galeo - Door Entry Direct

galeo - Door Entry Direct
FR
EN
GALEO
Clavier codé rétro-éclairé étanche
Illuminated weatherproof keypad with remote electronics
®
®
Range: Digicode / Gamme: Digicode
INSTALLATION MANUAL
MANUEL D’INSTALLATION
Group Products
INSTALLATION MANUEL
GALEO
Illuminated Weatherproof Keypad with remote electronics
Thank you for buying our products and for the confidence you placed
in our company.
1] GENERAL INFORMATION
Audible and visual feedback.
Dimensions (L x W x D):
GALEO = 110 x 75 x 15mm,
Remote Controller = 147 x 124 x 55mm.
Power supplies: 12V to 24V ac and 12V to 48V dc.
Consumption (when 3 relay outputs activated.
and keypad illuminated):
-12V AC: Standby 90mA,
-24V AC: Standby 46mA,
-12V DC: Standby 100mA,
-24V DC: Standby 55mA,
-48V DC: Standby 30mA.
Environmental tests:
vibrations
110
WEEE
Environmental test:
Salt spray
IP64
75
CE certification
15
Polished heavy duty Zamak® cast alloy.
Backlit keys.
2 to 3 relays.
Surface mount.
TANCE
HIGH RESIS
ISM
TO VANDAL
Free voltage.
Mounting with Torx® screws
Keypad sealed with epoxy.
PCB of remote electronics protected
with a varnish coating.
100 user codes customisable
by each user.
Available in Wiegand version (GALEOW).
-25°C to +70°C
REMOTE CONTROLLER
CE certification
IP52
WEEE
-20°C to +70°C
2] NOTES & RECOMMENDATIONS
Cable
The distance between the GALEO and the remote
electronic can not exceed more than 10 meters.
Make sure that the cable is not near by a high voltage cables (ex: 230 V AC).
Mounting recommendations
Mount the keypad on a flat surface to avoid
any vandalism and to insure the best mounting.
Security advice
Recommended cable between
the GALEO and the remote electronic
To expand the supplied 3 meter cable, select a 2
twisted pairs cable (4 wires), SYT1 0.8MM (AWG 20).
Recommended power supplies
suitable for the GALEO
-ARD12 (230V input)
-BS60 (230V input)
For security advice reasons, change
the factory default master code.
When selecting a master code and user code avoid
sequencial codes (example : 3 4 5 6 7).
Back EMF protection
To secure the system from back electromagnetic
fields do not forget to mount the varistor
in parallel on the lock.
* Tension libre.
cdvi.com
cdvigroup.com
13
INSTALLATION MANUEL
GALEO
Illuminated Weatherproof Keypad with remote electronics
3] MOUNTING KIT
Varistor
(M4x10)
®
Torx
screw)
®
T20 Torx
Spanner
Caps
(M4x30)
mounting
screws
Plastic anchors
Wiring
sealed cap
GALEO
1
1
1
2
2
2
-
Remote
Controller
-
-
-
-
2
2
2
Mounting
plate for
remote electronic box
1
4] MOUNTING
1
2
3
GALEO
®
GALEO
Verify the distance between the
GALEO keypad and its remote
electronic (Refer to page 2 «Notes and
Recommendations»). Place the back
plate of the GALEO on the wall and
the bracket of the remote electronic
then mark with a pen the hole location
then drill the 2 mounting holes (drill bit
Ø 5 mm and 35 MM hole depth)
and the hole wiring access.
4
Insert the 2 plastic anchors in the
holes. Place the back plate of the
GALEO and screw on the wall using
the supplied (M4x30) mounting
screws.
5
®
Insert the cable in the hole
area of the back plate. Then
the keypad on the back
placing first the top in the
and then the bottom.
access
mount
plate,
hooks
6
(x2)
Fasten the GALEO keypad to the back
plate by using the supplied (M4x10)
Torx® screw and T20 Trox spanner
hardware. Place the screw cap at the
bottom of the keypad.
14
cdvi.com
cdvigroup.com
Insert the 2 plastic anchors in the holes.
Place the bracket of the electronic
and screw on the wall using the supplied
M4x30 screws. Slide the box from up
to down on the bracket.
Insert the cable in the remote electronic
and wire the cable to the terminals.
Don not forget to install the varistor
on the lock (Refer to page 2 «Notes
and Recommendations»).
INSTALLATION MANUEL
GALEO
Illuminated Weatherproof Keypad with remote electronics
5] WIRING DIAGRAM GALEO 2 RELAY OUTPUTS
D -693 : Remote electronics
P3
P3 jumper allows
to the user to modify
its own Pin code.
To enable this feature put
the jumper on.
(see Programming section
in the instruction manual)
P2
V
R1 C1 T1 R2 C2 T2
P1
M
P2 PX H
H
+
Input voltage
12 to 24VAC
or 12 to 48VDC
P1
P2
H
- E
Green or blue
V
White
P2 jumper resets the
keypad to factory default
values. Remove the power
from the keypad then put
the jumper.
(see Programming section
in the instruction manual)
Relay
2
Brown
Relay
1
V
V
Power supply
According to lock
specifications
Fail safe lock
Outputs
V
V
Description
Fail secure lock
Input voltage 12V to 24VAC or 12V to 48VDC
Input voltage 12V to 24VAC or 12V to 48VDC
R1
N/C contact relay 1
C1
Common relay 1
T1
N/O contact relay 1
R2
N/C contact relay 2
C2
Common relay 2
T2
N/O contact relay 2
P1
Request-to-exit input relay 1
M
Common of inputs
P2
Request-to-exit input relay 2
H
Timer Contact
+
White wire from keypad
-
Brown wire from keypad
E
Green or Blue wire (illumination)
V Varistor
H (Open)
Keypad mode
H (Close)
Request-to-Enter mode
Request-to-Exit inputs
P1 request-to-exit input activates relay 1.
P2 request-to-exit input activates relay 2.
Latch or toggled output.
H input can be used with a timer
to enable free access by pressing
on any digit key on the keypad.
When the contact is open
then the request-to-enter is disabled.
When the contact is closed then press
any key on the keypad to enter.
cdvi.com
cdvigroup.com
15
INSTALLATION MANUEL
GALEO
Illuminated Weatherproof Keypad with remote electronics
5] PROGRAMMATION
6] WIRING DIAGRAM GALEO 3 RELAY OUTPUTS
D -693 : Remote electronics
P3
P3 jumper allows
to the user to modify
its own Pin code.
To enable this feature put
the jumper on.
(see Programming section
in the instruction manual)
P2
V
R1 C1 T1 R2 C2 T2 R3 C3 T3 P1
M
P2 PX H
H
+
Input voltage
12 to 24VAC
or 12 to 48VDC
P1
V
V
Power supply
According to lock
specifications
Outputs
Fail safe lock
Description
Fail secure lock
V
V
V
Varistor
P2
V
H (Open)
Keypad mode
H (Close)
Request-toEnter mode
R1
C1
T1
R2
C2
T2
R3
Request-to-Exit
inputsH input
can be used with a timer to
enable free access by pressing
on any digit key on the keypad.
C3
T3
P1
M
P2
H
+
E
16
cdvi.com
cdvigroup.com
H
- E
Green or blue
V
Relay
3
White
P2 jumper resets the
keypad to factory default
values. Remove the power
from the keypad then put
the jumper.
(see Programming section
in the instruction manual)
Relay
2
Brown
Relay
1
INSTALLATION MANUEL
GALEO
Illuminated Weatherproof Keypad with remote electronics
7] PROGRAMMING
DEFAULT VALUES
-Without codes.
-Illumination time: 10 seconds.
-Relay release time: 1 second.
-Code length: 5-digit.
-Master Code: 1 2 3 4 5.
-Programming security time :
120 secondes.
-Code length for sub master code:
Version 1 relay (Group 1) =
A and B,
Version 2 relays (Group 2) =
1 and 3
Version 3 relays (Group 3) =
4 and 6.
AUDIBLE SIGNAL:
The buzzer indicates different
audible signals. It can be turned
off by cutting the ST1 wire on the
remote controller
1 short beep: Keypad powered
1 long beep: data computing in
programming or access granted
2 short beeps: Enter or Exit from
programming
4 short beeps: data computing
error.
CODE LENGTH
The master code and the User codes
can be of 4 or 5-digit in length.
All the keypad keys can be used to
A. RESET MASTER CODE
AND USER CODES
1. Enter the master code twice
(1 2 3 4 5 default value master code).
2 beeps are emitted to confirm entry
in programming mode.
2. Press A6 to reset the Master Code
and the User codes.
One beep is emitted. Press on A and B to confirm
reset of all memory of the keypad. Wait for two
beeps. The master code is restored to its default
value 1 2 3 4 5 and all the User codes are deleted
from the keypad. Once the reset is completed then
the keypad returns to a stand-by
operating mode.
OR
1. Cut the power. Put the jumper on P2.
2. Put the power back.
Wait approximately 3 seconds.
Two beeps are emitted to confirm reset
of the keypad. Remove P2 jumper. The master
code is restored to its default value 1 2 3 4 5
and all the User codes are deleted from
the keypad.
B. SETTING CODE LENGTH
program a code. The master code and
the Pin code can be of 4 or 5-digit code.
The master code CAN NOT be used as
a PIN code (User Pin code). The master
code CAN NOT be used as a PIN code
(User Pin code). To delete a specific
User pin Code replace it by 0000 if code
length is 4-digit format or replace it by
00000 if the code is in 5-digit format.
P2 JUMPER:
Reset master code
and user codes.
P3 JUMPER:
modification of individual
code by the user.
1. Enter the master code twice.
(1 2 3 4 5 default value master code).
2 beeps are emitted to confirm entry
in programming mode.
2. Press A4 to program the code length.
One beep is emitted. Press 4 or 5 for the digit
code. One beep is emitted to confirm programming
of the code length.
3. Press A5 to modify the master code.
One beep is emitted. Enter the new 4 or 5-digit
master code. One beep is emitted to confirm programming of the new master code.
4. Press B to exit from programming mode.
2 beeps are emitted to confirm that the keypad
is in stand-by operating mode.
4 beeps indicate a data computing error.
C. CHANGING THE MASTER CODE
The master code is used only to enter
in programming mode.
1. Enter the master code twice.
(1 2 3 4 5 default value master code). 2 beeps
are emitted to confirm entry in programming mode.
cdvi.com
cdvigroup.com
17
INSTALLATION MANUEL
GALEO
Illuminated Weatherproof Keypad with remote electronics
2. Press A5 to modify the master code.
One beep is emitted. Enter the new 4 or 5 digit
master code. One beep is emitted to confirm that
the master code is programmed.
3. Press B to exit from the programming mode.
2 beeps are emitted to confirm that the keypad
is in stand-by operating mode.
D. ADDING, CHANGING
OR DELETING A USER CODE
Group 1: From address 00 to address 99,
relay output 1
1. Enter the master code twice
(1 2 3 4 5 default value master code).
2 beeps are emitted to confirm entry
in programming mode.
2. To add a user code, enter the user location
(from 00 to 99).
If the user location is free 1 beep is emitted,
enter the 4 or 5-digit User code.
3. To Change a User code enter the user
location.
4 beeps are emitted to indicate that user location
is already programmed. Enter a new 4 or 5-digit
code. A beep is emitted to confirm the new
user code.
4. To delete a User code enter the user
location.
4 beeps are emitted. Press 0 0 0 0 0 in 5-digit
length code or 0 0 0 0 in 4-digit length code.
A beep is emitted to confirm the new user code.
default value master code). 2 beeps are emitted
to confirm entry in programming mode.
2. Press A0 to program the key-in keypad
time and the keys lit time.
1 beep is emitted. Enter the time in 10th
of second – 10 for 10 seconds up to 99
for 99 seconds the backlighting dims 10 seconds
after the last keypress or switches off after entering a valid code. Press 00 for permanent illumination keys. One beep is emitted to validate the time.
3. Press A1 to program relay 1
output time (door release time).
1 beep is emitted. For a latched output enter the
time in seconds – 01 for 1 second up to 99 for 99
seconds. Press 00 for a toggled output. One beep
is emitted to validate the time.
4. Press B to exit from programming mode.
2 beeps are emitted to confirm that the keypad
is in stand-by operating mode.
4 beeps indicate a data computing error.
F. RESET MASTER CODE
On stand-by operating mode, put a jumper
on P2.
Wait 1 second and then remove the jumper. One
beep is emitted. The master code is restored
to its default value 1 2 3 4 5 in 5-digit
code and 1 2 3 4 in 4-digit code.
G. CHANGING THE CODE BY A USER
NOTE: If the Pin code is already programmed
or is identical to the master code, then 4 beeps
are emitted. Press B to exit from the programming
mode. 2 beeps are emitted to confirm that
the keypad is in stand-by operating mode.
To authorize a user to modify its own
User code put a jumper on P3 (to disable the
feature remove the jumper).
1. Enter the old user code.
The relay is activated and a beep is emitted.
E. TIME OUTPUTS
This section allows to program the illumination time and the Relay activation time.
1. Enter the master code twice (1 2 3 4 5
18
cdvi.com
cdvigroup.com
2. Enter the 2-digit sub master code (default
sub master code A and B).
A beep is emitted to authorise the modification.
3. Enter the new user code.
2 beeps are emitted to confirm the new code.
INSTALLATION MANUEL
GALEO
Illuminated Weatherproof Keypad with remote electronics
4. Check the new user code to be sure
of the modification.
J. OPTIONAL GALEO 2 AND GALEO 3
PROGRAMMING INSTRUCTION
H. SETTING A SUB MASTER CODE
Programming instructions are the same
as for the GALEO keypad with 1 relay output.
GALEO 2: 2 relay outputs N/O and N/C contacts
8A @ 250V~.
Group 1: From user location 00
to user location 59 to activate relay 1.
Group 2: from user location 60
to user location 99 to activate relay 2
The Sub Master code allows the user to change its
own code without entering in programming mode.
For security reasons the code need to be changed
periodically. This feature makes it easier
and faster to change its code.
1. Enter the master code twice
(1 2 3 4 5 default value master code).
2 beeps are emitted to confirm entry
in programming mode.
2. Press A7 to program a sub master
code for the user individual Pin code
modification.
One beep is emitted. Enter the new 2-digit sub
master code. One beep is emitted to confirm
programming of the sub master code.
Release Time of relay2 enter A2, sub master code
enter A8 (default values 1 and 3).
GALEO 3: 3 relay outputs N/O
and N/C contacts 8A @ 250V~.
Group 1: from user location 00
to user location 59 to activate relay 1.
3. Press B to exit from the programming
mode.
2 beeps are emitted to confirm that the keypad
is in stand-by operating mode.
Group 2: from user location 60
to user location 79 to activate relay 2.
I. Audible Feedback
Release time for relay 3 enter A3
sub master code enter A9 (default values 4 and 6).
Group 3: from user location 80
to user location 99 to activate relay 3.
The audible signal is enabled in programming mode
and when the relay is energised after a valid code.
To enable the audible feedback on a key press:
1. Enter the master code twice (1 2 3 4 5
default value master code).
2 beeps are emitted to confirm entry
in programming mode.
2. Press AA.
One beep is emitted. Press 0 to disable the audible
signal during a keypress. Press 1 to enable the audible signal during a keypress. One beep confirms
the new setting.
3. Press B to exit from programming.
2 beeps are emitted to confirm exit
from programming mode.
cdvi.com
cdvigroup.com
19
INSTALLATION MANUEL
GALEO
Illuminated Weatherproof Keypad with remote electronics
To program Pin codes:
User
location
Code
Name
User
location
Code
Name
User
location
00
34
68
01
35
69
02
36
70
03
37
71
04
38
72
05
39
73
06
40
74
07
41
75
08
42
76
09
43
77
10
44
78
11
45
79
12
46
80
13
47
81
14
48
82
15
49
83
16
50
84
17
51
85
18
52
86
19
53
87
20
54
88
21
55
89
22
56
90
23
57
91
24
58
92
25
59
93
26
60
94
27
61
95
28
62
96
29
63
97
30
64
98
31
65
99
32
66
33
67
REMINDER
20
GALEO Relay 1 (1 output)
Relay 1 : From user location
00 to 99.
cdvi.com
cdvigroup.com
GALEO Relays 2 (2 output)
Relay 1 : From 00 to 59,
Relay 2 : From 60 to 99.
Code
Name
GALEO Relays 3 (3 outputs)
Relay 1 : From 00 to 59,
Relay 2 : From 60 to 79,
Relay 3 : From 80 to 99.
INSTALLATION MANUEL
GALEO
Illuminated Weatherproof Keypad with remote electronics
8] NOTES
cdvi.com
cdvigroup.com
21
INSTALLATION MANUEL
GALEO
Illuminated Weatherproof Keypad with remote electronics
14] PROGRAMMING CHART
Enter Master
code twice
2 x beeps
Illumination
duration
Time Relay 1
Time Relay 2
Time Relay 3
Code length
Master code
A0
A1
A2
A3
A4
A5
1 x beep
1 x beep
1 x beep
1 x beep
1 x beep
1 x beep
10-99 sec
00 = permanent
01-99 sec
00 = toggled
01-99 sec
00 = toggled
01-99 sec
00 = toggled
4’ or 5’
digits
Change master
code
10=Default
01=Default
01=Default
01=Default
5= Default
12345=Default
1 x beep = OK
4 beeps = Error
1 x beep = OK
4 beeps = Error
1 x beep = OK
4 beeps = Error
1 x beep = OK
4 beeps = Error
1 x beep = OK
4 beeps = Error
1 x beep = OK
4 beeps = Error
GALEO
GALEO3R
22
cdvi.com
cdvigroup.com
INSTALLATION MANUEL
GALEO
Illuminated Weatherproof Keypad with remote electronics
Reset
Sub master
code 1
Sub master
code 2
Sub master
code 3
Buzzer (Audible
feedback)
A6
A7
A8
A9
AA
1 x beep
1 x beep
1 x beep
1 x beep
1 x beep
2
digits
2
digits
2
digits
0= Buzzer disabled
AB=default
13=default
46=default
1 x beep = OK
4 beeps = Error
1 x beep = OK
4 beeps = Error
1 x beep = OK
4 beeps = Error
User codes
00-99
4’ or 5’ digit code
4 beeps = User
location: “used”
1 = Buzzer
enabled
A
GALEO
GALEO3R
1 x beep = OK
4 beeps = Error
1 x beep = OK
B
2 x beeps
cdvi.com
cdvigroup.com
23
Reference : G0301FR0234V07
All the information contained within this document (photos, drawing, features, specifications and dimensions)
could be perceptibly different and can be changed without prior notice.
*G0301FR0234V07*
CDVI Group
FRANCE (Headquarter/Siège social)
Phone: +33 (0)1 48 91 01 02
Fax: +33 (0)1 48 91 21 21
CDVI
FRANCE + EXPORT
Phone: +33 (0)1 48 91 01 02
Fax: +33 (0)1 48 91 21 21
CDVI
SUISSE
Phone: +41 (0)21 882 18 41
Fax: +41 (0)21 882 18 42
CDVI
ITALIA
Phone: +39 0321 90573
Fax: +39 0321 908018
CDVI UK
CDVI AMERICAS
CDVI
CHINA
Phone: +86 (0)10 62414516
Fax: +86 (0)10 62414519
CDVI
MAROC
Phone: +212 (0)5 22 48 09 40
Fax: +212 (0)5 22 48 34 69
DIGIT
FRANCE
Phone: +33 (0)1 41 71 06 85
Fax: +33 (0)1 41 71 06 86
CDVI BENELUX
CDVI IBÉRICA
[BELGIUM -NETHERLAND -LUXEMBOURG]
[SPAIN -PORTUGAL]
CDVI SWEDEN
Phone: +32 (0) 56 73 93 00
Fax: +32 (0) 56 73 93 05
Phone: +34 (0)935 390 966
Fax: +34 (0)935 390 970
[CANADA -USA]
Phone: +1 (450) 682 7945
Fax: +1 (450) 682 9590
[SWEDEN -DENMARK -NORWAY -FINLAND]
Phone: +46 (0)31 760 19 30
Fax: +46 (0)31 748 09 30
cdvigroup.com
[UNITED KINGDOM -IRELAND]
Phone: +44 (0)1628 531300
Fax: +44 (0)1628 531003
Toutes les informations mentionnées à titre indicatif sur le présent document (photos, dessins, caractéristiques
techniques et dimensions) peuvent varier et sont susceptibles de modifications sans notification préalable.
Extranet : EXE-CDVI_IM GALEO CMYK A5 EN-FR 06
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising