PF3000 and PF3000 Pro – Application Rate Mode - Menu Tree for Hiniker 8100 and 8150 controllers – March 2002
Menu Key
FIELD
LOAD
SHOW MAP
CAL
SETUP
DIAG
OPTIONS
Press Menu Key to switch between Main Menu keys
FIELD
[Create or change field and name field
functions. Active configuration for
field displayed.]
LOAD
SHOW MAP
[Create or change load and
name load functions.]
[Splits screen and shows On
Screen Map on left side.
Press HIDE MAP key to
return to full screen. ]
OPTIONS
MARKS
LIGHTBAR
NAVIGATE
BOUNDARY
GRID
VIEW
CONFIG
[Set active configuration and active
tgt prescription file.]
ACTIVE
ON/OFF
EDIT
TGT FILE
[Select and accept new tgt
prescription file.]
SET A
Press at
beginning of
guidance
reference
pass.
VIEW
INFO
SET B
RESET
Press at end
of guidance
reference
pass. When
using curve
pattern,
press at end
of every
pass.
Press to
reset
guidance
and area
points to
start a new
field.
PAUSE
Press to
pause
guidance
when filling
applicator.
Drive back
to swath and
press
RESUME
key.
ADD/STRT
CLR/STOP
AREA PT
Used for
Headlands.
See Lightbar
Manual.
Used for
Headlands.
See Lightbar
Manual.
Press at every
corner of field to
calculate field
area. Must have
“Field Area”
displayed on
main screen to
see area.
[Screen displays field, product, units/ac and default
rate stored in tgt file.]
Revision 2
1 of 3
P.N. 2002831-21
PF3000 and PF3000 Pro – Application Rate Mode - Menu Tree for Hiniker 8100 and 8150 controllers – March 2002
Menu Key
FIELD
LOAD
SHOW MAP
CAL
SETUP
DIAG
OPTIONS
Press Menu Key to switch between Main Menu keys
CAL
AREA
SETUP
APP RATE
CONFIG
DISTANCE
MARKS
[Radar calibration screen]
Settings
Logging device
Logging interval
Log file
[Screen Displays all product/controller
configurations]
EDIT
SETTINGS
CARD
CREATE
NEW
DELETE
[To erase files,
press SHOW
ALL FILES key,
select file, press
FILE OPTIONS
key and press
ERASE FILE
key.]
LOAD
DIAG
CONSOLE
Settings
Operating mode
Units of Measure
Month/Day/Year
Time
Serial number
Box cal
Voltage cal
GPS check sum
Field marker input
Display brightness
Settings
Controller Make
Controller Model
Product
Units
Ground Speed Source
App Distance From GPS
Full Swath
Tgt Units:Contrler Units
Target Rate Increment
Actual Rate Scale Factor
ADVANCED
SETTINGS
Settings
Target rate outside field
Controller time delay
Actual rate units
Log actual rate
Revision 2
MEMORY
GPS
[Clear data in
loads or erase
all fields
functions]
SYSTEM
SENSORS
GPS
RAW
NMEA
Selections
NMEA MESSAGE
GPS/PORT CONFIGURATION
BEACON DIFFERENTIAL
SATELLITE DIFFERENTIAL
LIGHTBAR
GUIDANCE
Guidance Screen Settings
Pattern
Headland Type
Look-Ahead
Display Mode
Swath Direction
Swath Width
Antenna Offset
Pass Skips
Units Displayed
Contour Log Interval
CONTRLER
SETTINGS
MAP
Satellite Differential Screen Settings
Differential source = BEACON or WAAS or SATELLITE
Differential provider
Satellite frequency
Satellite baud rate
Provider user code
Omnistar code
Subscription expiration
Age of differential
Settings
Flowmtr pulses/gal or unit
Act rate:Flowmeter ratio
Area count
2 of 3
P.N. 2002831-21
PF3000 and PF3000 Pro – Quick Reference Setup Instructions for all Hiniker 8100 and 8150 models – March 2002
Note: These instructions pertain to PF firmware versions 4.00 or
higher.
3
Settings for Hinker 8100/8150 Controllers
1.
2.
Press SETUP key. Press APP RATE CONFIG key. Press CREATE
NEW key. Set the following:
Controller Make: Set to FLOWMETER.
Controller Model: Set to LIQUID or GRANULAR.
Product: Press EDIT key. You can select an existing product and press
ACCEPT key or create a new product by pressing CREATE NEW key.
Press EDIT NAME key and enter name of product. Use Left or Right
Arrow keys to select a character. Use Up or Down Arrow key to change
the character. Set every character and press ACCEPT key twice.
Units: Usually set to GALLONS. Set to Units/Acre of application.
Ground Speed Sensor: Set to GPS. Can not use WHEEL, TRACK or
RADAR because #pulses/100 ft for Hiniker is too low for PF.
App Distance From GPS: Ignore this setting.
Full Swath: Set to width of applicator.
Tgt Units:Contrler Units: Ignore this setting.
Target Rate Increment: Ignore this setting.
Actual Rate Scale Factor: Set to 1.000.
Press CONTRLER SETTINGS key. Set the following:
Flowmtr pulses/gal or unit: This setting must match the pulses per gallon
on the decal of the Hiniker flow meter. If applying anhydrous ammonia
this setting must match the pulses per pound on the decal of the Hiniker
flow meter (Pounds of Actual N).
Act rate:Flowmeter ratio: If want to record the carrier gallons/ac set to
1.000:1.
Exit back to main screen.
a)Press FIELD key twice.
b)Select appropriate field and press VIEW CONFIG key.
c)Select appropriate product/controller configuration and press ACTIVE
ON/OFF key to check it as active.(All other configs must be unchecked
first).
d)Press ACCEPT key to accept field.
How to change a setting
Press the EDIT key and use the Up or Down Arrow keys to change the setting.
For most settings, you can set each digit by pressing the Left or Right Arrow
key to select the digit. Use the Up or Down Arrow keys to set the digit.
Area Counting
The area count switch (located on bottom right of front panel) must be up and
Hiniker must start applying for area to be on.
If want to record product units/ac use following formula:
# product units
1 gallon of carrier = setting
.08 pint Treflan
Example: 1 gallon of carrier = .080 (Setting is .080:1)
If applying NH3, set to 1.000:1 if Hiniker reads lbs N/ac. Set to
4.220:1 if Hiniker reads gallons/ac (PF actual rate will be lbs N/ac).
Area Count: Set to Standard.
Revision 2
3 of 3
P.N. 2002831-21