Rheem Prestige® Series Communicating Two Stage Variable

Rheem Prestige® Series Communicating Two Stage Variable
Air
Gas Furnaces
R96V Series
Rheem Prestige® Series Communicating
Two Stage Variable Speed Multi position
Gas Furnaces
R96V- Series
96% A.F.U.E.†
Input Rates from 40 to 115 kBTU
[11.72 to 33.71 kW]
All Models
except
R96VA085
✝ A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with
Department of Energy test procedures.
• 96% residential gas furnace CSA certified
• 4 way multi-poise design
• Two stages of operation to save energy and maintain optimal
comfort level.
• Variable speed blower motor technology provides ultimate
humidity control, quieter sound levels, and year round energy
savings.
• EcoNet™ enabled HVAC Product
• PlusOne™ Diagnostics 7-Segment LED all units
• PlusOne™ Ignition System – DSI for reliability and longevity
• PlusOne™ Water Management System with patented Blocked
Drain Sensor
• Heat exchanger is removable for improved serviceability.
Aluminized steel primary and stainless steel secondary construction provide maximum corrosion resistance and thermal
fatigue reliability.
• Low profile “34 inch” cabinet ideal for space constrained
installations.
• Blower Shelf design – serviceable in all furnace orientations
• Pre marked hoses – insures proper system drainage
• Vent with 2" or 3" PVC
• Replaceable Collector box
• Hemmed edges on cabinet and doors
• Quarter turn fasteners for tool less access
• Integrated control boards feature dip switches for easy
system set up
• Self priming condensate trap
• Solid bottom included
• Compatible with single or two stage thermostats. For optimal
performance a two stage thermostat is recommended.
FORM NO. G11-540 REV. 6
Air
Table of Contents
R96V Series
TABLE OF CONTENTS
Standard & Optional Equipment ......................................................................3
Physical Data & Specifications ........................................................................4
Model Number Identification ............................................................................5
Dimensional Data............................................................................................6
Blower Performance Data ................................................................................7
Accessories....................................................................................................8
Limited Warranty ............................................................................................9
2
Air
Standard & Optional Equipment
R96V Series
REMOTE
SENSOR
DIRECT SPARK IGNITION &
REMOTE SENSOR
PRIMARY AND SECONDARY
HEAT EXCHANGER
GAS VALVE AND MANIFOLD
IN-SHOT BURNERS
DRAFT
INDUCER
PRESSURE SWITCHES
BLOCKED DRAIN
SENSOR
ECM MOTOR
CONTROL BOARD
STANDARD EQUIPMENT
OPTIONAL EQUIPMENT
Completely assembled and wired; blocked drain sensor, 7
segment LED and marked hoses; heat exchanger; primary:
aluminized steel, secondary: 29-4C stainless steel; 2 stage
induced draft; pressure switches; redundant 2 stage main gas
control; blower compartment door safety switch; solid state
time on/off blower control; limit controls; manual shut-off
valve; 100% safety lock out; cool fan off delay; field selectable
heat fan off delay; one hour automatic retry; power and selftest diagnostics; flame sense current diagnostics; electronic
air cleaner connections; humidifier connections; humidifier
on/off delay; low speed continuous fan option; single speed
option for heating and cooling applications; transformer; direct
drive, variable speed electrically commutated blower motor
(ECM). Solid bottom. (Please note: a thermostat is not
included as standard equipment.)
Side and bottom filter racks; return air cabinet for all sizes.
NOTE: Furnace is not listed for use with fuels other than natural
or L.P. (propane) gas.
All models can be converted by a qualified distributor or local
service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from
natural to L.P. (propane) gas and may be ordered as optional
accessories from a parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
3
Air
Physical Data & Specifications
R96V Series
Physical Data and Specifications—Upflow Models
U.S. and Canadian Models
MODEL NUMBERS
R96VA0402317MSA R96VA0602317MSA R96VA0702317MSA R96VA0852521MSB R96VA1002521MSA R96VA1152524MSA
HIGH FIRE INPUT BTU/HR [kW] ➀
LOW FIRE INPUT
HEATING CAPACITY BTU/HR [kW]
HIGH ALTITUDE OUTPUT
10% DERATE [kW] ➁
BLOWER (D x W)
[mm]
MOTOR H.P. [W]–
TYPE
MIN. CIRCUIT AMPACITY
MIN. OVERLOAD PROTECTION DEVICE
MAX. OVERLOAD PROTECTION DEVICE
MINIMUM EXT. STATIC PRESSURE
(IN. W.C.) [kPa]
MAXIMUM EXT. STATIC PRESSURE
(IN. W.C.) [kPa]
HEATING CFM @ .2" [.049 kPa]
W.C. E.S.P. [L/s]
COOLING CFM @ .5" [.124 kPa]
W.C. E.S.P. [L/s]
TEMPERATURE RISE-HIGH FIRE
RANGE IN DEGREES °F [°C]
TEMPERATURE RISE-LOW FIRE
RANGE IN DEGREES °F [°C]
APPROX. SHIPPING WEIGHT
(LBS.) [kg]
AFUE ➂
42,000 [12.31]
29,400 [8.61]
41,000 [12.02]
56,000 [16.41]
39,200 [11.49]
55,000 [16.12]
70,000 [20.50]
49,000 [14.36]
68,000 [19.93]
84,000 [24.61]
58,800 [17.23]
82,000 [24.03]
98,000 [28.72]
68,600 [20.11]
95,000 [27.84]
112,000 [32.82]
78,400 [23.00]
109,000 [31.94]
36,288 [10.64]
48,384 [14.18]
60,480 [17.72]
72,756 [21.27]
84,672 [24.81]
96,768 [28.36]
11 x 7
[279 x 178]
11 x 8
[279 x 203]
11 x 8
[279 x 203]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
11 x 11
[279 x 279]
1/2 [373] E.C.M.
1/2 [373] E.C.M.
1/2 [373] E.C.M.
3/4 [559] E.C.M.
3/4 [559] E.C.M.
3/4 [559] E.C.M.
8.00
15.00
15.00
7.00
15.00
15.00
9.00
15.00
15.00
12.00
15.00
20.00
12.00
15.00
20.00
12.00
15.00
15.00
.18 [.045]
.20 [.050]
.23 [.057]
.28 [.070]
.28 [.070]
.28 [.070]
1.0 [0.249]
1.0 [0.249]
1.0 [0.249]
1.0 [0.249]
1.0 [0.249]
1.0 [0.249]
1050 [496]
1025 [484]
1015 [479]
1470 [694]
1710 [807]
1450 [684]
1050 [496]
1050 [496]
1050 [496]
1750 [826]
1750 [826]
1750 [826]
20 - 50
[11 - 28]
15 - 45
[8 - 25]
30 - 60
[17 - 33]
20 - 50
[11 - 28]
40 - 70
[22 - 39]
30 - 60
[17 - 33]
30 - 60
[17 - 33]
20 - 50
[11 - 28]
40 - 70
[22 - 39]
30 - 60
[17 - 33]
45 - 75
[25 - 42]
35 - 63
[19 - 36]
128 [58]
128 [58]
132 [60]
147.5 [67]
152 [69]
165 [75]
96.00%
96.00%
96.00%
96.00%
96.00%
96.00%
NOTES: All models are 115V, 60HZ, 1 phase Gas connection size for all models is 1/2" [13 mm] N.P.T.
➀ Installation instructions for high altitude derate.
➁ Canadian installations only.
➂ In accordance with D.O.E. test procedures.
*S=Standard Models
NOTE: Standard model complies with California low nox requirements.
[
] Designates Metric Conversions
4
Air
Model Number Identification
R96V Series
Model Number Identification
R
96
Rheem
96%
Efficient
[
V
A
Motor - Design Series
ECM A = 1st Design
—
040
2
Input
BTU/HR
040 = 42,000 [12.31 kW]
060 = 56,000 [16.41 kW]
070 = 70,000 [20.51 kW]
085 = 84,000 [24.62 kW]
100 = 98,000 [28.72 kW]
115 = 112,000 [32.82 kW]
Stage - Two
3
17
M
S
A
Airflow
Cabinet Width Configuration - S = Standard
Revision 3 - Up to 3 Tons
17 = 17.5"
Multi-Position
Marketing
5 - Up to 5 Tons
21 = 21.0"
(A - First Time
24 = 24.5"
Release)
(B - First
Revision)
] Designates Metric Conversions
5
Air
Dimensional Data
R96V Series
UNIT DIMENSIONS
(CLEARANCE TO COMBUSTIBLES)
MODEL
R96V
LEFT
SIDE
040
060
070
085
100
115
0
0
0
0
0
0
MINIMUM CLEARANCE (IN.) [mm]
RIGHT
SIDE
BACK
TOP
FRONT
VENT
0
0
0
0
0
0
0
0
0
0
0
0
1 [25]
1 [25]
1 [25]
1 [25]
1 [25]
1 [25]
2 [51]
2 [51]
2 [51]
2 [51]
2 [51]
2 [51]
0
0
0
0
0
0
*A service clearance of at least 24" is recommended in front of all furnaces
Supply and return depicted as upflow configuration.
Flange configuration will vary depending on installation orientation.
6
FLANGE DIMENSIONS
SHIP
WGTS.
A
B
C
123.5 [56]
171/2 [445]
1617/64 [413]
1613/64 [412]
128
[58]
171/2
[445]
1617/64
[413]
1613/64 [412]
[60]
171/2
[445]
1617/64
[413]
1613/64 [412]
[533]
1949/64
[502]
1945/64 [500]
[533]
1949/64
[502]
1945/64 [500]
[662]
2317/64
[591]
2313/64 [589]
132
147.5 [67]
152
165
[69]
[75]
21
21
241/2
[
] Designates Metric Conversions
Air
MODEL NUMBER
TARGET
GAS
HEATING
AIRFLOW
TARGET
COOLING/
HEAT-PUMP
AIRFLOW
Blower Performance Data
R96V Series
R96VA0402317MSA R96VA0602317MSA R96VA0702317MSA R96VA0852521MSB R96VA1002521MSA R96VA115524MSA
SW 15 = SW 16 =
OFF
OFF
1050
[496]
1025
[484]
1015
[479]
1470
[694]
1710
[807]
1450
[684]
SW ON = SW 16 =
HIGH
ON
OFF
HEATING
CFM [L/s] SW 15 = SW 16 =
OFF
ON
800
[378]
880
[415]
950
[448]
1235
[583]
1490
[703]
1300
[614]
1200
[566]
1250
[590]
1190
[562]
1850
[873]
1965
[927]
1700
[802]
SW 15 = SW 16 =
ON
ON
700
[330]
780
[368]
900
[425]
1120
[529]
1400
[661]
1225
[578]
SW 13 = SW 14 =
OFF
OFF
910
[429]
925
[437]
900
[425]
1300
[614]
1500
[708]
1250
[590]
SW 13 = SW 14 =
LOW
ON
OFF
HEATING
SW
13
=
SW
14 =
CFM [L/s]
OFF
ON
690
[326]
750
[354]
770
[363]
1065
[503]
1335
[630]
1060
[500]
1040
[491]
1210
[571]
1050
[496]
1775
[838]
1800
[850]
1400
[661]
SW 13 = SW 14 =
ON
ON
607
[286]
660
[311]
700
[330]
925
[437]
1210
[571]
960
[453]
SW 4 =
OFF
SW 5 =
OFF
1050
[496]
1050
[496]
1050
[496]
1750
[826]
1750
[826]
1750
[826]
SW 4 =
HIGH
ON
COOLING
CFM [L/s] SW 4 =
OFF
SW 5 =
OFF
875
[413]
875
[413]
875
[413]
1400
[661]
1400
[661]
1400
[661]
SW 5 =
ON
700
[330]
700
[330]
700
[330]
1225
[578]
1225
[578]
1225
[578]
SW 4 =
ON
SW 5 =
ON
525
[248]
525
[248]
525
[248]
1050
[496]
1050
[496]
1050
[496]
SW 4 =
OFF
SW 5 =
OFF
788
[372]
788
[372]
788
[372]
1313
[619]
1313
[619]
1313
[619]
SW 4 =
LOW
ON
COOLING
SW
4=
CFM [L/s]
OFF
SW 5 =
OFF
656
[310]
656
[310]
656
[310]
1050
[496]
1050
[496]
1050
[496]
SW 5 =
ON
525
[248]
525
[248]
525
[248]
919
[434]
919
[434]
919
[434]
SW 4 =
ON
SW 5 =
ON
394
[186]
394
[186]
394
[186]
788
[372]
788
[372]
788
[372]
*S = Standard Models
NOTE Standard model complies with California low NOx requirements.
[
] Designates Metric Conversions.
7
Air
Accessories
R96V Series
FOR HIGH ALTITUDES:
VENT TERMINATION KITS: =
RXGY-E02: Vertical/Horizontal Concentric Vent Termination Kit
2" Pipe (US Only)
RXGY-E02A: Vertical/Horizontal Concentric Vent Termination Kit
2" Pipe (US & Canadian)
RXGY-E03: Vertical/Horizontal Concentric Vent Termination Kit
3" Pipe (US Only)
RXGY-E03A: Vertical/Horizontal Concentric Vent Termination Kit
3" Pipe (US & Canadian)
RXGY-G02: Direct Vent Furnace Side Wall Vent 2" or 3" (US Only)
RXGY-D05: Combustion Air Drain Kit 2"
RXGY-D06: Combustion Air Drain Kit 3"
NEUTRALIZER KIT: RXGY-A01
(Replacement Cartridge 54-22120-01)
EXTERNAL BOTTOM FILTER (UPFLOW/HORIZONTAL) RACK:
RXGF-CB
NOTE: For Canadian installations only, an optional derate (manifold
gas pressure reduction) method may be used to adjust the
furnace for altitude. See Installation Instructions for more
information. This optional method may NOT be used for U.S.
installations. See installation instructions as appropriate orifice
change is required.
L.P. CONVERSION KIT: RXGJ-FP34
CONDENSATE PUMP KIT: PROSTOCK & 1PCB151TUL
DOWNFLOW/HORIZONTAL CONVERSION KIT: RXGY-CK
DOWNFLOW/HORIZONTAL LEFT ZERO CLEARANCE
CONVERSION KIT: RXGY-ZK
COMBUSTIBLE FLOOR BASE: RXGC-B17
RXGC-B21
RXGC-B24
ECONET CONTROL
RECOMMENDED COMMUNICATING FURNACE CONTROL
EXTERNAL SIDE (UPFLOW) FILTER RACK: RXGF-CD
EXTERNAL (DOWNFLOW) FILTER RACK: RXGF-CC
FILTER RACK FILTER SIZES* INCHES [mm]
MODEL
RXGF-CB
(UPFLOW/
HORIZONTAL)
RXGF-CD
(UPFLOW)
RXGF-CC
(DOWNFLOW)
R96VA040
153/4 x 25
[400 x 635]
153/4 x 25
[400 x 635]
12 x 20
[305 x 508]
R96VA060
153/4 x 25
[400 x 635]
153/4 x 25
[400 x 635]
12 x 20
[305 x 508]
R96VA070
153/4 x 25
[400 x 635]
153/4 x 25
[400 x 635]
12 x 20
[305 x 508]
R96VA085
191/4 x 25
[489 x 635]
153/4 x 25
[400 x 635]
12 x 20
[305 x 508]
R96VA100
191/4 x 25
[489 x 635]
153/4 x 25
[400 x 635]
12 x 20
[305 x 508]
R96VA115
223/4 x 25
[578 x 635]
153/4 x 25
[400 x 635]
14 x 20
[356 x 508]
*Filter racks are shipped without filters.
Filters shipped with furnace may be used or a suitable 1" [25.4 mm] filter.
[
] Designates Metric Conversions
INDOOR COIL CASINGS
MODEL
NUMBER
RXBC-D17A1
RXBC-D21A1
RXBC-D21B1
RXBC-D24A1
RETST600SYS
CONTRACTOR BENEFITS:
• Auto/Self Configuration
• Day-at-a-glance scheduling, with programmable fan
• Intuitive wiring connections
• Dual fuel ready
• Automatically optimizes airflow
• System status & mode information
• Complete diagnostic information on display
HOMEOWNER BENEFITS:
• Large, easy to read icons and characters
• Auto-mode control
• Smart recovery
• Continuous Fan Mode (5 speeds)
• Humidity Control
• Water heater, pool heater integration* (check model compatibility)
*ECONET CONTROL ACCESSORIES:
Wall Plate = RCPN-AMC08
Face Plate = RETSTFPL
IMPORTANT: Existing Comfort Control 2 System Condensing Units &
Heat Pumps are compatible with EcoNet when matched with a R96V
Gas Furnace and with an EcoNet Translator (RETRN620CC2) installed
on the Comfort Control 2 System control board.
*Available through PROSTOCK®.
8
Air
Limited Warranty
R96V Series
GENERAL TERMS OF LIMITED WARRANTY*
Rheem will furnish a replacement for any part of this product
which fails in normal use and service within the applicable
period stated, in accordance with the terms of the limited
warranty.
*For complete details of the Limited and Conditional Warranties, including
applicable terms and conditions, contact your local contractor or the
Manufacturer for a copy of the product warranty certificate.
Parts ............................................................Ten (10) Years
Heat Exchanger .........................................Limited Lifetime
Limited Lifetime
Conditional Unit Replacement
(Registration Required) ...............................Ten (10) Years
9
Air
10
Notes
R96V Series
Air
Notes
R96V Series
11
The new degree of comfort.™
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Heating, Cooling & Water Heating • P.O. Box 17010
Fort Smith, Arkansas 72917 • www.rheem.com
Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1
Brampton, Ontario • L6Y 0P5
PRINTED IN U.S.A. 1/17 QG FORM NO. G11-540 REV. 6
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project