14.4
17.3
3.6
5.4
7.2
10.8
14.4
16.2
18.0
21.6
1.2 / 1.9 / 2.5 / 3.7 / 5.0 / 5.6 / 3.2
6.2 / 3.6
7.5 / 4.3
1.7 / 2.5 / 3.3 / 5.0 / 6.7 / 7.5 / 4.3
8.3 / 4.8
10.0 / 5.8
2.1 / 3.1 / 4.2 / 6.2 / 8.3 / 9.4 / 5.4
10.4 / 6.0
12.5 / 7.2
NO. OF
ELEMENTS
1
2
CATALOG NO
CSH14A2125
CSH14A2188
CSH14A2250
CSH14A2375
CSH14A2500
CSH14A2564
CSH14A2625
CSH14A2750
CSH14A3125
CSH14A3188
CSH14A3250
CSH14A3375
CSH14A3500
CSH14A3564
CSH14A3625
CSH14A-3750
CSH14A4125
CSH14A4188
CSH14A4250
CSH14A4375
CSH14A4500
CSH14A4564
CSH14A4625
CSH14A4750
LENGTH
(FT)
2.3
3
4
WATTS
PER FT.
TOTAL
WATTS
BTU/HR
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
250
375
500
750
1000
1125
1250
1500
375
564
750
1125
1500
1690
1875
2250
500
750
1000
1500
2000
2250
2500
3000
853
1280
1706
2560
3412
3840
4266
5120
1280
1925
2560
3840
5120
5768
6400
7680
1706
2560
3412
5120
6824
7680
8532
10239
42
3
1
2
56
3
1
70
2
3
MODELS & SPECIFICATIONS | CSH14 (14” x 5” w/MULTIPLE ELEMENTS)
TOTAL HEATING
CAPACITY
SHIP WT.
(LBS)
CONT. ON NEXT PAGE
AMPS
208V
240V
277V
347V
600V
(1 PH / 3 PH)
(1 PH / 3 PH)
(1 PH)
(1 PH)
(1 PH / 3 PH)
1.2 / 1.8 / 2.4 / 3.6 / 4.8 / 5.4 / 3.1
6.0 / 3.5
7.2 / 4.2
1.8 / 2.7 / 3.6 / 5.4 / 7.2 / 8.1 / 4.7
9.0 / 5.2
10.8 / 6.3
2.4 / 3.6 / 4.8 / 7.2 / 9.6 / 10.8 / 6.3
12.0 / 7.0
14.4 / 8.3
1.0 / 1.6 / 2.1 / 3.1 / 4.2 / 4.7 / 2.7
5.2 / 3.0
6.3 / 3.6
1.6 / 2.4 / 3.1 / 4.7 / 6.3 / 7.0 / 4.1
7.8 / 4.5
9.4 / 5.4
2.1 / 3.1 / 4.2 / 6.3 / 83 / 9.4 / 5.4
10.4 / 6.0
12.5 / 7.2
0.9
1.4
1.8
2.7
3.6
4.1
4.5
5.4
1.4
2.0
2.7
4.1
5.4
6.1
6.8
8.1
1.8
2.7
3.6
5.4
7.2
8.1
9.0
10.8
0.7
1.1
1.4
2.2
2.9
3.2
3.6
4.3
1.1
1.6
2.2
3.2
4.3
4.8
5.4
6.5
1.4
2.2
2.9
4.3
5.8
6.5
7.2
8.6
0.4 / 0.6 / 0.8 / 1.2 / 1.7 / 1.9 / 1.1
2.1 / 1.2
2.5 / 1.4
0.6 / 0.9 / 1.2 / 1.9 / 2.5 / 2.8 / 1.6
3.1 / 1.8
3.7 / 2.1
0.8 / 1.2 / 1.7 / 2.5 / 3.3 / 3.7 / 2.1
4.2 / 2.4
5.0 / 2.9
NO. OF
ELEMENTS
SHIP WT.
(LBS)
1
2
25
3
1
2
32
3
1
2
42
3
NOTE: All models are NON-STOCK, MADE-TO-ORDER. When ordering, specify quantity, catalog number, voltage, wattage, optional controls, and color. Consult sales representative for lead times.
OPTIONAL CONTROLS ON PAGE 98.
88
CONVECTION HEATERS
MODELS & SPECIFICATIONS | CSH14 (14” x 5” w/MULTIPLE ELEMENTS)
CATALOG NO
CSH14A5125
CSH14A5188
CSH14A5250
CSH14A5375
CSH14A5500
CSH14A5564
CSH14A5625
CSH14A5750
CSH14A6125
CSH14A6188
CSH14A6250
CSH14A6375
CSH14A6500
CSH14A6564
CSH14A6625
CSH14A6750
CSH14A8125
CSH14A8188
CSH14A8250
CSH14A8375
CSH14A8500
CSH14A8564
CSH14A8625
CSH14A8750
CSH14A10125
CSH14A10188
CSH14A10250
CSH14A10375
CSH14A10500
CSH14A10564
CSH14A10625
CSH14A10750
LENGTH
(FT)
5
6
8
10
WATTS
PER FT.
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
TOTAL HEATING
CAPACITY
TOTAL
BTU/HR
WATTS
624
2133
940
3208
1250
4266
1875
6400
2500
8532
2820
9625
3125
10665
3750
12800
750
2560
1125
3840
1500
5120
2250
7680
3000
10,239
3380
11,535
3750
12,800
4500
15,358
1000
3412
1500
5120
2000
6824
3000
10,239
4000
13,652
4500
15,358
5000
17,065
6000
20,478
1250
4266
1875
6400
2500
8532
3750
12,800
5000
17,065
5640
19,250
6250
21,330
7500
25,600
AMPS
208V
(1 PH / 3 PH)
3.0 / 4.5 / 6.0 / 9.0 / 12.0 / 13.6 / 7.8
15.0 / 8.7
18.0 / 10.4
3.6 / 5.4 / 7.2 / 10.8 / 14.4 / 16.3 / 9.4
18.0 / 10.4
21.6 / 12.5
4.8 / 7.2 / 9.6 / 14.4 / 19.2 / 21.6 / 12.5
24.0 / 13.9
28.8 / 16.7
6.0 / 9.0 / 12.0 / 18.0 / 24.0 / 27.1 / 15.7
30.0 / 17.4
36.1 / 20.8
ACCESSORIES | CPH SERIES
CATALOG NO.
DESCRIPTION
CSH05BL21*
CSH05BL31*
CSH05BL41*
CSH05BL51*
CSH05BL61*
CSH05BL81*
CSH05BL101*
CSH07BL21*
CSH07BL31*
CSH07BL41*
CSH07BL51*
CSH07BL61*
CSH07BL81*
CSH07BL101*
CSH14BL21*
CSH14BL31*
CSH14BL41*
CSH14BL51*
CSH14BL61*
CSH14BL81*
CSH14BL101*
Stand-Off
Bracket
28 in. Blank Section
3 ft. Blank Section
4 ft. Blank Section
5 ft. Blank Section
6 ft. Blank Section
8 ft. Blank Section
10 ft. Blank Section
28 in. Blank Section
3 ft. Blank Section
4 ft. Blank Section
5 ft. Blank Section
6 ft. Blank Section
8 ft. Blank Section
10 ft. Blank Section
28 in. Blank Section
3 ft. Blank Section
4 ft. Blank Section
5 ft. Blank Section
6 ft. Blank Section
8 ft. Blank Section
10 ft. Blank Section
SO1
SO2
COMPATIBLE WITH
CSH05 Heaters
CSH07 Heaters
CSH14 Heaters
CSH05 Heaters
CSH07 Heaters
CONT. FROM PREVIOUS PAGE
SHIP WT. (LBS)
10
14
18
23
27
36
45
16
20
26
33
39
52
65
23
30
40
50
60
80
100
1
1
NOTE: OPTIONAL CONTROLS ON PAGE 98. Outlet Mesh: Price per foot. 14-Gauge Front Cover:
add 10% to heater price. Standard color included in base price. Other colors available. View paint
policy on page 157. Maximum of 250 watts per ft. on front outlet models. When ordering, specify heater
catalog number, voltage, phase, suffix catalog number for built-in controls, color, and options. 2. If color
is not specified, front covers will be neutral grey. Front outlet models available only in 14 in. height and
125, 188 and 250 Wt./Ft. configuration. Outlet mesh is not available on front outlet models.
240V
(1 PH / 3 PH)
2.6 / 3.9 / 5.2 / 7.8 / 10.4 / 11.8 / 6.8.
13.0 / 7.5
15.6 / 9.0
3.1 / 4.7 / 6.3 / 9.4 / 12.5 / 14.1 / 8.1
15.6 / 9.0
18.8 / 10.8
4.2 / 6.3 / 8.3 / 12.5 / 16.7 / 18.8 / 10.8
20.8 / 12.0
25.0 / 14.5
5.2 / 7.8 / 10.4 / 15.6 / 20.8 / 23.5 / 13.6
26.0 / 15.0
31.3 / 18.1
277V
(1 PH)
2.3
3.4
4.5
6.8
9.0
10.2
11.3
13.5
2.7
4.1
5.4
8.1
10.8
12.2
13.5
16.2
3.6
5.4
7.2
10.8
14.4
16.2
18.1
21.7
4.5
6.8
9.0
13.5
18.1
20.4
22.6
27.1
CATALOG NO.
CSH05ECL
CSH07ECL
CSH14ECL
CSH05ECR
CSH07ECR
CSH14ECR
CSH05FL3
CSH07FL3
CSH14FL3
CSH05FL6
CSH07FL6
CSH14FL6
CSH05FL9
CSH07FL9
CSH14FL9
CSH05F12
CSH07FL12
CSH14FL12
CSH05FL18
CSH07FL18
CSH14FL18
CSH05IC1*
CSH07IC1*
CSH14IC1*
CSH05OC1*
CSH07OC1*
CSH14OC1*
SHCC05
SHCC0714
347V
(1 PH)
1.8
2.7
3.6
5.4
7.2
8.1
9.0
10.8
2.2
3.2
4.3
6.5
8.6
9.7
10.8
12.9
2.9
4.3
5.8
8.6
11.5
13.0
14.4
17.3
3.6
5.4
7.2
10.8
14.4
16.2
18.0
21.6
600V
(1 PH / 3 PH)
1.0 / 1.6 / 2.1 / 3.1 / 4.2 / 4.7 / 2.7
5.2 / 3.0
6.2 / 3.6
1.2 / 1.9 / 2.5 / 3.7 / 5.0 / 5.6 / 3.2
6.2 / 3.6
7.5 / 4.3
1.7 / 2.5 / 3.3 / 5.0 / 6.7 / 7.5 / 4.3
8.3 / 4.8
10.0 / 5.8
2.1 / 3.1 / 4.2 / 6.2 / 8.3 / 9.4 / 5.4
10.4 / 6.0
12.5 / 7.2
NO. OF
ELEMENTS
SHIP WT.
(LBS)
1
2
53
3
1
2
60
3
1
2
80
3
1
2
100
3
DESCRIPTION
COMPATIBLE WITH
Left End Caps
All CSH Heaters
Right End Caps
All CSH Heaters
3 in. Filler Section
All CSH Heaters
6 in. Filler Section
All CSH Heaters
9 in. Filler Section
All CSH Heaters
12 in. Filler Section
All CSH Heaters
18 in. Filler Section
All CSH Heaters
Inside Corners
All CSH Heaters
Outside Corners
All CSH Heaters
Conduit Corners
All CSH Heaters
SHIP WT. (LBS)
1
1
1
1
1
1
1
2
3
2
3
5
3
4
6
4
5
8
5
6
9
2
4
6
1
2
4
4
5
For the latest models and information, please visit our website at www.qmarkmep.com89
CONVECTION HEATERS
ACCESSORIES
CATALOG NO
COMPATIBLE
WITH
HEIGHT
(IN)
DEPTH
(IN)
LENGTH
(IN)
ADDT’L
LENGTH* (IN)
CSH05
CSH07
CSH14
5-1/2
7
14
2-1/2
4-1/4
4-1/4
-
1/8
CSH05
CSH07
CSH14
5-1/2
7
14
2-1/2
4-1/4
4-1/4
-
1/8
CSH05
CSH07
CSH14
CSH05
CSH07
CSH14
CSH05
CSH07
CSH14
CSH05
CSH07
CSH14
CSH05
CSH07
CSH14
5-1/2
7
14
5-1/8
6-1/8
13-1/8
5-1/8
6-1/8
13-1/8
5-1/8
6-1/8
13-1/8
5-1/8
6-1/8
13-1/8
5-1/8
6-1/8
13-1/8
2-1/2
4-1/2
4-1/2
2-1/2
4-1/2
4-1/2
2-1/2
4-1/2
4-1/2
2-1/2
4-1/2
4-1/2
4
0-3
7
3-6
10
6-9
13
9-12
19
15-18
CSH05
CSH07
CSH14
5-1/8
6-1/8
13-1/8
2-1/2
4-1/2
4-1/2
4-1/2
6
6
3-3-1/2
5-5-1/2
5-5-1/2
CSH05
CSH07
CSH14
5-1/8
6-1/8
13-1/8
2-1/2
4-1/2
4-1/2
1
0-1/2
CSH05
CSH07
CSH14
-
2-5/8
3-5/8
2-1/2
3
-
4-3/4
6-3/4
3/4
3/4
3
3
-
3
28
36
48
60
72
96
120
28
36
48
60
72
96
120
5
28
36
48
60
72
96
120
28
36
48
60
72
96
120
5
28
36
48
60
72
96
120
28
36
48
60
72
96
120
LEFT END CAPS
CSH05ECL**
CSH07ECL**
CSH14ECL**
RIGHT END CAPS
CSH05ECR**
CSH07ECR**
CSH14ECR**
FILLER SECTIONS
CSH05FL3
CSH07FL3
CSH14FL3
CSH05FL6**
CSH07FL6**
CSH14FL6**
CSH05FL9**
CSH07FL9**
CSH14FL9**
CSH05FL12**
CSH07FL12**
CSH14FL12**
CSH05FL18**
CSH07FL18**
CSH14FL18**
INSIDE CORNERS
CSH05IC1
CSH07IC1
CSH14IC1
OUTSIDE CORNERS
CSH05OC1
CSH07OC1
CSH14OC1
CONDUIT CORNERS
SHCC05
SHCC07
SHCC14
STAND-OFF BRACKETS
SO1
CSH05
SO2
CSH07
BLANK SECTIONS (CSH05)
CSH05BL21
CSH05BL31
CSH05BL41
CSH05BL51
CSH05
CSH05BL61
CSH05BL81
CSH05BL101
BLANK SECTIONS (CSH07A)
CSH07BL21
CSH07BL31
CSH07BL41
CSH07BL51
CSHA07
CSH07BL61
CSH07BL81
CSH07BL101
BLANK SECTIONS (CSH14A)
CSH14BL21
CSH14BL31
CSH14BL41
CSH14BL51
CSHA14
CSH14BL61
CSH14BL81
CSH14BL101
90
5-1/2
7
14
*Additional length the accessory adds to the total installation length. ** Built-in duplex receptacle
available. Add model numbers suffix “-1” for bottom inlet - top outlet; add suffix “-3” for bottom inlet
- front outlet.
CONVECTION HEATERS
DECORATIVE SILL-HEIGHT CONVECTOR
DSH SERIES
AVAILABLE COLORS
Navajo Northern Charcoal
White
White
Gray
Neutral
Gray
Custom
Colors
Statuary
Bronze
Desert
Tan
Gloss
Black
NAVAJO WHITE
Aluminum
IDEAL SPACES | Offices; Hallways; Lobbies; Conference Rooms; Retail; Other Similar Areas with Floor-to-Ceiling Windows
COLORS | Neutral Gray; Charcoal Gray; Stainless Steel; Navajo White; Northern White; Statuary Bronze; Desert Tan; Black;
Custom Colors, Baked Enamel and Anodized Finishes Available
DIMENSIONS | Refer to specifications for dimensions available
•
Perfect for under-the-window heat loss and
condensation prevention
•
Locate at sill height (or lower) or run from mullion-to-mullion
•
Durable front cover constructed of 16-gauge steel
(optional 14-gauge available)
•
Wall-mounted design with extruded aluminum;
bottom or front inlet - top outlet discharge grille
Optional built-in controls include: line voltage
thermostat (SPST or DPST); two-stage thermostat;
power on/off switch; transformer relay; and power
relay (see specifications)
•
•
•
Units may contain 1-3 heating elements that yield a
broad range of heating capacity (see specifications)
Right- or left-hand entry/wiring flexibility with identical
pre-wired junction boxes at either end
•
•
Optional 1/4 in. mesh located under the discharge grille
to deter insertion of objects and restriction of airflow
Built-in wire way with factory-installed wiring rated
35 amps for CPH05 and 45 amps for CPH07
•
•
Blend into any décor with 8 standard color options or
custom finishes available upon request
Easy connection of supply wiring from bottom, rear
or end, as well as multiple wiring of adjacent heaters
from one entry point
•
Units can be mounted from wall-to-wall or as discrete
units in standard lengths of 28 in. to 10 ft.
•
For service, all internal parts are accessible by
removing cover
Front inlet models mount flush with floor; 125 to 250 watts per foot units can be positioned within 1-3/4 in. of floor; 375 to 750 watts per foot units can be positioned to within 3 in. of
floor; 5-1/2 in. and 7 in. high models are available with top outlet only; 14 in. models are available with top or front outlet.
CONTROL COMPARTMENT
(FOR THERMOSTAT & POWER
ON/OFF SWITCH)
NYLON BUSHINGS
HEATING ELEMENT
END CAP
(REQUIRED AT
END OF RUN)
HEATER HOUSING
WIREWAY
OVERHEAT PROTECTION
EXTRUDED ALUMINUM
DISCHARGE GRILLE
CONTROL COMPARTMENT
(FOR TRANSFORMER & POWER RELAY)
AIR INTAKE
For the latest models and information, please visit our website at www.qmarkmep.com
91
CONVECTION HEATERS
MODELS & SPECIFICATIONS | DSH05 (5-1/2” x 3” w/SINGLE ELEMENT)
TOTAL HEATING
CAPACITY
LENGTH
(FT)
CATALOG NO
DSH05A2125
DSH05A2188
DSH05A2250
DSH05A3125
DSH05A3188
DSH05A3250
DSH05A4125
DSH05A4188
DSH05A4250
DSH05A5125
DSH05A5188
DSH05A5250
DSH05A6125
DSH05A6188
DSH05A6250
DSH05A8125
DSH05A8188
DSH05A8250
DSH05A10125
DSH05A10188
DSH05A10250
AMPS
WATTS
PER FT.
TOTAL
WATTS
BTU/HR
120V
208V
240V
277V
347V
600V
125
188
250
125
188
250
125
188
250
125
188
250
125
188
250
125
188
250
125
188
250
250
375
500
375
546
750
500
750
1000
625
940
1250
750
1125
1500
1000
1500
2000
1250
1875
2500
853
1280
1706
1280
1925
2560
1706
2560
3412
2133
3208
4266
2560
3840
5120
3412
5120
6824
4266
6400
8532
2.1
3.1
4.2
3.1
4.7
6.2
4.2
6.2
8.3
5.2
7.8
10.4
6.2
9.4
12.5
-
1.2
1.8
2.4
1.8
2.7
3.6
2.4
3.6
4.8
3.0
4.5
6.0
3.6
5.4
7.2
4.8
7.2
9.6
6.0
9.0
12.0
1.0
1.6
2.1
1.6
2.4
3.1
2.1
3.1
4.2
2.6
3.9
5.2
3.1
4.7
6.3
4.2
6.3
8.3
5.2
7.8
10.4
0.9
1.4
1.8
1.4
2.0
2.7
1.8
2.7
3.6
2.3
3.4
4.5
2.7
4.1
5.4
3.6
5.4
7.2
4.5
6.8
9.0
0.7
1.1
1.4
1.1
1.6
2.2
1.4
2.2
2.9
1.8
2.7
3.6
2.2
3.2
4.3
2.8
4.3
5.8
3.6
5.4
7.2
0.4
0.6
0.8
0.6
0.9
1.2
0.8
1.2
1.7
1.0
1.6
2.1
1.2
1.9
2.5
1.7
2.5
3.3
2.1
3.1
4.2
2.3
3
4
5
6
8
10
NO. OF
ELEMENTS
SHIP WT.
(LBS)
1
12
1
13
1
17
1
22
1
26
1
35
1
43
MODELS & SPECIFICATIONS | DSH07 (7” x 5” w/MULTIPLE ELEMENTS)
TOTAL HEATING
CAPACITY
CATALOG NO
DSH07A2125
DSH07A2188
DSH07A2250
DSH07A2375
DSH07A2500
DSH07A2564
DSH07A2625
DSH07A2750
DSH07A3125
DSH07A3188
DSH07A3250
DSH07A3375
DSH07A3500
DSH07A3564
DSH07A3625
DSH07A3750
DSH07A4125
DSH07A4188
DSH07A4250
DSH07A4375
DSH07A4500
DSH07A4564
DSH07A4625
DSH07A4750
DSH07A5125
DSH07A5188
DSH07A5250
DSH07A5375
DSH07A5500
DSH07A5564
DSH07A5625
DSH07A5750
92
LENGTH
(FT)
2.3
3
4
5
WATTS
PER FT.
TOTAL
WATTS
BTU/HR
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
250
375
500
750
1000
1125
1250
1500
375
564
750
1125
1500
1690
1875
2250
500
750
1000
1500
2000
2250
2500
3000
624
940
1250
1875
2500
2820
3125
3750
853
1280
1706
2560
3412
3840
4266
5120
1280
1925
2560
3840
5120
5768
6400
7680
1706
2560
3412
5120
6824
7680
8532
10239
2133
3208
4266
6400
8532
9625
10665
12800
CONT. ON NEXT PAGE
AMPS
208V
240V
277V
347V
600V
(1 PH / 3 PH)
(1 PH / 3 PH)
(1 PH)
(1 PH)
(1 PH / 3 PH)
1.2 / 1.8 / 2.4 / 3.6 / 4.8 / 5.4 / 3.1
6.0 / 3.5
7.2 / 4.2
1.8 / 2.7 / 3.6 / 5.4 / 7.2 / 8.1 / 4.7
9.0 / 5.2
10.8 / 6.3
2.4 / 3.6 / 4.8 / 7.2 / 9.6 / 10.8 / 6.3
12.0 / 7.0
14.4 / 8.3
3.0 / 4.5 / 6.0 / 9.0 / 12.0 / 13.6 / 7.8
15.0 / 8.7
18.0 / 10.4
1.0 / 1.6 / 2.1 / 3.1 / 4.2 / 4.7 / 2.7
5.2 / 3.0
6.3 / 3.6
1.6 / 2.4 / 3.1 / 4.7 / 6.3 / 7.0 / 4.1
7.8 / 4.5
9.4 / 5.4
2.1 / 3.1 / 4.2 / 6.3 / 83 / 9.4 / 5.4
10.4 / 6.0
12.5 / 7.2
2.6 / 3.9 / 5.2 / 7.8 / 10.4 / 11.8 / 6.8.
13.0 / 7.5
15.6 / 9.0
0.9
1.4
1.8
2.7
3.6
4.1
4.5
5.4
1.4
2.0
2.7
4.1
5.4
6.1
6.8
8.1
1.8
2.7
3.6
5.4
7.2
8.1
9.0
10.8
2.3
3.4
4.5
6.8
9.0
10.2
11.3
13.5
0.7
1.1
1.4
2.2
2.9
3.2
3.6
4.3
1.1
1.6
2.2
3.2
4.3
4.8
5.4
6.5
1.4
2.2
2.9
4.3
5.8
6.5
7.2
8.6
1.8
2.7
3.6
5.4
7.2
8.1
9.0
10.8
0.4 / 0.6 / 0.8 / 1.2 / 1.7 / 1.9 / 1.1
2.1 / 1.2
2.5 / 1.4
0.6 / 0.9 / 1.2 / 1.9 / 2.5 / 2.8 / 1.6
3.1 / 1.8
3.7 / 2.1
0.8 / 1.2 / 1.7 / 2.5 / 3.3 / 3.7 / 2.1
4.2 / 2.4
5.0 / 2.9
1.0 / 1.6 / 2.1 / 3.1 / 4.2 / 4.7 / 2.7
5.2 / 3.0
6.2 / 3.6
NO. OF
ELEMENTS
SHIP WT.
(LBS)
1
2
15
3
1
2
20
3
1
2
26
3
1
2
3
33
CONVECTION HEATERS
MODELS & SPECIFICATIONS | DSH07 (7” x 5” w/MULTIPLE ELEMENTS)
TOTAL HEATING
CAPACITY
CATALOG NO
DSH07A6125
DSH07A6188
DSH07A6250
DSH07A6375
DSH07A6500
DSH07A6564
DSH07A6625
DSH07A6750
DSH07A8125
DSH07A8188
DSH07A8250
DSH07A8375
DSH07A8500
DSH07A8564
DSH07A8625
DSH07A8750
DSH07A10125
DSH07A10188
DSH07A10250
DSH07A10375
DSH07A10500
DSH07A10564
DSH07A10625
DSH07A10750
LENGTH
(FT)
6
8
10
WATTS
PER FT.
TOTAL
WATTS
BTU/HR
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
750
1125
1500
2250
3000
3380
3750
4500
1000
1500
2000
3000
4000
4500
5000
6000
1250
1875
2500
3750
5000
5640
6250
7500
2560
3840
5120
7680
10,239
11,535
12,800
15,358
3412
5120
6824
10,239
13,652
15,358
17,065
20,478
4266
6400
8532
12,800
17,065
19,250
21,330
25,600
CONT. FROM PREVIOUS PAGE
AMPS
208V
240V
277V
347V
600V
(1 PH / 3 PH)
(1 PH / 3 PH)
(1 PH)
(1 PH)
(1 PH / 3 PH)
3.6 / 5.4 / 7.2 / 10.8 / 14.4 / 16.3 / 9.4
18.0 / 10.4
21.6 / 12.5
4.8 / 7.2 / 9.6 / 14.4 / 19.2 / 21.6 / 12.5
24.0 / 13.9
28.8 / 16.7
6.0 / 9.0 / 12.0 / 18.0 / 24.0 / 27.1 / 15.7
30.0 / 17.4
36.1 / 20.8
3.1 / 4.7 / 6.3 / 9.4 / 12.5 / 14.1 / 8.1
15.6 / 9.0
18.8 / 10.8
4.2 / 6.3 / 8.3 / 12.5 / 16.7 / 18.8 / 10.8
20.8 / 12.0
25.0 / 14.5
5.2 / 7.8 / 10.4 / 15.6 / 20.8 / 23.5 / 13.6
26.0 / 15.0
31.3 / 18.1
2.7
4.1
5.4
8.1
10.8
12.2
13.5
16.2
3.6
5.4
7.2
10.8
14.4
16.2
18.1
21.7
4.5
6.8
9.0
13.5
18.1
20.4
22.6
27.1
2.2
3.2
4.3
6.5
8.6
9.7
10.8
12.9
2.9
4.3
5.8
8.6
11.5
13.0
14.4
17.3
3.6
5.4
7.2
10.8
14.4
16.2
18.0
21.6
1.2 / 1.9 / 2.5 / 3.7 / 5.0 / 5.6 / 3.2
6.2 / 3.6
7.5 / 4.3
1.7 / 2.5 / 3.3 / 5.0 / 6.7 / 7.5 / 4.3
8.3 / 4.8
10.0 / 5.8
2.1 / 3.1 / 4.2 / 6.2 / 8.3 / 9.4 / 5.4
10.4 / 6.0
12.5 / 7.2
NO. OF
ELEMENTS
1
2
CATALOG NO
DSH14A2125
DSH14A2188
DSH14A2250
DSH14A2375
DSH14A2500
DSH14A2564
DSH14A2625
DSH14A2750
DSH14A3125
DSH14A3188
DSH14A3250
DSH14A3375
DSH14A3500
DSH14A3564
DSH14A3625
DSH14A3750
DSH14A4125
DSH14A4188
DSH14A4250
DSH14A4375
DSH14A4500
DSH14A4564
DSH14A4625
DSH14A4750
LENGTH
(FT)
2.3
3
4
WATTS
PER FT.
TOTAL
WATTS
BTU/HR
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
250
375
500
750
1000
1125
1250
1500
375
564
750
1125
1500
1690
1875
2250
500
750
1000
1500
2000
2250
2500
3000
853
1280
1706
2560
3412
3840
4266
5120
1280
1925
2560
3840
5120
5768
6400
7680
1706
2560
3412
5120
6824
7680
8532
10239
39
3
1
2
52
3
1
65
2
3
MODELS & SPECIFICATIONS | DSH14 (14” x 5” w/MULTIPLE ELEMENTS)
TOTAL HEATING
CAPACITY
SHIP WT.
(LBS)
CONT. ON NEXT PAGE
AMPS
208V
240V
277V
347V
600V
(1 PH / 3 PH)
(1 PH / 3 PH)
(1 PH)
(1 PH)
(1 PH / 3 PH)
1.2 / 1.8 / 2.4 / 3.6 / 4.8 / 5.4 / 3.1
6.0 / 3.5
7.2 / 4.2
1.8 / 2.7 / 3.6 / 5.4 / 7.2 / 8.1 / 4.7
9.0 / 5.2
10.8 / 6.3
2.4 / 3.6 / 4.8 / 7.2 / 9.6 / 10.8 / 6.3
12.0 / 7.0
14.4 / 8.3
1.0 / 1.6 / 2.1 / 3.1 / 4.2 / 4.7 / 2.7
5.2 / 3.0
6.3 / 3.6
1.6 / 2.4 / 3.1 / 4.7 / 6.3 / 7.0 / 4.1
7.8 / 4.5
9.4 / 5.4
2.1 / 3.1 / 4.2 / 6.3 / 83 / 9.4 / 5.4
10.4 / 6.0
12.5 / 7.2
0.9
1.4
1.8
2.7
3.6
4.1
4.5
5.4
1.4
2.0
2.7
4.1
5.4
6.1
6.8
8.1
1.8
2.7
3.6
5.4
7.2
8.1
9.0
10.8
0.7
1.1
1.4
2.2
2.9
3.2
3.6
4.3
1.1
1.6
2.2
3.2
4.3
4.8
5.4
6.5
1.4
2.2
2.9
4.3
5.8
6.5
7.2
8.6
0.4 / 0.6 / 0.8 / 1.2 / 1.7 / 1.9 / 1.1
2.1 / 1.2
2.5 / 1.4
0.6 / 0.9 / 1.2 / 1.9 / 2.5 / 2.8 / 1.6
3.1 / 1.8
3.7 / 2.1
0.8 / 1.2 / 1.7 / 2.5 / 3.3 / 3.7 / 2.1
4.2 / 2.4
5.0 / 2.9
NO. OF
ELEMENTS
SHIP WT.
(LBS)
1
2
23
3
1
2
30
3
1
2
40
3
NOTE: All models are NON-STOCK, MADE-TO-ORDER. When ordering, specify quantity, catalog number, voltage, wattage, optional controls, and color. Consult sales representative for lead times.
OPTIONAL CONTROLS ON PAGE 98.
For the latest models and information, please visit our website at www.qmarkmep.com93
CONVECTION HEATERS
MODELS & SPECIFICATIONS | DSH14 (14” x 5” w/MULTIPLE ELEMENTS)
CATALOG NO
DSH14A5125
DSH14A5188
DSH14A5250
DSH14A5375
DSH14A5500
DSH14A5564
DSH14A5625
DSH14A5750
DSH14A6125
DSH14A6188
DSH14A6250
DSH14A6375
DSH14A6500
DSH14A6564
DSH14A6625
DSH14A6750
DSH14A8125
DSH14A8188
DSH14A8250
DSH14A8375
DSH14A8500
DSH14A8564
DSH14A8625
DSH14A8750
DSH14A10125
DSH14A10188
DSH14A10250
DSH14A10375
DSH14A10500
DSH14A10564
DSH14A10625
DSH14A10750
LENGTH
(FT)
5
6
8
10
ACCESSORIES
CATALOG NO.
DSH05-BL2*
DSH05BL3*
DSH05BL4*
DSH05BL5*
DSH05BL6*
DSH05BL8*
DSH05BL10*
DSH07BL2*
DSH07BL3*
DSH07BL4*
DSH07BL5*
DSH07BL6*
DSH07BL8*
DSH07BL10*
DSH14BL2*
DSH14BL3*
DSH14BL4*
DSH14BL5*
DSH14BL6*
DSH14BL8*
DSH14BL10*
Stand-Off
Bracket
WATTS
PER FT.
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
125
188
250
375
500
564
625
750
DESCRIPTION
28 in. Blank Section
3 ft. Blank Section
4 ft. Blank Section
5 ft. Blank Section
6 ft. Blank Section
8 ft. Blank Section
10 ft. Blank Section
28 in. Blank Section
3 ft. Blank Section
4 ft. Blank Section
5 ft. Blank Section
6 ft. Blank Section
8 ft. Blank Section
10 ft. Blank Section
28 in. Blank Section
3 ft. Blank Section
4 ft. Blank Section
5 ft. Blank Section
6 ft. Blank Section
8 ft. Blank Section
10 ft. Blank Section
SO1
SO2
TOTAL HEATING
CAPACITY
TOTAL
BTU/HR
WATTS
624
2133
940
3208
1250
4266
1875
6400
2500
8532
2820
9625
3125
10665
3750
12800
750
2560
1125
3840
1500
5120
2250
7680
3000
10,239
3380
11,535
3750
12,800
4500
15,358
1000
3412
1500
5120
2000
6824
3000
10,239
4000
13,652
4500
15,358
5000
17,065
6000
20,478
1250
4266
1875
6400
2500
8532
3750
12,800
5000
17,065
5640
19,250
6250
21,330
7500
25,600
AMPS
208V
(1 PH / 3 PH)
3.0 / 4.5 / 6.0 / 9.0 / 12.0 / 13.6 / 7.8
15.0 / 8.7
18.0 / 10.4
3.6 / 5.4 / 7.2 / 10.8 / 14.4 / 16.3 / 9.4
18.0 / 10.4
21.6 / 12.5
4.8 / 7.2 / 9.6 / 14.4 / 19.2 / 21.6 / 12.5
24.0 / 13.9
28.8 / 16.7
6.0 / 9.0 / 12.0 / 18.0 / 24.0 / 27.1 / 15.7
30.0 / 17.4
36.1 / 20.8
DSH05 Heaters
DSH07 Heaters
DSH14 Heaters
DSH05 Heaters
DSH07 Heaters
SHIP WT. (LBS)
10
13
17
21
25
32
42
14
18
24
30
36
48
60
22
29
38
48
57
76
95
1
1
NOTE: OPTIONAL CONTROLS ON PAGE 98. Outlet Mesh: Price per foot. 14-Gauge Front Cover:
add 10% to heater price. Standard color included in base price. Other colors available. View paint
policy on page 157. Maximum of 250 watts per ft. on front outlet models. When ordering, specify heater
catalog number, voltage, phase, suffix catalog number for built-in controls, color, and options. 2. If color
is not specified, front covers will be neutral grey. Front outlet models available only in 14 in. height and
125, 188 and 250 Wt./Ft. configuration. Outlet mesh is not available on front outlet models.
94
240V
(1 PH / 3 PH)
2.6 / 3.9 / 5.2 / 7.8 / 10.4 / 11.8 / 6.8.
13.0 / 7.5
15.6 / 9.0
3.1 / 4.7 / 6.3 / 9.4 / 12.5 / 14.1 / 8.1
15.6 / 9.0
18.8 / 10.8
4.2 / 6.3 / 8.3 / 12.5 / 16.7 / 18.8 / 10.8
20.8 / 12.0
25.0 / 14.5
5.2 / 7.8 / 10.4 / 15.6 / 20.8 / 23.5 / 13.6
26.0 / 15.0
31.3 / 18.1
277V
(1 PH)
2.3
3.4
4.5
6.8
9.0
10.2
11.3
13.5
2.7
4.1
5.4
8.1
10.8
12.2
13.5
16.2
3.6
5.4
7.2
10.8
14.4
16.2
18.1
21.7
4.5
6.8
9.0
13.5
18.1
20.4
22.6
27.1
CATALOG NO.
COMPATIBLE WITH
CONT. FROM PREVIOUS PAGE
DSH05ECL
DSH07ECL
DSH14ECL
DSH05ECR
DSH07ECR
DSH14ECR
DSH05FL3
DSH07FL3
DSH14FL3
DSH05FL6
DSH07FL6
DSH14FL6
DSH05FL9
DSH07FL9
DSH14FL9
DSH05FL12
DSH07FL12
DSH14FL12
DSH05FL18
DSH07FL18
DSH14FL18
DSH05IC*
DSH07IC*
DSH14IC
DSH05OC*
DSH07OC*
DSH14OC*
SHCC05
SHCC0714
347V
(1 PH)
1.8
2.7
3.6
5.4
7.2
8.1
9.0
10.8
2.2
3.2
4.3
6.5
8.6
9.7
10.8
12.9
2.9
4.3
5.8
8.6
11.5
13.0
14.4
17.3
3.6
5.4
7.2
10.8
14.4
16.2
18.0
21.6
600V
(1 PH / 3 PH)
1.0 / 1.6 / 2.1 / 3.1 / 4.2 / 4.7 / 2.7
5.2 / 3.0
6.2 / 3.6
1.2 / 1.9 / 2.5 / 3.7 / 5.0 / 5.6 / 3.2
6.2 / 3.6
7.5 / 4.3
1.7 / 2.5 / 3.3 / 5.0 / 6.7 / 7.5 / 4.3
8.3 / 4.8
10.0 / 5.8
2.1 / 3.1 / 4.2 / 6.2 / 8.3 / 9.4 / 5.4
10.4 / 6.0
12.5 / 7.2
NO. OF
ELEMENTS
SHIP WT.
(LBS)
1
2
50
3
1
2
60
3
1
2
80
3
1
2
100
3
DESCRIPTION
COMPATIBLE WITH
Left End Caps
All DSH Heaters
Right End Caps
All DSH Heaters
3 in. Filler Section
All DSH Heaters
6 in. Filler Section
All DSH Heaters
9 in. Filler Section
All DSH Heaters
12 in. Filler Section
All DSH Heaters
18 in. Filler Section
All DSH Heaters
Inside Corners
All DSH Heaters
Outside Corners
All DSH Heaters
Conduit Corners
All DSH Heaters
SHIP WT. (LBS)
1
1
1
1
1
1
1
2
3
2
3
5
3
4
6
4
5
8
5
6
9
2
4
6
1
2
4
4
5
CONVECTION HEATERS
ACCESSORIES
CATALOG NO
COMPATIBLE
WITH
HEIGHT
(IN)
DEPTH
(IN)
LENGTH
(IN)
ADDT’L
LENGTH* (IN)
DSH05
DSH07
DSH14
5-1/2
7
14
2-1/2
4-1/4
4-1/4
-
1/8
DSH05
DSH07
DSH14
5-1/2
7
14
2-1/2
4-1/4
4-1/4
-
1/8
DSH05
DSH07
DSH14
DSH05
DSH07
DSH14
DSH05
DSH07
DSH14
DSH05
DSH07
DSH14
DSH05
DSH07
DSH14
5-1/2
7
14
5-1/8
6-1/8
13-1/8
5-1/8
6-1/8
13-1/8
5-1/8
6-1/8
13-1/8
5-1/8
6-1/8
13-1/8
5-1/8
6-1/8
13-1/8
2-1/2
4-1/2
4-1/2
2-1/2
4-1/2
4-1/2
2-1/2
4-1/2
4-1/2
2-1/2
4-1/2
4-1/2
4
0-3
7
3-6
10
6-9
13
9-12
19
15-18
DSH05
DSH07
DSH14
5-1/8
6-1/8
13-1/8
2-1/2
4-1/2
4-1/2
4-1/2
6
6
3-3-1/2
5-5-1/2
5-5-1/2
DSH05
DSH07
DSH14
5-1/8
6-1/8
13-1/8
2-1/2
4-1/2
4-1/2
1
0-1/2
DSH05
DSH07
DSH14
-
2-5/8
3-5/8
2-1/2
3
-
4-3/4
6-3/4
3/4
3/4
3
3
-
3
28
36
48
60
72
96
120
28
36
48
60
72
96
120
5
28
36
48
60
72
96
120
28
36
48
60
72
96
120
5
28
36
48
60
72
96
120
28
36
48
60
72
96
120
LEFT END CAPS
DSH05ECL**
DSH07ECL**
DSH14ECL**
RIGHT END CAPS
DSH05ECR**
DSH07ECR**
DSH14ECR**
FILLER SECTIONS
DSH05FL3
DSH07FL3
DSH14FL3
DSH05FL6**
DSH07FL6**
DSH14FL6**
DSH05FL9**
DSH07FL9**
DSH14FL9**
DSH05FL12**
DSH07FL12**
DSH14FL12**
DSH05FL18**
DSH07FL18**
DSH14FL18**
INSIDE CORNERS
DSH05IC1
DSH07IC1
DSH14IC1
OUTSIDE CORNERS
DSH05OC1
DSH07OC1
DSH14OC1
CONDUIT CORNERS
SHCC05
SHCC07
SHCC14
STAND-OFF BRACKETS
SO1
DSH05A
SO2
DSH07A
BLANK SECTIONS (CSH05)
DSH05BL21
DSH05BL31
DSH05BL41
DSH05BL51
DSH05
DSH05BL61
DSH05BL81
DSH05BL101
BLANK SECTIONS (CSH07A)
DSH07BL21
DSH07BL31
DSH07BL41
DSH07BL51
DSHA07
DSH07BL61
DSH07BL81
DSH07BL101
BLANK SECTIONS (CSH14A)
DSH14BL21
DSH14BL31
DSH14BL41
DSH14BL51
DSHA14
DSH14BL61
DSH14BL81
DSH14BL101
5-1/2
7
14
*Additional length the accessory adds to the total installation length. **Built-in duplex receptacle
available. Add model numbers suffix “-1” for bottom inlet - top outlet; add suffix “-3” for bottom inlet
- front outlet.
For the latest models and information, please visit our website at www.qmarkmep.com95
CONVECTION HEATERS
COMMERCIAL SLOPE-TOP CONVECTOR
ST SERIES
AVAILABLE COLORS
NEMA 4X Models
The NEMA 4X series units are
designed to withstand wet (e.g. food
processing, breweries) or corrosive
(e.g. wastewater treatment plants,
indoor swimming pools) environments.
These units are constructed with
rugged 16-gauge stainless steel back
and front covers.
Navajo Northern Charcoal
White
White
Gray
Neutral
Gray
Custom
Colors
Statuary
Bronze
Desert
Tan
Gloss
Black
NEMA 4X MODEL
STAINLESS STEEL
Aluminum
IDEAL SPACES| (STANDARD) Offices; Corridors; Lobbies; Maintenance Rooms; Stairwells; Other Similar Spaces
(NEMA 4x) Food Processing Areas; Dairies; Breweries; Locker Rooms; Stadium Dugouts; Other Areas
Subject To High Pressure Hosing and/or Wet Conditions
COLORS | Neutral Gray; Charcoal Gray; Aluminum; Navajo White; Northern White; Statuary Bronze; Desert Tan; Gloss Black;
Custom Colors Available
DIMENSIONS | See specifications
•
NEMA 4X model* consists of stainless steel design rated
for washdown and corrosive environments
•
Attractive 45° sloped top discourages use of heater
as a shelf or a “stepstool”
•
Designed to mount on wall at sill height (or lower) and
can be positioned directly on floor. End of unit can be
positioned against adjacent sidewall if desired
•
Units can be mounted from wall-to-wall or as discrete
units in standard lengths of 28 in. to 10 ft.
•
Front cover fabricated from 16-gauge steel; back cover
is constructed of 18-gauge steel
•
Optional built-in controls include: thermostat;
disconnect switch; transformer relay; and power relay
(see specifications)
•
Thermal limit switch with linear type (full length) sensing
bulb provides constant protection against overheating
from any cause. Switch will automatically reset when
normal operating temperatures are restored
•
Accessories include complete line of matching splice
sections, inside and outside corners, and blank sections
•
Pre-wired and designed for either right- or left-hand
entry with connection of supply wiring from bottom,
rear or end, as well multiple wiring of adjacent heaters
from one entry point
•
All internal parts are accessible by removing cover for
easy service access
•
Elements are long-life metal sheath type, anchored to
allow for quiet expansion and contraction
•
Baked enamel finishes that are compatible with all
interior decors
*Contact sales representative for more information on NEMA 4X models.
DIMENSIONS
WATTS
96
A (IN)
B (IN)
NO. OF HOLES
500
28
-
-
750
36
-
-
1000
48
19
2
1250
60
16.68
4
1500
72
20.63
4
2000
96
21.5
6
2500
120
27.5
6
CONVECTION HEATERS
MODELS & SPECIFICATIONS
LENGTH
(FT)
CATALOG NO.
ST02
2.3
ST03
3
ST04
4
ST05
5
ST06
6
ST08
8
ST10
10
NOMINAL
WATTS/TT.
125
188
250
125
188
250
125
188
250
125
188
250
125
188
250
125
188
250
125
188
250
TOTAL HEATING
CAPACITY WATTS
250
375
500
375
546
750
500
750
1000
625
940
1250
750
1125
1500
1000
1500
2000
1250
1875
2500
BTU/HR.
120V
208V
240V
277V
347V
853
1280
1706
1280
1925
2560
1706
2560
3412
2133
3208
4266
2560
3840
5120
3412
5120
6824
4266
6400
8532
2.1
3.1
4.2
3.1
4.7
6.2
4.2
6.2
8.3
5.2
7.8
10.4
6.2
9.4
12.5
–
–
–
–
–
–
1.2
1.8
2.4
1.8
2.7
3.6
2.4
3.6
4.8
3.0
4.5
6.0
3.6
5.4
7.2
4.8
7.2
9.6
6.0
9.0
12.0
1.0
1.6
2.1
1.6
2.4
3.1
2.1
3.1
4.2
2.6
3.9
5.3
3.1
4.7
6.3
4.2
6.3
8.3
5.2
7.8
10.4
0.9
1.4
1.8
1.4
2.0
2.7
1.8
2.7
3.6
2.3
3.4
4.5
2.7
4.1
5.4
3.6
5.4
7.2
4.5
6.8
9.0
–
1.4
1.1
1.6
2.2
1.4
2.2
2.9
1.8
2.7
3.6
2.1
3.2
4.3
2.9
4.3
5.8
3.6
5.4
7.2
600V
–
–
SHIP WT.
(LBS.)
12
–
15
1.3
1.7
1.0
1.6
2.1
1.3
1.9
2.5
1.7
2.5
3.3
2.1
3.1
4.2
19
24
26
37
45
BUILT-IN CONTROLS & ACCESSORIES
OPTIONAL BUILT-IN
CONTROLS 5
RATINGS & DESCRIPTIONS 2
Single-Pole Thermostat
Rated 24 amps @ 120-240 VAC and 22 amps @ 277 VAC. Pilot duty rating of 125 VA (all voltages).
60-120°F temperature range; adjustable through outlet grille-tamper-resistant
2T*
Double-Pole
Thermostat
Rated 24 amps @ 120-240 VAC and 22 amps @ 277 VAC. Pilot duty rating of 125 VA (all voltages).
60-120°F temperature range; adjustable through outlet grille-tamper-resistant. (See Note 1 for amperage restrictions.)
DS*
Power On/Off Switch
Double-pole, rated 20 amp @ 120-277 VAC
Transformer Relay
Single-pole, low voltage relay with built-in transformer (24 VAC control), rated 25 amps @ 120-240 VAC and 22 amps @
277 VAC. 17 amps @ 347V , 12 amps @ 600V. Not available on 3-phase heaters
Power Relay
Single-pole magnetic relay, rated 18 amps @ 120-600 VAC. (See Note 3) Specify control voltage.
Rated 24 amps @ 120-240 VAC and 22 amps @ 277 VAC. Pilot duty rating of 125 VA - all voltages (See Note 3)
SUFFIX ADDITION TO
BASIC CATALOG NO. 4
T*
TR*
PR*
ICSTIC
2
Inside corner (requires additional wall space - use with ST model only)
ICSTOC
2
Outside corner (requires additional wall space - use with ST model only)
ICSTJS
1
Splice plate wide, coverage gap up to 1/2 in. (use with ST model only)
STO2BS
-
2 ft. Blank Section (unheated section)
STO4BS
-
4 ft. Blank Section (unheated section)
STO6BS
-
6 ft. Blank Section (unheated section)
STO8BS
-
8 ft. Blank Section (unheated section)
S
T
0
Series Name
02
04
06
08
10
=
=
=
=
=
2.3 ft.
4 ft.
6 ft.
8 ft.
10 ft.
03
05
07
09
=
=
=
=
3
5
7
9
ft.
ft.
ft.
ft.
125 w/ft. | 188 w/ft. | 250 w/ft.
4
2
5
0
2
4
1
HOW TO ORDER
SLOPE-TOP CONVECTION
HEATERS - ST SERIES
CONTROLS
NO. OF PHASES
VOLTS
WATT DENSITY
PRODUCT
CABINET LENGTH
NOTE: For 347V and 600V units options T, 2T, DS, are not available. Specify PDT as the suffix for a thermostat. *Factory built-in. Add suffix to heater catalog number. 1) A control combination is not available on
heaters that have an amperage draw which exceeds the rated limit of the lowest rated control. 2) For non-standard controls or combinations, contact factory. 3) Specify holding coil voltage where applicable.
D
S
T=
2T =
DS =
TR =
PR =
Single-Pole Thermostats
Double-Pole Thermostats
Power On/Off Switch
Transformer Relay
Power Relay
PE = Pneumatic/Electric Switch
2ST = Two-stage thermostat
PDT = Pilot-Duty Thermostat
(347V & 600V)
1= single-phase
12 = 120V | 20 = 208V | 24 = 240V | 27 = 277V | 34 = 347V | 60 = 600V
For the latest models and information, please visit our website at www.qmarkmep.com97
CONVECTION HEATERS
CONTROLS FOR CONVECTOR HEATERS
CATALOG NO.
DESCRIPTION
BLANK CONTROL SECTION 1
DBA3BCSF
Control Section, Front Inlet, 3-5/8 x 6 x 28 in.
DBA3BCSB
Control Section, Bottom Inlet, 3-5/8 x 6 x 28 in.
SHABCSF
Control Section, Front Inlet, 3-5/8 x 7 x 28 in.
SHABCSB
Control Section, Bottom Inlet, 3-5/8 x 7 x 28 in.
CSH07BCS1
Commercial Style, 7 in. High Bottom Inlet/Top Outlet
CSH14BCS1
Commercial Style, 14 in. High Bottom Inlet/Top Outlet
CSH14BCS3
Commercial Style, 14 in. High Bottom Inlet/Front Outlet
DSH07BCS1
Commercial Style, 7 in. High, Bottom Inlet/Top Outlet
DSH14BCS1
Commercial Style, 14 in. High, Bottom Inlet/Top Outlet
DSH07BCS2
Decorative Style, 7 in. High, Front Inlet/Top Outlet
DSH14BCS2
Decorative Style, 14 in. High, Front Inlet/Top Outlet
CIRCUIT BREAKERS 2
1CB2P30
(1) Three-Pole Circuit Breaker Rated 30 Amps @ 208, 240, 277 VAC
1CB2P60
(1) Two-Pole Circuit Breaker Rated 60 Amps @ 208, 240, 277 VAC
1CB3P30
(1) Three-Pole Circuit Breaker Rated 30 Amps @ 208, 240, 277 VAC
1CB3P60
(1) Three-Pole Circuit Breaker Rated 60 Amps @ 208, 240, 277 VAC
2CB2P30
(2) Two-Pole Circuit Breaker Rated 30 Amps @ 208, 240, 277 VAC
2CB2P60
(2) Two-Pole Circuit Breaker Rated 60 Amps @ 208, 240, 277 VAC
2CB3P30
(2) Three-Pole Circuit Breaker Rated 30 Amps @ 208, 240, 277 VAC
2CB3P60
(2) Three-Pole Circuit Breaker Rated 60 Amps @ 208, 240, 277 VAC
CONTROL TRANSFORMER, 50 VA RATING 3
TR24
Low Voltage Transformer, 24V Secondary
PNEUMATIC CONTROL
Pneumatic Operated Electric Switch–SPDT switch rated
16A @ 120 VAC, 9A @ 208 VAC, 8A @ 240 VAC, 7A @ 277 VAC,
pilot duty 125 VA @ 24-277 VAC, pressure 0 - 20 PSIG
PE
THERMOSTAT & RECEPTACLE
1PDT
Single-Pole Pilot Duty Thermostat, 60°-120°F Temperature Range–125 VA Rating
2PDT
Two-Stage Pilot Duty Thermostat, 60°-120°F Temperature Range–125 VA Rating.
Available on 2- or 3-element, single-phase heaters only.
2ST
Two-Stage Thermostat 60-120°F temperature range, adjustable through outlet
grille-tamper-resistant. Available on 2- or 3-element, single phase heaters only.
R3
120V Receptacle Duplex receptacle, 120V/20A, mounting in left or right end cap
of 6, 9, 12 or 18-in. filler sections only.
POWER ON/OFF SWITCH
DS
Pilot Duty Power On/Off Switch; Double-Pole (Disconnects relay holding coil circuit)
SCR CONTROLS
M90525A
Master SCR Control Rated 25 Amps @120 - 480V AC.
Master units accept 0 -10V DC, 4-20mA, or 135 OHM proportional control inputs.
M90548A
Master SCR Control Rated 48 Amps @120 - 480V AC
M90548A-2
Master SCR Control Rated 48 Amps @120 - 480V AC
SCR SLAVE CONTROLLER
S90525A
SCR Slave unit controller. Rated 25 Amps.
S90548A
SCR Slave unit controller. Rated 48 Amps
SCR THERMOSTAT
T90613V
98
Provides a proportional 2-10 VDC output for controlling
0-100% of the connected load to each Master 4.
Two types of control sections are available; a relay
control section which may have Power Relays, Circuit
Breakers, Thermostat, Pilot Duty Disconnect Switch,
P.E. Switch, or Control Transformer. An SCR Control
Section which may have Master and Slave SCR’s
with an SCR type thermostat. Control sections are 28
inches long and available in 7-inch high and 14-inch
high models plus the DBA. To develop a complete
catalog number, first start with the catalog number of the
selected Blank Control Section. Example: CSH07BCS1,
then add slash marks to separate the catalog
numbers that describe the individual controls
desired. Example: CSH07BCS1/M630/2CB3P30/PE.
This catalog number would be for a 5-inch deep, 7-inch
high commercial type control section with six 30 amp
Power Relays, two 3-pole 30 amp Circuit Breakers with
the unit controlled by a P.E. Switch. Also specify finish,
heater voltage, phase 1 or 3, and control voltage.
NOTE:
Each SCR incorporates its own zero-firing logic, providing any
combination or connection arrangement for single or three phase
applications. 25A single phase SCR can be mounted in the ASL
aluminum convector. Each Master and Thermostat will require 24V AC
Transformer. Specify holding coil voltage where applicable. On all 5 in.
high steel convectors the two-pole thermostat must go in the right hand
junction box (TR must mount in RH junction box. 2T+TR are invalid in
5 in. high steel convectors).
(1) Blank control sections are subject to the same color selections and
pricing as the appropriate matching heater. (2) Not available in DBA
control sections. (3) For use with DSH, CSH, and DPH end caps and
filler sections only. (4) Maximum of 8 SCRs is the limit for one thermostat
output signal.
** For use with DSH and CSH end caps and filler sections only.
BASEBOARD HEATERS
99
BASEBOARD HEATERS
ELECTRIC BASEBOARD HEATER|2500 SERIES
AVAILABLE COLORS
Northern
White
Navajo
White
NORTHERN WHITE
IDEAL SPACES | Bedrooms; Living/Family Rooms; Kitchens; Bathrooms; Basements; Offices; Conference Rooms;
Hallways; Lobbies; Waiting Rooms
COLORS | Northern White; Navajo White
•
Ideal for basic, zoned Primary/Secondary heating
•
Low profile perfect for limited wall space
•
Durable, textured, powder coat finish retains attractive
appearance with all interior decors
•
•
Lead wires and knockouts allow quick field connection
from either end
•
Pre-notched marks for mounting guide
•
Built-in cable clamp in both large wiring compartments
Convection heat minimizes air flow, reducing flow of
bacteria and dust
•
UL-listed for installation on wall at floor level with
wall-to-wall carpeting
•
Chimney fin element designed for maximum air circulation
•
Instant heat at call of thermostat
•
Air flow directed away from walls to help prevent
wall streaking
•
High temperature safety limit
SUGGESTED
CONTROLS
view page 151
for more information
TH114A240DBA
MD26
100
DIMENSIONS | 6-3/4" H x 2-7/8" D (Length varies)
BASEBOARD HEATERS
MODELS & SPECIFICATIONS
CATALOG NO.
2542NW
25426NW
2543NW
2544NW
2545NW
2546NW
2548NW
25408NW
2512NW
25126NW
2513NW
2514NW
2515NW
2516NW
2502NW
25026NW
2503NW
2504NW
2505NW
2506NW
2508NW
25008NW
2572NW
25726NW
2573NW
2574NW
2575NW
2576NW
2578NW
25708NW
UPC
VOLTS
WATTS
AMPS
LENGTH (FT)
SHIP WT. (LBS)
0 98319 73002 2
0 98319 73006 0
0 98319 73010 7
0 98319 73014 5
0 98319 73018 3
0 98319 73022 0
0 98319 73025 1
0 98319 72982 8
0 98319 73000 8
0 98319 73004 6
0 98319 73008 4
0 98319 73012 1
0 98319 73016 9
0 98319 73020 6
0 98319 73001 5
0 98319 73005 3
0 98319 73009 1
0 98319 73013 8
0 98319 73017 6
0 98319 73002 1
0 98319 73024 4
0 98319 72981 1
0 98319 73003 9
0 98319 73007 7
0 98319 73011 4
0 98319 73015 2
0 98319 73019 0
0 98319 73023 7
0 98319 73026 8
0 98319 72983 5
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
120
120
120
120
120
120
208
208
208
208
208
208
208
208
277/240/208
277/240/208
277/240/208
277/240/208
277/240/208
277/240/208
277/240/208
277/240/208
400/300
500/376
750/564
1000/752
1250/940
1500/1128
2000/1504
2500/1880
400
500
750
1000
1250
1500
400
500
750
1000
1250
1500
2000
2500
400/300/225
500/376/282
750/564/423
1000/752/564
1250/940/705
1500/1128/846
2000/1504/1128
2500/1880/1410
1.7/1.5
2.1/1.9
3.2/2.8
4.2/3.7
5.2/4.6
6.3/5.5
8.4/7.3
10.5/9.1
3.4
4.2
6.3
8.4
10.5
12.6
2.0
2.4
3.6
4.8
6.0
7.3
9.7
12.0
1.5/1.3/1.1
1.8/1.6/1.4
2.7/2.4/2.1
3.7/3.2/2.8
4.6/4.0/3.4
5.5/4.7/4.1
7.3/6.3/5.5
9.1/7.9/6.8
2
2.6
3
4
5
6
8
8
2
2.6
3
4
5
6
2
2.6
3
4
5
6
8
8
2
2.6
3
4
5
6
8
8
5.2
6.3
7.5
10
11.5
14
18.5
18.5
5.2
6.3
7.5
10
11.5
14
5.2
6.3
7.5
10
11.5
14
18.5
18.5
5.2
6.3
7.5
10
11.5
14
18.5
18.5
CONTROLS & ACCESSORIES
UPC
DESCRIPTION
SHIP
WT.
(LBS)
TA1AW
0 98319 73041 1
SP Thermostat, rated 22A @ 120-277V
1
TA1TPAW
0 98319 73042 8
Tamper-Resistant Version of TA1AW
1
CATALOG
NO.
TA2AW
0 98319 73043 5
DP Thermostat, rated 22A @ 120-277V
1
TA2TPAW
0 98319 73044 2
Tamper-Resistant Version of TA2AW
1
HCA2415/20W
0 98319 73046 6
240V Load Transfer Switch, 20A
1
HCA1215/20W
0 98319 73045 9
120V Load Transfer Switch, 20A
1
RSA1224
0 98319 71480 0
120V/24V Transformer Relay, 25A
1
RSA2024
0 98319 71485 5
208V/24V Transformer Relay, 25A
1
RSA2424
0 98319 71490 9
240V/24V Transformer Relay, 25A
1
RSA2724
0 98319 71495 4
277V/24V Transformer Relay, 22A
1
RA1W
0 98319 73047 3
120V Duplex Receptacle
1
DSW2W
0 98319 73049 7
Double-Pole Power On/Off Switch
rated 20A @ 120-277V
1
NOTE: Unit and accessories represent Northern White finish. For Navajo White,
remove N suffix to catalog number (ex. 2544W). For high-altitude baseboard heater
(mounted above 7,500 ft.), add suffix “H” to catalog number. 8 ft. length baseboards must be
ordered in multiples of two pieces for shipment. FILLER SECTIONS
CATALOG NO.
FS12NW
UPC
DESCRIPTION
SHIP
WT.
(LBS.)
0 98319 73150 0
1 ft. Filler Section
2
FS24NW
0 98319 73151 7
2 ft. Filler Section
4
FS36NW
0 98319 73152 4
3 ft. Filler Section
6
FS48NW
0 98319 73153 1
4 ft. Filler Section
8
FSJ2NW
73154 8
2 in. Joiner Strip
.5
BLANK
SECTIONS
CATALOG NO.
UPC
DESCRIPTION
SHIP WT.
(LBS)
QMKCBDA2NW
6 85360 05959 4
2.6 ft. Blank Section
4
6 85360 05961 7
3 ft. Blank Section
5
7
PR24
0 98319 71367 4
Single-Pole Power Relay, 24VControl
rated 30A @ 120-240V, 23A @ 277V
1
QMKCBDA3NW
QMKCBDA4NW
6 85360 05963 1
4 ft. Blank Section
PR120
0 98319 71368 1
Same as PR24 except with 120V Control
1
QMKCBDA5NW
6 85360 05965 5
5 ft. Blank Section
9
ICANW
0 98319 73050 3
Inside Corner
1
QMKCBDA6NW
6 85360 05967 9
6 ft. Blank Section
11
RA1COMPW
0 98319 73048 0
Duplex Receptacle Cover only – carton of 10
1
QMKCBDA8NW
6 85360 05969 3
8 ft. Blank Section
14
For the latest models and information, please visit our website at www.qmarkmep.com101
BASEBOARD HEATERS
ELECTRIC HYDRONIC BASEBOARD HEATER|HBB SERIES
NAVAJO WHITE
IDEAL SPACES | Bedrooms; Living/Family Rooms; Kitchens; Bathrooms; Basements; Offices; Conference Rooms;
Hallways; Lobbies; Waiting Rooms; Day Cares; Geriatric Facilities
COLORS | Navajo White
•
Ideal for superior, efficient and zoned
Primary/Secondary comfort
•
UL-listed for installation flush to any wall and flat on
any floor type; pre-notched marks for mounting guide
•
Low profile ideal for limited wall space
•
•
Large element reservoir maximizes the volume of heat
storage fluid for prolonged comfort
Heavy-duty welded steel louvered grilles discourage
insertion of foreign objects
•
•
Gentle heat continues to radiate even after the thermostat
turns off due to the hydronic element retention qualities
Low surface temperatures safe for installations with
pets, children and carpet
•
High temperature safety limit
•
Hydronic element reduces on/off cycling of thermostat
maintaining even room comfort and reducing energy costs
•
Storage fluid maximizes convection, minimizing air flow,
reducing flow of bacteria and dust
•
Heavy-duty welded steel louvered grilles direct heat
outward into the room.
•
Corrosion resistant aluminum fins are pressure-fitted
to copper tubing to assure rapid heat transfer, air flow
•
Built-in wire way, lead wires, and knockouts allow
quick field connection from either end
•
Air flow is directed away from walls and into the room
to help prevent wall streaking & minimizes dry air
SUGGESTED
CONTROLS
view page 151
for more information
TL8230A1003/U
MD26
102
DIMENSIONS | 8-3/8" H x 2-15/16" D (Length varies)
BASEBOARD HEATERS
MODELS & SPECIFICATIONS
CATALOG NO.
UPC
VOLTS
WATTS
AMPS
HBB500
6 85360 03577 2
120
500
4.2
HBB508
6 85360 03580 2
208
500
2.4
HBB504
6 85360 03578 9
240/208
500/375
2.1/1.8
HBB750
6 85360 03581 9
120
750
6.3
HBB758
6 85360 03584 0
208
750
3.6
HBB754
6 85360 03582 6
240/208
750/563
3.1/2.7
HBB1000
6 85360 03562 8
120
1000
8.3
HBB1008
6 85360 03565 9
208
1000
4.8
HBB1004
6 85360 03563 5
240/208
1000/750
4.2/3.6
HBB1250
6 85360 03566 6
120
1250
10.4
HBB1258
6 85360 03569 7
208
1250
6
HBB1254
6 85360 03567 3
240/208
1250/938
5.2/4.5
HBB1500
6 85360 03570 3
120
1500
12.5
HBB1508
6 85360 03573 4
208
1500
7.2
HBB1504
6 85360 03571 0
240/208
1500/1125
6.3/5.8
HBB2008
6 85360 03576 5
208
2000
9.6
HBB2004
6 85360 03574 1
240/208
2000/1500
8.3/7.2
LENGTH (FT)
SHIP WT. (LBS)
2.3
10
2.8
12
3.8
15
4.8
19
5.8
22
7.8
30
CONTROLS & ACCESSORIES
CATALOG NO.
UPC
DESCRIPTION
SHIP WT. (LBS)
HBBT1
6 85360 03557 4
25 amp @ 120-277 VAC; Single-Pole Thermostat Snap-Action Type;
Field-Installed in Junction Box
1
HBBT2
6 85360 03559 8
25 amp @ 120-277 VAC; Double-Pole Thermostat Snap-Action Type;
Field-Installed in Junction Box
1
HBBT1TP
6 85360 03558 1
Same as Model HBBT1 except Tamper-Resistant
1
HBBT2TP
6 85360 03560 4
Same as Model HBBT2 except Tamper-Resistant
1
HBBAC*
6 85360 03538 3
Air Conditioner Outlet Section, 20 amps @ 208/240 VAC
2
HBBDR
6 85360 03542 0
Duplex Receptacle Section, 15 amps @ 120 VAC
2
HBBDSDR120
6 85360 14797 0
Double-Pole Disconnect Switch /120V Receptacle
3
HBBWS
6 85360 03561 1
8 in. Blank Wiring Section
1
HBBLVR0*
6 85360 03547 5
Low Voltage Relay Control Section, 25 amps @ 120 VAC
3
HBBLVR8*
6 85360 03550 5
Low Voltage Relay Control Section, 25 amps @ 208 VAC
3
HBBLVR4*
6 85360 03548 2
Low Voltage Relay Control Section, 25 amps @ 240 VAC
3
HBBCDS2
6 85360 03539 0
Double-Pole Power On/Off Switch Section
2
CBDBS2*
6 85360 01453 1
2 ft. Blank Section
6
CBDBS3*
6 85360 01454 8
3 ft. Blank Section
8
CBDBS4*
6 85360 01455 5
4 ft. Blank Section
11
CBDBS5*
6 85360 01456 2
5 ft. Blank Section
14
CBDBS6*
6 85360 01457 9
6 ft. Blank Section
16
CBDBS8*
6 85360 01458 6
8 ft. Blank Section
22
CBDCIC*
6 85360 01460 9
Inside Corner
1
CBDCOC*
6 85360 01461 6
Outside Corner
1
NOTE: *HBBAC - HBBDR - HBBLVR - HBBWS accessories add 8 in. to baseboard length.
For the latest models and information, please visit our website at www.qmarkmep.com103
BASEBOARD HEATERS
COMMERCIAL BASEBOARD HEATER|QMKC SERIES
NAVAJO WHITE
IDEAL SPACES | Bedrooms; Living/Family Rooms; Kitchens; Bathrooms; Basements; Offices; Conference Rooms;
Hallways; Lobbies; Waiting Rooms
COLORS | Navajo White
•
Commercial-grade 20-gauge cold rolled front cover and
brackets allow heater to withstand rigors of commercial
applications
•
High temperature safety limit
•
Pre-notched marks for mounting guide
•
Steel-sheathed heating element combines the durability
of a steel tubular heater with the excellent heat transfer
characteristics of aluminum fins
•
UL-listed for installation flush to any wall and flat on
any floor type
•
Ideal for basic, zoned primary/secondary heating
•
No fans; convection heat minimizes air flow, reducing
flow of bacteria and dust
•
Built-in wire-way facilitates end-to-end installation of
continuous-run heaters
•
Chimney-fin element designed for maximum air circulation
•
Large, pre-wired junction boxes at each end are provided
with knockouts in the rear, bottom, inside and outside
•
Air flow directed away from walls to help prevent
wall streaking
SUGGESTED
CONTROLS
view page 151
for more information
TH114A240DBA
MD26
104
DIMENSIONS | 8-3/8" H x 2-15/16" D (Length varies)
BASEBOARD HEATERS
MODELS & SPECIFICATIONS
CATALOG NO.
QMKC25126W
QMKC25026W
QMKC25426W
QMKC25726W
QMKC2513W
QMKC2503W
QMKC2543W
QMKC2573W
QMKC2514W
QMKC2504W
QMKC2544W
QMKC2574W
QMKC2515W
QMKC2505W
QMKC2545W
QMKC2575W
QMKC2516W
QMKC2506W
QMKC2546W
QMKC2576W
QMKC2508W
QMKC2548W
QMKC2578W
QMKC25008W
QMKC25408W
QMKC25708W
UPC
6 85360 06046 0
6 85360 06016 3
6 85360 06087 3
6 85360 06132 0
6 85360 06051 4
6 85360 06021 7
6 85360 06092 7
6 85360 06137 5
6 85360 06056 9
6 85360 06026 2
6 85360 06097 2
6 85360 06142 9
6 85360 06061 3
6 85360 06031 6
6 85360 06102 3
6 85360 06147 4
6 85360 06066 8
6 85360 06036 1
6 85360 06107 8
6 85360 06152 8
6 85360 06041 5
6 85360 06112 2
6 85360 06157 3
6 85360 06011 8
6 85360 06082 8
6 85360 06127 6
VOLTS
120
208
240/208
277/240/208
120
208
240/208
277/240/208
120
208
240/208
277/240/208
120
208
240/208
277/240/208
120
208
240/208
277/240/208
208
240/208
277/240/208
208
240/208
277/240/208
CONTROLS & ACCESSORIES
CATALOG
NO.
WATTS
500
500
500/376
500/376/282
750
750
750/564
750/564/423
1000
1000
1000/752
1000/752/564
1250
1250
1250/940
1250/940/705
1500
1500
1500/1128
1500/1128/846
2000
2000/1504
2000/1504/1128
2500
2500/1880
2500/1880/1410
UPC
DESCRIPTION
SHIP
WT.
(LBS)
AMPS
4.2
2.4
2.1/1.8
1.8/1.6/1.4
6.5
3.6
3.1/2.7
2.7/2.4/2.0
8.3
4.8
4.2/3.6
3.6/3.1/2.7
10.4
6.0
5.2/4.5
4.5/3.9/3.4
12.6
7.2
6.3/5.4
5.4/4.7/4.1
9.6
8.3/7.2
7.2/6.3/5.4
12.0
10.4/8.7
9.0/7.5/6.8
LENGTH (FT)
SHIP WT. (LBS)
2.6
7.8
3
9.0
4
11.5
5
13.0
6
15.5
8
20
8
20
FILLER SECTIONS
CATALOG NO.
UPC
DESCRIPTION
SHIP
WT.
(LBS.)
TA1AW
0 98319 73041 1
SP Thermostat, rated 22A @ 120-277V
1
FS12
0 98319 73150 0
1 ft. Filler Section
2
TA1TPAW
0 98319 73042 8
Tamper-Resistant Version of TA1AW
1
FS24
0 98319 73151 7
2 ft. Filler Section
4
TA2AW
0 98319 73043 5
DP Thermostat, rated 22A @ 120-277V
1
FS36
0 98319 73152 4
3 ft. Filler Section
6
TA2TPAW
0 98319 73044 2
Tamper-Resistant Version of TA2AW
1
FS48
0 98319 73153 1
4 ft. Filler Section
8
HCA2415/20W
0 98319 73046 6
240V Load Transfer Switch, 20A
1
FSJ2
73154 8
2 in. Joiner Strip
1/2
HCA1215/20W
0 98319 73045 9
120V Load Transfer Switch, 20A
1
RSA1224
0 98319 71480 0
120V/24V Transformer Relay, 25A
1
RSA2024
0 98319 71485 5
208V/24V Transformer Relay, 25A
1
RSA2424
0 98319 71490 9
240V/24V Transformer Relay, 25A
1
RSA2724
0 98319 71495 4
277V/24V Transformer Relay, 22A
1
RA1W
0 98319 73047 3
120V Duplex Receptacle
1
DSW2W
0 98319 73049 7
Double-Pole Power On/Off Switch
rated 20A @ 120-277V
1
PR24
0 98319 71367 4
Single-Pole Power Relay, 24VControl
rated 30A @ 120-240V, 23A @ 277V
1
PR120
0 98319 71368 1
Same as PR24 except with 120V Control
1
ICAW
0 98319 73050 3
Inside Corner
1
RA1COMPW
0 98319 73048 0
Duplex Receptacle Cover only – carton of 10
1
BLANK
SECTIONS
CATALOG NO.
UPC
DESCRIPTION
SHIP WT.
(LBS)
QMKCBDA2W
6 85360 05959 4
2.6 ft. Blank Section
4
QMKCBDA3W
6 85360 05961 7
3 ft. Blank Section
5
QMKCBDA4W
6 85360 05963 1
4 ft. Blank Section
7
QMKCBDA5W
6 85360 05965 5
5 ft. Blank Section
9
QMKCBDA6W
6 85360 05967 9
6 ft. Blank Section
11
QMKCBDA8W
6 85360 05969 3
8 ft. Blank Section
14
NOTE: For high-altitude baseboard heater (mounted above 7,500 ft.), add suffix “H” to
catalog number. 8 ft. length baseboards must be ordered in multiples of two pieces for
shipment.
For the latest models and information, please visit our website at www.qmarkmep.com105
BASEBOARD HEATERS
COMMERCIAL BASEBOARD HEATER|CBD SERIES
NAVAJO WHITE
IDEAL SPACES | Bedrooms; Living/Family Rooms; Kitchens; Bathrooms; Basements; Offices; Conference Rooms;
Hallways; Lobbies; Waiting Rooms
COLORS | Navajo White
•
Commercial-grade 20-gauge cold rolled front cover and
brackets allow heater to withstand rigors of commercial
applications
•
Steel-sheathed heating element combines the durability
of a steel tubular heater with the excellent heat transfer
characteristics of aluminum fins
•
Large, pre-wired junction boxes at each end are provided
with knockouts in the rear, bottom, inside and outside
•
Built-in wire-way facilitates end-to-end installation of
continuous-run heaters
•
Pre-notched marks for mounting guide
•
Junction boxes made of high-strength Lexan® to resist
scratches and wear marks
•
UL-listed for installation flush to any wall and flat on
any floor type
•
Heavy-duty welded steel louvered grilles discourage
insertion of foreign objects
•
No fans; convection heat minimizes air flow, reducing
flow of bacteria and dust
•
Ideal for basic, zoned primary/secondary heating
•
Chimney-fin element designed for maximum air circulation
•
High temperature safety limit
•
Air flow directed away from walls to help prevent
wall streaking
SUGGESTED
CONTROLS
view page 151
for more information
TL8230A1003/U
MD26
106
DIMENSIONS | 8-3/8" H x 2-15/16" D (Length varies)
BASEBOARD HEATERS
MODELS & SPECIFICATIONS
CATALOG NO.
CBD500
CBD508
CBD504
CBD507
CBD750
CBD758
CBD754
CBD757
CBD1000
CBD1008
CBD1004
CBD1007
CBD1250
CBD1258
CBD1254
CBD1257
CBD1500
CBD1508
CBD1504
CBD1507
CBD2008
CBD2004
CBD2007
UPC
VOLTS
WATTS
AMPS
6 85360 01477 7
6 85360 01480 7
6 85360 01478 4
6 85360 01479 1
6 85360 01481 4
6 85360 01484 5
6 85360 01482 1
6 85360 01483 8
6 85360 01462 3
6 85360 01465 4
6 85360 01463 0
6 85360 01464 7
6 85360 01466 1
6 85360 01469 2
6 85360 01467 8
6 85360 01468 5
6 85360 01470 8
6 85360 01473 9
6 85360 01471 5
6 85360 01472 2
6 85360 01476 0
6 85360 01474 6
6 85360 01475 3
120
208
240/208
277/240/208
120
208
240/208
277/240/208
120
208
240/208
277/240/208
120
208
240/208
277/240/208
120
208
240/208
277/240/208
208
240/208
277/240/208
500
500
500/375
500/375/282
750
750
750/562
750/562/422
1000
1000
1000/750
1000/750/562
1250
1250
1250/938
1250/938/704
1500
1500
1500/1125
1500/1125/844
2000
2000/1500
2000/1500/1125
4.2
2.4
2.1/1.8
1.8/1.6/1.4
6.3
3.6
3.1/2.7
2.7/2.3/2.0
8.3
4.8
4.2/3.6
3.6/3.1/2.7
10.4
6
5.2/4.5
4.5/3.9/3.4
12.5
7.2
6.4/5.4
5.4/4.7/4.1
9.6
8.3/7.2
7.2/6.3/5.4
BTU/HR.
LENGTH (FT)
SHIP WT. (LBS)
1706
2.3
8
2560
2.8
10
3413
3.8
13
4265
4.8
16
5120
5.8
20
6825
7.8
27
CONTROLS & ACCESSORIES
CATALOG NO.
UPC
DESCRIPTION
SHIP WT. (LBS)
HBBT1
6 85360 03557 4
25 amp @ 120-277 VAC; Single-Pole Thermostat Snap-Action Type;
Field-Installed in Junction Box
1
HBBT2
6 85360 03559 8
25 amp @ 120-277 VAC; Double-Pole Thermostat Snap-Action Type;
Field-Installed in Junction Box
1
HBBT1TP
6 85360 03558 1
Same as Model HBBT1 except Tamper-Resistant
1
HBBT2TP
6 85360 03560 4
Same as Model HBBT2 except Tamper-Resistant
1
HBBAC*
6 85360 03538 3
Air Conditioner Outlet Section, 20 amps @ 208/240 VAC
2
HBBDR
6 85360 03542 0
Duplex Receptacle Section, 15 amps @ 120 VAC
2
HBBDSDR120
6 85360 14797 0
Double-Pole Disconnect Switch /120V Receptacle
3
HBBWS
6 85360 03561 1
8 in. Blank Wiring Section
1
HBBLVR0*
6 85360 03547 5
Low Voltage Relay Control Section, 25 amps @ 120 VAC
3
HBBLVR8*
6 85360 03550 5
Low Voltage Relay Control Section, 25 amps @ 208 VAC
3
HBBLVR4*
6 85360 03548 2
Low Voltage Relay Control Section, 25 amps @ 240 VAC
3
HBBCDS2
6 85360 03539 0
Double-Pole Power On/Off Switch Section
2
CBDBS2*
6 85360 01453 1
2 ft. Blank Section
6
CBDBS3*
6 85360 01454 8
3 ft. Blank Section
8
CBDBS4*
6 85360 01455 5
4 ft. Blank Section
11
CBDBS5*
6 85360 01456 2
5 ft. Blank Section
14
CBDBS6*
6 85360 01457 9
6 ft. Blank Section
16
CBDBS8*
6 85360 01458 6
8 ft. Blank Section
22
CBDCIC*
6 85360 01460 9
Inside Corner
1
CBDCOC*
6 85360 01461 6
Outside Corner
1
NOTE: *HBBAC - HBBDR - HBBLVR - HBBWS accessories add 8 in. to baseboard length. For high-altitude baseboard heater (mounted above 7,500 ft.), add suffix “H” to catalog number. 8 ft. length
baseboards must be ordered in multiples of two pieces for shipment.
For the latest models and information, please visit our website at www.qmarkmep.com107
RADIANT HEATERS
109
RADIANT HEATERS
RADIANT CEILING PANELS | INTRODUCTION
Radiant technology saves energy over other systems by heating
people and objects, rather than all the air in a room or building.
People are comfortable at lower room temperatures with a
radiant system than with a hot air convective system comfortable in the 60s rather than in the 70s, and lower
thermostat settings can save on energy bills each year.
“Sunshine” type heating is a form of radiant heat that
provides heating comfort in much the same manner as
the sun. Heat energy, in form similar to light rays, travel
in a straight line from the heater to the nearest object,
where the energy is absorbed and the object becomes warm.
Some rays are reflected and strike other objects, warming them also.
In non-radiant types of heating systems, it is necessary to warm
and circulate air in order to keep the temperature in a room at a
comfortable level. The warmer air warms the furniture and people in
the room. With radiant heating, furniture and people are heated directly.
The surrounding air eventually becomes warm, but the comfort
level is not dependent upon the air temperature.
Room temperature can be lowered 3-5°F while still
maintaining the same comfort level. Furniture, walls,
floors, etc., absorb some of the energy and act as a
heat bank, releasing some of the warmth into the room
during the “off” period of the normal “on-off” cycle of the
cove heaters.
The radiant CP Series is no exception, providing clean, gentle,
comfortable heat while allowing full usage of wall and floor spaces.
No noise. No moving parts. No maintenance. No ceilings, walls or
drapes to clean. No dried out air.
RADIANT CEILING PANELS | CP SERIES
IDEAL SPACES | Offices; Hallways; Lobbies; Conference Rooms; Retail Spaces; Locker Rooms; Laboratories;
Yoga Studios; Living Rooms; Bedrooms; Bathrooms; Basements
COLORS | White; Custom Colors and Silkscreens Available
110
DIMENSIONS | 24 x 24" and 24 x 48"
•
Ideal for invisible, primary or supplemental comfort
•
•
Perfect for offsetting perimeter heat losses or providing
primary heat to an entire space
Encapsulated casted element assures uniform
temperatures across surface and unit longevity
•
•
Full line of custom panels available upon request
(see specifications on next page)
Includes ground wire and 48 in. lead wires housed
in flexible metal conduit
•
•
Unit comes standard with 48 in. of 1/2 in. flexible
metal conduit and J-Box connector
All panels come standard with combination
Earthquake/T-bar grip clips
•
•
Insulation - Made of 1 in., 1 lb. density,
high-temperature fiberglass
Hanging Clips provide holes for support chains, or
can be folded over T-Bar to reduce lateral movement
•
•
Galvanized or aluminized steel housing
Constructed of fire retardant materials; no fire or
hazardous rating
RADIANT HEATERS
MODELS & SPECIFICATIONS | STANDARD
CATALOG NO.
CP251
CP258
CP252
CP257
CP253
CP311
CP318
CP312
CP317
CP313
CP371
CP378
CP372
CP377
CP373
CP501
CP508
CP502
CP507
CP503
CP621
CP628
CP622
CP627
CP623
CP751
CP758
CP752
CP757
CP753
UPC
6 85360 01658 0
6 85360 01663 4
6 85360 01659 7
6 85360 01662 7
6 85360 01660 3
6 85360 01669 6
6 85360 01674 0
6 85360 01670 2
6 85360 01671 9
6 85360 01673 3
6 85360 01675 7
6 85360 01685 6
6 85360 01676 4
6 85360 01677 1
6 85360 01684 9
6 85360 01691 7
6 85360 01696 2
6 85360 01692 4
6 85360 01695 5
6 85360 01693 1
6 85360 01697 9
6 85360 01707 5
6 85360 01698 6
6 85360 01706 8
6 85360 01699 3
6 85360 01713 6
6 85360 01718 1
6 85360 01714 3
6 85360 01717 4
6 85360 01715 0
VOLTS
120
208
240
277
347
120
208
240
277
347
120
208
240
277
347
120
208
240
277
347
120
208
240
277
347
120
208
240
277
347
WATTS
250
250
250
250
250
310
310
310
310
310
375
375
375
375
375
500
500
500
500
500
625
625
625
625
625
750
750
750
750
750
AMPS
2.1
1.2
1.0
0.9
0.7
2.6
1.5
1.3
1.1
0.9
3.1
1.8
1.6
1.4
1.1
4.2
2.4
2.1
1.8
1.4
5.2
3.0
2.6
2.3
1.8
6.3
3.6
3.1
2.7
2.1
SIZE (IN)
24x24
24x24
24x24
24x24
24x24
24x24
24x24
24x24
24x24
24x24
24x24
24x24
24x24
24x24
24x24
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
SHIP WT. (LBS.)
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
ACCESSORIES | STANDARD
CATALOG NO.
QSF2424
QSF2448
QRF2424
QRF2448
UPC
6 85360 20184 3
6 85360 20185 0
6 85360 20186 7
6 85360 20187 4
DESCRIPTION
Surface Mounting Frame for 24” x 24” Panels
Surface Mounting Frame for 24” x 48” Panels
Recess Mounting Frame for 24” x 24” Panels
Recess Mounting Frame for 24” x 48” Panels
NOTE: Heating panels do not have a fire or hazardous rating, but construction is of
fire retardant materials. Panels normally are treated like light fixtures. If necessary,
acoustical tile can be placed on top of the panels.
For the latest models and information, please visit our website at www.qmarkmep.com111
RADIANT HEATERS
ADDITIONAL FEATURES | MADE-TO-ORDER
TEGULAR (revealed edge): Tegular systems may utilize a standard grid with
a 10/16 in. cross-T or a “fine line” grid with a 9/16 in. cross-T. The acoustical title
is notched to hang below the grid creating the revealed edge. Tegular panels
are built with a support angle on all four sides to allow the panel front to drop
flush with the finished ceiling. Tegular and Fine line Tegular panels are supplied
standard with universal mounting clips installed for support chain.
SILKSCREEN: Radiant heating panels can be silk screened to provide an
architectural blend with leading acoustical tiles. For T-bar, concealed spline and
Tegular ceiling systems.
CUSTOM COLORS: Radiant heating panels can be painted any color
desired with high temperature acrylic paints without affecting panel performance.
Radiant energy is emitted from heating panels in the 8-10 micron wavelength
range. One of the principal characteristics of the wavelength is that it is not
color selective as are shorter wavelengths. Consequently, the surface color of
the panel is unimportant to heating efficiency and can be considered solely in the
light of aesthetics.
PANEL FRONTS FOR CONTINUOUS CEILING LINE: To provide a continuous
ceiling line around the perimeter of a building, the factory can provide panel fronts
to be interspersed between the functioning heating panels.
CONTROLS: P/E Switches - factory prewired to heaters. 20 amps - 120V, 240V,
208V and 277V. Power Relay - factory prewired to heaters. 30 amps single-pole
with 24V, 120V, 208/240V or 277V holding coil voltages.
LONGER FLEXIBLE CONDUIT: Panels will replace the standard 48 in.
greenfield with up to 11 ft. of 1/2 in. flexible conduit.
STAINLESS STEEL CONSTRUCTION: Special stainless steel panels are
available for chlorine storage areas. Panels will be equipped with seal tight
connectors and silicone sealed. If orders call for stainless steel construction the
panels will be painted unless specified different.
FACTORY SILICONE-SEALED PANELS: Exterior moisture and condensation
do not affect heating panel performance, but water inside the unit can cause the
panel to fail. Panels being used in locker rooms and swimming pool areas should
be totally sealed with silicone at the factory before shipment, if there is a chance
of moisture above the ceiling, then seal tight conduit and seal tight connectors
also should be used.
SEAL-TIGHT FLEXIBLE CONDUIT & CONNECTORS: Radiant ceiling panels
come with 1/2 in. greenfield flexible conduit and straight connectors. Seal-tight
connectors and conduit can be substituted at the factor if panels are to be used
in high moisture areas or if required by local electrical codes.
HEAVIER DUTY PANELS: For special installation the factory can use heavier
gauge steel in the construction of the panels.
MODULAR WIRING SYSTEMS: For specific jobs, the factor can substitute
modular connector for the straight connectors and pig tails that are standard
equipment.
MODELS & SPECIFICATIONS | MADE-TO-ORDER
HOW TO ORDER
WATTS PER PANEL - NOMINAL PANEL LENGTH
PANEL WIDTH (IN)
WATT DENSITY
10-13
14-17
18-21
22-28
High
Med
Low
High
Med
Low
High
Med
Low
High
Med
Low
24-35 (IN)
36-47 (IN)
48-59 (IN)
155
130
105
235
195
155
315
260
210
375
310
250
235
195
155
350
295
235
470
390
315
565
470
375
315
260
210
470
390
315
625
520
415
750
625
500
60-71 (IN)
390^
325^
260^
585^
490^
390^
780
650
520
940
785
625
72-83 (IN)
84-95 (IN)
96 (IN)
940^^
780^^
625^^
1125
940
750
1315
1095
875
1500
1250
1000
ACCESSORIES | MADE-TO-ORDER
CUSTOM PANEL OPTIONS
SILKSCREEN
CUSTOM PAINT
TEGULAR or FINELINE TEGULAR
When ordering, please specify panel size
as exact or nominal (panels can be up to
7/1 in. less in size).
^ maximum panel length = 60 in.
^^ maximum panel length = 72 in.
Catalog No. for surface mounting frames
(QSF) and recess mounting frames (QRF)
begin with their respective prefix followed
by width and length of panel.
DESCRIPTION
To Provide An Architectural Blend With Leading Ceiling Tile, 2x5 ft. Max. There is a Panel Charge Each Time.
If Manufacturer Does Not Have A Tile Pattern Screen There Is An Additional One-Time Charge. See Pricebook.
Solid Color Custom Painted Panel - To Provide An Accent Strip
Tegular - Reveal Edge Detail - (For 15/16 in. Grid) Construction Fineline Tegular - Reveal Edge Detail - (For 9/16 in. Grid)
EXTRA-LENGTH GREENFIELD FLEX
(1/2” x 48” STANDARD)
Custom Flexlength 1/2 x 60 in. / 72 / 84 / 96 / 108 / 120 / 132 in.
SEALTITE CONDUIT
Custom Flexlength 1/2 x 60 in. / 72 / 84 / 96 / 108 / 120 / 132 in.
SILICONE SEAL
STAINLESS STEEL CONSTRUCTION
HEAVY DUTY CONSTRUCTION
FILLER PANELS
PE SWITCH
POWER CONTACTOR
NOTE: Products are made-to-order and cannot be returned.
112
The catalog number for custom panels
begins with the QT prefix followed:
•
Watt Density (H, M, L)
•
Panel Width
•
Panel Length
•
Voltage (1=120V; 8=208V; 2=240V;
7=277V; 3=347V)
For example, a 13 x 36 in. 240V unit with a
high watt density would be QTH13362.
Seams Sealed For Added Moisture Protection. For Use In Shower Rooms And Above Pool Windows
Stainless Steel - 22-Gauge Front Panel, 24-Gauge Back Panel. Includes 1/2 x 48 in. Sealtite Flex And Silicone Seal
16-Gauge Galvanized Or Aluminized Steel Front Panel
18-Gauge Galvanized Or Aluminized Steel Back Panel
Finished To Match Standard, Silkscreen Or Custom Painted Panel. Does Not Contain An Element Or Flex Conduit.
Standard Construction: Front Only. Tegular / Fineline Tegular: Front And Back Only
Pneumatic Electric Switch
Power Contactor
RADIANT HEATERS
COVE HEATER | RCC SERIES
AVAILABLE COLORS
Birch
White
Dove
Gray
Desert
Tan
BIRCH WHITE
IDEAL SPACES | Offices; Hallways; Lobbies; Conference Rooms; Retail Spaces; Day Care Centers; Geriatric Facilities;
Laboratories; Living Rooms; Kitchens; Bedrooms; Bathrooms; Basements
COLORS | Birch White; Dove Grey & Desert Tan available upon request
DIMENSIONS | 4-3/16" H x 3" D (Length varies)
•
Ideal for primary or supplemental comfort heat
•
Easily wall-mounted; with all parts included
•
Perfect where wall space is limited and gentle
heat is desired
•
Provides clean, gentle, comfortable heat while allowing
full usage of wall and floor spaces
•
Extruded aluminum front panel provides a high
efficiency, textured, radiating surface
•
No noise. No moving parts. No maintenance.
No ceilings, walls or drapes to clean. No dried out air
•
Coated with high temperature textured paint, unit
radiates a majority of its heat energy from front surface
•
•
New profile and unique hanging system provide optimal
heat dissipation for uniform comfort
Dual Function Heating (Radiant and Convection):
remaining energy is “wiped off” by convection flow
behind and over the top of unit, circulating warm air
into the room - achieving balanced heating throughout
MODELS & SPECIFICATIONS
CATALOG NO.
RCC4508C
RCC4512C
RCC4524C
RCC6008C
RCC6012C
RCC6024C
RCC6027C
RCC7508C
RCC7512C
RCC7524C
RCC7527C
RCC9008C
RCC9012C
RCC9024C
RCC9027C
RCC10508C
RCC10512C
RCC10524C
RCC10527C
RCC12008C
RCC12012C
RCC12024C
RCC12027C
RCC15008C
RCC15024C
RCC15027C
RCC18008C
RCC18024C
RCC18027C
RCCT
RCCSPC
UPC
6 85360 14717 8
6 85360 14718 5
6 85360 14719 2
6 85360 14720 8
6 85360 14721 5
6 85360 14722 2
6 85360 14723 9
6 85360 14724 6
6 85360 14725 3
6 85360 14726 0
6 85360 14727 7
6 85360 14728 4
6 85360 14729 1
6 85360 14730 7
6 85360 14731 4
6 85360 14732 1
6 85360 14733 8
6 85360 14745 1
6 85360 14734 5
6 85360 14735 2
6 85360 14736 9
6 85360 14737 6
6 85360 14738 3
6 85360 14739 0
6 85360 14740 6
6 85360 14741 3
6 85360 14742 0
6 85360 14743 7
6 85360 14744 4
6 85360 06566 3
6 85360 14766 6
WATTS
VOLTS BTU/HR AMPS LENGTH (IN)
208V
2.2
34
450W
120V
1536
3.7
34
240V
1.9
34
208V
2.9
47
600W
120V
5.0
47
2048
240V
2.5
47
277V
2.2
47
208V
3.6
59
120V
6.2
59
750W
2560
240V
3.1
59
277V
2.7
59
208V
4.3
71
120V
7.5
71
900W
3072
240V
3.7
71
277V
3.2
71
208V
5.0
83
120V
8.8
83
1050W
3583
240V
4.4
83
277V
3.8
83
208V
5.8
94
120V
10.0
94
1200W
4095
240V
5.0
94
277V
4.3
94
208V
7.2
118
1500W
240V
5120
6.2
118
277V
5.4
118
208V
8.7
132
1800W
240V
6142
7.5
132
277V
6.5
132
Integral Thermostat: Range 45-90°F with Positive Off
Splice Plate Assembly
SHIP WT. (LBS)
4
6
7
8
9
10
13
15
1
2
NOTE: For Dove Gray add (DG) or for Desert Tan add (DT) to suffix of catalog number.
For the latest models and information, please visit our website at www.qmarkmep.com
113
RADIANT HEATERS
INFRARED HEATERS|INTRODUCTION
Infrared technology permits the heating of areas where it is impractical, either economically or physically, to heat air. The physics that causes
warm air to rise and cool air to fall are constantly working against forced air heating systems, particularly in outdoor or high ceiling areas. The
radiant heat energy emitted by infrared heaters is transferred direct to the people and objects under them. It is the same principle that allows
the sun to make a clear, cold day feel warm. The radiant energy from infrared heaters can be directed and focus in any direction to evenly
blanket people and equipment with comforting warmth, free from drafts and noisy fans or blowers.
•
•
•
•
•
•
Soft, efficient comfort: heat people and objects not the air for optimal energy efficiency
Energy savings: provides a low cost energy efficient alternative to propane/gas heat
Uniform, localized heating: provides instant, fully directional space heating
Clean, safe comfort: no moving air/parts, no dust, no combustion, no fumes
IPX5-rated; contemporary all-weather design
Low maintenance with no moving parts or filters, minimal servicing needed
INFRARED HEATERS|SELECTING THE RIGHT MODELS
Keep in mind these elements when selecting the correct infrared heater for your needs:
•
Type of application: area heating, snow melting, or spot heating
•
Type of environment: outdoors, indoors, marine or corrosive atmospheres
•
Design area: square footage, objects/people standing or sitting
•
Watt density required to maintain comfort
•
Mounting height
Contact your sales representative
for more information on which
infrared heaters will work for your
specific application.
The following are examples of heating patterns available. Consult your sales representative for information on which patterns are available for each product.
114
30°
SYMMETRICAL
60°
SYMMETRICAL
60°
ASYMMETRICAL
90°
SYMMETRICAL
IPX5
RATED
WEATHERRESISTANT
RADIANT HEATERS
IDEAL SPACES | Indoor Workshops; Garages; Indoor/Outdoor Patios/Terraces; Restaurants; Bus
Stops; Golf Ranges; Valets; Swimming Pools; Sports and Fitness Areas; Shipping/Loading Areas
NORTHERN WHITE
INFRARED PLUG-IN HEATER
QHRA11 SERIES
MODELS & SPECIFICATIONS
CATALOG NO.
QHRA11115W
UPC
6 85360 16371 0
COVERAGE AREA1
130 SF
VOLTS
120
AMPS
12.5
WATTS
1500
BTU/HR.
5115
DIMENSIONS (L x W x H)
17-15/16” x 3-1/2” x 5-1/8”
SHIP WT. (LBS)
4.2
NOTE: 1 May need multiple units for specific area. Consult MEP technical services for more information on Infrared System Design.
INFRARED PLUG-IN HEATER
QHRA66 SERIES
GLOSS BLACK
MODELS & SPECIFICATIONS
CATALOG NO.
QHRA66420B
UPC
6 85360 16380 2
COVERAGE AREA1
300 SF
VOLTS
240
AMPS
8.45
WATTS
2000
BTU/HR.
6824
DIMENSIONS (L x W x H)
20-1/16” x 6-1/4” x 8-1/12”
SHIP WT. (LBS)
6.6
NOTE: 1 May need multiple units for specific area. Consult MEP technical services for more information on Infrared System Design.
COMMERCIAL INFRARED HEATER|QVRC44 SERIES
GLOSS BLACK
QVRC4440DTG
QVRC4420SG
QVRC4440DWG
MODELS & SPECIFICATIONS
CATALOG NO.
QVRC4420SG
QVRC4440DTG
QVRC4440DWG
UPC
6 85360 16382 6
6 85360 16383 3
6 85360 16385 7
COVERAGE AREA1
300 SF
300 SF
300 SF
VOLTS
240
240
240
AMPS
8.4
16.7
16.7
WATTS
2000
4000
4000
BTU/HR.
6824
13648
13648
DIMENSIONS (L x W x H)
15-3/4” x 4-3/4” x 8-11/16”
15-3/4” x 5-1/8” x 13-3/4”
31-1/2” x 4-3/4” x 5-1/8”
SHIP WT. (LBS)
6.8
9
11
NOTE: 1 May need multiple units for specific area. Consult MEP technical services for more information on Infrared System Design.
HIGH-PERFORMANCE DESIGN
Qmark Infrared heaters optimize short wave infrared energy by means
of precisely designed parabolic reflectors, with more than 60% of
the heat is generated by the reflector and 40% by the tube. These
reflectors allow for fully directional, personalized comfort due to the fact
that heat radiation obeys the laws of optics both in terms of reflection
and refraction. The high frequency infrared energy reflects off the surface and heats people
and objects in the surrounding environment
to provide a blanket of
warmth, without waste
to the air. Our high performance symmetrical
reflectors provide measurable energy savings.
MOUNTING REQUIREMENTS
For the latest models and information, please visit our website at www.qmarkmep.com
115
RADIANT HEATERS
INFRARED HEATER
FRP/FRS SERIES
STATUARY BRONZE
IDEAL SPACES | Car Washes; Parking Garages; Arenas; Showrooms; Workshops;, Loading Docks; Aircraft Hangers;
Warehouses; Gymnasiums; Swimming Pools; Walkways; Entryways; Ski Resorts; Sports Arenas;
Driving Ranges; Bus Stops; Smoking Areas; Patios
ENCLOSURE TYPE | Painted Steel; Stainless Steel
ELEMENT TYPE* | Metal Sheathed; Quartz Tube and Quartz Lamp
REFLECTIVE ANGLE | 30° Symmetrical; 60° Symmetrical; 60° Asymmetrical; 90° Symmetrical
•
Ideal for indoor/outdoor, total or spot heating use
•
Two- and three-element design provide concentrated
heating capacity in single infrared radiant heater
•
Metal sheath, quartz tube or quartz lamp elements used
interchangeably provide flexibility necessary for multiple
application projects
•
•
FRP – 20-gauge galvanized steel enclosure and heater
support/wiring compartment; statuary bronze powder
coat finish
•
Heavy-gauge gold anodized reflectors offer a wide
selection of beam patterns
•
High quality finish and steel internal sheet metal
parts give excellent service under most operating
conditions, including coastal salt air and most
industrial atmospheres**
FRS – 20-gauge, stainless steel enclosure and heater
support/wiring compartment for applications requiring
additional corrosion resistance
NOTE: *Metal Sheathed: used indoors or outdoors in high-traffic areas; Quartz Tube and Quartz Lamp: used indoors and outdoors for snow melting and spot heating. **Finish not intended for direct salt
spray exposure in marine applications or highly corrosive greenhouse, swimming pool, chemical storage or industrial atmospheres. Maintain at least 5 ft. in radiant path, between bottom of heater and
combustible material. Pigtail element leads for a more positive connection in high-traffic areas where physical abuse.
MODELS & SPECIFICATIONS | 2-ELEMENT ENCLOSURE
CATALOG NO.
PAINTED
FRP223S
FRP226S
FRP226AS
FRP229S
FRP233S
FRP236S
FRP236AS
FRP239S
FRP243S
FRP246S
FRP246AS
FRP249S
UPC
6 85360 02931 6
6 85360 02846 0
6 85360 02839 2
6 85360 02854 5
6 85360 02870 5
6 85360 02886 6
6 85360 02878 1
6 85360 02894 1
6 85360 02907 8
6 85360 02917 7
6 85360 02912 2
6 85360 02922 2
CATALOG NO.
STAINLESS
FRS223S
FRS226S
FRS226AS
FRS229S
FRS233S
FRS236S
FRS236AS
FRS239S
FRS243S
FRS246S
FRS246AS
FRS249S
UPC
6 85360 03051 7
6 85360 03067 8
6 85360 03059 3
6 85360 03075 3
6 85360 03075 3
6 85360 03091 3
6 85360 03107 1
6 85360 03099 9
6 85360 03115 6
6 85360 03138 5
6 85360 03133 0
6 85360 03143 9
REFLECTIVE
ANGLE
30 Sym
60 Sym
60 Asym
90 Sym
30 Sym
60 Sym
60 Asym
90 Sym
30 Sym
60 Sym
60 Asym
90 Sym
HEIGHT
(IN)
WIDTH
(IN)
LENGTH
(IN)
SHIP WT.
LBS.
7.125
15
24
19
7.125
15
33
24
7.125
15
46
31
HEIGHT
(IN)
WIDTH
(IN)
LENGTH
(IN)
SHIP WT.
LBS.
7.125
15
24
23
7.125
15
33
31
7.125
15
46
39
MODELS & SPECIFICATIONS | 3-ELEMENT ENCLOSURE
CATALOG NO.
PAINTED
FRP323S
FRP326S
FRP326AS
FRP329S
FRP333S
FRP336S
FRP336AS
FRP339S
FRP343S
FRP346S
FRP346AS
FRP349S
116
UPC
6 85360 02935 1
6 85360 02951 1
6 85360 02943 6
6 85360 02959 7
6 85360 02975 7
6 85360 02991 7
6 85360 02983 2
6 85360 02999 3
6 85360 03012 8
6 85360 03025 8
6 85360 03020 3
6 85360 03030 2
CATALOG NO.
STAINLESS
FRS323S
FRS326S
FRS326AS
FRS329S
FRS333S
FRS336S
FRS336AS
FRS339S
FRS343S
FRS346S
FRS346AS
FRS349S
UPC
6 85360 03156 9
6 85360 03172 9
6 85360 03164 4
6 85360 03180 4
6 85360 03197 2
6 85360 03213 9
6 85360 03205 4
6 85360 03221 4
6 85360 03234 4
6 85360 03244 3
6 85360 03239 9
6 85360 03249 8
REFLECTIVE
ANGLE
30 Sym
60 Sym
60 Asym
90 Sym
30 Sym
60 Sym
60 Asym
90 Sym
30 Sym
60 Sym
60 Asym
90 Sym
RADIANT HEATERS
ELEMENT SELECTION CHART 1
CATALOG NO.
F2MS08208
F2MS08240
F2MS08277
F2MS08347
F2MS08480
F2MS08600
F2QT10208
F2QT10240
F2QT10277
F2QL16208
F2QL16240
F2QL16277
F2QL16347
F2QL16480
F2QL16600
F3MS15208
F3MS15240
F3MS15277
F3MS15347
F3MS15480
F3MS15600
F3QT15208
F3QT15240
F3QT15277
F3QT15347
F3QT15480
F3QT15600
F3QL25208
F3QL25240
F3QL25277
F3QL25347
F3QL25480
F3QL25600
F4MS20208
F4MS20240
F4MS20277
F4MS20347
F4MS20480
F4MS20600
F4QT20208
F4QT20240
F4QT20277
F4QT20347
F4QT20480
F4QT20600
F4QL36347
F4QL36480
F4QL36600
UPC
VOLTS
6 85360 03275 7
6 85360 03276 4
6 85360 03277 1
6 85360 03278 8
6 85360 03280 1
6 85360 03281 8
6 85360 03289 4
6 85360 03290 0
6 85360 03291 7
6 85360 03282 5
6 85360 03283 2
6 85360 03284 9
6 85360 03285 6
6 85360 03287 0
6 85360 03288 7
6 85360 03323 5
6 85360 03324 2
6 85360 03325 9
6 85360 03326 6
6 85360 03328 0
6 85360 03329 7
6 85360 03337 2
6 85360 03338 9
6 85360 03339 6
6 85360 03340 2
6 85360 03342 6
6 85360 03343 3
6 85360 03330 3
6 85360 03331 0
6 85360 03332 7
6 85360 03333 4
6 85360 03335 8
6 85360 03336 5
6 85360 03344 0
6 85360 03345 7
6 85360 03346 4
6 85360 03347 1
6 85360 03349 5
6 85360 03350 1
6 85360 03355 6
6 85360 03356 3
6 85360 03357 0
6 85360 03358 7
6 85360 03360 0
6 85360 03361 7
6 85360 03351 8
6 85360 03353 2
6 85360 03354 9
208
240
277
347
480
600
208
240
277
208
240
277
347
480
600
208
240
277
347
480
600
208
240
277
347
480
600
208
240
277
347
480
600
208
240
277
347
480
600
208
240
277
347
480
600
347
480
600
WATTS
850
1000
1600
1500
2-ELEMENT ENCLOSURE
TYPE
Metal
Sheath
Quartz
Tube
Quartz
Lamp
Metal
Sheath
1500
Quartz
Tube
2500
Quartz
Lamp
2000
Metal
Sheath
COMPATIBLE WITH
FRP22
(24 in. L)
FRS22
(24 in. L)
FRP32
(24 in. L)
FRS32
(24 in. L)
FRP23
(33 in. L)
FRS23
(33 in. L)
FRP33
(33 in. L)
FRS33
(33 in. L)
FRP24
(46 in. L)
MAXIMUM WATTAGE
SHIP WT. (LBS)
1
1
24”
33”
46”
METAL
SHEATH
QUARTZ
TUBE
QUARTZ
LAMP
1700
3000
4000
2000
3000
4000
3200
5000
7300
3-ELEMENT ENCLOSURE
MAXIMUM WATTAGE
1
24”
33”
46”
METAL
SHEATH
QUARTZ
TUBE
QUARTZ
LAMP
2500
4500
6000
3000
4500
6000
4800
7500
10,950
1
1
1
MOUNTING CLEARANCES
• 24 in. to vertical side walls
• 36 in. between heaters mounted
side by side. Heaters may be
mounted end to end
• 6 in. to ceiling
• 84 in. to floor
1
FRS24
(46 in. L)
2000
Quartz
Tube
3650
Quartz
Lamp
FRP34
(46 in. L)
FRS34
(46 in. L)
1
1
ACCESSORIES
CATALOG NO.
FWG22
FWG23
FWG24
FWG32
FWG33
FWG34
FRPATMB
FRSATMB
FRPWMB
FRSWMB
RVS2
RVS3
RVS4
UPC
6 85360 08406 0
6 85360 08407 7
6 85360 08408 4
6 85360 08409 1
6 85360 08410 7
6 85360 08411 4
6 85360 08402 2
6 85360 08404 6
6 85360 08403 9
6 85360 08405 3
6 85360 13765 0
6 85360 13766 7
6 85360 13767 4
DESCRIPTION
COMPATIBLE WITH
Wire Guard for 2-Element Heaters FRS2/FRP2 (24 in. L)
Wire Guard for 2-Element Heaters FRS2/FRP2 (33 in. L)
Wire Guard for 2-Element Heaters FRS2/FRP2 (46 in. L)
Wire Guard for 3-Element Heaters FRS3/FRP3 (24 in. L)
Wire Guard for 3-Element Heaters FRS3/FRP3 (33 in. L)
Wire Guard for 3-Element Heaters FRS3/FRP3 (46 in. L)
Adjustable Tilt Mounting Bracket - FRP Series
Adjustable Tilt Mounting Bracket - FRS Series
Wall Mounting Bracket - FRP Series
Wall Mounting Bracket - FRS Series
24 in. Red Vycor sleeve
FR(*)22/FR(*)32
33 in. Red Vycor sleeve
FR(*)23/FR(*)33
46 in. Red Vycor sleeve
FR(*)24/FR(*)34
CARTONS SHIP WT. (LBS)
1
1 (454)
1
1.5 (680)
1
2 (907)
1
1.5 (680)
1
2 (907)
1
2.5 (1134)
1 Set
1 (454)
1 Set
1 (454)
1 Set
6 (2722)
1 Set
6 (2722)
1
1
1
-
(1) One element per carton order. * Denotes remaining catalog number (See Enclosure Chart).
For the latest models and information, please visit our website at www.qmarkmep.com117
RADIANT HEATERS
SINGLE-ELEMENT INFRARED HEATER
HRK SERIES
STATUARY BRONZE
IDEAL SPACES | Car Washes; Parking Garages; Showrooms; Work Stations; Loading Docks; Aircraft Hangers; Warehouses
ENCLOSURE TYPE | Painted Steel
ELEMENT TYPE* | Quartz
REFLECTIVE ANGLE | 60° Symmetrical
•
Ideal for supplemental and spot heating
•
•
Heavy-duty gold anodized reflector has one of the
highest levels for radiating heat energy
Horizontal ceiling mount with supplied chains or to wall
using the optional FRPWMB wall mounting bracket
•
•
Optional HWG wire guard provides a protective safety
screen preventing objects contacting hot element
High quality finish and steel internal sheet metal
parts give excellent service under most operating
conditions, including coastal salt air and most
industrial atmospheres**
NOTE: *Quartz Lamp: used indoors and outdoors for snow melting and spot heating. **Finish not intended for direct salt spray exposure in marine applications or highly corrosive greenhouse, swimming pool,
chemical storage or industrial atmospheres. Maintain at least 5 ft. in radiant path, between bottom of heater and combustible material. Pigtail element leads for a more positive connection in high-traffic areas
where physical abuse.
MODELS & SPECIFICATIONS
CATALOG
NO.
UPC
VOLTS
WATTS
REFLECTIVE
ANGLE
HEIGHT
(IN)
WIDTH
(IN)
HRK41512
HRK42020
HRK42024
HRK42027
HRK42034
HRK42048
HRK42060
HRK53020
HRK53024
HRK53027
HRK53034
HRK53048
HRK53060
6 85360 08280 6
6 85360 08281 3
6 85360 08282 0
6 85360 08283 7
6 85360 08284 4
6 85360 08286 8
6 85360 08287 5
6 85360 08288 2
6 85360 08289 9
6 85360 08290 5
6 85360 08291 2
6 85360 08293 6
6 85360 08294 3
120
208
240
277
347
480
600
208
240
277
347
480
600
1500
2000
2000
2000
2000
2000
2000
3000
3000
3000
3000
3000
3000
60 Sym
60 Sym
60 Sym
60 Sym
60 Sym
60 Sym
60 Sym
60 Sym
60 Sym
60 Sym
60 Sym
60 Sym
60 Sym
3.375
3.375
3.375
3.375
3.375
3.375
3.375
3.375
3.375
3.375
3.375
3.375
3.375
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
SHIP
LENGTH
(IN)
46
46
46
46
46
46
46
57
57
57
57
57
57
SHIP
WT.
(LBS)
9
9
9
9
9
9
9
11
11
11
11
11
11
ACCESSORIES
UPC
DESCRIPTION
HWG46
6 85360 13837 4
Wire Guard
COMPATIBLE
WITH
JRK4
HWG57
6 85360 13838 1
Wire Guard
JRK5
CATALOG NO.
118
1
SHIP WT.
(LBS)
1
1
1.5
CARTONS
MOUNTING CLEARANCES
•
12 in. to vertical side walls
•
36 in. between heaters mounted
side by side. Heaters may be
mounted end to end
•
3 in. to ceiling
•
96 in. to floor
RADIANT HEATERS
PLUG-IN RADIANT HEATER
FRR SERIES
GOLD ANODIZED
ALUMINUM
IDEAL SPACES | Laundry Rooms; Work Shops; Toll Booths; Garages; Assembly Lines; Well Houses; Loading Docks
ENCLOSURE TYPE | Gold Anodized Aluminum
ELEMENT TYPE* | Quartz Tube
REFLECTIVE ANGLE | 60° Symmetrical
•
Ideal for supplemental and spot heating
•
Three-prong cord set for easy plug in
•
Specific models includes switches for multi-wattage
operation
NOTE: *Quartz Tube: used indoors and outdoors for snow melting and spot heating. Maintain at least 5 ft. in radiant path, between bottom of heater and combustible material. Pigtail element leads for a
more positive connection in high-traffic areas where physical abuse.
MODELS & SPECIFICATIONS
CATALOG NO.
FRR11012B
FRR22012
UPC
VOLTS
WATTS
REFLECTIVE ANGLE
HEIGHT (IN)
WIDTH (IN)
SHIP LENGTH (IN)
SHIP WT. (LBS)
6 85360 08790 0
6 85360 14784 0
120
120
1000/500*
2000/1000
60 Sym
60 Sym
4.65
3.375
5.75
19
16.75
34
8
22
NOTE: *FRR11012B has switches for 500 or 1000 watt operation. Color: Gold anodized aluminum enclosure.
For the latest models and information, please visit our website at www.qmarkmep.com
119
RADIANT HEATERS
PLUG-IN RADIANT HEATERS | CHRR SERIES
IDEAL SPACES | Work Stations; Work Shops; Toll Booths; Garages; Assembly Lines; Well Houses; Loading/Shipping Docks;
Quick Drying (With Optional Roll Around Cart)
ENCLOSURE TYPE | Statuary Bronze Painted Steel
ELEMENT TYPE* | Quartz Tube
REFLECTIVE ANGLE | 60° Symmetrical
•
Ideal for supplemental and spot heating
•
Three-prong cord set for easy plug in
•
Heavy-duty gold anodized reflector has one of the
highest levels for radiating heat energy
•
Unit includes switches for multi-wattage operation;
full or 50% operation
•
Versatility is doubled as unit can be mounted on
ceiling or on optional cart and rolled to any location
for maximum spot heating effect
NOTE: *Quartz Tube: used indoors and outdoors for snow melting and spot heating. Maintain at least 5 ft. in radiant path, between bottom of heater and combustible material. Pigtail element leads for a
more positive connection in high-traffic areas where physical abuse.
STATUARY BRONZE
CHRR41512 & CHRR3024
CHRR35724
MODELS & SPECIFICATIONS
CATALOG NO.
CHRR35724
CHRR41512
CHRR53024
UPC
6 85360 10602 1
6 85360 08236 3
6 85360 08237 0
VOLTS
240
120
240
WATTS
5700/2850
1500
3000
REFLECTIVE ANGLE
60 Sym
60 Sym
60 Sym
HEIGHT (IN)
3.375
3.375
3.375
WIDTH (IN)
19
5.5
5.5
ROLL-AROUND CART ACCESSORIES
MODELS & SPECIFICATIONS
CATALOG NO.
UPC
DESCRIPTION
COMPATIBLE WITH
SHIP WT. (LBS)
CHRRCART1
6 85360 14129 9
Roll Around Cart
CHRR22012
11
CHRRCART2
6 85360 14130 5
Roll Around Cart
CHRR35724
11
ITEMS BELOW DO NOT INCLUDE CART (Two wheeled cart supplied by others.)
120
CHRRCMK1
6 85360 14131 2
Flat Bracket Hardware
CHRR22012
3
CHRRCMK2
6 85360 14132 9
Formed Bracket Hardware
CHRR35724
3
SHIP LENGTH (IN)
34
46
57
SHIP WT. (LBS)
22
9
11
RADIANT HEATERS
INDUSTRIAL INFRARED HEATER
BRM SERIES
2.0 KW Fixed
STAINLESS STEEL
4.5 KW Fixed
6.0 KW Fixed
13.5 KW Fixed w/Grille
IDEAL SPACES | Wastewater Treatment Plants; Loading Docks; Foundries; Auto or Marine Repair Facilities; Walkways; Assembly Areas; Enclosed Smoking Areas; Indoor/Outdoor Storage Areas
ENCLOSURE TYPE | Stainless Steel
ELEMENT TYPE* | Metal Sheath
REFLECTIVE ANGLE | 90° Symmetrical
•
Ideal for permanent supplemental, spot heating where
dependence on air movement is impractical
•
Heavy-duty U-Bend element
•
High-watt density and industrial design provides
a durable source of heat
•
Electric heaters convert energy to heat at 100% efficiency
•
Optional safety grilles are available
•
Primarily for permanent mounting on the ceiling, but
may be used in any orientation
•
Heater has sealed wiring compartment that allows units
for washdown
NOTE: *Metal Sheathed: used indoors or outdoors in high-traffic areas. Maintain at least 5 ft. in radiant path, between bottom of heater and combustible material. Pigtail element leads for a more positive
connection in high-traffic areas where physical abuse.
MODELS & SPECIFICATIONS
CATALOG NO.
BRM2081
BRM2021
BRM2041
BRM2061
BRM4581
BRM4521
BRM4541
BRM4561
BRM6083
BRM6023
BRM6071
BRM6043
BRM6063
BRM13583
BRM13523
BRM13571
BRM13543
BRM13563
UPC
6 85360 14314 9
6 85360 14315 6
6 85360 14316 3
6 85360 14317 0
6 85360 14318 7
6 85360 14319 4
6 85360 14320 0
6 85360 14321 7
6 85360 14322 4
6 85360 14323 1
6 85360 14324 8
6 85360 14325 5
6 85360 14326 2
6 85360 14327 9
6 85360 14328 6
6 85360 14329 3
6 85360 14330 9
6 85360 14331 6
WATTS
2,000
4,500
6,000
13,500
VOLTS
208
240
480
600
208
240
480
600
208
240
277
480
600
208
240
277
480
600
PHASE
REFLECTIVE
ANGLE
ELEMENT
TYPE
SHIP WT. (LBS)
1
18
1
18
1 and 3
1 and 3
1
1 and 3
1 and 3
3
3
1
1 and 3
1 and 3
90° Symm
Metal Sheath
25
55
NOTE: See page 124 for infrared accessories. Ground Fault Detection: Ground fault detection equipment is designed to monitor for any gradual changes in the insulation level due to humidity or mechanical
damage as it develops, thus, de-energizing the load to prevent arcing type faults, preventing premature element failure and potential fire damage. As a safety precaution it is highly recommended that industrial
infrared heaters must be protected by ground fault detection. Failure to comply could result in a building fire or serious equipment damage.
For the latest models and information, please visit our website at www.qmarkmep.com
121
RADIANT HEATERS
INDUSTRIAL PERMANENT INFRARED HEATER
CRN SERIES
EXTRUDED
ALUMINUM
IDEAL SPACES | Wastewater Treatment Plants; Loading Docks; Foundries; Auto or Marine Repair Facilities; Walkways; Assembly Areas; Enclosed Smoking Areas; Indoor/Outdoor Storage Areas
ENCLOSURE TYPE | Extruded Aluminum
ELEMENT TYPE* | Metal Sheath
REFLECTIVE ANGLE | 90° Symmetrical
•
Ideal for permanent spot heating where dependence on
air movement is impractical
•
Highly polished aluminum reflector extends over the
assembly to provide a uniform heating pattern
•
High-watt density and industrial design provides a
durable source of heat
•
Heating element connects to a sealed, moisture-resistant
terminal enclosure allowing unit to be washed down
•
Optional safety grilles are available
NOTE: *Metal Sheathed: used indoors or outdoors in high-traffic areas. Maintain at least 5 ft. in radiant path, between bottom of heater and combustible material. Pigtail element leads for a more positive
connection in high-traffic areas where physical abuse.
MODELS & SPECIFICATIONS
CATALOG
NO.
CRN1011
CRN1081
CRN1021
CRN1511
CRN1581
CRN1521
CRN1571
CRN1531
CRN2001
CRN2021
CRN2071
CRN2031
CRN2501
CRN2521
CRN2571
CRN2531
UPC
6 85360 14340 8
6 85360 14341 5
6 85360 14342 2
6 85360 14343 9
6 85360 14344 6
6 85360 14345 3
6 85360 14346 0
6 85360 14347 7
6 85360 14348 4
6 85360 14349 1
6 85360 14350 7
6 85360 14351 4
6 85360 14352 1
6 85360 14353 8
6 85360 14354 5
6 85360 14355 2
NOTE: See page 124 for infrared accessories.
122
WATTS
1,000
1,500
2,000
2,500
VOLTS
120
208
240
120
208
240
277
347
208
240
277
347
208
240
277
347
PHASE
REFLECTIVE
ANGLE
ELEMENT
TYPE
SHIP WT.
(LBS)
1
90° Symm
Metal
Sheath
10
1
90° Symm
Metal
Sheath
15
1
90° Symm
Metal
Sheath
18
1
90° Symm
Metal
Sheath
20
Front
Side
Height
1kw
1.5KW
2.0KW
2.5KW
Width
10”
27”
36”
46”
53”
Depth
8”
RADIANT HEATERS
PORTABLE INFRARED HEATER|ARL SERIES
IDEAL SPACES | Loading Docks; Walkways; Assembly Areas; Enclosed Smoking Areas;
Repair Stations and Storage Areas; Work Stations
ENCLOSURE TYPE | Steel
ELEMENT TYPE* | Metal Sheath
REFLECTIVE ANGLE | 90° Symmetrical
•
Ideal for portable spot heating where dependence on air movement is impractical
•
Low-watt density, hairpin element
•
1500 watt 120V model has attached cord and two-prong plug
•
Sturdy base assembly provides tip-resistant design
MODELS & SPECIFICATIONS
CATALOG NO.
ARL1511*
ARL2081
ARL2021
ARL2071
ARL2041
ARL2061
ARL4581
ARL4521
ARL4571
ARL4541
ARL4561
UPC
6 85360 14360 6
6 85360 14361 3
6 85360 14362 0
6 85360 14363 7
6 85360 14364 4
6 85360 14365 1
6 85360 14366 8
6 85360 14367 5
6 85360 14368 2
6 85360 14369 9
6 85360 14370 5
WATTS
1500
2000
4500
VOLTS
120
208
240
277
480
600
208
240
277
480
600
PHASE
REFLECTIVE ANGLE
ELEMENT TYPE
SHIP WT. (LBS)
15
18
1
90º Symm
Metal Sheath
25
NOTE: *Hand carry model includes cord and standard two-prong grounding plug. See page 124 for infrared accessories.
ELECTRIC CONTROL PANELS
•
Factory-wired for efficient installations and include terminal
blocks, on/off selector switches, power ON pilot light, and a
24V or 120V control circuit
•
Panels are available for use in 208V, 240V, 277V, 480V and
600V systems, with amp loads up to 40, 50, 100, 200 and
300 amps (inductive load - see chart below for resistive load rating)
•
NEMA 1 enclosure, UL/cUL listed and labeled control panel
•
Control transformer with fused primary and secondary
MODELS & SPECIFICATIONS
CATALOG NO.
CP404801PT
CP404801CT
CP504801
CP1004801
CP2004801
CP3004801
UPC
6 85360 13893 0
6 85360 13892 3
6 85360 13900 5
6 85360 13880 0
6 85360 13884 8
6 85360 13888 6
DESCRIPTION
Percentage Timer Panel, (1) 3-Pole Contactor
Time Delay Controller, (1) 3-Pole Contactor
(1) 3-Pole Contactor Panel
(2) 3-Pole Contactor Panel
(4) 3-Pole Contactor Panel
(6) 3-Pole Contactor Panel
AMPS*
40A
40A
40A
100A
200A
300A
VOLTS
208-480V
208-480V
208-480V
208-480V
208-480V
208-480V
SUPPLY VOLTS
120V
120V
120V
120V
120V
120V
DIMENSIONS (IN)
14.5 H x 14.5 W x 7.5 D
14.5 H x 14.5 W x 7.5 D
14.5 H x 14.5 W x 7.5 D
14 H x 15 W x 7.75 D
31.5 H x 18.2 W x 10 D
36 H x 30 W x 7 D
SHIP WT. (LBS)
45
45
45
55
65
70
NOTE: *Amp rating inductive load. Line fusing supplied by installer. Percentage Timer Panel for Metal Sheath Heaters only. Contact factory for 24V control, 600V supply, and Nema 4 enclosures. Add 25%
to list price for stainless steel (NEMA 4x) rating.
For the latest models and information, please visit our website at www.qmarkmep.com
123
RADIANT HEATERS
INDUSTRIAL INFRARED HEATER|ACCESSORIES
CORD & PLUG KITS FOR INDUSTRIAL M/N/L SERIES HEATERS
CATALOG NO.
L2081B
L2021B
L2071B
L2041B
L2061B
M4581B
M4521B
M4541B
M4561B
M6083B
M6083B
M6023B
M6023B
M6071B
M6043B
M6043B
M6063B
M6063B
M13583B
M13523B
M13571B
M13543B
M13543B
M13563B
M13563B
kW
2
2
2
2
2
4.5
4.5
4.5
4.5
6
6
6
6
6
6
6
6
6
13.5
13.5
13.5
13.5
13.5
13.5
13.5
VOLTS
208
240
277
480
600
208
240
480
600
208
208
240
240
277
480
480
600
600
208
240
277
480
480
600
600
PHASE
1
1
1
1
1
1
1
1
1
1
3
1
3
1
1
3
1
3
3
3
1
1
3
1
3
AMPS
9.6
8.3
7.2
4.2
3.3
21.6
18.8
9.4
7.5
28.8
16.7
25.0
14.5
21.7
12.5
7.2
10.0
5.8
37.5
32.5
48.7
28.1
16.3
22.5
13.0
WIRE SIZE
14/3
14/3
14/3
14/3
14/3
12/3
12/3
14/3
14/3
6/3
6/4
6/3
6/4
6/3
6/3
6/4
6/3
6/4
6/4
6/4
6/3
6/3
6/4
6/3
6/4
POWER CORDS
CS25143
CS25143
CS25143
CS25143
CS25143
CS25123
CS25123
CS25143
CS25143
CS25063
CS25064
CS25063
CS25064
CS25063
CS25063
CS25064
CS25063
CS25064
CS25064
CS25064
CS25063
CS25063
CS25064
CS25063
CS25062
LOCKING
LPS25083
LPS25083
LPS25083
LPS25083
LPS25083
LPS25083
LPS25083
LPS25083
LPS25083
LPS25083
LPS25124
LPS25083
LPS25124
LPS25083
LPS25083
LPS25104
LPS25083
LPS25084
LPS25083
LPS25083
LPS25083
LPS25083
LPS25104
LPS25083
LPS25084
NON-LOCKING
NPS25650
NPS25650
NPS25650
NPS25650
NPS25650
NPS1550
NPS25650
NPS1550
NPS1550
NPS1550
-
BRM SAFETY GRILLES, HANGING KITS & ROLL-AROUND KITS
CATALOG NO.
BRMWG2
BRMWG45
BRMWG60
BRMWG135
BRMHK
BRM60
BRM135
UPC
6 85360 14332 3
6 85360 14333 0
6 85360 14334 7
6 85360 14335 4
6 85360 14336 1
6 85360 14338 5
6 85360 14339 2
CRN SAFETY GRILLES
CATALOG NO.
CRNWG01
CRNWG105
CRNWG200
CRNWG250
UPC
6 85360 14356 9
6 85360 14357 6
6 85360 14358 3
6 85360 14359 0
DESCRIPTION
Safety Grille Kit for BRM 2KW Heaters
Safety Grille Kit for BRM 4.5KW Heaters
Safety Grille Kit for BRM 6KW Heaters
Safety Grille Kit for BRM 13.5KW Heaters
Hanging Kit to mount BRM or CRN heaters, includes Chain and Hooks
Rollaround Cart Kit for 6.0KW BRM heaters (Includes Safety Grilles)
Rollaround Cart Kit for 13.5KW BRM heaters (Includes Safety Grilles)
SHIP WT. (LBS)
3
3
4
14
2
8
8
DESCRIPTION
Safety Grille Kit for CRN 1KW Heaters
Safety Grille Kit for CRN 1.5KW Heaters
Safety Grille Kit for CRN 2KW Heaters
Safety Grille Kit for CRN 2.5KW Heaters
SHIP WT. (LBS)
3
3
7
10
CONTROL ACCESSORIES FOR INDUSTRIAL INFRARED HEATER
CATALOG NO.
PDS60050
TOS240
TOS480
WMGF240
WMGF480
UPC
6 85360 15233 2
6 85360 15166 3
6 85360 15167 0
6 85360 15234 9
6 85360 15235 6
NOTE: *S = Stock AND NS = Non-Stock.
124
SHIP WT. (LBS)
18
18
18
18
18
18
18
18
18
25
25
25
25
25
26
26
26
26
55
55
55
55
55
55
55
DESCRIPTION
Power Disconnect Kit for Fixed or Portable (M Series)
Tip-Over Switch for Fixed or Portable (M Series) 240V only
Tip-Over Switch for Fixed or Portable (M Series) 480V only
Wall-Mounted Ground Fault Detection for 240V NEMA 4
Wall-Mounted Ground Fault Detection for 480V NEMA 4
kW MODELS
ALL
6 or 13.5
6 or 13.5
ALL
ALL
AVAILABILITY*
S
NS
NS
NS
NS
SHIP WT. (LBS)
8
15
15
17
17
PORTABLE HEATERS
125
PORTABLE HEATERS
PORTABLE RADIANT CONVECTION HEATER
WPC1500 SERIES
•
Ideal for supplemental heat precisely where it is needed
•
Multi-watt adjustable thermostat allows user to choose between
three wattage levels for greater comfort, control and energy
savings
•
Removable wheel kit allows unit to be safely wall-mounted near
electrical outlet
•
Positive off switch
•
Tip-over switch and linear limit for added safety
•
3-prong grounded cord set
•
Radiant heat heats objects and people, not the air
NEUTRAL
GRAY
IDEAL SPACES
Bedrooms; Living/Family Rooms; Bathrooms;
Basements; Offices; Conferences Rooms;
Waiting Rooms
MODELS & SPECIFICATIONS
CATALOG NO.
WPC1500
UPC
VOLTS
WATTS
AMPS
HEIGHT (IN)
WIDTH (IN)
DEPTH (IN)
SHIP WT. (LBS.)
6 85360 15132 8
120
1500/1000/500
12.5/8.3/4.2
18-1/8
29-11/16
3-1/8
27
RADIANT PLUG-IN UNDER DESK HEATER
202SL SERIES
•
Personalized warmth where and when it is needed
•
Mounting versatility with low-profile wall mount or floor stands
•
Lighted built-in on/off switch
•
3-prong power cord and plug included
•
Safe to the touch
•
Radiant heat heats objects and people, not the air
•
Energy efficient - costs 1-2 cents per hour to operate
NORTHERN
WHITE
IDEAL SPACES
Offices; Workstations; Conferences Rooms;
Bedrooms; Receptionist Areas
MODELS & SPECIFICATIONS
CATALOG NO.
202SLB
MC202SLR
APT2
UPC
VOLTS
WATTS
AMPS
0 98319 88965 2
Master Carton (6 pcs)
0 98319 88964
120
120
5
170
170
1.4
1.4
NOTE: *Shipping dimensions
126
HEIGHT (IN)
WIDTH (IN)
14-3/8
22-17/32
16-1/4*
27-1/8*
Portable Thermostat
DEPTH (IN)
SHIP WT. (LBS.)
1
13-1/2*
8
50
PORTABLE HEATERS
PORTABLE FAN-FORCED UTILITY HEATER
MMHD SERIES
•
Two heat settings for a full range of comfort
•
Automatic thermostat
•
Fan-only feature to circulate air during non-heating periods
•
Tip-over safety switch and thermal limit
•
Built-in carrying handle and guards
•
120V grounded cord and plug
NORTHERN
WHITE
IDEAL SPACES
Bedrooms; Living/Family Rooms; Basements;
Campers; Offices; Workshops; Garages;
Warehouses; Receptionist Areas
MODELS & SPECIFICATIONS
CATALOG NO.
MMHD1502T
UPC
VOLTS
WATTS
AMPS
BTU/HR
120
1500
12.5
5120
120
1300
10.8
4437
0 98319 86168 9
HEIGHT (IN)
WIDTH (IN)
DEPTH (IN)
SHIP WT. (LBS.)
14-1/8
10-1/8
6-3/4
9.2
PORTABLE FAN-FORCED/RADIANT UTILITY HEATER
MCM SERIES
•
Three heat settings: 600W radiant; 900W fan-forced;
1500W fan-forced and radiant
•
Automatic thermostat
•
Ceramic core element
•
Tip-over safety switch and thermal limit
•
Built-in carrying handle and guards
•
120V grounded cord and plug
NORTHERN
WHITE
IDEAL SPACES
Bedrooms; Living/Family Rooms; Basements;
Campers; Offices; Workshops; Garages;
Warehouses; Receptionist Areas
MODELS & SPECIFICATIONS
CATALOG NO.
MCM1503
UPC
0 98319 86166 5
VOLTS
120
WATTS
AMPS
BTU/HR
1500
12.5
5120
900
7.5
3072
600
5
2048
HEIGHT (IN)
WIDTH (IN)
DEPTH (IN)
SHIP WT. (LBS.)
14-1/2
9-3/4
7-1/2
9
For the latest models and information, please visit our website at www.qmarkmep.com
127
PORTABLE HEATERS
PORTABLE UNIT HEATER
QPH4A SERIES
•
Two heat settings: 9,100 BTUs (2,667 Watts),
13,650 BTUs (4,000 Watts)
•
Permanently lubricated, unit-bearing fan motor
•
Three-way bracket lets you position unit on floor or other flat
surface, or mount to ceiling or wall
•
Adjustable thermostat to maintain heating comfort levels
•
Compact and easy to carry with built-in handles
•
6 ft. cord included
CHARCOAL
GRAY
IDEAL SPACES
Garages; Workshops; Basements; Stairwells;
Lobbies; Warehouses
MODELS & SPECIFICATIONS
CATALOG NO.
QPH4A
UPC
0 98319 86114 6
VOLTS
WATTS
AMPS
208
Low: 2667/2000
240
High: 4000/3000
BTU/HR
12.5/8.3/4.2
HEIGHT (IN)
WIDTH (IN)
DEPTH (IN)
SHIP WT. (LBS.)
14
16
8
25
9102/9526
13,652/10,239
CONTRACTOR HEATER
BRH SERIES
•
Steel spiral fin brazed to metal sheathed element
for maximum heat output
•
Built-in thermostat
•
Safety high temperature limit
•
Industrial finger-proof, steel intake and discharge grilles
•
6 ft. heavy-duty cord
•
Built-in handle/cord storage
•
Permanently lubricated motor
RED
IDEAL SPACES
Garages; Workshops; Warehouses;
Construction Sites
MODELS & SPECIFICATIONS
CATALOG NO.
UPC
VOLTS
WATTS
AMPS
BTU/HR
HEIGHT (IN)
WIDTH (IN)
DEPTH (IN)
SHIP WT. (LBS.)
BRH402
0 98319 86200 6
240/208
4000/3000
16.7/14.1
13,650/10,238
11
10-1/2
9-5/8
17
BRH562*
0 98319 86202 0
240/208
5600/4200
23.3/20.2
19,110/14,333
12
11-3/8
10-3/4
19
NOTE: *Includes fan-only function. Plug type for BRH402 is 20 Amp, 240V NEMA #6-20P. Plug type for BRH562 is 30 Amp, 240V NEMA #6-30P.
128
PORTABLE HEATERS
PORTABLE ELECTRIC HEATER
PT268 SERIES
•
Adjustable, automatic thermostat
•
Safety tip-over switch
•
Safety overload switch with caution light
•
Heater automatically shuts off if unit overheats
•
Live power signal light
•
6 ft. heavy-duty cord
CHARCOAL
GRAY
IDEAL SPACES
Garages; Workshops; Warehouses;
Construction Sites
MODELS & SPECIFICATIONS
CATALOG NO.
PT268
UPC
VOLTS
WATTS
AMPS
BTU/HR
HEIGHT (IN)
WIDTH (IN)
DEPTH (IN)
SHIP WT. (LBS.)
6 85360 09646 9
240
4000
16.7
13,648
16-1/2
15-1/2
11-1/2
12
NOTE: Plug type for PT268 is 20 Amp, 240V NEMA #6-20P.
PORTABLE DIGITAL HYDRONIC HEATER|LFH SERIES
IDEAL SPACES
Bedrooms; Living/Family Rooms; Bathrooms;
Basements; Offices; Conferences Rooms;
Lobbies; Waiting Rooms
NEUTRAL GRAY
•
Maintains individual room temperature to provide heat
only in the places you want
•
•
Large element reservoir maximizes volume of heat
storage fluid for prolonged comfort
Gentle heat continues to radiate even after the
thermostat turns off due to the hydronic elements
retention qualities
•
•
High-impact Lexan® and steel unitized body resists
dents, scratches and rust
Tip-over switch prevents heater from operating
if knocked over
•
•
Proportional digital control with five heating levels
Electronic digital LCD display with backlight three-button control
•
Linear high-temperature safety cutout will
automatically shut off unit in event of air blockage
•
120V-ready for in-home use
MODELS & SPECIFICATIONS
CATALOG NO.
LFH1502P
UPC
VOLTS
WATTS
AMPS
BTU/HR
HEIGHT (IN)
LENGTH (IN)
DEPTH (IN)
SHIP WT. (LBS.)
6 85360 15126 7
120
200/1500
1.6/12.5
682/5118
9-5/16
51-1/2
3-45/64
27
For the latest models and information, please visit our website at www.qmarkmep.com
129
PORTABLE HEATERS
PORTABLE ELECTRIC HYDRONIC HEATER|FHP SERIES
IDEAL SPACES
Bedrooms; Living/Family Rooms; Bathrooms;
Basements; Offices; Conferences Rooms;
Lobbies; Waiting Rooms
NAVAJO WHITE
•
Maintains individual room temperature to provide heat
only in the places you want
thermostat turns off due to the hydronic elements
retention qualities
•
Large element reservoir maximizes volume of heat
storage fluid for prolonged comfort
•
Tip-over switch prevents heater from operating
if knocked over
•
High-impact Lexan® and steel unitized body resists
dents, scratches and rust
•
Heavy-duty welded steel louvered grilles discourage
insertion of foreign objects
•
Linear high-temperature safety cutout will
automatically shut off unit in event of air blockage
•
Automatic thermostat maintains desired comfort level;
120V-ready for in-home use
•
Gentle heat continues to radiate even after the
•
Tuck-Away carrying handle out of sight when not in use
MODELS & SPECIFICATIONS
CATALOG NO.
UPC
VOLTS
FHP0750T
6 85360 1610 2
120
FHP1500T
6 85360 1607 8
120
WATTS
AMPS
BTU/HR
750
6.3
2560
1500
12.5
5120
HEIGHT (IN)
8-27/64
LENGTH (IN)
34
58
DEPTH (IN)
SHIP WT. (LBS.)
12
5-31/32
19
PORTABLE ELECTRIC CONVECTOR HEATER|FBE SERIES
IDEAL SPACES
Bedrooms; Living/Family Rooms; Bathrooms;
Basements; Offices; Conferences Rooms;
Lobbies; Waiting Rooms
NORTHERN WHITE
•
Maintains individual room temperature to provide heat
only in the places you want
•
High-impact Lexan® and steel unitized body resists
dents, scratches and rust
•
Built-In thermostat for controlled comfort
•
Linear high-temperature safety cutout will
automatically shut off unit in event of air blockage
•
Dual wattage for maximum comfort
•
Tip-over switch prevents heater from operating
if knocked over
•
Convection heat minimizes air flow, reducing
flow of bacteria and dust
•
Chimney fin element designed for maximum air circulation
•
120V-ready for in-home use
MODELS & SPECIFICATIONS
CATALOG NO.
FBE15002
130
UPC
VOLTS
WATTS
AMPS
BTU/HR
HEIGHT (IN)
LENGTH (IN)
DEPTH (IN)
SHIP WT. (LBS.)
0 98319 86156 6
120
1000/1500
8.3/12.5
3413/5120
7-1/2
45
5-31/32
11
PORTABLE HEATERS
PORTABLE ELECTRIC HEATER
TBX MOBILE WARMING
™
•
High BTU per hour heater without the exhaust fumes
or moisture associated with gas heat
•
Heats lower to the floor for natural convection
•
Includes 8 ft. cord and NEMA 6-50P plug
•
Convenient storage area under lid for tools and accessories
•
Collapsible handle for easy transport and storage
•
Thermostat with positive OFF (40°- 100°F)
•
Fan-only mode for air recirculation, fume exhaust or fresh
air supply
•
Over temperature limit protects unit from low air flow
conditions
Factories; Stores; Warehouses; Greenhouses;
Stock Rooms; Flood Dry-Out Areas; Workshops;
Repair Stations; Building Construction; Drywall
Dry-Out; Tent Heating; Frozen Pipe Thaw-Out
•
Lower profile to prevent tipping
COLORS | Red
RED
IDEAL SPACES & APPLICATIONS
MODELS & SPECIFICATIONS
CATALOG NO.
TBX104
TBX754
UPC
KW
VOLTS
AMPS
BTU/HR
CFM
DIMENSIONS
SHIP WT (LBS.)
6 85360 15127 4
6 85360 15128 1
9.5
7.5
240
240
39.6
31.2
32,424
52,598
1100
1100
28.5” H x 25” W x 18.5” D
28.5” H x 25” W x 18.5” D
70
70
For the latest models and information, please visit our website at www.qmarkmep.com
131
PORTABLE HEATERS
HIGH-TEMP ELECTRIC BLOWER
MSDH SERIES
•
High BTU per hour heater without the exhaust fumes or moisture
associated with gas heat
•
Can be operated unattended without risk of fire or need for refueling
•
Fan-only mode for air recirculation, fume exhaust or fresh air supply
•
Dual thermostat operation. 120V control supply and transformer
with pilot light
•
Over temperature limit protects unit from low air flow conditions
•
Powder-coated, corrosion-resistant 20-gauge steel housing. 10 in.
pneumatic wheels and 4 in. locking caster. Inlet and outlet flexible
duct accessories available for ducting up to 165 ft.
•
Adjustable damper accessory controls outlet temperature; 1 HP
motor with adjustable pulleys allowing for adjustable fan speeds
•
Temperature high limit cutout for freeze protection, removing
fumes, speed drying or curing, insect control and more
MODELS & SPECIFICATIONS
CATALOG NO.
MSDH3043
MSDH3093
MSDH4843
MSDH4893
MSDH6043
MSDH6093
UPC
KW
6 85360 14913 4
6 85360 14914 1
6 85360 14917 2
6 85360 14918 9
6 85360 14921 9
6 85360 14922 6
30
30
48
48
60
60
ACCESSORIES
CATALOG NO.
MSDHFX20
MSDHDA20
MSDHSK20
MSDHDC
MSDHAD
132
UPC
6 85360 15072 7
6 85360 15076 5
6 85360 15074 1
6 85360 15078 9
6 85360 15080 2
VOLTS
(3-PHASE)
480
600
480
600
480
600
RED
IDEAL SPACES
Mining; Oil/Gas Extraction; Construction Sites;
Food Processing; Textile Mills; Paper Mills; Printing
Plants; Chemical Plants; Truck Docks; Marinas
COLORS
Red
AMPS
BTU/HR
37.2
30.0
58.9
47.3
73.3
58.9
102,236
102,236
163,776
163,776
204,720
204,720
TEMP RISE
DEG F
35-88
35-88
59-141
59-141
70-172
70-172
DIMENSIONS
20 in. Diameter Flexible Duct (25 feet)
20 in. Diameter Adaptor Ring
20 in. Diameter Splice Kit
20 in. Diameter Duct Clamp
Adjustable Damper
DIMENSIONS
44” L x 25.4” W x 38.5” H
44” L x 25.4” W x 38.5” H
44” L x 25.4” W x 38.5” H
44” L x 25.4” W x 38.5” H
44” L x 25.4” W x 38.5” H
44” L x 25.4” W x 38.5” H
SHIP WT.
(LBS)
150
150
160
170
170
170
SHIP WT. (LBS.)
45
20
40
3
12
PORTABLE HEATERS
PORTABLE ELECTRIC BLOWER
MEDH SERIES
•
Can be left unattended without threat of poisoning from
combustion by-products associated with fuel-fired heaters
•
Heavy-duty spiral fin tube metal sheath elements for uniform
heat output
•
Control comfort with built-in thermostat and safety
thermal cutout
•
Fan-only mode for air recirculation, fume exhaust or fresh
air supply
•
Single- and three-phase operation
•
10- in. pneumatic wheels
•
Thermostat selector switch
•
Optional ceiling/wall bracket available
•
Cord sets for power supply feed available
RED
IDEAL SPACES
Mining; Oil/Gas Extraction; Construction Sites;
Food Processing; Textile Mills; Paper Mills; Printing
Plants; Chemical Plants; Truck Docks; Marinas
COLORS
Red; Custom Colors Available
MODELS & SPECIFICATIONS
CATALOG NO.
UPC
KW
PHASES
VOLTS
AMPS
BTU/HR
MEDH1021CKA
MEDH1583A
MEDH1521A
MEDH1523A
MEDH1543A
MEDH3043A
6 85360 15258 5
6 85360 15225 7
6 85360 15219 6
6 85360 15221 9
6 85360 15223 3
6 85360 15227 1
10
15
15
15
15
30
1
3
1
3
3
3
240
208
240
240
480
480
41.7
41.8
62.5
36.3
18.6
36.3
34,120
51,180
51,180
51,180
51,180
102,360
TEMP RISE
DEG F
35-88
35-88
59-141
59-141
70-172
70-172
DIMENSIONS
40” H X 30” W X 24” D
40” H X 30” W X 24” D
40” H X 30” W X 24” D
40” H X 30” W X 24” D
40” H X 30” W X 24” D
40” H X 30” W X 24” D
SHIP WT.
(LBS)
65
65
65
65
65
75
STATUS
S
NS
NS
NS
S
NS
NOTE: MEDH1021CKA includes cord & plug kit packaged inside heater carton. Status descriptions: S - Stock; NS - Non-Stock.
ACCESSORIES
CATALOG NO.
DHCWM
SCS25043
SCS10063
SCS25064
SCS25124
UPC
6 85360 15212 7
6 85360 15251 6
6 85360 15250 9
6 85360 15252 3
6 85360 15253 0
CORD & PLUG KITS
CATALOG NO.
MEDH1021A
MEDH1583A
MEDH1521A
MEDH1523A
kW
10
15
15
15
VOLTS
240
208
240
240
MEDH1543A
15
480
MEDH3043A
30
480
PHASE
1
3
1
3
1
3
3
KW
4/3 SO
6/3 SO
6/4 SO
12/4 SO
AMPS
39.6
41.8
62.5
36.3
31.2
18.1
36.3
WIRE SIZE
6/3
6/4
4/3
6/4
6/4
12/4
6/4
DESCRIPTION
Ceiling and wall bracket can be used on all models
DH1521A
DH1021A (10ft long w/plug)
DH1583A, DH1523A, DH3043A
DH1543A
25 FT CORD SET
SCS10063 (10ft.)
SCS25064
SCS25043
SCS25064
SCS25064
SCS25124
SCS25064
LOCKING
LPS25064
LPS25064
LPS25064
LPS25104
-
NON-LOCKING
INCLUDED
NPS1550
NPS1550
-
SHIP WT. (LBS)
20
22
18
20
10
SHIP WT. (LBS)
18
20
22
20
20
10
20
NOTE: Models designated 1 and 3 phase can be field-wired for single-phase operation.
For the latest models and information, please visit our website at www.qmarkmep.com
133
AIR CURTAINS
135
AIR CURTAINS
INTRODUCTION|AIR CURTAIN APPLICATIONS
Air curtains are used for a wide variety of applications from thermal barriers
at shopping mall entrances, to fly and insect prevention at restaurant service
doors, to factory freight doors for wind resistance and temperature separation.
The air curtain enables traffic to flow unobstructed through openings while
maintaining separate environments, thus resulting in energy savings.
The most common type of air curtain is the horizontal, non-recirculating,
single jet type. It will satisfy the majority of needs for commercial and industrial
applications. The discharge velocity of the air curtain can range from 600 ft/
min, for entrance ways, to over 5,000 ft/min, for sealing environments from
wind effects and insects.
COMPATIBILITY CHART
WIND CONDITIONS CLASSIFICATIONS*
G=1-5 mph L=5-8 mph M=8-12 mph ST=12-15 mph SV=15-21 mph
DOOR HEIGHT
7 FT. RETAIL ENTRANCE
8 FT. INTERIOR
10 FT. INTERIOR
8 FT. EXTERIOR
10 FT. EXTERIOR
7 FT. CUSTOMER ENTRANCE
8 FT. CUSTOMER ENTRANCE
7 FT. SERVICE ENTRANCE
8 FT. SERVICE ENTRANCE
7 FT. COOLER
8 FT. COOLER
10 FT. COOLER
12 FT. COOLER
8 FT. FREEZER
10 FT. FREEZER
12 FT. FREEZER
8 FT. EXTERIOR
LOW
PROFILE
1/8 HP
ENVIRONMENTAL
SERIES
1/4 HP
1/2 HP
3/4 HP
DESCRIPTION & APPLICATION
Compact low-profile series designed for retail customer entrances, malls,
stores and restaurants. This air curtain acts as a thermal barrier for
mounting heights of 7 ft. customer entrances and 8 ft. interior doors.
G
G
L
G
M
L
ST
M
M
L
ST
M
Designed for supermarkets, schools, hospitals and other large
facilities. This air curtain acts as a thermal barrier or interior
separation device for mounting heights of 8-10 ft.
L
L
Designed for customer entrances (front door) and service
entrances (rear door). This air curtain acts as a thermal barrier or
fly and insect control device for mounting heights of 7-8 ft.
G
G
G
Designed for freezers, coolers, cold storage facilities,
processing plants and other refrigerated facilities.
This air curtain acts as a thermal barrier
for mounting heights of 7- 12 ft.
G
G
G
G
M
ST
10 FT. EXTERIOR
M
12 FT. INTERIOR OPENING
14 FT. INTERIOR OPENING
10 FT. EXTERIOR DOORWAY
12 FT. EXTERIOR DOORWAY
14 FT. EXTERIOR DOORWAY
L
NOTE: Wind conditions G = Gentle; L = Light; M = Moderate; ST = Strong; SV = Severe
136
HIGH VELOCITY
SERIES
1 HP 1-1/2 HP 3 HP
M
SV
ST
L
ST
L
SV
M
L
Designed for use in meat and poultry packing plants, processing
plants and food preparation areas. This air curtain acts as a fly
and insect control device for mounting heights of 8-10 ft.
Designed for warehouses, manufacturing plants and other
large facilities. This air curtain acts as a wind resistance or
interior separation device for mounting heights of 10-14 ft.
AIR CURTAINS
LOW PROFILE SERIES
AVAILABLE COLORS
Navajo Northern Charcoal
White
White
Gray
Statuary
Bronze
Desert
Tan
Gloss
Black
Neutral
Gray
Stainless
Steel
LOW-PROFILE
CONTEMPORARY SERIES
LOW-PROFILE
ARCHITECTURAL SERIES
IDEAL SPACES | Customer Entrances; Malls; Stores; Hospitals; Restaurants; Fast Food Windows; Schools; Walk-In Coolers
COLORS | Neutral Gray; Charcoal Gray; Stainless Steel; Navajo White; Northern White; Statuary Bronze; Desert Tan; Black
•
Modern contemporary design with choice of
electro-static powder paint or quality stainless steel
•
Quick-mount mounting plate included;
no template required to locate mounting screws
•
Patented design allows for continuous
side-by-side mounting
•
Extended anodized, aluminum design compliments
store interiors and public facilities
•
Cross-flow blower wheels for maximum outlet uniformity
•
•
Easily adjustable air directional vanes
Custom paint accents architectural sill-height heaters
in vestibules and receptions areas
•
Two-speed motor with convenient selector switch
•
Mounting heights of 7 ft. for exterior customer
entrances or 8 ft. interior doors
•
Pre-wired 48-in. molded cord/plug for simple installation
•
•
Reduce infiltration of exterior air, fumes, dust and dirt
Act as a temperature separation device, repelling
outside air while maintaining interior environment
MODELS & SPECIFICATIONS
ARCHITECTURAL
SERIES
CONTEMPORARY
STAINLESS STEEL
CONTEMPORARY
POWDER PAINT
CATALOG NO.
MLP36001115GR
MLP42001110GR
MLP48001108GR
MLP60001108GR
MLP36001208GR
MLP42001208GR
MLP48001206GR
MLP60001206GR
MLP36001115GRSS
MLP42001110GRSS
MLP48001108GRSS
MLP60001108GRSS
MLP36001208GRSS
MLP42001208GRSS
MLP48001206GRSS
MLP60001206GRSS
MLP36001115GA
MLP42001110GA
MLP48001108GA
MLP60001108GA
MLP36001208GA
MLP42001208GA
MLP48001206GA
MLP60001206GA
UPC
6 85360 14925 7
6 85360 14926 4
6 85360 14927 1
6 85360 14945 5
6 85360 14946 2
6 85360 14947 9
6 85360 14948 6
6 85360 14932 5
6 85360 14960 0
6 85360 14967 7
6 85360 14968 4
6 85360 14969 1
6 85360 14970 7
6 85360 14971 4
6 85360 14972 1
6 85360 14973 8
6 85360 14933 2
6 85360 14934 9
6 85360 14935 6
6 85360 14949 3
6 85360 14950 9
6 85360 14951 6
6 85360 14952 3
6 85360 14940 0
NOZZLE
WIDTH (IN)
36
42
48
60
36
42
48
60
36
42
48
60
36
42
48
60
36
42
48
60
36
42
48
60
VOLTS
AMPS
120
120
120
120
240
240
240
240
120
120
120
120
240
240
240
240
120
120
120
120
240
240
240
240
1.3
1.6
2.1
2.1
0.7
0.7
1.0
1.0
1.3
1.6
2.1
2.1
0.7
0.7
1.0
1.0
1.3
1.6
2.1
2.1
0.7
0.7
1.0
1.0
MAX VEL
(FPM)
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
For the latest models and information, please visit our website at www.qmarkmep.com
AVG VEL (FPM)
1800 / 1350
1800 / 1350
1800 / 1350
1800 / 1350
1800 / 1350
1800 / 1350
1800 / 1350
1800 / 1350
1800 / 1350
1800 / 1350
1800 / 1350
1800 / 1350
1800 / 1350
1800 / 1350
1800 / 1350
1800 / 1350
1800 / 1350
1800 / 1350
1800 / 1350
1800 / 1350
1800 / 1350
1800 / 1350
1800 / 1350
1800 / 1350
AIRFLOW
(CFM)
1200 / 900
1380 / 1040
1600 / 1210
2060 / 1550
1200 / 900
1380 / 1040
1600 / 1210
2060 / 1550
1200 / 900
1380 / 1040
1600 / 1210
2060 / 1550
1200 / 900
1380 / 1040
1600 / 1210
2060 / 1550
1200 / 900
1380 / 1040
1600 / 1210
2060 / 1550
1200 / 900
1380 / 1040
1600 / 1210
2060 / 1550
SHIP WT.
(LBS)
32
37
42
53
32
37
42
43
32
37
42
53
32
37
42
43
32
37
42
53
32
37
42
43
MOTORS (HP)
1/15
1/10
1/8
1/8
1/8
1/8
1/6
1/6
1/15
1/10
1/8
1/8
1/8
1/8
1/6
1/6
1/15
1/10
1/8
1/8
1/8
1/8
1/6
1/6
137
AIR CURTAINS
ENVIRONMENTAL SERIES
AVAILABLE COLORS
Navajo Northern Charcoal
White
White
Gray
Statuary
Bronze
Desert
Tan
Gloss
Black
Neutral
Gray
Stainless
Steel
IDEAL SPACES | Supermarkets; Schools; Hospitals; Restaurants; Bakeries; Cafeterias; Freezers; Processing Plants
COLORS | Neutral Gray; Charcoal Gray; Stainless Steel; Navajo White; Northern White; Statuary Bronze; Desert Tan; Black
138
•
Galvanized, corrosion-resistant, heavy-duty steel cabinet
•
Hot Water/Steam Heated Models available
•
Easy access; no tools required for inspection
and cleaning
•
•
Heavy-duty, completely enclosed motors with
permanently lubricated bearings
Exclusive Smart-Trac II Adjustable Mounting
System allows for 6-way adjustment
and alignment at cabinet to compensate for
possible overhead obstacles such as sprinkle
pipes, conduit and beams (optional on all models)
•
Electrically heated models available
AIR CURTAINS
MODELS & SPECIFICATIONS
WIDTH
(IN)
MAX VELOCITY
(FPM) HI/LOW*
E36001#25
E38001#25
E42001#25
E48001#25
E60002#25
E72002#25
E76002#25
E84002#25
E96002#25
E10803#25
E12003#25
E13203#25
E14403#25
36
38
42
48
60
72
76
84
96
108
120
132
144
2800 / 1850
2800 / 1850
2800 / 1850
2800 / 1850
2800 / 1850
2800 / 1850
2800 / 1850
2800 / 1850
2800 / 1850
2800 / 1850
2800 / 1850
2800 / 1850
2800 / 1850
E36001#50
E38001#50
E42001#50
E48001#50
E60002#50
E72002#50
E76002#50
E84002#50
E96002#50
E10803#50
E12003#50
E13203#50
E14403#50
36
38
42
48
60
72
76
84
96
108
120
132
144
3800 / 2815
3800 / 2815
3800 / 2815
3800 / 2815
3800 / 2815
3800 / 2815
3800 / 2815
3800 / 2815
3800 / 2815
3800 / 2815
3800 / 2815
3800 / 2815
3800 / 2815
E36001#75
E38001#75
E42001#75
E48001#75
E60001#75
E72002#75
E76002#75
E84002#75
E96002#75
E10803#75
E12003#75
E13203#75
E14403#75
36
38
42
48
60
72
76
84
96
108
120
132
144
4850 / 3590
4850 / 3590
4850 / 3590
4850 / 3590
4850 / 3590
4850 / 3590
4850 / 3590
4850 / 3590
4850 / 3590
4850 / 3590
4850 / 3590
4850 / 3590
4850 / 3590
CATALOG NO.
AVG VELOCITY (FPM) AVG AIR FLOW RATE
HI/LOW*
(CFM) HI/LOW*
1/4 HP MODELS
1620 / 1200
1670 / 1240
1795 / 1330
2000 / 1480
2880 / 2135
3240 / 2400
3340 / 2475
3620 / 2680
4000 / 2960
4860 / 3600
5240 / 3880
5620 / 4160
6000 / 4440
1/2 HP MODELS
3040 / 2250
2460 / 1820
2965 / 2195
2535 / 1880
2890 / 2140
2730 / 2020
2815 / 2085
3040 / 2250
3230 / 2390
4375 / 3240
3040 / 2250
4920 / 3645
2965 / 2195
5070 / 3755
2910 / 2155
5500 / 4070
2815 / 2085
6080 / 4500
3040 / 2250
7380 / 5465
2950 / 2184
7960 / 5890
2875 / 2130
8540 / 6320
2815 / 2085
9120 / 6750
3/4 HP MODELS
3880 / 2875
3140 / 2325
3790 / 2805
3240 / 2400
3685 / 2730
3480 / 2575
3595 / 2660
3880 / 2875
3395 / 2510
4580 / 3390
3880 / 2875
6280 / 4650
3790 / 2805
6480 / 4795
3715 / 2750
7020 / 5195
3595 / 2660
7760 / 5745
3880 / 2875
9420 / 6975
3765 / 2790
10160 / 7520
3670 / 2720
10900 / 8070
3595 / 2660
11640 / 8615
2000 / 1480
1955 / 1450
1900 / 1410
1855 / 1375
2125 / 1575
2000 / 1480
1955 / 1450
1915 / 1420
1855 / 1375
2000 / 1480
1945 / 1440
1895 / 1405
1855 / 1375
MOTORS
(QTY @ HP)
INPUT
POWER
RATING
1 PH (KW)**
INPUT
POWER
RATING
3 PH (KW)**
SHIP WT.
(LBS)
1 @ 1/4
1 @ 1/4
1 @ 1/4
1 @ 1/4
2 @ 1/4
2 @ 1/4
2 @ 1/4
2 @ 1/4
2 @ 1/4
3 @ 1/4
3 @ 1/4
3 @ 1/4
3 @ 1/4
0.41
0.41
0.41
0.41
0.82
0.82
0.82
0.82
0.82
1.23
1.23
1.23
1.23
0.24
0.24
0.24
0.24
0.48
0.48
0.48
0.48
0.48
0.72
0.72
0.72
0.72
65
67
70
77
128
130
134
142
154
195
207
219
231
1 @ 1/2
1 @ 1/2
1 @ 1/2
1 @ 1/2
2 @ 1/2
2 @ 1/2
2 @ 1/2
2 @ 1/2
2 @ 1/2
3 @ 1/2
3 @ 1/2
3 @ 1/2
3 @ 1/2
0.62
0.62
0.62
0.62
1.25
1.25
1.25
1.25
1.25
1.87
1.87
1.87
1.87
0.40
0.40
0.40
0.40
0.80
0.80
0.80
0.80
0.80
1.20
1.20
1.20
1.20
74
76
79
86
148
148
152
160
172
222
234
246
258
1 @ 3/4
1 @ 3/4
1 @ 3/4
1 @ 3/4
1 @ 3/4
2 @ 3/4
2 @ 3/4
2 @ 3/4
2 @ 3/4
3 @ 3/4
3 @ 3/4
3 @ 3/4
3 @ 3/4
0.94
0.94
0.94
0.94
1.87
1.87
1.87
1.87
1.87
2.81
2.81
2.81
2.81
1.20
1.20
1.20
1.20
2.39
2.39
2.39
2.39
2.39
3.59
3.59
3.59
3.59
83
86
89
96
112
166
172
179
192
249
262
275
288
NOTE: *Low speed only available on 1-Phase units. **AMP draw estimated as 1 PH = Power Rating x 1,000 / Volts and 3 PH = Power Rating x 1,000 / Volts x 1.732.
# Indicate Voltage: 1 = 120/1, 2 = 220/1, 3 = 208/3, 4 = 230/3, 5 = 460/3.
For the latest models and information, please visit our website at www.qmarkmep.com139
AIR CURTAINS
3-PHASE ENVIRONMENTAL
ELECTRICALLY HEATED
AVAILABLE COLORS
Navajo Northern Charcoal
White
White
Gray
Neutral
Gray
Statuary
Bronze
Desert
Tan
Gloss
Black
Stainless
Steel
IDEAL SPACES | Vestibules; Lobbies; Staging Areas; Reception Areas; Waiting Rooms
COLORS | Neutral Gray; Charcoal Gray; Stainless Steel; Navajo White; Northern White; Statuary Bronze; Desert Tan; Black
•
Heated units reduce the wind chill effect near entrances
•
•
New modular design allows 8 to 48 kW of heating
capacity, in lengths ranging from 36 to 144 in.
Air-flow safety sensor disables heating element in the
event motor/blowers need servicing or are wired incorrectly
•
•
Large, easily accessible pre-wired control box is side
mounted and features hinged swing-down access panel
Use wall-mounted 24V thermostat for temperature
control (not included)
•
•
Easily visible indicator lights on control panel alerts
operator when fan and heat are operating
•
Heating elements are thermally protected and include a
pilot light feature
Exclusive Smart-Trac II Adjustable Mounting
System allows for 6-way adjustment
and alignment at cabinet to compensate for
possible overhead obstacles such as sprinkle
pipes, conduit and beams (optional on all models)
MODELS & SPECIFICATIONS
CATALOG NO.
WIDTH
(IN)
NO. OF
CABINETS
CONTROL MAX VELOCITY
VOLTAGE
(FPM)
E36++1#50HE
E42++1#50HE
E48++1#50HE
E60++1#50HE
E72++2#50HE
E84++2#50HE
E96++2#50HE
E108++3#50HE
E120++3#50HE
E132++3#50HE
E144++3#50HE
36
42
48
60
72
84
96
108
120
132
144
1
1
1
1
2
2
2
3
3
3
3
24
24
24
24
24
24
24
24
24
24
24
E42++1#75HE
E48++1#75HE
E60++1#75HE
E72++2#75HE
E84++2#75HE
E96++2#75HE
E108++3#75HE
E120++3#75HE
E132++3#75HE
E144++3#75HE
42
48
60
72
84
96
108
120
132
144
1
1
1
2
2
2
3
3
3
3
24
24
24
24
24
24
24
24
24
24
AVG VELOCITY
(FPM)
1/2 HP MODELS
3800
3800
3800
3800
3800
3800
3800
3800
3800
3800
3800
3/4 HP MODELS
4850
4850
4850
4850
4850
4850
4850
4850
4850
4850
AVG AIR FLOW RATE
(CFM)
MOTORS
(QTY @ HP)
SHIP WT.
(LBS)
3040
2890
2815
2740
3040
2910
2815
3040
2950
2875
2815
2460
2730
3040
3350
4920
5460
6080
7380
7920
8540
9120
1 @ 1/2
1 @ 1/2
1 @ 1/2
1 @ 1/2
2 @ 1/2
2 @ 1/2
2 @ 1/2
3 @ 1/2
3 @ 1/2
3 @ 1/2
3 @ 1/2
93
98
105
117
177
181
189
261
273
285
297
3685
3595
3395
3880
3715
3595
3880
3765
3670
3595
3480
3880
4580
6280
6960
7760
9420
10100
10900
11640
1 @ 3/4
1 @ 3/4
1 @ 3/4
2 @ 3/4
2 @ 3/4
2 @ 3/4
3 @ 3/4
3 @ 3/4
3 @ 3/4
3 @ 3/4
108
115
131
195
208
221
288
301
314
327
++ (In model number) total heater kw available (select from above). # (In model number) select voltage: 3 = 208V 3-ph, 4 = 240V/208V 3-ph, 5 = 480V 3-ph. ** Multiply listed wattage by .75 For actual 208V
rating. Maximum 15 kW per cabinet at 240V.
CABINETS kw (BTU/HR) 1-Cabinet: 08 (27,230); 12 (40,980); 16 (54,640) / 2-Cabinet: 16 (54,640); 24 (81,960); 32 (109,280) / 3-Cabinet: 24 (81,960); 36 (122,940); 48 (163,920)
140
AIR CURTAINS
SINGLE-PHASE ENVIRONMENTAL
ELECTRICALLY HEATED
AVAILABLE COLORS
Navajo Northern Charcoal
White
White
Gray
Neutral
Gray
Statuary
Bronze
Desert
Tan
Gloss
Black
Stainless
Steel
IDEAL SPACES | Vestibules; Lobbies; Staging Areas; Reception Areas; Waiting Rooms
COLORS | Neutral Gray; Charcoal Gray; Stainless Steel; Navajo White; Northern White; Statuary Bronze; Desert Tan; Black
•
Heated units reduce the wind chill effect near entrances
•
Wall-mounted 24V thermostat for temperature control
•
Heated units supplied with pre-wired heater control
box for efficient installation
•
Multiple coil capacities for proper application requirements
•
Heater control panel mounts in front of nozzle, below grill
MODELS & SPECIFICATIONS
CATALOG NO.
WIDTH (IN)
E36061125H
WATTS
BTU/HR
CONTROL
VOLTAGE
MAX VEL
(FPM)
AVG VEL
(FPM)
AIRFLOW
(CFM)
SHIP WT.
(LBS)
MOTORS
(QTY @ HP)
2500
2000
1620
77
1 @ 1/4
36
E42061125H
42
E48061125H
48
E36091125H
36
E42091125H
42
E48091125H
48
6,000
9,000
20,478
30,717
24
24
2500
1900
1795
83
1 @ 1/4
2500
1855
2000
90
1 @ 1/4
2500
2000
1620
77
1 @ 1/4
2500
1900
1795
85
1 @ 1/4
2500
1855
2000
90
1 @ 1/4
24 IN. DRIVE-THRU WINDOW UNIT
AVAILABLE COLORS
Navajo Northern Charcoal
White
White
Gray
Neutral
Gray
Statuary
Bronze
Desert
Tan
Gloss
Black
Stainless
Steel
IDEAL SPACES | Restaurant Drive-Thru Windows; Drive-Ins; Schools
COLORS | Neutral Gray; Charcoal Gray; Stainless Steel; Navajo White; Northern White; Statuary Bronze; Desert Tan; Black
•
Designed to provide protection against flies and insects,
dust and odors
MODELS & SPECIFICATIONS
CATALOG NO.
DESCRIPTION
E24001115F
E24001115G
E24001115FG
With filter only
With intake grille only
With filter and grille
MAX FPM
AT NOZZLE
3000
3000
3000
•
MAX CFM
AT NOZZLE
1600
1600
1600
For service windows up to 30 in. wide with a maximum
mounting height of 5 ft. nozzle-to-counter
MAX FPM 2’
ABOVE COUNTER
750
750
750
For the latest models and information, please visit our website at www.qmarkmep.com
HP
VOLTS
1/15
1/15
1/15
120
120
120
MAX AMPS SHIP WT. (LBS.)
1.3
1.3
1.3
25
25
25
141
AIR CURTAINS
ENVIRONMENTAL HOT WATER / STEAM-HEATED
AVAILABLE COLORS
Navajo Northern Charcoal
White
White
Gray
Neutral
Gray
Statuary
Bronze
Desert
Tan
Gloss
Black
Stainless
Steel
IDEAL SPACES | Facilities with continuously open doors that require perimeter heating
COLORS | Neutral Gray; Charcoal Gray; Stainless Steel; Navajo White; Northern White; Statuary Bronze; Desert Tan; Black
•
Provides an economical source of heat when steam or
hot water is readily available
•
Premium quality coils provide superior heat transfer
for both low-pressure steam and hot water applications
•
Treats incoming air and prevents cold air from infiltrating
large areas
•
Universal left- or right-hand opposite end
connected coils
•
Also used as supplemental heat when operated with
door closed to provide additional perimeter heating
•
Single- or double-row coils available for desired capacity
•
Unique universal construction method designed for both
low-pressure steam and hot water applications
•
Constructed of highly-effective 1/2-in. copper tubing
with corrugated aluminum fins
MODELS & SPECIFICATIONS
HOT WATER
Based on 70°F entering air, 200°F entering water & 180° exiting water
ONE ROW
TWO ROW
WIDTH
(IN)
CATALOG NO.
CAPACITY
(MBH)
TEMP RISE
(F)
CAPACITY
(MBH)
48
60
72
84
96
108
120
132
144
E48001#50HW@
E60002#50HW@
E72002#50HW@
E84002#50HW@
E96002#50HW@
E10803#50HW@
E12003#50HW@
E13203#50HW@
E14403#50HW@
54.1
77.4
91.8
106
121
134
159
173
188
16.3
16.2
17.1
17.6
18.2
16.6
18.3
18.5
18.9
104
149
176
203
231
267
304
331
359
48
60
72
84
96
108
120
132
144
E48001#75HW@
E60002#75HW@
E72002#75HW@
E84002#75HW@
E96002#75HW@
E10803#75HW@
E12003#75HW@
E13203#75HW@
E14403#75HW@
63.2
93.3
107
123
142
163
187
203
221
14.9
15.3
15.6
16.0
16.7
15.8
16.8
17.0
17.4
122
180
207
239
272
315
359
391
424
TEMP RISE
(F)
1/2 HP MODELS
31.2
31.1
32.7
33.7
34.7
33.0
35.0
35.4
36.1
3/4 HP MODELS
28.7
29.6
30.1
31.1
32.1
30.5
31.5
32.7
32.5
STEAM
Based on 5 psig steam, 70°F entering air
ONE ROW
TWO ROW
CATALOG NO.
CAPACITY
(MBH)
TEMP RISE
(F)
CAPACITY
(MBH)
TEMP RISE
(F)
E48001#50HS@
E60002#50HS@
E72002#50HS@
E84002#50HS@
E96002#50HS@
E10803#50HS@
E12003#50HS@
E13203#50HS@
E14403#50HS@
81.6
111
128
145
164
186
210
226
244
24.7
23.4
24.1
24.1
24.8
23.0
24.3
24.2
24.7
-
-
E48001#75HS@
E60002#75HS@
E72002#75HS@
E84002#75HS@
E96002#75HS@
E10803#75HS@
E12003#75HS@
E13203#75HS@
E14403#75HS@
94.2
131
148
168
189
215
242
261
282
22.4
21.7
21.7
21.8
22.4
20.8
21.9
21.9
22.3
180
251
283
321
360
410
462
499
538
42.7
41.5
41.5
41.7
42.8
39.8
41.9
41.8
42.6
NOTE: # - Indicate Voltage: 1 = 120/1, 2 = 200/1, 3 = /208/3, 4 = 230/3, 5 = 460/3; @ denote no. of coil rows; ALL - Add 12 in. to length listed for total unit width. Hot Water/Steam units require 6 week lead time.
142
AIR CURTAINS
HIGH-VELOCITY SERIES
AVAILABLE COLORS
Navajo Northern Charcoal
White
White
Gray
Neutral
Gray
Statuary
Bronze
Desert
Tan
Gloss
Black
Stainless
Steel
IDEAL SPACES | Warehouses; Manufacturing Plants; Large Facilities
COLORS | Neutral Gray; Charcoal Gray; Stainless Steel; Navajo White; Northern White; Statuary Bronze; Desert Tan; Black
•
Galvanized, corrosion-resistant cabinet and intake grill
•
Corrosion-resistant dual-intake scrolls
•
Precision-balance twin stainless steel blower wheels
•
Exclusive Smart-Trac II Adjustable Mounting
System allows for 6-way adjustment
and alignment at cabinet to compensate for
possible overhead obstacles such as sprinkle
pipes, conduit and beams (optional on all models)
3 HP MODELS
1-1/2 HP MODELS
1 HP MODELS
MODELS & SPECIFICATIONS
CATALOG NO.
WIDTH (IN)
MAX VELOCITY
(FPM)
AVG VELOCITY
(FPM)
AVG AIR FLOW
RATE (CFM)
MOTORS
(QTY @ HP)
INPUT POWER
RATING 3 PH (KW)*
SHIP WT.
(LBS.)
EL36001#00LI
EL38001#00LI
EL42001#00LI
EL48001#00LI
EL60001#00LI
EL72002#00LI
EL76002#00LI
EL84002#00LI
EL96002#00LI
EL10803#00LI
EL12003#00LI
EL13203#00LI
EL14403#00LI
EL36001#05LI
EL38001#05LI
EL42001#05LI
EL48001#05LI
EL60001#05LI
EL72002#05LI
EL76002#05LI
EL84002#05LI
EL96002#05LI
EL10803#05LI
EL12003#05LI
EL13203#05LI
EL14403#05LI
EL36001#30LI
EL38001#30LI
EL42001#30LI
EL48001#30LI
EL60001#30LI
EL72002#30LI
EL76002#30LI
EL84002#30LI
EL96002#30LI
EL10803#30LI
EL12003#30LI
EL13203#30LI
EL14403#30LI
36
38
42
48
60
72
76
84
96
108
120
132
144
36
38
42
48
60
72
76
84
96
108
120
132
144
36
38
42
48
60
72
76
84
96
108
120
132
144
5250
5250
5250
5250
5250
5250
5250
5250
5250
5250
5250
5250
5250
5900
5900
5900
5900
5900
5900
5900
5900
5900
5900
5900
5900
5900
7200
7200
7200
7200
7200
7200
7200
7200
7200
7200
7200
7200
7200
4200
4095
3990
3890
3675
4200
4095
4025
3890
4200
4075
3975
3890
4130
4015
3895
3780
3540
4130
4015
3930
3780
4130
3990
3875
3780
5040
4905
4760
4615
4320
5040
4905
4795
4615
5040
4870
4730
4615
3400
3500
3770
4200
4960
6800
7000
7600
8400
10,200
11,000
11,800
6000 / 4440
3345
3430
3680
4080
4780
6690
6860
7425
8160
10,035
10,770
11,505
12,240
4080
4190
4495
4980
5830
8160
8380
9060
9960
12,240
13,140
14,040
14,940
1@1
1@1
1@1
1@1
1@1
2@1
2@1
2@1
2@1
3@1
3@1
3@1
3@1
1 @ 1 1/2
1 @ 1 1/2
1 @ 1 1/2
1 @ 1 1/2
1 @ 1 1/2
2 @ 1 1/2
2 @ 1 1/2
2 @ 1 1/2
2 @ 1 1/2
3 @ 1 1/2
3 @ 1 1/2
3 @ 1 1/2
3 @ 1 1/2
1@3
1@3
1@3
1@3
1@3
2@3
2@3
2@3
2@3
3@3
3@3
3@3
3@3
1.20
1.20
1.20
1.20
2.39
2.39
2.39
2.39
2.39
3.59
3.59
3.59
3.59
3.19
3.19
3.19
3.19
6.37
6.37
6.37
6.37
6.37
9.56
9.56
9.56
9.56
1.51
1.51
1.51
1.51
3.03
3.03
3.03
3.03
3.03
4.54
4.54
4.54
4.54
65
67
70
77
128
130
134
142
154
195
207
219
231
80
82
88
92
108
160
164
172
184
240
252
264
276
91
94
98
106
122
182
188
197
212
273
288
303
318
NOTE: # - Indicate Voltage: 3 = 208/3, 4 = 230/3, 5 = 460/3, 6 = 600/3
*AMP Draw maybe Estimated as Follows: 1-ph = Power Rating * 1,000 / Volts ; 3-phase = Power Rating * 1,000 / Volts * 1.732
For the latest models and information, please visit our website at www.qmarkmep.com
143
AIR CURTAINS
3-PHASE HIGH-VELOCITY
ELECTRICALLY HEATED
AVAILABLE COLORS
Navajo Northern Charcoal
White
White
Gray
Neutral
Gray
Statuary
Bronze
Desert
Tan
Gloss
Black
Stainless
Steel
IDEAL SPACES | Warehouses; Manufacturing Plants; Large Facilities
COLORS | Neutral Gray; Charcoal Gray; Stainless Steel; Navajo White; Northern White; Statuary Bronze; Desert Tan; Black
•
New modular designed cabinet allows 8 to 48 kW of
heating capacity, in lengths ranging from 42 to 144 inches
•
Air-flow safety sensor disables heating element in the
event motor/blowers need servicing or are wired incorrectly
•
Large, easily accessible pre-wired control box is
side-mounted; features hinged swing-down access panel
•
Use wall-mounted 24V thermostat for temperature
control (not included)
•
Easily visible indicator lights on control panel alerts
operator when fan and heat are operating
•
•
Helical coil heating element modules are easily replaceable
•
Heating elements are thermally protected and include a
pilot light feature
Exclusive Smart-Trac II Adjustable Mounting
System allows for 6-way adjustment
and alignment at cabinet to compensate for
possible overhead obstacles such as sprinkle
pipes, conduit and beams (optional on all models)
•
Fan-only feature for winter and summer operation
MODELS & SPECIFICATIONS
WIDTH (IN)
# OF
CABINETS
CONTROL
VOLTAGE
E42++1#00HE
E48++1#00HE
E60++1#00HE
E72++2#00HE
E84++2#00HE
E96++2#00HE
E108++3#00HE
E120++3#00HE
E132++3#00HE
E144++3#00HE
42
48
60
72
84
96
108
120
132
144
1
1
1
2
2
2
3
3
3
3
24
24
24
24
24
24
24
24
24
24
E42++1#30HE
E48++1#30HE
E60++1#30HE
E72++2#30HE
E84++2#30HE
E96++2#30HE
E108++3#30HE
E120++3#30HE
E132++3#30HE
E144++3#30HE
42
48
60
72
84
96
108
120
132
144
1
1
1
2
2
2
3
3
3
3
24
24
24
24
24
24
24
24
24
24
CATALOG NO.
MAX VEL
(FPM)
AVG VEL (FPM)
AIRFLOW
(CFM)
# MOTORS @ HP
SHIP WT.
(LBS.)
3990
3890
3675
4200
3990
3890
4200
4075
3975
3890
3770
4200
4960
6800
7540
8400
10200
10940
11800
12600
1@1
1@1
1@1
2@1
2@1
2@1
3@1
3@1
3@1
3@1
109
116
132
197
210
268
291
304
317
330
4760
4615
4320
5040
4760
4615
5040
4870
4730
4615
4495
4980
5830
8160
8990
9960
12240
13070
14040
14940
1@3
1@3
1@3
2@3
2@3
2@3
3@3
3@3
3@3
3@3
117
125
141
211
226
241
312
327
342
357
1 HP MODELS
5250
5250
5250
5250
5250
5250
5250
5250
5250
5250
3 HP MODELS
7200
7200
7200
7200
7200
7200
7200
7200
7200
7200
++ Total heater kW available (select from above) # - Select voltage: 3 = 208V 3-ph, 4 = 240V/208V 3-ph, 5 = 480V 3-ph ** Multiply listed wattage by .75 For actual 208v rating. Maximum 15 kW per cabinet at 240V.
CABINETS kw (BTU/HR) 1-Cabinet: 08 (27,230); 12 (40,980); 16 (54,640) / 2-Cabinet: 16 (54,640); 24 (81,960); 32 (109,280) / 3-Cabinet: 24 (81,960); 36 (122,940); 48 (163,920)
144
AIR CURTAINS
HIGH-VELOCITY|HOT WATER / STEAM-HEATED
AVAILABLE COLORS
Navajo Northern Charcoal
White
White
Gray
Neutral
Gray
Statuary
Bronze
Desert
Tan
Gloss
Black
Stainless
Steel
IDEAL SPACES | Facilities with continuously open doors that require perimeter heating
COLORS | Neutral Gray; Charcoal Gray; Stainless Steel; Navajo White; Northern White; Statuary Bronze; Desert Tan; Black
•
Provides an economical source of heat when steam or
hot water is readily available
•
Premium quality coils provide superior heat transfer
for both low-pressure steam and hot water applications
•
Also used as supplemental heat when operated with
door closed to provide additional perimeter heating
•
Universal left- or right-hand opposite end connected coils
•
Unique universal construction method designed for both
low-pressure steam and hot water applications
•
Single- or double-row coils available for desired capacity
•
Constructed of highly-effective 1/2-in. copper tubing
with corrugated aluminum fins
MODELS & SPECIFICATIONS
HOT WATER
Based on 70°F entering air, 200°F entering water & 180° exiting water
ONE ROW
TWO ROW
WIDTH
(IN)
CATALOG NO.
CAPACITY
(MBH)
TEMP RISE
(F)
CAPACITY
(MBH)
48
60
72
84
96
108
120
132
144
EL48001#00HW@
EL60001#00HW@
EL72002#00HW@
EL84002#00HW@
EL96002#00HW@
EL10803#00HW@
EL12003#00HW@
EL13203#00HW@
EL14403#00HW@
66.4
98.1
113
129
149
172
196
213
232
14.5
14.9
15.2
15.5
16.2
15.4
16.3
16.5
16.9
128
190
217
251
287
332
378
412
447
48
60
72
84
96
108
120
132
144
EL48001#05HW@
EL60001#05HW@
EL72002#05HW@
EL84002#05HW@
EL96002#05HW@
EL10803#05HW@
EL12003#05HW@
EL13203#05HW@
EL14403#05HW@
65.2
97.6
112
128
146
169
194
210
228
14.6
14.9
15.3
15.8
16.4
15.4
16.5
16.7
17.1
126
188
215
247
281
326
373
405
439
48
60
72
84
96
108
120
132
144
EL48001#30HW@
EL60001#30HW@
EL72002#30HW@
EL84002#30HW@
EL96002#30HW@
EL10803#30HW@
EL12003#30HW@
EL13203#30HW@
EL14403#30HW@
73.6
110
126
143
162
188
219
238
259
13.5
13.8
14.1
14.4
15.4
14.0
15.3
15.5
15.8
143
214
244
278
314
368
424
461
500
TEMP RISE
(F)
1/2 HP MODELS
27.9
28.7
29.3
30.2
31.2
29.7
31.5
31.9
32.5
3/4 HP MODELS
28.2
28.8
29.4
30.4
31.5
29.7
31.7
32.2
32.8
3/4 HP MODELS
26.2
26.8
27.4
28.0
29.7
27.5
29.6
30.0
30.6
STEAM
Based on 5 psig steam, 70°F entering air
ONE ROW
TWO ROW
CATALOG NO.
CAPACITY TEMP RISE
(MBH)
(F)
CAPACITY
(MBH)
TEMP RISE
(F)
EL48001#00HS@
EL60001#00HS@
EL72002#00HS@
EL84002#00HS@
EL96002#00HS@
EL10803#00HS@
EL12003#00HS@
EL13203#00HS@
EL14403#00HS@
98.5
137
154
175
197
224
252
272
294
21.6
20.9
20.9
21.0
21.6
20.0
21.2
21.1
21.5
189
263
296
336
378
430
484
523
564
41.4
40.2
40.1
40.4
41.4
38.5
40.6
40.5
41.2
E48001#75HS@
E60002#75HS@
E72002#75HS@
E84002#75HS@
E96002#75HS@
E10803#75HS@
E12003#75HS@
E13203#75HS@
E14403#75HS@
96.9
136
153
173
194
221
249
269
290
21.9
21
21.1
21.2
21.9
20.1
21.4
21.3
21.8
185
262
293
331
371
424
478
515
554
41.9
40.3
40.4
40.7
41.9
38.6
41.4
40.9
41.8
EL48001#30HS@
EL60001#30HS@
EL72002#30HS@
EL84002#30HS@
EL96002#30HS@
EL10803#30HS@
EL12003#30HS@
EL13203#30HS@
EL14403#30HS@
108
152
170
191
213
245
278
300
323
20
19.2
19.2
19.2
20.3
18.3
19.5
19.5
19.9
208
293
328
368
409
471
535
577
621
38.5
37
37.1
37.1
39
35.2
37.5
37.6
38.3
NOTE: # - Indicate Voltage: 3 = 208/3, 4 = 230/3, 5 = 460/3, 6 = 600/3; @ denote no. of coil rows; ALL - Add 12 in. to length listed for total unit width.
Hot Water/Steam units require 6 week lead time. Standard coils are opposite ends connected. For pricing on same end connected coils, consult factory.
For the latest models and information, please visit our website at www.qmarkmep.com
145
AIR CURTAINS
ACCESSORIES & CONTROLS|AIR CURTAINS
CONTROL PANELS
For three-phase air curtains requiring instant on/off automatic switches. Control Panels contain a single
contactor with one adjustable overload relay per motor, control transformer with fused primary and
secondary to meet NEC requirements, hands-off-auto selector switch and terminal strip for power wiring
and remote door switch.
CATALOG NO.
APCP101
APCP201
APCP301
APCP401
STYLE
1
2
3
4
SHIP WT. (LBS)
20
20
20
20
DOOR SWITCHES
For use with all air curtains for instant activation or deactivation of unit upon door opening or closing.
•
Automatic switches available for all models. (Three-phase motors require control panel.)
•
Plunger Style for hinged doors or Roller Style for sliding and track doors.
CATALOG NO.
C1200R
DESCRIPTION
Plunger/Roller
VOLTS
120
MAX AMPS
20
SHIP WT. (LBS)
1
NOTE: Not recommended for use with heated units.
LIGHT-DUTY BRACKET
For wall mounting of
Environmental Series.
12”
12”
24”
12”
CATALOG NO.
ACWBL
MEDIUM-DUTY BRACKET
SET OF
2
SHIP WT. (LBS)
10
SMART TRAC II
ADJUSTABLE MOUNTING SYSTEM
CATALOG NO.
ACWBM2
ACWBM3
For mounting of Environmental
Series up to 12-inches
from wall. Smart-Trac II
recommended.
SET OF
2
3
SHIP WT. (LBS)
52
78
FILTERS
S= Mounts on interior behind grille.
L= Exterior in place of grille.
APF2400S
APF2400L
•
•
For use with suspension rod or wall
mount applications.
This unique mounting system is now
available for Environmental and High
Velocity Series air curtains.
CATALOG NO.
ACSMTRK72
ACSMTRK84
ACSMTRK96
ACSMTRK108
ACSMTRK120
ACSMTRK132
ACSMTRK144
146
SIZE
(IN)
72
84
96
108
120
132
144
SHIP WT.
(LBS)
50
50
60
65
70
75
80
CLPF3600L
CLPF4800L
CLPF6000L
APF3600S
APF3800S
APF4200S
APF4800S
APF6000S
APF3600L
APF3800L
APF4200L
APF4800L
APF6000L
24”
44”
• For certain applications, such as food service or
sanitation, filtering the air curtains intake may be
desirable.
• Washable aluminum mesh filters for Low-Profile
and Environmental Series air curtains.
CATALOG NO.
HEAVY-DUTY BRACKET
SIZE
SHIP WT. (LBS)
24” DRIVE-THRU
24”
1
24
1
LOW PROFILE
36”
1
48”
1
60”
1
ENVIRONMENTAL
36”
2
38”
2
42”
2
48”
3
60”
4
36”
2
38”
2
42”
2
48”
3
60”
4
CATALOG NO.
HVWB2
HVWB3
For mounting of High
Velocity and High Volume
Series over roll-up
doors. Smart-Trac II
recommended.
SET OF
2
3
SHIP WT. (LBS)
72
98
GRILLES
• Optional anodized aluminum
architectural grille for Environmental
and Low-Profile Series air curtains.
ENVIRONMENTAL
CATALOG NO.
API036A
API048A
API060A
SIZE
36”
48”
60”
SHIP WT. (LBS.)
5
6
7
TAMPER-RESISTANT KIT
• For use in schools, hospitals, correctional
facilities or other locations prone to
vandalism.
• Prevents unauthorized access to air curtain.
• Complete tool and hardware package
provided.
CATALOG NO.
ACTRK
SIZE
36”
SHIP WT. (LBS)
2
CEILING FANS
For the latest models and information, please visit our website at www.qmarkmep.com147
147
CEILING FANS
DESTRATIFICATION CEILING FANS|1,600-3,025 SF
•
•
•
•
•
Area of coverage between 1600 - 3025 SF
Proprietary contoured-shaped blade design for achieving desired RPM and velocity
Patented* metal rolled back degrees comply with UL507 standard
Durable construction for continuous commercial use with same
manufacturing criteria as our heavy duty industrial line
Supplied with 8 in. and 24 in. downrods and secondary mounting cable
36201- 36" Commercial Fan
•
Ideally suited for small or isolated areas and as supplemental cooling fan
48201- 48" Commercial Fan
•
Designed for commercial facilities; provides maximum area coverage for both
summer cooling and winter heat destratification
56001LC - 56" Commercial / School Classroom Fan
•
Designed for spacious areas with lower ceilings where larger blade diameter
span creates maximum air velocity and area coverage at lower RPMs
CATALOG NO.
36201
48201
56001LC
Buildings; Factories; Gymnasiums;
High Bay Storage Facilities
NOTE: *US Patent # 5645403
MODELS & SPECIFICATIONS
BLADE SIZE (IN)
36
48
56
IDEAL SPACES | Industrial
VOLTS
120
120
120
MAX CFM*
12,500
21,000
25,500
AREA COVERAGE**
1,600 SF
2,025 SF
3,025 SF
SHIP WT. (LBS)
20
22
24
NOTE: *Effective amount of air volume moved past a plane 20ft. from fan. All specifications subject to change and improvement. **Area coverage rated for heat destratification at 20 ft. blade mounting height.
Maximum continuous operation ambient temperature 105°F.
DESTRATIFICATION CEILING FANS|3,800-5,000 SF
•
Area of coverage is between 3800-5000 SF
•
Mounting heights at 10 ft. or higher
•
Proprietary contoured shaped wide blade design for achieving desired
RPM and velocity
•
Powerful heavy duty motor capable of heat destratification at 45-75 ft. high
•
Supplied with 8 in. and 24 in. downrods and secondary mounting cable
•
Patented 56 in. reversible fan provides the identical airflow volume in either
forward or reverse rotation. The dual pitch blade is the only blade designed for
maximum reverse direction. Ideal for exhausting, condensation removal and
prevention, reverse destratification and other draft-free applications
IDEAL SPACES | Industrial
Buildings; Factories; Gymnasiums;
High Bay Storage Facilities
MODELS & SPECIFICATIONS
BLADE SIZE (IN)
56
56
56
60
60
60
56
CATALOG NO.
56001
56011†
56007
60001
60002
60011
56301RDP***
VOLTS
120
120
277
120
220
120
120
MAX CFM*
27,500
27,500
26,000
46,000
46000
46,000
27,000
AREA COVERAGE**
3,800 SF
3,800 SF
3,800 SF
5,000 SF
5,000 SF
5,000 SF
3,800 SF
SHIP WT. (LBS)
24
24
24
30
30
30
24
NOTE: † Model comes in brown. *Effective amount of air volume moved past a plane 20ft. from fan. All specifications subject to change and improvement. **Area coverage rated for heat destratification at 20
ft. blade mounting height. Maximum continuous operation ambient temperature 105°F. ***Reversible fan includes remote mounted toggle switch suitable for up to 12 fans. Switch requires pulling 4 wires (not
including ground) from fan to switch. Supplied with 24 in. downrods. Secondary mounting cable supplied. Straight-edge blades - minimum 10ft. above floor. Rolled-edge blades - minimum 7-10 ft. above floor.
148
CEILING FANS
SPECIALTY CEILING FANS
HARSH ENVIRONMENT SPRAY-PROOF
IDEAL SPACES | F ood Processing Plants; Wet Factory Locations; Indoor Swimming Pool Areas; Exposed Shipping Areas;
Outdoor Restaurants; Exposed Shipping Areas; Outdoor Malls
BLADE SIZE (IN)
56***
60
CATALOG NO.
56101
60101
VOLTS
120
120
MAX CFM*
25,500
41,000
AREA COVERAGE**
3,025 SF
5,000 SF
SHIP WT. (LBS)
23
24
NOTE: Supplied with 12 in. downrod.
AGRICULTURAL
IDEAL SPACES | Poultry Houses; Hog Sheds; Dairy Barns; Greenhouses; Nurseries; Stables
BLADE SIZE (IN)
56***
60
CATALOG NO.
56111
60111
VOLTS
120
120
MAX CFM*
25,500
41,000
AREA COVERAGE**
3,025 SF
5,000 SF
SHIP WT. (LBS)
23
24
NOTE: Supplied with 12 in. downrod.
3-SPEED PULL CHAIN
IDEAL SPACES | S pot cooling in areas where wall switches are not desired; production areas where single unit
designation operation is required
BLADE SIZE (IN)
48***
56***
CATALOG NO.
48203
56003
VOLTS
120
120
MAX CFM*
27,500
27,500
AREA COVERAGE**
3,800 SF
3,025 SF
SHIP WT. (LBS)
23
24
NOTE: Supplied with 8 and 24 in. downrods.
THEATER FAN
IDEAL SPACES | E ntertainment Establishments; Restaurants; Retail Where Black Color Of Ceiling Fans
Has To Match Interior Design
BLADE SIZE (IN)
48***
56
CATALOG NO.
48201B
56001B
VOLTS
120
120
MAX CFM*
21,000
27,500
AREA COVERAGE**
2,025 sq ft
3,800 sq ft
SHIP WT. (LBS)
23
24
NOTE: Secondary mounting cable supplied..
NOTE: Supplied with 12 in. downrod. *Effective amount of air volume moved past a plane 20ft. from fan, industry test. All specifications subject to change and improvement. **Area coverage rated for heat
destratification at 20 ft. blade mounting height. *** Maximum continuous operation ambient temperature 105°F.
For the latest models and information, please visit our website at www.qmarkmep.com149
CEILING FANS
ACCESSORIES
CATALOG
NO.
28001
28002
9FP024
9D12BW
9D18BW
9D36BW
9D48BW
99992
9DKIT
DESCRIPTION
SHIP WT.
(LBS)
FAN GUARD 62” DIAMETER FOR INDUSTRIAL 56” AND 60” FANS
FAN GUARD 52” DIAMETER FOR COMMERCIAL 36” AND 48” FANS ONLY
WHITE TILTED CANOPY COVER - BROWN(9FP023), BLACK( 9FP023B)
DOWNRODS - 12” Also available in brown, replace “W” in model number with “B”
DOWNRODS - 18” Also available in brown, replace “W” in model number with “B”
DOWNRODS - 36” Also available in brown, replace “W” in model number with “B”
DOWNRODS - 48” (FOR LONGER SIZES - CONSULT FACTORY)
OUTDOOR LOCATION INSTALLATION KIT*
DOWNROD Extension kit
50
40
1
1
1
3
4
1
2
OPTIONAL MOTOR
SPEED CONTROLS
CATALOG NO.
Ceiling Fan Guard
For gymnasiums and public facilities
NOTE: *Only for use with harsh environment ceiling
fans. Custom models available. Consult with factory for
information and specifications. Use only with heavy-duty/
industrial models - Not recommended for low ceiling
applications. Fan Guards ship via UPS
MODEL FAN AND QUANTITY PER CONTROL
VOLTS
AMPS
36201
12003
12006
12008
12012
27708*
120
120
120
120
277
3
6
8
12
8
3
7
10
12
-
12001N
12005N
120
120
1
5
-
48201
56101
56002
56007
2
2
5
5
6
6
10
10
NOISELESS MECHANICAL CONTROL
1
2
2
60001
60101
6
1
3
4
8
-
-
Controls 48” & 56” Models Only
Controls 48” & 56” Models Only
NOTE: *6 fans on 277V.
DESTRATIFICATION CEILING FANS
HEAT-DROPPER® CONCEPT
HEATINGAS
BILLS
CUT HEATING & COOLING BILLS BYREDUCE
AS MUCH
30%*
®
WINTER
Recovers wasted heat by eliminating heat stratification. Trapped warm air at the ceiling
caused by natural heat rise and poor air circulation is equalized by the movement of
the massive blade span. Thus ceiling to floor temperature is equalized. With a heat cost
savings of 30%, the LEADING EDGE fan system can pay for itself in one year. The
elimination of cold spots increases employee productivity and comfort.
SUMMER
73°
90°
(Winter)
(Winter)
themostat
58°
themostat
(Winter)
71°
(Winter)
Before
After
General air recirculation in non air-conditioned buildings creates a cooling breeze and
a “Wind Chill Factor” providing evaporation cooling of the skin surface dropping skin
temperature by 6°. The LEADING EDGE fan system supplements air-conditioned buildings by allowing the thermostat settings to be 8° higher. You’ll feel the
coolness of 72° with the thermostat set on 80° - an incomparable energy savings. Additional advantages, eliminates mold and mildew caused by stagnant air,
perfect for high humidity areas. No other fan has our higher air velocity capabilities. Small fans do not develop sufficient CFM to be effective in warm weather.
LEADING EDGE treats ceiling fans as a system, not as single unit – our fans provide larger area of coverage than
competition; therefore require fewer fans to perform the same function. Furthermore, the heavy duty design allows
considerable savings to maintenance or replacement costs. Substantial savings are realized on the total installed
costs of the system on a per square foot basis, which can be calculated via the following formula to the right. An
extreme example would be the use of discount store or home center promotional $49.95 fans. Let’s assume
these imported 56 in. curved tipped patio fans could overcome the AT buoyancy factor and could cover 900 ft.2
per fan. The result is that 65 fans would have to be installed and no summertime cooling would be achieved. The
low priced fan with its hidden additional costs is no bargain. Residential patio fans are commonly rated at 400 ft.2
per fan (20x 20 living room with an 8 ft. ceiling).
* Based on an ASHRAE “Saving Heating Costs in Warehouses” study.
150
Total area coverage:
_____ft2 (A)
Area coverage per fan:
_____ft2 (B)
Total fan units required: A/B=
______ (C)
Fan unit cost:
$ ______ (D)
Installation cost:
$ ______ (E)
Total installed cost: (C*D)+E
$___________
THERMOSTATS & CONTROLS
151
THERMOSTATS & CONTROLS
LOW
VOLT 6
COMMERCIAL/
INDUSTRIAL
MECHANICAL MANUAL TEMPERATURE CONTROL
o
o
o
o
-
-
-
o
-
-
-
TH106A
o
o
o
o
-
-
-
o
-
-
-
TH114A240DBA
o
o
o
o
-
-
-
o
-
-
-
-
-
-
-
-
-
TH522D1003
OTHER RADIANT
TH108PLUSA
FRS
-
FRP
-
CP
-
RCC
o
/ Contact MEP
CONVECTORS 8
QCH 7
-
/
o
o
/
/
/
/
o
o
/
/
/
o
/
o
o
/
/
/
o
/
o
o
/
/
/
/
/
/
MSPH
EFF 7
-
CU900
CDF 7
-
IUH 8
QTS 6
o
MUH 8
QFG
o
SED
GFR
COS-E 4
CWHDS 3
o
LFK 2
o
CWH 2
CBD
TL8230A1003/U
AWH 2
HBB
- See Model Selection Chart
QMKS 1
CWHDSAG 3
o Compatible
2500 1
ELECTRONIC W/
DIGITAL DISPLAY
COMPATIBILITY CHART
o
o
/
MS26
o
o
o
o
-
-
-
o
-
-
-
/
/
/
o
o
/
/
/
MD26
o
o
o
o
-
-
-
o
-
-
-
/
/
/
o
o
/
/
/
M601W
o
o
o
o
-
-
-
o
-
-
-
/
/
o
/
o
o
/
/
/
M601TPW
o
o
o
o
-
-
-
o
-
-
-
/
/
o
/
o
o
/
/
/
M602W
o
o
o
o
-
-
-
o
-
-
-
/
/
o
/
o
o
/
/
/
M602TPW
o
o
o
o
-
-
-
o
-
-
-
/
/
o
/
o
o
/
/
/
M611W
o
o
o
o
-
-
-
o
-
-
-
/
/
o
/
o
o
/
/
/
M612W
o
o
o
o
-
-
-
o
-
-
-
/
/
o
/
o
o
/
/
/
T100
o
o
o
o
-
-
-
o
-
-
-
/
/
o
/
o
o
/
/
/
T200
o
o
o
o
-
-
-
o
-
-
-
/
/
o
/
o
o
/
/
/
WR651
o
o
o
o
-
-
-
o
-
-
-
/
/
/
o
o
/
/
/
WR661
o
o
o
o
-
-
-
o
-
-
-
/
/
/
o
o
/
/
/
o
o
o
/
/
o
/
o
/
/
/
/
/
o
/
o
/
/
/
/
/
o
/
o
/
/
/
/
/
/
/
/
/
/
/
M600S*
M600MTP*
WT11A
WT12A
WR80
o
o
o
o
o
o
o
WR80EP
o
/
T8775A1009
o
o
o
o
o
T8775C1005
o
o
o
o
o
o
o
o
o
o
o
o
ELECTRONIC
RELAY
LTR1120
LTR208240
LTR1277
LTR2240
LT186F01
o
o
o
o
o
o
o
NOTE: (1) Electronic thermostats have amperage minimums and each model has different voltage requirements, please check catalog thermostat specifications. (2) AWH, CWH, AND LFK Series models require
the removal of the internal thermostat and wire wall thermostat in its place for proper fan operation. See model selection for specific thermostat. (3) CWHDSAG and CWHDS Series models require the removal
of the internal thermostat from unit. Wire wall thermostat for proper fan operation. See model selection for specific thermostats. (4) CRA Series models require the removal of the internal thermostat from unit.
Wire wall thermostat for proper fan operation. See model selection for specific thermostats. (5) Low voltage thermostats operate in conjunction with low voltage control systems using relays. Compatible with all
standard 24V two wire thermostats. Can accept analog signal of 0-10 VDC. (6) The 1100 watt units can use either single-pole or double-pole thermostats. The 1500 watt units must use a double-pole thermostat.
(three conductors from thermostat to unit). Does not apply to low voltage thermostats, which need a transformer. (7) CDF and EFF Series models require different thermostats based on internal wiring. Wire wall
thermostat for proper fan operation. See model selection for specific thermostats. Can not use digital thermostats with this unit. (8) Due to the complexity of wiring variations for remote wall thermostats with these
products, we recommend that you contact Technical Services for assistance.
152
THERMOSTATS & CONTROLS
MODEL SELECTION CHART
HEATER
THERMOSTAT
HEATER
THERMOSTAT
GFR1500F
TH106A, M601W, M611W, T100, WR651
CDF548
MS26, M601W
GFR2004F
TL8230A1003/U, TH106A, TH108PLUSA,
M602W, M612W, T200, WR661
CDF542
MS26, M601W
MS26, M601W
GFR2404F
TL8230A1003/U, TH106A, TH108PLUSA,
M602W, M612W, T200, WR661
CDF547
CDF558
MS26, M601W
GFR1500T2F
TH106A, M601W, M611W, T100, WR651
CDF552
MS26, M601W
GFR2004T2F
TL8230A1003/U, TH106A, TH108PLUSA,
M602W, M612W, T200, WR661
CDF557
MS26, M601W
EFF1500
MS26, M601W
MS26, M601W
GFR2404T2F
TL8230A1003/U, TH106A, TH108PLUSA,
M602W, M612W, T200, WR661
EFF3007
QFG1512IFM
TH106A, M601W, M611W, T100, WR651
EFF4008
MS26, M601W
MS26, M601W
QFG2024IFM
TL8230A1003/U, TH106A, TH108PLUSA,
M602W, M612W, T200, WR661
EFF4004
EFF4007
MS26, M601W
EFF4804
MS26, M601W
EFF4807
MS26, M601W
M602W, M612W, T200, WR661
EFF3003
-
QFG1512T2M
TH106A, M601W, M611W, T100, WR651
EFF3006
-
QFG2024T2M
TL8230A1003/U, TH106A, TH108PLUSA,
M602W, M612W, T200, WR661
EFF4003
-
EFF4006
-
QFG2224T2M
TL8230A1003/U, TH106A, TH108PLUSA,
M602W, M612W, T200, WR661
EFF4803
-
ECP1024
TL8230A1003/U, TH106A, TH108PLUSA,
M602W, M612W, T200, WR661
EFF4806
EFF48483
-
QFG2224IFM
QFG2228IF
TL8230A1003/U, TH106A, TH108PLUSA,
M602W, M612W, T200, WR661
ECP1524
TL8230A1003/U, TH106A, TH108PLUSA,
M602W, M612W, T200, WR661
EFF48483LV
QCH1101F
M601W, MS26
CZ1512T
TH106A, M601W, M611W, T100, WR651
QCH1151F
M601W, MS26
CZ1012T
TH106A, M601W, M611W, T100, WR651
QCH1202F
M601W, MS26
CZ1048T
TH106A, M601W, M611W, T100, WR651
QCH1207F
M601W, MS26
CZ1548T
TH106A M601W, M611W, T100, WR651
CZ2048T
TH106A, M601W, M611W, T100, WR651
CZ1512IF
TH106A, M601W, M611W, T100, WR651
CZ1012IF
TL8230A1003/U, TH106A, TH108PLUSA,
M602W, M612W, T200, WR661
CZ1048IF
TL8230A1003/U, TH106A, TH108PLUSA,
M602W, M612W, T200, WR661
CZ1548IF
TL8230A1003/U, TH106A, TH108PLUSA,
M602W, M612W, T200, WR661
CZ2048IF
TL8230A1003/U, TH106A, TH108PLUSA,
M602W, M612W, T200, WR661
NOTE: Programmable thermostats cannot be used with the models listed above.
For the latest models and information, please visit our website at www.qmarkmep.com153
THERMOSTATS & CONTROLS
THERMOSTATS|ELECTRONIC DIGITAL LINE VOLTAGE
ACTION
TYPE
WATT RATING
120V
208V
240V
277V
PILOT DUTY
TEMP. RANGE (ºF)
DIFFERENTIAL
FEATURES
TH108PLUSA
TH114A240DBA
TH106A
TL8230A1003/U
YTL9160AR1000OW
Triac: Silent Operation
12.5A Resistive
2-wire SPST
Minimum: 2-amp load
n/a
n/a
3000 watts
n/a
No
40ºF to 85ºF
Accuracy:
Within +/- 0.27ºF
Electronic Switch
15 A Resistive
4-wire DPST
No minimum load
n/a
n/a
3600 watts
n/a
No
40ºF to 85ºF
Accuracy:
Within 1ºF of setpoint
Triac: Silent Operation
Microprocessor
16.7A Resistive 2-wire SPST
16.7 A Resistive 4-wire DPST
Minimum: 2-amp load
2000 watts
n/a
4000 watts
n/a
No
40ºF to 85ºF
Accuracy:
Within +/- 0.27ºF
No minimum load
n/a
3120 watts
3600 watts
n/a
No
40ºF to 85ºF
Accuracy:
Within 1ºF of setpoint
Microprocessor
12.5A Resistive
2-wire SPST
Minimum: 0.4-amp load
1500 watts
2600 watts
3000 watts
n/a
No
40ºF to 85ºF
Accuracy:
Within +/- 1ºF
Digital, non-programmable
12.5amp model delivers
exceptional accuracy.
Ideal for radiant ceiling panels
and baseboard.
Not for fan-forced heaters.
Digital, non-programmable
model delivers exceptional
accuracy. Ideal for
radiant ceiling panels
and baseboard. Can be
used for fan-forced heaters.
Digital, programmable high
capacity model delivers
exceptional accuracy. Ideal
for radiant ceiling panels and
baseboard. Can be used for fanforced heaters and resistive loads.
Digital, programmable model
delivers exceptional accuracy.
Ideal for radiant ceiling panels
and baseboard. Can be used
for fan-forced heaters.
Wireless, digital and
programmable model delivers
exceptional accuracy. Ideal
for radiant ceiling panels and
baseboard. Can be used
for fan-forced heaters.
THERMOSTATS|ELECTRONIC DIGITAL LOW VOLTAGE
ACTION
TYPE
WATT RATING
120V
208V
240V
277V
PILOT DUTY
TEMP. RANGE (ºF)
DIFFERENTIAL
FEATURES
154
T8775A1009
T8775C1005
TH5220D1003
Electronic Switch
24V .015 -1.0A @ 30V 2-wire
n/a
n/a
n/a
n/a
24VAC
40ºF to 90ºF
Accuracy: Within 1ºF of setpoint
Electronic Switch
24V .015 -1.0A @ 30V 2-wire
n/a
n/a
n/a
n/a
24VAC
40ºF to 90ºF
Accuracy: Within 1ºF of setpoint
Electronic Switch
24V .015 -1.0A @ 30V 5-wire
n/a
n/a
n/a
n/a
24VAC
40ºF to 90ºF
Accuracy: Within 1ºF of set
Digital, non-programmable
24V “Round” model delivers exceptional
accuracy.
(Heat Only)
Digital, non-programmable
24V “Round” model delivers exceptional accuracy.
(Heat and Cool)
Digital, 24V programmable 2-stage 5-7
wire heat and cool thermostat. One-touch
temperature control with exceptional accuracy.
Ideal for plenum heaters, and HVAC systems.
THERMOSTATS & CONTROLS
THERMOSTATS|LINE VOLTAGE
ACTION
TYPE
WATT RATING
120V
208V
240V
277V
PILOT DUTY
TEMP. RANGE (ºF)
DIFFERENTIAL
FEATURES
ACTION
TYPE
WATT RATING
120V
208V
240V
277V
PILOT DUTY
TEMP. RANGE (ºF)
DIFFERENTIAL
FEATURES
MS26
MD26
Snap Action
SPST
DPST
Model MD26 has Positive OFF
22A
22A
22A
18A
No
50ºF to 80ºF
+/- 5ºF
M601W
M602W
Snap Action
SPST
DPST
Model M602W has Positive OFF
22A
22A
22A
18A
Yes 125VA
45ºF to 75ºF
+/- 4ºF
M601TPW
M602TPW
Snap Action
SPST
DPST
Model M602TPW has Positive OFF
22A
22A
22A
18A
Yes 125VA
45ºF to 75ºF
+/- 4ºF
M612W
M611W
Snap Action
DPST
SPST
Model M612W has Positive OFF
22A
22A
22A
18A
Yes 125VA
45ºF to 75ºF
+/- 2 1/2ºF
These economy thermostats
are the snap action type that
are used in apartment construction.
Good thermostat for its value.
Ideal for radiant cove heaters
and baseboard.
These bi-metal snap-action
thermostats are sensitive.
Large knob allow for
easy adjustment.
Same as M601W and M602W
except the cover mounting
cover offer tamper-proof feature.
Built-in heat anticipator
assures closer control of
room temperature.
M600MTP
M600S
T100
T200
WR651
Modulation (2-stage)
DPST
Simultaneous switching (double ckt)
Snap Action with Heat Anticipator
SPST
DPST
Creep (Hydraulic) Action
DPST
SPST
22A
22A
22A
18A
Yes 125VA
50ºF to 80ºF
22A
22A
22A
18A
Yes 125VA
50ºF to 80ºF
22A
22A
22A
18A
Yes 125VA
50ºF to 90ºF
22A
22A
22A
na
No
40ºF to 85ºF
Accuracy: Within 3ºF of setpoint
Accuracy: Within 3ºF of setpoint
+/- 2 1/2ºF
+/- 2ºF
One thermostat controls two separate
heating circuits and reduces input during
light load periods. Second stage activates
when temperature drops to approx.
1-1/2ºF below the first stage turn-ON
temperature.
Simultaneous control of two heating loads.
Used where the total load slightly exceeds
capacity of a single switch, where two
thermostats are impractical. Both switches
are calibrated to operate at approx. the
same temperature.
Line voltage thermostat with everything;
Performance, reliability, durability, and
a large knob. Built-in heat anticipation
assures close temperature regulation.
Large knob for easy rotation.
Extra-sensitive element in control
knob senses radiant heat as well
as air temperature for ultimate
control. May cause slight radio or
television interference in outlying
fringe areas.
WR661
For the latest models and information, please visit our website at www.qmarkmep.com155
THERMOSTATS & CONTROLS
CONTROLS|SPECIALTY
ACTION
TYPE
WATT RATING
120V
208V
240V
277V
PILOT DUTY
TEMP. RANGE (ºF)
DIFFERENTIAL
FEATURES
ACTION
TYPE
WATT RATING
120V
208V
240V
277V
PILOT DUTY
TEMP. RANGE (ºF)
DIFFERENTIAL
FEATURES
156
WR80
Snap Action Switch
SPST
JC80EP
Snap Action Switch
SPST
WT11A
WT12A
Positive snap action switch
SPDT
Nema 4X rated
25A
n/a
25A
25A
22A
Yes 125VA
40ºF to 110ºF
+/- 2 1/2ºF
25A
22A
22A
18A
Yes 125VA
40ºF to 90ºF
+/- 3ºF
25A
22A
22A
18A
Yes 125VA
40ºF to 90ºF
+/- 3ºF
Rugged design for garages, factories,
warehouses and similar commercial
and industrial installations. The WR80
can control several heaters by using an
external contractor.
This explosion proof room
thermostat is suitable for
Class 1, Group D and Class
II, Groups E, F, and G
locations.
Nema 4X weatherproof enclosure. The control
has a SPDT output and can be used for
heating or cooling (ventilation) Multi-positional
mounting offers flexibility in new or existing
installations.
LTR2240
TC1
Dual Silent Relay
(2) single pole switches
Resistive Inductive
N/A
25A 1HP, 8.8A
25A 1HP, 8A
N/A
Yes 125VA
Can be operate in 20 to 140ºF
Accuracy: Within 1.5ºF of setpoint
Enclosure protection for thermostats.
This dual level temperature relay may be
used to operate two separate heating loads by means of
a single low voltage thermostat.
Relay is mounted in an enclosure.
Material: Impact resistant polycarbonate. Clear.
Dimensions are: 7” L X 4.28” H X 2.75” D
LTR SERIES
Electronic Relays
Microprocessor base design
These electronic relays have been designed
for silent control of high voltage resistive loads
from a low voltage control circuit. Inductive
motor loads can also be controlled (120V to
240V only). Compatible with 24V thermostats.
LTR1120 - 120V; 22A
LTR208240 - 208V/240V; 22A
LTR1277 - 277V; 19A
The relays can be used with model LT186F01
electronic room sensor, providing proportional
and integral control. Also can be tied to
building management systems.
M600THW
M600THB
M600THW -White thermostat cover
with built-in thermometer.
For M600 Series stats.
M600THB - Beige thermostat cover
with built-in thermometer.
For M600 Series stats.
Thermostat enclosure kits are designed to
protect the thermostat. Circulating slots allow
airflow for proper operation. Guards are lockable
and a key is provided to maintain security.
Minimum 50pcs
Allow 4 weeks.
APPENDIX
CERTIFICATION DESCRIPTIONS
These products are U.L. listed by Underwriters Laboratory, ensuring that the products have passed Underwriters Laboratory’s rigorous
testing procedures for electrical products and have assigned the listing number required for specific electrical codes.
The CSA mark is recognized and accepted throughout Canada and the U.S., at federal, state, provincial, and municipal levels. It means that
the product is certified for the Canadian and US markets, and is certified to the applicable Canadian and US standards.
A product bearing the c ETL us Listed mark signifies that it was tested and meets the minimum requirements of prescribed product safety
standards for US and Canada. Moreover, the mark indicates that the manufacturer’s production site conforms to a range of compliance
measures and is subject to periodic follow-up inspections to verify continued conformance.
PAINT POLICY
Navajo
White
•
•
•
•
Northern
White
Charcoal
Gray
Neutral
Gray
Statuary
Bronze
Desert
Tan
Gloss
Black
Aluminum
For applications that require a primer coat, a Neutral Gray powder coat will be provided as standard color. Consult factory for more information.
All colors are approximate (as nearly correct as can be produced by modern printing). See below for Paint Policy.
There is a setup charge per order and per custom color. See latest pricebook for setup charge.
To minimize the possibility of error when ordering material painted a custom color, a color chip of the custom color must be included with the order. The
chip must be a minimum 3 x 5 in. and be of the same material as the enclosure of the ordered heater (ie. steel or aluminum).
CUSTOM ENGINEERED CONVECTORS
•
•
•
•
Sill Height and Pedestal Convectors are custom engineered for continuous (wall to wall) enclosure with shorter element length.
Special angled inside and outside corners with angles between 45° and 180° (aluminum convectors).
Blank section custom fabricated to any 1/4-in. dimension between 9 and 120 in.
Consult factory representative for special engineering charges and delivery information.
For the latest models and information, please visit our website at www.qmarkmep.com157
NOTES
158
NOTES
For the latest models and information, please visit our website at www.qmarkmep.com159
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising