LightSweep system setup

LightSweep system setup
GE Lighting Control
LIGHTSWEEP SYSTEM SETUP
GE Lighting Control
LightSweep CLCDLS
Contents
Navigation ..................................................................................................................................................... 2
Button Icons .............................................................................................................................................. 3
Home page (GE logo) ............................................................................................................................ 3
Exit (X) ................................................................................................................................................... 3
Setup (Gear) .......................................................................................................................................... 3
Look-up (Magnifying Glass)................................................................................................................... 4
Swiping pages........................................................................................................................................ 4
Status Icons ........................................................................................................................................... 4
Basic Procedures ........................................................................................................................................... 5
System Setup ............................................................................................................................................ 6
CAN ID ....................................................................................................................................................... 7
Location Setup .......................................................................................................................................... 7
Network View ........................................................................................................................................... 9
Device Programming ...................................................................................... Error! Bookmark not defined.
GS ........................................................................................................................................................ 12
RM ....................................................................................................................................................... 14
Programming Schedules ............................................................................................................................. 15
Date/Time ............................................................................................................................................... 15
Schedule configuration ........................................................................................................................... 16
Selecting a Schedule ........................................................................................................................... 16
Daily Schedule setup ........................................................................................................................... 16
Special days ......................................................................................................................................... 19
Assign targets ...................................................................................................................................... 22
Assign targets ...................................................................................................................................... 23
Astronomical – .................................................................................................................................... 24
Sweep .................................................................................................................................................. 25
Page 1
GE Lighting Control
LightSweep CLCDLS
LightSweep Lighting Control system
Communication protocols:
LightSweep system is using two communication protocols:
-
-
CAN bus – communication between field devices:
o
CLCDLS – touchscreen/scheduler
o
CLCGSM8 – group switch input module – eight inputs
o
CLCRM6/CLCRMS6 – relay modules – six relays
o
CLCDIM4 – 0-10V dimming module – four dimming channels
o
CLCSWTx – dataline switch stations – 12,4,8 buttons per station
o
CLCBnet – BACnet controller – to the CAN bus port
BACnet – using CLCBnet controller – offers communication to other sub-systems or computer
front-end, integration to BMS
o
BACnet Ethernet
o
BACnet MSTP
o
BACnet RS232
o
BACnet UDP/IP
System setup:
In order to integrate the LightSweep lighting control system with the BMS, need to follow the process
outlined below using the CLCDLS touchscreen programmer:
-
Assign a unique address (range 0-99) to each device on the CAN bus.
-
Verify the network integrity and device addresses via CLCDLS touchscreen (see Network View)
-
Define the relay panels – see Relay Panel Setup
-
Configure the input types:
o
Switch (default)
o
Occupancy sensor
o
Photocell
-
Program the groups – dataline switches and group switch intputs
-
Configure the dimming channels – setpoints, response rate.
Communication setup
Using the GELC software, setup the communication parameters on CLCBnet device. If there are multiple
CLCBnet controllers in the system, configure each unit with a unique address. The CLCBnet default
address is 100.
Page 2
GE Lighting Control
LightSweep CLCDLS
CLCDLS – programming instructions
Navigation
Button Icons
Button Icons
Home page (GE logo)
The home page can be accessed at any time by touching the GE logo. The logo is located in the top-left
of each page. This will bring you back to the main page as seen in figure 1.0
Figure 1.0
Exit (X)
The X symbol, located in the top right of each page, exits the current page and return to you previous
screen you were at.
Setup (Gear)
The gear symbol displays the setup page as seen below.
Page 3
GE Lighting Control
LightSweep CLCDLS
Look-up (Magnifying Glass)
Touch the magnifying glass to access the look-up reference at relay level or schedule level. When doing
look up at relay level it will display associated LC’s the relays are assigned too, and at schedule level it
will indicate LC’s assigned to schedule.
Swiping pages
If multiple pages are available, swipe a finger from right to left, across the page, to advance to the next
page. Swipe from left to right to return back to the previous page.
Multiple pages are indicated by a sequence of circles in the center of the screen. The number of circles
indicates the number of pages available, and the filled circle indicates which page is currently displayed.
Status Icons
Schedules have color coding to provide additional information.
Page 4
GE Lighting Control
LightSweep CLCDLS
Schedule Color:
•
Red – Schedule is On
•
Light Gray – Schedule is Off
•
Dark Gray – Schedule has no current entries.
Status Color:
•
Red – All lighting targets match active state
•
Green – Some lighting targets match active state
•
White – All lighting targets match inactive state.
•
Yellow – Status of targets is unknown
•
Grey – No targets defined
•
Blue – Circular reference detected (Nested LC references have created a loop that will
need to be fixed)
Basic Procedures
Page 5
GE Lighting Control
LightSweep CLCDLS
System Setup
System setup is done from the Setup screen, which is easily accessed from the system home page.
To modify the System Setup:
1.
From the main screen, touch Setup.
2.
The Setup page is displayed.
The following options are available:
•
CAN ID – Displays network address of current scheduler (CLCDLS)
•
Location – Setup your current location to calculate sunrise/sunset times for astronomical clock.
•
Calibration – Local LC groups on network clock (CLCDLS)
•
Chg Pwd – Setup main numerical password before allowing user to access any buttons on
CLCDLS.
•
Clear DB – Erase all programming on CLCDLS.
•
Network – Status of network devices if they are online or offline.
Page 6
GE Lighting Control
•
LightSweep CLCDLS
Devices – Configuration screen for group module (CLCGSM8), relay module (CLCRSM6), dimming
module (CLCDIM) and network switches (CLCSWTx)
•
Panel ID – Setup relay modules to be displayed as single lighting control panel (LCP).
CAN ID
To setup or change the default address (99) of the network clock CLCDLS.
1.
2.
Touch the CAN ID from the setup menu.
Use raise and lower buttons to change the address number and select Save.
Location Setup
Time adjustments for daylight savings are handled automatically by configuring the system location
coordinates. This can be done manually or automatically.
To manually set the Location Coordinates:
1.
From the Location page, adjust the Longitude and Latitude for the current location.
Page 7
GE Lighting Control
2.
LightSweep CLCDLS
Use the checkboxes for DST (daylight savings time) or UTC (Coordinated Universal Time)
if needed.
3.
Touch Save to set the location.
If the exact longitude and latitude are not known, select a city from the included list that is nearest the
current location.
To automatically set the Location Coordinates:
4.
From the Regions page, select a Region.
5.
Select a specific City from the Region. Swipe left or right to view the complete list of
available cities.
Page 8
GE Lighting Control
6.
LightSweep CLCDLS
If the specific location is not available, select a nearby city. Since the location is used
primarily for Time Zone purposes, an approximate location is usually sufficient.
Network View
Network configuration is accessed from Setup menu. The network page displays a list of all devices
connected to the system.
To access the Network View:
7.
Touch Network from the Setup menu.
8.
The Network page appears. It will display the network address of the devices and if device
is offline it will highlight them in red. Below are the devices that may reside on your
network.
a.
DMx – Dimming module (CLCDIM)
b.
GSx – Group switch module (CLCGSM8)
c.
SWx – Network switch (CLCSWTx)
d.
RMx – Relay module (CLCRMS6)
Page 9
GE Lighting Control
e.
DLSx – Network scheduler (CLCDLS)
f.
Bnet – BACnet module (CLCBNET).
LightSweep CLCDLS
3. The cleanup button allows you to remove any offline device from the network screen if it
has been disconnected from the network.
Relay Panel Setup
Create Relay panel configuration
From the Setup Screen select Panel ID
Page 10
GE Lighting Control
LightSweep CLCDLS
Highlight the relay module position in the panel 1 through 8)
Click the Add button and select the relay module CAN address in that position ->Add.
Follow the steps for all relay modules in the panel then repeat for all relay panels in the system.
System Programming
Devices are programmed from the Device List.
To view Devices:
Page 11
GE Lighting Control
LightSweep CLCDLS
1.
Touch Devices from the Setup menu.
2.
The Device List appears. To program the group switch module (CLCGSM) select the GS
module and select details button. It will display the eight inputs that can program to
control any number of relays in the network
GS
3.
To program LC3 highlight the group and select edit from the menu.
Page 12
GE Lighting Control
LightSweep CLCDLS
1.
Highlight the relay module you want to add or LCP panel if Panel ID was used.
2.
Highlight relays to add to group, and either if you want to function as ON/OFF, ON only,
or OFF only.
Page 13
GE Lighting Control
LightSweep CLCDLS
RM
1.
To configure flick warn time for individual relays select the relay module and highlight
relay. Select the edit button which will give the relay details to making adjustments.
Flick Warning
The Flick Warning provides a visible warning (by quickly flicking the lights on/off) that the scheduled end
time is approaching, and that the lights will be turning off.
Flick Duration
The Flick Duration determines how long before the scheduled end time the Flick Warning occurs.
Min ON Time
The Minimum On Time establishes the minimum time that the lights will remain on.
Max ON Time
The Maximum Off Time establishes the maximum time that the light will remain on.
Inputs setup
Page 14
GE Lighting Control
LightSweep CLCDLS
Programming Schedules
Date/Time
Time and date are set from a common page, easily accessed from the system home page.
To set or change the Time and Date:
4.
From the main screen, touch the Date/Time icon on the display.
5.
The Date/Time Setup page appears.
Page 15
GE Lighting Control
LightSweep CLCDLS
Schedule configuration
Selecting a Schedule
Schedules are selected from the Main Screen. There are eight schedules available, identified as A to H.
Active Schedules display their current status (On or Off) and the next time an On/Off event is scheduled
to occur.
Touch a Schedule to view the Schedule details and options.
Options:
•
Return to Main Screen
•
Targets
•
Exceptions
•
Look up
•
Cancel
Daily Schedule setup
When viewing a Schedule, the screen displays the current day’s Schedule. Swipe left or right to change
the day being displayed. There are seven pages, one for each day of the week.
To create a new Schedule:
Page 16
GE Lighting Control
LightSweep CLCDLS
6.
Touch an empty Schedule on the Main Screen.
7.
Swipe left or right to select the correct day in which to add the Schedule entry. For
Schedules entries that are expected to for multiple days, simply select one of the days.
8.
Touch Add.
9.
Select a start and end time.
10. Touch Save. The new Schedule entry is created.
Page 17
GE Lighting Control
LightSweep CLCDLS
To copy a Schedule entry to other days:
11. Select the desired Schedule entry.
12. Use the days of the week buttons along the bottom to select which days the Schedule
entry applies to. Select as many as necessary. Selecting the current day isn’t required.
13. Touch Copy to copy the Schedule entry to the selected days.
To edit a schedule entry:
14. Select the desired Schedule entry.
Page 18
GE Lighting Control
LightSweep CLCDLS
15. Touch Edit.
16. Make changes as needed. Touch Save.
Special days
Exceptions entries can be added to a schedule for days when the normal schedule entries should not
apply.
There are three types of exceptions that can be created.
•
Single Recurring Date
•
Date Range
•
Recurring Week/Day
To create an exception entry:
17. From the Schedule screen, touch the Exceptions button.
Page 19
GE Lighting Control
LightSweep CLCDLS
18. The Schedule Exceptions screen appears.
19. Touch Add
20. Select the Exception type by swiping left or right.
•
Single/Recurring Date – Best used an exception that applies on a specific day. Either a day
each month, or a day every year. For example, a Christmas Schedule can be set up to
th
apply every December 25 .
Page 20
GE Lighting Control
•
LightSweep CLCDLS
Date Range – Used for exceptions that apply for a specific amount of time. Both a start
and end date must be defined. For example, an exception could be created for a
temporary closure.
•
Recurring Week/Day – Used for exceptions which occur on specific days (not dates) of the
month. For example, an exception could be set up for every Monday in January.
•
Select a start and end time.
21. Touch Save.
To edit an Exception schedule:
22. Select an exception entry from the list.
23. Touch Edit and make the necessary changes. Then touch Save.
To delete an Exception entry:
24. Select an exception entry from the list.
Page 21
GE Lighting Control
LightSweep CLCDLS
25. Touch Delete.
Assign targets
To assign targets
26. Touch the Targets icon.
27. The Targets page appears.
Page 22
GE Lighting Control
LightSweep CLCDLS
28. Touch Add.
29. The Target Add page appears.
30. Select a target type, and touch Next.
Assign targets
RM
1.
Select RM
2.
Touch one or more Rly options to select it them.
Page 23
GE Lighting Control
3.
LightSweep CLCDLS
Use the Up/Down arrow to choose between the Standard ON/OFF, or scene control
On Only or Off Only.
4.
Touch Next
Astronomical –
The Astro settings allow the lights to be turned off/off with the Sunrise/Sunset
•
Toggling the Lights On/Off for either Sunrise or Sunset will automatically toggle the action of the
opposite setting.
Page 24
GE Lighting Control
•
LightSweep CLCDLS
Toggling the Lights On/Off for either Sunrise or Sunset will automatically toggle the action of the
opposite setting.
Sweep
•
When Sweep is On, it commands its target lights Off when the Sweep Time has elapsed, (if no
other control wants the lights on)