2033A Series UPS, 30-75kVA Brochure
> 2033AU P S
UNINTERRUPTIBLE
POWER SUPPLIES
Mitsubis
Superior Performance, Reliability and Safety
Come from Experience. Our Uninterruptible
Power Supply Systems Ensure All Three.
Mitsubishi Electric has been developing and manufacturing Uninterruptible Power
Supply (UPS) components and systems for more than three decades. That
experience, and the continuous application of new power-device technologies
to further improve products in the industry clearly explain why Mitsubishi Electric
has dominated a large portion of the world UPS market for years.
When purchasing a UPS system, the key word is “dependability.” And there’s
one company that many rely on. Uninterruptible Power Supply systems by
Mitsubishi Electric.
Intelligent Power Module (IPM)
Transistors with Excellent
Performance Characteristics
Mitsubishi Electric is the leading
manufacturer of Intelligent Power
Modules (IPMs), and now utilizes
Intelligent Power Module transistors in the converters and inverters of its 2033A Series UPS
systems. These advanced, highperformance transistors provide
a variety of intelligent features.
G
G
G
G
G
Drive Circuitry
Overcurrent Protection
Over Temperature Protection
Control Voltage Drop
Protection
Short-Circuit Protection
Low Input Current
Harmonics (THD)
3% typical (100% load)
4% typical (75% load)
G 6% typical (50% load)
(No additional filtering required)
G
G
Generator Sizing Ratio (UPS)
G
1:1 ratio (UPS kVA/
Generator kW)
Low Heat Loss / High
Efficiency
Use of Intelligent Power Module
transistors enables efficient
high-speed switching, thus
reducing heat dissipation in the
UPS. (Higher efficiency means
lower cost per kilowatt
to the customer.)
shi – The Leader in UPS Technology, Quality & Reliabi
ONE-LINE DIAGRAM
2033A SERIES UPS
Maintenance Bypass Circuit
Static Transfer Switch
Bypass Input
Converter
Inverter
Output
Transformer
AC Output
AC Input
Battery
S
O
F
T
W
A
R
What is DiamondLink™?
DiamondLink is user-customizable power monitoring, management and
shutdown software, designed to provide information about the power condition
of the UPS system.
How does DiamondLink work?
DiamondLink is designed to run on network server or workstations in any office
environment. The software will monitor the status of your UPS and, when critical
events occur, will perform a graceful unattended shutdown.
Features
• Automatic unattended shutdown
• Smart messages can be user-defined
• User-defined actions for a specific list of power-events
• Color coded power event logging
• Built-in graphing routines allow customized graphs to be created on-line
• DiamondLink can be used with all Mitsubishi single-phase and
three-phase products
Specifics
• Power history graphs
• Custom user defined events
• Data log viewer
• E-mail configurations
• E-mail options for power events
• Event action
• Events log file
• Modem alert notification
• Pager notification
• Paging option
Supported Operating Systems
• Microsoft Windows ®
• Microsoft Windows NT
• Microsoft Windows ’95
• Microsoft Windows ’98
• Microsoft Windows ’00
• Microsoft Windows XP
• OS/2
• Novel NetWare ®
• SVR4
• SCO UNIX
• SCO XENIX
• Solaris TM
• IBM ® AIX ®-RS/6000TM
• HP-UX
• SGI
• Digital UNIX
• Red Hat (LINUX)
E
ility
OPERATION MENU
ON BATTERY
OPERATION
Extended Battery Life
G
G
Current source from batteries
for step loads is no longer
required with the installation of
Intelligent Power Module transistors in both the converter
and the inverter. Previous UPS
systems required assistance
from batteries when the converter was unable to supply the
required current. This cycling of
batteries caused shorter life.
Mitsubishi Electric Intelligent
Power Modules incorporate
the latest technologies and
provide step load applications
(0-100%) without the use
of batteries, thus ensuring
maximum battery service life
(i.e., lower cost of ownership).
Internal Maintenance
Bypass
All 2033A Series UPS systems
are equipped with an internal
wrap around maintenance
bypass system for greater
maintenance flexibility.
G UL 1778 approved
Superior Control
All 2033A Series UPS systems
use pulse width modulation
(PWM) for superior control and
performance. A digital signal
processor (DSP) ensures
precise control of all input / output
parameters.
Operator-Friendly
Control Panel
Features:
G Mimic bus diagram
G Operator control station
G Touch panel input
LCD Monitor Displays:
G System metering
G Menu-driven start-up
procedures
G Menu-driven operating
procedures
G History of events
G Trend graph
G Load true power factor
Additional Features:
G Password lock out for
start / stop operation
G
EPO button
Real-Time Battery Monitoring
G
G
Remaining battery time
displayed for operator
Integrated “DiamondSense”
system automatically detects
weak cells
Superior Functions
G
G
G
G
G
G
G
Automatic restart
Automatic retransfer
Converter walk-in function
Battery monitoring
Ripple-free DC output (converter)
1 set “Form A” dry contacts of
selectable items
Large overload / overcurrent
capacity
G
G
Battery temperature
compensation
Adjustable DC cut-off
Quiet Operation
G
G
30, 50kVA→60dB (A scale, 1m)
75kVA→65dB (A scale, 1m)
Software
G
G
G
G
G
G
G
RS232C serial interface
DiamondLink application
software
90% of all operating
systems are compatible
with DiamondLink
Multilingual
Paging, E-mail capability
during power events
Auto-dial
Multiple server shutdown
capabilities
Warranty
Standard warranty is two years,
including parts and labor.
(NOTE: All information subject to change
without prior notice.)
GSA Contract Number
GS-07F-9526G
2008 Nemertes Award Winner for
“Best Small Business Provider for Power Systems”
SPECIFICATIONS
UPS Cabinets
kVA
208 V / 208 V Dimensions (W x D x H) (inch)
Weight (lbs)
30
35.4 × 29.5 × 70.9
1,050
50
43.3 × 29.5 × 70.9
1,500
75
43.3 × 29.5 × 70.9
1,700
Notes:
1. All 2033A Series UPS Systems include a “zero energy” maintenance bypass.
2. Batteries not included.
Specifications: 2033A Series 30kVA – 75kVA
Rated Output kVA
30
50
75
Rated Output kW
24
40
60
AC INPUT CHARACTERISTICS
Configuration
3 phase, 3 wire
Voltage
208V, 480V, 600V +10% ~ -15%
Input Power Factor
0.98 typical
Frequency
60 Hz ± 5%
Reflected Current THD
3% max. at 100% load; 5% max. at 50% load
STATIC BYPASS INPUT
Configuration
3 phase, 3 or 4 wire
Voltage
120V / 208V, 277V / 480V, 346V / 600V ±10%
Frequency
60 Hz (±3% tracking window)
BATTERY
Type
VRLA, Flooded Lead Acid, Nickel Cadmium
Ride Through
Application specific
Nominal Voltage
360 VDC
Minimum Voltage
300 VDC
Number of Cells
176 ~ 185
AC OUTPUT
Configuration
3 phase, 3 or 4 wire
Voltage
120V / 208V, 277V / 480V, 346V / 600V
Voltage Stability
±1%
Frequency
60 Hz
Frequency Stability
±0.01% in free running mode
Power Factor
0.8 nominal
Power Factor Range
0.8 ~ 1.0 lagging (within output kW rating)
2% maximum THD at 100% linear load
4% maximum THD at 100% non-linear load
Voltage THD
Transient Response
±3% maximum at 100% load step; ±1% maximum at loss or return of AC power;
±3% maximum at load transfer to / from static bypass
Transient Recovery
Less than 1 line cycle
Voltage Unbalance
2% maximum at 100% unbalanced load
Phase Displacement
1% maximum at 100% unbalanced load
Inverter Overload
125% for 10 minutes; 150% for 10 seconds
System Overload
1000% for 1 cycle (with bypass available)
Bypass Overload
125% for 10 minutes
Withstand Rating
65kA; with optional fuses (only 208V model)
ENVIRONMENTAL
Cooling
Operating Temperature
Forced air
32°F ~ 104° F (0°C ~ 40°C). Recommended 68°F ~ 86°F (20°C ~ 30°C)
Relative Humidity
Altitude
Consult Mitsubishi for Battery Cabinet Configurations.
5% ~ 95% non-condensing
3,300 Feet (1000 meters); 9,000 feet @ 0.99 derating
Mitsubishi Electric Power Products, Inc.
Uninterruptible Power Supplies (UPS) Division
547 Keystone Drive
Warrendale, PA 15086
Phone: 724-772-2555
MK-00003R-REV #1 • February 2009