DELTASCOPE FMP30 ISOSCOPE FMP30 DUALSCOPE FMP40

DELTASCOPE FMP30 ISOSCOPE FMP30 DUALSCOPE FMP40
DATA SHEET
Instrument series for measuring coating thickness
and surface profile height
DELTASCOPE® FMP30
DELTASCOPE® FMP10
ISOSCOPE® FMP30
ISOSCOPE® FMP10
DUALSCOPE® FMP40
Coating Thickness
Material Analysis
Microhardness
DUALSCOPE® FMP20
Material Testing
FMP10, FMP20, FMP30, FMP40 instrument series
Description
These hand-held instruments measure coating thickness easily, quickly, non-destructively and with the precision that is typical for all FISCHER instruments. Over 70
probes can be connected to FMP10 to FMP40. Thus, you can solve even the most
sophisticated measurement tasks.
Measurement range, trueness and repeatability precision depend on the connected
probe. This information can be found in the corresponding probe data sheets.
Models
DELTASCOPE ISOSCOPE DUALSCOPE DELTASCOPE ISOSCOPE DUALSCOPE
FMP10
FMP10
FMP20
FMP30
FMP30
FMP40
Basic feature scope see page 3
Basic models with Basic feature scope
Extended feature scope see page 4
Applications
(Examples)
Base material steel or iron (Fe)
• Zinc, chromium, copper coatings on steel
or iron (NF/Fe)
Extended models with extended feature
scope as several measurement memories, allocation of measurement readings
in blocks, specification limit monitoring,
various measuring modes (automatic
measurement, measurements according
to IMO PSPC, SSPC-PA2, …)
DELTASCOPE ISOSCOPE DUALSCOPE DELTASCOPE ISOSCOPE DUALSCOPE
FMP10
FMP10
FMP20
FMP30
FMP30
FMP40




• Paint, varnish or plastic coatings on steel
or iron (Iso/Fe)
Base material nonferrous metal (NF)
• Paint, varnish or plastic coatings on
aluminium, copper or brass (Iso/NF)




• Anodized coatings on aluminium (Iso/NF)

Duplex coatings varnish/Zn/Fe (Zn > 70 µm (0.03 "))
Surface profile hight according to ASTM 4471
Memory

Measurement readings
Final result, total evaluation across all stored
readings



1
up to 100
max. 1000 readings
max. 20.000 readings
DELTASCOPE ISOSCOPE DUALSCOPE DELTASCOPE ISOSCOPE DUALSCOPE
FMP10
FMP10
FMP20
FMP30
FMP30
FMP40



Block result, statistical characteristics of a
measurement block



Histogram, graphical presentation



Data transfer
Bidirectional data exchange with PC
2

DELTASCOPE ISOSCOPE DUALSCOPE DELTASCOPE ISOSCOPE DUALSCOPE
FMP10
FMP10
FMP20
FMP30
FMP30
FMP40
Storable applications
Evaluation





DELTASCOPE ISOSCOPE DUALSCOPE DELTASCOPE ISOSCOPE DUALSCOPE
FMP10
FMP10
FMP20
FMP30
FMP30
FMP40
Single readings, final result






during and after measurement






Remote control






Group separator, block result



Printer directly connectable at the instrument



Basic feature scope
DELTASCOPE ISOSCOPE DUALSCOPE DELTASCOPE ISOSCOPE DUALSCOPE
FMP10
FMP10
FMP20
FMP30
FMP30
FMP40
Measurement features
Continuous display value
Measurement with "free-running" display for continuous value display during scanning the surface, e.g. in the manufacture of tanks and containers
Single reading measurement
Reading capture each time when placing probe on surface
Measurement capture
• Automatic measurement capture when placing probe on surface
• Manual measurement capture by pressing an instrument key
• Up to 2500 ms delayed measurement capture
• Fast measurement trigger ca. 0.2 s by using "free-running" display
Audible signal for measurement capture
Audible signal reports each measurement capture
Adjust the measuring system to application
Normalization
Adaptation to the substrate material and the shape of the specimen
Corrective calibration
Adaptation to the substrate material and the shape of the specimen and to 1 or 2
thickness values by use of calibration foils.
Corrective calibration on coating
Adaption to the coating and substrate material in one step by use of one calibration
foil. Nevertheless, this kind of calibration supplies only a lower accuracy as specified in the probe data sheets.
User master calibration
Adaptation to the base material and the shape of the specimen and to 4 to 8 thickness values by use of calibration foils.
Checking current calibration state and measuring system accuracy for one application
Control whether the mean value of check measurement matches the reference value
from corrective calibration within the scope of measurement uncertainty (according
ISO/IEC Guide 98-3).
Unit of measurement
Selectable µm or mils
Measured variable
Selectable coating thickness value, count rate, simultaneous display of coating thickness and probe count rate in air or simultaneous display of probe count rate on coating and in air
Restricted operating mode
The Functions "Normalization", "Calibration", "Menu" and "Delete" can be locked
General features
Language
Selectable de, us/gb, fr, it, es, pl, cz, tr, se, br, cn, jp, kp, ru
Factory calibration
Each individual instrument is factory calibrated at several reference points with the
greatest care to ensure the highest possible degree of trueness.
Display
• Dimensions: 44 mm x 57 mm (L x W; 1.7 " x 2.2 "), graphical backlit TTF display
• Selectable contrast, brightness and automatic device turn OFF after n seconds
Connectors
• Probe socket
• USB, 2.0 compatible, mini-AB, for connecting to a PC
Power supply, power data
• 4 batteries, LR6, AA, 1.5 V
• Power consumption with unlit display: 0.3 W
• Power consumption with lit-up display: 0.5 W
• Automatic device turn OFF after ca. 5 min or non-stop operation
Instrument unit
• Dimensions: 170 mm x 90 mm x 35 mm (L x W x H; 6.6 " x 3.5 " x 1.4 ")
• Weight: 340 g (12 oz) (without probe and batteries)
• Sliding cover to protect keys and for key lock
Ambient and storage environments
• Ambient temperature range during operation: 0 … +40 °C (+32 … +104 °F)
• Storage temperature range: 5 … +60 °C (+41 … +140 °F)
• Relative humidity range: 30 … 90 %RH, non-condensing
FMP10, FMP20, FMP30, FMP40 instrument series
3
FMP10, FMP20, FMP30, FMP40 instrument series
Extended feature scope
DELTASCOPE ISOSCOPE DUALSCOPE
FMP30
FMP30
FMP40
Measurement features
Storing readings block wise
Adjustable between 2 and 20 single readings per block
Specification limit monitoring
Limit values adjustable
Outlier control
Select test method (Grubbs Test, preset standard deviation determined from test measurement)
Offset value
The freely adjustable offset value is automatically deducted from the measured value.
Area measurement
Mean value is displayed after scanning surface by probe. This measuring mode is
advantageous to determine quickly the coating thickness within the scanned area.
Matrix mode
Matrixs are built by a combination of application and measurement block memories.
This means that several automobile components (blocks) can be measured automatically, in succession, by a predefined sequence for 3 different auto types (applications), for example. Before measuring each auto component (fender, hood, etc.) —
the manually opening of the corresponding application (automobile type) and block
(auto component) is no longer required.
Measurement defined by directives
The instrument features stored measurement specifications for the following directives: SSPC-PA2, IMO PSPC, QUALANOD, QUALICOAT and user specific part definition with number of measurements per measuring spot and number of measuring
spots per specimen.
Display only mean value of i single readings
In case of rough surfaces or various material texture — its advantageous to create a
mean value from several measurements and store it as measurement value.
Automated measurement
Automatic measurement capture every n seconds;
Adjustable number of measurements for a time interval
Instrument features
4
Analog Display, engage
When making measurements in the "free-running" display mode — the analog display facilitates a quick recognition coating thickness changes.
Application linking
This function minimizes calibration as only one normalization or one corrective calibration is needed for several different (similar) applications. Linked applications use
the same measurement probe and use the same normalization and/or corrective calibration together.
Date and time
Setting of date, date format and time for measurement recording and evaluation.
Printing
Printer can be connected to the USB interface. Printing of single readings, block
result, final result and histogram
Electrical power supply via AC adapter
The FMP30 and FMP40 are battery and AC adapter powered
Ordering information
Order number
Scope of delivery
DELTASCOPE ISOSCOPE DUALSCOPE DELTASCOPE ISOSCOPE DUALSCOPE
FMP10
FMP10
FMP20
FMP30
FMP30
FMP40
605-021
605-027
605-023
605-022
605-028
605-024
DELTASCOPE ISOSCOPE DUALSCOPE DELTASCOPE ISOSCOPE DUALSCOPE
FMP10
FMP10
FMP20
FMP30
FMP30
FMP40
Carrying case
Measurement instrument, carrying strap; 4 batteries; printed guidelines; USB interface cable; support CD with USB drivers, operator‘s manual, software program
FISCHER DataCenter to evaluate, record and archive measurement data in a comfortable way, software program PC-Datex to transfer measurement data into Excel
sheets
Optional Accessories/ Spare parts
DELTASCOPE ISOSCOPE DUALSCOPE DELTASCOPE ISOSCOPE DUALSCOPE
FMP10
FMP10
FMP20
FMP30
FMP30
FMP40
Carrying case for measurement instrument
and accessory
604-148
Adapter E-probe/F-socket, connecting Eprobes to measurement instrument
604-214
NiMH battery charger, Mignon, AA, LR6,
1.5 V, 2100 mA
604-335
Support stand V12 BASE, with manual
probe lowering device. Measurements with
support stand provides a higher measurement accuracy. The supplied stop device
simplifies the specimen positioning.
604-420
Support stand V12 MOT, with motorized
probe lowering device for top repeatability.
Controlled directly by stand keys. The supplied stop device simplifies the specimen
positioning.
604-374
Protective cover for measurement instrument
604-149
Calibration foils, Calibration foil sets
For calibration measurement system a broad assortment of calibration foils is available from FISCHER. On your request FISCHER issues a Factory Certificate for your
calibration foil.
Module COM FMP30/40, additional
RS232 interface with Sub-Min-D socket for
data transfer (must be mounted in factory)
604-500
Interface connection set for module COM
FMP30/40
602-341
Module Bluetooth® FMP30/40, additional
interface for wireless data transfer (must be
mounted in factory)
604-480
AC adapter
604-290
NiMH battery Set FMP, loading in instrument
via AC adapter possible
604-295
Probes
A probe must have specific properties for each field of application to attain best
measurement results. Please feel free to contact our professionals at FISCHER to assist
in finding the right probe for your individual need.
FMP10, FMP20, FMP30, FMP40 instrument series
5
10012017
DUALSCOPE®, DELTASCOPE® and ISOSCOPE® are registered trademarks of Helmut Fischer GmbH Institut für Elektronik und Messtechnik in
Germany and in other countries.
Bluetooth® is a registered trade mark of the Bluetooth SIG, USA.
902-123
FMP10, FMP20, FMP30, FMP40 instrument series
www.helmut-fischer.com
Coating Thickness
Material Analysis
Microhardness
Material Testing