Optimus Pressure Scanning System OVERVIEW FEATURES

Optimus Pressure Scanning System OVERVIEW FEATURES
Optimus
Pressure Scanning System

Windtunnel Pressure Scanning System

ESP Pressure Scanner Compatible

Up to ± 0.03% Accuracy

Up to 2000 Hz/port EU Data Throughput

DTC Digital Temperature Compensation

Miniature Scanner Digitizing Interface

On Line Calibration

On Line Verification

8400 System Command Compatibility
OVERVIEW
The Optimus Data System is a pressure scanning solution designed specifically for windtunnel applications. The
Optimus System Processor manages a configurable measurement solution that provides high precision and
throughput data for up to 2048 measurement channels. Pressure is measured with ESP Miniature Pressure
Scanners or the new MicroScanners, and then converted to a digital value within the mSDI Miniature Scanner
Digitizer Interface units. Engineering Unit measurement values are calculated within the Optimus System
Processor and reported via Ethernet at data rates up to 1GBit/second. Users preferring to calculate engineering
unit data in their own host computer can receive measurement values in binary format via the Ethernet interface.
System components include PCU Pressure Calibration Units to provide precise pressure calibration and
performance verification information prior to start of test. Fiber Optic Interface Units, OFIU’s, combined with the
mSDI utilize single fiber cable to provide noise free communication between the pressure scanners and system
processor.
FEATURES








Miniature interface
High data rates
DTC technology
Sensor excitation feedback
Pressure calibration units
Fiber optic communication
ESP pressure scanner compatibility
8400 software compatibility
Optimus
BENEFITS








Direct placement within model
Transient data information
Highest industry accuracy
Stable readings
Fast, accurate calibration & verification
Minimizes cable load on force balance
Preserves previous hardware investment
Preserves previous software investment
www.meas-spec.com
1/12
July 2015
Optimus
Pressure Scanning System
SYSTEM INTRODUCTION
The Optimus Data System provides accurate high speed pressure acquisition of ESP and MicroScanner
Pressure Scanner data for windtunnel test and measurement applications. The system is configurable for low
speed, transonic, supersonic and hypersonic windtunnels with low and high channel count requirements.
Pressure Scanners are placed within or near the test object and connected to the measurement points on the
test object using flexible tubing. Multiple scanners are connected to the mSDI Miniature Scanner Digitizing
Interface which can be placed within the windtunnel model, sting or any convenient location up to 150 ft away
from the scanners. The mSDI and 8491 Remote Power Supply, RPS, combine to provide precise excitation
voltage to the scanners using individual scanner excitation feedback with active compensation. Each mSDI can
support up to 8 ESP or MicroScanner pressure scanners in any combination. Analog to Digital conversion takes
place within the mSDI and is transmitted via fiber optic cable to the OFIU fiber optic interface units within the
Optimus System Processor. Each OFIU supports one mSDI. Up to 4 OFIU/mSDI are supported with each
Optimus. Ethernet interface to the host computer can provide engineering unit value data or binary data for
users preferring to perform engineering unit calculation within the host computer.
Pressure Calibration Units provide precise reference pressures to perform on-line calibration or provide
verification pressures before testing is performed. Span calibration of ESP DTC-Style scanners before use
provides the highest available accuracy.
Optimus provides a convenient upgrade path for 8400 System users by utilizing the same command set and
offering compatibility with 8400 components such as: 8432/8433 Pressure Calibrators, 8491 Remote Power
Supplies, 8404 Remote Processors and ESP Pressure Scanners. Upgrades and Service Life Extension Plans
are also offered for various 8400 system components to achieve maximum performance.
Optimus is compatible with the latest MicroScanner and Gen-2 ESP pressure scanners as well as legacy ESP
scanners manufactured by the former Pressure Systems Inc ., which is now the Aerodynamic Research Group
within Measurement Specialties Inc. , a TE Connectivity company.
SYSTEM DIAGRAM
Optimus
www.meas-spec.com
2/12
July 2015
Optimus
Pressure Scanning System
OPTIMUS SYSTEM PROCESSOR (OSP)
The Optimus System Processor (OSP) is the central data acquisition and control unit of the Optimus Pressure
Scanning System. Configured for 19 inch rack or bench top installation, the OSP can support up to 32 pressure
scanners for a total of 2048 measurement channels. Ethernet interface allows direct host interface, networked
host interface, and expansion beyond 2048 measurement channels.
Optimus Fiber Optic Interface Units (OFIU’s) are installed inside the OSP to communicate with the Miniature
Scanner Digitizing Interface (mSDI). A minimum of one OFIU is required for system operation and up to four
OFIU’s can be installed within one OSP. The OFIU’s can be factory installed at time of system production, or
can easily be installed by the end user.
Data acquisition is initiated by the host computer which instructs the OSP to: acquire only one data point per
request, stream data at specified rates, or send data upon receipt of a hardware trigger. Data output is flexible
and can consist of multiple averages with engineering unit output. Data can also be delivered in raw binary
format for users who prefer to perform averaging and or engineering unit calculations within the host computer.
Maximum performance of Optimus is achieved with current production ESP and MicroScanner pressure
scanners. Accuracy, throughput, cable length and other limitations may exist with previous generations of ESP
pressure scanners.
OPTIMUS FIBER OPTIC INTERFACE UNIT (OFIU)
The Optimus Fiber Optic Interface Unit (OFIU) is a system component inside the OSP. It is a module that
provides noise free data communication via 62.5 micron multimode fiber cable between the OSP and the mSDI
scanner interface. The fiber optic cable extends the OSP to mSDI distance. The thin flexible cable lets users
place the mSDI within windtunnel models and bring data through the sting and perform simultaneous pressure
and force balance measurements.
Each OFIU interfaces with one mSDI. A minimum of one OFIU is required for system operation with a maximum
of four OFIU’s able to be installed inside each OSP. The cable termination is via industry standard ST fiber optic
connectors which are pre-installed within each OSP. The number of OFIU’s to be installed is specified at time of
order. Existing systems can be expanded by the user with the installation of additional OFIU’s.
MINIATURE SCANNER DIGITIZING INTERFACE (MSDI)
The Miniature Scanner Digitizing Interface (mSDI) is the connection point for the cables leading to the pressure
scanners. The mSDI provides regulated power to the scanners, facilitates excitation feedback measurement and
conducts analog to digital (A/D) conversion at high data rates.
The small size and low power dissipation of the mSDI makes it ideal for locating inside of most windtunnel
models. Cross sectional area was designed to match the ESP-64HD scanner, allowing the mSDI to be placed
in-line with the pressure scanners for maximum channel density.
Data interface from the mSDI to the OFIU is via the OFCA fiber optic cable terminated on industry standard ST
connectors. Power is supplied from the 8491 Remote Power Supply (RPS) which in turn is distributed to each
pressure scanner via the mSDI. The mSDI connects to the ESP pressure scanners with the OSCB cable, which
can vary between 6 inches and 150 feet in length when using the latest Gen-2 version of ESP pressure
scanners. Pressure scanner installation can vary between one 16-channel scanner and eight 64-channel
scanners, all on different length OSCB cables. OSCB cables utilize standard miniature sub-D 15 pin connectors
to mate with all standard ESP pressure scanners.
Optimus
www.meas-spec.com
3/12
July 2015
Optimus
Pressure Scanning System
REMOTE POWER SUPPLY (RPS)
The Remote Power Supply (RPS-Model 8491) provides precisely regulated power to the mSDI which in turn
distributes the power to the connected pressure scanners. +12, -12, and +5VDC power rails are monitored and
automatically adjusted to ensure proper voltage levels are maintained, even when power demands vary from
temperature variations, cable length variations or any mixture of legacy and new scanners.
The RPS connects to the mSDI with the 8476 cable, or user manufactured equivalent, which can vary between
1 and 300 ft in length. The RPS uses excitation sense feedback to constantly monitor and adjust power to
ensure proper excitation signals to the scanners under different configurations. This monitoring and adjustment
also corrects for temperature induced changes in cable resistance during use.
The RPS is configured for 19 inch rack mount installation or bench mount use. Each RPS can support two
mSDI. Multiple RPS are required for installations with more than two mSDI. The 8476 cable can connect to one
mSDI or the OFCY (Y-Cable) can be used to split the 8476 power to two separate mSDI.
The RPS is a Legacy 8400 System Product. Users with existing 8400 Systems considering upgrading to
Optimus may require a minor modification to their existing RPS to be compatible with the latest generation of
pressure scanners.
PRESSURE CALIBRATION UNIT (PCU)
The Pressure Calibration Unit (PCU) is a high accuracy servo-controlled pressure generation instrument. Its
function is to provide accurate and precise pressure to the ESP Scanners for the purpose of performing
calibration or pre-test verification. System configuration allows the user to pre-program the pressure set points
to use during calibration. When commanded to start a calibration sequence the PCU sets and reports the exact
pressure applied to the pressure scanners. Use of PCU’s can provide system accuracy better than +/- 0.03%
Full Scale. The pressure range of the PCU is selected to match the pressure range of the scanner for most
accurate calibration. The system is designed to use multiple PCU’s in parallel to perform rapid and precise
calibration for configurations using a variety of measurement pressure ranges during one test. Up to twelve
different pressure ranges and a total of 2048 measurement channels can be calibrated in parallel in
approximately 90 seconds.
Each PCU uses externally supplied source pressure brought in from the pneumatic backplane of the Remote
Processor (RP) then precisely regulates and maintains the desired calibration pressure. Users interface to the
PCU’s via software commands to the OSP. Typical calibration consists of 2-5 pressures set in succession over
the span of the pressure scanners measurement range. The PCU’s are also used to perform an Auto Accuracy
Test (AAT) where the user sets specific pressures and verifies accuracy of the ESP Pressure Scanners.
The PCU is also available as a measurement-only instrument called the Pressure Standard Unit (PSU). The
PSU has the same physical configuration as the PCU, incorporates the same high accuracy measurement
sensor but without the controller hardware. The purpose of the PSU is to measure and continuously monitor
important windtunnel pressures not associated with the primary test object measurement. Barometric pressure,
tunnel static pressure and tunnel wall pressure are examples of measurements made with PSU’s. The PCU can
also operate in measurement-only mode, like the PSU, allowing it to be used to make measurements while not
being used to set pressures.
PCU’s and PSU’s are Legacy 8400 System Products. Users with existing 8400 Systems considering upgrading
to Optimus may use existing PCU/PSU’s without modification. Units older than 10 years are recommended to
have the original battery backed RAM (BB RAM) replaced and consider a Service Life Extension Plan (SLEP) to
refurbish damaged or heavily used units.
Optimus
www.meas-spec.com
4/12
July 2015
Optimus
Pressure Scanning System
REMOTE PROCESSOR (RP) AND LOCAL SLAVE (LS)
The 8400 Remote Processor (RP) and Local Slave (LS) are rack mounted interfaces for the PCU and PSU.
They provide complete pneumatic, electrical and communications interface for the PCU’s and PSU’s. Up to four
PCU/PSU’s can be mounted within one RP. All pneumatic connections are conveniently routed thorough a
unique pneumatic bus on the backplane of the RP, allowing convenient and automatic pressure connection
between the PCU/PSU’s supply pressure and output to the pressure scanners.
The RP is a rack mounted instrument that can be mounted near the OSP, or remotely near the pressure
scanners. Mounting the RP closer to the pressure scanners reduces the length of the pressure calibration lines
which may improve calibration speed due to reduced pressure settling time in the large volume associated with
long calibration lines.
The RP communicates to the OSP via serial RS-485 using the 8484 cable and contains an internal power
supply for AC input compatibility. Up to three RP’s can be connected to one OSP for a total interface of 12
PCU/PSU’s.
A Local Slave (LS) can be connected to the Remote Processor to expand the number of PCU’s supported by
the system. The LS receives power from the RP and communicates to the OSP through the RP. As such it is
located in close proximity to the RP.
The RP, LS and associated cables are Legacy 8400 System Products. Users with existing 8400 Systems
considering upgrading to Optimus can use properly operating units without modification or service requirements.
Optimus
www.meas-spec.com
5/12
July 2015
Optimus
Pressure Scanning System
SYSTEM CABLES
The Optimus System incorporates a variety of function-specific cables to achieve highly accurate, fast and
reliable operation for a broad range of windtunnel types. Each cable has been carefully selected and designed
to achieve specific functions common to most windtunnels. Detailed cable diagrams and cable design
assistance are available to users desiring to manufacture custom cables to meet requirements unique to their
own installation. It is recommended to have one complete set of factory produced cables for troubleshooting
purposes. The following describes the function of each cable, starting with connections at the pressure
scanners.
OSCB – Optimus Scanner Cable
The OSCB connects ESP pressure scanners to the mSDI scanner interface. It is available in lengths from 6
inches to 150 ft. Any combination of cable lengths can be utilized since the RPS automatically adjusts system
power load and pressure scanner excitation on a per-scanner basis. The OSCB is an improved version of the
PSCB cable with specific shielding and pin locations to minimize power to signal interference. The connector
gender has been changed at the mSDI to prevent accidental reversal of the cable while maintaining standard
ESP/MicroScanner pressure scanner connector compatibility. A PSCB cable may be modified to functional
equivalent of OSCB cable with connector change for lengths up to 90 ft. OSCB cable has one additional shield
wire connected at scanner end which provides improved performance for lengths over 90 ft.
OFCA – Optimus Fiber Optic Cable
The OFCA provides noise free data communication between the mSDI scanner interface and the OFIU fiber
optic interface located within the OSP. Industry standard, reliable metallic ST connectors are used at both ends
of the cable. Full duplex communication between the mSDI and OFIU allows the use of just one fiber to
simultaneously transmit and receive reliable high speed communication between the two system components.
The mSDI and OFIU communicate at 1310 and 1550 nm via 62.5 micron multimode fiber, allowing existing 8400
users to utilize existing 8474 fiber optic cables without modification. We offer OFCA cables in discrete lengths
up to 91 meters (300 ft). The system has been verified for use with cables up to 1 kilometer.
8476 Power Cable
The 8476 provides accurate, regulated power to the mSDI from the RPS. It is available in any length between 1
ft and 300 ft. Existing 8400 users can use existing 8476 cables without modification.
OPCY Y-Cable
The Y-Cable connects the 8476 cable and mSDI. It functions as a splitter to expand RPS power to two separate
mSDI. Excitation feedback to provide the required precise scanner excitation is maintained with this cable
design. The two legs of the Y-Cable can be different lengths with an overall length limitation of 6 ft. (2 meter
designation also available).
Optimus
www.meas-spec.com
6/12
July 2015
Optimus
Pressure Scanning System
MECHANICAL MODELS
MM – Mechanical Models
Anodized aluminum mechanical models, MM, of ESP pressure scanners and mSDI interface are available to
assist with model installation. These items allow the functional ESP and mSDI instruments to be used for
existing testing while providing mechanically equivalent units to assist with tubing and wiring installation of future
test models. Upon completion of tubing and wiring connections the transition to test configuration is quick and
convenient. The mechanical models are removed and the functional instruments can be installed and rapidly
connected to precisely located quick disconnects plates and cables.
SOFTWARE COMMANDS & 8400 COMMAND SET COMPATIBILITY
The Optimus utilizes much of the same command set as the 8400 System. Commonly used 8400 commands
have been preserved. Most 8400 users will be able to convert existing installations with a minimum of software
investment. A list of currently implemented commands is available. Command list review with a factory
applications engineer is recommended for 8400 users planning to re-use existing software.
UTILITY SOFTWARE
Windows compatible start up software is provided at no charge with the system and via our website. The
software allows users to quickly operate a complete system to confirm system operation, acquire data, log data
and analyze data. It also provides convenient program development support by allowing users to send and
receive responses to specific programming commands. A large number of convenient functions are included
which may be used independent of user run time software, such as:
A.
B.
C.
D.
E.
F.
G.
Auto System Configuration – Identifies system components based on DTC technology
System Calibration – Coordinates calibration of all scanners with appropriate calibrators
Auto Accuracy Test – Utility to perform automated system calibration and accuracy test
Channel Check – Utility to confirm proper tubing connections within model
IP Address Change – Configures system to match network parameters
Scanner Utilities – Monitors and configures important pressure scanner parameters
Real Time FFT – Excel link to analyze high speed data
Optimus
www.meas-spec.com
7/12
July 2015
Optimus
Pressure Scanning System
Physical Specifications
OSP
OFIU
mSDI
RPS
PCU
RP
PBU
ESP
Uni ts
Comments
Ca pa ci ty
1
1-4
1-4
1-4
1-12
1-3
6 ma x
requi red
1-32
Uni ts
Expa nda bl e
vi a Ethernet
Ma teri a l
Steel &
Al umi numPa i nted
Pri nted
Ci rcui t
Boa rds
Opera ti ng
Tempera ture
0-50
0-50
-25 to 80
0-50
0-50
0-50
0-50
-25 to 80
°C
Stora ge
Tempera ture
0-80
0-80
-25 to 100
0-80
0-80
0-80
0-80
-25 to 100
°C
Rel a ti ve
Humi di ty
5-95
5-95
5-95
5-95
5-95
5-95
5-95
5-95
%
Va cuum &
Pres s ure
10-16
10-16
0.0002 to
150
10-16
10-16
10-16
10-16
0.0002 to
150
PSI
Abs ol ute
Vi bra ti on
N/A
N/A
10
N/A
N/A
N/A
N/A
10
g a t 15 to
2000 Hz
Shock
N/A
N/A
30
N/A
N/A
N/A
N/A
30
g Pea k
Sea l i ng
IP-20
N/A
IP-50
IP-20
IP-40
IP-20
IP-50
IP-40
AC
Interna l
from OSP
From RPS
AC
Interna l to
RP
AC
N/A
From mSDI
To ESP
To mSDI
Interna l to
RP
RS-485 to
OSP
N/A
To mSDI
To OFIU
N/A
N/A
N/A
N/A
N/A
Pa ra meter
Physical
Steel &
Al umi num Al umi num Al umi num
Al umi numAl umi num- Iri di ted & Iri di ted & Iri di ted &
Anodi zed
Pa i nted
Pa i nted
Pa i nted
Pa i nted
Steel &
Anodi zed
Al umi num
Environmental
NonCondens i ng
Connections
El ectri ca l
Input
El ectri ca l
Output
Fi ber Opti c
Pneuma ti c
Ethernet & Interna l to
RS-485
OSP
vi a OFIU
N/A
To mSDI
N/A
N/A
N/A
Interna l to
RP
To ESP
Interna l
from OSP
From RPS
Speci fi ed
100, 110,
220
From RP
Speci fi ed
100/110,
220
Mea s urements
Sea l s
from
Unus ed RP
model &
Sl ots
Ca l vi a
RP/PCU
Power
Power Input
Optimus
Uni vers a l
100-240
www.meas-spec.com
8/12
N/A
From mSDI
V ol ts AC
50 or 60 Hz
July 2015
Optimus
Pressure Scanning System
Performance Specifications - DTC ESP Scanners
Number of Pres s ure Inputs
Mi croSca nner 16
DTC (NEW)
16
ESP-32HD DTC
Gen-2 (Current)
32
ESP-64HD DTC
Gen-2 (Current)
64
ESP-32HD DTC
Gen- 1 (Previ ous )
32
ESP-64HD DTC
Gen-1 (Previ ous )
64
Uni ts
Comments
Ports
Throughput In Engi neeri ng
Uni ts
2000
1000
500
650
325
Hz Per Port
Si ngl e
poi nt
a vera gi ng
Res ol ution
0.001
0.001
0.001
0.003
0.003
% Ful l Sca l e
Noi s e
Fl oor
Ana l ys i s
0.05
0.03
0.03
0.03
0.03
0.08
0.05
0.05
0.05
0.05
± % Ful l
Sca l e
± % Ful l
Sca l e
32 poi nt
a vera gi ng
32 poi nt
a vera gi ng
N/A
0.06
0.06
0.06
0.06
± % Ful l
Sca l e
32 poi nt
a vera gi ng
N/A
0.15
0.15
0.15
0.15
± % Ful l
Sca l e
32 poi nt
a vera gi ng
Total Therma l Effect a t Ful l
Ra nge 5 ps i d to 150 ps i d
0.002
0.002
0.002
0.002
0.002
± % Ful l
Sca l e Per °C
Total Therma l Effect a t 33%
Ra nge 5 ps i d to 150 ps i d
0.003
0.003
0.003
0.003
0.003
± % Ful l
Sca l e Per °C
Total Therma l Effect a t Ful l
Ra nge 10" WC to 2.5 ps i d
N/A
0.004
0.004
0.004
0.004
± % Ful l
Sca l e Per °C
Total Therma l Effect a t Ful l
Ra nge 4" WC
N/A
0.010
0.010
0.010
0.010
± % Ful l
Sca l e Per °C
Ma xi mum Reference
Pres s ure
50
50
50
50
50
PSI
Di fferentia l
Li ne Pres s ure Effect
0.001
0.001
0.001
0.001
0.001
± % Ful l
Sca l e Per
PSI
Static Accura cy a t Ful l
Ra nge
15 ps i d
Static Accura cy a t 33%
Ra nge
5 ps i d
Static Accura cy a t Ful l
Ra nge
10" WC to 2.5
ps i d
Static Accura cy a t Ful l
Ra nge
4" WC
Optimus
www.meas-spec.com
9/12
July 2015
Optimus
Pressure Scanning System
Performance Specifications - Conventional & Legacy ESP Scanners
ESP-16HD
Conventiona l
ESP-32HD
Conventiona l
ESP-64HD
Conventiona l
ESP - Lega cy
Model s
Uni ts
16
32
64
16,32,48
Ports
Accura cy a t Ful l Ra nge
0.05
0.05
0.05
0.05
± % Ful l Sca l e
Accura cy a t 33% Ra nge
N/A
N/A
N/A
N/A
Total Therma l Effect
0.080
0.080
0.080
0.200
± % Ful l Sca l e Per
°C
Throughput In
Engi neeri ng Uni ts
1000
650
325
100
Hz Per Port
Si ngl e poi nt
a vera gi ng
Res ol ution
0.003
0.003
0.003
0.003
± % Ful l Sca l e
Noi s e Fl oor
Ana l ys i s
50
50
50
N/A
PSID
0.001
0.001
0.001
N/A
± % Ful l Sca l e Per
PSI
Number of Pres s ure
Inputs
Ma x Reference Pres s ure
Li ne Pres s ure Effect
Optimus
www.meas-spec.com
10/12
Comments
32 poi nt a vera gi ng
Onl y a va i l a bl e
wi th DTC
July 2015
Optimus
Pressure Scanning System
SYSTEM CONFIGURATION AND ORDERING INFORMATION
The following items are required to configure an Optimus Pressure Scanning System. Please coordinate with
your factory contact or local distributor to determine appropriate options, potential re-use or refurbishment of
existing 8400 equipment, part numbers and pricing.
OSPR Optimus System Processor, Universal AC, Rack and Bench Mount, Completely Configured
OFIU Optimus Fiber Optic Unit, PC Board for installation within Optimus System Processor
 Installed by Factory
 Installed by User
mSDI Miniature Scanner Digitizing Interface, up to 8 ESP scanners, Completely Configured
RPS
Remote Power Supply, for use with 1 or 2 mSDI
 Power, 100, 110 or 220 VAC
 Upgrade required if re-using existing unit
PCU Pressure Calibration Unit, used for calibration, located within RP or LS
 Pressure range
 Service available and recommended for re-using existing units older than 10 years
PBU Pneumatic Blanking Unit, used to fill unused slots of RP or LS
RP
Remote Processor, communicates with OSP, contains PCU’s, provides calibration to scanners
OSCB Scanner cable, connects ESP to mSDI
 Length, min 6 inches, max 150 ft with Gen-2 ESP scanners, max 30 ft with other ESP scanners
 Jacket material, PVC standard, PTFE optional
 Units of measure, inches, feet or meters
OFCA Fiber Optic Cable, ST connectors, single fiber, connects mSDI to OFIU, available up to 91 meters
8476 Power cable, RPS to mSDI
 Length, 300 ft max
 Connector type for RPS connection, circular for new installations, d-shell for replacement only
OPCY Y-Cable, splits 8476 cable for use with 2 mSDI, total length 6 ft
 Length of left portion
 Length of right portion
MM
Mechanical Models, used during model build in place of scanners and mSDI
 Type of scanner
 mSDI
ESP
Pressure Scanners
 MicroScanner or ESP
 Pressure range
 Connection size
 Quick disconnect plate
 With or without purge
Digital Temperature Compensation or Conventional
Optimus
www.meas-spec.com
11/12
July 2015
Optimus
Pressure Scanning System
ORDERING INFORMATION
Measurement Specialties Inc.
Aerodynamic Research Group
1000 Lucas Way
Hampton VA, 23666 USA
Tel: 757-766-1500
Fax: 757-766-4297
Sales: pvg.cs.amer@meas-spec.com
The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed f or inaccuracies.
Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the manufacturer.
Measurement Specialties, Inc. reserves the right to make changes without further notice to any product herein. Measurement Sp ecialties, Inc. makes
no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does Measurement Specialties, Inc.
assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability, including without
limitation consequential or incidental damages. Typical parameters can and do vary in different applications. All operating parameters must be
validated for each customer application by customer’s technical experts. Measurement Specialties, Inc. does not convey any li cense under its patent
rights nor the rights of others
Optimus
www.meas-spec.com
12/12
July 2015