Key Features
• Smart touch keypad with 4 line message LCD display
• Quad-band GSM communication, works with SIM card
• Calender, five personal emergency phone numbers
• One central monitoring station phone number
• Alarm notification via phone call or SMS
• Built-in speaker and microphone
• Remote two-way intercom
• Extra SMS phone number for system's status
• Alarm memo, entry delay, exit delay
• Hybrid alarm, 30 wireless zones, 4 hardwired zones
• Advanced zone attribute, user-friendly zone names
• Temperature display and relay signal output
• Support wireless LCD/LED keypad and wireless siren
• Support user code and installer code
• 100 alarm log
• SMS alert, when system: Arm/Disarmed, sensor's low battery, AC power
failure, phone line disconnect
• Reset factory design
• Built-in siren
• Alarm communication via ADEMCO Contact ID protocol
• Backup rechargeable battery, last more than 24 hours
• Work with CCTV system, IP camera
3
Technical Information
• Power supply: AC=100 ~ 230V 50Hz/60Hz
• Working voltage: DC12V 1A
• Static current: < 35mA (when not in charging)
• Alarm current: < 120mA
• Backup Battery: 3.7V 800mA
• Standby time: Around 24 hours
• Charging time: 8 hours
• GSM frequency: 850/900/1800/1900MHz
• GSM Transmission power: 2W
• Receiving and emitting frequency: 433MHz (868MHz optional)
• Wireless transmission distance: ≤100 m (Open space)
• Working condition:Temperature: -10ºC ~ 50ºC Humidity:5% ~ 80%
4
Font panel View
q
w
a
s
d
f
e
r
t
q
r
u
a
f
LCD Display
Burglary
Home/Stay Arm
Up/Away Arm
Confirm/Save
y
w
t
i
s
uio
GSM Signal LED
Medical Help
Down/Disarm
Left/Delete/Log/*
e
y
o
d
Fire Alarm
SpeedDial Button
SET/Exit
Right/Phone Call/#
5
Back panel View
Anti-Tamper Switch
Speaker
Installation Bracket
Wired Connection
Reset
| +12V- |31 32 33 34 |-BELL+|No Com|
ON OFF
DC 12V input jack
Telephone line
6
SIM Card Slot
Arm/Disarm System
Disarm
In keypad, touch
then, input xxxx+OK
Remotely via SMS, send SMS content: xxxx0
Remotely via phone, make phone call to alarm
system, after pick up, input xxxx#, you will hear "di"
sound, press 3 to disarm.
Notice
"xxxx" is the current user code, default user code
is "1111", and default admin/installer code is "1234"
Activate Away Arm
In keypad, touch
to activate Away Arm.
Remotely via SMS, send SMS content: xxxx1
Remotely via phone, make phone call to alarm
system, after pick up, input xxxx#, you will hear "di"
sound, press 1 to activate the Away Arm.
The system is working with separate wireless LCD/
LCD keypads, for activate and deactive operation,
please refer to manual of wireless keypad.
Activate Stay Arm
In keypad, touch
to activate the Stay Arm
Remotely via phone, make phone call to alarm
system, after pick up, input xxxx#, you will hear "di"
sound, press 2 to active the Stay Arm
7
Voice Memo/Phone Call
Quick Alarm
Touch
Touch
Touch
for 2 seconds to trigger fire alarm.
for 2 seconds to trigger burglary alarm.
for 2 seconds to trigger medical help.
Recording Voice Memo
When system is in Disarm status, touch OK
for 2 seconds for recording memo.
Maxim recording time is 10 seconds.
Playback Voice Memo
When system is in Disarm status, touch OK
the system will playback the voice memo.
Check System Log
The system can record 100 pieces event log, you
can touch
X to check these log, when system
is not in setup status.
8
Make Phone Call
When alarm system in disarm status, you can
make phone call via alarm panel. Touch
then
input the phone number, touch
to make
OK
phone call.
The function enables alarm system can be used as
a portable cell phone.
Pick up Phone Call
If there is a phone call to alarm system, the confirm
circle's LED will light up, and you can touch
OK
to pickup phone call.
Speed Dial Function
When touch " A" or "B" key on the keypad, the
alarm system will make the speed dial phone call
with preset phone numbers (eg: the person that
needs to be notified in case of an emergency, a
carer, Mum or Dad).
Basic Alarm Setting
Enter into Setting Status
When system is in Disarm status, touch
then input admin code, default "1234", touch "OK"
for confirm, to enter into setting status.
System Time setting
When system is setting status, choose the "Time
Setting" for modifing the current time. The time
will automatically back to default, once the alarm
system is complete OFF.
Time Setting
Phone No. Setting
SMS Setting
Record
>
Time Setting
04:54:08
09/11/2013
THU
>
Touch " ▲▼ " to select and " X " to delete the
default date, then enter with new time (XX hours,
XX minute, XX second). Do same procedure for
date.
Touch " ▼ " and " ◄► " select the week, touch
"OK" to confirm all settings.
Alarm Receiving Phone Number
This alarm system can totally preset up to 5
personal emergency phone numbers for alarm
receiving.
Time Setting
Phone No. Setting
SMS Setting
Record
>
Phone Groups
1
Alarm Call
28901540
>
Touch "◄► " to select the Alarm Call or Alarm
SMS, then touch "▼ " , you can input the number.
1st and 2nd group for setting Alarm SMS, 3rd
group for setting Alarm SMS or Alarm Call, 4th&5th
groups for setting Alarm Call.
Touch "
X " you can delete the existing phone
number.
You need touch "OK" to save, and navigate into
next phone number setting menu.
Notice: Maximum digitals for phone number input
is 15.
9
Basic Alarm Setting
SMS Number for System Status
The alarm system can preset one phone number
for receiving SMS report of system's status,
including AC power recover, Arm/Disarm, PSTN
OFF, Host Low Voltage, Sensor Low Voltage.
Time Setting
Phone No. Setting
SMS Setting
Record
>
SMS Phone No.
AC Power Recover
Arm/Disarm SMS
1388888888888
OFF
OFF
PSTN Off
Host Low Volt
Sensor Low Volt
OFF
>
OFF
>
OFF
>
>
>
Touch " X " to delete exist phone number, enter new mobile phone number. Touch " OK" to save the
phone number, it will navigate to event report selection.
Touch "◄►" to select enabled or disable the event report.
AC power recover means when external electricity is recover, the alarm system will send SMS.
Arm/Disarm SMS means when alarm system is Armed or Disarmed, the system will send SMS.
PSTN Off means when fixed phone line is cut or with trouble, the system will send SMS.
Host Low Volt means when backup battery is low, the system will send SMS.
Sensor Low Volt means when battteries run out in wireless sensors, it will send SMS.
10
Advanced Alarm Setting
Record Voice Memo
The system allows user to record up to 10 seconds
voice memo. When alarm phone call is picked up,
press "5" to listen the voice memo.
Record
OFF
Record
>
Recording Time
10
Touch "◄►" to choose "On" to record voice, and
touch "OK" to start voice recording.
Arm Delay/Exit Delay
The Arm delay or exit delay can allow user to exit
protected area before system is Armed. The time is
adjustabe from 00 to 59 seconds.
Arm Delay
Alarm Delay
Siren Setting
Tone Setting
Alarm Delay/Entry Delay
The alarm delay or entry delay can allow user to
set alarm delay zones before system set alarm off.
This allow user enter into specific detection area to
disarm the system without triggering alarm.
Arm Delay
Alarm Delay
Siren Setting
Tone Setting
Alarm Delay
>
Seconds
10
X " to delete exist data, and input new
Touch "
seconds e.g 10. It accpet time between 00 - 59.
Touch "OK" to save.
Notice: You need go to [Zone attribute] to enable
which zones are belong to this function, therefore it
can work.
Arm Delay
>
Seconds
10
Touch " X " to delete default data, and enter new
time. Touch "OK" to save.
11
Advanced Alarm Setting
Siren Setting
It allows siren time setting for each of zones. The siren
time can be set from 00-59 minutes. User can choose
whether use built-in siren or not. The function is useful, if
user want to choose mute alarm.
Arm Delay
Alarm Delay
Siren Setting
Tone Setting
Zone No.
Siren Time
00
>
Minute
Built-in Siren
01
On
>
Touch " X " to delete the zone number, and input new zone number from 00-34. Touch "OK" to save
Touch " X " to delete the siren time, and input new siren time, "00" means disable. Default value is 01
Touch "◄►" to choose "On" to enable built-in siren, and touch "OK" to save.
Tone Setting
Temp Alert
Tone setting means the alarm system will make
"beep" sound, when detects system event, such as
telephone line cut, Arm/Disarm, Temperature Alert.
Arm Delay
Alarm Delay
Siren Setting
Tone Setting
12
PSTN OFF Tone
>
Off
Off
▲
Arm/Disarm Beep
Arm/Disarm Tone
>
Off
>
>
Off
>
Call in Setting
Call in Setting
The system can receive the phone call via telephone line and GSM. It allow user to set the ring times
from 1 to 9. When the ring time reach to preset times, it will pick up the phone call for remotely control.
Call in Setting
Program&Delete
Zone Attribute
Upload
>
Touch "
PSTN Call in Tone
GSM Call in Tone
9
3
X " to delete exist data, It accpets ring time between1-9. Touch "OK" to save.
Program&Delete
Use this function to program/delete wireless sensors and accessories (remote keyfob, wireless LED/LCD
keypad). The wireless zone number is from 00-30. Zone 00 is for programming wireless remote keyfob or
keypads.
Call in Setting
Program&Delete
Zone Attribute
Upload
>
Zone No.
Program
Delete
00
Zone No.
Programming
00
Zone No.
Success
Delete
00
13
Zone Programming
Touch " X " to delete the zone number, and input new zone number from 00-30. Touch "▲▼" to choose
[program], then touch "OK", the LCD will display [Programming]. Trigger the wireless sensors/accessories
for two times, the LCD display [Success], touch "OK" to save, you can continue to enroll more sensors.
Touch " X " to delete the zone number, and input new zone number from 00-30. Touch "▲▼" to choose
delete, the LCD will display [Success], touch "OK" to save. This will erase the current sensors in the zone
from the alarm system.
Zone Attribute
The system has advanced zone attribute, it allow user to choose each of attribute for the zones, it helps
user to customize the system, which can be more suitable for specific installation. Ensuring the zones with
correct attribute, therefore sensors can work properly.
Call in Setting
Program&Delete
Zone Attribute
Upload
>
Zone No.
01
Activate
0 Defence Line
00Help
Alarm Delay Off
>
>
>
>
Zone Chime Off >
Smart Sensor Off >
Touch " X " to delete the zone number, and input new zone number from 00-30. Touch "OK" navigate to
next menu. Touch "OK" you will navigate to last level menu.
Bypass Sensor: Touch ""◄►" to choose "Disable" to deactivate/bypass this zone.
Zone type: Touch "▲▼" to choose defense line, touch "◄►" to change the value from including 0, 1, 2.
Sensor type: Touch "▲▼" to choose sensor type, touch "◄►" to change the sensor type.
Alarm Delay: Touch "▲▼" to choose alarm delay off, touch "◄►" to enable or disable the alarm delay.
Zone Chime: Touch "▲▼" to choose zone chime off, touch "◄►" to enable or disable this function.
14
Zone Attribute
Smart Sensor Off: Touch "▲▼" to choose smart sensor off, touch "◄►" to enable or disable this
function.
Notice:
[0 Defense line] means fire, panic alarms, which are belong to 24 hours emergency zone. It will trigger the
alarm system, even the system in disarm status.
[1 Defense line] means perimeter protection, which is belong to perimeter zone. It will work when alarm
system in both Away Arm and Home Arm modes.
[2 Defense line] means interior protection, which is belong to motion zone. The sensors in this zone will
be activated when system is in Away Arm mode, but will be de-activated, when system in Home Arm/Stay
Arm mode.
Default Zone Type
Zone Number
00
01 ~ 10
11 ~ 20
21 ~ 30
31 ~ 34
Zone Type
N/A
Emergency Zone
Perimeter Zone
Motion Zone
Hardwired Zone
Sensor Type
Sensors
Wireless Remote Keyfob Maximum 10 pcs
Wireless Sensors
Panic, Smoke, Gas Leak
Door sensor, IR beam
PIR motion sensor
Hardwired Sensors
Default zone number for sensor and keyfob for standard alarm kit
Wireless Remote
Wireless Door Sensor
Wireless PIR motion
00
12
21
Wireless Smoke
02
15
Monitored Alarm Setting
Upload
The system can either be used as self-monitoring system or monitored by security company. It's
compatible with ADEMCO Contact ID protocol for alarm monitoring. If you want to link the alarm system
into alarm monitoring centre, you need to do this operation. More over, the system can not only upload
alarm information, also can upload system's status to central monitoring station.
Call in Setting
Program&Delete
Zone Attribute
Upload
>
Center Phone No.
User Code
911
Upload Status?
0001
Off
>
Touch " X " to delete exist number, and input new alarm monitoring centre number. Touch "OK" to save,
then navigate to next level menu, touch " X " to delete default user code, and input your user code,
touch "OK" to save, then navigate to next level menu, touch "▲▼" to choose disable or enalbe upload
status, touch "OK" to save, navigate to next status selection menu.
Period Test
00000
AC Fail Upload
Off
16
Host Low Volt
>
Off
▲
Sensor Low Volt
>
Off
Manual Test
>
Off
>
User/Admin Code Setting
User Code
Navigate to this menu, user can modify the user
code. The user code with authorization for Arm/
Disarm the system via keypad, SMS, phone call,
mobile applications (APP). The default user code
is "1111".
Password Setting
Pin Setting
Reset
Time Arm/Disarm >
Password Setting
####
Reset
Navigate to this menu, user can reset the alarm
system. The system will reset to factory status.
If user have done wrong programming, can not
be solved, then you can use reset function. It will
erase all the user's programming data.
Password Setting
Pin Setting
Reset
Auto Arm/Disarm >
Reset
Off
>
Touch "◄►" to choose "On" , then touch "OK" to
reset the alarm system.
Admin Code
Navigate to this menu, user can modify the admin
code. The admin code with authorization for
programming the system. The default admin code
is "1234".
Password Setting
Pin Setting
Reset
Time Arm/Disarm >
Pin Setting
####
17
Auto Arm/Disarm
Auto Arm/Disarm
This function can make the alarm system automatically Arm/Disarm in preset time for
everyday.
Password Setting
Pin Setting
Reset
Auto Arm/Disarm >
SUN
--:-- Away Arm
--:-- Stay Arm
--:-Disarm
MON
--:-- Away Arm
--:-- Stay Arm
--:-Disarm
Touch " X " to delete the default time, and input new time e.g: 1200, touch "▲▼" navigate to next time
setting, touch "OK" to save, it will navigate next day for auto arm/disarm setting.
Notice:
The time format should be 12:00, hours then minutes. Wrong time input can not be saved.
Temperature Control
This system is built-in temperature sensor for monitoring onsite temperature. You can set the upper limit
and lower limit to make temperature alert (NC. dry contract output).The temperature range can be from
00° ~ 70° . If you enabled SMS notification, then it will send the text message alert. If choose output OFF,
then the dry contract will be used as alarm output.
Temp Control
Speed Dial
Temp Upper limit
Output On
18
32
Temp Lower limit
>
Output Off
15
>
Speed Dial Phone Call
Speed Dial
There are two special buttons on the keypad, they are "A, B". User can preset phone number for this two
buttons. When system is in Disarm status, the user can touch "A" or "B" for making speed dial phone call.
The phone number can be the person that needs to be notified in case of an emergency, a carer, Mum or
Dad.
Temp Control
Speed Dial
A Phone No.
1008610086
B Phone No.
>
10011001
>
Notice:
After finish the setting, you can touch
to exit setting status. The system will automactially exit setting
status, when without any operation on keypad.
19
Alarm Handle for User
Receiving Alarm SMS
Once an alarm occurs, the system will send SMS as long as user choose for alarm SMS notification. The
system will send SMS with below content:
(0001)Alarm System: 11 Zone Door Sensor Alarming
Inquiry System's Status
The system allow user to inquiry the system's status, send "User code + C" text message to alarm
system, alarm will reply text message inform you whether it's Armed or Disarmed.
SMS Content:XXXXC
20
Alarm Handle for User
Receiving Alarm Phone Call
Once an alarm occurs, the system will make phone call as long as user choose for alarm call notification.
The alarm systems support remotely control via phone call, including Away Arm/Stay Arm/Disarm, Onsite
voice monitoring, listen voice message, talk back, two-way intercom, recording meno.
When pickup alarm phone call, you will hear the siren sound, after the replay, you can:
• Press "1" on the phone to Away Arm (It will hang up immediately, system will be Away Armed)
• Press "2" on the phone to Stay Arm (It will hang up immediately, system will be Stay Armed)
• Press "3" on the phone to Disarm (It will hang up immediately, system will be Disarmed)
• Press "4" on the phone to listen onsite voice (It will hang up, after 20 seconds delay)
• Press "5" on the phone to listen voice memo
• Press "6" on the phone to talk back (fixed phone number doesn't support this function)
• Press "7" on the phone to record voice memo (Maximum 10 seconds, except fixed phone number)
• Press "8" on the phone to begin two-way intercom (except fixed phone number)
• Press"*" on the phone for alarm confirmation, it will hang up, stop to dial phone call
21
How to Use Wireless Keyfob
Working LED
Disarm
Stay Arm
Arm/Disarm/SOS
Away Arm the system by press:
Stay Arm the system by press:
Disarm the system by press:
Trigger SOS alarm by press:
22
Program&Delete
Away Arm
SOS
Go to [Program&Delete] for programming wireless
remote keyfob, program keyfobs in sequence into
zone 00
Call in Setting
Program&Delete
Zone Attribute
Upload
>
Zone No.
Program
Delete
00
To u c h " ◄ ► " t o c h o o s e " P r o g r a m " , t h e n
touch "OK" to confirm, the LCD will display
[Programming]
Now press the " " button for two times, the LCD
will display [Success], then touch "OK" to save.
Zone No.
Program
Delete
00
Zone No.
Success
Delete
00
Touch "◄►" to choose "Delete" , then touch "OK"
to confirm, the LCD will display [Success], then
touch "OK" to save.
How to Use Wireless Door Sensor
Introduction
Wireless door sensors or entry point sensors are the most reliable intrusion detection device for perimeter
protection. The door sensor is adopting reed switch theory, it consists of wireless transmitter and magnetic
two parts. When two parts sperate maximum 1cm, the sensor will send alarm signal to alarm system.
LED Indicator
Program&Delete
Go to [Program&Delete] for programming wireless
remote keyfob, program keyfob in sequence into
zone 11~20
To u c h " ◄ ► " t o c h o o s e " P r o g r a m " , t h e n
touch "OK" to confirm, the LCD will display
[Programming]
Now separate door sensor for two times, the LCD
will display [Success], then touch "OK" to save.
Tamper Swtich
Zone No.
RF transmitter
Panic button Magnetic
Battery
Notice:
The door sensor in the package may differ from
manual.
Program
Delete
11
Zone No.
Success
Delete
11
Touch "◄►" to choose "Delete" , then touch "OK"
to confirm, the LCD will display [Success], then
touch "OK" to save.
23
How to Use Wireless Door Sensor
Installation
• Remove the insulating protect on battery.
• Mount the transmitter on the door frame and the magnet on the door
• Make sure that the magnet is always on the right side of the transmitter.
• Make sure that the magnet will not be more than 1 cm from the transmitter.
• Attach the transmitter and the magnet with double-sided tape or the screw.
• Avoid placing the detector in areas with large-metallic structures or electrical installations such as boiler
area or counters
Technical Information
• Working voltage: 1.5V LR6
• Static current: ≤30 μA
• Alarm current: ≤40mA
• Emitting frequency: 433MHz /(868MHz optional)
• Transmission distance:≤100 m (Open space)
• Lifespan of battery: ≤ 12 months
Notice:
The door sensor in the package may differ from manual. The specification will change, when use different
model of wireless door sensors.
24
How to Use Wireless PIR Sensor
Introduction
PIR motion sensor is one of common intrusion sensor for instruction detection. It with advantages of large
space protection, lowest energy consumption. It detects infrared energy changes which is caused by
movement of human.
Program&Delete
w
q
e
1. Wide angle fresnel lens Go to [Program&Delete] for programming wireless
remote keyfob, program keyfob in sequence into
2. Alarm LED Indicator
zone 21~30
3. Swivel Bracket
To u c h " ◄ ► " t o c h o o s e " P r o g r a m " , t h e n
touch "OK" to confirm, the LCD will display
[Programming]
Now triggering PIR sensor for two times, the LCD
will display [Success], then touch "OK" to save.
Zone No.
Program
Delete
21
Zone No.
Success
Delete
21
Touch "◄►" to choose "Delete" , then touch "OK"
to confirm, the LCD will display [Success], then
touch "OK" to save.
25
How to Use Wireless PIR Sensor
Installation
Due to the wide coverage angle and the swivel bracket, the motion sensor can easily be installed:
• Indoor environment only!
• Wall mounted on the wall and sensor points to entry point of doors
• Wall mounted on corridor to detect movement
Technical Information
• Working voltage: 2x1.5V LR6
• Static current: ≤50 μA
• Alarm current: ≤9.5mA
• Detection angle: ≤ 110°
• Detection distance: ≤ 12 m
• Emitting frequency: 433MHz /(868MHz optional)
• Transmission distance:≤100 m (Open space)
• Lifespan of battery: ≤ 12 months
Notice:
The PIR sensor in the package may differ from manual. The specification will change, when use different
model of wireless PIR sensor.
26
Appendix
Zone Name & CID Code
Item
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
Zone Name
Help/Medical Alarm
Emergency
Emergency
Fire Alarm
Smoke Alarm
Kitchen
Gas Leak Alarm
Tamper Alarm
Heat Alarm
Perimeter Zone
Door
Front Door
Back Door
Side Door
Window
Glass Break
Vibration
Motion Zone
Garage
Motion
CID Code
E100
E121
E120
E110
E111
E130
E112
E137
E158
E131
E134
E134
E134
E134
E131
E131
E130
E132
E130
E132
CID Name
Medical
Duress
Panic
Fire
Smoke
Burglary
Combustion
Tamper
High temp
Perimeter
Entry/Exit
Entry/Exit
Entry/Exit
Entry/Exit
Perimeter
Perimeter
Burglary
Interior
Burglary
Interior
27
Appendix
Item
20
21
22
23
24
Zone Name
Lobby/Family room
Bedroom
Book room
Other
(Door Bell)
CID Code
E130
E130
E130
E140
N/A
CID Name
Burglary
Burglary
Burglary
General Alarm
N/A
Hardwired Zone Connection
Notice:
Hardwired zone number from 31~34. All hardwired zones are disabled/de-activated. If you want to use
the hardwired zones, you need go to [Zone attribute] to enable them.
EOL resistor must be connected to hardwired sensor for zone protection, it can make hardwired sensors
work properly.
"A1" means wired zone, "V1" means DC power (either from alarm panel or separate power supply)
28
Maintenance and Care
This alarm system is a Hi-Tech product with outstanding design and sophisticated technology, and shall
be carefully.
• To make the alarm to operate for a long term stably and to prolong the service life, it's recommended
that:
• Try to put the alarm panel in a dry and well-ventilated location
• Do not put the alarm panel and any wireless sensors in too cold, too hot or dusty places to prevent it •
from curtailing the service lives of electric parts and preventing the plastic shell from distorting.
• Do not put the alarm panel and any wireless sensors in low and too exposed places to prevent children
from touching them or the thieves from finding them
• Reglar testing is necessary for finding and resolving probles in time.
• Regulary check the batteries in all wireless sensors. To ensure normal operations of the system,
replace with new batteries whenever you feel a sensor is not detecting properly.
29
System Note:
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising