SOFTWARE RELEASE NOTES

SOFTWARE RELEASE NOTES
SOFTWARE RELEASE NOTES
for
Intermec Terminal Emulator
Version 1.42
1.
VERSION INFORMATION .............................................................................................................. 1
2.
INSTALLATION NOTES ................................................................................................................. 2
SMARTSYSTEMS INSTALL ........................................................................................................................... 3
CAB FILE OR SELF-EXTRACTING INSTALL ................................................................................................... 3
LICENSING .................................................................................................................................................. 3
3.
NEW FEATURES ............................................................................................................................... 5
4.
DEVICES NO LONGER SUPPORTED .......................................................................................... 5
5.
ISSUES FIXED IN THIS VERSION ................................................................................................ 5
6.
KNOWN ISSUES ................................................................................................................................ 5
KEYBOARDS ............................................................................................................................................... 5
RPC............................................................................................................................................................ 5
SCANNING .................................................................................................................................................. 5
SSH ............................................................................................................................................................ 6
UDP+ ......................................................................................................................................................... 6
OUT OF RANGE MONITOR ............................................................................................................................ 6
BLUE LIGHT ................................................................................................................................................ 6
1. Version Information
This release of Intermec Terminal Emulator (ITE) operates on 70 Series, CK3A, CK3B,
CK3R, CK3X, CN50, CN51, CN3, CS40 and CN4 Windows mobile computers.
Support has also been added for the CV61 Windows 7 and WinXP computers as well as
the CV41 WinCE and CV41 WES computers.
Intermec Terminal Emulator is the next generation of Intermec’s popular terminal
emulation client (previously known as TE 2000) which connects Intermec computers to
host applications using 5250, 3270 and VT/ANSI emulation. ITE V1.42 is built on years
of industry experience and expertise in TE 2000 and has been tested for optimal
performance on the Intermec terminals in emulation environments such as warehouses.
ITE supports 4 simultaneous host sessions, security, and complete data collection with
Intermec scanning and RFID technologies. .
Please reference the ITE Programmer’s reference manual for additional information on
features and use of ITE.
ITE_Release_Notes_V1.42.01.0203
Intermec Technologies
Page 1 of 6
Below is the minimum version of OS, SSPB and IVA that should be used with this
version of ITE. The ITE application was also tested against the SmartSystems foundation
version 4.80.01.76.
.
Device
Operating System
CK3B Windows Mobile 6.1
Operating
System
Version
3.45.26.0031
SSPB
6.20.33.0480
IVA
5.04.70.2822
CN3
Windows Mobile 5.0
3.26.15.0170
7.00.36.0592
5.03.59.2363
CN3
Windows Mobile 6.1
4.30.31.0014
7.00.36.0548
5.06.72.3191
CN4
Windows Mobile 6.1
4.41.32.0018
7.00.36.0555
5.06.72.3198
Operating
System
Version
1.50.19.0013
1.61.16.0001
1.61.15.0063
2.10.00.0656
Smart Systems
reference client
4.60.00.0066
4.00.00.0178
3.48.07.0669
4.03.11.0591
Intermec
Settings
5.80.00.0112
5.70.00.0080
5.52.10.1197
5.70.00.0080
1.10.02.0011
1.00.00.0085
1.00.00.0153
1.00.00.0153
1.50.19.0013
1.50.19.0013
4.10.00.0358
4.70.00.0152
4.10.00.0260
4.10.00.0260
4.60.00.0066
4.60.00.0066
5.70.00.0191
5.90.00.0191
5.70.00.0258
5.70.00.0258
5.80.00.0112
5.80.00.0112
Device
70 Series
CS40
CN50
CN50
CN51
CV41
CV41
CV61
CV61
CK3X
CK3R
Operating
System
WM6.5
WM6.5
WM6.1
WM6.5
WM6.5
Windows CE6.0
WES
Windows7
WinXP
WM 6.5
WM 6.5
2. Installation Notes
:
ITE_Release_Notes_V1.42.01.0203
Intermec Technologies
Page 2 of 6
SmartSystems Install
This method is a good option when installing ITE on multiple computers. This option
requires a PC running SmartSystems Foundation. You may download a free version of
SmartSystems Foundation from Intermec’s web site at:
-
http://www.intermec.com/products/smrtsysfoundation/index.aspx
Download the ITE SmartSystem bundle from the Intermec downloads site to your PC.
Double-click on the bundle to install and after completing ITE will appear in the
SmartSystems Console. You may then use any of the supported installation methods
including dragging the ITE client and dropping it onto the target computer.
Cab file or self-extracting install
Download the ITE cab file or self-extracting file for the appropriate device from the
Intermec downloads web site http://www.intermec.com/products/ite/index.aspx.
ITE_WM_VGA_WVGA.cab for the 70 series computers or CN51 computer
ITE_Other_WM_ARMV4I for the CN3, CN4, CN50, CS40 or CK3 computers
ITE_CV41_CE60_x86 for the CV41 CE computers
ITEXP7Setup for the CV61 Windows7, CV61 WinXP and CV41 WES computers
The ITE file can then be deployed to the device by SD Card, active sync or other device
management software. See the user manual of the device you want to install on for the
location of where to place the cab file if you want it to automatically install.
After ITE is installed on the device it can be found in the Program Files\Intermec\ITE
folder.
For the CV41 CE after ITE has finished its installation you will need to manually reboot
the device. This can be done by executing reboot /w. Any configuration files that ITE
uses need to be placed into the system\ITEdata folder.
For the CV41 and CV61 computers by default the ITE application will not auto start
when it is installed. To change this behavior use Intermec Settings to open the
Applications|Intermec Terminal Emulation|folder and then change the setting of no AutoStart to enabled.
Note: If you put the incorrect cab file on to your computer then the ITE toolbar graphics
will not be displayed correctly.
Licensing
ITE_Release_Notes_V1.42.01.0203
Intermec Technologies
Page 3 of 6
If ITE was not purchased pre-installed on your Intermec handheld, ITE will require
activation to operate with full functionally beyond the evaluation period.

If this version of ITE was delivered pre-installed on your Intermec mobile
computer, then no activation is required.
The ITE V1.42 application has license build date of June 12, 2013.
ITE will run in a Demo mode for 60 days if your device does not contain a proper factory
license or activation license. Demo mode allows you to operate the device for 60 days in
“full feature”. After 60 days, the device will move to nag mode.
Licenses are available for purchase through your Intermec representative or Intermec
Reseller.
ITE_Release_Notes_V1.42.01.0203
Intermec Technologies
Page 4 of 6
3. New Features
None
4. Devices no longer supported




CV30 WM5
CV30 CE
CK60 WM5
CK60 CE
5. Issues Fixed in this Version




CPR131206-000076 ITE reading barcodes only via wedge mode and not API mode.
CPR131204-000143 With a Japanese OS ITE is failing to correctly display Katakana
and Hiragana characters
Fixed ITE version number in SmartSystems device properties
Registry setting for HKCU\ControlPanel\SIP\SuggWords was incorrectly set 1 reset
to 0.
6. Known Issues
Keyboards


Hitting the control 1-5 keys does not send data to the host. The work around is to use
the SIP to send these control values to the host.
The CV61 will require you to install the SR1305200-KEY_CV61_ALL in order to
get the ITE emulation key values from the keyboard.
RPC



Windows dialog boxes are not sent from the ITE application to the attached client.
If an attached client severs its ties to the ITE application rather than closing its
connection, then performance of the ITE application will be vastly affected
(approximately five second delays for all ensuing screen updates).
If you use SendKeys function then all data will be sent to the ITE application as
uppercase characters. There is no method to send lowercase characters.
Scanning


The encode barcodes for Next screen, control X and Control 5 no longer work.
When parmsbysession is enabled and you scan a computer identics 2 of 5 barcode
then an = character is added to the beginning of the barcode as the barcode type
ITE_Release_Notes_V1.42.01.0203
Intermec Technologies
Page 5 of 6


character. The actual value is supposed to be a Z character and the = is supposed to
be for a straight 2 of 5 barcode.
When parmsbysession enabled EAN13 barcodes will not decode.
The scanner fails to read data in to windows dialog boxes.
SSH

If the user attempts to make an SSH connection and that connection fails for several
hours (3-4) then the ITE toolbar will fail to be displayed or start to flicker. Also a
scanner error can get displayed.
UDP+

Host fallback option using multiple sessions will sometimes cause the ITE application
to crash. At this time it is best to not allow host fall backs for more than a single
session.
Out of range monitor


The out of range monitor dialog box is not shown on a CV61 running Windows 7.
Only the text is displayed.
On a CV61 Windows XP OS when the device goes out of range to the point where it
loses its IP address the connection to the host is reset and the out of range monitor
dialog is not shown.
Blue light

On the CV61 with the Windows 7 operating system the blue light is not getting
changed to indicate that ITE is making a valid connection to the host. Also asset
messages about ITE’s status are not getting sent to the SmartSystems console. This
will be corrected in a future build of the SSRefclient for the CV61.
ITE_Release_Notes_V1.42.01.0203
Intermec Technologies
Page 6 of 6
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising