Data Sheets - Honeywell Analytics
Series
multi-gas detectors
VOCs
Protect yourself
CO2
Simultaneously monitor and display up to five atmospheric
LEL
hazards with the GasAlertMicro 5 Series. Adaptable to a
variety of applications, the GasAlertMicro 5 Series has an
H2S
extensive selection of user-settable field options and is
available as either a standard toxic gas model, a PID model
CO
for the detection VOCs, or an IR model for CO2 detection.
Use the passcode function to prevent unauthorized
modifications of the instrument’s settings. Compatible with
O2
BW’s MicroDock II automatic test and calibration system,
the GasAlertMicro 5 Series is unparalleled in its versatility,
SO2
performance and overall value.
PH3
NH3
NO2
HCN
Cl2
Generation 2 pump
with visible integrated filter
ClO2
O3
• Measure up to five atmospheric hazards concurrently
• Fully customizable to suit any application
• Rapidly switch from diffusion mode to the optional
integrated pump in the field
Wear yellow. Work safe.
Quickly switch from
diffusion to integral
pump option
Sensor for fifth toxic, PID,
or CO2 hazards
Replaceable integrated filter
• window enables user to
visually inspect filter
• provides superior dust
and water resistance
Four bright, wide-angled
alarm bars
Multiple charging
options available
Integral concussion-proof
enclosure
95 dB audible alarm
(typical)
Internal vibrating alarm for
high-noise areas
Raised buttons, easy to
use with gloves
Large, easy-to-read
display
Stainless steel
alligator clip
Optional datalogging
stores several months of
continuous data
AA alkaline or hot-swappable
rechargeable battery pack
options allow for battery
installation in the field
Instrument model differences
GasAlertMicro 5
GasAlertMicro 5 PID
GasAlertMicro 5 IR
Gases Detected
H2S, CO, O2, SO2, PH3, NH3, NO2, HCN,
Cl2, ClO2, O3 and combustibles (LEL)
VOCs (PID), H2S, CO, O2, SO2, PH3, NH3, NO2,
HCN, Cl2, ClO2, O3 and combustibles (LEL)
CO2 (IR), H2S, CO, O2, SO2, NH3, O3 and
combustibles (LEL)
Sensors
Plug-in, electrochemical cell (toxic and oxygen);
catalytic (LEL)
Plug-in, electrochemical cell (toxic and oxygen);
catalytic (LEL); Photoionization detector (PID) with
10.6 eV lamp for volatile organic compounds (VOCs)
Plug-in, electrochemical cell (toxic and oxygen);
catalytic (LEL); infrared (IR) for carbon dioxide
(CO2)
15 hours
15 hours
15 hours
15 hours
1
Typical battery life
AA Alkaline 20 hours
Rechargeable 20 hours
1
Based on the run time of a 5-gas instrument in diffusion mode at +68°F/+20°C, other instrument configurations or environmental conditions may increase/decrease the battery life of your instrument.
Industrial Applications
GasAlertMicro 5
Sensors
The GasAlertMicro 5 is available in three models: toxic/
electrochemical, PID (for VOCs) or IR (for CO2). For more
information about available sensor configurations, please
contact BW Technologies by Honeywell.
Industry or Application
Sources of Additional Hazards
Confined Space Entry
Various sources - industrial chemicals
Wastewater Plants
Cl2, NH3, ClO2 from treatment
Steel / Iron Production
NO2
Pulp and Paper
Cl2 from bleaching
Food and Beverage
NH3 from refrigerants, ice production
PH3 from fumigation
Construction
Confined space entry, trenching, and NO2 from
diesel exhaust
GasAlertMicro 5 PID
Electrochemical and catalytic bead sensors available for:
CO
O2
H2S
SO2
Cl2
ClO2
NH3
PH3
HCN
NO2
O3
Combustibles (LEL)
Industry or Application
Sources of VOC Hazards
Confined Space Entry
Respiration and aerobic bacterial decomposition
Hazmat / Homeland Security
Detect flammables not detected by LEL sensor
(diesel, gasoline vapor, turpentine, etc)
Industrial Hygiene and
Confined Space
Wide number of potential hazards (benzene, diesel,
ethanol, toluene, etc.) dependant on industry
Airlines (wing-tank entry)
Jet fuel not detectable by LEL sensor, PID required
Landfills
Decomposing organic matter, emission of chemical
compounds
Oil and Gas
By-products of refining processes
Chemical Plants
Number of potential hazards dependant on product
and process of manufacturing
GasAlertMicro 5 IR
Photoionization sensor available for volatile organic
compounds (VOCs) detection.
Infrared (IR) gold series sensors available for carbon
dioxide (CO2) detection.
Note: Due to board and sensor configuration GasAlertMicro 5
models are not interchangeable (i.e. a PID sensor cannot be
used in a IR configured unit).
Both the diffusion and pumped
configurations are compatible
with the MicroDock II
automated bump test and
calibration system
Industry or Application
Sources of CO2 Hazards
Confined Space Entry
Respiration and aerobic bacterial decomposition
Wineries and Breweries
By-product of yeast fermentation
Agriculture
Greenhouses, mushroom farms use CO2 to
enhance growth; also used to speed ripening of
fruits and vegetables, aerobic bacteria in manure
pits
Marine Fuel Transport /
Shipping and Shipyards
Used for fire suppression and inerting cargo holds
Oil Well Fracturing
Injected into mature wells for further oil extraction
Wastewater Treatment
Aerobic bacteria
Food Industry / Cold Storage
Solid CO2 (dry ice) used as a refrigerant and for
carbonation; CO2 used in packaging to extend
storage shelf life
Industrial and Chemical
Manufacturing
CO2 used in various processes
Landfills
Biodegradation (aerobic decomposition) of waste
Standard features of BW products:
Additional GasAlertMicro 5 Features:
• Continuous LCD shows real-time gas concentrations
• Integral motorized pump option for remote sampling
• Water-resistant
• Equipped with internal vibrating alarm for high noise areas
• Automatic calibration procedure; compatible with BW
MicroDock II automatic test and calibration station
• Two power options: AA alkaline or rechargeable hot-swappable
battery packs
• Full function self-test of sensor, battery status, circuit integrity
and audible/visual alarms on start up
• Multi-language support in English, French, German, Spanish and
Portuguese
• Bright wide-angled visual alarm bars
• Built-in concussion-proof boot
Options and Accessories
GasAlertMicro 5 Specifications
Size
5.7 x 2.9 x 1.5 in. / 14.5 x 7.4 x 3.8 cm
Weight
13.1 oz. / 370 g
Temperature
-4 to +122°F / -20 to +50°C
14 to +104°F / -10 to +40°C (PID)
Alarms
- Visual, vibrating, audible (95 dB)
- Low, High, STEL, TWA, OL (over limit)
Tests
Sensor integrity, circuitry, battery and audible/visual alarms
on activation, battery (continuous)
Pump
Optional; Sample from up to 66 ft. / 20 m
User options
Confidence beep
Integral pump and
battery charger
Set TWA method
Sensor on/off
O2 auto calibration on
start up
Latching alarms
Automatic backlight
Safe display mode
Sleep mode
Stealth mode
Adjust Clock
User-settable calibration
gas level
Set datalogger rate
Calibration due lockout
Passcode protection
Daily bump test
Correction factor library
(LEL, PID)
Language choices (five)
High resolution
Fast pump
Ratings
EMI/RFI: Complies with EMC Directive 89/336/EEC
IP 65/66
Certifications and
approvals
n
Class I, Div. 1, Gr. A, B, C, D
American Bureau of Shipping - Toxic & PID models
II 1 G
Ga Ex ia IIC T4*
X g II 2 G - IR model only
Ex d ia IIC T4*
Ga Ex ia IIC T4*
Ex d ia IIC T4* - IR model only
ATEX: X g
IECEx:
Belt holster
Collapsible sampling
probe
For a complete list of accessories, please contact BW Technologies.
Combustible gas
measurement (% LEL or
% by volume methane)
Set STEL interval
Confined space kit
Sensor Specifications
Measuring
Default
High Resolution
Gas
Range (ppm)
Resolution (ppm)
(ppm)
H2S
0-500
1.0
0.1
CO
0-999
1.0
N/A
TwinTox (H2S)
0-500
1.0
0.1
TwinTox (CO)
0-500
1.0
N/A
O2
0-30.0%
0.1%
N/A
SO2
0-150
1.0
0.1
PH3
0-5.0
1.0
0.1
NH3
0-100
1.0
0.1
NO2
0-99.9
1.0
0.1
HCN
0-30.0
1.0
0.1
Cl2
0-50.0
1.0
0.1
ClO2
0-1.0
0.1
0.01
O3
0-1.0
0.1
0.01
PID (VOCs)
0-1000
1
N/A
0-50,000
50
N/A
IR (CO2)
0-5.0% v/v
0.01%
N/A
Combustible
0-100% LEL
1%
N/A
gases
0-5.0% v/v
0.1%
Alarm set points for all sensors are user adjustable. Set point(s) are automatically displayed
during instrument start up.
Locally available from
*Temperature codes may vary as a function of the batteries installed. Please
see owner’s manual for a complete listing of compatible batteries and codes.
Warranty
Full two year warranty including sensors
(1 year NH3, Cl2, O3, ClO2 and PID lamp)
DUE TO ONGOING RESEARCH AND PRODUCT IMPROVEMENT, SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Corporate Headquarters
2840 - 2 Avenue S.E.
Calgary, AB, Canada T2A 7X9
Phone: +1.403.248.9226
Toll free: 1.800.663.4164
www.gasmonitors.com
USA
1.888.749.8878
Europe
+44 (0)1295.700.300
France
+33 (0) 442.98.17.70
Germany
49 (0) 2137.17.6522
info@gasmonitors.com
Middle East
S.E. Asia
China
Australia
+971.4.887.1766
+65.6580.3468
+86.10.6786.7305
+61.3.9464.2770
Latin America
Other Countries
+55.11.3475.1873
+1.403.248.9226
5612-15-EN
© 2010 Honeywell International Ltd. All Rights Reserved.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising