security technology
2013
security technology
intruder alarm systems s addressable fire alarm systems s conventional fire alarm systems
peace of mind
EN
2013-1 PRODUCT CATALOGUE
security technology
TEKNIM is an ISO 9001:2008 certificated manufacturer in security products market, located in Istanbul-Turkey .It has
its own Research & Development department and all its production facility is in Turkey.
TEKNIM, is a high-tech company which designs and produces alarm control panels, detectors, other fire detection and
intruder alarm products, sells both abroad and within the domestic markets through distributors & retailers. In this
area, especally in very advanced and complete alarm systems technology development, TEKNIM is one of the biggest
company in Turkey in terms of design and production.
Although TEKNIM is a very young company, in Turkish market, it has left behind the world leading brands and gained
confidence of hundreds of companies and alarm systems consumers in a very short period and has a significant
market share and growth since then.
TEKNIM, besides intruder alarm systems ,also design and manufactures fire detection systems from 2008 and on.
Produced by TEKNIM, fire alarm panels and other fire products are being very much appreciated by consumers as well
as industry professionals.
TEKNIM, Turkey's one of the leading manufacturer of alarm systems, is the only exporter of bearing its name as
TEKNIM and has become one of the most important brands.
In addition to the domestic success, TEKNIM products are being exported to many countries in Europe, Africa and
Asia.
TEKNIM, as a manufacturer of intruder alarm systems and fire alarm systems, proudly represents our country in
abroad with the TEKNIM brand with an ongoing success.
Contents:
INTRUDER ALARM SYSTEMS . . . 2
Alarm Panels ...............................................6
Alarm Keypads ..........................................16
Optional Modules.......................................19
PIR Detectors ............................................23
Smoke Detectors .......................................26
Gas Detectors............................................27
Other Detectors .........................................28
Outdoor & Indoor Sirens ............................30
CONTINUOUS POWER
SUPPLIES . . . . . . . . . . . . . . . . . 32
CONVENTIONAL FIRE
ALARM SYSTEMS. . . . . . . . . . . 33
Fire Alarm Panels ......................................34
Fire Detectors ............................................37
Indoor Fire Sirens & Strobes .....................39
Outdoor Fire Sirens & Gas Detectors ........40
www.teknim.com | sales@teknim.com
To be surrounded by wire fences...
Is it enough for your safety?
INTRUDER ALARM SYSTEMS
What can you do with VAP Series Alarm Panels?
Whether you are at home or not, YOU CAN...
...turn on the heater and have your home warm in cold winter days
before you arrive home,
...run the irrigation system
...turn on the oven to make your meal ready
at the time you arrive home,
... or shut the window shades.
Teknim Security Technology, as one of the leading manufacturers of security sector in
Turkey, we work for your life to be easier so you have more spare time for your beloved ones...
You ensure your security with aesthetic, strong and easy to use high technology Teknim
products, you don't even have to get up from where you sit...
Anywhere in the World, the only thing you need is a mobile phone or a computer...
4
6
VAP Series Alarm Panels with Plastic Box
PCB:
- Eco-friendly production techniques
- Lead-free material
- Microprocessor design
- Advanced features
- High performance, low error range
FUSED CONNECTOR:
- Simple connection and protected connection node
TAMPER SWITCH:
- Forth/back tamper switch protection against cover removal or
back case removal
PLASTIC BOX:
- High quality, resistant to damage, lead-free and strong case
ADAPTER:
- Efficient, SMPS
BATTERY:
- 12V 7AH battery slot
CONNECTION DUCTS:
- Easy to connect cables that came outside panel trough the
openings
ZONEx2
x2
Zone Doubling
Min 7 standart
users + 1 guest
user password
2 or more keypad
connections
supported
256
Event log memory
with 256 date and
time information
Dialer
SPT
Smart
Partitioning
Technology
Contact ID
communicator
5
Alarm Panels
Intruder Alarm Sytems
One panel, four independent systems
Especially for small and medium sized residental and commercial
areas, this feature lets the users divide the area up to 4 separate
parts and use each part as compeletely independent systems via
4 separate keypads. Each keypad has its own address and they do
not effect each other.
Conventional Fire Alarm Systems
Users can arm/disarm each partition separately or together.
Keypads, partitions, sirens, phone numbers and authorizations of
users can be assigned independently.
VAP-416 M
Alarm Panel
VAP-416 Alarm Control Panel is the perfect high-end security and
automation solution for medium and large sized residential and commercial
areas. It is not only an alarm panel but also an automation system with 3 PGM
outputs and periodic timers. Users may activate an electronic system such as
irrigation system, air-condition, oven etc. in a determined time period by
using PGM output.
Users may arm/disarm panel and control PGM outputs remotely by phone.
VAP-416 Alarm Control Panel can be controlled and monitored locally or
remotely from a local PC or network/internet PC via VAPMAN Alarm
Management Software. Its easy installation and user-friendly usage make it
attractive both for installers and end users.
Metal box only
General Features
16 + 16 zones
• 16 zones on main control panel, expandable to 20 zones with
optional zone expansion module and to 32 zones with hardwire
zone-doubling
• Using each zone with NC or NO contacts devices with or
without EOL resistors
• Selecting each zone as 12 different type (door, window, home,
away, 24 hours, fire, tamper, panic…etc.)
• Entry/Exit delays for each partition
• Adjustable zone response speed
• Additional features of the zones (Entry/exit zone, follower
zone, last-door zone, zone with audio / silent…etc.)
• Arming panel automatically without delay time by determining
Entry/Exit zones, when someone exits from last-door
• Adjusting each zone as special zone in order to transmit alarm
message to the central station without alarm siren (for gas
detectors, flood detectors)
6
• Selectable cross zone and double hit features to avoid from false
alarm
• Walking test for each zone
• Bypassing each zone manually or automatically
Outputs
• 1 siren output
- Negative or positive trigger
- Adjusting cut off time between 2 to 255 min
• 3 programmable outputs
- Can be increased to 8 PGM outputs with optional PGM relay
module
- Can be used as siren output
- Can be used as arm output
- Can be used as fire siren output
- Can be used as being active when determined zones are armed
www.teknim.com | sales@teknim.com
4 Partitions
• Arming/disarming each partition together or separately
• Smart Partition Technology; zones are automatically assigned to
the related partitions
• Using each partition as independent systems (keypad, zone,
phone numbers, siren, users can be assigned independently)
4 Keypads Connection
• Each keypad has its own address. Keypads do not affect each
other
• Connecting LED and LCD keypads to the panel separately or
together
• Showing the motions only in specific zones by assigned
partitions to the keypads
• One key quick arming, partial arming (away, home, doors,
windows... etc.) for each partition, by four special keys on the
keypads
• Producing warning sound (chime) by buzzer, when the specific
zones become active or inactive
• Automatic light activation of the determined zones (For
example; when user opens the door, the keypad automatically
illuminates)
Power Supply
• Short circuit protected 12V output (total 2A)
• Extra auxiliary power for the siren
• Extra auxiliary power for the keypad
• Current limited battery charge circuit
• Continuously mains power and battery check
256 event log memory with date and time information
Communication by PC
• Reading, setting and controlling all panel settings and reading
event log memory from a local PC via optional link modules VPL232, VPL-USB; from a remote PC via onboard modem or from
local network/internet via optional network module VPL-NET by
using VAPMAN Alarm Management Software
• Monitoring (zone, PGM or panel status) and controlling
(arming/disarming, controlling of PGM outputs) panel from local
PC via optional link modules VPL-232, VPL-USB, from remote
PC via onboard modem or local network/internet via optional
network module VPL-NET by using VAPMAN alarm
management software
Controlling remotely by phone
• Arming/disarming of the panel
• Controlling of PGM outputs
• Getting information about panel status or PGM status
Communicator
• Including Contact ID and SIA formats
• Calling 6 different private phone numbers (users)
- Ability to deliver standard alarm warning signal
- Ability to deliver voice message on any alarm by voice
recording module VAV-210 or voice message module VAV- 218
• Calling 2 different central stations with secondary numbers
• One key confirmation on incoming calls
• Selecting communicator messages
• Events which will be sent to the private phones can be selected
• Sending delayed power failure report
• Continuously telephone line check and alarms on lined failure
• Distributing each private phone numbers and CMS numbers for
related partitions
Users
• Installer code: Able to command all settings related with
installation
• Master code: Able to command all settings related with users
(Code, time setting... etc)
• 27 user codes: Able to command arming/disarming of the panel
- User authorization can be limited for determined time and
operation
• Temporary guest code: Has normal user rights for a day or one
time usage
• Duress code: Able to disarm the panel but the central stations and
users are called
• PC access code: Able to control the panel via VAPMAN
management software
Arming/disarming alternatives
• Partial arming/disarming
• Automatic arming/disarming for a determined date and time
period
• Arming/disarming by remote controller
• Arming/disarming by phone
• Arming/disarming by VAPMAN alarm management software
• Inactivity arming within entered time period
Conventional Fire Alarm Systems
- Can be adjusted to output randomly
- Can be used as selectable trouble output
- Can be used as smoke detector power (for automatic
resetting)
Intruder Alarm Sytems
Alarm Panels
2 periodic timers
• Can be used to control PGMs for determined hours and days
Additional and optional modules
• 4 zone expansion module (VAG-204)
• Voice recording module (VAV-210)
• 4 PGM relay module (TRM-904)
• Network module (TPL-NET)
• RS 232 Serial Communication Module (VPL-232)
• USB Serial Communication Module (VPL-USB)
• Remote control module (VAR-145)
Keypad access limitation
• As showing only determined partitions
• As arming
• As disarming
• As accessing the programming
Access control system
• Using panel as an access control system for a door by connecting
additional keypad to the door and assigning one user password and
one PGM
• Limiting access for determined date and time period
Recommended keypads
• VPC-350 Touch Screen keypad
• VPC-301 LCD keypad
• VPC-132 LED keypad
• VPC-116 LED keypad (in the use of double zone feature, only
supported zones can be seen)
www.teknim.com | sales@teknim.com
7
Alarm Panels
Intruder Alarm Sytems
VAP-408 M / P
Alarm Panel
VAP-408 Alarm Control Panel is the perfect high-end security and
automation solution for medium and large sized residential and commercial
areas. It is not only an alarm panel but also an automation system with 3 PGM
outputs and periodic timers. Users may activate an electronic system such as
irrigation system, air-condition, oven etc. in a determined time period by
using PGM output.
Users may arm/disarm panel and control PGM outputs remotely by phone.
VAP-408 Alarm Control Panel can be controlled and monitored locally or
remotely from a local PC or network/internet PC via VAPMAN Alarm
Conventional Fire Alarm Systems
Management Software. Its easy installation and user-friendly usage make it
attractive both for installers and end users.
M: Metal box / P: Plastic box
General Features
8 + 8 zones
• 8 zones on main control panel, expandable to 12 zones with
optional zone expansion module and to 16 zones with hardwire
zone-doubling
• Using each zone with NC or NO contacts devices with or
without EOL resistors
• Selecting each zone as 12 different type (door, window, home,
away, 24 hours, fire, tamper, panic…etc.)
• Entry/Exit delays for each partition
• Adjustable zone response speed
• Additional features of the zones (Entry/exit zone, follower
zone, last-door zone, zone with audio / silent…etc.)
• Arming panel automatically without delay time by determining
Entry/Exit zones, when someone exits from last-door
• Adjusting each zone as special zone in order to transmit alarm
message to the central station without alarm siren (for gas
detectors, flood detectors)
• Selectable cross zone and double hit features to avoid from
false alarm
• Walking test for each zone
• Bypassing each zone manually or automatically
Outputs
• 1 siren output
- Negative or positive trigger
- Adjusting cut off time between 2 to 255 min
• 3 programmable outputs
-Can be increased to 8 PGM outputs with optional PGM relay
module
- Can be used as siren output
- Can be used as arm output
- Can be used as fire siren output
- Can be used as being active when determined zones are
armed
- Can be adjusted to output randomly
- Can be used as selectable trouble output
- Can be used as smoke detector power (for automatic
resetting)
8
- Can be used as being active when there is a motion in
determined zones or partitions
- Can be used as being active in assigned time period
- Can be used as magnetic or electro mechanic door lock
controller output when using access control feature
4 Partitions
• Arming/disarming each partition together or separately
• Smart Partition Technology; zones are automatically assigned to
the related partitions
• Using each partition as independent systems (keypad, zone, phone
numbers, siren, users can be assigned independently)
4 Keypads Connection
• Each keypad has its own address. Keypads do not affect each other
• Connecting LED and LCD keypads to the panel separately or
together
• Showing the motions only in specific zones by assigned partitions
to the keypads
• One key quick arming, partial arming (away, home, doors,
windows... etc.) for each partition, by four special keys on the
keypads
• Producing warning sound (chime) by buzzer, when the specific
zones become active or inactive
• Automatic light activation of the determined zones (For example;
when user opens the door, the keypad automatically illuminates)
Power Supply
• Short circuit protected 12V output (total 1A)
• Extra auxiliary power for the siren
• Extra auxiliary power for the keypad
• Current limited battery charge circuit
• Continuously mains power and battery check
256 event log memory with date and time information
Communication by PC
• Reading, setting and controlling all panel settings and reading event
www.teknim.com | sales@teknim.com
Alarm Panels
Communicator
• Including Contact ID and SIA formats
• Calling 6 different private phone numbers (users)
- Ability to deliver standard alarm warning signal
- Ability to deliver voice message on any alarm by voice
recording module VAV-210 or voice message module VAV- 218
• Calling 2 different central stations with secondary numbers
• One key confirmation on incoming calls
• Selecting communicator messages
• Events which will be sent to the private phones can be selected
• Sending delayed power failure report
• Continuously telephone line check and alarms on lined failure
• Distributing each private phone numbers and CMS numbers
for related partitions
Users
• Installer code: Able to command all settings related with
installation
• Master code: Able to command all settings related with users
(Code, time setting... etc)
• 9 user codes: Able to command arming/disarming of the panel
- User authorization can be limited for determined time and
operation
• Temporary guest code: Has normal user rights for a day or one
time usage
• Duress code: Able to disarm the panel but the central stations
and users are called
Arming/disarming alternatives
• Arming/disarming by a key
• Partial arming/disarming
• Automatic arming/disarming for a determined date and time
period
• Arming/disarming by remote controller
• Arming/disarming by phone
• Arming/disarming by VAPMAN alarm management software
• Inactivity arming within entered time period
2 periodic timers
• Can be used to control PGMs for determined hours and days.
Additional and optional modules
• 4 zone expansion module (VAG-204)
• Voice recording module (VAV-210)
•4 PGM relay module (TRM-904)
• Network module (TPL-NET)
• RS 232 Serial Communication Module (VPL-232)
• USB Serial Communication Module (VPL-USB)
• Remote control module (VAR-145)
Keypad access limitation
• As showing only determined partitions
• As arming
• As disarming
• As accessing the programming
Intruder Alarm Sytems
Controlling remotely by phone
• Arming/disarming of the panel
• Controlling of PGM outputs
• Getting information about panel status or PGM status
• PC access code: Able to control the panel via VAPMAN
management software
Conventional Fire Alarm Systems
log memory from a local PC via optional link modules VPL-232,
VPL-USB; from a remote PC via onboard modem or from local
network/internet via optional network module VPL-NET by
using VAPMAN Alarm Management Software
• Monitoring (zone, PGM or panel status) and controlling
(arming/disarming, controlling of PGM outputs) panel from local
PC via optional link modules VPL-232, VPL-USB, from remote
PC via onboard modem or local network/internet via optional
network module VPL-NET by using VAPMAN alarm
management software
Access control system
• Using panel as an access control system for a door by connecting
additional keypad to the door and assigning one user password and
one PGM
• Limiting access for determined date and time period.
Recommended keypads
• VPC-350 Touch Screen keypad
• VPC-301 LCD keypad
• VPC-116 LED keypad
• VPC-108 LED keypad (in the use of double zone feature, only
supported zones can be seen)
All Teknim Alarm Panels connect to a central monitoring station
(CMS) or defined users via landline phone. In case of alarm,
communicator delivers event codes with Contact ID protocol to
CMS and standart alarm warning signal to defined users, at the
same time.
Advanced
built-in dialer
By using optional Voice Recording Module* users can record their
own voice and recieve this recorded message instead of standart
alarm warning signal.
On VAP-400 series alarm panels, users have the ability to dial the
alarm panel via its phone line during an event or any regular time
they want. Just by pressing on buttons of the phone, users can
arm/disarm the panel or manage the programmable outputs.
* For more information please refer to page
www.teknim.com | sales@teknim.com
9
Alarm Panels
Conventional Fire Alarm Systems
Intruder Alarm Sytems
Especially for small sized residental areas, selecting smart partition feature,
zones are automatically assigned to the related partitions as windows, doors,
home & away.
With one key quick arming you can arm/disarm your system compeletely or
partially (away, home, doors, windows...etc.) by four special keys on the
keypads.
A (home)
B (windows)
C (doors)
D (away)
VAP-404 M / P
Smart partitioning technology
Alarm Panel
VAP-404 Alarm Control Panel is the perfect security solution for small and
medium sized residential and commercial areas. It is not only an alarm panel
but also an automation system with 2 PGM outputs and periodic timers.
Users may activate an electronic system such as irrigation system, aircondition, oven etc. in a determined time period by using PGM output.
Users may arm/disarm panel and control PGM outputs remotely by phone.
VAP-404 Alarm Control Panel can be controlled and monitored locally or
remotely from a local PC or network/internet PC via VAPMAN Alarm
Management Software. Its easy installation and user-friendly usage make it
attractive both for installers and end users.
M: Metal box / P: Plastic box
General Features
4 + 4 zones
• 4 zones on main control panel, expandable to 8 zones with
hardwire zone-doubling or optional zone expansion module
• Using each zone with NC or NO contacts devices with or
without EOL resistors
• Selecting each zone as 12 different type (door, window, home,
away, 24 hours, fire, tamper, panic…etc.)
• Entry/Exit delays for each partition
• Adjustable zone response speed
• Additional features of the zones (Entry/exit zone, follower
zone, last-door zone, zone with audio / silent…etc.)
• Arming panel automatically without delay time by determining
Entry/Exit zones, when someone exits from last-door
• Adjusting each zone as special zone in order to transmit alarm
message to the central station without alarm siren (for gas
detectors, flood detectors)
• Selectable cross zone and double hit features to avoid from
false alarm
• Walking test for each zone
• Bypassing each zone manually or automatically
10
Outputs
• 1 siren output
- Negative or positive trigger
- Adjusting cut off time between 2 to 255 min
• 2 programmable outputs
- Can be increased to 8 PGM outputs with optional PGM relay
module.
- Can be used as siren output
- Can be used as arm output
- Can be used as fire siren output
- Can be used as being active when determined zones are armed
- Can be adjusted to output randomly
- Can be used as selectable trouble output
- Can be used as smoke detector power (for automatic resetting)
- Can be used as being active when there is a motion in
determined zones or partitions
- Can be used as being active in assigned time period
- Can be used as magnetic or electro mechanic door lock
controller output when using access control feature
• 1 armed output
www.teknim.com | sales@teknim.com
1 key Input
• Being armed in toggle or level mode
4 Partitions
• Arming/disarming each partition together or separately
• Smart Partition Technology; zones are automatically assigned to
the related partitions
• Using each partition as independent systems (keypad, zone,
phone numbers, siren, users can be assigned independently)
4 Keypads Connection
• Each keypad has its own address. Keypads do not affect each
other
• Connecting LED and LCD keypads to the panel separately or
together
• Showing the motions only in specific zones by assigned
partitions to the keypads
• One key quick arming, partial arming (away, home, doors,
windows... etc.) for each partition, by four special keys on the
keypads
• Producing warning sound (chime) by buzzer, when the specific
zones become active or inactive
• Automatic light activation of the determined zones (For
example; when user opens the door, the keypad automatically
illuminates)
Power Supply
• Short circuit protected 12V output (total 1A)
• Extra auxiliary power for the siren
• Extra auxiliary power for the keypad
• Current limited battery charge circuit
• Continuously mains power and battery check
• One key confirmation on incoming calls
• Selecting communicator messages
• Events which will be sent to the private phones can be selected
• Sending delayed power failure report
• Continuously telephone line check and alarms on lined failure
• Distributing each private phone numbers and CMS numbers for
related partitions
Users
• Installer code: Able to command all settings related with
installation
• Master code: Able to command all settings related with users.
(Code, time setting... etc)
• 5 user codes: Able to command arming/disarming of the panel.
- User authorization can be limited for determined time and
operation
• Temporary guest code: Has normal user rights for a day or one
time usage
• Duress code: Able to disarm the panel but the central stations and
users are called
• PC access code: Able to control the panel via VAPMAN
management software
Arming/disarming alternatives
• Arming/disarming by a key
• Partial arming/disarming
• Automatic arming/disarming for a determined date and time
period
• Arming/disarming by remote controller
• Arming/disarming by phone
• Arming/disarming by VAPMAN alarm management software
• Inactivity arming within entered time period
Conventional Fire Alarm Systems
- Being active or inactive when the assigned partitions armed.
Intruder Alarm Sytems
Alarm Panels
2 periodic timers
• Can be used to control PGMs for determined hours and days
256 event log memory with date and time information.
Communication by PC
• Reading, setting and controlling all panel settings and reading
event log memory from a local PC via optional link modules VPL232, VPL-USB; from a remote PC via optional modem module
TPL-MDM or from local network/internet via optional network
module TPL-NET by using VAPMAN Alarm Management
Software
• Monitoring (zone, PGM or panel status) and controlling
(arming/disarming, controlling of PGM outputs) panel from local
PC via optional link modules VPL-232, VPL-USB, from remote
PC via optional modem module TPL-MDM or local
network/internet via optional network module TPL-NET by
using VAPMAN alarm management software
Controlling remotely by phone
• Arming/disarming of the panel
• Controlling of PGM outputs
• Getting information about panel status or PGM status
Communicator
• Including Contact ID, DTMF 3+1, 3+2, 4+1, 4+2 formats
• Calling 6 different private phone numbers (users)
- Ability to deliver standard alarm warning signal
- Ability to deliver voice message on any alarm by voice
recording module VAV-210 or voice message module VAV- 218
• Calling 2 different central stations with secondary numbers
Additional and optional modules
• 4 zone expansion module (VAG-204)
• Voice recording module (VAV-210)
• 4 PGM relay module (TRM-904)
• Network module (TPL-NET)
• RS 232 Serial Communication Module (VPL-232)
• USB Serial Communication Module (VPL-USB)
• Remote control module (VAR-145)
• Modem Module (TPL-MDM)
Keypad access limitation
• As showing only determined partitions
• As arming
• As disarming
• As accessing the programming
Access control system
• Using panel as an access control system for a door by connecting
additional keypad to the door and assigning one user password and
one PGM
• Limiting access for determined date and time period.
Recommended keypads
• VPC-350 Touch Screen keypad
• VPC-301 LCD keypad
• VPC-108 LED keypad
www.teknim.com | sales@teknim.com
11
Alarm Panels
Intruder Alarm Sytems
VAP-308 M / P
Alarm Panel
VAP-308 Alarm Control Panel is the perfect security solution for medium and
large sized residential and commercial areas. It is not only an alarm panel but
also an automation system with PGM output and periodic timers.
Users may activate an electronic system such as irrigation system, aircondition, oven etc. in a determined time period by using PGM output. VAP308 Alarm Control Panel can be controlled and monitored locally or
remotely from a local PC or network/internet PC via VAPMAN Alarm
Management Software. Its easy installation and user-friendly usage make it
Conventional Fire Alarm Systems
attractive both for installers and end users.
M: Metal box / P: Plastic box
General Features
8 + 8 zones
• 8 zones on main control panel, expandable to 12 zones with
optional zone expansion module and to 16 zones with hardwire
zone-doubling
• Using each zone with NC or NO contacts devices with or
without EOL resistors
• Selecting each zone as 12 different type (door, window, home,
away, 24 hours, fire, tamper, panic…etc.)
• Entry/Exit delays for each partition
• Adjustable zone response speed
• Additional features of the zones (Entry/exit zone, follower
zone, last door zone, zone with audio / silent…etc.)
• Arming panel automatically without delay time by determining
Entry/Exit zones, when someone exits from last-door
• Adjusting each zone as special zone in order to transmit alarm
message to the central station without alarm siren (for gas
detectors, flood detectors)
• Selectable cross zone and double hit features to avoid from
false alarm
• Walking test for each zone
• Bypassing each zone manually or automatically
Outputs
• 1 siren output
- Negative or positive trigger
- Adjusting cut off time between 2 to 255 min
• 1 programmable output
- Can be used as siren output
- Can be used as arm output
- Can be used as fire siren output
- Can be used as selectable trouble output
- Can be used as smoke detector power (for automatic
resetting)
- Can be used as being active when there is a motion in
determined zones
- Can be used as being active in assigned time period
12
2 Keypads can be connected
• Each keypad has its own address. Keypads do not affect each other
• Connecting LED and LCD keypads to the panel separately or
together
• Producing warning sound (chime) by buzzer, when the specific
zones become active or inactive
• Automatic light activation of the determined zones (For example;
when user opens the door, the keypad automatically illuminates)
Power Supply
• Short circuit protected 12V output (total 1A)
• Extra auxiliary power for the siren
• Extra auxiliary power for the keypad
• Current limited battery charge circuit
• Continuously mains power and battery check
256 event log memory with date and time information.
Communication by PC
• Reading, setting and controlling all panel settings and reading event
log memory from a local PC via optional link modules VPL-232, VPLUSB; from a remote PC via optional modem module TPL-MDM or
from local network/internet via optional network module TPL-NET
by using VAPMAN Alarm Management Software
• Monitoring (zone, PGM or panel status) and controlling
(arming/disarming, controlling of PGM outputs) panel from local PC
via optional link modules VPL-232, VPL-USB, from remote PC via
optional modem module VPL-MDM or local network/internet via
optional network module VPL-NET by using VAPMAN alarm
management software
Communicator
• Including Contact ID , DTMF 3+1, 3+2, 4+1, 4+2 formats
• Calling 6 different private phone numbers (users)
- Ability to deliver standard alarm warning signal
- Ability to deliver voice message on any alarm by voice recording
module VAV-210 or voice message module VAV-218
www.teknim.com | sales@teknim.com
Alarm Panels
Arming/disarming alternatives
• Arming/disarming by a key
• Automatic arming/disarming for a determined date and time
period
• Arming/disarming by remote controller
2 weekly timers
• Can be used to control PGMs
Additional and optional modules
• 4 zone expansion module (VAG-204)
• Voice recording module (VAV-210)
• RS 232 Serial Communication Module (VPL-232)
• USB Serial Communication Module (VPL-USB)
• Network module (TPL-NET)
• Modem Module (TPL-MDM)
• Remote control module (VAR-145)
Recommended keypads
• VPC-301 LCD keypad
• VPC-016 LED keypad
• VPC-116 LED keypad
• VPC-108 LED keypad (in the use of double zone feature only
supported zones can be seen)
• VPC-104 LED keypad (in the use of double zone feature, only
supported zones can be seen)
Intruder Alarm Sytems
Users
• Installer code: Able to command all settings related with
installation
• Master code: Able to command all settings related with users.
(code, time setting.. etc)
• 9 user codes: Able to command arming/disarming of the panel.
- User authorization can be limited for determined time and
operation
• Temporary guest code: Has normal user rights for a day or one
time usage
• Duress code: Able to disarm the panel but the central stations
and users are called
• PC access code: Able to control the panel via VAPMAN
management software
• Arming/disarming by VAPMAN alarm management software
• Inactivity arming within entered time period
Conventional Fire Alarm Systems
• Calling a central station with secondary number
• Selecting communicator messages
• Selecting events which will be sent to the private phones
• Delayed power failure report
Life saving DURESS CODE
What if someone follows you up to your house and forces you to disable your burglar alarm system?
When you dial the duress code, your home security system disarms as usual but at the same time it sends a silent alarm to the
central monitoring station, advising that you are in duress. Since central monitoring station is notified about the type of alarm which
is activated, they take the duress alarm with even more intensity than a regular alarm.
General features of Teknim Alarm Panels:
Arming/disarming the panel via phone/PC.
Getting information about panel status or PGM status, remotely by
phone/PC.
t Automatic arming/disarming for a determined time period.
t Using outdoor siren as a warning system with high sound level and flasher.
t Alarm panel may also run a fire alarm panel with smoke detectors*.
t Via a local or remote PC, users can control and observe all panel settings,
monitor all panel status.
t Users can be allowed or/and restricted on specified;
-Keypads,
-Date/time periods,
-Partitions,
-Operations (arm, disarm, bypass)
t
t
* Please refer to page 34.
www.teknim.com | sales@teknim.com
13
Alarm Panels
Intruder Alarm Sytems
VAP-304 M / P
Alarm Panel
VAP-304 Alarm Control Panel is the perfect security solution for small and
medium sized residential and commercial areas. It is not only an alarm panel
but also an automation system with PGM output and periodic timers.
Users may activate an electronic system such as irrigation system, aircondition, oven etc. in a determined time period by using PGM output. VAP304 Alarm Control Panel can be controlled and monitored locally or
remotely from a local PC or network/internet PC via VAPMAN Alarm
Management Software. Its easy installation and user-friendly usage make it
Conventional Fire Alarm Systems
attractive both for installers and end users.
M: Metal box / P: Plastic box
General Features
4 + 4 zones
• 4 zones on main control panel, expandable to 8 zones with
hardwire zone-doubling or optional zone expansion module
• Using each zone with NC or NO contacts devices with or
without EOL resistors
• Selecting each zone as 12 different type (door, window, home,
away, 24 hours, fire, tamper, panic…etc.)
• Entry/Exit delays for each partition
• Adjustable zone response speed
• Additional features of the zones (Entry/exit zone, follower
zone, last-door zone, zone with audio / silent…etc.)
• Arming panel automatically without delay time by determining
Entry/Exit zones, when someone exits from last-door
• Adjusting each zone as special zone in order to transmit alarm
message to the central station without alarm siren (for gas
detectors, flood detectors)
• Selectable cross zone and double hit features to avoid from
false alarm
• Walking test for each zone
• Bypassing each zone manually or automatically
Outputs
• 1 siren output
- Negative or positive trigger
- Adjusting cut off time between 2 to 255 min
• 1 programmable output
- Can be used as siren output
- Can be used as arm output
- Can be used as fire siren output
- Can be used as selectable trouble output
- Can be used as smoke detector power (for automatic
resetting)
- Can be used as being active when there is a motion in
determined zones
- Can be used as being active in assigned time period
Power Supply
• Short circuit protected 12V output (total 1A)
14
• Extra auxiliary power for the siren
• Extra auxiliary power for the keypad
• Current limited battery charge circuit
• Continuously mains power and battery check
256 event log memory with date and time information
Communication by PC
• Reading, setting and controlling all panel settings and reading event
log memory from a local PC via optional link modules VPL232, VPL-USB; from a remote PC via optional modem module TPLMDM or from local network/internet via optional network module
TPL-NET by using VAPMAN Alarm Management Software
• Monitoring (zone, PGM or panel status) and controlling
(arming/disarming, controlling of PGM outputs) panel from local PC
via optional link modules VPL-232, VPL-USB, from remote PC via
optional modem module TPL-MDM or local network/internet via
optional network module TPL-NET by using VAPMAN alarm
management software
Communicator
• Including Contact ID , DTMF 3+1, 3+2, 4+1, 4+2 formats
• Calling 6 different private phone numbers (users)
- Ability to deliver standard alarm warning signal
- Ability to deliver voice message on any alarm by voice recording
module VAV-210 or voice message module VAV-218
• Calling a central station with secondary number
• Selecting communicator messages
• Selecting events which will be sent to the private phones
• Delayed power failure report
Users
• Installer code: Able to command all settings related with
installation.
• Master code: Able to command all settings related with users
(code, time setting.. etc)
• 5 user codes: Able to command arming/disarming of the panel
-User authorization can be limited for determined time and
www.teknim.com | sales@teknim.com
Alarm Panels
Intruder Alarm Sytems
Arming/disarming alternatives
• Arming/disarming by a key
• Automatic arming/disarming for a determined date and time
period
• Arming/disarming by remote controller
• Arming/disarming by VAPMAN alarm management software
• Inactivity arming within entered time period
Additional and optional modules
• 4 zone expansion module (VAG-204)
• Voice recording module (VAV-210)
• RS 232 Serial Communication Module (VPL-232)
• USB Serial Communication Module (VPL-USB)
• Network module (TPL-NET)
• Modem module (TPL-MDM)
• Remote control module (VAR-145)
Recommended keypads
• VPC-301 LCD keypad
• VPC-108 LED keypad
• VPC-104 LED keypad
2 weekly timers
• Can be used to control PGMs
Features
Zone+Zone doubling
EOL resistor connection
Connection option (NC,NO)
Zone determination (fire, 24 hours, tamper...etc)
Cross Zone and Double hit
Walking Test
Adjustable zone detection time
Restriction of user authorization
Programmable outputs
Arm output
Key Input
Partition
Smart Partition Technology (SPT)
Partial arming
Entry/Exit delays for each partition
Automatic and manual by-pass
Supported keypad connection
Event log memory
Line input /phone output
Remotely control by phone
Communicator
Dialer
Supported communication format
User codes including master, installer, and PC
access code
Duress and Guest codes
Time managed arming/disarming
Arming/disarming by a key
Partition management by a key
Event code selection for communicator
Access control system
Remotely upload and download
Monitoring and control from internet
VAPMAN Alarm Management Software
NC/NO options for siren and PGM outputs
Continuously mains power and battery and check
Continuously phone line check
Voice recording module
Remote controlling module
Zone expansion module
4 PGM Relay Module
PC link modules (RS232, USB)
Network module
Modem module
Wireless Zone Module
Adjustable siren cut off time
VAP-304 P/M
VAP-308 P/M
VAP-404 P/M
4+4
8+8
4+4
0,1 or 2
0,1 or 2
0,1 or 2
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
1
1
2
with PGM
with PGM
Yes
No
No
Yes
1
1
4
No
No
Yes
No
No
Yes
No
No
Yes
Yes
Yes
Yes
2
2
4
256
256
256
Yes
Yes
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Contact ID, DTMF 3+1, 3+2, 4+1, 4+2
8
12
8
VAP-408 P/M
Yes
Yes
Yes
No
Yes
No
Optional
Optional
Standard
Yes
Yes
No
Optional
Optional
+4(optional)
No
Optional
Optional
No
Optional
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Standard
Optional
Standard
Yes
Yes
Yes
Optional
Optional
+4(optional)
Optional
Optional
Optional
On board
Optional
Yes
Yes
Yes
Yes
No
Yes
No
Optional
Optional
Standard
Yes
Yes
No
Optional
Optional
+4(optional)
No
Optional
Optional
Optional
Optional
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Optional
Optional
Standard
Yes
Yes
Yes
Optional
Optional
+4(optional)
Optional
Optional
Optional
Optional
Optional
Yes
www.teknim.com | sales@teknim.com
VAP-416
16+16
8+8
0,1 or 2
0,1 or 2
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
3
3
with PGM
with PGM
No
No
4
4
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
4
4
256
256
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Contact ID and SIA
32
12
Conventional Fire Alarm Systems
operation
• Temporary guest code: Has normal user rights for a day or one
time usage
• Duress code: Able to disarm the panel but the central stations
and users are called
• PC access code: Able to control the panel via VAPMAN
management software
Yes
Yes
Yes
Yes
Yes
Yes
Standard
Optional
Standard
Yes
Yes
Yes
Optional
Optional
+4(optional)
Optional
Optional
Optional
On board
Optional
Yes
15
Alarm Keypads
Conventional Fire Alarm Systems
Intruder Alarm Sytems
VPC-301B
LCD Alarm Keypad
VPC-301 LCD Keypad has been designed to control all
VAP series alarm panels. It can be adopted to all
decorations with its esthetic design.
t Programmable zone names
t Smoke detector reset connected to the PGM by keypad
t Backlit, two lines, 32 character LCD screen
t Special keys for panic, fire and duress alarm
t Adopted with all VAP Series Panels. It can be used with
t Energy saving mode for energy cutting
other VAP series keypads
t Backlit, multi-functional silicone keys
t Backlighting boost
t 4 special buttons for each partition for quick & partial
arm with backlight and activation light
t Internal buzzer
t Ability to read event log
t Automatic key light when a motion detected in a
determined zone
t Chime feature (warning with sound and light when the
determined zones active or inactive)
t Auto protection for wrong passwords entered 5 times.
VPC-132
t Sabotage switch (no need additional cable)
t On screen programming
t Alternately on screen thermometer/time/date and auxiliary
texts
t Easy programming by menu system
t Multi-language support
t Menu system, short keys and direction keys for easy
programming
t Two different keypad lights: Green (standard), Blue (optional)
LED Alarm Keypad
VPC-132 thirty two-zone is esthetic and smart LED
keypad has been designed to control VAP series alarm
panels. It is possible to control all features of VAP series
alarm panels by VPC-132.
t Backlit, multi-functional silicone keys
t Energy saving mode for mains failure
t Adopted with all VAP Series Panels with 4-32 zones. It
t Automatic key light when a motion detected in a determined
can be used with other VAP series keypads (except VPC104 and VPC-016) at the same panel
t Backlit 4 partition zone designed for partial arm with a
key
t Different led for each zone
t Internal buzzer
t Ability to read event log
t Special keys for panic, fire and duress alarm
16
zone
t Chime feature (warning with sound and light when the
determined zones active or inactive)
t Auto protection for wrong passwords entered 5 times
t Smoke detector reset connected to the PGM by keypad
t Sabotage switch (no need additional cable)
t Easy programming features
t Two different keypad light: Green (standard), blue (optional)
www.teknim.com | sales@teknim.com
Alarm Keypads
LED Alarm Keypad
Intruder Alarm Sytems
VPC-116 sixteen-zone is esthetic and smart LED keypad
has been designed to control all features of VAP series
alarm panels with 4-16 zones.
t Backlit, multi-functional silicone keys
t Energy saving mode for mains failure
t Adopted with all VAP Series Panels with 4-16 zones. It
t Automatic key light when a motion detected in a determined
can be used with other VAP series keypads (except VPC104) at the same panel
t Backlit 4 partition zone designed for partial arm with a
key
t Different led for each zone
t Internal buzzer
t Ability to read event log
t Special keys for panic, fire and duress alarm
zone
t Chime feature (warning with sound and light when the
determined zones active or inactive)
t Auto protection for wrong passwords entered 5 times
t Smoke detector reset connected to the PGM by keypad
t Sabotage switch (no need additional cable)
t Easy programming features
t Two different keypad light Green (standard), blue (optional)
VPC-108
Conventional Fire Alarm Systems
VPC-116
LED Alarm Keypad
VPC-108 eight-zone is esthetic and smart LED keypad has
been designed to control VAP series alarm panels with 4 to
8 zones.
t Backlit, multi-functional silicone keys
t Energy saving mode for mains failure
t Adopted with all VAP Series Panels have 4-8 zones. It
t Automatic key light when a motion detected in a determined
can be used with other VAP series keypads (except VPC104) at the same panel
t Backlit 4 partition zone designed for partial arm with a
key
t Different led for each zone
t Internal buzzer
t Ability to read event log
t Special keys for panic, fire and duress alarm
zone
t Chime feature (warning with sound and light when the
determined zones active or inactive)
t Auto protection for wrong passwords entered 5 times
t Smoke detector reset connected to the PGM by keypad
t Sabotage switch (no need additional cable)
t Easy programming features
t Two different keypad light Green (standard), blue (optional)
www.teknim.com | sales@teknim.com
17
Alarm Keypads
Conventional Fire Alarm Systems
Intruder Alarm Sytems
VPC-104
LED Alarm Keypad
VPC-104 eight-zone, functional, smart and economic
LED keypad have been designed to control all features of
the VAP-304 Alarm Panel.
t Backlit, multi-functional silicone keys.
t 7 segment red screens display the moving zones and
messages
t Internal buzzer
t Ability to read event log
t Special keys for panic, fire and duress alarm
t Energy saving mode for mains failure
t Automatic key light when a motion detected in a
determined zone
t Chime feature (warning with sound and light when the
determined zones active or inactive)
t Auto protection for wrong passwords entered 5 times
t Smoke detector reset connected to the PGM by keypad
t Sabotage switch (no need additional cable)
t Easy programming features
Features
VPC-104
VPC-108/116/132 VPC-301
Backlit, two lines, 32 character LCD screen
Backlit, long lived silicone keys
Backlighting boost
Back lighted 4 partition zone designed for partial arm with a key
Internal buzzer
Automatic key light when a motion detected in a determined zone
Chime feature (warning with sound and light when the determined zones active or inactive)
Special keys for panic, fire and duress alarm
Energy saving mode
Easy programming by menu system
Multi-language support
On screen thermometer/time/date
Auto protection for wrong passwords entered 5 times
7 Segment LED screen
No
Yes
No
No
Yes
No
Yes
Yes
Yes
No
No
No
Yes
Yes
No
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Plain, competible and user
friendly design
t Backlit, long lived silicone keys
t Easy programming
t Internal buzzer
t Chime feature
t Special keys for panic, fire and duress alarm
t Energy saving mode for energy cuttings
t Sabotage switch
t Auto-protection for wrong password entered 5 times
t Ability to read event log
t Automatic key light when a motion detected in a
determined zone
t Ability to reset smoke detector, connected to PGM
outputs, through the keypad
t Lead-free, durable plastic body
18
www.teknim.com | sales@teknim.com
NEW
TLP-NET Network Module
t TPLNET module supplies communication beetwen VAPMAN
alarm management software and VAP series panels via network
and ethernet port.
§ Detailed event log
memory review
§ Monitoring and setting
panel status online
§ Arming/disarming panel,
controlling zones and PGMs
t VAPMAN Alarm Management Software lets users and installers to control and set VAP Series Alarm Panels from a
local/remote PC or internet via serial ports, modem or network...
Be anywhere in the world, security of your property is at your fingertips...
19
Optional Modules
Conventional Fire Alarm Systems
Intruder Alarm Sytems
VAPMAN
Alarm Management Software
Installers;
t Accessing panel from a local/remote PC or internet by using
remote access code and installer code
t Making all installer settings which can be done with keypad.
t Loading saved panel settings in their computer during installation
t Saving settings of the installed panel to their computer, and
when a problem occurs, they can reach necessary information
easily. If necessary, corrupted settings can be re-load
t Solving the panel troubles by remote communication. Saving
customer details (For ex; name, phone, panel type…etc.)
t Downloading event log (event log can be printed out or saved as
.xls file)
Master Users;
t Accessing control panel from a local/remote PC or internet by
using remote access code and master user code
t Making all master user settings (time/date settings, keypad
settings, user authorizations, user codes…etc) which can be done
with keypad
t Controlling the panel (arming/disarming panel, controlling PGMs,
by-passing, testing siren, PGM, user/CMS phones …etc.)
t Monitoring panel status online
t Downloading event log (event log can be printed out or saved as
.xls file)
Users;
t Accessing control panel from a local/remote PC or internet by
using remote access code and user code
t Controlling the panel according to authorization given by master
user (Arming/disarming, controlling PGMs, by-passing, testing siren,
PGM, user/CMS phones …etc.)
t Monitoring panel status online according to authorization given
by master user
t Downloading event log (event log can be printed out or saved as
.xls file)
20
www.teknim.com | sales@teknim.com
Optional Modules
Alarm panel detects events, when users call in during the event by type of
event that transmits voice messages as. Each event is recorded as a factory
for the type of voice recording and can not be changed.
TPL-MDM
Modem Module
TPL-MDM Modem Module supplies communication between all VAP series
alarm panels and remote PC via PSTN port. Users can read, change and
control all panel settings, read event log memory, monitor and control panel
status from a remote PC by using VAPMAN alarm management software
via TPL-MDM Modem Module.
t Standard in VAP 408 and VAP 416 Alarm Panels and adopted with VAP
304, VAP 308 and VAP 404 Alarm Panels
t 5V, 50mA power supplied from alarm panel
Intruder Alarm Sytems
Voice Message Module
Conventional Fire Alarm Systems
VAV-264
t 90 x 50 mm dimensions
VPL-USB
PC Link Module
VPL-USB PC Link Module supplies communication between all VAP series
alarm panels and local PC via USB port. Users can read, change and control
all panel settings, read event log memory, monitor and control panel status
from a local PC by using VAPMAN alarm management software via VPLUSB PC Link Module.
t Adopted with all VAP series alarm panels
t 5V, 20mA power supplied from alarm panel
t 90 x 50 mm dimensions
VAV-210
Voice Recording Module
VAV-210 Voice Recording Module supplies to send recorded alarm message
to the users during alarm instead of alarm warning signal. User can record an
alarm message up to 20 sec by using microphone on the module. Since the
message is recorded in the flash memory on the module, the recorded
message is not deleted during power cut.
t 20 sec. voice recording
t Adopted with all VAP series alarm panels
t 5V, 20mA power supplied from alarm panel
t 90 x 50 mm dimensions
www.teknim.com | sales@teknim.com
21
Optional Modules
Conventional Fire Alarm Systems
Intruder Alarm Sytems
TRM-904
PGM Relay Output Module
TRM-904 PGM Relay Output Module supplies total 4 PGM Relay output for
VAP 404, VAP 408 and VAP 416 alarm panels. This module ensures the
same PGM features supplied by adopted alarm panels.
t Adopted with VAP-404, VAP-408 and VAP-416 alarm panels
t Using max. 2 modules in a panel and by this way; increasing total PGM
output amount to 8
t 240V, 7A NC/NO relay contacts
t 5V, 150mA power supplied from alarm panel
t 90 x 50 mm dimensions
VAG-204
4 Zones Expansion Module
VAG-204 4 zones Expansion Module supplies 4 additional zones to VAP
series alarm panels. This module ensures the same zone features supplied
by any VAP series alarm panel.
t Adopted with VAP-404, VAP-408 and VAP-416 alarm panels
t Using max. 2 modules in a panel and by this way; increasing total PGM
output amount to 8
t 240V, 7A NC/NO relay contacts
t 5V, 150mA power supplied from alarm panel
t 90 x 50 mm dimensions
ATR-244
Wireless Receiver Module
Developed for use VAP Series alarm panels with wireless detectors and
keyfob remote controllers. Total 7 wireless devices are supported.
t High reception sensitivity antenna
t 433.92 MHz working frequency
t Easy learn/erase operation
t No external power required
t Dimensions: 90x50mm
ARC-844
Remote Control
t Aesthetic design with 4 buttons (Arm home, arm away, disarm, panic)
t 128 bit encrypted rolling code system
t Customizable panic button
t 433.92 MHz working frequency
t Long life 12V, 27A type alkaline battery
22
www.teknim.com | sales@teknim.com
PIR Detectors
ATP-570
Dual Technology Motion Detector
t Fully digital
110
Top view
0
t Antimasking
t And/or selection for alarm output
t High RF immunity
t Pulse count
0.3]
R34[1
R60[15.0]
R10[2.9]
R16[4.9]
t Suitable for ceiling, wall and corner fitting
Side view
t Tamper alarm output
t Strong mounting foot
10[2.9]
16[4.9]
t 3 color indicator
34[10.3]
Intruder Alarm Sytems
t Separate adjustable sensitivity for microwave and PIR
60[15.0]
Technical Specifications
Dual element, digital
10.525GHz
9-16VDC, 50mA@12V
15m@110°
NC 30VDC, 0.2A max
NC (cover open activated)
Red, yellow and green (can be disabled)
Average 20V/m (10 MHz - 2 GHz.)
0,3 1.5 m/sec.
2.1m
%95 RH (maximum)
-20C 60C (-4F 140F)
108 x 63 x 50 mm
Conventional Fire Alarm Systems
Infrared sensor
Microwave sensor
Power requirement
Detection range
Alarm output
Tamper switch
Activation LED
RFI Immunity
Detectable speed
Mounting height
Humidity
Temperature
Dimensions (W X H X D)
ATP-540 SERIES PIR DETECTORS
Quality is in details...
t
Lead-free plastic material
Sensitivity adjustment by trimpot; you are not limited to choose only high or low
sensitivity range, also any desired sensitivity ranges can be choosen
t
Solid-state relay module; no moving parts inside so that has excellent advantages,
such as; unlimited operating life, consumes lower current, no possibility of tricking
with external factors such as magnet
t
As a result of very careful and hard R&D works; has excellent reliable software
which prevents false alarm, protect sensitivity perfectly
t
t
German-made digital sensor
Electronic board; manufactured with SMD technology, gold-plated, lead-free,
double-layered
t
Lens; HDPE material, with UV filtration, secured by a patent, USA-made, with
14m@110° detection range
t
t
1/2/3 selectable pulse count
www.teknim.com | sales@teknim.com
23
PIR Detectors
ATP-540LR
Long Range Digital PIR Detector
Intruder Alarm Sytems
t Digital signal processing by microcontroller
t 20m long range
t Dual element digital sensor
75
t Ultra sensitive with 14 bit resulation
0
Top View
t Smart algoritm against false alarm
t Sensitivity adjustment by trimpot
t Pulse count options (1/2/3)
R1
.0]
3[4
t Suitable for ceiling, wall and corner fitting
t Cable canals at back side
.0]
3[7
R2
.2]
[20
R40
R8[2.4]
Side View
t Tamper alarm output
8[2.4]
Conventional Fire Alarm Systems
t Strong mounting foot
13[4.0]
23[7.0]
40[20.2]
Technical Specifications
Infrared sensor
Power requirement
Current drain
Detection range
Alarm output
Pulse count
Sensitivity adjustment
Tamper switch
Activation LED
RFI Immunity
Detectable speed
Mounting height
Humidity
Temperature
Dimensions (W X H X D)
ATP-540N
Dual element, digital
9-16VDC, 12V
20mA, 12VDC
20m@75°
NC 30VDC, 0.2A max
1/2/3 selectable
By trimpot
NC (cover open and wall removel activated)
Red (can be disabled)
Average 20V/m (10 MHz - 2 GHz.)
0,3 1.5 m/sec.
2.1m
%95 RH (maximum)
-20C 60C (-4F 140F)
108 x 63 x 50 mm
Digital PIR Detector
t Dual element digital sensor
t Ultra sensitive with 14 bit resulation
Top View
110
0
t Digital signal processing by microcontroller
t Smart algoritm against false alarm
t Sensitivity adjustment by trimpot
t Suitable for ceiling, wall and corner fitting
t Cable canals at back side
1.7]
R38[1
R46[14]
R11[3.3]
R18[5.6]
Side View
t Tamper alarm output
t Strong mounting foot
11[3.3]
18[5.6]
38[11.7]
46[14.0]
Technical Specifications
Infrared sensor
Power requirement
Current drain
Detection range
Alarm output
Pulse count
Sensitivity adjustment
Tamper switch
Activation LED
RFI Immunity
Detectable speed
Mounting height
Humidity
Temperature
Dimensions (W X H X D)
24
Dual element, digital
9-16VDC, 12V
20mA, 12VDC
14m@110°
NC 30VDC, 0.2A max
1/2/3 selectable
By trimpot
NC (cover open and wall removel activated)
Red (can be disabled)
Average 20V/m (10 MHz - 2 GHz.)
0,3 1.5 m/sec.
2.1m
%95 RH (maximum)
-20C 60C (-4F 140F)
108 x 63 x 50 mm
www.teknim.com | sales@teknim.com
PIR Detectors
ATP-540P
Pet Immune Digital PIR Detector
t Ultra sensitive
Top View
t High false alarm sensibility
90
0
t Selectable pulse counts
t Using without mounting foot because of pet
immunity feature Suitable for ceiling, wall and
corner fitting
t Cable canals at back side
t Tamper alarm output
t Walking test
R1
.0]
3[4
.0]
3[7
R2
.2]
[10
R40
R8[2.4]
Side View
8[2.4]
13[4.0]
23[7.0]
40[10.2]
Technical Specifications
Infrared sensor
Power requirement
Pet Immunity
Current drain
Detection range
Alarm output
Pulse count
Sensitivity adjustment
Tamper switch
Activation LED
RFI Immunity
Detectable speed
Mounting height
Humidity
Temperature
Dimensions (W X H X D)
ATP-105
Dual element, digital
9-16VDC, 12V
Up to 18kg and 60cm
20mA, 12VDC
10m@90°
NC 30VDC, 0.2A max
1/2/3 selectable
By trimpot
NC (cover open and wall removel activated)
Red (can be disabled)
Average 20V/m (10 MHz - 2 GHz.)
0,3 1.5 m/sec.
2.1m
%95 RH (maximum)
-20C 60C (-4F 140F)
108 x 63 x 50 mm
Conventional Fire Alarm Systems
t Digital technology
Intruder Alarm Sytems
t Temperature compansated
Mounting Foot for ATP Series
PIR Detectors
t This strong mounting foot can be adopted all ATP Series PIR Detectors
t It is designed to supply wall, corner and ceiling mounting options for
installers
t 45° left/right, 15° downward adjustment possible with 5° steps
www.teknim.com | sales@teknim.com
25
Smoke Detectors
TFD-1450
Optical Smoke + Heat
Intruder Alarm Sytems
Multisensor Detector
TFD-1450, is an Optical Smoke + Heat Multisensor were
designed with precise CPU control and thermister detection. It is
state of the art combination of 'Optical Smoke' and 'Fixed
Temperature' ensures the best quality of heat detection in all
environment. Detectors were engineered to the best quality and
durability. They work perfectly with all intruder alarm control
panels.
t 4 wire model, NC relay output
t Adaptive threshold algorithm, to prevent dust caused alarms
Conventional Fire Alarm Systems
t Durable sensor head, no need for replacement
t Inludes microprocessor: High electromagnetic immunity, no
false alarm, immune to all kinds of light source (Etc: Fluorescent
labms)
t Plastic, white housing high temperature endurable and fireproof polymeric material
t Alarm indicator LED can be seen from all points of view (360°,
continuosly emitting red light
t Easy installation and maintenance
t Sleek low-profile housing design
t High quality and reliability guarenteed
t Designed to comply with European and US standarts
t Base Included
TFD-1430
Technical Specifications
Wire
Operation voltage
Alarm current
Standby current
Operation temperature
Alarm temperature
Relative humidity
Installation method
Dimensions
Casing material
Weight (base included)
4 wire NC relay output
12VDC
35mA
100µA max
-10°C to 50°C
54°C
0% to 95%, no condensation or icing
Ceiling mounted
ø110, H:50mm
Plastic, white
0,110kg
Optical Smoke Detector
TFD-1430, is an Optical Smoke Detector provides reliable early
warning of intense fires with fast response by detection smoke
particles. It has the function of dustproof, mothproof, and antielectromagnetic interference. It performs well in detecting visible
smoke caused by hidden or bright fire. It is suitable for detecting
smoke in houses, stores, hotels and warehouses, etc. Detectors
were engineered to the best quality and durability. They work
perfectly with all intruder alarm control panels.
t 4 wire model, NC relay output
t Adaptive threshold algorithm, to prevent dust caused alarms
t Durable sensor head, no need for replacement
t Inludes microprocessor: High electromagnetic immunity, no
false alarm, immune to all kinds of light source (Etc: Fluorescent
labms)
t Plastic, white housing high temperature endurable and fireproof polymeric material
t Alarm indicator LED can be seen from all points of view
(360°, continuosly emitting red light
t Easy installation and maintenance
t Sleek low-profile housing design
t High quality and reliability guarenteed
t Designed to comply with European and US standarts
t Base Included
26
Technical Specifications
Wire
Operation voltage
Alarm current
Standby current
Operation temperature
Detection range
Relative humidity
Installation method
Dimensions
Casing material
Weight (base included)
www.teknim.com | sales@teknim.com
4 wire NC relay output
12VDC
60mA
100µA max
-10°C to 50°C
2
60m @4m height
0% to 95%, no condensation or icing
Ceiling mounted
ø110, H:50mm
Plastic, white
0,110kg
Defeat the insidious enemies with
Teknim TGD Series Gas Detectors...
Every winter, hundreds of citizens get sick or die in our country, because of natural gas and carbonmonoxide
poisoning. It is easier to take precautions instead of risking your life. Nothing is more valuable than your and your
beloved one's lives...
TGD-904
Carbonmonoxide Detector
t Microprocessor design
t Relay output
t Highly stable detection feature
t 8-24V DC
t Automatic reset after alarm
t Recommended for ceiling mounting
t Internal 70dB siren
t LED can be seen from all points of
t Relay output
view (360)°
TGD-903
Conventional Fire Alarm Systems
Intruder Alarm Sytems
Gas Detectors
Natural Gas Detector
t Microprocessor design
t Relay output
t Highly stable detection feature
t 8-24V DC
t Automatic reset after alarm
t Recommended for ceiling mounting
t Internal 70dB siren
t LED can be seen from all points of
t Relay output
view (360)°
27
NEW
ATS-3232 Universal Adjustable Temperature Detector
ATS series adjustable temperature detector is developed to
warn/alarm if the measured temperature goes beyond
determined limits and/or communicate with central monitoring
station. It is compatible with all VAP series and other companies'
alarm panels.
Has 3 different modes;
- When temperature goes over the determined value,
- When temperature goes below the determined value,
- When temperature goes beyond the upper an lower values.
4 Adjustable limit temperature range -32°C~ +32°C (with 1°C
increments)
4 Three different working modes; over limit, under limit, outwindow mode (window can be adjusted ±1°C ~ ±8°C)
4 Ultra sensitive digital temperature sensor
4 Compatible with all VAP series and other brands' alarm panels
4 RS232 port to integrated automation systems
4 Activation LED
4 Strong body
4 Solid state relay
4 All settings can be done by DIP switches
Technical Specifications
Adjustable temperature limit
Temperature tolerance
Power supply
Humidity
Dimensions
-32°C ~ +32°C
Adjustable between ±1°C ~ ±8°C
9-16VDC
95% maximum
108x63x50mm
Suitable to use in places that temperature value must stay between some specific limits for ex: cold stores,
biochemistry laboratories, meat packing houses, food and beverage storages of markets...etc.
28
NEW
TVSD-143 Tilt-Shock-Vibration(Seismic) Detector
A unique product by pioneer of innovations, Teknim:
Selectable 3 functions: Tilt, Shock, Vibration (Seismic):
Tilt, Shock, Vibration (Seismic) Detector has 3 functions as given in its name: Tilt, shock and vibration (seismic).
Either you can active one of these three functions, or you can active all three at the same time. Depending on
where you want to use, it is up to you to choose. Vibration function can be used as a "Seismic Sensor" which
provides warning when an earthquake occurs. You can adjust the sensitivities of Shock and Vibration funtions,
based on where you want to use, that prevents unnecessary alarm situations.
4Shock: The alarm output is activated if the object is exposed to sudden
impacts. With sensitivity adjustment, the alarm output is not activated if the
intensity of the impact stays under the value, that specified by the user.
44Tilt: If the detector inclines more than 15° from its starting position (the position of the detector while switching "on")
to any other positions, the alarm output is activated, until the position of the object is reverted to the starting position.
Selectable 3 functions: Tilt, Shock, Vibration
ology
15° 15°
ALARM
ALARM
ic G
n
Electro
echn
t
r
o
s
n
se
ent
m
t
s
dju
ut
ty a
ivi
sit
Sen
tp
u
yo
ela
r
NC
15° 15°
ALARM
ALARM
"Displacement-Time"
graph of the periodic
oscillatory motion
444Vibration (Seismic): If the detector is exposed to a periodic or
random oscillatory motion caused by an earthquake or a drill, the alarm
output is activated, until the motion stops. Vibrational motion can be in
all three axes (Seperately or combined).
Technical Specifications
Voltage
Contacts
Activation LED
Output relay
Acceleration sensitivity
Working temperature
Sampling time
8-15VDC, 50mA
NC
Red
30VDC, 100mA
0,625mg
0°C - 65°C
1000Hz
29
Conventional Fire Alarm Systems
Intruder Alarm Sytems
Outdoor Sirens
Now, with metal or plastic internal cover options!
VAS-740A / VAS-740A P
Outdoor Siren
t Walking LEDs with 6 super bright LEDs
t Intelligent trigger system that no jumper setting
t Internal or external power supply option during alarm
t Intelligent tamper detection system on power line
t Strong ABS housing with 3 mm thickness
t Internal metal or plastic (optional) protection covers
electronic circuit and components
t Microprocessor controlled
t Tamper protection for removal of the top cover from the
body of the siren or removal of the siren from the wall
t Strong LED strobe
t Two different siren pattern
t Automatic cut off with two option (3 or 10 min)
t Internal rechargeble battery
t Two different siren tone
t Wide and smooth area for company logo
t Easy mounting
Technical Specifications
Power requirement
Frequency
Sound level@1m
Internal battery
Current at EXT mode
Current at INT mode
Stand by current
Dimensios (WxHxD)
Weight
30
9-14VDC, Nominal 12VDC
1400-3000Hz
118dB max.
6V, 330mAh
300mA with flasher@12V
25mA@12V
25mA
215x300x60mm
1,354kg
www.teknim.com | sales@teknim.com
Outdoor & Indoor Sirens
t Strong ABS housing with 3 mm thickness
t Internal metal or plastic (optional) protection covers
electronic circuit and components
t Microprocessor controlled
t High sound level with piezo
t Tamper protection for removal of the top cover from the
body of the siren or removal of the siren from the wall
t Strong strobe, sliding 2 leds
t Auto-tamper
t Automatic inactivation option of the siren
t Internal rechargeable battery
t Two different siren speeds
t Suitable for both positive or negative trigger
t Power voltage from battery or panel during alarm (SAB or
SCB)
t Negative tamper option
t Wide and smooth area for company logo, easy mounting
Technical Specifications
Power requirement
Frequency
Sound level@1m
Internal battery
Current at SAB mode (@12V)
Current at SCB mode (@12V)
Strobe current (@12V)
Stand by current (@12V)
Strobe frequency (@12V)
Dimensios (WxHxD)
Weight
9-14VDC, Nominal 12VDC
1400-3000Hz
118dB max.
6V, 330mAh
200mA
25mA
100mA
10mA
1,0Hz
215x300x60mm
1,354kg
Conventional Fire Alarm Systems
Outdoor Siren
Intruder Alarm Sytems
VAS-720WR, VAS-720WB /
VAS-720WR P, VAS-720WB P
VAS-112B Outdoor Siren with Strobe
t Strong ABS housing with 3 mm thickness
t Supply voltage 8-16V DC (Nominal 12V)
t Alarm current: 25mA@12V
t Operational temperature range: -20°C - 70°C
t Dimensions: Ø:110mm, h:50mm
t Weight: 107g
t Compatible with intruder alarm panels
t 100dB sound level @1m distance (12V DC)
t Blue-white, fire-proof ABS housing
t Strobe: 6 super bright LEDs
www.teknim.com | sales@teknim.com
31
Continuous Power Supplies
Conventional Fire Alarm Systems
Intruder Alarm Sytems
TPS-1201
12V Continuous Power Supply
t 12V DC, 1A , switching (SMPS)
t Used for Intruder Alarm Systems when additional power needed
t Current limited battery charger
t Short circuit protection, automatic resetable fuse
t Dry contact relay for trouble condition
t Dimensions: 30cm(H) x 21cm(W) x 8cm(D)
t 230V, 25VA power input
TPS-1202
12V Continuous Power Supply
t 12V DC, 2A , switching (SMPS)
t Used for Intruder Alarm Systems when additional power needed
t Current limited battery charger
t Short circuit protection, automatic resetable fuse
t Dry contact relay for trouble condition
t Dimensions: 30cm(H) x 21cm(W) x 8cm(D)
t 230V, 35VA power input
TPS-2401
24V Continuous Power Supply
t 24V DC, 1A , switching (SMPS)
t Used for Fire Alarm Systems when additional power needed
t Current limited battery charger
t Short circuit protection, automatic resetable fuse
t Dry contact relay for trouble condition
t Dimensions: 30cm(H) x 30cm(W) x 8cm(D)
t 230V, 25VA power input
TPS-2402
24V Continuous Power Supply
t 24V DC, 2A , switching (SMPS)
t Used for Fire Alarm Systems when additional power needed
t Current limited battery charger
t Short circuit protection, automatic resetable fuse
t Dry contact relay for trouble condition
t Dimensions: 30cm(H) x 30cm(W) x 8cm(D)
t 230V, 35VA power input
32
www.teknim.com | sales@teknim.com
Can you risk your life, instead of
taking the simplest precautions?
CONVENTIONAL FIRE ALARM SYSTEMS
Fire Alarm Panels
TFP-908 / 916 / 924 / 932
Expandable
Intruder Alarm Sytems
Conventional Fire Alarm Panels
Technical Specifications
Zone number
Number of detectors for each
zone to be connected
End of line resistor
Power supply
Power output
Siren output
Fire relay
Conventional Fire Alarm Systems
Trouble relay
Battery
Humidity
Temperature
Dimensions
Weight
LCD
8 / 16 / 24 / 32
30 (Teknim TF Series)
6,8kΩ
230V, 35VA with internal transformer
6-25VDC, 1A with automatic fuse
24VDC, 0,5A with automatic fuse, 6,8kΩ end
of line resistor
30V 1A NC/NO dry contact, customizable
according to alarm type
30V 1A NC/NO dry contact, customizable
according to trouble type
2 pcs 12V 7Ah
95% RH (maximum)
-10°C ~ 55°C (14°F ~ 131°F)
370x310x100mm
4kg
x2
x100
PREALARM
BYPASS
t 24V, from 8 zone to 32 zone. Each type can expand
up to 32 zones
t Easy to use with large graphic LCD
t Seperate status, alarm and trouble LEDs
t Zone names can be entered
t 100 pcs. event memory with date and time
information
t Night mode (automatic or manual)
t Pre-alarm capability (can be set for each zone, can
be cancelled from front panel)
t Smart battery charger, long battery life (Able to see
battery voltage on display)
t Serial port for control by PC or to integrate with an
automation system. Commands like “AT”
t Plug & Play expansion modules, no programming
necessary
t EOL supervised siren output and zone inputs
t Zone type can be selectable as button or detector
t Zone test feature
TFX-108
t 6-25V adjustable 1A power output with automatic fuse
t 1 pc. NC/NO customizable fire relay (Button alarm, detector
alarm etc.)
t 1pc.NC/NO customizable error relay (Mains failure zone,
battery trouble etc)
t Bypass feature, “BYPASS” led on the front panel, bypassed
zones can be seen on LCD
t Key system to determine authorization level, warning
messages on screen when key needed
t Easy to understand front panel, menu system for
easyprogramming
t Support for multi language
t Switched power supply
t Metal box
t Ready places in box for expand modules
t Compact, small dimensions
t Used with 2 pcs of 12V 7Ah battery
t Designed to comply with European and US standarts
8 Zones Expansion Board for
TFP-900 Series
t 8 zones with end of line resistor
t Having charged from panel, no need extra power supply
34
www.teknim.com | sales@teknim.com
Fire Alarm Panels
Conventional Fire Alarm Panel
t 24V, 8 zones
t 1 pc NC/NO fire relay
t Separate fire and trouble
t 1 pc NC/NO trouble relay
LEDs for each zone
t EOL supervisory for zone
inputs and siren output
t Zone test feature
t 24V 0,5A AUX power output
with automatic fuse protected
t 0,5A automatic fuse protected
siren output
t Bypass feature
t Key protected front panel
buttons against unwanted
interference
t Easy to understand front panel
t Metal box
t Designed to comply with
European and US standarts
Intruder Alarm Sytems
TFP-808
Fire relay
Trouble relay
Dimensions (WxHxD)
Weight
x2
8
6,8kΩ
230V, 35VA
24VDC, 0,5A with automatic fuse
24VDC, 0,5A with automatic fuse, 6,8kΩ
EOL supervised
30V 1A NC/NO dry contact
30V 1A NC/NO dry contact
370x310x100mm
4kg
BYPASS
www.teknim.com | sales@teknim.com
Conventional Fire Alarm Systems
Technical Specifications
Zone
End of line resistor
Mains input
Aux output
Siren output
35
Fire Alarm Panels
Conventional Fire Alarm Systems
Intruder Alarm Sytems
TFP-802 / 804
Conventional Fire Alarm Panels
t Just 1 pc 12V 7Ah battery
required
t 24V, 2 zones (TFP-802) or 4
zones (TFP-804)
t Each zone has separate fire
and trouble LEDs
t Supervised siren outputs and
zone inputs by end of line
resistor
t Zone test feature
t 12V / 24V selectable,
automatic fuse protected
auxilary power output
t NC/NO fire relay
x1
t Requested zones can be bypassed
t Key lock system against
unwanted intervention
t Easy to understand front panel
t Metal box
t Bypass each zones
t Intelligent battery charging
system to prolong battery life
t Compact design
t Microprocessor
t SMD material technology
t Designed to comply with
European and US standarts
BYPASS
Technical Specifications
Zone
Battery
Number of detectors
End of line resistor
Power supply
Power output
Siren output
Fire relay
Trouble relay
Humidity
Temperature
Dimensions (WxHxD)
Weight
2 (TFP-802) / 4 (TFP-804)
1 pc 12V 7Ah, sealed type, lead acid
Up to 30 pcs for each zone
6,8kΩ
230V, 25VA with internal transformer
250mA internal fuse protection
12/24VDC selectable, automatic fuse,
TFP-802: 500mA 12V or 300mA 24V
TFP-804: 500mA 12V or 500mA 24V
24VDC, 6,8kΩ end of line resistor
30V 1A NC/NO dry contact
30V 1A NC/NO dry contact
95% RH (Max)
-10°C ~ 55°C (14°F ~ 131°F)
210x300x80mm
2,5kg (Without packing and battery)
TFP-800 Series
MODEL
Zone
Battery
End of line resistor
Power supply
Power output
Siren output
Fire relay
Trouble relay
Key lock
Box
Humidity
Temperature
Dimensions (WxHxD)
Weight
36
t NC/NO trouble relay
Conventional Fire Alarm Panels Comparison Table
TFP-802
2
1 pc 12V 7Ah, sealed type, lead acid
6,8kΩ
230V, 25VA
12/24VDC selectable, automatic fuse
12/24VDC selectable, automatic fuse
500mA 12V or 300mA 24V
30V 1A NC/NO dry contact
30V 1A NC/NO dry contact
YES
Metal
95% RH (Max)
-10°C ~ 55°C (14°F ~ 131°F)
210x300x80mm
2,5kg (Without packing and battery)
TFP-804
4
1 pc 12V 7Ah, sealed type, lead acid
6,8kΩ
230V, 25VA
12/24VDC selectable, automatic fuse
12/24VDC selectable, automatic fuse
500mA 12V or 500mA 24V
30V 1A NC/NO dry contact
30V 1A NC/NO dry contact
YES
Metal
95% RH (Max)
-10°C ~ 55°C (14°F ~ 131°F)
210x300x80mm
2,5kg (Without packing and battery)
www.teknim.com | sales@teknim.com
TFP-808
8
2 pc 12V 7Ah, sealed type, lead acid
6,8kΩ
230V, 35VA
12/24VDC selectable, automatic fuse
12/24VDC selectable, automatic fuse
30V 1A NC/NO dry contact
30V 1A NC/NO dry contact
YES
Metal
95% RH (Max)
-10°C ~ 55°C (14°F ~ 131°F)
370x310x100mm
4kg (Without packing and battery)
Fire Alarm Detectors
TFD-1250
Optical Smoke + Heat
Intruder Alarm Sytems
Multisensor Detector
TFD-1250, is an Optical Smoke + Heat Detectors were
designed with precise CPU control and thermister detection. It
is state of the art combination of 'Optical Smoke' and 'Fixed
Temperature' ensures the best quality of heat detection in all
environment. Detectors were engineered to the best quality
and durability. They work perfectly with all conventional fire
control panels.
t 2 wire model
t Advanced detection and discrimination algorithms
t SMD circuit board design-satisfactory quality and reliability
guarenteed
t Plastic, white housing high temperature endurable and fireproof polymeric material
t Alarm indicator LED can be seen from all points of view (360°,
continuosly emitting red light
t Easy installation and maintenance
t Sleek low-profile housing design
t High quality and reliability guarenteed
t Strong body
t Designed to comply with European and US standarts
t Base Included
TFD-1230
Technical Specifications
Wire
Operation voltage
Alarm current
Standby current
Operation temperature
Alarm temperature
Relative humidity
Installation method
Dimensions
Casing material
Weight (base included)
2 wire
20-28VDC
100mA max.
100µA max.
-10°C to 50°C
57°C
0% to 95%, no condensation or icing
Ceiling mounted
ø110, H:50mm
Plastic, white
0,110kg
Conventional Fire Alarm Systems
t Durable sensor head, no need for replacement
Optical Smoke Detector
TFD-1230, is an Optical Smoke Detector provides reliable
early warning of intense fires with fast response by detection
smoke particles. It has the function of dustproof, mothproof,
and anti-electromagnetic interference. It performs well in
detecting visible smoke caused by hidden or bright fire. It is
suitable for detecting smoke in houses, stores, hotels and
warehouses, etc. Detectors were engineered to the best
quality and durability. They work perfectly with all conventional
fire control panels.
t 2 wire model
t Detection of intense fires with fast response under rapid
temperature-rise situation
t SMD circuit board design-satisfactory quality and reliability
guaranteed
t Mechanical moving parts provide stability, durability and
reliability
t Self-restoring bimetal elements allow continual use
t Plastic, white housing high temperature endurable and fireproof polymeric material
t Alarm indicator LED, continuosly emitting red light
t Easy installation and maintenance
t Designed to comply with European and US standarts
t Base Included
Technical Specifications
Wire
Operation voltage
Alarm current
Standby current
Operation temperature
Relative humidity
Installation method
Dimensions
Casing material
Weight (base included)
www.teknim.com | sales@teknim.com
2 wire
20-28VDC
100mA max.
100µA max.
-10°C to 50°C
0% to 95%, no condensation or icing
Ceiling mounted
ø110, H:50mm
Plastic, white
0,110kg
37
Fire Alarm Detectors
TFD-1220
Fixed Temperature +
Conventional Fire Alarm Systems
Intruder Alarm Sytems
Temperature Increase Detector
TFD-1220, is a Fixed Temperature & Temperature Increase
Detector provides reliable early warning of intense fires with fast
response under rapid temperature-rise situation.
Detectors were engineered to the best quality and durability.
They work perfectly with all conventional fire control panels.
t 2 wire model
t Detection of intense fires with fast response under rapid
temperature-rise situation
t SMD circuit board design-satisfactory quality and reliability
guarenteed
t Mechanical moving parts provide stability, durability and
reliability
t Self-restoring bimetal elements allow continual use
t Plastic, white housing high temperature endurable and fireproof polymeric material
t Alarm indicator LED, continuosly emitting red light
t Easy installation and maintenance
t Sleek low-profile housing design
t High quality and reliability guarenteed
t Strong body
t Designed to comply with European and US standarts
t Base Included
TFD-1210
Technical Specifications
Wire
Operation voltage
Alarm current
Standby current
Operation temperature
Alarm temperature
Relative humidity
Installation method
Dimensions
Casing material
Weight (base included)
2 wire
20-28VDC
50mA max.
50µA max.
-10°C to 50°C
57°C
0% to 95%, no condensation or icing
Ceiling mounted
ø110, H:50mm
Plastic, white
0,110kg
Fixed Temperature Detector
TFD-1210, is a Fixed Temperature Detector provides reliable
early warning of a fire condition upon ambient temperature
reaching a fixed temperature threshold. Detectors were
engineered to the best quality and durability. They work perfectly
with all conventional fire control panels.
t 2 wire model
t Detection of intense fires with fast response under rapid
temperature-rise situation
t SMD circuit board design-satisfactory quality and reliability
guaranteed
t Mechanical moving parts provide stability, durability and
reliability
t Self-restoring bimetal elements allow continual use
t Plastic, white housing high temperature endurable and fireproof polymeric material
t Alarm indicator LED, continuosly emitting red light
t Easy installation and maintenance
t Sleek low-profile housing design
t High quality and reliability guarenteed
t Strong body
t Designed to comply with European and US standarts
t Base Included
38
Technical Specifications
Wire
Operation voltage
Alarm current
Standby current
Operation temperature
Alarm temperature
Relative humidity
Installation method
Dimensions
Casing material
Weight (base included)
www.teknim.com | sales@teknim.com
2 wire
20-28VDC
50mA max.
50µA max.
-10°C to 50°C
57°C
0% to 95%, no condensation or icing
Ceiling mounted
ø110, H:50mm
Plastic, white
0,110kg
Indoor Fire Sirens & Strobes
TFS-202 is used to produce signalization up on detected fire
condition. It is highly preferred for internal usage because of its
aesthetics design and easy to use. The sounder provides sounds
level 85dB.
Technical Specifications
Supply voltage
Current consumption in duty mode
Current consumption in activated sounder
Sound level at 1m distance
Operational temperature range
Relative humidity resistance
Dimensions (WxHxD)
Weight (base included)
Cross section of the connecting wire
Degree of protection
TFS-201
20-28VDC
500µA
22mA@24V
100dB
-10°C to 55°C
(93±3) at 40°C
130x110x40mm
0,267kg
(0,8-2,5)mm2
IP30
Indoor Fire Siren
TFS-201 is designed to produce signalization up on detected fire
condition. It is highly preferred for internal usage because of its
aesthetics design and easy to use. The sounder provides sounds
level 85dB.
Intruder Alarm Sytems
Indoor Fire Siren (with strobe)
Conventional Fire Alarm Systems
TFS-202
Technical Specifications
Supply voltage
Current consumption in duty mode
Current consumption in activated sounder
Sound level at 1m distance
Operational temperature range
Relative humidity resistance
Dimensions (WxHxD)
Weight (base included)
Cross section of the connecting wire
Degree of protection
TFS-203
20-28VDC
500µA
18mA@24V
100dB
-10°C to 55°C
(93±3) at 40°C
130x110x40mm
0,267kg
(0,8-2,5)mm2
IP30
Indoor Fire Strobe
TFS-203 is used to produce silent but visual signalization up on
detected fire condition. It is highly preferred for internal usage
because of its aesthetics design and easy to use.
www.teknim.com | sales@teknim.com
39
Outdoor Fire Sirens & Gas Detectors
VAS-740 F
Outdoor Fire Siren
Intruder Alarm Sytems
t 2 wires
t 6 super bright LEDs
t 115dB sound level (@24V DC, from 1m distance)
t Frequency: 500-1400Hz
t 100mA@24V operating current
t 20-28V DC
t Operating temperature: -20°C - 70°C arası
t Dimensions: 215x300x60mm
Conventional Fire Alarm Systems
t UL 94 fireproof red ABS body
TGD-904F Carbonmonoxide Detector
for Conventional Fire Alarm Panels
t Microprocessor design
t Highly stable detection feature
t Automatic reset after alarm
t Internal 70dB siren
t Relay output
t Relay output
t 8-24V DC
t Recommended for ceiling mounting
t LED can be seen from all points of view (360)°
TGD-903F Natural Gas Detector
for Conventional Fire Alarm Panels
t Microprocessor design
t Highly stable detection feature
t Automatic reset after alarm
t Internal 70dB siren
t Relay output
t Relay output
t 8-24V DC
t Recommended for ceiling mounting
t LED can be seen from all points of view (360)°
40
www.teknim.com | sales@teknim.com
Security is not the one and only thing we care about...
All Teknim products are produced with eco-friendly production techniques.
All TEKNİM products comply with the RoHs directive 2002/95/EC, restricts the
use of toxic substances (such as lead, mercury, cadmium, hexavalent chrome,
polybrominated biphenyls, polybrominated diphenyl ethers) widely used in
electronics. (For more information www.rohs.eu )
We care about the health of yours and your beloved ones.
We care about the earth that we live on.
Dudullu Organize Sanayi Bolgesi 1. Cadde Ismet Tarman Is Merkezi
Bina No:1 Kat:2 No:24 PK:34776 Umraniye/ ISTANBUL
Telephone: +902164990680(pbx) Fax: +902164990679
sales@teknim.com
www.teknim.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising