ASZ16 HigH-EfficiEncy Split SyStEm HEat pumpS up to 16 SEER

ASZ16 HigH-EfficiEncy Split SyStEm HEat pumpS up to 16 SEER
ASZ16
High-Efficiency
Split System Heat Pumps
Up to 16 SEER
S ubmittal D ata Form
Job Name
Location
Purchaser
Order No.
Engineer
Unit No.
Model No.
Unit Designation
Performance Data Certified By:
Standard Features
•
•
•
•
•
•
•
•
•
•
•
•
•
R-410A chlorine-free refrigerant
High-efficiency scroll compressor
High density foam compressor sound blanket
SmartShift™ technology to ensure quiet reliable defrost
Factory-installed bi-flow liquid-line filter drier
Factory-installed suction-line accumulator
Factory-installed compressor crankcase heater
Factory-installed high-capacity muffler
Service valves with sweat connections and easy access to gauge ports
Copper tube / enhanced aluminum fin coil
Contactor with lug connection
Ground lug connection
AHRI Certified; ETL Listed
Cabinet Features
•
•
•
•
•
•
Amana® brand sound control top design
Wire fan discharge grille
Steel louver coil guard
Baked-on powder-paint finish
Top and side maintenance access
Single-panel access to controls with space provided for field-installed accessories
• When properly anchored, meets the
2010 Florida Building Code unit integrity requirements for hurricane-type
winds (Anchor bracket kits available.)
* Complete warranty details available from your local dealer or at www.amana-hac.com. To receive the Lifetime Unit
Replacement Limited Warranty (good for as long as you own your home) and 10-Year Parts Limited Warranty, online
registration must be completed within 60 days of installation. Online registration is not required in California or Québec.
SF-ASZ16
www.amana-hac.com
11/13
Job Name
Location
Performance Data for Split System
Outdoor Unit:
Outdoor Unit:
Cooling Performance
Supply Air Blower Performance
Total Capacity
MBH
Total Supply Air
CFM
Sensible Capacity
MBH
Ext. Static Pressure
IWG
Outdoor Design TMP
ºF DB / WB
Blower Speed
RPM
Power Output Required
BHP
Air Temp entering
Evaporator Coil
ºF
Motor Ratings
HP
Power Input Required
kW
Power Input Required
kW
(less blower motor)
Electrical Data
Heating Performance
Total Heating Capacity
Power Supply
kW
Total Unit Amps
BTU/h
Max Overcurrent Device:
Fuse
Breaker
Amps
Notes
2
www.amana-hac.com
SF-ASZ16
SF-ASZ16
www.amana-hac.com
A
B
C
D
E
6s
= 6SIGMA
8
CC
SPECIAL CHARACTERISTICS:
8
7
= CRITICAL CHARACTERISTIC
35.57
903.4mm
7
SC
6
= SIGNIFICANT CHARACTERISTIC
3
35½
35½
ASZ160601K
4
3
35½
35½
35½
29
D”
38¼
38¼
38¼
38¼
H”
GL
DATE
11-20-08
2
DRAWING TO BE INTERPRETED IN
ACCORDANCE WITH ASME Y14.100
DIMENSIONS ARE IN INCHES
UNLESS OTHERWISE NOTED
TOLERANCES:
DWN BY: GL
ANGLES ± 1.5°
CHK BY: PAMELA
.X : ± .1
.XX : ± .03
.XXX : ± .015
HOLE Ø : ± .005
TUBE CUT LG: ± .063
1
GSZ130
ASZ16
ENG:
CYRILIEN DATE: 11-20-08
ASZ16
GSZ130
A
REV
SHT 1 OF 1
DO NOT SCALE DRAWING
THE GOODMAN MANUFACTURING
COMPANY, L.P.
35½
ASZ160481K
29
W”
-
CHK DR
1
Dimensions
DESCRIPTION
ASZ160361K
CONFIDENTIAL PROPERTY OF THE GOODMAN MANUFACTURING COMPANY, L.P. NOT TO BE DISCLOSED TO OTHERS, COPIED, OR USED FOR ANY PURPOSE
EXCEPT AS AUTHORIZED IN WRITING. MUST BE RETURNED UPON DEMAND, ON COMPLETION OF ORDER, OR OTHER PURPOSE FOR WHICH IT WAS LENT.
5
2
XXXXX INITIAL RELEASE
Model
A
REV ZONE
ASZ160241K
XXXXXXX
ECN
COMPONENTS AND MATERIALS SPECIFIED HEREIN WILL ALSO CONFORM TO THE APPLICABLE SECTION OF GOODMAN MSP 824.01 WORKMANSHIP
STANDARD FOR FIT, FEEL AND FINISH.
Rear View
Side View
Top View
4
26.50
673.1mm
26
661.0mm
5
26.50
673.1mm
26
661.0mm
6
A
B
C
D
E
Job Name
Location
Certified Dimensions
3
Job Name
Location
Accessories List
Model
Description
ASZ16
024
ASZ16
036
ASZ16
048
ASZ16
060
X
ABK-20
Anchor Bracket Kit*
X
X
X
CSR-U-1
Hard-start Kit
X
X
X
CSR-U-3
Hard-start Kit
FSK01A¹
Freeze Protection Kit
X
X
X
X
LAKT01A
Low-Ambient Kit
X
X
X
X
OT18-60A²
Outdoor Thermostat w/ Lockout Stat
X
X
X
X
TX2N4A³
TXV Kit
X
TX3N4³
TXV Kit
TX5N4³
TXV Kit
X
X
*
¹
²
³
√
X
X
Contains 20 brackets; four brackets needed to anchor unit to pad
Installed on indoor coil
Required for heat pump applications where ambient temperatures fall below 0° F with 50% or higher relative humidity.
Condensing units and heat pumps with reciprocating compressors require the use of start-assist components when used in conjunction with an indoor coil using a non-bleed thermal expansion valve refrigerant metering device. The TXV should always be sized based on the tonnage of the outdoor unit.
Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P. All rights reserved. Our continuing
commitment to quality products may mean a change in specifications without notice. © 2013 • Goodman Company, L.P. • Houston, Texas • Printed in the USA.
4
www.amana-hac.com
SF-ASZ16
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement