Dräger Pac® 7000
The Dräger Pac 7000 detector is an impressive instrument, offering a high level of
reliability and rapid warning against harmful concentrations of hydrogen sulfide,
oxygen, carbon monoxide, carbon dioxide,
sulfur dioxide, chlorine, hydrogen cyanide,
ammonia, nitrogen dioxide, nitrogen monoxide, phosphine, or organic vapors.
instrument can be replaced when clogged
with dirt or mud. Unique to Dräger, an
optional 5-year guaranty (filters and batteries need to be replaced at regular intervals) is available for the hydrogen sulfide,
oxygen and carbon monoxide monitors.
ST-1758-2005
Small and robust, ergonomic and intuitive, economic and powerful – the Dräger Pac 7000 is tailor-made for personal monitoring
at the workplace. Featuring the latest sensor technology, this
innovative single gas detector is equipped with a wide range of
functions and is suitable for many different applications in dayto-day industrial settings.
ST-2507-2005
Dräger Pac® 7000
NEW SENSOR TECHNOLOGY ‘EN
MINIATURE’
SMALL AND ROBUST
Dräger Pac 7000’s impact-resistant housing features a protective rubber coating
and is impervious to corrosive chemicals.
Dräger Pac 7000 meets the requirements
of IP 65 to ensure operation even when
projected with water. The protection
against electromagnetic effects has been
optimized. A crocodile clip made of stainless steel is used to fasten the instrument
securely to the wearer's clothing and can
be rotated to allow for individual preferences. The two alarm lights are located
on the corners of the instrument for 360°
visibility.
NO LIFETIME LIMITATION
The Dräger Pac 7000 features an unlimited
lifetime and has been designed to ensure
long-term operation. The battery and the
sensor can be easily replaced on-site and
without any additional equipment. Also,
the dust and water filter on the front of the
Utilizing long-life, state-of-the-art Dräger
XXS Sensor technology, the innovative
Dräger Pac 7000 boasts both speed and
reliability in regards to the measurement
results. The small size of the sensor supports the application-oriented design of
the instrument. Gas hazards that may
occur are displayed immediately thanks to
the very short diffusion paths inside the
instrument and the extremely quick electrochemical reaction times achieved by
the Dräger XXS Sensors.
SAFETY FIRST
Personnel safety is always the first priority.
The sensor is positioned inside the housing such as to allow gas to reach it from
above and from the front. This position
also minimizes the danger of a gas inlet
being accidentally covered by clothing.
ALARM / WARNING FUNCTION
Visual, vibrating and audible alarms are
Dräger Pac 7000
Increased functionality
and no lifetime limitation.
02 |
DRÄGER PAC® 7000
triggered when the two configurable
alarm thresholds are exceeded or in the
case of oxygen, when the levels fall below
the set value. For optimum perception, a
two-tone alarm is used. Furthermore,
Dräger Pac 7000 features an adjustable
TWA (time-weighted average) alarm and
STEL (short-term exposure level) alarm. A
warning is also given to indicate low battery levels or in the event of a device error.
inform the user when a function test is
required and, if after a set period time, the
function test has still not been performed;
the instrument will automatically shut off.
Additionally, when used with the Dräger
Bump Test Station, Dräger Pac 7000 can be
automatically calibrated after a failed bump
test. This ensures the proper functioning
of safety equipment.
CALIBRATION AND CONFIGURATION
DATA LOGGER
Dräger Pac 7000 features a data logger in
which all concentrations and events are
stored together with their respective
dates and times. The intervals are variable
and can be adjusted by the user. If a
one-minute interval is set, the data logger
has a capacity of about five days. The
stored data can be downloaded via a PC
that has Dräger Pac Vision or Dräger
CC-Vision software installed and edited
using, for example, Microsoft® EXCEL®
software. Alternatively, complete data
evaluation is possible when the Dräger
GasVision software is used.
Dräger Pac 7000 features an integrated
menu from which the bump test mode,
fresh air calibration and span calibration
can be selected. Access to fresh air and
span calibration can also be password
protected.
The instrument is equipped with an
infrared interface and can be linked to a
PC via the connecting cradle or the
Dräger E-Cal system. Dräger Pac Vision
or Dräger CC Vision software can be
installed on any PC to configure functions, as well as to calibrate and download
the stored data.
BUMP TEST MODE
DRÄGER PAC 7000 AT A GLANCE
Work safety in industrial settings relies on
gas measurement equipment that functions
properly. This is the reason why national
regulations require regular function or bump
tests to test the instrument’s functionality
using a known gas concentration. Dräger
Pac 7000 is designed to make bump
testing easier by automating the bump test
process when used in conjunction with
the Dräger Bump Test Station.
– High performance Dräger XXS Sensors
– Optional 5-year guaranty for hydrogen
sulfide, oxygen and carbon monoxide
monitors
– Automatic function test with Dräger
Bump Test Station
– Optional calibration function after a
failed function test
– Adjustable bump test interval
– Unlimited lifetime with simple battery,
sensor and filter replacement
– Integrated data logger
– Gas inflow from above and the front
– Adjustable TWA and STEL alarms
– Record of the peak concentration
The bump test mode is integrated within
the instrument and can be individually
configured to match specific safety regulations. For example, the instrument can
DRÄGER PAC® 7000
| 03
Dräger Pac 7000 H2S 1)
Dräger Pac 7000 H2S 2)
Dräger Pac 7000 H2S
Dräger Pac 7000 H2S
Low Concentrations
Dräger Pac 7000 O2 1)
Dräger Pac 7000 O2 2)
Dräger Pac 7000 O2
Dräger Pac 7000 CO1)
Dräger Pac 7000 CO 2)
Dräger Pac 7000 CO
Dräger Pac 7000 CO2
Dräger Pac 7000 SO2
Dräger Pac 7000 CI2
Dräger Pac 7000 HCN
Dräger Pac 7000 NH3
Dräger Pac 7000 NO2
Dräger Pac 7000 NO
Dräger Pac 7000 PH3
Dräger Pac 7000 OV
Dräger Pac 7000 OV-A
Measuring
Range
0 – 100 ppm
0 – 100 ppm
0 – 100 ppm
0 – 100 ppm
Default Alarm
Threshold A1/A2
10/20 ppm
10/20 ppm
by request
by request
0 – 25 Vol.-%
0 – 25 Vol.-%
0 – 25 Vol.-%
0 – 1999 ppm
0 – 1999 ppm
0 – 1999 ppm
0 – 5 Vol.-%
0 – 100 ppm
0 – 20 ppm
0 – 50 ppm
0 – 300 ppm
0 – 50 ppm
0 – 200 ppm
0 – 20 ppm
0 – 200 ppm
0 – 200 ppm
5 Year Guaranty (not including battery)
Dräger Pac 7000 5Y H2S 0 – 100 ppm
Dräger Pac 7000 5Y O2
0 – 25 Vol.-%
Dräger Pac 7000 5Y CO 0 – 1999 ppm
Resolution
1 ppm
1 ppm
1 ppm
0.1 ppm
Response
Time
15 sec.
15 sec.
15 sec.
15 sec.
Order
Code
83 18 674
83 18 971
83 18 677
83 21 004
19/23 Vol.-%
19.5/23.5 Vol.-%
by request
30/60 ppm
35/50 ppm
by request
by request
by request
by request
by request
by request
by request
by request
by request
by request
by request
0.1 Vol.-%
0.1 Vol.-%
0.1 Vol.-%
1 ppm
1 ppm
1 ppm
0.1 Vol.-%
1 ppm
0.05 ppm
0.1 ppm
1 ppm
0.1 ppm
1 ppm
0.01 ppm
0.5 ppm
1 ppm
10 sec.
10 sec.
10 sec.
15 sec.
15 sec.
15 sec.
30 sec.
15 sec.
30 sec.
15 sec.
20 sec.
15 sec.
15 sec.
10 sec.
100 sec.
100 sec.
83 18 675
83 18 972
83 18 678
83 18 673
83 18 970
83 18 676
83 18 975
83 18 976
83 18 978
83 18 973
83 18 979
83 18 977
83 21 263
83 18 974
83 21 006
83 21 007
by request
by request
by request
1 ppm
0.1 Vol.-%
1 ppm
15 sec.
10 sec.
15 sec.
83 21 032
83 21 033
83 21 031
Leather carrying case
45 43 822
Communication Accessories
Dräger Gas Vision
Dräger CC-Vision
Communication Module, complete with USB cable and Dräger Pac Vision software
83 14 034
64 08 515
83 18 587
Calibration Accessories
Calibration adapter
Dräger Pac Module for Dräger E-Cal calibration system
Dräger Bump Test Station for Dräger Pac 7000, not including gas cylinder
Dräger Bump Test Station for Dräger Pac 7000
Complete with one test gas cylinder 58L (gas and concentration variable)
Dräger Bump Test Station for Dräger Pac 7000
The station for an automatic bump test upon placing the Dräger Pac 7000 in the
cradle, not including gas cylinder
Dräger Bump Test Station for Dräger Pac 7000
The station for an automatic bump test upon placing the Dräger Pac 7000 in the
cradle, complete with one test gas cylinder 58L (gas and concentration variable)
Printer Set for Dräger Bump Test Station
Consisting of: Dräger Mobile Printer, single charger, rechargeable NiMH batteries,
USB connection cable, positioning aid, Dräger CC-Vision standard
Replacement Parts
Lithium battery
Water and dust filter
83 18 588
83 18 589
83 17 410
83 18 586
83 19 559
83 21 008
83 21 010
45 43 808
45 43 836
1) Default configuration Europe
2) Default configuration North America
Dräger Pac 7000
Small and robust personal monitor.
ST-5527-2005
Description
ST-5608-2004
ORDER INFORMATION
Dräger Pac 7000
Quick and reliable function tests.
DRÄGER PAC® 7000
TECHNICAL DATA
Dimensions (W x H x D)
Weight
Ambient conditions
84 x 64 x 25 mm; 3.3 x 2.5 x 1.0 in.
120 g; 3.8 oz.
Temperature1) -30 – 50 °C; -20 – 120 °F
Pressure 700 – 1300 hPa
Humidity 10 – 90 % r. h.
IP 65
Language-free LCD display, continuous indication of concentration, peak concentration,
TWA- and STEL-concentration, operating time, notice and alarm functions
5500 hours (O2 version: 2700 hours)
Two-tone-alarm, typical > 90 dB at a distance of 30 cm
Storage of concentration und events with date and time (120 hours @ 1 data set per minute)
Ingress protection
Display
Typical battery life
Acoustic alarm
Data logger
Approvals
CE-Sign (89/336/EEC, 94/9/EC)
ATEX
II 1 G EEx ia IIC, T4
I M 1 EEx ia I, T 4
UL
Class I, II, Div 1, Group A, B, C, D, E, F, G, Temp. Code T4
cUL
Class I, II, Div 1, Group A, B, C, D, E, F, G, Temp. Code T4
IECEx
EEx ia IIC, T4
Marine Equipment Directive 96/98/EC
Measurement Performance Certificate (acc. to ATEX) EN 45544 (CO, H2S), EN 50104 (02), EN 50271
1) Dräger Pac 7000 CO2 -20 – 40 °C (-4 – 104 °F), Dräger Pac 7000 HCN -20 – 50 °C (-4 – 122 °F), Dräger Pac 7000 PH3 -20 – 50 °C (-4 – 122 °F)
HEADQUARTERS:
Dräger Safety AG & Co. KGaA
Revalstrasse 1
23560 Lübeck, Germany
www.draeger.com
SUBSIDIARIES:
AUSTRALIA
Draeger Safety Pacific Pty. Ltd.
Axxess Corporate Park
Unit 99, 45 Gilby Road
Mt. Waverley. Vic 3149
Tel +61 3 92 65 50 00
Fax +61 3 92 65 50 95
P. R. CHINA
MEXICO
SINGAPORE
Beijing Fortune Draeger
Safety Equipment Co., Ltd.
Yu An Lu A 22, B Area
Beijing Tianzhu Airport
Industrial Zone
Houshayu Shunyi District
Beijing 101300
Tel +86 10 80 49 80 00
Fax +86 10 80 49 80-05
Draeger Safety S.A. de C.V.
Av. Peñuelas No. 5
Bodega No. 37
Fraccionamiento Industrial
San Pedrito
Querétaro, Qro México
Tel +52 442 246-1113
Fax +52 442 246-1114
Draeger Safety Asia Pte. Ltd.
67 Ayer Rajah Crescent # 06 03
139950 Singapore
Tel +65 68 72 92 88
Fax +65 67 73 20 33
CANADA
Draeger Canada Ltd.
7555 Danbro Crescent
Mississauga,
Ontario L5N 6P9
Tel +1 905 821 89 88
Fax +1 905 821 25 65
NETHERLANDS
FRANCE
Dräger Safety France SAS
3c route de la Fédération,
BP 80141
67025 Strasbourg Cedex 1
Tel +33 3 88 40 59 29
Fax +33 3 88 40 76 67
USA
Draeger Safety, Inc.
101 Technology Drive
Pittsburgh, PA 15275
Tel +1 412 787 83 83
Fax +1 412 787 22 07
Dräger Safety Nederland B.V.
Edisonstraat 53
2700 AH Zoetermeer
Tel +31 79 344 46 66
Fax +31 79 344 47 90
REP. OF SOUTH AFRICA
Dräger South Africa (Pty) Ltd.
P.O.Box 68601
Bryanston 2021
Tel +27 11 465 99 59
Fax +27 11 465 69 53
SPAIN
Draeger Safety Hispania S.A.
Calle Xaudaró 5
28034 Madrid
Tel +34 91 728 34 00
Fax +34 91 729 48 99
UNITED KINGDOM
Draeger Safety UK Ltd.
Blyth Riverside Business Park
Blyth, Northumberland
NE24 4RG
Tel +44 1670 352 891
Fax +44 1670 356 266
90 46 061 | 04.09-2 | Marketing Communications | UUU | PR | ED | Printed in Germany | Chlorine-free – environmentally compatible | Subject to modifications | © 2009 Dräger Safety AG & Co. KGaA
04 |
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising