40B 96
FORCE, PRESSURE and DISPLACEMENT TRANSDUCERS INDICATOR with
INPUT for STRAIN-GAUGE or POTENTIOMETER - ALARM UNITS
Main features
• Strain-gauge or potentiometer input configurable by faceplate
• Sensor supply check
• Easy to calibrate with sensitivity
auto-ranging
• Protected by a personal code
• Configurable by serial link
• Internal linearisation for engineering
units
• Labels provided for the more common
physical units
• Sampling time and trip intervention
programmable between 15 and
120msec with resolution between
4000 and 30000 steps
• Retransmission of the measured
variable signal
• 4 trip points, completely configurable
from the faceplate
• 6 wires calibration
• Version for magnetostrictive sensors
Main applications
•
•
•
•
•
•
•
•
•
Extrusion lines
Rubber presses
Test benches
Lapping machines
Food processing equipment
Weighing
Pressure trips
Positioners
Motorised potentiometers
GENERAL
Microprocessor based indicator in both
96x48 (1/8 DIN) formats manufactured
with SMT. The instruments have a lexan
membrane faceplate (guaranteed to IP65)
which has 3 keys, a 5 digit display and 4
indicating LED’s for the output statuses.
The input signal can be selected from a
wide range of sensors:
• Potentiometer (minimum 100Ω)
• Load cell with sensitivity autoranging
between 1,5 and 3,3mV/V.
• Strain-gauge pressure sensor
• Magnetostrictive position sensors
The selection is made using the faceplate
keys.
A digital input (24Vdc/5mA) is available
for resetting, hold, flash, peak handling or
releasing latch.
The instruments have a maximum of 4
outputs that can be mechanical relays or
logic outputs.
One output of 0/4 to 20mA (max. 500Ω) is
available for retransmitting the measured
input signal.
The retransmission output, the digital
input and the third output are options
available contemporaneously.
Finally, a triac can be fitted to drive
resistive loads up to a maximum of 1A at
240V.
The programming of the instrument is
made easy by grouping the parameters in
function blocks (CFG for the alarm
hysteresis, Inp for the inputs, Out for the
outputs...) and by a simplified data entry
menu.
The configuration can be simplified even
further using the PC programming kit
made up of a connection cable and a
menu guide program that runs under
Windows (data sheet cod.WINSTRUM).
A configurable personal software
protection code (password protection)
can be used to restrict the levels of
editing and displaying the configuration
parameters.
TECHNICAL DATA
INPUTS
Accuracy 0,2% f.s. ±1digit.
Sampling time 120msec with sensor
supply check, configurable down to a
minimum of 15msec with reduction of the
resolution to 4000 steps.
Range: -1999...9999 resolution 1 digit,
-19990...99990 resolution 10 digit,
-1999...28000 resolution 1 digit,
Configurable decimal point position, with
over- and under-range indication.
32-segment configurable linearisation can
be used.
Strain-gauge
350Ω, maximum sensitivity 3.3mV/V with
positive or symmetrical polarisation and
calibration that automatically calculates
the sensitivity.
Potentiometer
Supply 1,2V >100Ω
Magnetostrictive position sensors
Supply 24Vdc / 100mA
Digital input
PNP: Ri = 4,7KΩ (24V, 5mA) 1500V
insulation
NPN: free contact from tension.
Function is configurable as alarm or
POWER SUPPLY
memory reset, hold, flash, zero, display of Standard:
the peak value (max., min. or peak to
100...240Vac/dc ± 10% max 18VA
peak).
Optional:
11...27Vac/dc ± 10% max 11VA
OUTPUTS
50/60Hz, protected by an internal fuse
(not replaceable by the operator).
Relay
with NO (NC) contacts rated at
5A/250Vac/30Vdc a cosϕ = 1.
Logic (only for Out2)
24Vdc (10Vmin a 20mA max).
Triac (only for Out1)
24...240Vac ±10%, 1A max
Snubberless, I2t = 128A2sec
A maximum of 4 trip points can be set as
absolute, deviation or symmetrical
deviation alarms. The hysteresis of each
alarm is individually configurable.
Alarm masking with exclusion on power
up, memory and configurable delay and
minimum intervention time.
The trip point may be set at any point on
the scale.
POWER SUPPLY TRANSMITTER
24V ±10% unstabilised, 50mA max
(100mA max for the 0...20/4...20mA
transmitter input model only)
15Vdc max 50mA
for strain-gauge 5Vdc, 10Vdc max 120mA
for potentiometer (>100 Ω) 1,2Vdc
AMBIENT
CONDITIONS
Working temperature range: 0 to 50°C
Storage temperature range: -20 to 70°C
Humidity: 20 to 85%Ur non-condensing
WEIGHT
320g. in the complete version
Analogue retransmission
resolution 12 bit 0/4...20mA
R max = 500Ω,
0...10V Rmin = 50k.
Serial line
Isolated 2/4 wires, RS422/485 interface
(1200, 2400, 4800, 9600, 19200 baud)
Prot.: GEFRAN CENCAL or MODBUS
FACEPLATE DESCRIPTION
A - PV display: indication of process variable, [digits h.14mm,
(5 digit) Red LED display]
B - Label for engineering units
C - “Function” key
D - “Raise” and “Lower” keys
E - Indication of the states of the outputs
D
A
C
B
IP65 faceplate protection
E
DIMENSIONS and CUT-OUT
108
96
115
48
70
44,5
92
105
10
Dimensions: 96x48mm (1/8DIN)
CONNECTION DIAGRAM
OUT2
OUT1
(TRIAC)
OUT1
Rx
SERIAL LINE
2 WIRES
Gnd
B
A
SERIAL LINE
4 WIRES
data+
data-
20mA
20mA - 3 WIRES
TRANSMITTER
(MAGNETOSTRICTIVE)
TX
OUT3
IN
IN
24V
+ IN
+ IN
- IN
- IN
1.2V
STRAIN-GAUGE
INPUT
POTENTIOMETER
INPUT
PWR
SUPPLY
OUT4 / ANALOG
OUTPUT
DIGITAL
INPUT
!
For a correct installation see the warnings in the users’ manual
ORDER CODE
40B
96
5
POWER SUPPLY
NR. DIGITS
5
5
0
11...27Vac/dc
1
100...240Vac/dc
TRANSMITTER
POWER SUPPLY
SERIAL LINE
1,2Vdc potentiometer
01
0
None
5Vdc
05
2
RS 485
10Vdc
10
15Vdc
15
24Vdc *
24
ALL ***
DIGITAL INPUT / RETRANSMISSION OUTPUT
0
99
OUT 1, OUT 2
Relay, Relay
RR
Relay, Logic
RD
Triac, None
TO
None
1
Digital input
2
0/4...20mA (0...10V) retansmision output **
3
Both **
OUT 3, OUT 4
None
00
Relay, None
R0
Relay, Relay **
RR
* Specific model for use with transmitter 20mA (es for position magnetostrittive sensor) excludes Output 3, Output 4 and retransmission
** Out 4 alternative to retransmission output
*** Selectable (standard 24Vdc)
Please, contact GEFRAN sales people for the codes availability.
GEFRAN spa reserves the right to make any modification of the design or function, at any moment without prior notice
Conformity C/UL/US File no. E198546
The instrument conforms to the European Directives 2004/108/CE and 2006/95/CE with reference to the generic standards:
EN 61000-6-2 (immunity in industrial environment) EN 61000-6-3 (emission in residential environment) EN 61010-1 (safety)
GEFRAN spa via Sebina, 74 - 25050 Provaglio d’Iseo (BS)
Tel. 03098881 - fax 0309839063 - Internet: http://www.gefran.com
DTS_40B96_0509_ENG