TileVision® Interface Connections and Control Codes TV/22/FR2


Add to my manuals
7 Pages

advertisement

TileVision® Interface Connections and Control Codes TV/22/FR2 | Manualzz
TileVision® Interface Connections
and Control Codes
TV/22/FR2
IR Link Out & In
These enable control of external equipment via the IR sensor on
the TileVision® and control of the TileVision® from a remote location.
RJ12 Connector
This connector allows the TileVision® to be integrated with Interactive Hotel TV Systems.
RS-232 Port
This DB9 connector allows the TileVision® to receive command codes from
Home Automation Systems.
TileVision® Interface Connections
IR Links and RJ12 Connections
IR Link Out
IR Links
The IR Link Out is a 3.5mm mono jack socket. The IR signal sensed by the TileVision® is outputted from this socket to an
IR emitter. This will enable the remote control of external equipment, such as a DVD player, from the TileVision®.
IR Link Out Connections – IR Emitter
Tip Sleeve
IR emitter LED positive terminal to the Tip.
IR emitter LED negative terminal to the Sleeve.
3.5 mm mono jack plug
IR Link In
The IR Link In is a 3.5mm stereo jack socket. This socket allows an auxiliary IR sensor to be connected to the TileVision®
to enable remote control of the TileVision® from a different point other than the front of the TileVision®.
IR Link In Connections – IR Receiver
Tip
The TileVision® interface will supply +5v DC to power the IR sensor.
IR sensor +5v DC terminal to the Tip.
Ring
Sleeve
3.5 mm stereo jack plug
IR sensor signal output terminal to the Ring.
IR sensor negative terminal to the Sleeve.
RJ12 Connector
RJ12 Connections
This connector is for Hotel TV System Integration. The RJ12 allows command codes to pass to and from the TileVision®.
The RJ12 pin assignment is internally configurable, to allow the connection of various Hotel TV Systems.
RJ12 Connector – Standard Configuration
Pin No
1
2
3
4
5
6
Function
Not Connected
Command code from the external equipment to the TileVision® (0V/5V nominal)
Not Connected
TileVision® On signal from the TileVision® to the external equipment (On = 5V, Standby = 0V nominal)
0V – DC ground
Demodulated IR signal from the TileVision® IR sensor to the external equipment (0v/5v nominal)
1 6
1 6
Connector on the Interface PCB
1 6
Male RJ12 connector – front view
Male RJ12 connector – top view
IR Remote Control
IR Remote Control
The IR remote control uses the NEC protocol.
For a full listing of the IR remote control codes refer to page 4.
1
TileVision® Interface Connections
RJ12 Command Code Format
Command Codes via the RJ12 Connector
RJ12 Command Code Format
The codes in the table below are the codes that will be sent to the TileVision via the RJ12 connector.
The voltage levels that are accepted as an input on pin 2 of the RJ12 connector (command code from external
equipment to the TileVision®) are:
HIGH + 5 volts DC LOW 0 volts DC
Important: When the input on pin 2 of the RJ12 connector is inactive/idle it must be held HIGH. If pin 2 of the RJ12
connector is held low, all subsequent command codes via the RJ12 connector and via the TileVision® IR receiver (sent
from the TileVision® IR remote control) will fail and the TileVision® will be non responsive.
Pin 5 of the RJ12 connector is DC ground.
The code sequence sent to the RJ12 connector is a DEMODULATED NEC protocol format.
First Start Pulse LOW 9.0 ms.
Second Start Pulse HIGH 4.5 ms.
Logic 1 = LOW 560 µs HIGH 1.69 ms.
Logic 0 = LOW 560 µs HIGH 560 µs.
Stop Pulse LOW 560 µs.
Logic 1 – 2.25 ms
Logic 0 – 1.12 ms
Stop 560 µs
Inactive/idle
HIGH
Inactive/idle
HIGH
560 µs
9 ms
Address
Code
02FD
EA15
4.5 ms
2
TileVision® Interface Connections
RJ12 Command Codes – Address 02FD
RJ12 Command Codes – Address 02FD
RJ 12 Connector Code Listing (Hex) Address 02FD
Function
Power ON
Power OFF
Power TOGGLE
Source
DTV
ATV
AV
SCART
Component
PC-RGB
HDMI 1
HDMI 2
HDMI 3
Media Player
0
1
2
3
4
5
6
7
8
9
Volume Up
Volume Down
Channel Up
Channel Down
Page Up
Page Down
Left
Right
OK
Up
Down
Code
EA
FA
B0
10
9E
8E
DE
EB
7E
AE
CE
1B
0B
8C
65
24
34
F0
E1
D1
C1
81
54
C4
A0
04
55
A5
60
85
C0
50
20
71
D0
Check Sum
15
05
4F
EF
61
71
21
14
81
51
31
E4
F4
73
9A
DB
CB
0F
1E
2E
3E
7E
AB
3B
5F
FB
AA
5A
9F
7A
3F
AF
DF
8E
2F
Function
INFO
Zoom
Mute
P. Mode
S. Mode
Sleep
FAV
PVR List
9

g
Rec / Home
7
8
4/;
Exit
Timeshift
Menu
Back
EPG
SUB. T
Audio
TTX / Mix
Index
Reveal
Cancel
Hold
Size
List
RED
GREEN
YELLOW
BLUE
Code
05
15
41
B4
B5
35
01
75
74
31
21
84
F4
D4
61
B1
E0
E4
90
51
44
11
95
80
94
70
A1
F5
40
64
A4
25
E5
Check Sum
FA
EA
BE
4B
4A
CA
FE
8A
8B
CE
DE
7B
0B
2B
9E
4E
1F
1B
6F
AE
BB
EE
6A
7F
6B
8F
5E
0A
BF
9B
5B
DA
1A
The above codes are sent LEAST significant bit first.
0
0000
1248
LSB
Least Significant Bit first - 0 2 F D 0 4 F B
Address
Code & Check Sum
2
F
D
0
4
F
0100
1111
1011
0000
0010
1111
1248
1248
1248
1248
1248
1248
Weighting
B
1101
1248
MSB
3
TileVision® Interface Connections
IR Remote Control Codes – NEC Protocol – Address 20DF
IR Remote Control Codes – NEC Protocol – Address 20DF
To program an IR remote control to transmit an IR signal to operate the TileVision, the codes in the table below must be
entered.
IR Code Listing (Hex) Address 20DF
Function
Power ON
Power OFF
Power TOGGLE
Source
DTV
ATV
AV
SCART
Component
PC-RGB
HDMI 1
HDMI 2
HDMI 3
Media Player
0
1
2
3
4
5
6
7
8
9
Volume Up
Volume Down
Channel Up
Channel Down
Page Up
Page Down
Left
Right
OK
Up
Down
Code
AE
AF
0B
01
E9
E8
ED
EB
E7
EA
EC
B1
B0
C8
56
42
43
0F
1E
1D
1C
18
45
4C
0A
40
55
5A
06
58
0C
05
02
17
0D
Check Sum
51
50
F4
FE
16
17
12
14
18
15
13
4E
4F
37
A9
BD
BC
F0
E1
E2
E3
E7
BA
B3
F5
BF
AA
A5
F9
A7
F3
FA
FD
E8
F2
Function
INFO
Zoom
Mute
P. Mode
S. Mode
Sleep
FAV
PVR List
9

g
Rec / Home
7
8
4/;
Exit
Timeshift
Menu
Back
EPG
SUB. T
Audio
TTX / Mix
Index
Reveal
Cancel
Hold
Size
List
RED
GREEN
YELLOW
BLUE
Code
50
51
14
4B
5B
53
10
57
47
13
12
48
4F
4D
16
1B
0E
4E
09
15
44
11
59
08
49
07
1A
5F
04
46
4A
52
5E
Check Sum
AF
AE
EB
B4
A4
AC
EF
A8
B8
EC
ED
B7
B0
B2
E9
E4
F1
B1
F6
EA
BB
EE
A6
F7
B6
F8
E5
A0
FB
B9
B5
AD
A1
4
TileVision® Interface Connections
The RS-232 Port
RS-232 Port
The RS-232 Port
The RS-232 port is a DB9 male connector. This connector allows Home Automation Systems to send command codes
directly to the TileVision®.
The TileVision® will only receive RS-232 codes, it does not transmit codes.
To connect to the RS-232 port a DB9 MALE connector must be used.
RS-232 Protocol
Command Code Sequence
Baud Rate: 38400
A0 F0 55 FF <IR Code> <Check Sum>
Bits:8
The time of the command sequence must be < 500 ms.
Parity:None
The interval time of two continuous command sequences must be > 500 ms.
Stop Bit:
1
RS 232 Code Listing (Hex)
Function
Power ON
Power OFF
Power TOGGLE
Source
DTV
ATV
AV
SCART
Component
PC-RGB
HDMI 1
HDMI 2
HDMI 3
Media Player
0
1
2
3
4
5
6
7
8
9
Volume Up
Volume Down
Channel Up
Channel Down
Page Up
Page Down
Left
Right
OK
Up
Down
Code
AE
AF
0B
01
E9
E8
ED
EB
E7
EA
EC
B1
B0
C8
56
42
43
0F
1E
1D
1C
18
45
4C
0A
40
55
5A
06
58
0C
05
02
17
0D
Check Sum
51
50
F4
FE
16
17
12
14
18
15
13
4E
4F
37
A9
BD
BC
F0
E1
E2
E3
E7
BA
B3
F5
BF
AA
A5
F9
A7
F3
FA
FD
E8
F2
Function
INFO
Zoom
Mute
P. Mode
S. Mode
Sleep
FAV
PVR List
9

g
Rec / Home
7
8
4/;
Exit
Timeshift
Menu
Back
EPG
SUB. T
Audio
TTX / Mix
Index
Reveal
Cancel
Hold
Size
List
RED
GREEN
YELLOW
BLUE
Code
50
51
14
4B
5B
53
10
57
47
13
12
48
4F
4D
16
1B
0E
4E
09
15
44
11
59
08
49
07
1A
5F
04
46
4A
52
5E
Check Sum
AF
AE
EB
B4
A4
AC
EF
A8
B8
EC
ED
B7
B0
B2
E9
E4
F1
B1
F6
EA
BB
EE
A6
F7
B6
F8
E5
A0
FB
B9
B5
AD
A1
5
Porter Lancastrian Limited
Lower Healey Business Park · Froom Street · Chorley · Lancashire · UK · PR6 9AR
Tel: 0870 871 0111 · Fax: 0870 871 0112
Sales: [email protected] · Web: www.tilevision.tv
Control Codes 04/14

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement