Hitachi Compute Blade 500 Series System Overview

Hitachi Compute Blade 500 Series System Overview
Hitachi Compute Blade 500 Series
System Overview Guide
Document Organization
Product Version
Getting Help
Contents
MK-91CB500001-12
© 2012-2015 Hitachi, Ltd. All rights reserved.
No part of this publication may be reproduced or transmitted in any form or by any means,
electronic or mechanical, including photocopying and recording, or stored in a database or retrieval
system for any purpose without the express written permission of Hitachi, Ltd.
Hitachi, Ltd., reserves the right to make changes to this document at any time without notice and
assumes no responsibility for its use. This document contains the most current information available
at the time of publication. When new or revised information becomes available, this entire
document will be updated and distributed to all registered users.
Some of the features described in this document might not be currently available. Refer to the most
recent product announcement for information about feature and product availability, or contact
Hitachi Data Systems Corporation at https://portal.hds.com.
Notice: Hitachi, Ltd., products and services can be ordered only under the terms and conditions of
the applicable Hitachi Data Systems Corporation agreements. The use of Hitachi, Ltd., products is
governed by the terms of your agreements with Hitachi Data Systems Corporation.
Hitachi is a registered trademark of Hitachi, Ltd., in the United States and other countries. Hitachi
Data Systems is a registered trademark and service mark of Hitachi, Ltd., in the United States and
other countries.
Archivas, Essential NAS Platform, HiCommand, Hi-Track, ShadowImage, Tagmaserve, Tagmasoft,
Tagmasolve, Tagmastore, TrueCopy, Universal Star Network, and Universal Storage Platform are
registered trademarks of Hitachi Data Systems Corporation.
AIX, AS/400, DB2, Domino, DS6000, DS8000, Enterprise Storage Server, ESCON, FICON,
FlashCopy, IBM, Lotus, MVS, OS/390, RS6000, S/390, System z9, System z10, Tivoli, VM/ESA,
z/OS, z9, z10, zSeries, z/VM, and z/VSE are registered trademarks or trademarks of International
Business Machines Corporation.
All other trademarks, service marks, and company names in this document or website are
properties of their respective owners.
Microsoft product screen shots are reprinted with permission from Microsoft Corporation.
ii
Hitachi Compute Blade 500 Series System Overview Guide
Contents
Preface ................................................................................................ v
Intended Audience ................................................................................................. vi
Product Version ..................................................................................................... vi
Release Notes ........................................................................................................ vi
Document Organization .......................................................................................... vi
Referenced Documents .......................................................................................... vi
Document conventions .......................................................................................... vii
Convention for storage capacity values ................................................................... vii
Getting help ......................................................................................................... viii
Comments ........................................................................................................... viii
1 System Overview ............................................................................... 1-1
Server Chassis (enclosure) ................................................................................... 1-2
Overview ...................................................................................................... 1-2
Server Chassis Specifications .......................................................................... 1-3
Modules ........................................................................................................ 1-4
Management Monitor for Maintenance ............................................................ 1-6
Power Distribution ......................................................................................... 1-7
Power Cable ................................................................................................. 1-8
Identification ................................................................................................ 1-9
Switches, Indicators and Connectors ............................................................. 1-10
Server Blade ...................................................................................................... 1-11
Overview .................................................................................................... 1-11
Switches, Indicators and Connectors (Half-wide blade CB 520A A1/CB 520H
A1/CB 520H B1/B2) ..................................................................................... 1-13
Switches, Indicators and Connectors (Half-wide blade CB 520H B3) ................ 1-15
Switches, Indicators and Connectors (Full-wide blade) ................................... 1-17
Switches, Indicators and Connectors (Full-wide blade CB 520X B1/B2) ............ 1-19
HDD slot, order of installation, and indicator ........................................................ 1-21
HDD slot and order of installation ................................................................. 1-21
Indicators ................................................................................................... 1-23
PCI slots ..................................................................................................... 1-24
Management Module .......................................................................................... 1-24
Overview .................................................................................................... 1-24
Switches, Indicators and Connectors ............................................................. 1-24
Switch Module ................................................................................................... 1-25
iii
Hitachi Compute Blade 500 Series System Overview Guide
Overview ....................................................................................................
User ports ...................................................................................................
Switches, Indicators and Connectors .............................................................
Power Supply Module ........................................................................................
Indicator and connector ...............................................................................
Fan Module ......................................................................................................
Indicator .....................................................................................................
User Maintenance ..............................................................................................
1-25
1-28
1-29
1-36
1-36
1-37
1-37
1-37
2 Specification ..................................................................................... 2-1
System Unit Specifications .................................................................................... 2-2
Server Chassis Specifications .......................................................................... 2-2
Server Blade Specifications ............................................................................ 2-3
Management Module Specifications ............................................................... 2-15
Switch Module Specifications ........................................................................ 2-15
Power Supply Module Specifications .............................................................. 2-20
Fan Module Specifications ............................................................................ 2-21
Transceiver and Cable Specifications ............................................................. 2-22
Interface Port Pin-outs ....................................................................................... 2-23
USB Connector ............................................................................................ 2-23
RS-232C Interface Connector (Management Module) .................................... 2-23
LAN Connector ........................................................................................... 2-24
A Service Life Limited Parts ................................................................... A-1
About service life limited parts for CB 500 ............................................................ A-2
B Expiration of RoHS exemption ............................................................ B-1
About expiration of RoHS exemption ..................................................................... B-2
iv
Hitachi Compute Blade 500 Series System Overview Guide
Preface
This document describes how to use the Compute Blade 500 series.
This preface includes the following information:
Notice: The use of Compute Blade 500 series and all other Hitachi Data
Systems products is governed by the terms of your agreement(s) with Hitachi
Data Systems.
□ Intended Audience
□ Product Version
□ Release Notes
□ Document Organization
□ Referenced Documents
□ Document conventions
□ Convention for storage capacity values
□ Getting help
□ Comments
Preface
Hitachi Compute Blade 500 Series System Overview Guide
v
Intended Audience
This document is intended for the personnel who are involved in planning,
managing, and performing the tasks to prepare your site for Compute Blade
installation and to install the same.
This document assumes the following:
•
The reader has a background in hardware installation of computer
systems.
•
The reader is familiar with the location where the Compute Blade will be
installed, including knowledge of physical characteristics, power systems
and specifications, and environmental specifications.
Product Version
This document revision applies to CB 520X B2.
Release Notes
Read the release notes before installing and using this product. They may
contain requirements or restrictions that are not fully described in this
document or updates or corrections to this document.
Document Organization
The table below provides an overview of the contents and organization of this
document. Click the chapter title in the left column to go to that chapter. The
first page of each chapter provides links to the sections in that chapter.
Chapter
Description
Chapter 1, System Overview
Describes the parts of the server chassis, and
various modules.
Chapter 2, Specification
Describes the specifications of the system
interface.
Appendix A, Service Life Limited Parts Describes service life limited parts.
Appendix B, Expiration of RoHS
exemption
Describes expiration of RoHS exemption.
Referenced Documents
vi
•
Hitachi Compute Blade 500 Series Management Module Setup Guide,
MK-91CB500014
•
Hitachi Compute Blade 500 Series Site Planning Guide, EBS-DOC-023
Preface
Hitachi Compute Blade 500 Series System Overview Guide
•
Hitachi Compute Blade 500 Series System Service Manual,
FE-91CB500004
Document conventions
The term “Compute Blade” refers to all the models of the Compute Blade,
unless otherwise noted.
This document uses the following typographic conventions:
Convention
Regular text bold
Description
In text: keyboard key, parameter name, property name,
hardware labels, hardware button, hardware switch.
In a procedure: user interface item
Italic
Variable, emphasis, reference to document title, called-out term
screen/code
Command name and option, drive name, file name, folder name,
directory name, code, file content, system and application
output, user input
< > (angled brackets) Variable (used when italic is not enough to identify variable).
[ ] (square bracket)
Optional values
{ } braces
Required or expected value
| vertical bar
Choice between two or more options or arguments
This document uses the following icons to draw attention to information:
Icon
Meaning
Description
WARNING This indicates the presence of a potential risk that might
cause death or severe injury.
CAUTION
This indicates the presence of a potential risk that might
cause relatively mild or moderate injury.
NOTICE
This indicates the presence of a potential risk that might
cause severe damage to the equipment and/or damage to
surrounding properties.
Note
This indicates notes not directly related to injury or severe
damage to equipment.
Tip
This indicates advice on how to make the best use of the
equipment.
Convention for storage capacity values
Physical storage capacity values (for example, disk drive capacity) are
calculated based on the following values:
Preface
Hitachi Compute Blade 500 Series System Overview Guide
vii
Physical capacity unit
Value
1 kilobyte (KB)
1,000 (103) bytes
1 megabyte (MB)
1,000 KB or 1,0002 bytes
1 gigabyte (GB)
1,000 MB or 1,0003 bytes
1 terabyte (TB)
1,000 GB or 1,0004 bytes
1 petabyte (PB)
1,000 TB or 1,0005 bytes
1 exabyte (EB)
1,000 PB or 1,0006 bytes
Logical storage capacity values (for example, logical device capacity) are
calculated based on the following values:
Logical capacity unit
Value
1 block
512 bytes
1 KB
1,024 (210) bytes
1 MB
1,024 KB or 1,0242 bytes
1 GB
1,024 MB or 1,0243 bytes
1 TB
1,024 GB or 1,0244 bytes
1 PB
1,024 TB or 1,0245 bytes
1 EB
1,024 PB or 1,0246 bytes
Getting help
The Hitachi Data Systems customer support staff is available 24 hours a day,
seven days a week. If you need technical support, log on to the Hitachi Data
Systems Portal for contact information: https://portal.hds.com.
Comments
Please send us your comments on this document: doc.comments@hds.com.
Include the document title and number including the revision level (for
example, -07), and refer to specific sections and paragraphs whenever
possible. All comments become the property of Hitachi Data Systems
Corporation.
Thank you!
viii
Preface
Hitachi Compute Blade 500 Series System Overview Guide
1
System Overview
This chapter describes the parts of the server chassis, and various modules.
□ Server Chassis (enclosure)
□ Server Blade
□ HDD slot, order of installation, and indicator
□ Management Module
□ Switch Module
□ Power Supply Module
□ Fan Module
□ User Maintenance
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
1-1
Server Chassis (enclosure)
This section describes server chassis.
Overview
The 6U server chassis can contain up to eight server blades and four switch
modules. Compared with a 1U server chassis with an external rack mount
network switch and FC switch, the 6U server chassis consumes less space,
requires fewer cables and weighs less. The connection between each module
is through the internal backplane in the server chassis. Thus a complicated
cable connection is unnecessary. When you need to add a server blade to a
chassis, you can add the server blade just by inserting it in a spare slot. The
system is designed to consolidate existing rack-mount server systems, for
server consolidation and for operation in a data center. Switch modules can
be selected according to your needs. Management modules, switch modules,
power supply modules and fan modules can each be provided in a redundant
configuration such that the system can continue to operate even if one of the
modules fails. Power supplies required for server blades are installed in a
server chassis. Thus stable electric power can be supplied in a very small
space. The external interface is shared between server blades using a
switching function to conserve space. The server chassis for CB 500 offers the
following key features:
1-2
•
Up to 8 multi-core 2-socket processor half-wide blades
•
Up to 4 multi-core 4-socket processor full-wide blades
•
Up to 4 high-throughput flexible IO switch modules
•
High density laminated substrate backplane for future IO interfaces
•
80 PLUS Platinum power supply and Power Capping with Energy reduction
technologies
•
High levels of reliability/availability/maintainability (RAS) including
multiple redundant configurations and customer serviceability
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
Figure 1-1 Server chassis
Server Chassis Specifications
This subsection provides specifications for server chassis.
Table 1-1 Server Chassis Specifications
Items
Form factor
Number of slot
Chassis size
Specifications
Type
19 inch Rack Mount (EIA)
Height
6U (EIA)
Server blade
8
Switch module
4
Management module
2 (Redundant)
Power supply module
4 (Redundant)
Fan module
6 (Redundant)
Height
262 mm (Excluding protrusions)
Width
447 mm (Excluding protrusions)
Depth
791 mm (Excluding protrusions)
Front panel
1
Mass
Maximum: 130 kg
(with all modules installed; including
rack rails)
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
1-3
Items
Specifications
Temperature
5 to 40°C [Non-operating: -10 to
43°C]1
Humidity
20 to 80 % [Non-operating: 10 to 90
%]
Vibration
2.45 m/s2 max. [Non-operating: 9.80
m/s2 max.]
Cooling
Method
Air-cooling by fan.
Air intake: front side.
Air exhaust: rear side.
Flow
14.4 m3 / min
Notes:
1.
5 to 30°C [Non-operating: -10 to 43°C] for CB 520H B2 with CPU E5-2637v2
installed. 5 to 35°C [Non-operating: -10 to 43°C] for CB 520H B3 with CPU
E5-2699v3, E5-2697v3, E5-2667v3, and E5-2637v3 installed.
Table 1-2 Maximum and Minimum Configuration
Configuration
Items
Base unit
Minimum
Maximum
Front panel
1
1
Fan module
6
6
Server blade
1
8
Switch module
0
4
Management module
1
2
Power supply module
1
4
Modules
This subsection provides locations of modules in the server chassis.
1-4
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
Figure 1-2 Front view
Figure 1-3 Rear view
Table 1-3 Server Chassis Modules
Location
Component
Location
Component
1
Server blade #0
13
Management module #0
2
Server blade #1
14
Management module #1
3
Server blade #2
15
Power supply module #0
4
Server blade #3
16
Power supply module #1
5
Server blade #4
17
Power supply module #2
6
Server blade #5
18
Power supply module #3
7
Server blade #6
19
Fan module #0
8
Server blade #7
20
Fan module #1
9
Switch module #0
21
Fan module #2
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
1-5
Location
Component
Location
Component
10
Switch module #1
22
Fan module #3
11
Switch module #2
23
Fan module #4
12
Switch module #3
24
Fan module #5
Management Monitor for Maintenance
The Hitachi Compute Blade system provides two types of management
monitor.
•
Web console
•
LCD touch console
Web Console
The Web console is a general application to control or manage the Hitachi
Compute Blade system. By connecting between the management module
installed in the system and the user system console on the network, you can
display the system status and failed parts, and set up the configuration.
The Web console is connected to the management LAN port #0 on
management module. The management LAN port #0 is a standard RJ45
connector and accepts both a cross-over cable and straight-through cable.
Figure 1-4 Connecting the system console
LCD Touch Console
A LCD touch console unit is the optional product. Connecting it to USB port of
the front panel in server chassis, it is easy to display the system status and
failed parts, and set up the configuration without a system console and Web
console application.
1-6
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
Hitachi recommends that the LCD touch console be available for secondary
maintenance application.
The LCD touch console is directly connected to the USB port #0 or 1 on front
panel module. The USB ports are standard USB connectors.
Figure 1-5 Connecting the LCD touch console
Hot-swappable Modules
All modules are designed to be hot-swappable. The following figure shows the
side of the server chassis from which hot-swap is performed for each module.
Figure 1-6 Hot-swappable Modules
Power Distribution
One power cable is required per power supply module. (Four power cables
maximum) In the basic configuration, power cables from a server chassis
connect to a distribution box, and the distribution box is connected to the
power outlet. Hitachi recommends that power outlets use NEMA L6-30R (30
A/250 V) or IEC60309-32 (32A/240V) receptacles.
For more information, see;
– Hitachi Compute Blade 500 Series Site Planning Guide
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
1-7
Figure 1-7 Power Distribution
Table 1-4 Specifications of the Power Outlet Plug and Receptacle
Items Regulation
1
2
North
America
Power
Type and
Description
Rating
capacity
200-240 200-240
V
VAC
distribution
box
International 240 V
200-240
VAC
distribution
box
Electrical plug and
receptacle
Plug
Receptacle
30 A –
250 V
Grounded
2poles/3wires
(NEMA
L6-30P)
(NEMA
L6-30R)
(IEC309 Plug)
(IEC309
Socket)
32 A –
250 V
Grounded
2poles/3wires
Power Cable
A power cable connects a power supply module to a distribution box.
1-8
•
Power supply module side: IEC60320-C19
•
Distribution box side: IEC60320-C20
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
Figure 1-8 Power Cable
Identification
Server chassis and server blades each come with ID tags to facilitate
identification during installation and maintenance.
The ID tag enables identification of the model name, serial number, and
revision of the target before maintenance is performed, allowing errors in
maintenance to be avoided.
Figure 1-9 ID Tag
Figure 1-10 Location ID
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
1-9
Figure 1-11 Label Tag
Switches, Indicators and Connectors
Figure 1-12 Front panel
Table 1-5 Front panel Switches, Indicators and Connectors
Location
Name
State
Description
1
USB port 0 (USB0)
-
Server chassis USB ports.
2
USB port 1 (USB1)
-
3
Forced power off
switch (POFF)
-
Press and hold for at least four seconds to
force the main power off.
4
Power LED (PWR)
Green-On
Main power of one or more server blades
is on.
Green-Blink The server chassis is shut down by the
management module.
Amber-On
Main power of all the server blades is off.
Amber-Blink Initialization when the power is first
supplied to the server chassis.
1-10
5
Alarm LED (ALM)
Red -On
Alarm, the server chassis found a non
redundant failure.
6
Warning LED (WRN)
Amber-On
Warning, a failure was detected in one or
more modules.
7
Identify LED (LID)
Blue-On
The server chassis is identified.
8
Buzzer stop switch
(BZSTP)
-
Stops the buzzer
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
Server Blade
This section describes server blades.
Overview
The CB 500 server blade offers the following key features:
•
High-performance Intel multi-core processor with QPI technology for
high-throughput and low-latency.
•
High reliability functions through the processor, memory and HDD
reliability/availability/maintainability features, such as memory scrubbing
(self-error-correcting), memory mirroring function (memory duplication),
and integrated Hardware RAID 1.
•
High density, high performance optimized for enterprise data center,
virtualization, high-speed computation, and flexible IO capability.
A server blade contains processors, memory, HDDs, and other components,
and is available in either of two form factors: the "half-wide" blade; "fullwide" blade. There are also two types of half-wide blades, the "storage
expansion" blade for additional HDDs and the "PCI expansion" blade for
additional PCI Express cards.
For detailed specifications, see System Unit Specifications on page 2-2.
Table 1-6 Function and Model Names
Number of
processors
Form factor
Half-wide blade CB 520A A1, CB 520H
A1/B1/B2
2
CB 520H B3
Size (W x D x H: mm)
215.4 x 492.7 x 51.1
215.4 x 500.6 x 51.1
Storage expansion blade
0
435.3 x 492.7 x 55.5
PCI expansion blade
0
435.3 x 492.7 x 55.5
Full-wide blade CB 540A A1/B1
4
435.3 x 492.7 x 55.5
CB 520X B1/B2
2
Figure 1-13 Half-wide Blade
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
1-11
Figure 1-14 Storage Expansion Blade
Figure 1-15 PCI Expansion Blade
Figure 1-16 Full-wide Blade
With CB 520X B1/B2, you can connect two server blades using the 2-blade
SMP connection board to create SMP configuration with four CPUs and you
can connect four server blades using the 4-blade SMP connection board to
create SMP configuration with eight CPUs shown in the following figure. SMP
function stands for Symmetric Multi Processing (SMP) between server blades.
1-12
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
Figure 1-17 Full-wide Blade (CB 520X B1/B2)
Switches, Indicators and Connectors (Half-wide blade CB 520A
A1/CB 520H A1/CB 520H B1/B2)
Figure 1-18 Server Blade (Half-wide blade CB 520A A1/CB 520H A1/CB
520H B1/B2)
Table 1-7 Server Blade Switches, Indicators and Connectors (Half-wide
blade CB 520A A1/CB 520H A1/CB 520H B1/B2)
Location
1
Name
USB port
State
-
Description
USB port in the server
blade.
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
1-13
Location
Name
State
Description
2
NMI reset switch
-
Press this switch to issue a
Non-Maskable Interrupt
(NMI) of the server blade.
3
KVM port
-
Provides VGA, serial port
and 2 USB port outputs.
Connect a KVM cable to
this port.1
4
Power switch with Power LED
-
Press this switch to poweron.
Press and hold this switch
for four seconds or more
to force the main poweroff.2
Green-On
Main power of the server
blade is turned on.
Green-Blink
Main power of the server
blade is turned off.
Slow blink: The server
blade is ready to be turned
on.
Rapid blink: The server
blade is initializing.
5
Location Identify LED (LID)
Blue-On
Identifies the server blade.
6
Attention LED (ATN)
Amber-On
Configuration mismatch
errors other than failures
are detected in the server
blade, such as the installed
Mezzanine card does not
correspond to or does not
support the switch module.
Indicates explicitly that the
power button with LED was
pressed. The LED is turned
on when you press the
power button, and then
turned off when the main
power is turned on.3
1-14
7
Alarm LED (ALM)
Amber-On
Indicates a fault that
requires an HDD to be
exchanged was detected in
the server blade.
8
Diagnostic Panel LP
Green-On
The LED panel on the
diagnostic panel is active.
S BRD
Amber-On
The motherboard needs to
be replaced.
MIS
Amber-On
Unsupported combination
of the DIMM, CPU, and
HDD.
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
Location
Name
State
Description
NMI
Amber-On
A Non-Maskable Interrupt
(NMI) was generated.
TEMP
Amber-On
The maximum
temperature limit was
exceeded.
MEM
Amber-On
A memory failure was
detected.
ADJ
-
Not supported.
Notes:
1.
When using the USB port of KVM cable except keyboard and mouse, you should use
the device with a rated maximum current limit 500 mA per two ports, or the USB
device that can be external powered.
2.
When POWER LED starts blinking from lighting solid, release the button. If you press
the power switch for six seconds or more, the power may turn on after forced turnoff. If so, check that HDD access LED is not illuminated, and then press and hold the
power button for four seconds or more.
3.
Error cannot be displayed while from pressing the power button until turning on the
main power.
Switches, Indicators and Connectors (Half-wide blade CB 520H B3)
Figure 1-19 Server Blade (Half-wide blade CB 520H B3)
Table 1-8 Server Blade Switches, Indicators and Connectors (Half-wide
blade CB 520H B3)
Location
Name
State
Description
1
USB port
-
USB port in the server
blade.
2
NMI reset switch
-
Press this switch to issue a
Non-Maskable Interrupt
(NMI) of the server blade.
3
KVM port
-
Provides VGA, serial port
and 2 USB port outputs.
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
1-15
Location
Name
State
Description
Connect a KVM cable to
this port.1
4
Power switch with Power LED
-
Press this switch to poweron.
Press and hold this switch
for four seconds or more to
force the main power-off.2
Green-On
Main power of the server
blade is turned on.
Green-Blink
Main power of the server
blade is turned off.
Slow blink: The server
blade is ready to be turned
on.
Rapid blink: The server
blade is initializing.
5
Location Identify LED (LID)
Blue-On
Identifies the server blade.
6
Attention LED (ATN)
Amber-On
Configuration mismatch
errors other than failures
are detected in the server
blade, such as the installed
Mezzanine card does not
correspond to or does not
support the switch module.
Indicates explicitly that the
power button with LED was
pressed. The LED is turned
on when you press the
power button, and then
turned off when the main
power is turned on.3
1-16
7
Alarm LED (ALM)
Amber-On
Indicates a fault that
requires an HDD to be
exchanged was detected in
the server blade.
8
Expansion LED
Amber-On
Indicates a fault that
requires an expansion
blade to be exchanged was
detected.
9
Diagnostic LED
LP
Green-On
The LED panel is active.
SYS BRD
Amber-On
The motherboard needs to
be replaced.
NMI
Amber-On
A Non-Maskable Interrupt
(NMI) was generated.
SEE EXP
Amber-On
Not supported
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
Location
Name
State
Description
MIS
Amber-On
Unsupported combination
of the DIMM, CPU, and
HDD.
TEMP
Amber-On
The maximum temperature
limit was exceeded.
MEM
Amber-On
A memory failure was
detected.
STOP BP
Amber-On
SAS Backplane failure was
detected.
CPU1
Amber-On
CPU1 failure was detected.
CPU2
Amber-On
CPU2 failure was detected.
Notes:
1.
When using the USB port of KVM cable except keyboard and mouse, you should use
the device with a rated maximum current limit 500 mA per two ports, or the USB
device that can be external powered.
2.
When POWER LED starts blinking from lighting solid, release the button. If you press
the power switch for six seconds or more, the power may turn on after forced turnoff. If so, check that HDD access LED is not illuminated, and then press and hold the
power button for four seconds or more.
3.
Error cannot be displayed while from pressing the power button until turning on the
main power.
Switches, Indicators and Connectors (Full-wide blade)
Figure 1-20 Server Blade
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
1-17
Table 1-9 Server Blade Switches, Indicators and Connectors
Location
Name
State
Description
1
USB port
-
USB port in the server
blade.
2
NMI reset switch
-
Press this switch to issue a
Non-Maskable Interrupt
(NMI) of the server blade.
3
KVM port
-
Provides VGA, serial port
and 2 USB port outputs.
Connect a KVM cable to
this port.1
4
Power switch with Power LED
-
Press this switch to poweron.
Press and hold this switch
for four seconds or more
to force the main poweroff.2
Green-On
Main power of the server
blade is turned on.
Green-Blink
Main power of the server
blade is turned off.
Slow blink: The server
blade is ready to be turned
on.
Rapid blink: The server
blade is initializing.
5
Location Identify LED (LID)
Blue-On
Identifies the server blade.
6
Attention LED (ATN)
Amber-On
Configuration mismatch
errors other than failures
are detected in the server
blade, such as the installed
Mezzanine card does not
correspond to or does not
support the switch module.
Indicates explicitly that the
power button with LED
was pressed. The LED is
turned on when you press
the power button, and
then turned off when the
main power is turned on.3
7
Alarm LED (ALM)
Amber-On
Indicates a fault that
requires an HDD to be
exchanged was detected in
the server blade.
8
Diagnostic Panel LP
Green-On
The LED panel is active.
Amber-On
The motherboard needs to
be replaced.
S BRD
1-18
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
Location
Name
State
Description
MIS
Amber-On
Unsupported combination
of the DIMM, CPU, and
HDD.
NMI
Amber-On
A Non-Maskable Interrupt
(NMI) was generated.
TEMP
Amber-On
The maximum
temperature limit was
exceeded.
MEM
Amber-On
A memory failure was
detected.
ADJ
-
Not supported.
Notes:
1.
When using the USB port of KVM cable except keyboard and mouse, you should use
the device with a rated maximum current limit 500 mA per two ports, or the USB
device that can be external powered.
2.
When POWER LED starts blinking from lighting solid, release the button. If you press
the power switch for six seconds or more, the power may turn on after forced turnoff. If so, check that HDD access LED is not illuminated, and then press and hold the
power button for four seconds or more.
3.
Error cannot be displayed while from pressing the power button until turning on the
main power.
Switches, Indicators and Connectors (Full-wide blade CB 520X
B1/B2)
Figure 1-21 Server Blade (CB 520X B1/B2)
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
1-19
Table 1-10 Server Blade Switches, Indicators and Connectors
Location
Name
State
Description
1
USB
-
USB port in the server
blade.
2
NMI Reset Switch
-
Press this switch to issue a
Non-Maskable Interrupt
(NMI) of the server blade.
3
KVM
-
Provides VGA, serial port
and 2 USB port outputs.
Connect a KVM cable to
this port.1
4
Enclosure Power LED with
Integrated Power Switch
-
Press this switch to poweron.
Press and hold this switch
for four seconds or more to
force the main power-off.2
Green-On
Main power of the server
blade is turned on.
Green-Blink
Main power of the server
blade is turned off.
Slow blink: The server
blade is ready to be turned
on.
Rapid blink: The server
blade is initializing.
5
Enclosure Identify LED
Blue-On
Identifies the server blade.
6
Error Log LED
Amber-On
Configuration mismatch
errors other than failures
are detected in the server
blade, such as the installed
Mezzanine card does not
correspond to or does not
support the switch module.
Indicates explicitly that the
power button with LED was
pressed. The LED is turned
on when you press the
power button, and then
turned off when the main
power is turned on.3
1-20
7
Enclosure Fault LED
Amber-On
Indicates a fault that
requires an HDD to be
exchanged was detected in
the server blade.
8
Primary LED
White-On
Indicates this is the
primary server blade.
9
QPI Link Fault LED (ERR)
Amber-On
An error occurred in QPI
link in SMP configuration.
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
Location
Name
State
Description
10
QPI Link Status LED (LNK)
Green-On
QPI is linked in SMP
configuration.
11
Diagnostic Panel
LP
Green-On
The LED panel is active.
S BRD
Amber-On
The motherboard needs to
be replaced.
MIS
Amber-On
Unsupported combination
of the DIMM, CPU, and
HDD.
NMI
Amber-On
A Non-Maskable Interrupt
(NMI) was generated.
TEMP
Amber-On
The maximum temperature
limit was exceeded.
MEM
Amber-On
A memory failure was
detected.
ADJ
-
Not supported.
Notes:
1.
When using the USB port of KVM cable except keyboard and mouse, you should use
the device with a rated maximum current limit 500 mA per two ports, or the USB
device that can be external powered.
2.
When POWER LED starts blinking from lighting solid, release the button. If you press
the power switch for six seconds or more, the power may turn on after forced turnoff. If so, check that HDD access LED is not illuminated, and then press and hold the
power button for four seconds or more.
3.
Error cannot be displayed while from pressing the power button until turning on the
main power.
HDD slot, order of installation, and indicator
HDD slot and order of installation
Figure 1-22 Half-wide Blade
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
1-21
Figure 1-23 Full-wide Blade
Figure 1-24 Full-wide Blade (CB 520X B1/B2)
Table 1-11 HDD slot and order of installation
Location
1
Form factor
Half-wide blade
2
3
Storage expansion blade
HDD slot 0
1
HDD slot 1
2
HDD expansion slot 0 1
4
HDD expansion slot 1 2
5
HDD expansion slot 2 3
6
HDD expansion slot 4 4
7
HDD expansion slot 5 5
8
HDD expansion slot 6 6
9
Full-wide blade LSI SAS 2008
HDD slot 0
1
HDD slot 1
2
HDD slot 0
1
12
HDD slot 2
2
13
SMP configuration HDD slot 0
1
14
HDD slot 1
1
15
HDD slot 0
2
10
11
1-22
Order of
installation
Slot
LSI SAS 2004
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
Location
Form factor
Order of
installation
Slot
16
HDD slot 1
2
17
HDD slot 0
3
18
HDD slot 1
3
19
HDD slot 0
4
20
HDD slot 1
4
Indicators
Figure 1-25 Indicators
Table 1-12 Indicators for SAS HDD/SAS SSD
Location
1
Name
Active LED
2
Fault LED
State
Description
Green-On
SAS drive is in idle status.
Green-Blink
SAS drive is in either start,
active, or rebuilding as the
source drive status.
Amber-On
An error occurs in SAS
drive1.
Amber-Blink
SAS drive is in rebuilding as
the source drive status.
Notes:
1.
The LED may be turned on due to initializing after activating. However, this situation
is not error when the LED is turned off about a minute later. If the LED is not turned
off, contact the sales representative or maintenance personnel.
Table 1-13 Indicators for SATA HDD
Location
Name
State
Description
1
Active LED Green-Blink SATA drive is accessed; the source drive is used for
rebuilding.
2
Fault LED
Amber-On
An error occurs in the drive.
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
1-23
PCI slots
Figure 1-26 PCI slots
Tip: PCI expansion slot 4 is behind PCI expansion slot 2. PCI expansion slot 5
is behind PCI expansion slot 3. Both PCI expansion slot 4 and PCI expansion
slot 5 are internal slots of the PCI expansion blade.
Management Module
This section describes the management module.
Overview
The management module provides power control of the modules, status
monitoring, system console, and management network functions. One
(standard) or two (maximum) management modules can be mounted in a
server chassis. With two management modules installed, the modules provide
a redundant configuration. One is the primary module and the other is the
secondary module.
To set up the management module configuration, see:
•
Hitachi Compute Blade 500 Series Management Module Setup Guide
Switches, Indicators and Connectors
Figure 1-27 Management Module
1-24
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
Table 1-14 Management Module Switches, Indicators and Connectors
Location
1
Name
LAN Link Speed LED
State
Yellow-On
Description
1000BASE-T
Yellow-Blink Link communication.
Green-On
100BASE-TX
Green-Blink Link communication.
2
LAN Status LED
Off
10BASE-T or no link.
Green-On
Link established.
Green-Blink Link communication.
3
Management LAN Port #0
(MGMT0)
-
LAN port 0 for the management
network
4
Management LAN Port #1
(MGMT1)
-
LAN port 1 for the management
network
5
Maintenance LAN Port
(MAINT)
-
LAN port for maintenance
6
Serial Port (SER)
-
Serial port for the management
module console.
7
Shut Down switch (SHDN)
-
Press and hold for at least four
seconds to turn off the power.
8
Heartbeat LED (HB)
Green-Blink F/W is active and working normally
9
Power LED (PWR)
Green-On
Powered-on, normal operation.
Green-Blink The system is shutting down or
booting
10
Identify LED (LID)
Blue-On
This module is identified.
11
Alarm LED (ALM)
Red-On
Alarm, an error was detected
12
Primary LED (MSR)
Green-On
This module is currently active. i.e.
not standby
13
Remote LED (RMT)
Green-On
The management module is
accessed remotely.
Switch Module
This section describes switch modules.
Overview
The backplane within the server chassis interconnects the switch module to
the server blades. Each server blade connects to the backplane and thus to
the switch modules through an onboard CNA or Mezzanine cards on the
server blade.
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
1-25
The following shows the rules for installing the modules:
The Mezzanine card on the server blade must match precisely the switch
modules to which it connects for successful activation. Any mismatch will be
detected as a configuration error.
•
A Mezzanine card installed in mezzanine slot 1 of CB 520H A1 or CB 520A
A1 connects to the switch modules installed in switch slots 0 and 1.
•
An onboard CNA in the CB 520H B1/B2/B3 connects to the switch
modules installed in switch slots 0 and 1.
•
A Mezzanine card installed in mezzanine slot 2 of CB 520H A1/B1/B3 or
CB 520A A1 connects to the switch modules installed in switch slots 2 and
3.
Figure 1-28 Relationship between Mezzanine Card and Switch Module (CB
520H A1, CB 520A A1)
Figure 1-29 Relationship between Mezzanine Card and Switch Module (CB
520H B1/B2/B3)
1-26
•
Mezzanine cards installed in mezzanine slot 1 and slot 3 of CB 540A A1
connect to switch modules installed in switch module slot 0 and slot 1.
•
Onboard CNAs 1 and 2 in the CB 540A B1 connect to the switch modules
installed in switch slots 0 and 1.
•
Mezzanine cards installed in mezzanine slot 2 and slot 4 of CB 540A A1 or
B1 connect to switch modules installed in switch module slot 2 and slot 3.
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
Figure 1-30 Relationship between Mezzanine Card and Switch Module (CB
540A A1)
Figure 1-31 Relationship between Mezzanine Card and Switch Module (CB
540A B1)
•
Mezzanine cards installed in mezzanine slot 2 and slot 4 of CB 520X
B1/B2 connect to switch modules installed in switch module slot 2 and
slot 3.
•
Onboard CNA 1 in the CB 520X B1/B2 connects to the switch modules
installed in switch slots 0 and 1.
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
1-27
Figure 1-32 Relationship between Mezzanine Card and Switch Module (CB
520X B1/B2)
Table 1-15 Switch Module form-factors
Size
(W x D x H: mm)
Form factor
Single-width
Available
32.3 x 252 x 161
Yes
Figure 1-33 Switch Module
User ports
All external ports of a switch module are available even if only one server
blade is installed.
To set up the switch module configuration, see Switch Module Specifications
on page 2-15.
The following is the number of useful user ports.
Table 1-16 Number of usable User Ports
Switch module type
1 Gb/sec LAN switch module
1-28
Number of installed switch modules
One
Two
Three
Four
20 ports
4
8
12
16
40 ports
8
16
24
32
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
Number of installed switch modules
Switch module type
1/10 Gb/sec LAN switch
module
One
1 Gb/sec ports
Two
Three
Four
4
8
12
16
10 Gb/sec ports 2
4
6
8
1 Gb/sec LAN pass-through module
16
32
48
64
10 Gb/sec LAN pass-through module
16
32
48
64
10 Gb/sec DCB switch module
8
16
24
32
8 Gb/sec FC switch module
6
12
N/A
N/A
16 Gb/sec FC switch module
8
16
N/A
N/A
Switches, Indicators and Connectors
1 Gb/sec LAN Switch Module (20 ports)
Figure 1-34 1 Gb/sec LAN Switch Module (20 ports)
Table 1-17 1 Gb/sec LAN Switch Module (20 ports) Switches, Indicators
and Connectors
Location
1
Name
LAN ports 1 to 4
State
Green-On
Description
Link established.
Green-Blink Link communication.
Amber-On
Link failed.
2
Memory Card slot (MC) -
Slot for an SD memory card.
3
Access LED (ACC)
Green-On
The SD memory card is accessed.
4
Reset switch (RST)
-
Press and hold for five seconds to reset
the LAN switch module.
5
Power LED (PWR)
Green-On
Powered-on, normal operation.
6
Status1 LED (ST1)
Green-On
Normal operation.
Green-Blink Power-on diagnosis or software
activation.
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
1-29
Location
7
Name
Identify LED (LOCID)
State
Description
Red-Blink
Fault. Max. temperature limit exceeded
or other warning.
Red-On
Alarm.
Blue-On
The switch module is identified.
1 Gb/sec LAN Switch Module (40 ports)
Figure 1-35 1 Gb/sec LAN Switch Module (40 ports)
Table 1-18 1 Gb/sec LAN Switch Module Switches (40 ports), Indicators
and Connectors
Location
1
Name
LAN ports 1 to 8
State
Green-On
Description
Link established.
Green-Blink Link communication.
Amber-On
Link failed.
2
Memory Card slot (MC) -
Slot for an SD memory card.
3
Access LED (ACC)
Green-On
The SD memory card is accessed.
4
Reset switch (RST)
-
Press and hold for five seconds to reset
the LAN switch module.
5
Power LED (PWR)
Green-On
Powered-on, normal operation.
6
Status1 LED (ST1)
Green-On
Normal operation.
Green-Blink Power-on diagnosis or software
activation.
7
1-30
Identify LED (LOCID)
Red-Blink
Fault. Max. temperature limit exceeded
or other warning.
Red-On
Alarm.
Blue-On
The switch module is identified.
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
1/10 Gb/sec LAN Switch Module
Figure 1-36 1/10 Gb/sec LAN Switch Module
Table 1-19 1/10 Gb/sec LAN Switch Module Switches, Indicators and
Connectors
Location
1
Name
LAN ports 1 to 4
State
Green-On
Description
Link established.
Green-Blink Link communication.
Amber-On
Link failed.
-
Slots for 10GBASE-LR or 10GBASE-SR
transceivers. Each slot has both link and
activity LEDs to the side.
2
10GBASE-R slots
3
Memory Card slot (MC) -
Slot for an SD memory card.
4
Access LED (ACC)
Green-On
The SD memory card is accessed.
5
Reset switch (RST)
-
Press and hold for five seconds to reset
the LAN switch module.
6
LINK LED for XFP
Green-On
Link established.
Amber-On
Link failed.
7
TX/RX LED for XFP
Green-On
Link communication.
8
Power LED (PWR)
Green-On
Powered-on, normal operation.
9
Status1 LED (ST1)
Green-On
Normal operation.
Green-Blink Power-on diagnostics or firmware
activation.
10
Identify LED (LOCID)
Red-Blink
Fault. Max temperature limit exceeded
or other warning.
Red-On
Alarm.
Blue-On
The switch module is identified.
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
1-31
1 Gb/sec LAN Pass-through Module
Figure 1-37 1 Gb/sec LAN Pass-through Module
Table 1-20 1 Gb/sec LAN Pass-through Module Indicators and Connectors
Location
1
Name
LAN ports 0 to 15
State
Green-On
Description
Link established.
Green-Blink Link communication
Amber-On
No link.
2
Identify LED (LOCID) Blue-On
The LAN pass-through module is
identified.
3
Power LED (PWR)
Powered-on, normal operation.
Green-On
10 Gb/sec LAN Pass-through Module
Figure 1-38 10 Gb/sec LAN Pass-through Module
Table 1-21 10 Gb/sec LAN Pass-through Module Indicators and
Connectors
Location
1-32
Name
State
Description
1
LAN ports 0 to 15
-
By default these ports do not have
transceivers installed. The type of
transceiver varies according to
usage.
2
Power LED (PWR)
Green-On
Powered on normally.
3
Status 1 LED (ST1)
Green-On
Powered on.
Green-Blink
In initial diagnostics or in initial
setting.
Red-On
An error is detected.
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
Location
Name
State
Description
Red-Blink
Warning, such as beyond the
upper-limit temperature, is
detected.
4
Unique identification LED Blue-On
(UID)
The LAN pass-through module is
identified.
5
Port status LED
Green-On
Link established.
Green-Blink
Link communication
Amber-On
Link is not established.
Green / Amber In initial diagnostics or in initial
blink by turns setting.
Brocade 10 Gb/sec DCB Switch Module
Figure 1-39 Brocade 10 Gb/sec DCB Switch Module
Table 1-22 Brocade 10 Gb/sec DCB Switch Module Switches, Indicators
and Connectors
Location
Name
State
Description
1
Identify LED (LOCID)
Blue-On
The switch module is identified
2
Power LED (PWR)
Green-On
Powered-on, normal operation.
3
Status LED
Green-On
Normal operation.
Green-Blink Power-on diagnostics or firmware
activation.
Amber-On
Fail.
Amber-Blink Warning.
4
Uplink port status LED1 Amber-On
Signal or communication received, but
not on line.
Amber-Blink Slow blink: Port disabled.
Rapid blink: Port failed.
5
Uplink port status LED2 Green-On
Online.
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
1-33
Location
Name
State
Description
Green-Blink Irregular blink: Link communication.
Slow blink: LAN interface online, but
segmented.
Rapid Blink: Diagnostic internal loop
back.
6
Uplink ports:
-
By default these ports do not have
transceivers installed. The type of
transceiver varies according to usage.
1-8
Brocade 8 Gb/sec Fibre Channel Switch Module
Figure 1-40 Brocade 8 Gb/sec Fibre Channel Switch Module
Table 1-23 Brocade 8 Gb/sec Fibre Channel Switch Module Switches,
Indicators and Connectors
Location
Name
State
Description
1
Identify LED (LOCID)
Blue-On
The switch module is identified.
2
Power LED (PWR)
Green-On
Powered-on, normal operation.
3
Status LED
Green-On
Normal operation.
Green-Blink Power-on diagnostics or firmware
activation.
Red-Blink
Fault. Max temperature limit exceeded
or other warning.
Red-On
Alarm.
4
FC ports: 0 - 5
-
SFP+ module slots for connection of
fibre channel cables
5
Uplink port status LED1
Amber-On
Signal or communication received, but
not online.
Amber-Blink Slow blink: The port is disabled.
Rapid blink: The port has failed.
6
1-34
Uplink port status LED2
Green-On
FC port is online.
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
Location
Name
State
Description
Green-Blink Slow blink: The FC port is online but
segmented.
Rapid blink: Diagnostic internal loop
back.
7
USB port
-
For an optional USB memory device
dedicated to fibre channel switch
module.
Do not connect any other type of
device.
8
Management LAN port
-
Management LAN port for the fibre
channel switch module.
This LAN port is disabled by default.
9
Management LAN port
status LED1
Amber-On
Management LAN port is online.
10
Management LAN port
status LED2
Green-On
1000 Mbps full duplex.
Brocade 16 Gb/sec Fibre Channel Switch Module
Figure 1-41 Brocade 16 Gb/sec Fibre Channel Switch Module
Table 1-24 Brocade 16 Gb/sec Fibre Channel Switch Module Switches,
Indicators and Connectors
Location
Name
State
Description
1
Identify LED (LOCID)
Blue-On
The switch module is identified.
2
Power LED (PWR)
Green-On
Powered-on, normal operation.
3
Status LED
Green-On
Normal operation.
Green-Blink Power-on diagnostics or firmware
activation.
Amber-On
Fault.
Amber-Blink Alarm.
4
Uplink port status LED1 Green-On
FC port is online.
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
1-35
Location
Name
State
Description
Green-Blink Random blink: In link communication
Slow blink: The FC port is online but
segmented.
Rapid blink: Diagnostic internal loop
back.
5
Uplink port status LED2 Amber-On
Signal or communication received, but
not online.
Amber-Blink Slow blink: The port is disabled.
Rapid blink: The port has failed.
6
FC ports: 16 - 23
-
External ports
Power Supply Module
This section describes the power supply module.
Indicator and connector
Figure 1-42 Power Supply Module
Table 1-25 Power Supply Module Indicators
Location
1
Name
State
POWER LED (PWR) Green-On
Description
12 V main power on.
Green-Blink 12 V main power off, but AC power is
present.
Amber-On
Fail or system shutdown.
Amber-Blink No AC power to this power supply, but
others are supplied with AC power.
2
1-36
Inlet
-
IEC60320-C20 power inlet.
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
Fan Module
This section describes the fan module.
Indicator
Figure 1-43 Fan Module
Table 1-26 Fan Module Indicators
Location
1
Name
Status LED
State
Description
Green-On
Normal operation.
Amber-On
Fail.
User Maintenance
Customer replaceable units can be installed or replaced by the user while still
under warranty.
The following shows customer replaceable units (CRU).
Table 1-27 Customer replaceable units (CRU)
Location
Server chassis
Replaceable units
Server blade
Shelf
Management module
Lithium battery
Switch module
SFP+
Fan module
Power supply module
LCD touch console
Front panel
KVM/USB cable
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
1-37
Location
Server blade
Replaceable units
HDD/SSD
DIMM
DIMM filler
Air Duct
HDD backplane
Mezzanine card
Lithium battery
USB memory (LPAR manager)
For more information, see;
•
Hitachi Compute Blade 500 Series System Service Manual
Note: Only install or replace units that are specifically allowed for customer
replacement. All maintenance must be performed according to;
•
1-38
Hitachi Compute Blade 500 Series System Service Manual
System Overview
Hitachi Compute Blade 500 Series System Overview Guide
2
Specification
This chapter describes the specifications of the system interface.
□ System Unit Specifications
□ Interface Port Pin-outs
Specification
Hitachi Compute Blade 500 Series System Overview Guide
2-1
System Unit Specifications
This section describes specifications for the system unit.
Server Chassis Specifications
The following table provides the server chassis specifications.
Table 2-1 Server Chassis Specifications
Items
Specifications
Enclosure
Number of modules
that can be installed
Rack mount type 6 U
Server blades
Up to 8 blades
Management modules
Up to 2 modules
Switch
modules
Up to 4 modules
Switch bays #0 and #1
Up to 2 modules
Same type of modules
must be installed.
FC switch module is not
available.
Switch bays #2 and #3
Up to 2 modules
Same type of modules
must be installed.
Power supply
modules
Power supply bays
Redundant
configuration
Up to 4 units
Rated at 100 1+1 or 2+1 or 2+2 or 3+1
Vac
Rated at 200 1+1 or 2+1 or 2+2 or 3+1
Vac
Power input
Fan modules
100 Vac: 3597 W / 200
Vac: 5140 W
6 modules as standard (N
+M modules
configuration)
External dimensions (W x D x H: mm)/number of units according to the EIA
standard
447 x 791 x 262 / 6 U
Mass
Maximum: 130 kg
(with all modules
installed; including rack
rails)
Power source
Input voltage (Frequency)
Single Phase AC
100-120 V / 200-240 V
(50-60 Hz)
Environmental
requirements
2-2
Power consumption (Maximum)1
4678 W
Temperature
5 to 40°C [Non-operating:
-10 to 43 °C]3
Specification
Hitachi Compute Blade 500 Series System Overview Guide
Items
Specifications
Humidity
20 to 80 % [Nonoperating: 10 to 90 %]
EMC regulations
FCC, ICES, EN55022,
EN55024, EN61000, KC
KN24,
KC KN22, C-Tick, GOST,
BSMI, CCC
Noise
60db (A) or lower2
Notes:
1.
This value is the rating of the server chassis. Actual power consumption depends on the
configuration of the server blades.
2.
This equipment controls fan rotation according to the temperature of the inlet air. Under the
following conditions, the noise level may exceed this value.
3.
¢
Inlet air temperature exceeds 25°C.
¢
CPU is under heavy load.
¢
Fan fails.
¢
CB 520H B2 server blade has E5-2637v2 installed.
5 to 30°C [Non-operating: -10 to 43°C] for CB 520H B2 with CPU E5-2637v2 installed.
5 to 35°C [Non-operating: -10 to 43°C] for CB 520H B3 with CPUE5-2699v3, E5-2697v3, E5-2667v3
and E5-2637v3 installed.
Server Blade Specifications
The following table provides specifications for server blades.
Table 2-2 Xeon Server Blade CPU specification (CB 540A A1/B1)
Items
Specifications
Supported CPU
E5-4650
E5-4610
E5-4603
Number of Cores
8C
6C
4C
CPU frequency
2.7 GHz
2.4 GHz
2.0 GHz
QPI frequency
8.0 GT/s
7.2 GT/s
6.4 GT/s
L3 cache
20 M
15 M
10 M
TDP
130 W
95 W
95 W
Number of CPUs
Maximum: 4
Table 2-3 Xeon Server Blade other specification (CB 540A A1/B1)
Items
Main memory
DIMM type (per slot)
Specifications
DDR3 RDIMM, 2 / 4 / 8 / 16 / 32 GB; LR-DIMM
32 GB
Specification
Hitachi Compute Blade 500 Series System Overview Guide
2-3
Items
Specifications
Operating mode
Independent channel mode, Rank sparing
mode, Mirrored channel mode
Number of slots
48
Memory capacity
Maximum: 1024 GB (RDIMM 32 GB x 32);
1536 GB (LR-DIMM 32 GB x 48)
HDD/SSD
I/O
Memory frequency
800 / 1066 / 1333 / 1600 MT/s
Number of HDDs
Maximum: 2
Capacity1
Maximum: 1.8 TB
Internal disk
I/F
VGA
Onboard LAN2
Management
function
Controller
LSI SAS 2004 / LSI SAS 2008
I/F
SAS
Number of I/F
Maximum: 2 (2.5 inch SAS HDD, SSD)
RAID function
RAID 0.1
Resolution
640x400 - 1680x1050
Refresh rate
60 - 85 Hz
Bit per pixel
8, 16, 32
Midplane I/F
10 Gb/1 Gb Ethernet 2 port
Function
Wake on LAN, PXE boot, iSCSI
Remote console
Supported
COM
Serial redirection
DC input supply voltage
DC + 12 V
Front interface
USB
1 (USB2.0)
KVM connector
1 (VGA / COM / USB2.0 / 2port)
DCMI (Data Center Management Interface)
Not supported
Power consumption
1103 W
External dimension (W x D x H: mm)
435.3 x 492.7 x 51.1
Mass
Maximum: 13.3 kg
Notes:
1.
Hard disk drive capacity is calculated assuming that 1 GB is equal to 109 bytes.
2.
A1 model does not come with the onboard LAN.
Table 2-4 Xeon Server Blade CPU specification (CB 520H A1/B1) - 1
Items
Specifications
Supported CPU
E5-2680
E5-2670
E5-2640
Number of Cores
8C
8C
6C
2-4
Specification
Hitachi Compute Blade 500 Series System Overview Guide
Items
Specifications
CPU frequency
2.7 GHz
2.6 GHz
2.5 GHz
QPI frequency
8.0 GT/s
8.0 GT/s
7.2 GT/s
L3 cache
20 M
20 M
15 M
TDP
130 W
115 W
95 W
Number of CPUs
Maximum: 2
Table 2-5 Xeon Server Blade CPU specification (CB 520H A1/B1) - 2
Items
Specifications
Supported CPU
E5-2620
E5-2603
E5-2630L
Number of Cores
6C
4C
6C
CPU frequency
2 GHz
1.8 GHz
2 GHz
QPI frequency
7.2 GT/s
6.4 GT/s
7.2 GT/s
L3 cache
15 M
10 M
15 M
TDP
95 W
80 W
60 W
Number of CPUs
Maximum: 2
Table 2-6 Xeon Server Blade other specification (CB 520H A1/B1)
Items
Main memory
HDD/SSD
I/O
Specifications
DIMM type (per slot)
DDR3 RDIMM, 2 / 4 / 8 / 16 / 32 GB; LR DIMM 32 GB
Operating mode
Independent channel mode, Rank sparing mode,
Mirrored channel mode
Number of slots
24
Memory capacity
Maximum: 512 GB (32 GB x 16); 768 GB (LR-DIMM 32
GB x 24)
Memory frequency
800 / 1066 / 1333 / 1600 MT/s
Number of HDDs
Maximum: 2
Capacity1
Maximum: 1.8 TB
Internal disk Controller
I/F
I/F
LSI SAS 2004 / LSI SAS 2008
VGA
SAS
Number of I/F
Maximum: 2 (2.5 inch SAS HDD, SSD)
RAID function
RAID 0.1
Resolution
640x400 - 1680x1050
Refresh rate
60 - 85 Hz
Bit per pixel
8, 16, 32
Specification
Hitachi Compute Blade 500 Series System Overview Guide
2-5
Items
Management
function
Specifications
Internal USB port
USB2.0 x 2port (For LPAR manager)
Onboard
LAN2
Midplane I/F
10 Gb/1 Gb Ethernet 2 port
Function
Wake on LAN, PXE boot, iSCSI
Remote console
Supported
COM
Serial redirection
DC input supply voltage
DC + 12 V
Front interface
USB
1 (USB2.0)
KVM connector
1 (VGA / COM / USB2.0 / 2port)
DCMI (Data Center Management Interface)
Not supported
Power consumption
529 W
External dimension (W x D x H: mm)
215.4 x 492.7 x 51.1
Mass
Maximum: 7.1 kg
Notes:
1.
Hard disk drive capacity is calculated assuming that 1 GB is equal to 109 bytes.
2.
A1 model does not come with the onboard LAN.
Table 2-7 Xeon Server Blade CPU specification (CB 520H B2) - 1
Items
Specifications
Supported CPU
E5-2643 v2
E5-2697 v2
E5-2690 v2
E5-2650 v2
Number of Cores
6C
12 C
10 C
8C
CPU frequency
3.5 GHz
2.7 GHz
3.0 GHz
2.6 GHz
QPI frequency
8.0 GT/s
8.0 GT/s
8.0 GT/s
8.0 GT/s
L3 cache
25 M
30 M
25 M
20 M
TDP
130 W
130 W
130 W
95 W
Number of CPUs
Maximum: 2
Table 2-8 Xeon Server Blade CPU specification (CB 520H B2) - 2
Items
Specifications
Supported CPU
E5-2630 v2
E5-2603 v2
E5-2637 v21
E5-2670 v2
Number of Cores
6C
4C
4C
10 C
CPU frequency
2.6 GHz
1.8 GHz
3.5 GHz
2.5 GHz
QPI frequency
7.2 GT/s
6.4 GT/s
8.0 GT/s
8.0 GT/s
L3 cache
15 M
10 M
15 M
25 M
TDP
80 W
80 W
130 W
115 W
2-6
Specification
Hitachi Compute Blade 500 Series System Overview Guide
Items
Specifications
Number of CPUs
Maximum: 2
Notes:
1.
Inlet air temperature is restricted to 5 to 30°C [Non-operating: -10 to 43°C].
Table 2-9 Xeon Server Blade other specification (CB 520H B2)
Items
Main memory
Specifications
DIMM type (per slot)
DDR3 RDIMM, 4 / 8 / 16 GB
LR-DIMM 32 GB
HDD/SSD
I/O
Operating mode
Independent channel mode, Rank sparing mode, Mirrored
channel mode
Number of slots
24
Memory capacity
Maximum: 384 GB (RDIMM 16 GB x 24); 768 GB (LRDIMM 32 GB x 24)
Memory frequency
800 / 1066 / 1333 / 1600 / 1866 MT/s
Number of HDDs
Maximum: 2
Capacity1
Maximum: 2.4 TB
Internal
disk I/F
VGA
Onboard
LAN
Management
function
Controller
LSI SAS 2008
I/F
SAS
Number of
I/F
Maximum: 2 (2.5 inch SAS HDD, SSD)
RAID
function
RAID 0, RAID 1
Resolution
640x400 - 1680x1050
Refresh rate
60 - 85 Hz
Bit per pixel
8, 16, 32
Midplane I/F
10 GB/1 GB Ethernet 2 port
Function
Wake on LAN, PXE boot, iSCSI
Remote console
Supported
COM
Serial redirection
DC input supply voltage
DC + 12 V
Front interface
USB
1 (USB2.0)
KVM connector
1 (VGA / COM / USB2.0 / 2 port)
DCMI (Data Center Management Interface)
Not supported
Power consumption
613 W
External dimension (W x D x H: mm)
215.4 x 492.7 x 51.1
Mass
Maximum: 7.1 kg
Specification
Hitachi Compute Blade 500 Series System Overview Guide
2-7
Items
Specifications
Notes:
1.
Hard disk drive capacity is calculated assuming that 1 GB is equal to 109 bytes.
Table 2-10 Xeon Server Blade CPU specification (CB 520H B3) - 1
Items
Specifications
Supported CPUs
E5-2699 v31
E5-2698 v3
E5-2697 v31
E5-2690 v3
E5-2660 v3
E5-2640 v3
Number of cores
18 C
16 C
14 C
12 C
10 C
8C
CPU frequency
2.3 GHz
2.3 GHz
2.6 GHz
2.6 GHz
2.6 GHz
2.6 GHz
QPI frequency
9.6 GT/s
9.6 GT/s
9.6 GT/s
9.6 GT/s
9.6 GT/s
8.0 GT/s
L3 Cache
45 MB
40 MB
35 MB
30 MB
25 MB
20 MB
TDP
145 W
135 W
145 W
135 W
105 W
90 W
Number of CPUs
Maximum: 2
Notes:
1.
Inlet air temperature is restricted to 5 to 35°C [Non-operating: -10 to 43°C].
Table 2-11 Xeon Server Blade CPU specification (CB 520H B3) - 2
Items
Specifications
Supported CPUs
E5-2620 v3
E5-2603 v3
E5-2667 v31
E5-2637 v31
Number of cores
6C
6C
8C
4C
CPU frequency
2.4 GHz
1.6 GHz
3.2 GHz
3.5 GHz
QPI frequency
8.0 GT/s
6.4 GT/s
9.6 GT/s
9.6 GT/s
L3 Cache
15 MB
15 MB
20 MB
15 MB
TDP
85 W
85 W
135 W
135 W
Number of CPUs
Maximum: 2
Notes:
1.
Inlet air temperature is restricted to 5 to 35°C [Non-operating: -10 to 43°C].
Table 2-12 Xeon Server Blade other specification (CB 520H B3)
Items
Main Memory
DIMM type (per slot)
Specifications
DDR4 RDIMM 8, 16 GB
LRDIMM 32 GB
Operating mode
Independent Channel Mode, Rank Sparing Mode,
Mirrored Channel Mode
Number of slots
2-8
24
Specification
Hitachi Compute Blade 500 Series System Overview Guide
Items
Specifications
Maximum capacity
RDIMM: 384 GB (16 GB x 24)
LRDIMM: 768 GB(32 GB x 24)
HDD / SSD
I/O
Memory frequency
2133, 1866, 1600 MT/s
Number of HDDs
Maximum: 2
Capacity1
Maximum: 2.4 TB
Internal disk I/F
Controller
LSI SAS 3004
I/F
SAS (SATA is not supported)
Number of I/F Maximum: 2 (2.5 inch SAS HDD, SSD)
RAID function RAID 0, 1
VGA
Resolution
640 x 400 - 1680 x 1050
Refresh rate
60 - 85 Hz
Bit per pixel
8, 16, 32
Internal SD card on Daughter card 1 (SD card slots per Daughter card: 2)
Onboard LAN
Management
functionality
Midplane I/F
4-port 10 Gb Ethernet
(Only if mezzanine Functions
card 1 is not
installed)
Wake on LAN, PXE boot, iSCSI, FCoE
Remote console
Supported
COM
Serial redirection
DC input supply voltage
DC +12V
Front interface
USB
1 (USB 3.0)
KVM connector
1 (VGA, COM, 2-port USB 2.0)
DCMI (Data Center Management Interface)
Supported
Power consumption
517 W
External dimensions (W x D x H: mm)
215.4 x 500.6 x 51.1
Mass
7.1 kg
Notes:
1.
Hard disk drive capacity is calculated assuming that 1 GB is equal to 109 bytes.
Table 2-13 Xeon Server Blade CPU specification (CB 520A A1)
Items
Specifications
Supported CPU
E5-2470
E5-2440
E5-2420
E5-2403
E5-2430L
Number of Cores
8C
6C
6C
4C
6C
CPU frequency
2.3 GHz
2.4 GHz
1.9 GHz
1.8 GHz
2 GHz
QPI frequency
8.0 GT/s
7.2 GT/s
7.2 GT/s
6.4 GT/s
7.2 GT/s
Specification
Hitachi Compute Blade 500 Series System Overview Guide
2-9
Items
Specifications
L3 cache
20 M
15 M
15 M
10 M
15 M
TDP
95 W
95 W
95 W
80 W
60 W
Number of CPUs
Maximum: 2
Table 2-14 Xeon Server Blade other specification (CB 520A A1)
Items
Main memory
HDD/SSD
I/O
DIMM type (per slot)
DDR3 RDIMM, 2 / 4 / 8 / 16 / 32 GB
Operating mode
Independent channel mode, Rank sparing mode,
Mirrored channel mode
Number of slots
12
Memory capacity
Maximum: 384 GB (32 GB x 12)
Memory frequency
800 / 1066 / 1333 / 1600 MT/s
Number of HDDs
Maximum: 2
Capacity1
Maximum: 2 TB
Internal disk
I/F
VGA
Management
function
Specifications
Controller
LSI SAS 2004 / LSI SAS 2008 or Patsburg
I/F
SAS/SATA
Number of I/F
Maximum: 2 (2.5 inch SAS HDD, SATA HDD, SSD)
RAID function
RAID 0.1
Resolution
640x400 - 1680x1050
Refresh rate
60 - 85 Hz
Bit per pixel
8, 16, 32
Internal USB port
USB2.0 x 2port (For LPAR manager)
Remote console
Supported
COM
Serial redirection
DC input supply voltage
DC + 12 V
Front interface
USB
1 (USB2.0)
KVM connector
1 (VGA / COM / USB2.0 / 2port)
DCMI (Data Center Management Interface)
Not supported
Power consumption
396 W
External dimension (W x D x H: mm)
215.4 x 492.7 x 51.1
Mass
Maximum: 6.2 kg
Notes:
1.
Hard disk drive capacity is calculated assuming that 1 GB is equal to 109 bytes.
2-10
Specification
Hitachi Compute Blade 500 Series System Overview Guide
Table 2-15 Xeon Server Blade CPU specification (CB 520X B1) - 1
Items
Specifications
Supported CPU
E7-4820v2
E7-4860v2
E7-4880v2
E7-8880v2
Number of Cores
8C
12 C
15 C
15 C
CPU frequency
2.0 GHz
2.6 GHz
2.5 GHz
2.5 GHz
QPI frequency
8.0 GT/s
8.0 GT/s
8.0 GT/s
8.0 GT/s
L3 cache
12 M
30 M
37.5 M
37.5 M
TDP
105 W
130 W
130 W
130 W
Number of CPUs
Maximum: 2
Table 2-16 Xeon Server Blade CPU specification (CB 520X B1) - 2
Items
Specifications
Supported CPU
E7-8890v2
E7-8891v2
Number of Cores
15 C
10 C
CPU frequency
2.8 GHz
3.2 GHz
QPI frequency
8.0 GT/s
8.0 GT/s
L3 cache
37.5 M
37.5 M
TDP
155 W
155 W
Number of CPUs
Maximum: 2
Table 2-17 Xeon Server Blade other specification (CB 520X B1)
Items
Main memory
Specifications
DIMM type (per slot)
DDR3 RDIMM, 8 / 16 GB; LR DIMM 32 GB
Operating mode
Independent Mode (Default), Lockstep Mode, Rank
Sparing Mode, Mirrored Memory Mode
Number of slots
48
Memory capacity
Maximum: 1536 GB (32 GB x 48)
Memory frequency
1066 / 1333 / 1600 MT/s
Inter-blade SMP (Symmetric Multi Processing)
2-blade SMP / 4-blade SMP
HDD/SSD
Number of HDDs
Maximum: 2
Capacity1
Maximum: 2.4 TB
I/O
Internal disk
I/F
Controller
LSI SAS 3004
I/F
SAS
Number of I/F
Maximum: 2
RAID function
RAID 0.1
Specification
Hitachi Compute Blade 500 Series System Overview Guide
2-11
Items
VGA
Specifications
Resolution
640x400 - 1680x1050
Refresh rate
60 - 85 Hz
Bit per pixel
8, 16, 32
Internal USB port
USB2.0 x 2port (For LPAR manager)
Onboard LAN Midplane I/F
10 Gb Ethernet 4 port
Function
Management
function
Wake on LAN, PXE boot, iSCSI, FCoE
Remote console
Supported
COM
Serial redirection
DC input supply voltage
DC + 12 V
Front interface
USB
1 (USB 3.0)2
KVM connector
1 (VGA / COM / USB2.0 / 2port)2
DCMI (Data Center Management Interface)
Not supported
Power consumption
738 W
External dimension (W x D x H: mm)
435.3 x 492.7 x 55.5 (2S)
Mass
Maximum: 13.8 kg3
Notes:
1.
Hard disk drive capacity is calculated assuming that 1 GB is equal to 109 bytes.
2.
In SMP configuration between blades, VGA and COM are not available and only USB port is available
on non-primary server blades.
3.
The Mass of a server blade includes that of SMP connection board.
Table 2-18 Xeon Server Blade CPU specification (CB 520X B2)
Items
Specifications
Supported CPU
E7-8880v3
E7-8890v3
E7-8893v3
Number of Cores
18 C
18 C
4C
CPU frequency
2.3 GHz
2.5 GHz
3.2 GHz
QPI frequency
9.6 GT/s
9.6 GT/s
9.6 GT/s
L3 cache
45 M
45 M
45 M
TDP
150 W
165 W
140 W
Number of CPUs
Maximum: 2
Table 2-19 Xeon Server Blade other specification (CB 520X B2)
Items
Main memory
2-12
DIMM type (per slot)
Specifications
DDR4 RDIMM: 8 GB, 16 GB, 32 GB
Specification
Hitachi Compute Blade 500 Series System Overview Guide
Items
Specifications
Operating mode
Independent Mode (Default), Lockstep Mode, Rank
Sparing Mode, Mirrored Memory Mode
Number of slots
48
Memory capacity
Maximum: 1,536 GB (32 GB x 48)
Memory frequency
1333 / 1600 / 1866 MT/s
Inter-blade SMP (Symmetric Multi Processing)
2-blade SMP / 4-blade SMP
HDD/SSD
Number of HDDs
Maximum: 2
Capacity1
Maximum: 2.4 TB
I/O
Internal disk
I/F
VGA
Management
function
Controller
LSI SAS 3004
I/F
SAS
Number of I/F
Maximum: 2
RAID function
RAID 0.1
Resolution
640x400 - 1680x1050
Refresh rate
60 - 85 Hz
Bit per pixel
8, 16, 32
Internal USB port
USB2.0 x 2port (For LPAR manager)
Onboard LAN
Midplane I/F
10 Gb Ethernet 4 port
Function
Wake on LAN, PXE boot, iSCSI, FCoE
Remote console
Supported
COM
Serial redirection
DC input supply voltage
DC + 12 V
Front interface
USB
1 (USB 3.0)2
KVM connector
1 (VGA / COM / USB2.0 / 2port)2
DCMI (Data Center Management Interface)
Supported
Power consumption
722 W
External dimension (W x D x H: mm)
435.3 x 492.7 x 55.5 (2S)
Mass
Maximum: 13.8 kg3
Notes:
1.
Hard disk drive capacity is calculated assuming that 1 GB is equal to 109 bytes.
2.
In SMP configuration between blades, VGA and COM are not available and only USB port is available
on non-primary server blades.
3.
The Mass of a server blade includes that of SMP connection board.
Specification
Hitachi Compute Blade 500 Series System Overview Guide
2-13
Table 2-20 Server Blade specification (Storage Expansion model)
Items
HDD/SSD
I/O
Specifications
Number of HDDs
Maximum: 6
Capacity1
Maximum: 5.4 TB
Internal disk I/F
Controller
LSI SAS 2208
I/F
SAS
Number of I/F
Maximum: 6 (2.5 inch SAS HDD, SSD)
RAID function
RAID 0.1, 5, 10.6
DC input supply voltage
DC + 12 V
Front interface
1 port (4 lanes)
SAS
Power consumption
93 W2
External dimension (W x D x H: mm)
435.3 x 492.7 x 55.5
Mass
Maximum: 8.1 kg3
Notes:
1.
Hard disk drive capacity is calculated assuming that 1 GB is equal to 109 bytes.
2.
This is a value of single storage expansion blade.
3.
This is a value of storage expansion blade including the shelf parts.
Table 2-21 Server Blade specification (PCI Expansion model)
Items
I/O PCI slot
Specifications
Interface
PCI Express
Number of slots
Maximum: 6 slots
- Full height, Full length slots: 2 (PCI expansion slot
0/1)
- Low profile (MD2) slots: 4 (PCI expansion slot
2/3/4/5)
Slot specifications PCI expansion slot 0
Electrical x8/Physical x8; Maximum: 25 W
PCI expansion slot 1
Electrical x8/Physical x8; Maximum: 25 W
PCI expansion slot 2/slot 3 - Electrical x8/Physical x8; Maximum: 25 W
(PCI blade card adapter x8 L/P)
- Electrical x4/Physical x8; Maximum: 25 W
(PCI blade card adapter x4 L/P)
PCI expansion slot 4/slot 5 Electrical x4/Physical x8; Maximum: 25 W
DC input supply voltage
DC + 12 V
Power consumption
294 W1
External dimensions (W x D x H: mm)
215.4 x 492.7 x 51.11
2-14
Specification
Hitachi Compute Blade 500 Series System Overview Guide
Items
Mass
Specifications
Maximum: 9.11 kg2
Notes:
1.
This value is for a single PCI expansion blade.
2.
This value includes the shelf for a PCI expansion blade.
Management Module Specifications
The following table provides the management module specifications.
Table 2-22 Management Module specifications
Items
External ports
Specifications
Management LAN
1000BASE-T/100BASE-TX/10BASE-T x 1 port
1000BASE-T/100BASE-TX/10BASE-T x 1 port
1000BASE-T/100BASE-TX/10BASE-T x 1 port
Serial
Indicators (LED)
1 port
6 LEDs
(Power / Primary / Alarm / Remote / Identify /
Heartbeat)
Console functions
Remote maintenance
functions
CLI console
A CLI (Command Line Interface) provided to the user
for system operation and management.
Web console (GUI)
A web console GUI provided to the user for system
operation and management.
E-mail notification
E-mail notification of error information (Alert).
Remote maintenance Remote maintenance functionality linked to the
ASSIST remote maintenance system.
Firmware update
Available
External dimensions (W x D x H: mm)
146 x 252 x 25
Mass
0.6 kg
Switch Module Specifications
The following table provides specifications for switch modules.
Specification
Hitachi Compute Blade 500 Series System Overview Guide
2-15
Table 2-23 LAN Switch Module specifications
Specifications
Items
Ports
1 Gb/sec LAN switch
module (40 ports)
External
10/100/1000BASE-T x 8
1 Gb/sec LAN
switch module
(20 ports)
10/100/1000BASE-T x 4
Internal
Connector
10GBASE-R x 2
1000BASE-Serdes x 32
1000BASE-Serdes x 16
(Server blade I/F)
(Server blade I/F)
10/100/1000BASE-T x
4
RJ-45
10 G
-
Console / management ports
1/10-Gb/sec
LAN switch
module
XFP
10/100 Ethernet (RJ-45)
Serial port (RS-232C)
In-band through the management module
Layer-2
functions
Layer-3
functions
Network
functions
VLAN
Port VLAN, Tag-VLAN (IEEE802.1Q),
Protocol VLAN, MAC-VLAN, Tag conversion
Spanning tree protocol
STP (IEEE802.1D), RST P(IEEE802.1w), PVST+,
MSTP(IEEE802.1s)
Other functions
IGMP, snooping, MLD snooping, Link aggregation, jumbo frame,
IEEE802.3ah / UDLD, Ring protocol
IPv4
routing
Uni-cast
Static, RIP, RIP2, OSPF, BGP4
Multi-cast
IGMPv2/v3, PIM-SM, PIM-SSM
IPv6
routing
Uni-cast
Static, RIPing, OSPFv3, BGP4+
Multi-cast
MLDv1/v2, PIM-SM, PIM-SSM
Security functions
Filter (L2 / IPv4 / IPv6 / L4), port to port relay interruption,
IEEE802.1X authentication
QoS
Flow detection (L2 / IPv4 / IPv6 / L4), band monitoring (rate
control), marking (DSCP / User Priority), Priority control (Flow
base, User priority mapping), disposal control (taildrop), shaper
(eight classes, port band control), scheduling (PQ, WRR, PQ+DRR,
WFQ), Diff-serv, IEEE802.1p
High reliability,
Advanced operation
Load balancing (IPv4 / IPv6), VRRP (IPv4 / IPv6),
Static polling, VRRP polling,
Link aggregation (IEEE802.3ad), GSRP,
Graceful Restart (Helper), Storm control
L2-VPN
VLAN tunneling
Operation management functions
2-16
SNMPv1 / v2 / v3, MIB II, IPv6MIB, RMON, syslog, ping,
traceroute, SSH, telnet, ftp, tftp, NTP, IPv4DHCP server/relay,
PrefixDelegation, LLDP, OADP, port mirroring, RADIUS, TACACS+,
Uplink failover, (Dynamic) Flow statistics/information (sFlow)
Specification
Hitachi Compute Blade 500 Series System Overview Guide
Specifications
Items
1 Gb/sec LAN switch
module (40 ports)
1 Gb/sec LAN
switch module
(20 ports)
1/10-Gb/sec
LAN switch
module
Power supply
12 V
External dimensions
161 x 243 x 32.3 (excluding backplane connector)
(W x D x H: mm)
Mass
1.2 kg
1.40 kg
Table 2-24 1 Gb/sec LAN Pass-through Module specifications
Items
Ports
Specifications
Internal
1-Gb/sec Serdes x 16
External
Fixed at 1000BASE-T x 16
Outside
Fixed at Full Duplex
Connector
RJ-45
Power supply
12 V
External dimensions (W x D x H: mm)
161 x 252 x 32.3
Mass
1.5 kg
Table 2-25 10 Gb/sec LAN Pass-through Module specifications
Items
Ports
Specifications
Internal
10 Gb KR x 16 ports (server blade interface)
External
SFP+ optical transceiver (10 Gb) x 16 ports
Connector
SFP+ (10 Gb)
Power supply
12 V
External dimensions (W x D x H: mm)
161 x 252 x 32.3
Mass
1.7 kg (SFP+ optical transceiver x 16 ports)
Table 2-26 Brocade 10 Gb/sec DCB Switch Module specifications
Items
Specifications
Link speed
10 Gbps, 1 Gbps
Ethernet
Flow control (802.3x), Jumbo frame
Layer 2
Function port VLAN, Tag-VLAN (IEEE 802.1Q), Protocol VLAN, MAC-VLANSTP
(IEEE 802.1D), RSTP (IEEE 802.1w),
PVST+, MSTP (IEEE 802.1s)
link aggregation (static, IEEE 802.3ad), uplink-failover
Specification
Hitachi Compute Blade 500 Series System Overview Guide
2-17
Items
Specifications
IGMP V2/V3 snooping, Storm Control
Security
ACLs (standard, VLAN-based, Port-based), IEEE 802.1X,
Radius, TACACS+
QoS
8 Class Queue, CoS, Priority Queue, DWRR
Management
telnet, ftp, IPv4 SNMP (v1/v2), Ping, tracert, Cisco like CLI
CEE (Converged
Enhanced Ethernet)
Priority-based Flow Control(PFC) – IEEE 802.1Qbb
Enhanced Transmission Selection (ETS) – IEEE 802.1Qaz
Data Center Bridging eXchange (DCBX) – IEEE DCB
High availability
Function associated with LAN controller redundancy (failover association),
hot-plug replacement,
configuration backup
Table 2-27 Brocade 8 Gb/sec Fibre Channel Switch Module specifications
Items
Specifications
FCSW component
Brocade 5460
Fibre channel ports
Minimum:
12 ports, internal and/or external, assigned as desired.
Maximum:
16 internal ports (Serdes interfaces to the server blades)
6 external ports
Supported line speeds
2.125 Gb/sec line speed, full duplex,
4.25 Gb/sec line speed, full duplex,
8.5 Gb/sec line speed, full duplex
Total bandwidth
374 Gb/sec
22 ports x 8.5 Gb/sec (line speed) x 2 (full duplex)
Fabric latency
Fibre channel
specification
700 ns (8 Gb/sec with cut-through routing)
Supported standards Fibre channel specification
Service classes
Class 2, class 3, class F
Maximum frame size
2112 byte payload
Data traffic
Unicast, multicast, broadcast
Media type
8 Gb SFP+, LC connector, short-wave laser
Maximum distance:
500 m at 1 Gb/sec; 300 m at 2 Gb/sec;
150 m at 4 Gb/sec; 50 m at 8 Gb/sec
Scalability
Full fabric architecture with up to 239 switches
Console / management ports
10/100 Ethernet (RJ-45)
Serial port (RS-232C)
2-18
Specification
Hitachi Compute Blade 500 Series System Overview Guide
Items
Specifications
In-band through the management module
Fabric service
Standard
Fabric service
Optional
Ports On Demand (POD)
(at additional
charge)
Fabric Watch
ISL Trunking
Hardware options
SFP+ (for adding one external port)
USB memory (for updating firmware; backing up and
restoring configuration)
These functions are also available through FTP server
without this option.
Operation management
SNMPv1, syslog, telnet, http, ftp
Power supply
12 V
External dimensions (W x D x H: mm)
161 x 252 x 32.3
Mass
1.5 kg (including SFP+)
Table 2-28 Brocade 16 Gb/sec Fibre Channel Switch Module specifications
Items
Specifications
FCSW component
Brocade 6546
Fibre channel ports
Minimum:
12 ports, internal and/or external, assigned as desired.
Maximum:
16 internal ports (Serdes interfaces to the server blades)
8 external ports
Supported line speeds
4.25 Gb/sec line speed, full duplex,
8.5 Gb/sec line speed, full duplex,
14.025 Gb/sec line speed, full duplex
Total bandwidth
673 Gb/sec
24 ports x 14.025 Gb/sec (line speed) x 2 (full duplex)
Fabric latency
Fibre channel
specification
700 ns (16 Gb/sec with cut-through routing)
Supported
standards
Fibre channel specification
Service classes
Class 2, class 3, class F
Maximum frame size
2112 byte payload
Data traffic
Unicast, multicast, broadcast
Media type
16 Gb SFP+, LC connector, short-wave laser
Maximum distance:
•
Multi-mode 62.5 μm cable (OM1)
70 m at 4 Gb/sec; 21 m at 8 Gb/sec; 15 m at 16 Gb/sec
Specification
Hitachi Compute Blade 500 Series System Overview Guide
2-19
Items
Specifications
•
Multi-mode 50 μm cable (OM2)
150 m at 4 Gb/sec; 50 m at 8 Gb/sec; 35 m at 16 Gb/sec
•
Multi-mode 50 μm cable (OM3)
380 m at 4 Gb/sec; 150 m at 8 Gb/sec; 100 m at 16
Gb/sec
•
Multi-mode 50 μm cable (OM4)
400 m at 4 Gb/sec; 190 m at 8 Gb/sec; 125 m at 16
Gb/sec
Scalability
Full fabric architecture with up to 239 switches
Console / management ports
10/100 Ethernet
Serial port (RS-232C)
In-band through the management module
Fabric service
Standard
Fabric service
Optional
Ports On Demand (POD)
(at additional
charge)
Fabric Vision
ISL Trunking
Hardware options
SFP+ (for adding one external port)
Operation management
SNMPv1, SNMPv3, syslog, telnet, http, ftp
Power supply
12 V
External dimensions (W x D x H: mm)
161 x 252 x 32.3
Mass
1.5 kg (including SFP+)
Power Supply Module Specifications
The following table provides the power supply module specifications.
Table 2-29 Power Supply Module specifications
Items
Input
Nominal supply voltage
Specifications
100-127 Vac
200-240 Vac
Permissible supply voltage variation
89-132/178-264 Vac (Continuous)
80-138/160-276 Vac (500 ms)
Frequency
50/60 Hz (±3 Hz)
Current
12 A (Nominal), 13.5 A (500 ms maximum)
Efficiency
84 % at 10 % load
90 % at 20 % load
94 % at 50 % load
91 % at 100 % load
2-20
Specification
Hitachi Compute Blade 500 Series System Overview Guide
Items
Specifications
Power factor
0.95 or greater at 100% load
Inrush current
50 A (100 μs-10 ms after application of AC power)
15 A (10 ms-150 ms after application of AC power)
Leakage current
0.58 mA (264 Vac, 60 Hz)
Output Channels
Main (12 V)
Sub (5 V)
Nominal voltage
+12 V
+5 V
Current
175 A
5A
Power
2142 W (200 Vac)
25 W (200 Vac)
OCP1
200 Vac: 227.5 A (+30 %, 100 ms)
-
OCP2
200Vac: 203A (+16%, 500 ms)
-
OCP
-
5.5 A(10 %, 200 ms)
13.0 V
5.5 V
Protection
Over-current
Over-voltage
Fan Module Specifications
The following table provides the fan module specifications.
Table 2-30 Fan Module specifications
Items
Specifications
Voltage rating
12 V (10.8 to 13.2 V)
Current rating
7.88 A (100 % Duty)
Input power rating
94.6 W (100 % Duty)
Number of fans
2
Maximum air flow
3.45 m3/min (121.8 CFM)
Maximum static pressure
970.0 Pa (3.90 inches H2O)
Operating temperature
5 to 40°C1
Hot Swap
Available
Redundancy
N+1
Mass
1.18 kg
External dimensions (W x D x H: mm)
88 x 83 x 267
Notes:
1.
5 to 30°C [Non-operating: -10 to 43°C] for CB 520H B2 with CPU E5-2637v2 installed. 5 to 35°C
[Non-operating: -10 to 43°C] for CB 520H B3 with CPU E5-2699v3, E5-2697v3, E5-2667v3, and
E5-2637v3 installed.
Specification
Hitachi Compute Blade 500 Series System Overview Guide
2-21
Transceiver and Cable Specifications
The following table provides specifications for transceivers and cables.
Table 2-31 10GBASE-R transceiver specifications
Items
Specifications
Transceiver
XFP-SR
XFP-LR
Interface
10GBASE-SR
10GBASE-LR
Connector
2 league LC connectors
Dimensions (W x
D x H: mm)
18.35 x 78.0 x 8.5
Hot plug
Not supported
Cable type
Multimode
Single mode
fiber-optic cable
fiber-optic cable
50 / 125 μm
Transmission
band
400
MHz/km
500
MHz/km
2000
MHz/km
Transmission
distance
2 m to 66 m 2 m to 82 m 2 m to 300
m
62.5 / 125 μm
50 / 125 μm
160
MHz/km
-
200
MHz/km
2 m to 26 m 2 m to 33 m 2 m to 10 Km
Table 2-32 10GBASE-SR transceiver specifications
Items
Specifications
Form factor
SFP+
SFP
Interface
10GBASE-SR
1000BASE-T
Connector
2 ganged LC connectors
RJ-45
Dimensions
14.8 x 12.4 x 56.7
13.67 x 13.97
x 66.04
Multimode
Cat 5e twisted
cable
(W x D x H: mm)
Cable type
fiber-optic cable
50 / 125 μm
Transmission
band
400
MHz/km
500
MHz/km
2000
MHz /km
Transmission
distance
2 m to 66 m 2 m to 82 m 2 m to 300
m
62.5 / 125 μm
-
160
MHz/km
-
200
MHz/km
2 m to 26 m 2 m to 33 m 100 m
Table 2-33 10 G direct attach cable specifications
Items
Specifications
Form factor
SFP+ (integrated with the cable)
Power consumption
0.25 to 0.27 W
2-22
Specification
Hitachi Compute Blade 500 Series System Overview Guide
Items
Specifications
Cable type
Twinax
Cable length
1m
Regulatory compliance
Complies with IEEE802.3ae
3m
5m
Interface Port Pin-outs
This section describes interface port pin-outs.
USB Connector
The following figure shows USB connector installed in the front panel and
server blades.
Figure 2-1 USB Connector
Table 2-34 USB connector pin-out
Pin
Signal Name
Description
Direction
1
VBUS
+5V supply voltage
Output
2
D-
Data- signal line
Input / Output
3
D+
Data+ signal line
Input / Output
4
GND
Supply Ground
-
RS-232C Interface Connector (Management Module)
The following figure shows RS-232C interface connector installed in
management modules.
Figure 2-2 RS-232C Interface Connector
Specification
Hitachi Compute Blade 500 Series System Overview Guide
2-23
Table 2-35 RS-232C connector pin-out
Pin Signal Name
Description
Direction
1
DCD
Data Carrier Detect. DCE is connected to the telephone line.
Input
2
RD
Received Data. Carries data from DCE to DTE.
Input
3
TD
Transmitted Data. Carries data from DTE to DCE.
Output
4
DTR
Data Terminal Ready. Indicates presence of DTE to DCE.
Output
5
GND
Common Ground
-
6
DSR
Data Set Ready. DCE is ready to receive commands or data.
Input
7
RTS
Request To Send. DTE requests the DCE prepare to receive data.
Output
8
CTS
Clear To Send. Indicates DCE is ready to accept data.
Input
9
RI
Ring Indicator. DEC has detected an incoming ring signal on the
telephone line.
Input
LAN Connector
The following figure shows LAN connector installed in management modules
and switch modules.
Figure 2-3 LAN Connector
Table 2-36 LAN connector pin-out for 100BASE-TX/10BASE-T
Pin
Signal Name
Description
Direction
1
BI_DA+
Bi-directional pair A+
Input / Output
2
BI_DA-
Bi-directional pair A-
Input / Output
3
BI_DB+
Bi-directional pair B+
Input / Output
4
BI_DC+
Bi-directional pair C+
Input / Output
5
BI_DC-
Bi-directional pair C-
Input / Output
6
BI_DB-
Bi-directional pair B-
Input / Output
7
BI_DD+
Bi-directional pair D+
Input / Output
8
BI_DD-
Bi-directional pair D-
Input / Output
2-24
Specification
Hitachi Compute Blade 500 Series System Overview Guide
Table 2-37 Specifications of LAN Interface Connector for 100BASE-TX/10BASE-T
connection
Pin
Signal Name
Description
Direction
1
TX+
Transmit Data +
Output
2
TX-
Transmit Data -
Output
3
RX+
Received Data +
Input
4
N/C
Not connected
-
5
N/C
Not connected
-
6
RX-
Received Data -
Input
7
N/C
Not connected
-
8
N/C
Not connected
-
Specification
Hitachi Compute Blade 500 Series System Overview Guide
2-25
2-26
Specification
Hitachi Compute Blade 500 Series System Overview Guide
A
Service Life Limited Parts
This Appendix-A describes service life limited parts.
□ About service life limited parts for CB 500
Service Life Limited Parts
Hitachi Compute Blade 500 Series System Overview Guide
A-1
About service life limited parts for CB 500
This system unit is designed for life expectancy of five years when operating
for 24 hours a day, 30 days a month. Some parts with limited life expectancy
in the system unit will be degraded or worn out in operation.
The following table shows a main part with limited life. Replacing the part
with limited life is offered at cost. Consult your reseller or maintenance
company.
Product name
SATA hard disk unit
Applicable product model
UH35005X1, UH3N1T5X1
Remarks
1
Notes:
1.
When the system operates with specifications shown in System Unit Specifications
on page 2-2, the estimated service life with power-on is about 26,000 hours. When
the system operates for 24 hours a day, 30 days a month, the estimated service life
is about three years. When you use the system beyond the specifications mentioned
above, an error can occur or the service life can be shortened.
When an error occurs on HDD or SSD, the stable operation of the system is
extremely affected. It is recommended that you replace it with a new one
before the service life expires.
Tip: Product life expectancy is just an estimated limit. It is not guaranteed
that no failure occurs within the period.
A-2
Service Life Limited Parts
Hitachi Compute Blade 500 Series System Overview Guide
B
Expiration of RoHS exemption
This Appendix-B describes expiration of RoHS exemption.
□ About expiration of RoHS exemption
Expiration of RoHS exemption
Hitachi Compute Blade 500 Series System Overview Guide
B-1
About expiration of RoHS exemption
This system unit currently complies with RoHS, containing no hazardous
substance restricted. Some components, however, are exempt from RoHS.
Some RoHS exemptions will be expired in December 2012. Those RoHSexempt components will not comply with RoHS for shipment on or after
January 2013.
Product concerned
RoHS-exempt product
Successor product code
code
to comply with RoHS
not to comply with RoHS
CB500 server chassis
GGX-SRE3A1TBX1
GG-RE3A1NBXR-Y
1 Gb LAN switch module
GGX-BE3LSW1X1
GV-BE2LSW1XR-Y
1/10 Gb LAN switch module
GGX-BE3LSW2X1
GV-BE2LSW2XR-Y
1 Gbps LAN pass through
module
GGX-BE3LPS1X1
GV-BE2LPS1XR-Y
10GBASE-SR XFP module
GGX-CN3XFP1X1
GV-CN2XFP1XR-Y
Note: If any of non-RoHS-compliant products, shown in the center column in
the table above, is installed in a RoHS-compliant chassis, the whole unit does
not comply with RoHS. There is no functional difference between non-RoHScompliant products and their RoHS-compliant successors.
B-2
Expiration of RoHS exemption
Hitachi Compute Blade 500 Series System Overview Guide
Hitachi Compute Blade 500 Series System Overview Guide
Hitachi Data Systems
Corporate Headquarters
2845 Lafayette Street
Santa Clara, California 95050-2639
U.S.A.
www.hds.com
Regional Contact Information
Americas
+1 408 970 1000
info@hds.com
Europe, Middle East, and Africa
+44 (0)1753 618000
info.emea@hds.com
Asia Pacific
+852 3189 7900
hds.marketing.apac@hds.com
MK-91CB500001-12
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project