2
Turbidity and Chlorine . .4-9, 24-25, 27
Single Parameter Photometers . . .26-28
Solutions for pH Electrodes . . . . . . . .33
pH and ISE . . . . . . . . . . . . . . . . . . . . . .10-15
Stirrers . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
ISE Electrodes . . . . . . . . . . . . . . . . . . . . .34
Alkalinity Titration . . . . . . . . . . . . .16-17
Temperature Monitor . . . . . . . . . . . . . .30
ISE Solutions . . . . . . . . . . . . . . . . . . . . . . .35
Multiparameter Titration . . . . . . .18-19
pH and ORP Electrodes . . . . . . . . . . . .31
Multiparameter Photometer . . .20-23
pH and ORP Solutions . . . . . . . . . . . . . .32
Water sector professionals choose HANNA as part of
their drinking water monitoring strategy because of our
performance, quality and value.
3
{
Instruments built to comply with
EPA accepted test methods for
reporting Turbidity and Chlorine
}
Turbidity and Chlorine Meters
• HI 83414 features 4 ranges:
Ratio Turbidity; Non-Ratio Turbidity;
Free Chlorine; Total Chlorine
• HI 88703 features 2 ranges:
Ratio Turbidity; Non-Ratio Turbidity
• Meets USEPA requirements
• CAL CHECK™ for HI 83414
• 2, 3, 4 or 5 point turbidity calibration
• Backlit LCD
• On-screen tutorial modes
• Log and recall up to 200 measurements
• Contextual help menus
• Auto shut-off
• Automatic range selection
• Good Laboratory Practice capabilities
• Features USB PC connection
Built for Accuracy
The HI 83414 tests both of the most important parameters of drinking water: turbidity and free/total chlorine. The HI 88703
measures turbidity only and is especially designed for dedicated stations that require a single parameter.
The HI 83414 and HI 88703 meet and exceed the requirements of USEPA and Standard Methods and provide reliable and accurate
readings on low turbidity values.
Turbidity measurements can be made in the 0.00 to 40.0 NTU (Nephelometric Turbidity Units) range when non ratio method is
used or 0.00 to 4000 NTU range when ratio measurements are used. The instrument has an EPA compliance reading mode which
rounds the reading to meet EPA reporting requirements.
A choice of normal measurement, continuous measurement or signal averaging measurement can be selected depending upon
your SOP. Two, three, four or five-point calibration can be performed by using the supplied (<0.1, 15, 100, 750 and 2000 NTU)
standards. When user prepared standards are used, the calibration points can be modified.
4
With Great Products, Come Great Results™
GLP
Log and Recall
Calibration Error Messages
Built in complete GLP information.
Store up to 200 records.
Help Mode
Tutorial Mode
CAL CHECK™
Both meters offer interactive contextual
help to assist users during measurements.
Provides additional information to help
users during measurements.
CAL CHECK™ allows users to check instrument
calibration against a NIST traceable standard
before making a set of measurements. With the
same standard, the instrument could be recalibrated if necessary.
Turbidity in Potable Waters
Turbidity is one of the most important parameters used to determine the quality of drinking water. Public water suppliers are required
to treat their water to remove turbidity. Adequately treated surface water does not usually present a turbidity problem. The World
Health Organization indicates 5 FTU as the reference turbidity value of water for trade. This value has been established based on the
aesthetic characteristics of water. From a hygienic point of view, 1 FTU is the recommended value. Turbidity is an indicator and will not
give results for a specific pollutant. It will, however, provide information on the degree of overall contamination.
TURBIDITY SPECIFICATIONS
ORDERING INFORMATION
0.00 to 9.99; 10.0 to 40.0 NTU
Range—Non Ratio Mode
0.01; 0.1 NTU
Resolution—Non Ratio Mode
0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU
Range—Ratio Mode
0.01; 0.1; 1 NTU
Resolution—Ratio Mode
±2% of reading plus 0.02 NTU
±5% of reading above 1000 NTU
Accuracy
Repeatability
HI 88703-01 (115 V) and HI 88703-02 (230 V)
are supplied with (5) sample cuvettes and caps,
calibration cuvettes, silicone oil (HI 93703-58),
cuvette cleaning cloth, power cord and instructions.
HI 83414-01 (115 V) and HI 83414-02 (230 V) are
supplied with (5) sample cuvettes and caps, calibration
cuvettes for turbidity meter and colorimeter (HI 8341411), silicone oil (HI 93703-58), cuvette cleaning
cloth, scissors, power cord and instructions.
±1% of reading or 0.02 NTU whichever is greater
< 0.02 NTU
Stray Light
Silicon photocell
Light Detector
SOLUTIONS
HI 93414-11 CAL CHECKTM Calibration set for
Free & Total Chlorine
HI 93701-01 Reagents for 100 Free Chlorine tests
Method
Adaptation of the USEPA Method 108.1 and Standard Method 2130 B.
Normal, Average, Continuous
Measuring Mode
HI 93701-03 Reagents for 300 Free Chlorine tests
HI 93711-01 Reagents for 100 Total Chlorine tests
HI 93711-03 Reagents for 300 Total Chlorine tests
<0.1, 15, 100, 750 and 2000 NTU
Turbidity Standards
FREE AND TOTAL CHLORINE SPECIFICATIONS – HI 83414 ONLY
Range
Resolution
HI 88703-11 Calibration set for turbidity meter
(<0.1, 15, 100, 750 and 2000 NTU)
HI 93703-50 Cuvette cleaning solution, 250 mL
Free Cl2: 0.00 to 5.00 mg/L; Total Cl2: 0.00 to 5.00 mg/L
0.01 mg/L from 0.00 to 3.50 mg/L; 0.10 above 3.50 mg/L
ACCESSORIES
HI 93703-58 Silicone oil, 15 mL
Accuracy
±0.02 mg/L @ 1.00 mg/L
HI 731318
Cuvette cleaning cloth (4)
Detector
Silicon photocell with 525 nm narrow band interference filters
HI 731331
Glass cuvettes (4)
HI 731335N Caps for cuvettes (4)
Method
Adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G.
Standards
www.hannanorden.com
1 mg/L free chlorine, 1 mg/L total chlorine
HI 740234
Lamp for EPA turbidity meter
HI 92000
Windows® compatible software
HI 920013
USB cable for PC connection
5
{
Instruments built to comply with
USEPA accepted methodology for
reporting Turbidity and Chlorine
}
Turbidity and Chlorine Meters
Turbidity and Free/Total Chlorine Meters
The HI 93414 measures two of the most important parameters of drinking water: turbidity and free and total chlorine
while the HI 98703 measures turbidity only.
Both meters are EPA compliant and feature 3 turbidity measurement ranges: 0.00 to 9.99 NTU, 10.0 to 99.9 NTU,
and 100 to 1000 NTU.
Reliable performance of the HI 93414 is validated using HANNA's exclusive CAL CHECK™ system and ready-made, NIST
traceable chlorine standards.
Computer Compatible
With our HI 92000 Windows® compatible application software, users can sort and filter all collected test data using different
criteria such as specific sampling location, parameter, date and time intervals or fixed range to filter measured values. The data
can be plotted in a graph, exported to other common Windows® applications or printed for reporting purposes.
6
With Great Products, Come Great Results™
• Tungsten light source—EPA compliant turbidity
measurement
• High accuracy at low ranges
• Exclusive chlorine CAL CHECK™ calibration validation
(HI 93414 only)
• Log up to 200 readings
• User replaceable light source
• 2, 3 or 4 point turbidity calibration
• USB and RS232 PC connectivity
• Backlit LCD
• GLP capability
• User friendly display with guidance codes
• Auto shut-off
• Battery percentage on display
• Continuous current time on display
{
A Revolution in Organized
Data Management
}
Fast Tracker™ Tag Identification System (T.I.S.)
HANNA’s exclusive Fast Tracker™ — Tag Identification System simplifies
test logging while retaining the management versatility users need to
search, filter and export data. The system, ideal for on-site spot checks,
helps verify that samples have truly been taken at pre-established locations
during safety audits and inspections.
Fast Tracker™ is easy to install and operate. Just install the iButton® tags
near the sample sites. These meters identify and authenticate logged data
by storing the iButton® serial number, time and date stamp by simply
touching the iButton® with the matching connector on the instruments. The
number of tags that can be installed is unlimited and each tag has a unique
identification code.
Power RS232
connector
USB Fast Tracker™
www.hannanorden.com
It is easy to add new tags later on to increase an already existing database.
7
Turbidity Testing
Water clarity is paramount when producing water for human consumption. Turbidity, an optical property, is a measure of the
cloudiness of water. Turbidity causes light to be scattered and absorbed rather than transmitted. The measurement of
turbidity is used to indicate water quality and filtration effectiveness. Increases in suspended and colloidal matter increase
turbidity. These levels are often associated with higher levels of disease-causing microorganisms such as viruses, parasites
and some bacteria that can cause symptoms such as nausea, cramps, diarrhea, and associated headaches. Although
microbiological testing is also done, turbidity measurements are used with regularity to detect changes immediately. EPA
regulations require filter effluent values of 0.3 NTU (Nephelometric Turbidity Units) in at least 95 percent of measurements
taken each month with a maximum level of 1 NTU.
TURBIDITY SPECIFICATIONS
Range
Range Selection
Resolution
Accuracy
Repeatability
Stray Light
Light Detector
Light Source
Method
Measuring mode
Turbidity Standards
Calibration
ORDERING INFORMATION
0.00 to 9.99; 10.0 to 99.9 and 100 to 1000 NTU
Automatic
0.01 NTU from 0.00 to 9.99 NTU; 0.1 NTU from 10.0 to 99.9 NTU;
1 NTU from 100 to 1000 NTU
±2% of reading plus 0.02 NTU
±1% of reading or 0.02 NTU, whichever is greater
< 0.02 NTU
Silicon photocell
Resolution
Accuracy
Typical EMC Deviation
8
HI 98703-01 (115V) and HI 98703-02 (230V)
are supplied with (5) sample cuvettes and caps,
HI 98703-11 calibration cuvettes, HI 93703-58 silicone
oil, cuvette cleaning cloth, (4) 1.5V AA batteries, AC
adapter, instruction manual and rugged carrying case.
Tungsten filament lamp
Ratio Nephelometric Method (90°), ratio of scattered and transmitted light;
Adaptation of the USEPA Method 180.1 and Standard Method 2130 B.
Normal, Average, Continuous
SOLUTIONS
HI 93414-11 CAL CHECKTM Calibration set for
Free & Total Chlorine
HI 93701-01 Reagents for 100 Free Chlorine tests
<0.1, 15, 100 and 750 NTU
HI 93701-03 Reagents for 300 Free Chlorine tests
Two, three or four-point calibration
HI 93711-01 Reagents for 100 Total Chlorine tests
FREE AND TOTAL CHLORINE SPECIFICATIONS — HI 93414 only
Range
HI 93414-01 (115V) and HI 93414-02 (230V) are
supplied with (5) sample cuvettes and caps, calibration
cuvettes for turbidity meter, calibration cuvettes for
colorimeter, silicone oil, cuvette cleaning cloth, scissors,
(4) 1.5V AA batteries, AC adapter, instruction manual
and rugged carrying case.
Free Cl2 0.00 to 5.00 mg/L; Total Cl2 0.00 to 5.00 mg/L
HI 93711-03 Reagents for 300 Total Chlorine tests
HI 98703-11 Turbidity standards kit
HI 93703-50 Cuvette cleaning solution, 250 mL
0.01 mg/L from 0.00 to 3.50 mg/L; 0.10 above 3.50 mg/L
±0.02 mg/L @ 1.00 mg/L
±0.02 mg/L
Detector
Silicon photocell with 525 nm narrow band interference filter
Method
Adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G.
The reaction between chlorine and DPD reagent causes a pink tint in the sample.
Standards
1 mg/L free chlorine, 1 mg/L total chlorine
Calibration
One-point calibration
ACCESSORIES
HI 920005 iButton® Tag holders with tags (5)
HI 98703-58 Silicone oil (15 mL)
HI 93703-60 Caps for cuvettes (4)
HI 731318
Cuvette cleaning cloth (4)
HI 731331
Glass cuvettes (4)
HI 92000
Windows® compatible software
HI 920011
5 to 9 pin RS232 connection cable
HI 920013
USB cable for PC connection
With Great Products, Come Great Results™
The HI 88713 is a high accuracy meter designed for low turbidity.
This instrument exceeds the requirements of ISO 7027 standard
The HI 98713 ISO Portable Turbidity meter
meets and exceeds the requirements of the ISO
7027 for water quality.
ISO Turbidity Meters
• USB PC connectivity
• Normal, average and continuous
measuring modes
• GLP capability
• Log up to 200 records
• 2, 3 or 4 point calibration
SPECIFICATIONS
HI 88713
FNU Mode
0.00 to 9.99; 10.0 to 99.9;
100 to 1000 FNU
FAU Mode
10.0 to 99.9; 100 to 4000 FAU
Range
NTU Ratio Mode
0.00 to 9.99; 10.0 to 99.9;
100 to 4000 NTU
NTU Non-Ratio Mode
0.00 to 9.99; 10.0 to 99.9;
100 to 1000 NTU
Range Selection
Automatic
FNU Mode
0.01; 0.1; 1 FNU
FAU Mode
0.1; 1 FAU
Resolution
NTU Ratio Mode
0.01; 0.1; 1 NTU
NTU Non-Ratio Mode
0.01; 0.1; 1 NTU
FNU Mode
±2% of reading plus stray light
FAU Mode
±10% of reading
Accuracy
NTU Ratio Mode
NTU Non-Ratio Mode
Repeatability
Stray Light
Light Detector / Light Source
Method
Turbidity Standards
±2% of reading plus stray light /
±5% of reading above 1000 NTU
HI 98713
FTU Mode:
0.00 to 9.99 FTU; 10.0 to 99.9 FTU
100 to 1000 FTU
Automatic
0.01 FTU from 0.00 to 9.99 FTU
0.1 FTU from 10.0 to 99.9 FTU
1 FTU from 100 to 1000 FTU
±2% of reading plus 0.1 FTU
±2% of reading plus stray light
• Graphic, backlit display
• User friendly display with
guidance codes
ORDERING INFORMATION
HI 88713-01 (115V) and HI 88713-02 (230V) are
supplied with (6) sample cuvettes and caps,
calibration cuvettes, silicone oil, cuvette cleaning
cloth, power adapter and instructions.
HI 98713-01 (115V) and HI 98713-02 (230V) are
supplied with (5) sample cuvettes and caps, HI 9871311 calibration cuvettes, HI 93703-58 silicone oil,
cuvette cleaning cloth, (4) batteries, AC adapter,
instruction manual and rugged carrying case.
SOLUTIONS
HI 88713-11
HI 88713 turbidity meter calibration
set (<0.1, 15, 100, 750 FNU and
2000 NTU)
HI 98713-11
HI 98713 turbidity standards kit
HI 93703-50
Cuvette cleaning solution, 250 mL
ACCESSORIES
HI 920005
HI 98713 Tag holders with tags (5)
HI 98703-58
Silicone oil, 15 mL
HI 93703-60
Caps for cuvettes (4)
±1% of reading or stray light,
whichever is greater
±1% of reading or 0.1 FTU,
whichever is greater
HI 731318
Cuvette cleaning cloth (4)
HI 731331
Glass cuvettes (4)
< 0.1 NTU
< 0.1 FTU
HI 92000
Windows® compatible software
Silicon photocell / IR LED
Silicon photocell /
860 nm IR LED
HI 920011
HI 98713 5 to 9 pin RS232
connection cable
Adaptation of ISO 7027, ratio
method with 90° and 180° detector.
HI 920013
USB cable for PC connection
ISO 7027 Method
<0.1, 15, 100, 750 FNU and
2000 NTU
<0.1, 15, 100 and 750 FTU
www.hannanorden.com
9
{
Simultaneous
Dual Graph Display
}
Research Grade pH, ISE and ORP Meter
Tailored to your Application
HANNA’s new research grade laboratory
pH/mV/ISE benchtop meter features a
240 x 320 dot-matrix color display
with on-screen help, dual-channels,
simultaneous graphing, language
selection and custom configuration.
• Exclusive Calibration Check™
for pH
• 240 x 320 color display
• Simultaneous dual graph display
and real-time logging
• USB and RS232 for computer
compatibility
• Multi-language interface
• Logging, graphing and GLP
capabilities
• Manual or automatic temperature
compensation
• Relative mV scale
• Small footprint
• Dual inputs for pH, ISE or mV
modes
10
With Great Products, Come Great Results™
Extend your Parameter Measurement with Ion Selective Electrodes
Chloride (Titration) *
Fluoride (Direct) *
Nitrate (Direct) *
Chloride is a common non-toxic material
present in small amounts in drinking water
and produces a detectable salty taste at
the aesthetic objective level of 250 mg/L
(limit referred to the EPA MCL (maximum
contaminant level). Measured levels are
normally under 20 mg/L (ppm). The EPA’s
National secondary drinking water standard
for chloride is set at 250 mg/L (ppm).
Fluoride is a water additive which promotes
strong teeth. Many public water systems add
low levels of fluoride to promote better dental
health. However, erosion of natural deposits
and discharge from fertilizer and aluminum
factories can have a detrimental health effect.
The US EPA has set 4 mg/L (ppm) for MCL
(maximum contaminant level). It is also listed
as a secondary standard at 2 mg/L (ppm).
Standard Methods 4500-Cl-D Potentiometric
Method is approved by EPA for regulatory
use. This is a potentiometric titration that
can be manually made using a burette, or
automated using the HI 901 titrator. Refer to
your individual SOP for specifics.
Standard Methods 4500-F-C is an approved
method for fluoride determination using an
ion selective electrode.
The EPA set the MCL (maximum contaminant
level) for Nitrates in drinking water at 10
mg/L (ppm). Toxic release from human and
livestock waste and feedlots are potential
sources that can adversely affect drinking
water. Nitrate in drinking water can be
determined using a direct measurement
technique using a nitrate ion selective
electrode and suitable meter. The method
follows Standard Methods 4500-NO2 B.
HI 4010 fluoride ISE and HI 5315 sleeve style
reference electrode or HI 4110 combination
electrode (consult your SOP).
HI 4010-02 (100 ppm fluoride standard)
HI 4107 chloride ISE or HI 4115 silver ISE
(or half cells with HI 5315 reference)
HI 4113 or 4013 and HI 5315
HI 4013-06 (interferent suppressant ISA)
HI 4013-02 is 100 ppm standard
HI 7078 fill solution
HI 4222 research grade meter
HI 180 magnetic stirrer
HI 4010-00 (TISAB includes CDTA
for interferent suppression)
HI 70448: 0.02 M AgNO3 standard
HI 7072 electrode refilling solution
HI 7075 electrolyte solution with KNO3
and KCl (4) 30 mL bottles
HI 4222 research grade meter or HI 901 titrator
HI 4222research grade meter
HI 180 stirrer with magnetic stir bars.
HI 180 magnetic stirrer
Other suggestions:
Insulation under beaker
Volumetric pipettes for sample transfer
{
* Use meter with pH electrodes or ISE’s to
comply with EPA accepted methodology
for pH, Chloride, Fluoride and Nitrate
SPECIFICATIONS
Range
pH
HI 4222
-2.0 to 20.0; -2.00 to 20.00; -2.000 to 20.000 pH
0.1 pH; 0.01 pH; 0.001 pH
Resolution
±0.1 pH; ±0.01 pH; ±0.002 pH
Accuracy
±2000 mV
Range
mV
0.1 mV
Resolution
±0.2 mV
Accuracy
Range
ISE
-7
1 x 10 to 9.99 x 10 concentration ±0.2 mV
1; 0.1; 0.01 concentration
Resolution
Accuracy
Range
10
}
ORDERING INFORMATION
HI 4222-01 (115V) and HI 4222-02 (230V) are
supplied with glass body pH electrode,
temperature probe, power adapter, pH 4 and pH 7
buffer solutions, electrode refilling solution,
electrode holder and instructions.
SOLUTIONS
HI 5004
HI 5007
HI 5010
HI 54710
±0.5% (monovalent ions); ±1% (divalent ions)
-20.0 to 120°C; -4.0 to 248.0°F; 253.15 to 393.15K
HI 70300L
HI 7061L
Temperature
0.1°C; 0.1°F; 0.1K
Resolution
±0.2°C; ±0.4°F; ±0.2K
Accuracy
pH
Calibration
ISE
Automatic, up to 5 point calibration, 8 standard buffers available (1.68, 3.00,
4.01, 6.86, 7.01,9.18, 10.01, 12.45), and 5 custom buffers
Automatic, up to 5 point calibration, 5 fixed standard solutions available for each
measurement unit, and 5 user defined standards
Temperature
www.hannanorden.com
3 points
pH 4.01 buffer solution, 500 mL
pH 7.01 buffer solution, 500 mL
pH 10.01 buffer solution, 500 mL
pH 4.01, pH 7.01 and pH 10.01
buffer solution, 500 mL ea.
Electrode storage solution, 500 mL
Electrode cleaning solution, 500 mL
HI 50XX buffers are technical buffers with ±.01 accuracy
and are provided with certificate
ACCESSORIES
HI 76404N
HI 92000
HI 920010
HI 920013
Electrode holder
Windows® compatible software
RS232 cable for PC connection
USB cable for PC connection
11
{
Backlit
Multi-level Display
}
Calibration Check™ pH Meter
• Exclusive Calibration Check™
• Electrode condition monitoring
• Backlit, multi-level LCD with
on-screen guide
• Up to 7 standard and 2 custom
calibration buffers
• User-selectable calibration
timeout reminder
• Measures in °C or °F
• Waterproof
• Rechargeable batteries
• BEPS (Battery Error Prevention System)
Accurate and Versatile
The HI 9126 is ideal for on-site spot checks. It’s sleek, portable casing and large
LCD with backlight works with the operator to achieve fast and accurate results in
a variety of testing locations, such as tight sampling places, even in low-light.
The HI 9126 features HANNA‘s exclusive Calibration Check™ technology.
Calibration Check™ monitors the pH bulb and reference junction of the electrode
every time the instrument is calibrated. In the event of a dirty pH bulb, Calibration
Check™ prompts the user that additional cleaning may be needed.
The multi level LCD can display the primary measurement and temperature
simultaneously to save time at location sites.
The HI 9126 can be used for ORP measurements in the mV range with 0.1
mV resolution.
12
With Great Products, Come Great Results™
{
Rugged,
Waterproof Casing
}
Water sector professionals choose HANNA products as part of their drinking water
monitoring strategy because of our performance, quality and value.
SPECIFICATIONS
Range
HI 9126
pH
-2.00 to 16.00 pH
mV
±699.9 mV; ±1999 mV
Temperature
-20.0 to 120.0°C / -4.0°F to 248.0°F
pH
0.01 pH
mV
0.1 mV; 1 mV
Temperature
0.1°C / 0.1 °F
ORDERING INFORMATION
HI 9126-01 (115V) and HI 9126-02 (230V) are supplied with HI 1230B
combination double-junction, gel-filled pH electrode, HI 7662 stainless steel
temperature probe with 1 m (3.3’’) cable, pH 4 & pH 7 buffer solutions (20 mL
sachets), 100 mL plastic beaker, (4) 1.2 AAA rechargeable batteries (inside the
instrument), power adapter, instruction manual and rugged carrying case.
ELECTRODES
Resolution
Accuracy (@20°C)
pH
±0.01 pH
mV
±0.2 mV; ±1 mV
Temperature
±0.4°C / ±0.8°F
HI 9125 pH/mV/temperature and HI 9124 pH/temperature portable
meters are available without backlight and Calibration Check™.
www.hannanorden.com
HI 3230B
ORP electrode, gel filled, PEI body, with platinum sensor,
BNC connector, 1 m (3.3’) cable
SOLUTIONS
HI 70004P pH 4.01 buffer solution, (25) 20 mL sachets
HI 70007P pH 7.01 buffer solution, (25) 20 mL sachets
HI 70010P
pH 10.01 buffer solution, (25) 20 mL sachets
HI 70300L
Electrode storage solution, 500 mL
HI 7061L
Electrode cleaning solution, 500 mL
13
{
Waterproof
and Streamlined
}
Pocket Sized pH Meters
• Extended pH and temperature ranges
• Multi-level display
• Operates on rechargeable batteries
• Low battery detection
• Sensor Check™ electrode status
determination (HI 991003)
• Automatic temperature compensation
for pH readings
• Automatic 1 or 2 point calibration within 2
memorized buffer sets (standard or NIST)
• Auto shut-off
• Waterproof
• Completely redesigned with a smaller
body and base cable connection
• Calibration guides on display
• “HOLD” button to freeze readings on
display for recording purposes
• Combination AISI 316 stainless steel
probes included
• Stability indicator
Waterproof Portables —
Completely Redesigned and
Smaller than Ever!
Redesigned to be smaller and easier to
operate, the probe connection is located on
the base for easy handling and operation.
Both meters measure pH and temperature
while the HI 991003 adds pH-mV and ORP.
AISI 316 stainless steel probe
measures both the primary
measurement and temperature
14
The HI 991003 is equipped with HANNA’s
unique Sensor Check™ feature that allows
the user to determine the electrode status at
any time.
Both the HI 1296D and HI 1297D electrodes
feature a built-in temperature sensor for
automatic temperature compensation (pH).
These AISI 316 stainless steel electrodes
contain a mini pre-amplifier to render
measurements impervious to noise and
electrical interferences.
With Great Products, Come Great Results™
The secondary standard guidelines for water systems set by the EPA states pH should be maintained between 6.5 and 8.5 to
control corrosion and avoid aesthetic or cosmetic concerns. pH is considered a critical variable for determining treatment
options in public water systems operation. Many factors affect pH measurements. Temperature measurement and correction
and the number of calibrated pH standards will improve the quality of the pH measurement. The pH probe together with
instrumentation should be calibrated at a multiple standard calibration points in standardized buffer solution prior to analysis.
Standard method 4500-H+-B.
HANNA manufactures it’s own pH electrodes, meters, buffers and temperature probes.
SPECIFICATIONS
HI 991001
-2.00 to 16.00 pH
pH
Range
mV
—
±825 mV (pH-mV); ±1999 mV (ORP)
—
—
±2 mV
±0.5°C up to 60°C; ±1°C outside
±1°F up to 140°F; ±2°F outside
Temperature
Sensor Check™
HI 1297D
Combination pre-amplified pH/ORP/temp.
probe, DIN connector and 1 m (3.3’) cable
—
HI 7004M
pH 4.01 buffer solution, 250 mL
HI 7007M
pH 7.01 buffer solution, 250 mL
HI 7010M
pH 10.01 buffer solution, 250 mL
HI 70300M Electrode storage solution, 250 mL
±0.02 pH
pH
Accuracy
(@20°C)
1 mV
0.01°C/0.1°F
Temperature
mV
Combination pre-amplified pH/temp.
probe, DIN connector and 1 m (3.3’) cable.
SOLUTIONS
0.01 pH
pH
mV
ELECTRODES
HI 1296D
-5.0 to 105.0°C / 23.0°F to 221.0°F
Temperature
Resolution
HI 991003
Yes
HI 7061M
Electrode cleaning solution, 250 mL
HI 7020M
ORP test solution @200-275 mV, 250 mL
ACCESSORIES
HI 76405
Electrode holder
ORDERING INFORMATION
HI 991001-01 (115V) and HI 991001-02 (230V) are supplied with HI 1296D pH/temperature probe with DIN connector and 1 m (3.3’) cable, calibration &
cleaning solution sachets, (3) 1.2V AAA Ni-MH batteries, 12 Vdc power adapter and instructions.
HI 991003-01 (115V) and HI 991003-02 (230V) are supplied with HI 1297D pH/ORP/temperature probe with DIN connector and 1 m (3.3’) cable, calibration &
cleaning solution sachets, (3) 1.2V AAA Ni-MH batteries, 12 Vdc power adapter and instructions.
www.hannanorden.com
15
{
Titrator, pH Meter, pH Electrode and
Magnetic Stirrer in one compact unit!
}
Total Titratable Alkalinity Titrators
• User-friendly interface
• Dedicated HELP key
• Simple to operate
• Log on demand up to 100 samples
(50 for pH measurement; 50 for titration results)
• GLP feature, to view last calibration
data for pH electrode and pump
• 1, 2 or 3 point calibration
• pH temperature compensation
Total Titratable Very Low Alkalinity Measurement
The HI 84442 is a dedicated mini titrator and pH meter designed for very low levels of alkalinity displayed as 5.0 to
20.00 mg/L (ppm) as CaCO3 or 0.1 to 0.4 meq/L as CaCO3. It utilizes an electrometric titration with a pH electrode to determine
the total titratable alkalinity in water. As titrant is slowly added to the sample solution the pH and temperature are carefully
monitored. The software analyzes the resulting pH curve and determines the volume of titrant required to reach the endpoint
of 4.5 pH (known as bromcresol green alkalinity).
The dispensed titrant volume is used to automatically calculate the water alkalinity, which can be displayed in mg/L CaCO3 or
meq/L. Titrations are conducted using the reagent HI 84442-50.
Total Titratable Low to High Alkalinity Measurement
The HI 84431 is a dedicated mini titrator and pH meter designed for low to high levels of alkalinity. It utilizes an electrometric
titration with a pH electrode to determine the total titratable alkalinity in water. Titrant is slowly added to the sample solution
the pH and temperature are carefully monitored. The software analyzes the resulting pH curve and determines the volume of
titrant required to reach the endpoint. The user can choose either 8.3 pH (known as phenolphthalein alkalinity) or 4.5 pH
(known as bromcresol green alkalinity as endpoints).
The dispensed titrant volume is used to automatically calculate the water alkalinity, which can be displayed in mg/L CaCO3 or
meq/L. Titrations are conducted using the low range reagent HI 84431-50 (10 to 500 mg/L as CaCO3) or the high range
reagent HI84431-51 (400 to 4000 mg/L as CaCO3).
16
With Great Products, Come Great Results™
Peristaltic Pump
These titrators feature a pH meter
which also displays the electrode
condition on the LCD.
Titrant only makes direct contact with the titrant
tubing and not the pump interior virtually eliminating
titrant contamination and ensuring a long pump
operating life.
SPECIFICATIONS
Range
HI 84431 Total Titratable Alkalinity
Total Titratable Alkalinity
(Low/Very Low Range)
mg/L : 10.0 - 500.0 mg/L as CaCO3
meq/L : 0.2 - 10.0 meq/L
Total Titratable Alkalinity (High Range)
mg/L : 400 - 4000 mg/L as CaCO3
meq/L : 8 - 80 meq/L
-2.0 to 16.0 pH / -2.00 to 16.00 pH
Temperature
-20.0 to 120.0 °C (-4.0 to 248.0 °F)
0.01 mg/L; 0.01 meq/L
Total Titratable Alkalinity (High Range)
1 mg/L; 1 meq/L
pH
0.1 pH / 0.01 pH
0.1 °C
Temperature
Accuracy
mg/L : 5.0 - 20.00 mg/L as CaCO3
meq/L : 0.10 - 0.40 meq/L
pH
Total Titratable Alkalinity (Low/Very Low Range)
Resolution
HI 84442 Total Titratable Alkalinity
Titratable Alkalinity/Acidity (Low Range)
5% of reading
Titratable Alkalinity/Acidity (High Range)
3-10 mg/L
± 0.01 pH
pH
±0.4 °C (without probe error)
Temperature
Acid-base titration (total alkalinity)
Titration Method
End point titration: 4.5 pH / 8.3 pH
Titration Principle
End point titration: 4.5 pH
Pump Volume
0.5 mL/min
Stirring Speed
600 rpm
ORDERING INFORMATION
HI 84431-01 (115V) and HI 84431-02 (230V)
are supplied with HI 84431-50 titrant solution low
range (100 mL), HI 84431-51 titrant high range
(100 mL) and HI 84431-55M pump calibration
solution (230 mL).
HI 84442-01 (115V) and HI 84442-02 (230V)
are supplied with HI 84442-50 titrant solution
(100 mL), and HI 84442-55 pump calibration
solution (230 mL).
All meters are supplied with:
HI 1131B pH electrode, HI 7071 filling solution
(30 mL), HI 7662-M temperature probe, HI 7061
cleaning solution, HI 7004M pH 4.01 buffer
solution (230 mL), HI 70083M pH 8.30 buffer
solution (230 mL), HI 7010M pH 10.01 buffer
solution (230 mL), 100 mL beakers (2), tube set
with dispensing tip, medium stir bars (2), 12 Vdc
power adapter, instructions and quick reference
guide.
HI 84442 ACCESSORIES
HI 84442-50
Titrant solution, 100 mL
HI 84442-55
Pump calibration solution, 230 mL
HI 84431 ACCESSORIES
HI 84431-50
Titrant solution for low range,
100 mL
ACCESSORIES
HI 84431-51
Titrant solution for high range,
100 mL
HI 70483M Tube set with cap for titrant bottle
and tip
HI 84431-55M Pump calibration solution,
230 mL
HI 731319
Stir bars, 25 x 7 mm (10)
HI 731342
2000 μL pipette for automatic
dosage
HI 84431-70
Reagents kit for low and high
range (about 150 titrations)
HI 731352
Tips for 2000 μL graduated pipette (4)
HI 84431-71
Reagents kit for low range
(about 150 titrations)
HI 731341
Pipette for automatic dosage
1000 μL
HI 84431-72
Reagents kit for high range
(about 150 titrations)
HI 731351
Tips for 1000 μL graduated pipette
(25)
The titration of water for alkalinity determines it’s ability to resist pH change, mostly due to the bicarbonate/carbonate buffer
but also measures the contributions from hydroxide, phosphates, borate and organic acid salts.
A low alkalinity level indicates that the water is susceptible to pH changes. While a high alkalinity level indicates that the water
will be able to resist pH changes.
Alkalinity can also be used to determine the corrosive capacity of water and water hardness. EPA Method 310.1 or Standard
Methods 2320B.
www.hannanorden.com
17
{
Suitable for titrations of alkalinity, chloride or
calcium hardness using EPA accepted methods.
}
Automatic Titration Systems
Stirrer
The optional stirrer ensures
an effective mixing with a
selectable speed from 100
to 2500 rpm.
Shown with optional extra
burette assembly and stirrer
Versatile Multiparameter Titrators
The HI 901 and HI 902 are full size analytical titrators flexible enough to meet all drinking water standards that require titration
including alkalinity, hardness and chloride. It may also be used for pH measurements. Endpoints may be chosen as fixed mV or pH
or stoichiometrically using first equivalency point detection (with the first or second derivative of titration curve). Ultimate
flexibility permits automation of an existing SOP with user defined titrant concentrations and standardizations.
Both HI 901 and HI 902 can drive two pumps, with the HI 902 incorporating a more advanced system. While the HI 901 can
drive the two pumps separately, HI 902 can also drive them concurrently and perform back titrations. HI 902 can perform more
complex functions with the ability to determine more than one equivalence point.
A Complete Analysis
These instruments perform a complete analysis and all the parameters that a titration requires can be grouped into a method. The
titrators are already supplied with a set of standard methods or you can create your own.
18
With Great Products, Come Great Results™
With HANNA’s Clip-Lock™ Exchangeable Burette System
To avoid conventional titrator problems such as cross contamination of titrants when
exchanging reagents and reconfiguring the titrator for different sample methods HANNA
introduces the Clip-Lock™ exchangeable burette system. Burettes simply slide out for quick
exchanges and detaching the aspiration and dispensing tubes from the titrant bottles is
easy.
Having several prepared burettes on hand will make the HANNA 900 series the fastest and
most versatile titration systems available.
HANNA’s burettes feature a threaded screw connection to prevent leakage and are made of
chemically resistant material to ensure many years of trouble-free operation.
• Clip Lock™ quick burette change
• Dynamic/Linear dosing feature
• Automatic Burette Volume
Recognition
• Fixed endpoint potential or pH
• 320 x 240 pixel LCD w/backlight
• Equivalence point detection
(first and second derivative)
• Precise dosing system (accuracy
under 0.1% of burette volume)
• The results are displayed directly
in the selected units
• Supports up to 10,000 titration
methods (standard and user defined)
• Titration graph can be displayed
on-screen and saved
SPECIFICATIONS
Range
• Reminders for titrant age and
standardization expiration
• Self diagnostic features for
peripheral devices including
pump, valve, burette and stirrer
mV
pH
Temperature
-2000.0 to 2000.0 mV
-2.000 to 20.000 pH
-5.0 to 105.0°C/23 to 221°F/268.2 to 378.2 K
0.1 mV
0.1/0.01/0.001 pH
0.1°C/0.1°F/0.1K
±0.1 mV (@25°C/77°F)
±0.001 pH (@25°C/77°F)
±0.1°C/±0.2°F/±0.1K (excluding probe error)
Resolution
Accuracy
• User customized reports can be
printed, saved to floppy disk or
transferred to PC via RS232
5, 10, and 25 mL
Burette Sizes
Burette Resolution
1/40000
Display Resolution
0.001 mL
±0.1% of full burette volume
Dosing Accuracy
Up to 10,000 methods (standard and user-defined)
Methods
Flow Rate
User-selectable from 0.1 mL/min to 2 x burette volumes/min
pH/mV Measurement
Titrators can also perform direct pH and mV measurements
Manual or automatic (ATC)
Temperature Compensation
Manual or automatic at 1-5 points with 4 buffer sets or custom buffers
pH Calibration
Potentiometric Titrations
Acid-Base (pH or mV-Mode), Redox, Precipitation, Complexometric, Non-Aqueous, Ion-Selective, Argentometric (in mV-mode only)
HI 901 Titration Methods
Fixed mV or pH endpoint detection & first equivalency point detection (with the 1st or 2nd derivatives)
HI 902 Titration Methods
Fixed mV or pH end-point detection & multiple equivalency point detection (with the 1st or 2nd derivatives); back titration
User specified expression of concentration units to suit specific calculation requirements
Measurement Units
Real Time & Stored Graphs
mV-Volume or pH-Volume titration curve, 1st derivative curve or 2nd derivative curve, in pH-mode or mV-mode;
pH/mV values versus time-datalogging results
Up to 100 complete titration and pH/mV logging complete reports
Data Storage:
Disk Drive:
Built-in 3.5" floppy disk drive allows storage and transfer of configurations, preprogrammed methods, custom methods,
titration reports and bitmap graph files
Peripherals
Connections for VGA display, PC-keyboard, parallel printer, RS 232 input, interface for future expansion
GLP Conformity
Instrumentation data storage and printing capabilities
ORDERING INFORMATION
HI 901-01 (115V) and HI 901-02 (230V) is supplied with (1) 25 mL glass burette, (1) burette driver assembly, power adapter and instructions.
HI 902-01 (115V) and HI 902-02 (230V) back titration and multiple endpoint titrators are supplied with (1) 25 mL glass burette, (1) burette driver assembly,
power adapter and instructions.
www.hannanorden.com
19
{
Measures over 20 Drinking Water
Parameters in-house or on-site
}
Multiparameter Photometer
• Log and recall data at a push of a button
• Light blocking cuvette holder
• Back lit LCD for spot testing in low light
• Battery Error Prevention System (BEPS)
ensures low power won’t hinder accuracy
• PC compatible via USB for further analysis
• On-screen tutorial to get started taking
measurements right away
• Powered by 12 Vdc adapter for the lab or
rechargeable batteries for on-site
Ideal for In-house Quality Control
HI 83200 is a multiparameter bench photometer for drinking water analysis. Log individual chemistry analysis from a remote test
site and download and create individual quality reports using Hanna’s Windows® compatible software and a PC connection cable.
Perfect for quality testing to ensure your process is in check.
The HI 83200 can be used remotely utilizing it’s rechargeable batteries or in the lab with the included 12 Vdc adapter.
Save Time and Valuable Benchtop Space
At 235 x 200 x 110 mm (9.20 x 7.87 x 4.33”), the HI 83200 easily fits onto even the busiest benchtop. Since this instrument measures
over 20 drinking water parameters, you’ll have access to weekly measurements to ensure process control.
On-site, Right Now
When battery operated, the HI 83200 becomes a versatile portable laboratory. Often a well water analysis only involves
microbacteriology sampling, but dissolved minerals may be present in the water also (including naturally occurring fluoride ions). The
HI 83200 allows the freedom to perform on site tests for many of these ions and provide a complete report of findings.
20
With Great Products, Come Great Results™
{
Perfect for quality testing to
ensure your process is in check.
}
Cuvette Holder with Door
The HI 83200’s cuvette cover aids in stopping
stray light from effecting measurements.
Drinking Water Parameters
Alkalinity
Chlorine
Color
Fluoride
Manganese
Ozone
Silica
Aluminum
Chlorine Dioxide
Copper
Iron
Nitrate
pH
Silver
Calcium
Chromium
DO
Magnesium
Nitrite
Phosphate
Zinc
Measures 45 parameters in all!
Setup Button
HELP Button
On-screen Tutorial
Change preferences via the setup button.
Screen specific help at the touch of a button.
With the tutorial function enabled, short
guides relating to current operation are
displayed.
Method Selection
Save and Recall Logged Data at the Touch of a Button
Easily select parameters via the Method
button.
Simply touching the LOG button users can save readings into memory. Pressing the RCL
button brings back logged information for viewing on-screen. Logged information can be
transferred to a PC using the HI 92000 Windows® compatible software for further study or
printing formal reports.
www.hannanorden.com
21
Monthly Delivery Program for Reagents
Individually Packaged, HANNA Reagents Delivered When You Need Them.
When you take advantage of our Monthly Reagent Delivery Program, HANNA can automatically ship your required reagents to
your lab every month! Best of all, you’ll receive your reagents at a discounted rate depending on your payment schedule. Plan
your payments annually, semi-annually or quarterly to ensure you’ll never be without reagents for critical drinking water
quality tests.
Contact your local HANNA sales representative to take the hassle out of ordering reagents and have quality reagents delivered
to your lab on time every month.
HI 83200 Reagent List
TEST
Aluminum
Alkalinity
Calcium
REAGENT
ORDERING CODE
TEST
REAGENT
ORDERING CODE
TEST
REAGENT
ORDERING CODE
HI 93712-01
Fluoride
HI 93729-01
Ozone
HI 93757-01
HI 93755-01
Hardness (calcium)
HI 93720-01
pH
HI 93710-01
Hardness (magnesium)
HI 93719-01
Phosphate LR
HI 93713-01
HI 937521-01**
Chlorine Dioxide
HI 93738-01
Iron LR
HI 93746-01**
Phosphorus
HI 93706-01
Chlorine*, Free
HI 93701-01
Magnesium
HI 937520-01**
Potassium HR
HI 93750-01
Chlorine*, Total
HI 93711-01
Manganese LR
HI 93748-01**
Potassium MR
HI 93750-01
Chromium VI LR
HI 93749-01
Nitrate
HI 93728-01
Potassium LR
HI 93750-01
—
Nitrite HR
HI 93708-01
Silica
HI 93705-01
Copper LR
HI 95747-01
Nitrite LR
HI 93707-01
Silver
HI 93737-01**
Cyanide
HI 93714-01
Oxygen, Dissolved (DO)
HI 93732-01
Zinc
Color
HI 93731-01
All reagents with -01 final code are for 100 tests unless noted otherwise. * For Chlorine, liquid reagents are available. ** Reagents for 50 tests
Some reagents are available for 300 tests, contact your local HANNA sales office for more information
22
With Great Products, Come Great Results™
Data Management
Data can be managed using the HI 92000
Windows® compatible software.
SPECIFICATIONS
4 tungsten lamps with narrow band interference filters at 420/525/575/610 nm
Light Source
4 Silicon photocells
Light Detector
TEST
RANGE
TEST
RANGE
RANGE
Aluminum
0.00 to 1.00 mg/L
Alkalinity
0 to 500 mg/L
Iron LR
0 to 400 μg/L
Phosphate LR
Calcium
0 to 400 mg/L
Magnesium
0 to 150 mg/L
Phosphorus
0.0 to 15.0 mg/L
0 to 300 μg/L
Potassium MR
10 to 100 mg/L
Fluoride
Chlorine Dioxide
0.00 to 2.00 mg/L
Manganese LR
Chlorine*, Free
0.00 to 2.50 mg/L
Nitrate
Chlorine*, Total
0.00 to 3.50 mg/L
Chromium VI LR
Color
Copper LR
0.00 to 2.00 mg/L
TEST
6.5 to 8.5 pH
pH
0.00 to 2.50 mg/L
0.0 to 30.0 mg/L
Silica
0.00 to 2.00 mg/L
Nitrite HR
0 to 150 mg/L
Silver
0.000 to 1.000 mg/L
0 to 300 μg/L
Nitrite LR
0.00 to 0.35 mg/L
0 to 500 PCU
Oxygen, Dissolved (DO)
0 to 1000 μg/L
0.00 to 2.00 mg/L
Ozone
ACCESSORIES
HI 83200-01 (115V) and HI 83200-02 (230V)
are supplied with (4) sample cuvettes, sample
preparation kit, cuvette cleaning cloth, scissors,
12 Vdc adapter and instructions.
HI 93703-50 Cuvette cleaning solution, 230 mL
www.hannanorden.com
0.00 to 3.00 mg/L
0.0 to 10.0 mg/L
ORDERING INFORMATION
HI 83200C-01 (115V) and HI 83200C-02 (230V)
are supplied with a rugged carrying case, (4)
sample cuvettes, sample preparation kit, cuvette
cleaning cloth, scissors, 12 Vdc adapter and
instructions.
Zinc
HI 721310
9V battery (10)
HI 731318
Cuvette cleaning cloths (4)
HI 731321
Glass cuvettes (4)
HI 731325N New caps for cuvette (4)
HI 740034
Caps for 100 mL beaker (6)
HI 740036
100 mL plastic beakers (6)
HI 740038
60 mL glass bottle and stopper
HI 740142
1 mL graduated syringe
HI 740143
1 mL graduated syringes (6)
HI 740144
Pipette tips (6)
HI 740157
Plastic pipettes (20)
HI 740220
25 mL glass cylinders with cap (2)
HI 740223
170 mL plastic beaker
HI 740224
170 mL plastic beakers (12)
HI 740225
60 mL graduated syringe
HI 740226
5 mL graduated syringe
HI 740227
Filter assembly
HI 740228
Filter discs (25)
HI 740229
100 mL Polypropylene cylinder
HI 740230
Demineralized water, 230 mL
HI 92000
Windows® Compatible Software
HI 920010
PC connection cable
HI 93703-54 Dried resin, 100 g
HI 93703-55 Activated Carbon (50)
23
{
}
Perfect for
On-Site Tests
Free and Total Chlorine Photometer
• CAL CHECK™ validation
• Log up to 99 records
• RS232 PC compatible
• Perfect for on-site tests
• Expandable with iButton® TAGs
• Auto shut-off
• Powered by a single 9V battery
Shown with optional TAGs
Portable Kit for Routine Spot Analysis
The HI 96711 measures free and total chlorine with quick traceability of each measured sample.
The sample traceability system allows users to collect and manage data in a very simple and error free way. All measurements
can be quickly organized by time or by sample. The check function allows the user to validate the good performance of the
instrument at any time.
The HI 96711 can log up to 99 measurements in internal memory. Logs can be transferred to a PC via HANNA’s HI 92000
software (optional) for permanent records and verification.
CAL CHECK™ Calibration Validation
With HANNA’s exclusive CAL CHECK™ validation function users are able to verify the
performance of the instrument at any time. Taking just a few short steps, the
validation procedure is user friendly and ensures that the meter is properly calibrated.
24
Peace of mind.
With Great Products, Come Great Results™
{
A Revolution in Organized
Data Management
SPECIFICATIONS
}
HI 96711
Free Chlorine
0.00 to 5.00 mg/L
Total Chlorine
0.00 to 5.00 mg/L
Range
Resolution
0.01 mg/L 0.00 to 3.50 mg/L; 0.10 mg/L above 3.50 mg/L
±0.02 mg/L to 1.00 mg/L
Precision
Light Source
Tungsten lamp with narrow band interference filter 525 nm
Silicon photocell
Light Detector
Method
Adaptation of USEPA 330.5 Method and Standard Methods 4500-Cl G
ORDERING INFORMATION
HI 93711-01 Reagents for 100 tests
(Total Chlorine)
HI 96711 is supplied with (2) sample cuvettes
with caps, (10) reagent powder packets, (4)
batteries and instructions.
HI 93711-03 Reagents for 300 tests
(Total Chlorine)
HI 96711C is supplied with (2) sample cuvettes
with caps, (3) CAL CHECK™ cuvettes, (10) reagent
powder packets, cuvette cleaning cloth, (4)
batteries, scissors and instructions in a hard
carrying case.
SOLUTIONS
HI 95701-11 CAL CHECKTM standard cuvettes
for Free Chlorine
HI 95711-11 CAL CHECKTM standard cuvettes
for Total Chlorine
ACCESSORIES
HI 920005 iButton® TAGs (5)
HI 92000
Software for PC connection,
Windows® compatible
HI 93703-50 Cuvette cleaning solution, 250 mL
HI 920011
Serial cable for PC connection
REAGENTS
HI 731318
Cuvette cleaning cloth (4)
HI 93701-01 Reagents for 100 tests
(Free Chlorine)
HI 731331
Measuring cuvettes (4)
HI 731335
Cuvette caps (4)
iButton® TAG
Fast Tracker™ Tag
Identification System (T.I.S.)
HANNA’s exclusive Fast Tracker™ —
Tag Identification System simplifies
test logging while retaining the
management versatility users need to
search, filter and export data. The
system, ideal for on-site spot checks,
helps verify that samples have truly
been taken at pre-established
locations during safety audits and
inspections.
HI 93701-03 Reagents for 300 tests
(Free Chlorine)
www.hannanorden.com
25
{
Water-resistant
}
Single Parameter Photometers
• Large, dual-level LCD
• Water-resistant
• Accuracy verification
• User calibration
• Certified calibration &
verification standards
• Secondary standards for
calibration and verification
• Custom ranges
• Long battery life
• Auto shut-off
Photometers Designed for Both Laboratory and Field Use
HANNA’s of single parameter photometers for drinking water applications feature water resistance, a large dual-level LCD, an
advanced optical system and HANNA's exclusive CAL CHECK™ validation function. With the powerful CAL CHECKTM validation
function, users are able to validate performance of the instrument at any time.
The instrument is water resistant and the light source and filter units are protected from dust or dirt by a transparent cup. This
makes the instrument ideal for field applications. Display messages aid the user in routine operation. The meter has an autoshut off feature that will turn off the instrument after 10 minutes of non use in measurement mode or after 1 hour if left in
calibration mode.
These meters also use an exclusive positive-locking system
to ensure that the cuvette is in the same position every time
it is placed into the measurement cell. It is designed to fit a
cuvette with a larger opening making it easier to add both
sample and reagents. The cuvette is made from special
optical glass to obtain best results.
HI 731318
SOLUTIONS
GENERAL SPECIFICATIONS
Environment
0 to 50°C (32 to 122°F); RH max 95% non-condensing
Power Supply
(1) 9V battery
Auto-off
26
HI 731331
After 10 minutes of non-use in measuring mode
After 1 hour of non-use in calibration mode with last
reading reminder
HI 93703-50
Cuvette cleaning solution, 250 mL
ACCESSORIES
HI 731318
Cuvette cleaning cloth (4)
HI 731331
Measuring cuvettes (4)
HI 731335
Cuvette caps (4)
With Great Products, Come Great Results™
Free/Total Chlorine Photometer
Anionic Detergents Photometer
The HI 96724 meter measures the free and total chlorine
(Cl2) content in water samples in the 0.00 to 5.00 mg/L
(ppm) range. The method is an adaptation of the USEPA
Method 330.5 for wastewater and Standard Method 4500-Cl G
for drinking water.
Detergents are produced in large quantities and are widely
used in many applications. Due to their common use,
detergents are introduced into the water supply through
domestic and industrial drains.
SPECIFICATIONS
SPECIFICATIONS
HI 96724
Free Cl2
0.00 to 5.00 mg/L
Total Cl2
0.00 to 5.00 mg/L
Range
0.00 to 3.50 mg/L (as LAS, Linear Alkylbenzene Sulfonate)
0.01 mg/L
Resolution
Range
±0.04 mg/L @ 1.00 mg/L
Precision
0.01 mg/L (0.10 mg/L over 3.50 mg/L)
Resolution
HI 96769
Tungsten lamp
Light Source
±0.03 mg/L to 1.00 mg/L
Precision
Silicon photocell with narrow band
interference filter @ 525 nm
Light Detector
Method
Adaptation of the USEPA method 330.5 and Standard
Method 4500-Cl G.
Method
Silicon photocell with narrow band interference
filter @ 610 nm
Light Detector
Tungsten lamp
Light Source
Adaptation of the USEPA method 425.1 for drinking waters,
surface waters, domestic and industrial wastes
and Standard Methods, 20th edition, 5540C,
Anionic Surfactants by MBAS.
ORDERING INFORMATION
ORDERING INFORMATION
HI 96724 is supplied with (2) sample cuvettes with caps, 9V battery
and instructions.
HI 96769 is supplied with (2) sample cuvettes with caps, 9V battery and
instructions.
HI 96724C is supplied with CAL CHECK™ standard cuvettes, (2) sample
cuvettes with caps, 9V battery, cuvette cleaning cloth, scissors and
instructions in a hard carrying case.
HI 96769C is supplied with CAL CHECK™ standard cuvettes, (2) sample cuvettes
with caps, (1) long glass vial (25 mL) with cap, (3) plastic pipettes, 9V battery,
cuvette cleaning cloth and instruction manual in a hard carrying case.
REAGENTS AND STANDARDS
REAGENTS AND STANDARDS
HI 93701-T*
Liquid reagents for 300 tests of Total Chlorine
HI 95769-01
Reagent kit for 40 tests
HI 93701-F
Liquid reagents for 300 tests of Free Chlorine
HI 95769-11
CAL CHECK™ Standard Cuvettes (1 set)
HI 93711-D3
DPD liquid reagent for 600 tests of Total Chlorine
HI 95724-11
CAL CHECK™ standard cuvettes (1 set)
photometers
are available as a KIT
HANNA
Just choose the “C” version
HI 96715C kit version shown.
Copper, Low Range Photometer
The HI 96747 measures the free dissolved Copper (Cu) content in water samples in the 0.000 to 1.500 mg/L (ppm) range.
SPECIFICATIONS
Range
Resolution
Precision
Light Source
Light Detector
Method
HI 96747
0.000 to 1.500 mg/L
0.001 mg/L for measurement; 0.01 mg/L for calibration
and validation
±0.015 mg/L to 0.750 mg/L
ORDERING INFORMATION
HI 96747 is supplied with (2) sample cuvettes with caps, 9V battery
and instructions.
HI 96747C is supplied with CAL CHECK™ standard cuvettes and reagents, (2)
sample cuvettes with caps, 9V battery, cuvette cleaning cloth, scissors and
instructions in a hard carrying case.
Tungsten lamp
Silicon photocell with narrow band interference
filter @ 560 nm
Bicinchoninate method.
www.hannanorden.com
REAGENTS AND STANDARDS
HI 95747-11
CAL CHECK™ Standard Cuvettes (1 set)
HI 95747-01
Reagents for 100 tests
HI 95747-03
Reagents for 300 tests
27
Fluoride, Low Range Photometer
A high concentration of fluoride can be harmful, so its presence needs to be monitored. HANNA offers the HI 96729, including
an automatic 2000 μL automatic pipette.
One of the most important interfering elements for fluoride is chlorine, present in some applications such as drinking waters.
HANNA suggests using the HI 93703-53 liquid reagent with dropper to remove chlorine interference. This reagent is very
quick and practical to use, just add a drop to every 2 mg/L (ppm) of chlorine to eliminate its interference.
SPECIFICATIONS
Range
HI 96729
0.00 to 2.00 mg/L (ppm)
0.01 mg/L (ppm)
Resolution
Precision
±0.03 mg/L to 1.00 mg/L (ppm)
Tungsten lamp
Light Source
Light Detector
Method
Silicon photocell with narrow band interference
filter @ 575nm
Adaptation of the USEPA method 340.1 and Standard
Methods for the Examination of Water and Wastewater,
20th edition, SPANDS method.
ORDERING INFORMATION
HI 96729 is supplied with (2) sample cuvettes with caps, 9V battery and
instructions.
HI 96729C is supplied with CAL CHECK™ standard cuvettes, (2) sample
cuvettes with caps, (1) 2000 μL automatic pipette with cap, (1) pipette tip,
9V battery, cuvette cleaning cloth and instruction manual in a hard carrying case.
REAGENTS AND STANDARDS
HI 95729-11
CAL CHECK™ Standard Cuvettes (1 set)
HI 93703-53
Chlorine remover
HI 93729-01
Reagents for 100 tests
HI 93729-03
Reagents for 300 tests
Nitrite, Low Range Photometer
The HI 96707 meter measures the Nitrogen-Nitrite (NO2--N) content in the 0.000 to 0.600 mg/L (ppm) range, in drinking,
surface and saline water samples and in domestic and industrial wastes. The method is an adaptation of an EPA approved method.
SPECIFICATIONS
Range
HI 96707
0.000 to 0.600 mg/L (ppm) (as NO2--N)
0.001 mg/L (ppm)
Resolution
Precision
±0.001 mg/L to 0.100 mg/L (ppm)
Tungsten lamp
Light Source
Light Detector
Method
Silicon photocell with narrow band interference
filter @ 525 nm
Adaptation of an USEPA approved method 354.1.
ORDERING INFORMATION
HI 96707 is supplied with (2) sample cuvettes with caps, 9V battery and
instructions.
HI 96707C is supplied with CAL CHECK™ standard cuvettes, (2) sample
cuvets with caps, 9V battery, cuvette cleaning cloth, scissors and instruction
manual in a hard carrying case.
REAGENTS AND STANDARDS
HI 95707-11
CAL CHECK™ Standard Cuvettes (1 set)
HI 93707-01
Reagents for 100 tests
HI 93707-03
Reagents for 300 tests
Silica Photometer
The HI 96770 meter measures the molybdate reactive silica (SiO2) content in water samples in the 0 to 200 mg/L (ppm) range.
The method is an adaptation of the USEPA METHOD 370.1 for drinking, surface and saline waters, domestic and industrial
wastes and Standard Method 4500-SiO2 C.
SPECIFICATIONS
Range
Resolution
Precision
Light Source
Light Detector
Method
28
HI 96770
0 to 200 mg/L (ppm) (SiO2)
1 mg/L (ppm)
±5 mg/L @ 100 mg/L (ppm)
Light Emitting Diode
Silicon photocell with narrow band interference
filter @ 466 nm
Adaptation of the USEPA METHOD 370.1 for drinking,
surface and saline waters, domestic and industrial wastes
and Standard Method 4500-SiO2 C.
ORDERING INFORMATION
HI 96770 is supplied with (2) sample cuvettes with caps, 9V battery and
instructions.
HI 96770C is supplied with CAL CHECK™ standard cuvets, (2) sample
cuvettes with caps, 9V battery, cuvette cleaning cloth, scissors and
instruction manual in a hard carrying case.
REAGENTS AND STANDARDS
HI 96770-11
CAL CHECK™ Standard Cuvettes (1 set)
HI 96770-01
Reagents for 100 high range tests
HI 96770-03
Reagents for 300 high range tests
With Great Products, Come Great Results™
{
Speedsafe™
}
Magnetic Stirrers
• Safety with Speedsafe™
Speedsafe limits the
maximum speed to 1000 rpm even
if the load is suddenly removed.
• Chemical Resistance
The ABS housing of the HI 180
resists most harmful chemicals in
the lab.
HI 180
• Compact Size
The compact size of these stirrers
allows users to maximize bench
space for efficiency and safety.
HI 301N
Advanced Features and Stainless Steel Cover
Compact Size and ABS plastic Cover
HI 301N and HI 311N are heavy-duty stirrers that offer dual
range precision. HI 310N can stir up to 2.5 liters (0.66
gallons) of liquid and HI 311N can stir up to 5.0 liters (1.3
gallons).
HANNA HI 180 series are compact, lightweight stirrers with a
rounded, dynamic design.
Similar to the "ZOOM" function of a microscope, these
stirrers allow access to two separate stirring ranges. In each
range, the speed can be fine tuned for exacting accuracy.
In addition, the HI 311N also has an automatic feedback
feature. The motor is electronically controlled to maintain
the chosen speed as the load changes. If the viscosity or
level (fluid weight) increases or decreases, the circuitry will
adjust the output power to keep the speed constant.
SPECIFICATIONS
Maximum Stirring Capacity
Speed
Range
Low
High
Auto-Feedback
Power Supply
Installation Category
Cover Material
HI 311N
HI 301N
HI 180
5 liters
2.5 liters
1 liter
100 to 500 rpm
100 rpm
100 to 800/1000 rpm
Standard
1000 rpm
—
Available in nine colors, light yellow, light sea-green, light
blue, yellow, green, dark blue, red, grey and ivory, several
HI 180 stirrers can be placed on a laboratory bench with their
colors helping to identify the different samples.
ORDERING INFORMATION
HI 301N and HI 311N are supplied with magnetic stir bar and instructions
HI 301N-1
HI 301N-2
HI 311N-1
HI 311N-2
Magnetic stirrer, stainless steel cover, 110/115 Vac
Magnetic stirrer, stainless steel cover, 220/240 Vac
Magnetic stirrer, stainless steel cover, 110/115 Vac
Magnetic stirrer, stainless steel cover, 220/240 Vac
HI 180 series are supplied complete with micro stir bar and instructions.
HI 180 A-1
HI 180 A-2
Light yellow mini-stirrer, 110/115 Vac
Light yellow mini-stirrer, 220/240 Vac
Other colors are available, just replace the letter A with one of the
following letters: B Light sea-green, C Light blue, D Yellow, E Green, F Blue, G Red,
H Grey, I Ivory
110/115 Vac or 230/240 Vac, 50/60 Hz
ACCESSORIES
II
AISI 316 stainless steel
www.hannanorden.com
ABS plastic
HI 731320
Magnetic stir bar (10) for HI 311N and HI 301N
HI 731319
Magnetic stir bar (10) for HI 180 series
29
{
±0.3°C Accuracy
and CAL CHECK™
}
Temperature Monitor
• Magnetic backing
• Food grade stainless steel
thermistor probe on
1 m (3.3’) cable
• Fast response
• CAL CHECK™ verification
• Low battery warning
• Small and lightweight
Perfect for Refrigerator and Incubator Monitoring
Water testing laboratories require constant monitoring of refrigerators and incubators for compliance to standard operations.
The Hanna HI 147 Checkfridge™ C is the ideal thermometer when you need accurate, reliable internal temperature readings
while monitoring from outside. The HI 147 temperature monitor has a magnetic backing that provides flexibility and ease of
location for convenient relocation if required. The device incorporates a unique CAL CHECK™ feature which allows the user to
calibrate the thermometer internally. A low battery warning "ERR" message completes HI 147's rich features.
SPECIFICATIONS
Range
Resolution
Accuracy
Calibration Check
Probe
Battery Type / Life
30
HI 147-00 Checkfridge™ C
HI 147-01 Checkfridge™ F
-50.0 to 150.0°C
-58.0 to 302.0°F
0.1°C
0.1°F (-58.0 to 199.9°F)
1°F (200 to 302°F)
±0.3°C (-20 to 90°C); ±0.5°C (outside)
±0.6°F (-4 to 194°F); ±1°F (outside)
ORDERING INFORMATION
HI 147-00 (Checkfridge™ C) is supplied complete with
battery and instructions
HI 147-01 (Checkfridge™ F) is supplied complete with
battery and instructions
manual, through switch
stainless steel, general purpose; 40 x DIA 5 mm (1.6 x DIA 0.2’’); 1 m (3.3’) cable
(1) 1.5V AAA / approx. 3 years of use
With Great Products, Come Great Results™
pH and ORP Electrodes
BNC Connector
PARAMETER
CODE
Description
Reference
Junction / Flow Rate
Electrolyte
Max Pressure
Range
Tip / Shape
Body Material
Cable
Connector
{
pH
pH
ORP
HI 1230B
HI 1131B
HI 3230B
Combination pH Electrode
Refillable, combination pH Electrode
Refillable, combination pH Electrode
Double, Ag/AgCl
Single, Ag/AgCl
Single, Ag/AgCl
Ceramic, single / 15-20 μL/hr
Ceramic, single / 15-20 μL/hr
Ceramic, single / 15-20 μL/hr
Gel
KCL 3.5M + AgCl
Gel
2 bar
0.1 bar
2 bar
pH: 0 to 13
Temp: 0 to 80°C (32 to 176°F)
pH: 0 to 13
Temp: -5 to 100°C (23 to 212°F)
ORP: 0±2000 mV
Temp: 0 to 80°C (32 to 176°F)
Spheric (7.5 mm DIA)
Spheric (9.5 mm DIA)
Platinum Pin
PES (polyethersulfone)
Glass
PES (polyethersulfone)
1 m coaxial (3.3’)
1 m coaxial (3.3’)
1 m coaxial (3.3’)
BNC
BNC
BNC
Electrodes Designed and
Manufactured by HANNA
www.hannanorden.com
}
31
pH and ORP Solutions
pH Technical Solutions (±0.01 pH)
for Each Point of the pH Scale.
These solutions are dedicated to those
applications that require extremely accurate
(±0.01 pH accuracy) pH monitoring.
HANNA Combo Kits
Use our combination kits for easy ordering.
ORP Standard Solutions
ORP standard solutions allows users to test the
precision of ORP electrodes. For example, by
immersing the electrode in HI 7020 solution,
readings should fall within the 200 to 275 mV
range (@20°C/68°F).
If the reading is outside the indicated interval,
clean and condition your ORP electrode in
HANNA pretreatment solution. Use HI 7092 for
oxidizing or HI 7091 for reducing pretreatment.
pH Technical Solutions
SACHETS
BOTTLES
Code
pH Value
Package
@25°C
Code
pH Value
Package
@25°C
HI 5004
4.01
(1) 500 mL
HI 50004-01
4.01
(10) 20 mL
HI 5004-01
4.01
(1) 1 L
HI 50004-02
4.01
(25) 20 mL
HI 5007
7.01
(1) 500 mL
HI 50007-01
7.01
(10) 20 mL
HI 5007-01
7.01
(1) 1 L
HI 50007-02
7.01
(25) 20 mL
HI 5010
10.01
(1) 500 mL
HI 50010-01
10.01
(10) 20 mL
HI 5010-01
10.01
(1) 1 L
HI 50010-02
10.01
(25) 20 mL
Combination pH Buffer Kits
Code
Solutions (pH Value @25°C)
Bottle
HI 54710
pH 4.01, pH 7.01, pH 10.01
(3) 500 mL
HI 54710-10
pH 4.01, pH 7.01, pH 10.01, HI 70300L
(4) 500 mL
HI 54710-11
pH 4.01, pH 7.01, pH 10.01, HI 70300L, HI 7061L
(5) 500 mL
HI 54710-12
pH 4.01, pH 7.01, pH 10.01, HI 70300L, HI 7061L, HI 7071L
(6) 500 mL
HI 54710-13
pH 4.01, pH 7.01, pH 10.01, HI 70300L, HI 7061L, HI 7072L
(6) 500 mL
ORP Test and Pretreatment Solutions
32
Code
Description
Package
HI 7020L
ORP Test Solution at 200/275 mV (@20°C)
500 mL bottle
HI 7020M
ORP Test Solution at 200/275 mV (@20°C)
250 mL bottle
HI 7021L
ORP Test Solution at 240 mV (@20°C)
500 mL bottle
HI 7021M
ORP Test Solution at 240 mV (@20°C)
250 mL bottle
HI 7022L
ORP Test Solution at 470 mV (@20°C)
500 mL bottle
HI 7022M
ORP Test Solution at 470 mV (@20°C)
250 mL bottle
HI 7091L
Reducing Pretreatment Solution
500 mL bottle
HI 7091M
Reducing Pretreatment Solution
250 mL bottle
HI 7092L
Oxidizing Pretreatment Solution
500 mL bottle
HI 7092M
Oxidizing Pretreatment Solution
250 mL bottle
With Great Products, Come Great Results™
pH and ORP Solutions
pH and ORP Electrode Refill
Solutions
pH and ORP Electrode Refill Solutions
Code
Description
Package
The electrolyte level in refillable electrodes
should be checked before performing any
measurement. If the level is low, refill with the
proper electrolyte solution to ensure the
correct electrode performance.
HI 7071
Electrolyte Solution, 3.5M KCl + AgCl
(4) 30 mL bottle
HI 7071L
Electrolyte Solution, 3.5M KCl + AgCl
500 mL bottle
Electrode Storage Solutions for
pH Electrodes
To minimize junction clogging and ensure fast
response time, always keep the glass bulb and
the junction of your pH electrode moist. Store the
electrode with a few drops of HI 70300 storage or
pH 7 buffer solution in the protective cap.
Storage Solutions for pH Electrodes
Code
Description
Package
HI 70300L
Electrode Storage Solution
500 mL bottle
HI 70300M
Electrode Storage Solution
250 mL bottle
pH Electrode Cleaning Solutions for
General Use
General Cleaning
Clean the liquid junction of your electrodes
once a day or at least once a week to prevent
junction clogging and to maintain accuracy.
Immerse the electrode in the proper cleaning
solution for at least 15-20 minutes.
Code
Application
Package
HI 70000P
Rinsing
(25) 20 mL sachet
HI 7061L
General Purpose
500 mL bottle
HI 7061M
General Purpose
250 mL bottle
{
www.hannanorden.com
Practical, Safe and
Ready to Use Solutions
}
33
ISE Electrodes
Use in conjunction
with HI 5315
Reference Electrode
Use in conjunction
with HI 5315
Reference Electrode
PARAMETER
CHLORIDE
Use in conjunction
with HI 5315
Reference Electrode
FLUORIDE
Use in conjunction
with HI 5315
Reference Electrode
SILVER/SULFIDE
NITRATE
CODE
HI 4007
HI 4107
HI 4010
HI 4110
HI 4013
HI 4113
HI 4015
HI 4115
Type
Solid-state;
Half-cell
Solid-state;
Combination
Solid-state;
Half-cell
Solid-state;
Combination
Polymer Membrane;
Half-cell
Polymer Membrane;
Combination
Solid-state;
Half-cell
Solid-state;
Combination
1M to 5X 10-5M
35000 to 1.8 ppm
1M to 1X 10-6M
Sat. to 0.02 ppm
1.0M to 1X 10-5M
6200 to .62 ppm
Ag+ 1.0M to 1X 10-6M
107900 to 0.11 ppm
S= 1.0M to 1X 10-7M
32100 to 0.003 ppm
Optimum pH
Range
2 to 11
5 to 8
3.0 to 8
Ag+ 2 to 8
S= 12 to 14
Temperature
Range
0 to 80°C
0 to 80°C
0 to 40°C
0 to 80°C
Approximate
Slope
-57
-56
-56
-56 Ag+ / -28 S=
12 mm
12 mm
12 mm
12 mm
120 mm
120 mm
120 mm
120 mm
Measurement
Range
Body O.D.
Insertion Length
Body Material
Cable
Connector
Fill Solution*
Epoxy
PEI
Epoxy
PEI/Epoxy
PVC
PEI/PVC
Epoxy
PEI
1 m coaxial
1 m coaxial
1 m coaxial
1 m coaxial
BNC
BNC
BNC
BNC
HI 7072
HI 7075
HI 7082
HI 7072
*not included
Solid State Electrodes are available as
both single half-cells or as combination
electrodes complete with reference
electrode. These electrodes incorporate a
solid sensing surface made of compressed
silver halides, or solid crystalline material.
HANNA’s offering includes sensors for the
determination of chloride, fluoride
and silver ions. Solid body construction is
rugged for long life.
34
Liquid Membrane Electrodes are
available as single half-cells or as
combination electrodes complete with
reference electrode. The sensing
surfaces of these electrodes are
comprised of a homogeneous polymer
matrix containing organic ionexchangers
selective
for
the
determined ion. These sensors
incorporate
easily
replaceable
membrane modules and are available
for measurements of nitrate.
Combination Electrodes include a sensor
and reference electrode in a single electrode
body. Our combination ion selective
electrodes provide the same selectivity and
response as our ISE half-cells, but include our
superior double junction reference into the
same electrode body. Combination solid state
electrodes have a built in solid state sensor
and quick refillable reference electrode. Our
liquid membrane and fluoride combination
electrodes have replaceable module
construction and the HANNA double junction
reference stability.
With Great Products, Come Great Results™
ISE Solutions
HANNA Silver-free Reference Fill Solutions
Specifically for ISE Electrodes
HANNA ISE Standards
CODE
Description
Size
HI 4010-01
0.1 M fluoride std.
500 mL
HI 4010-02
100 ppm fluoride std.
500 mL
HI 4010-03
1000 ppm fluoride std.
500 mL
HI 4010-10
10 ppm fluoride std. premixed with TISAB II
500 mL
HI 4010-11
1 ppm fluoride std. premixed with TISAB II
500 mL
HI 4010-12
2 ppm fluoride std. premixed with TISAB II
HI 4010-30
(4) 1 ppm, (4) 10 ppm fluoride std. with (4) TISAB II 500 mL
HI 4013-01
0.1 M nitrate std.
500 mL
HI 4013-02
100 ppm nitrate std.
500 mL
HI 4013-03
1000 ppm nitrate std.
500 mL
Recommended for our Combination ISE Electrodes and the HANNA
HI 5315 reference electrode. Reference electrodes should be topped
off daily with the correct filling solution for optimum measurement
performance. These solutions are silver free to eliminate silver
precipitates found with standard electrolytes.
Code
Description
Size
HI 7072
Electrolyte solution, 1 M KNO3
(4) 30 mL bottles
HI 7075
Electrolyte solution with KNO3 and KCl
(4) 30 mL bottles
HI 7078
Electrolyte solution, (NH4)2SO4
(4) 30 mL bottles
HI 7082
Electrolyte solution, 3.5M KCl
(4) 30 mL bottles
500 mL
HANNA Accessories
Ionic Strength Adjusters (ISA)
HANNA Ionic Strength Adjusters (ISA) are formulated to provide a
constant ionic strength in sample and standards alike, thus
permitting concentration rather than activity measurements to be
made. In some cases ISA's adjust pH and eliminate matrix effects.
HANNA ISE replacement parts and accessories keep your
measurements fast and accurate.
Code
Description
HI 4000-50
Liquid membrane sensor handle
HI 4000-70
Halide polishing strip
Code
Description
Size
HI 4110-51
Fluoride module for combination electrode
HI 4010-00
TISAB II (for fluoride)
500 mL
HI 4013-53
Nitrate module 3 pack for half-cell
HI 4010-06
TISAB III concentrate (for fluoride)
500 mL
HI 4113-53
Nitrate module 3 pack for combination
HI 4013-06
Nitrate interferent suppressant ISA
500 mL
HI 740155P
Capillary pipettes (20)
PARAMETER
REFERENCE
CODE
HI 5315
Temperature Range
0 to 80°C
Approximate Slope
Body O.D.
Insertion Length
Body Material
Cable
Connector
N/A
12 mm
120 mm
PEI
1 m coaxial
Reference Electrodes are used to provide a stable voltage and electrolytic contact to permit
a voltage gradient to be measured across a measurement membrane such as an ISE. HANNA
has designed an easy to use, double junction, quick fill, sleeve style reference electrode with a
cone style junction to work with the ion selective electrode family of sensors.
The HI 5315 is a silver/silver chloride electrode half-cell with a permanent gel filled internal cell.
The outer fill solution is easily replaceable and serves as a buffer zone between the internal
chloride ion containing gel and the sample solution. HANNA offers a complete line of silver-free
fill solutions to optimize your ion measurement. A fast responding liquid junction, excellent
reproducibility and ease of use will mark this reference as your “best” in the lab.
Banana
www.hannanorden.com
35
Worldwide Contacts
Africa
Egypt
instruments® Egypt Ltd.
P: (02) 2758683 / 6717098
F: (02) 2758683
E: egypt@hannainst.com
HANNA
Mauritius
instruments® Mauritius Ltd.
P: (230) 508.1555
F: (230) 208.6386
E: mauritius@hannainst.com
HANNA
Morocco
instruments® Morocco S.a.r.l.
P: +212 (0)28 23 35 30
+212 (0)28 23 35 06
F: +212 (0)28 23 35 17
E: morocco@hannainst.com
HANNA
Americas
Asia
Europe
Argentina
China
Belgium
Poland
instruments® Argentina s.a.
P: (11) 4308.1905 / 4308.4807
F: (11) 4308.1904
E: argentina@hannainst.com
Beijing HANNA instruments®
P: (10) 88570068
F: (10) 88570060
E: china@hannainst.com
HANNA
instruments® BVBA
P: (03) 710.9340
F: (03) 710.9359
E: belgium@hannainst.com
HANNA
Brazil
India
France
Portugal
HANNA
instruments® Brasil
Importação e Exportação LTDA
P: 55 11 6672-3008
F: 55 11 6672-3695
E: brazil@hannainst.com
HANNA
instruments® (India) Pvt. Ltd.
P: 91-22-2756 6435
F: 91-22-2756 6436
E: india@hannainst.com
HANNA
instruments® France
P: (03) 8876.9188
F: (03) 8876.5880
E: france@hannainst.com
HANNA
Indonesia
Germany
Canada
PT. HANNA instruments® Indotama
P: 62 (021) 4525106
F: 62 (021) 458 4294242942
E: indonesia@hannainst.com
HANNA
HANNA
instruments® Canada Inc.
P: (450) 629.1444
F: (450) 629.3335
E: canada@hannainst.com
HANNA
instruments® Deutschland
GmbH
P: (07851) 9129-0
F: (07851) 9129-99
E: germany@hannainst.com
Japan
South Africa
instruments® (Pty) Ltd
P: (011) 615.6076
F: (011) 615.8582
E: southafrica@hannainst.com
HANNA
Chile
instruments® Equipos Ltda.
P: (2) 2361400
F: (2) 2364009
E: chile@hannainst.com
HANNA
instruments® Japan Co. Ltd
P: (03) 5205.3216
F: (03) 5205.3217
E: japan@hannainst.com
HANNA
HANNAService Srl
P: +39 0444 411649
F: +39 0444 611736
E: africa@hannainst.com
Mexico
S.A. de C.V.
P: +52 (55) 5649 1185
F: +52 (55) 5649 1186
E: mexico@hannainst.com
HANNA
Korea
P: 0502-013-2580
F: 0502-013-2581
E: korea@hannainst.com
HANNA
instruments® Portugal
P: (252) 248670
F: (252) 248679
E: portugal@hannainst.com
Romania
instruments® Romania srl
P: 0040 264.599.459
F: 0040 264.598.740
E: romania@hannainst.com
HANNA
Spain
Greece
instruments® S.L.
P: (902) 420.100 / 420.103 (SAT)
F: (902) 420.101
E: spain@hannainst.com
HANNA
instruments® Hellas Ltd.
P: (210) 823.5192
F: (210) 884.0210
E: greece@hannainst.com
HANNA
Korea
African countries not listed
above
instruments® Poland
P: (89) 539.0961
F: (89) 539.0963
E: poland@hannainst.com
United Kingdom
Hungary
instruments® Service
P: (0036) 62.461.514
E: hanna@hih.hu
E: hungary@hannainst.com
HANNA
instruments® Ltd
P: (01525) 850.855
F: (01525) 853.668
E: unitedkingdom@hannainst.com
HANNA
Malaysia
United States
instruments® USA
P: (800) 426-6287
F: (401) 762-5064
E: unitedstates@hannainst.com
HANNA
instruments® (M) Sdn Berhad
P: (603) 5638.9940
F: (603) 5638.9829
E: malaysia@hannainst.com
HANNA
Italy
HANNA Italia Srl
P: 049.9070211
F: 049.9070504
E: italy@hannainst.com
Oceania
Australia
instruments® Pty Ltd
P: (03) 9769.0666
F: (03) 9769.0699
E: australia@hannainst.com
HANNA
Singapore
instruments® (S) Pte. Ltd
P: (65) 6296.7118
F: (65) 6291.6906
E: singapore@hannainst.com
The Netherlands
Taiwan
Sweden/Norway/Finland/Iceland/Denmark
HannaNorden AB
P: +46 300 404018
F: +46 300 141 22
E: info@hannanorden.com
HANNA
Trading Taiwan Pte. Ltd.
P: 886.2.2552.2041
F: 886.2.2552.2046
E: taiwan@hannainst.com
HANNA
Thailand
instruments® BV
P: (31) 30.28.96.842
F: (31) 30.26.71.427
E: netherlands@hannainst.com
HANNA
instruments® (Thailand) Ltd
P: (662) 619.0708.11
F: (662) 619.0061
E: thailand@hannainst.com
HANNA
Vietnam
instruments® Vietnam
P: (84.8) 9105478/ 79/ 80
F: (84.8) 9105477
E: vietnam@hannainst.com