Standpipe Meters and Hydrant Flushing Unit STM-E, STM-N, STM

Standpipe Meters and Hydrant Flushing Unit STM-E, STM-N, STM
Standpipe Meters and Hydrant Flushing Unit
STM-E, STM-N, STM-T, STW
The mobile tapping points for
taking water from hydrants
✘
✘
✘
✘
✘
Flow rate Qn 2.5 ... 25.
Weatherproof: designed for the tough conditions outdoors.
Indestructible: sturdy standpipe made of stainless steel.
Portable: connection-friendly ”light“ standpipe made of aluminium.
Steady: no compromises as to accuracy.
1
Standpipe Meters and Hydrant Flushing Unit
STM-E, STM-N, STM-T, STW
Graduated: four meter types
in five nominal sizes
Water on call
Where underground
hydrants are provided, the
water mains can be tapped
directly. Our standpipe meters
are ideally equipped for this
task. To ensure they can all be
connected without difficulty,
the technical details involved
have been carefully defined –
in Germany, for example, by
DIN 14 375.
More or less everywhere,
the statutory regulations demand that the water removed
(directly from the mains) be
metered and invoiced.
For this purpose, we offer
three types of meters, graded
by flow range. All of them
may be calibrated and
certified.
R A NT
HY D
STM-E, STM-N,
STM-T and STW
STM-E features
✘
All stainless steel hydrants
are fitted with a conical
strainer as a standard feature,
to protect the meter against
damage from coarse particles
in the water.
We also recommend
installing a non-return valve.
Depending on the stresses
involved, a choice is offered
of stainless steel or aluminium
standpipe meters. The latter
variant provides no fewer than
three advantages: it’s not only
lightweight and inexpensive,
the „soft“ material is also easier
on the underground hydrants.
✘
Meter with all the
OPTIMA’s excellent
characteristics.
Superlative response
sensitivity.
Continuous loads of
1.4 x Qn are no problem.
Standpipes and meters
plus fittings for water
extraction mounted ready
for use.
STM-N, STM-T
features
✘
✘
Meter also an OPTIMA.
Can be briefly
overloaded by 20 %.
Flange for totally secure
connection to the
standpipe.
Standpipes separately
available.
STW features
✘
✘
Lower
flow range:
Medium
flow range:
Upper
flow range:
STM-E
Multi-jet water meter
OPTIMA MNR-S
wet-dial
STM-N, STM-T
Multi-jet water meter
OPTIMA STM-N
wet-dial
STM-T
dry-dial
STW
Woltmann meter
STW
dry-dial
❑ Cold water up to 50 °C.
Qn 2.5
Qn 6
D 82
6.131.42
D 98
6.131.04
❑ Approval Class C.
❑ Display capacity
99 999 m3.
❑ Minimum scale value
0.05 l.
❑ Cold water up to 50 °C.
Qn 15 und Qn 25
❑ Cold water up to 50 °C.
Qn 6 und Qn 10
D 98
6.131.04
D 81
6.132.05
❑ Approval Class B.
❑ Display capacity
99 999 m3.
❑ Minimum scale value
0.05 l.
D 98
6.131.05
❑ Approval Class B.
❑ Display capacity
99 999 m3.
❑ Minimum scale value
0.05 l.
2
Meter almost
indestructible.
Woltmann metering
principle with vertical
rotor.
Flange connection.
Standpipes separately
available.
Metering accuracy
✘
Comfortably conforms
to ISO 4064
for cold water.
✘
Choice of materials:
aluminium or stainless
steel.
Connection according
to DIN.
Other connections
on request.
Standpipes
✘
✘
The technical data
Qn 2.5 Qn 6
EEC standards require head loss
not to exceed
0.25 bar at Q n
1.0 bar at Qmax
Pressure loss in bar
1.0
0.1
0.01
0.1 0.2 0.3 0.5
Flow rate in m3/h
1
2 3 4 5
10
20 30 40 50
100
Standpipe meter
STM-E
Type
A
C
Hydrant flushing unit
Type
D
F
Meter size / nominal flow rate
Qn
m3/h
2.5
6
—
—
Nominal size
DN
mm
20
25
—
—
DN
inches
3/4
1
—
—
............................................................................................................................................................................................................................................................................................................................
Meter connection thread
ISO 228/1
inches
G1B
G 1 1/4 B
—
—
............................................................................................................................................................................................................................................................................................................................
OPTIMA
Maximum flow rate
Qmax
m3/h
7
12
—
—
Transitional flow rate
Qt
l/h
120
280
—
—
Minimum flow rate
Qmin
l/h
20
40
—
—
............................................................................................................................................................................................................................................................................................................................
Continuous load
m3/h
7
12
—
—
Temperature
Tmax
°C
50
50
50
50
Pressure rating
PN
16
16
16
16
Flow capacity
at 1 bar pressure loss
m3/h
>5
> 12
—
—
............................................................................................................................................................................................................................................................................................................................
Weight
Assembled
Aluminium
kg
8.0
11.0
7.0
6.0
Stainless steel
kg
14.5
16.5
12.5
—
Standpipe meter STM-E
Type A Q n 2.5
2 outlet valves
with hose connections
Type C Qn 6
1 outlet valve
with hose connection,
1 valve with C-coupling
Type F
2 valves
with C-couplings
Hydrant flushing unit
Type D
1 valve
with C-coupling
Stainless steel D 76
Aluminium D 72
Qn 2.5 940
Qn 6 1000
850
3
970
Qn 6
DN 50
Qn 10
Pressure loss in bar
Pressure loss in bar
DN 65
1.0
1.0
0.1
0.01
0.1 0.2 0.3 0.5
Flow rate in m3/h
1
2 3 4 5
10
20 30 40 50
0.1
0.01
1
2
4 5
Flow rate in m3/h
100
10
20
40 50
100
200
Standpipe meter
Meter size / nominal flow rate
Nominal size
500
1000
STM-N, STM-T
STW
Qn
m3/h
6
10
15
25
DN
mm
25
40
50
65
DN
inches
1
1 1/2
2
2 1/2
............................................................................................................................................................................................................................................................................................................................
Meter connection thread
ISO 228/1
inches
G 1 1/4 B
G2B
G2B
G 2 1/2 B
............................................................................................................................................................................................................................................................................................................................
OPTIMA
Woltmann
Maximum flow rate
Qmax
m3/h
12
20
30
75
Transitional flow rate
Qt
l/h
480
800
3 000
6 000
Minimum flow rate
Qmin
l/h
40
60
400
500
............................................................................................................................................................................................................................................................................................................................
Continuous load
m3/h
12
20
15
50
Temperature
Tmax
°C
50
50
50
50
Pressure rating
PN
16
16
16
16
Flow capacity
at 0.1 bar pressure loss
m3/h
—
—
18
54
at 1 bar pressure loss
m3/h
12
20
—
—
............................................................................................................................................................................................................................................................................................................................
Weight
Standpipe meter
kg
3.5
5.5
4
5
Standpipe according to DIN 14375
Aluminium
kg
4.0
4.0
4.0
4.0
Stainless steel
kg
10.0
10.0
10.0
10.0
Standpipe meter STW
Standpipe meter STM-N, STM-T
D
D
❏
❏
❏
❏
Accessory mounting
example:
Fixed coupling
with female thread.
Also available:
Cutoff valve.
Fixed coupling
with male thread.
Adapters
for Qn 6/DN 25.
330
Accessory mounting
example:
❏ Cutoff valve.
❏ Fixed coupling
with male thread.
Also available:
❏ Fixed coupling
with female thread.
Standard version 690
Short version
400
Standpipe according to DIN 14 375
for underground hydrant
according to DIN 3221
and underground field hydrant
according to DIN 19 6562.
Other connections
on request.
4
The order numbers
Standpipe meter
STM-E
Multi-jet water meter OPTIMA MNR-S, certified to Class B.
With standpipe, assembled
Standpipe meter
STM-E
STM-E
STM-E
STM-E
Type
A
A
C
C
Flow rate
Qn m3/h
2.5
2.5
6
6
Nominal size
DN mm
20
20
25
25
...........................................................................................................................................................................................................................................
Standpipe
Handle
Aluminium
Stainless steel
Aluminium Stainless steel
Pipe
Aluminium
Stainless steel
Aluminium Stainless steel
Foot
Aluminium
Stainless steel
Aluminium Stainless steel
Clutch
Aluminium
Brass
Aluminium
Brass
...........................................................................................................................................................................................................................................
Acc. to DIN 14375
Order No.
1168424
0652962
1168440
0652970
Hydrant flushing unit
With standpipe, assembled,
without meter
Standpipe meter
STM-N / STM-T / STW
Type
D
D
F
F
...........................................................................................................................................................................................................................................
Standpipe
Valve
Brass
Brass
Aluminium
Aluminium
Handle
Aluminium Stainless steel
Aluminium Stainless steel
Pipe
Aluminium Stainless steel
Aluminium Stainless steel
Foot
Aluminium Stainless steel
Aluminium Stainless steel
Clutch
Aluminium
Brass
Aluminium
Brass
...........................................................................................................................................................................................................................................
Acc. to DIN 14375
Order No.
1168459
0652989
1168467
0652997
Multi-jet water meter OPTIMA 2002 STM-N and STM-T, certified to Class B.
Woltmann meter STW, certified to Class B.
without standpipe
Standpipe meter
STM-N
STM-N
STM-T
STM-T
STW
STW
Flow rate
Qn m3/h
6
10
6
10
15
25
Nominal size
DN mm
25
40
25
40
50
65
...........................................................................................................................................................................................................................................
Order No.
0647853
0647962
0647942
0647969
1104655
1104809
Standpipe
According to DIN 14375
For underground hydrant according to DIN 3221
and underground field hydrant according to DIN 19 652.
Standpipe
Handle
Aluminium Stainless steel
Pipe
Aluminium Stainless steel
Foot
Aluminium Stainless steel
Clutch
Aluminium
Brass
............................................................................................................................................................................................................................................
Acc. to DIN 14375
Order No.
0649902
0643920
............................................................................................................................................................................................................................................
Short version
L 400 mm
Order No.
0652954
0652709
R: on request
5
The order numbers
for accessories
Accessories
Description
Dimensions
mm / inches
Order No.
...........................................................................................................................................................................................................................................
Non-return valve
Plastic
DN 25, 40, 50
2
0501385
for standpipe according to DIN 14375
DN 65
2 1/2
0517236
...........................................................................................................................................................................................................................................
Cutoff valve
Brass
DN 25
G 1 1/4 l
0517124
DN 40, 50
G
2 l
0509129
DN 65
G 2 1/2 l
0524362
...........................................................................................................................................................................................................................................
Fixed coupling for valve
C
DIN 86204
Brass
DN 50
G
2 A
1198331
C 1 DIN 14317
Aluminium
DN 50
G
2 A
0508043
B 1 DIN 14318
Brass
DN 65
G 2 1/2 A
0601423
Fixed coupling for meters
B
DIN 86204
Brass
DN 50
G
2 I
0508059
B
DIN 86205
Brass
DN 65
G 2 1/2 I
0508066
B
STORZ 75
Aluminium
DN 50
G
2 l
1084964
B
DIN 14388
Aluminium
DN 65
G 2 1/2 l
1003077
...........................................................................................................................................................................................................................................
Adapter
Brass
Cutoff valve DN 25 on fixed coupling C 1
G 1 1/4
A–G
2 l
0517206
STM-N Qn 6 / DN 25 on fixed coupling C
G 1 1/4
I–G
2 A
0510941
...........................................................................................................................................................................................................................................
Adapter
Brass
DN 80
G
3 A
1008184
Irrigation meter WP-T-D
on standpipe
Spare part
...........................................................................................................................................................................................................................................
Conical strainer
Stainless steel
D 64.5
0510027
for standpipe according to DIN 14375
in stainless steel
Snap ring (to hold strainer)
Stainless steel
0513601
ELSTER Messtechnik GmbH
Otto-Hahn-Strasse 25
D-68623 Lampertheim
Phone +49 (0) 62 06 / 9 33-0
Telefax +49 (0) 62 06 / 9 33-100
messtechnik@de.elster.com
www.elstermesstechnik.com
L 04.10 e / 05.03
Changes may occur
without notice
6