- No category
advertisement
▼
Scroll to page 2
of 7
TileVision® Interface Connections and Control Codes TV/22/FR2 IR Link Out & In These enable control of external equipment via the IR sensor on the TileVision® and control of the TileVision® from a remote location. RJ12 Connector This connector allows the TileVision® to be integrated with Interactive Hotel TV Systems. RS-232 Port This DB9 connector allows the TileVision® to receive command codes from Home Automation Systems. TileVision® Interface Connections IR Links and RJ12 Connections IR Link Out IR Links The IR Link Out is a 3.5mm mono jack socket. The IR signal sensed by the TileVision® is outputted from this socket to an IR emitter. This will enable the remote control of external equipment, such as a DVD player, from the TileVision®. IR Link Out Connections – IR Emitter Tip Sleeve IR emitter LED positive terminal to the Tip. IR emitter LED negative terminal to the Sleeve. 3.5 mm mono jack plug IR Link In The IR Link In is a 3.5mm stereo jack socket. This socket allows an auxiliary IR sensor to be connected to the TileVision® to enable remote control of the TileVision® from a different point other than the front of the TileVision®. IR Link In Connections – IR Receiver Tip The TileVision® interface will supply +5v DC to power the IR sensor. IR sensor +5v DC terminal to the Tip. Ring Sleeve 3.5 mm stereo jack plug IR sensor signal output terminal to the Ring. IR sensor negative terminal to the Sleeve. RJ12 Connector RJ12 Connections This connector is for Hotel TV System Integration. The RJ12 allows command codes to pass to and from the TileVision®. The RJ12 pin assignment is internally configurable, to allow the connection of various Hotel TV Systems. RJ12 Connector – Standard Configuration Pin No 1 2 3 4 5 6 Function Not Connected Command code from the external equipment to the TileVision® (0V/5V nominal) Not Connected TileVision® On signal from the TileVision® to the external equipment (On = 5V, Standby = 0V nominal) 0V – DC ground Demodulated IR signal from the TileVision® IR sensor to the external equipment (0v/5v nominal) 1 6 1 6 Connector on the Interface PCB 1 6 Male RJ12 connector – front view Male RJ12 connector – top view IR Remote Control IR Remote Control The IR remote control uses the NEC protocol. For a full listing of the IR remote control codes refer to page 4. 1 TileVision® Interface Connections RJ12 Command Code Format Command Codes via the RJ12 Connector RJ12 Command Code Format The codes in the table below are the codes that will be sent to the TileVision via the RJ12 connector. The voltage levels that are accepted as an input on pin 2 of the RJ12 connector (command code from external equipment to the TileVision®) are: HIGH + 5 volts DC LOW 0 volts DC Important: When the input on pin 2 of the RJ12 connector is inactive/idle it must be held HIGH. If pin 2 of the RJ12 connector is held low, all subsequent command codes via the RJ12 connector and via the TileVision® IR receiver (sent from the TileVision® IR remote control) will fail and the TileVision® will be non responsive. Pin 5 of the RJ12 connector is DC ground. The code sequence sent to the RJ12 connector is a DEMODULATED NEC protocol format. First Start Pulse LOW 9.0 ms. Second Start Pulse HIGH 4.5 ms. Logic 1 = LOW 560 µs HIGH 1.69 ms. Logic 0 = LOW 560 µs HIGH 560 µs. Stop Pulse LOW 560 µs. Logic 1 – 2.25 ms Logic 0 – 1.12 ms Stop 560 µs Inactive/idle HIGH Inactive/idle HIGH 560 µs 9 ms Address Code 02FD EA15 4.5 ms 2 TileVision® Interface Connections RJ12 Command Codes – Address 02FD RJ12 Command Codes – Address 02FD RJ 12 Connector Code Listing (Hex) Address 02FD Function Power ON Power OFF Power TOGGLE Source DTV ATV AV SCART Component PC-RGB HDMI 1 HDMI 2 HDMI 3 Media Player 0 1 2 3 4 5 6 7 8 9 Volume Up Volume Down Channel Up Channel Down Page Up Page Down Left Right OK Up Down Code EA FA B0 10 9E 8E DE EB 7E AE CE 1B 0B 8C 65 24 34 F0 E1 D1 C1 81 54 C4 A0 04 55 A5 60 85 C0 50 20 71 D0 Check Sum 15 05 4F EF 61 71 21 14 81 51 31 E4 F4 73 9A DB CB 0F 1E 2E 3E 7E AB 3B 5F FB AA 5A 9F 7A 3F AF DF 8E 2F Function INFO Zoom Mute P. Mode S. Mode Sleep FAV PVR List 9 g Rec / Home 7 8 4/; Exit Timeshift Menu Back EPG SUB. T Audio TTX / Mix Index Reveal Cancel Hold Size List RED GREEN YELLOW BLUE Code 05 15 41 B4 B5 35 01 75 74 31 21 84 F4 D4 61 B1 E0 E4 90 51 44 11 95 80 94 70 A1 F5 40 64 A4 25 E5 Check Sum FA EA BE 4B 4A CA FE 8A 8B CE DE 7B 0B 2B 9E 4E 1F 1B 6F AE BB EE 6A 7F 6B 8F 5E 0A BF 9B 5B DA 1A The above codes are sent LEAST significant bit first. 0 0000 1248 LSB Least Significant Bit first - 0 2 F D 0 4 F B Address Code & Check Sum 2 F D 0 4 F 0100 1111 1011 0000 0010 1111 1248 1248 1248 1248 1248 1248 Weighting B 1101 1248 MSB 3 TileVision® Interface Connections IR Remote Control Codes – NEC Protocol – Address 20DF IR Remote Control Codes – NEC Protocol – Address 20DF To program an IR remote control to transmit an IR signal to operate the TileVision, the codes in the table below must be entered. IR Code Listing (Hex) Address 20DF Function Power ON Power OFF Power TOGGLE Source DTV ATV AV SCART Component PC-RGB HDMI 1 HDMI 2 HDMI 3 Media Player 0 1 2 3 4 5 6 7 8 9 Volume Up Volume Down Channel Up Channel Down Page Up Page Down Left Right OK Up Down Code AE AF 0B 01 E9 E8 ED EB E7 EA EC B1 B0 C8 56 42 43 0F 1E 1D 1C 18 45 4C 0A 40 55 5A 06 58 0C 05 02 17 0D Check Sum 51 50 F4 FE 16 17 12 14 18 15 13 4E 4F 37 A9 BD BC F0 E1 E2 E3 E7 BA B3 F5 BF AA A5 F9 A7 F3 FA FD E8 F2 Function INFO Zoom Mute P. Mode S. Mode Sleep FAV PVR List 9 g Rec / Home 7 8 4/; Exit Timeshift Menu Back EPG SUB. T Audio TTX / Mix Index Reveal Cancel Hold Size List RED GREEN YELLOW BLUE Code 50 51 14 4B 5B 53 10 57 47 13 12 48 4F 4D 16 1B 0E 4E 09 15 44 11 59 08 49 07 1A 5F 04 46 4A 52 5E Check Sum AF AE EB B4 A4 AC EF A8 B8 EC ED B7 B0 B2 E9 E4 F1 B1 F6 EA BB EE A6 F7 B6 F8 E5 A0 FB B9 B5 AD A1 4 TileVision® Interface Connections The RS-232 Port RS-232 Port The RS-232 Port The RS-232 port is a DB9 male connector. This connector allows Home Automation Systems to send command codes directly to the TileVision®. The TileVision® will only receive RS-232 codes, it does not transmit codes. To connect to the RS-232 port a DB9 MALE connector must be used. RS-232 Protocol Command Code Sequence Baud Rate: 38400 A0 F0 55 FF <IR Code> <Check Sum> Bits:8 The time of the command sequence must be < 500 ms. Parity:None The interval time of two continuous command sequences must be > 500 ms. Stop Bit: 1 RS 232 Code Listing (Hex) Function Power ON Power OFF Power TOGGLE Source DTV ATV AV SCART Component PC-RGB HDMI 1 HDMI 2 HDMI 3 Media Player 0 1 2 3 4 5 6 7 8 9 Volume Up Volume Down Channel Up Channel Down Page Up Page Down Left Right OK Up Down Code AE AF 0B 01 E9 E8 ED EB E7 EA EC B1 B0 C8 56 42 43 0F 1E 1D 1C 18 45 4C 0A 40 55 5A 06 58 0C 05 02 17 0D Check Sum 51 50 F4 FE 16 17 12 14 18 15 13 4E 4F 37 A9 BD BC F0 E1 E2 E3 E7 BA B3 F5 BF AA A5 F9 A7 F3 FA FD E8 F2 Function INFO Zoom Mute P. Mode S. Mode Sleep FAV PVR List 9 g Rec / Home 7 8 4/; Exit Timeshift Menu Back EPG SUB. T Audio TTX / Mix Index Reveal Cancel Hold Size List RED GREEN YELLOW BLUE Code 50 51 14 4B 5B 53 10 57 47 13 12 48 4F 4D 16 1B 0E 4E 09 15 44 11 59 08 49 07 1A 5F 04 46 4A 52 5E Check Sum AF AE EB B4 A4 AC EF A8 B8 EC ED B7 B0 B2 E9 E4 F1 B1 F6 EA BB EE A6 F7 B6 F8 E5 A0 FB B9 B5 AD A1 5 Porter Lancastrian Limited Lower Healey Business Park · Froom Street · Chorley · Lancashire · UK · PR6 9AR Tel: 0870 871 0111 · Fax: 0870 871 0112 Sales: [email protected] · Web: www.tilevision.tv Control Codes 04/14
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement