Manufacturers of Acrylic Baths
Whirlpools & Pedicure Foot Spas
Owners Manual
Thank you for purchasing the La Fleur spa from Gulfstream Plastics Ltd.
Please carefully read instructions before installing La Fleur spa.
By correctly following these instructions; your La Fleur Spa, will give you
years of beauty and service.
Contents:
Section A.
Component Locations
Section B.
Installation Instructions
3
Section C.
Operation and use
4
Section D.
Safety instruction
5
Section E.
Cleaning and Maintenance
Section F.
Specifications
8
Section G.
Appendixes
9
CAUTION:
Must be installed by a, licensed plumber and electrician
in accordance with local codes. Plumbing and
Electrical Installation instructions must be adhered to in
order for the warranty to be in effect and to insure the
utmost in safety. Chair and spa have a maximum
seating capacity of 350 pounds.
1-2
6-7
Section A. La Fleur Component Locations
Shiatsu massage back
Water fill valve
On/Off button for CleanJet motor
Hand held sprayer
Drain control
1
Section A. La Fleur Component Locations
Bottom View
Hot & cold hoses
C.J motor
Back View
Discharge
pump
Outlet for drain
centre to back of unit 6”
ABS piping from
drain to discharge
Discharge pump
(optional)
P Trap
Hot water
connection
Cold water
connection
2
Section B. Installation Instructions
1. Discharge pump installation - The La Fleur
discharge pump may be connected to an existing
sink drain or floor drain. It can also pump up to 20
ft high, but this will increase the length of the drain
time. The drain connection is at the rear of the
unit by a 1/2” fitting.
5. Secure the base - The La Fleur base should
be anchored securely to the floor. The base may
be anchored through the opening in the back of
the base wherever access is convenient for the
installer.
WARNING:
2. Gravity drain installation - The La Fleur uses
a standard gravity drain. A floor drain is the
recommended installation. Connection is via a
1/2”
pipe. A P-Trap is supplied.
3. Water Supply Connections – The La Fleur
hot and cold connections are located at the rear of
the unit. 1/2” Fittings.
4. Electrical installation - Have a qualified
licensed electrician to install the wiring according
to local codes. The CleanJets are 1/5 hp, 120V, 15
AMP 60OHZ. A GFI protected circuit must be used
to supply power to the unit. The roller back
massage chair uses a 115V supply.
3
FAILURE TO ANCHOR THE BASE MAY RESULT
IN PERSONAL INJURY OR DAMAGE TO THE
UNIT. DAMAGE AS A RESULT WILL VOID THE
WARRANTY.
Section C. Operation and Use
1. Fill bowl – Your La Fleur is provided with a
single hot and cold mixing valve located on the
front of your spa(far left). This is a pressure balance
valve that requires you to lift the handle to start the
water flow and to adjust to the temperature that is
desired. The clean jet motor must be completely
submerged in water. CAUTION: DO NOT USE
FOAMING, SUDSING OR MINERAL OIL BASED
ADDITIVES IN THE WATER.
2. To start – Press the button that is situated next
to the water fill lever. This will start your Clean Jet
motor. You may stop the whirlpool function at any
time by pressing the button again.
3. Adjustable air control - The air control
button is situated on the left hand side of the spa
base, just under the chair. You can control the
supply of air to the clean jet motor by turning this
chrome button in a clockwise direction.
depress the thumb control on the sprayer handle.
This will turn on the water. When you release
pressure on the thumb control this will turn the
water off.
5. Adjustable footrest - The La Fleur utilizes a
comfortable 3-position footrest system in which the
footrest can be adjusted by pulling out the pin
located at the centre of the La Fleur base and
placing the pin in one of the tree holes situated on
the footrest stand. You can also slide the footrest
forward by pulling out the pin located at the side
of the actual footrest. This will cause the footrest
pad to slide forward.
With discharge pump
7. 9500 Shiatsu Roller back massage chair Your La Fleur is equipped with a state –of-the-art
massage system. The massage system is easy to
use; the remote has a one touch power that starts
directly in the auto function mode, or you can
select your own massage. This is illustrated on Pg
You can also adjust the front to rear position of the
chair and the reclining back. By using the remote
your client can adjust the back to the most
comfortable position.
6. To drain whirlpool tub – La Fleur. The La
Fleur is equipped with a built in discharge pump.
Open the drain plug by turning the control knob
which is situated at the far right of the spa base.
The discharge pump will turn on automatically and
the water will drain.
4. Hand Shower – The La Fleur is equipped with
a hand held sprayer. To activate the hand shower,
pull the hand shower from the receptacle and
4
Section D. Safety Instructions
CAUTION: BASIC PRECAUTIONS SHOULD ALWAYS BE OBSERVED, INCLUDING THE FOLLOWING
1. Read and follow all instructions
2. DANGER. To reduce the risk of injury, do
not permit children to use this unit unless
they are supervised at all times.
3. Use this unit only for its intended use as
described in this manual. Do not use
attachments that are not recommended by
the manufacturer.
4. Never drop or insert any object into any
opening.
5. Do not block jets during whirlpool operation.
6. The unit must be connected to an
electrical supply circuit that is protected by
a ground fault circuit interrupter.
7. SAVE THESE INSTRUCTIONS.
5
Section E. Cleaning & Maintenance
Gulfstream Plastics Ltd highly recommends the
following cleaning regimen. You should always
contact your local governing agency for their
specific cleaning and disinfecting requirements and
regulations for pedicure spas. For your clients
safety, always use the regulations as a minimum
standard for cleaning and disinfecting. Combining
your states standards with the regimen listed below
will provide your clients with a safe and healthy
pedicure spa environment experience.
1. Routine maintenance. Powdered cleansers or
abrasives are NOT RECOMMENDED. A clean towel
or sponge, are all that are usually needed. A soft
bristled brush may be used when excessive residue
is present. Use a mild soap and water solution to
clean the upholstery, but do not over wet. Wipe
dry with a clean towel. No internal maintenance of
the spa components is necessary. Remove clean jet
caps and spray with disinfectant after each use.
For extra protection, our recommendation is that
the system be flushed daily or weekly depending
on use. To flush the clean jet system fill spa with
hot water to just above the jets. Add disinfectant.
With discharge pump
Run whirlpool for 15 minutes, drain and then wipe
dry with clean soft cloth.
NOTE: Cleaning or sanitizing is NOT
disinfecting. According to the Centers for
Disease Control and Prevention (CDC), and
the US Environmental Protection Agency
(EPA), disinfecting occurs only when there is
a reduction of pathogenic microbes at
99.999%. Sanitizing is only a reduction of
99.9%. Cleaning of whirlpool pedicure spas
requires surfactants and chelating
detergents that are low-foaming and have
the ability to remove body oils, organic oil
additives, mineral oil, skin cells, nail
clippings etc that can accumulate both in
the basin and the jets which may become
a fertile area for micro organisms to grow.
The use of oil based products can build up in the
whirlpool system causing clogging in the jets.
Adherence to the above cleaning will minimize
build up. Gulfstream Plastics Ltd does not
recommend the use of mineral oil based products.
6
Section E. Cleaning & Maintenance
Remove screen by turning counter-clockwise.
Clean intake area using a soft bristled brush or cloth and low foam soap to remove any
visible residue. Rinse with sprayhead - Cold water
Clean back of screen Jet with same soft brush or cloth. Rinse with cold water
7
Replace screen by turning clockwise
Section F. Specifications
With discharge pump
43"
Discharge 1/2 IPS
Hot 1/2 IPS
Cold 1/2" 1/2 IPS
15"
32"
Extension
1-1/4" Drain
1-1/4"
P- Trap
19"
55"
27"
8