Model: 6EOD 60 Hz 4.5EFOD 50 Hz Marine Generator Set

Model: 6EOD 60 Hz 4.5EFOD 50 Hz Marine Generator Set
Model: 6EOD
4.5EFOD
60 Hz
50 Hz
1-Phase Diesel
Marine Generator Set
Engine Features
D Diesel fueled
D Certified by the Environmental Protection Agency
D
D
D
D
D
(EPA) to conform to Tier 4 emissions regulations
Three cylinder
Four cycle
Closed cooling system
Heat exchanger
Lifting eyes
Generator Features
Generator Weights and Dimensions
Without
Sound Shield
Weight, kg (lb.)
Wet
Dry
165
163
Length, mm (in.)
Width, mm (in.)
Height, mm (in.)
717 (28.24)
419 (16.48)
545 (21.44)
(365)
(360)
With
Sound Shield
199
197
(440)
(435)
737 (29.00)
503 (19.80)
564 (22.22)
Generator Ratings
Model Series
6EOD
4.5EFOD
D
D
D
D
D
D
ADC 2100 Advanced Digital Control
Features
D
D
D
D
D
D
D
D
Voltage
Hz
25_C (77_F)
Amps
25_C (77_F)
kW/kVA
Ph
120
60
50.0
6/6
1
120/240
60
50.0/25.0
6/6
1
115/230
50
34.8/17.4
4/4
1
230
50
17.4
4/4
1
240
50
16.7
4/4
1
RATINGS: Marine continuous ratings per ISO 3046, ISO 8528-1, and Kohler ISO rating
guideline 2.14. Obtain technical information bulletin (TIB-101) on ratings guidelines for complete
ratings definitions.
Availability is subject to change without notice. Kohler Co. reserves the right to change the design or
specifications without notice and without any obligation or liability whatsoever. Contact your local
Kohler generator distributor for availability.
10% Overload Capacity One Hour in Twelve Hours
G2-109 (6EOD) 11/10a
Remote start 12-pin connector
Class H insulation
Multivoltage adjustability
60/50 Hz capability
Voltage regulation of ±1.5%
Radio suppression
Designed for today’s most sophisticated electronics
Easy to read alpha-numeric display
Compact, integrally mounted control
Potted boards/sealed connectors for maximum
corrosion protection
SAE J-1939 CANbus output
Remote monitoring of up to 13 fault conditions
Membrane keypad for configuration and
adjustment
Programmed crank cycle
Optional Accessories
D
D
D
D
Sound shield
Remote digital gauge
Siphon break
Circuit breakers
Application Data
Engine
Engine Specifications
Type
Operation Requirements
60 Hz
50 Hz
4 cycle, naturally aspirated
Cylinder, quantity
3
0.762 (46.5)
Bore and stroke, mm (in.)
67 x 72 (2.64 x 2.83)
Combustion system
Engine combustion air requirements,
L/min. (cfm)
Engine/generator cooling requirements,
L/min. (cfm)
Displacement, L (cu. in.)
Compression ratio
Air Requirements
23.5:1
Fuel Consumption
60 Hz
50 Hz
595 (21)
481 (17)
5097 (180)
4247 (150)
60 Hz
50 Hz
Diesel, Lph (gph) at % load
Indirect injection
100%
2.2 (0.59)
1.9 (0.50)
Rated rpm
1800
1500
75%
1.7 (0.45)
1.5 (0.39)
Max. power at rated rpm, HP
10.19
8.18
50%
1.2 (0.32)
1.1 (0.28)
Cast iron
25%
0.7 (0.19)
0.6 (0.17)
Cast iron
Note: The fuel consumption of the 60 Hz model is based on 6EOD
and the fuel consumption of the 50 Hz model is based on 4.5EFOD.
Cylinder block material
Cylinder head material
Piston rings: quantity, type
Crankshaft material
Connecting rod material
Governor, type
2 compression/1 oil
Forged steel
Engine Features
Cast iron
All speed, mechanical
D Low oil pressure shutdown
Frequency regulation, mechanical
governor
No load to full load (droop) . . . . . .
Steady state . . . . . . . . . . . . . . . . . . .
D High engine temperature shutdown
5%
±0.8%
D Belt guard
D Disposable oil filter
Engine Electrical
Engine Electrical System
D Oil drain valve and hose
60 Hz
50 Hz
Battery, voltage
Battery, charging
Battery, minimum recommendation
Starter motor
12 volt
500 CCA, 100 amp hr.
0.8 kW Bendixautomotive type
60 Hz
N/A
Heat exchanger type
2.5 in. dia. x 3 pass
cupronickel
Seawater pump type
Gear-driven,
10-blade impeller
D Static excited, rotating field design permits power to be obtained from
stationary leads.
D Rotors are dynamically balanced to minimize vibration.
D Copper windings ensure minimal heat buildup. Insulation meets
NEMA standards for class H insulation.
D Direct connected to the engine, the generator has sealed precision
ball bearings with a precision-machined steel sleeve in the end
bracket to prevent shaft misalignment and extend bearing life.
D Mounted on a drip-proof tray.
Heat rejected to cooling water at rated
kW, wet exhaust, kW (Btu/min.)
8.5 (481)
7.0 (398)
Engine water pump flow, Lpm (gpm)
24.7 (6.5)
20.6 (5.4)
12 (3.2)
10 (2.6)
60 Hz
50 Hz
Seawater pump flow, Lpm (gpm)
Generator Features
D Rotor and stator are vacuum impregnated and coated with high-bond
epoxy varnish. Varnish helps prevent corrosion in high-humidity
areas.
50 Hz
Capacity, L (qt.), approx.
D Full flow cooling system (thermostat bypass)
D Glow plug circuit for cold starting
18-amp alternator
Cooling
Cooling System
D One-side serviceability of fuel system, lubrication system, seawater
pump, and air cleaner
D Equipped with a four-lead reconnectable stator.
Fuel
Fuel System
Fuel pump
Mechanical
Maximum recommended fuel lift, m (ft.)
0.9 (3.0)
Lubrication
Lubricating System
Oil pan capacity with filter, L (qt.)
Oil pump type
60 Hz
50 Hz
3.05 (3.2)
Pressure, trochoid pump
G2-109 (6EOD) 11/10a
Application Data
ADC 2100 Control Features
Accessories
Sound Shield
Provides for highly effective silencing, ease of access for
engine/generator servicing, low maintenance, excellent
durability, and safety. The sound shield’s customer
connection panel includes connections for the following:
D LED display:
d Runtime hours
d Crank cycle status
d Diagnostics/fault codes/data
D Keypad
d Secure access, password protected
d Voltage, gain, and speed adjustment
d Controller configuration (system voltage, phase, and
frequency settings, battery voltage, and generator set
model)
D Master control switch: run/off-reset/auto (engine start)
D Remote two-wire start/stop capability
D Potted electronics and sealed connections
D Voltage regulation ±1.5%
D Cyclic cranking: 15 seconds on, 15 seconds off
(3 cycles)
D Faults with shutdown:
d High engine temperature
d Low oil pressure
d Loss of coolant
d Overcrank safety
d Overspeed
d Over/under voltage
d Over/under frequency
d Auxiliary fault
D Faults with warning:
d Low battery voltage
d High battery voltage
D Power requirements:
d 12 VDC with fuse protection
d 200 mA @ 12VDC/100 mA @ 24 VDC
d
d
d
d
d
d
d
d
Battery (positive and negative)
Equipment ground
Fuel inlet and return
Seawater inlet
Water-cooled exhaust outlet
Oil drain
Customer load lead access
Customer interface
Siphon Break
Mandatory kit on generators installed below the waterline.
Prevents the siphoning of flotation water into the engine.
Line Circuit Breakers
Protect the generator from extreme overload.
Preheat Kit
Provides improved starting in cold climates.
Ship-to-Shore Switch
Allows immediate switching to Kohlerr generator set
power or shore power protecting the electrical system
from the possibility of simultaneous connection of both
power sources.
Remote Digital Gauge
Allows starting/stopping from a location remote from the
generator set. Standard 76.2 mm (3 in.) dia. hole required
for mounting.
Oil Pressure Sender Kit
Provides sender necessary to make digital gauge
functional.
Remote Connection/Extension Harness
Provides wiring between the remote digital gauge and the
ADC connector. Extension limited to a total of four kits
and 23 m (75 ft.). Available in 4.6 m (15 ft.) and 7.6 m
(25 ft.) lengths.
12-Inch Remote Wiring Harness
Equipped with a 12-pin connector on one end that
connects to the standard customer interface connector.
Equipped on the other end with leads for connection to
customer-supplied wiring.
G2-109 (6EOD) 11/10a
KOHLER CO., Kohler, Wisconsin 53044 USA
Phone 920-457-4441, Fax 920-459-1646
For the nearest sales and service outlet in the
US and Canada, phone 1-800-544-2444
KohlerPower.com
ADV-7093-D
DISTRIBUTED BY:
NOTE: Dimensions in [ ] are inch equivalents.
NOTE: This drawing is provided for reference only and is not
intended for installation planning. Contact your local
distributor for more detailed information.
E
2006 and 2010 by Kohler Co. All rights reserved.
G2-109 (6EOD) 11/10a