HX-40/40AM/ 40DAM HX-40/40AM/ 40DAM

HX-40/40AM/ 40DAM HX-40/40AM/ 40DAM
NO.59-1501-3
INSTALLATION INSTRUCTIONS
High Mount
Outdoor Detector
N219
HX-40/40AM/
40DAM
CONTENTS
1 INSTALLATION PRECAUTIONS ............2
1-1 BEFORE INSTALLATION ................2
1-2 PARTS IDENTIFICATION ................3
1-3 KNOCKOUTS ..................................4
1-4 DETECTION AREA..........................5
1-5 DETERMINATION OF PIR
DETECTION LENGTH ....................5
2 INSTALLATION .......................................6
2-1 MOUNTING WITH BRACKET .........6
2-2 ADJUSTING THE VERTICAL
ANGLE.............................................8
2-3 MOUNTING WITHOUT
BRACKET ........................................9
2-4 WIRING .........................................10
2-5 WALL TAMPER (OPTION) ............ 11
3 WALK TEST..........................................12
4 SETTING ..............................................13
5 AREA ADJUSTMENT ...........................16
6 LED INDICATION .................................17
7 SPECIFICATIONS ................................18
7-1 SPECIFICATIONS .........................18
7-2 DIMENSIONS ................................19
HX-40
2 PIRs standard model
HX-40AM
HX-40 with anti-masking
HX-40DAM HX-40AM with micro-wave
• 3.0 m high mount detection area (12.0 m)
• Unique pyro element
• Intelligent AND logic
• Dual signal processing logic
• Vegetation sway analysis logic
• Ideal detection area setting
• Digital anti-masking (AM/DAM model only)
• Microwave range selector (DAM model only)
-1-
1
INSTALLATION PRECAUTIONS
1-1
BEFORE INSTALLATION
Warning
Failure to follow the instructions provided with this indication and improper
handling may cause death or serious injury.
Caution
Failure to follow the instructions provided with this indication and improper
handling may cause injury and/or property damage.
The check
mark indicates recommendation.
The nix
sign indicates prohibition.
Warning
Warning
Caution
Do not repair or modify
product
Keep product away from water Mount the unit securely
Mounting height
Keep the detector parallel to the ground.
2.5 m – 3.0 m
(8'2" – 9'10")
Parallel
Tilt
Consider the direction a person is approaching from, as well as the detection area.
Install the detector in a place where it is free from false alarm factors. For example:
• Sunlight and reflection
• Heat source
• Objects moving in the wind
-2-
HX-40
HX-40AM
HX-40DAM
-Precautions for installing two or more sensors
Do not install two or more HX-40DAM’s units side-by-side or face-to-face. Instead, install them
back-to-back. If mounting on the same wall, be sure they are at least 1.0 m (3'3") apart from
each other.
1.0 m (3'3") or more
1-2
Less than 1.0 m (3'3")
PARTS IDENTIFICATION
Bracket base
Base
Screw (3 × 10 mm)
Terminals
Main unit
Hood
PIR sensor
(Do not touch)
Anti-masking infrared LED
(HX-40AM/DAM only)
Bracket
Shaft cover
Lock screw* (M4 × 35 mm)
Screw (4 × 20 mm)
Microwave unit
(HX-40DAM only)
(Do not touch)
LED indicator
Lens
Cover
Lock screw
Area masking seal
Screw kit
For joint
For wall mounting
For hood
Screw (4 × 20 mm)
Screw (4 × 20 mm)
Screw (3 × 10 mm)
*Lock screw attached on bracket base
-3-
1-3
KNOCKOUTS
Bracket
Main unit
Wiring Hole
Wiring
knockout
(Off-the-shelf) magnet switch
installation position
Wiring Hole
Wiring sponge pad
Do not touch
For bracket
For wall fastening/bracket fastening
Up-Down lock screw (installation pitch 83.5 mm (3.29"))
-4-
For wall
fastening
Up-Down
For switch
lock screw
box fastening
For main unit fastening
Adjustment screw
1-4
DETECTION AREA
Side view
Top view
(Mounting height: 3.0 m (9'10"))
0'
10'
30'
(ft.) (m)
8
MW
PIR
3.0 m
10'
20'
30'
40'
40'
(ft.)
40' (ft.)
12.0 m
(ft.)
10'
20'
2
4
6
8
10
12
(m)
6
4
10'
0'
10'
40' (ft.)
0'
PIR
10'
4
PIR
20'
• Vertical angle: 1 click (2.5°) upward
(Refer to “caution” in 2-2).
1-5
0
2
MW
2.5 m
0'
30'
12.0 m
(ft.)
10'
5'
20'
10°
2
(Mounting height: 2.5 m (8'2"))
85°
0'
20°
5'
20'
30°
40°
0'
6
MW
8
(ft.) (m)
DETERMINATION OF PIR DETECTION LENGTH
To adjust the detection length, apply the masking seals to the back of the lens according to
the required detection length. Three types of masking seals are provided. Combine them
according to the detection length required.
Apply masking seal directly on the back side of the lens.
4.0 m (13'1")
1
2
1
3
2
For microwave detection setting please refer to “4 SETTING”.
-5-
3.0 m (9'10")
5.5 m (18'1")
3.0 m (9'10")
1
3.0 m (9'10")
9.0 m (29'6")
2
INSTALLATION
Use the bracket for normal installation. The unit may be mounted directly on the wall, without
the bracket, only if the following three conditions are not;
• The mounting height 3.0 m (9'10").
• Horizontal direction adjustment is unnecessary.
• The ground is level.
2-1
MOUNTING WITH BRACKET
Using the bracket makes it possible to adjust the unit horizontally by ±90°.
In cases where the ground is uneven and/or not parallel with the base of the unit, it is possible
to adjust the unit vertically by ±20°.
Caution>>
Do not change the detection
length with bracket.
Use the masking seal to
adjust the detection length.
90°
90°
20°
20°
1
Remove the Up-Down lock screw.
2
Push the shaft cover clip straightforwardly with
your thumb. In case the clip is stuck, use a
suitable tool. e.g. back side of a screw driver.
Shaft cover
Shaft cover clip
3
Loosen the adjustment screw two turns.
4
Tilt the bracket about 45° and pass
through the wire.
In
Adjustment screw
Out
Caution>>
Do not loosen the
screw too much.
It may disassemble.
-6-
Determine the horizontal direction (left or
right) of the detector before installing the
bracket on the wall.
5
To the right
6
Open the wiring knockout.
To the left
Wiring knockout
Open the Up-Down lock screw knockout
for connecting the bracket.
7
8
Tighten screws 1 and 2, adjust the bracket
angle (refer to 2-2), then tighten screw 3.
Perform an area check. If re-adjustment is
required, loosen screw 3 and change the
bracket angle.
After the adjustment is complete, tighten
screw 3 again.
In
Knockout with 4 × 20
tapping screw (screwkit)
Wiring
hole Wiring
sponge pad
Out
14 × 20 screw
34 × 35 Up-Down
lock screw
24 × 20 screw
Tighten the adjustment screw clockwise.
9
Adjustment
screw
11
Install the shaft cover into place.
-7-
to the terminal and install the main
10 Wire
unit and lens on the base.
2-2
ADJUSTING THE VERTICAL ANGLE
For best performance, install detector parallel to the ground.
Decide the detection length. If you choose 9.0 m/5.5 m/4.0 m, mask the unnecessary lens with
masking seals. Refer to the 1-5 for the details.
Perform the walk test to check
if detector is parallel to the
ground.
3.0 m (9'10")
12.0 m (40')
* This is the case to have 12 m detection length.
If the detection length is
shorter than the designated
one (refer to page 5), change
the detector angle upward.
If the detection length is
equal to the designated
one, adjustments have
been completed.
If the detection length is
longer than the designated
one (refer to page 5), change
the detector angle downward.
Caution>>
If the base of the unit is already parallel to the ground,
• Do not change the detection length by tilting the unit up or down. Detection length should
be adjusted with masking seal. Refer to 1-5 and 2-1 for the details.
0°
Example (the ground is level)
0° is the right setting for 3.0 m
(9'10") height installation.
Adjust 1 click (2.5° upward) for 2.5 m
(8'2") height installation.
-8-
2 clicks (5°)
4 clicks (10°)
2-3
1
MOUNTING WITHOUT BRACKET
Open the wiring knockout with suitable
tool e.g. screwdriver.
2
Pull the wire through the base knockout.
In
Out
Wiring sponge pad
3
Fasten the base to the wall.
4
-9-
Install main unit after wiring to the
terminal.
WIRING
TAMPER
(N.C.)
AUX
INPUT
(N.C.)
TROUBLE
SP
OUTPUT
T.O.(N.C.)
SP
POWER INPUT (+) (9.5 - 18VDC)
POWER INPUT (-) (9.5 - 18VDC)
ALARM OUTPUT (N.C.)
ALARM OUTPUT (COM)
HX-40DAM
12 V
14 V
120 m
250 m
(390')
(820')
180 m
390 m
(590')
(1,280')
290 m
630 m
(950')
(2,070')
SPARE (Non short)
TROUBLE OUTPUT
(N.C.)
AUX INPUT
(N.C.)
HX-40AM
HX-40DAM
TAMPER OUTPUT
(N.C.) *1
Power wires should not exceed the following lengths.
HX-40
HX-40AM
WIRE GAUGE
12 V
14 V
12 V
14 V
160
m
360
m
140
m
310
m
AWG22 (0.33 mm2)
(520')
(1,180')
(460')
(1,020')
260 m
560 m
230 m
490 m
AWG20 (0.52 mm2)
(850')
(1,840')
(750')
(1,610')
410 m
900 m
360 m
780 m
AWG18 (0.83 mm2)
(1,350')
(2,950')
(1,180')
(2,560')
ALARM OUTPUT (N.O.)
2-4
N.O. COM N.C. –
+
ALARM
POWER
9.5-18VDC
HX-40
TAMPER
(N.C.)
AUX
INPUT
(N.C.)
SP
SP
N.O. COM N.C. –
+
ALARM
POWER
9.5-18VDC
*1: TAMPER terminals to be connected to a 24 hour supervisory loop.
- 10 -
2-5
WALL TAMPER (OPTION)
Universal magnet switch may be mounted as a wall tamper.
Installation space for universal magnet switch is provided on the back of the main unit and the
bracket.
Maximum size of an applicable universal magnet switch: D 9 mm (0.35'') × W 40 mm (1.57'') × H 9
mm (0.35'').
Universal magnet switch on the market assist is not included.
Main unit
Bracket
Wiring Hole
Magnet switch
(Bracket side)
Magnet switch (Wall side) installation position
installation position
Magnet switch (Wall side)
installation position
Magnet switch (Base side) installation position
-Installation
1
Install the universal magnet switch (wall
side) to the wall. To determine the install
position, use the “Install position template”
provided on the inside cover of the product
package.
3
Install the other portion of the universal magnet switch to the back of the main unit or the
bracket. Pull the wiring through the knockouts.
2
When not using the bracket
1
2
4
Fix
In
Wiring sponge pad
Out
3
- 11 -
Open the wiring knockout with suitable
tool e.g. screwdriver.
When using the bracket
1
Fix
In
4
In
2
Tilt the bracket about 45° and
pass through the wire.
3
In
Out
6
5
Wiring
sponge pad
Out
Magnet
switch
4
3
Install the bracket and the main unit to
the wall surface.
5
Connect the universal magnet switch wiring
to the tamper terminal of the main unit.
2
Check that the detector detects an
object in the intended detection area.
The installation has been successful if
the LED lights for two seconds after a
person walks into the detection area.
WALK TEST
1
Set the DIP switch 1 (LED ON/OFF) to
“ON”.
Detected
Not detected
Note>>
The switch is set “ON” by factory
default.
Note>>
For the walk test, move more than 1.0 m
(3'3") away from the detector.
3
If the LED indication is not required at all
times, set the DIP switch 1 (LED ON/
OFF) to “OFF”.
- 12 -
4
SETTING
Do not touch
DIP switch
1.
2.
3.
4.
5.
6.
MW range
selector
LED ON/OFF
PIR IMMUNITY
AUX INPUT
TROUBLE OUTPUT
MICROWAVE IMMUNITY
(Reserved)
MW sensitivity
adjustment
HI
STD
OFF
Anti masking
sensitibity
selector
Do not touch
PIR sensitivity selector
-LED ON/OFF
DIP switch
POSITION
ON
(Factory
default)
OFF
OFF
FUNCTION
The LED lights when someone is
detected.
The LED does not light even if
someone is detected.
ON
-PIR IMMUNITY
STD
1
HX-40
HX-40AM
HX-40DAM
DIP switch
2
HX-40
HX-40AM
HX-40DAM
POSITION
FUNCTION
STD
(Factory
default)
PIR IMMUNITY logic is not activated.
IMMUNITY
PIR IMMUNITY logic is activated. Use
this under harsh environment (e.g.
small animal).
IMMUNITY
- 13 -
-AUX INPUT
DIP switch
3
HX-40
HX-40AM
HX-40DAM
By connecting a satellite unit (another warning sensor), you can extend the detection area
and correct false alarms. As a satellite unit, you can use any general no-voltage contact
output (NC) warning sensor, including the following.
<Infrared (AIR) sensors, thermal line (PIR) sensors, universal magnet switches, etc.>
POSITION
FUNCTION
AND
(Factory
default)
When both the main unit and the satellite detect someone, the
alarm is output.
Set to this when not connecting a satellite unit.
OR
AND
OR
When either the main unit or the satellite detects someone,
the alarm is output.
Notes>>
• The alarm does not output unless both the main unit and the satellite
detect someone within 60 sec.
• If the OR mode is selected without a satellite unit connected, the alarm
is generated continuously.
-TROUBLE OUTPUT
DIP switch
4
HX-40
HX-40AM
HX-40DAM
Trouble output is used for anti-masking signal.
When an object is placed close to the lens surface, for a period of more than 180 sec., the IR
Anti-Masking circuit is activated and generates a trouble signal.
POSITION
OFF
ON
FUNCTION
ON
(Factory
default)
Anti-masking signal is output from TROUBLE OUTPUT
terminal.
OFF
Anti-masking signal is output from both TROUBLE and
ALARM OUTPUT terminal.
Note>>
Use this when not wiring a detected trouble input terminal on the control
panel.
-MICROWAVE IMMUNITY
DIP switch
POSITION
STD
(Factory
default)
IMMUNITY
STD
5
HX-40
HX-40AM
HX-40DAM
FUNCTION
MICRO WAVE IMMUNITY logic is not activated.
MICRO WAVE IMMUNITY logic is activated. Use this
under harsh environment (e.g. vegetation sway).
IMMUNITY
- 14 -
-MW RANGE SELECTOR/MW SENSITIVITY ADJUSTMENT
DETECTION AREA
(SIDE VIEW)
PIR AREA SETTING
MW RANGE
SELECTOR
LONG
12.0 m
(40')
SHORT
MW SENSITIVITY
ADJUSTMENT
MID
M
0
PIR
LONG
SHORT
1
9.0 m
(29'6'')
H
HIGH
M
SHORT
0
PIR
MW
LONG
SHORT
1
2
L
MW
Factory default
5.5 m
(18'1'')
HX-40
HX-40AM
HX-40DAM
RANGE SELECTOR/
SENSITIVITY
ADJUSTMENT
SHORT
0
L
H
MID
M
PIR
MW
LONG
4.0 m
(13'1'')
SHORT
1
3
2
SHORT
0
PIR
MW
LONG
- 15 -
L
H
LOW
M
L
H
HX-40
HX-40AM
HX-40DAM
PIR
-PIR SENSITIVITY
SENSITIVITY SELECTOR
POSITION
HIGH
FUNCTION
HIGH
High sensitivity
MIDDLE
(Factory default)
MIDDLE
Middle sensitivity
LOW
LOW
Low sensitivity
HX-40
HX-40AM
HX-40DAM
ANTI-MASKING
-ANTI-MASKING SENSITIVITY
SENSITIVITY SELECTOR
POSITION
FUNCTION
HIGH
HIGH
STD
(Factory default)
STD
OFF
Standard sensitivity
Disabled
Caution>>
OFF
When closing the cover, do not leave any object within
1 meter from the unit.
AREA ADJUSTMENT
-DETECTION LENGTH ADJUSTMENT
To limit the detection length, apply the appropriate masking seal. Note that there are three
different types of seal.
9.0 m (29'6")
2
3.0 m (9'10")
1
3.0 m (9'10")
1
4.0 m (13'1")
5.5 m (18'1")
3.0 m (9'10")
5
High sensitivity
1
3
2
-AREA MASKING
Pasting on example for
masking No. 5 and No. 6
1
2
1
2
3
4
5
6
7
8
9
3
Area masking seal
4
0
5
6
7
8
9
- 16 -
56
6
LED INDICATION
Red
Yellow
(HX-40DAM only)
Blink
Light
OFF
Green
(HX-40DAM only)
-HX-40/40AM
DETECTOR CONDITION
LED INDICATOR (RED ONLY)
Warm-up
Blinks for approx. 60 sec.
Alarm
Lights for 2 sec.
Trouble
output
Anti-Masking
booting
(Anti-Masking
start up)
Blinks 2 times and goes off for 5 sec. and then repeats for 180 sec.
Masking detection
Blinks 3 times and goes off for 3 sec. and then repeats.
-HX-40DAM
DETECTOR CONDITION
LED INDICATOR
Warm-up
Blinks for approx. 60 sec.
Alarm
Red lights for 2 sec.
PIR detection
Green lights for 2 sec.
MW detection
Yellow lights for 2 sec.
Trouble
output
Anti-Masking
booting
(Anti-Masking
start up)
Green and Red blink 2 times simultaneously and go off for
5 sec. This sequence is repeated for 180 sec.
Masking detection
Green and Red blink 3 times simultaneously and go off for
3 sec. This sequence is repeated.
- 17 -
7
SPECIFICATIONS
7-1
SPECIFICATIONS
Model
HX-40
HX-40AM
Detection method
Passive infrared
PIR Coverage
HX-40DAM
Passive infrared & Microwave
12.0 m (40') 85° wide / 94 zones
PIR distance limit
4.0 m, 5.5 m, 9.0 m (13'1", 18'1", 29'6")
Detectable speed
0.3 m/s – 1.5 m/s (1'/s – 4'11"/s)
Sensitivity
2.0°C (3.6°F) at 0.6 m/s
Power input
Current draw
9.5 – 18 V DC
35 mA (max.)
at 12 V DC
40 mA (max.)
at 12 V DC
Alarm period
50 mA (max.)
at 12 V DC
2.0 ±1 sec.
Warm-up period
Approx. 60 sec. (LED blinks)
Alarm output
Form C 28 V DC 0.2 A (max.)
Tamper output
N.C. 28 V DC, 0.1 A (max.) N.C. open when cover removed.
Trouble output
–
N.C. 28 V DC, 0.1 A (max.)
Aux input
N.C. 28 V DC, 0.1 A (max.)
Red:
Warm-up, Alarm, Trouble
LED indicator
Red: Warm-up,
Alarm
RF interference
Red: Warm-up,
Alarm,
Trouble
-20 – +60°C (-4 – +140°F)
Environment humidity
95% max.
Weatherproof
IP55
Mounting
Wall
Mounting height
2.5 – 3.0 m (8'2" – 9'10")
Bracket adjust angle
Accessories
Yellow:
Warm-up, MW detect
No alarm 10 V/m
Operating temperature
Weight
Green:
Warm-up, PIR detect, Trouble
Vertical: ±20° Horizontal: ±95°
600 g (21.2 oz.)
700 g (24.7 oz.)
Bracket, Hood, Area masking seal, Screw (3 × 10 mm) × 2, Screw (4 × 20 mm) × 4
*Specifications and designs are subject to change without prior notice.
- 18 -
DIMENSIONS
Using bracket and hood
99 (3.90)
148 (5.83)
205 (8.07)
266 (10.47)
Without bracket and hood
Unit: mm (inch)
- 19 -
92 (3.62)
197.5 (7.78)
7-2
Unit: mm (inch)
NOTE
The following statement will be provided with the equipment as required by Article 6.3 of the
R&TTE Directive, 1999/5/EC.
The Optex HX series are in conformity with all essential requirements of the R&TTE Directive
(1999/5/EC). This equipment has been assessed to the following standards:
EN 300 440-1: 2009
EN 50130-4: 2004 including amendment 2: 2003
EN 60950-1: 2006+A11: 2009
This product is marked with
which signifies conformity with Class II product
requirements specified in the R&TTE Directive.
The following table indicates the areas of intended use of the equipment and any known
restrictions. For countries not included in this list, please consult the responsible Spectrum
Management Agency.
Country of intended use Restrictions Country of intended use Restrictions
Austria
Belgium
Denmark
Finland
France
Greece
Ireland
Italy
9.900GHz
10.525GHz
10.525GHz
9.900GHz
10.587GHz
10.525GHz
10.587GHz
10.525GHz
Luxembourg
The Netherlands
Spain
Sweden
United Kingdom
Other non-EU: Iceland
Norway
Switzerland
10.525GHz
10.525GHz
10.525GHz
10.525GHz
10.587GHz
10.525GHz
10.525GHz
10.525GHz
FCC ID : DC9 OPMW
IC : 4012A-OPMW
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
The HX-40 series is only a part of a complete system, therefore we cannot accept complete
responsibility for any damages or other consequences resulting from an intrusion.
OPTEX CO., LTD. (JAPAN) OPTEX INCORPORATED (USA)
(ISO 9001 Certified)
(ISO 14001 Certified)
5-8-12 Ogoto Otsu
Shiga 520-0101
JAPAN
TEL:+81-77-579-8670
FAX:+81-77-579-8190
URL:http://www.optex.co.jp/e/
OPTEX SECURITY Sp. z o. o. (POLAND)
TEL:+1-909-993-5770
Tech:(800)966-7839
URL:http://www.optexamerica.com/
TEL:+48-22-598-06-55
URL:http://www.optex.com.pl/
OPTEX (EUROPE) LTD. (UK)
OPTEX KOREA CO., LTD. (KOREA)
TEL:+44-1628-631000
URL:http://www.optexeurope.com/
TEL:+82-2-719-5971
URL:http://www.optexkorea.com/
OPTEX SECURITY SAS (FRANCE) OPTEX (DONGGUAN) CO., LTD.
TEL:+33-437-55-50-50
SHENZHEN OFFICE (CHINA)
URL:http://www.optex-security.com/
- 20 -
TEL:+86-755-33302950
URL:http://www.optexchina.com/
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising