AUTOMIX 10
TECHNICAL DATA
Type of control
Voltage
Adapter
Power consumption
Torque
Angle of rotation
Heating curve
Parallel displacement
Min. supply water limiter
Max. supply water limiter
Room sensor AM 10 RB
Remote control AM 10 RC
Freeze protection
Manual operation
Protection class
Dimensions
Weight
PI-control with microprocessor
18 VAC 50/60 Hz
230/18 VAC 200 mA with 1.7 m wire
3 VA
5 Nm
90°, electrically limited
1 – 9, stepless
±10°C supply water temperature, stepless
+15°C - +35°C supply water temperature
+40°C - +90°C supply water temperature
+12°C - +27°C room temperature
-9°C - +6°C supply water temperature
+15°C - +35°C supply water temperature
Yes, when necessary
IP 40
80 x 90 x 93 mm
0.6 kg
AUTOMIX 10 is an advanced, compact outdoor reset control for hydronic radiator and radiant floor heating applications.
AUTOMIX 10 works continuously and proportionally. Through impulses from the sensors the control resets the supply water temperature as
the outdoor temperature changes.
AUTOMIX 10 includes a min. and max. limiter for the supply water
temperature and a freeze protection feature. AUTOMIX 10 is delivered factory wired which minimizes installation problems in the field.
The main supply and all sensors have plug-in connections. The quick
and easy do-it-yourself installation saves on labor charges.
AUTOMIX 10 INCLUDES
1. Valve motor AUTOMIX 10 with built-in electronics
2. Mounting kit
3. Adapter 230/18 VAC 200 mA with 1.7 m wire
4. Supply water sensor T1 with 1 m wire
5. Outdoor sensor T2 with 15 m wire
6. Room sensor AUTOMIX 10 RB with 15 m wire (optional)
7. Remote control AUTOMIX 10 RC with 15 m wire (optional)
ORDERING DATA
Order No. Type
1210
AUTOMIX 10 outdoor reset control
AUTOMIX 10 RB room sensor
1211
AUTOMIX 10 RC remote control
1212
LK ACASO AB
Box 634
SE-521 21 Falköping
Tel: +46 515 107 50
Fax: +46 515 590 30
E-mail: info@lkacaso.se
Internet: www.lkacaso.se
AUTOMIX 10
REMOTE CONTROL AUTOMIX 10 RC
RG Reklam AB 05.02
ROOM SENSOR AUTOMIX 10 RB
AUTOMIX 20
TECHNICAL DATA
Type of control
PI-control with microprocessor
Voltage
230/18 VAC 50/60 Hz
Power consumption
3 VA
Torque
5 Nm
Angle of rotation
90°, electrically limited
Min. supply water limiter
+5°C... +30°C, supply water temperature
Max. supply water limiter
+20°C... +80°C, supply water temperature
Room temperature setting
+5°C... +25°C, stepless
Night setback
7 or 9 hours
Temperature set back
1°C, 2°C or 3°C, room temperature
Freeze protection
+5°C... +30°C, supply water temperature
Manual operation
Yes, in case of power failure
Protection class, room thermostatIP 30
Protection class, motor
IP 41
Dimensions of room thermostat 70 x 70 x 30 mm
Weight
0,8 kg
AUTOMIX 20 is an advanced electronic temperature control for radiator
and radiant floor heating applications. AUTOMIX 20 includes an electronic programmer with night and day program, adjustments for minimum
and maximum supply water temperatures and a freeze protection feature.
All essential settings are adjustable. AUTOMIX 20 is ready for mounting
on a mixing valve and can easily be integrated into existing heating systems. AUTOMIX 20 is delivered factory wired which minimizes installation problems in the field. The electrical power supply and all sensors
have plug-in connections. AUTOMIX 20 plug-in compact control unit is
simple to install, program and use. The quick and easy do-it-yourself installation saves on labour charges.
AUTOMIX 20 INCLUDES
1. Room thermostat AM-20 with microprocessor, electronic programmer
with daily program facility, four LEDs far indication
2. Valve motor 24 VAC 50/60 Hz
3. Supply water sensor T1 with 1 m wire
4. Main wire 15 m
5. Power supply plug-in transformer 230/18 VAC 50/60 Hz 190 mA
1,7 m wire
ORDERING DATA
Order No: Type:
1220
AUTOMIX 20 room temperature control
1885
Main wire 23 m
1886
Main wire 40 m
1887
Main wire 60 m
LK ACASO AB
Box 634
SE-521 21 Falköping
Tel: +46 515 107 50
Fax:+46 515 590 30
E-mail: info@lkacaso.se
Internet: www.lkacaso.se
AUTOMIX 20
has an electronic 24 hour
programmer for night
setback
A night setback of 1°C, 2°C or
3°C for 7 or 9 hours is easy to
program. AUTOMIX 20 will repeat
the setting every 24 hours until a
different setback program has
been entered.
needs no outdoor sensor
AUTOMIX 20 responds to all
kinds of temperature changes in
the house caused by e.g. solar
heat through windows, outdoor
winds etc. The microprocessor
compensates for such changes of
temperature which a system with
an outdoor sensor cannot do.
is simple to install and
to operate
AUTOMIX 20 is delivered factory
wired. The main wire, the supply
water sensor and the adapter have
plug-in connections. The room
thermostat and the valve motor are
connected through the main wire.
The supply water sensor and the
adapter are to be plugged into the
valve motor. AUTOMIX 20 can’t
be installed the wrong way.
has no graph to be set
A temperature control with an
outdoor sensor requires a graph
setting. To select the proper graph
in advance is very difficult. It
usually involves a period of trial
and error causing fluctuations in
the indoor temperature.
AUTOMIX 20 needs no graph
selecting. The desired
temperature is to be set at the
room thermostat and that’s it.
has min/max supply water
limiter
AUTOMIX 20 controls both floor
and radiator heating systems.
To set the supply water limiter at
45°C or below makes the
AUTOMIX select a slower program
especially designed to regulate
floor temperatures. Setting the
water limiter above 45°C provides
a control unit ready to regulate
radiator heating systems.
has freeze protection
Freeze protection mode is
obtained by setting the room
temperature to +5°C. The night
setback function does not
operate while AUTOMIX 20 is
in freeze protection mode.
controls both floor heating
systems and radiator
systems
Through well thoughtout
development work AUTOMIX 20
controls both floor heating
systems and radiator systems.
is an advanced electronic
temperature control
All settings are made at the room
thermostat. Through impulses from
the room sensor, changes of room
temperatures are forwarded to a
microprocessor which directs the
motor to keep the plug of the
mixing valve in the position that
corresponds to the heat required
in the house.
altefur 09.02
also responds to the
influence of other heating
factors in the house
AUTOMIX 20 responds to the
temperature changes in the
house caused by solar gain
through the windows, by internal
heat gains or by outside wind
for which outdoor sensor
controls can’t compensate.
AUTOMIX 30
AUTOMIX 30 is an electronic temperature control for hydronic radiator and radiant
TECHNICAL DATA
floor heating applications.
Type of control
PI-control with microprocessor
Voltage
230/18 VAC 50/60 Hz
Power consumption
4 VA
Torque
5 Nm
Angle of rotation
90°
Min. supply water limiter
+5°C - +35°C, supply water temperature
Max. supply water limiter
+20°C - +90°C, supply water temperature
and right turning of valve motor and a freeze protection feature. AUTOMIX 30 has
Freeze protection
+5°C - +35°C, supply water temperature
room sensor, pump control with warm weather shut down and remote control as
Pump control AM 30 PC
+15°C - +25°C, outdoor temperature
options. The main supply and all sensors have plug-in connections which minimizes
Heating curve
1 - 9, stepless
installation problems in the field.
Parallel displacement
±10°C, supply water temperature, stepless
AUTOMIX 30 plug-in compact control unit is simple to install, program and operate.
Remote control AM 30 RC
-9 - +6°C, supply water temperature
The quick and easy do-it-your-self installation saves on labor charges.
Night setback
0ºC - 10°C, supply water temperature
AUTOMIX 30 is available in three designs with options: AUTOMIX 30 E - electronic
programmer with 24 h program facility for night setback. AUTOMIX 30 Q – quartz
programmer with day- and weekly program facility for night setback. AUTOMIX 30 D
digital programmer with day- and weekly program facility for night setback.
AUTOMIX 30 has an automatic booster function after night setback. AUTOMIX 30
includes adjustments for min. and max. supply water temperatures, settings for left-
Room sensor AM 30 RA/RB +12°C - +27°C, room temperature
AUTOMIX 30 INCLUDES
Protection class, controller
IP 40
1. Electronic controller AM 30 E, AM 30 Q or AM 30 D with four LEDs for indication
Manual operation
Yes, when necessary
2. Valve motor 24 VAC 50/60 Hz
Dimensions, controller
75 x 90 x 130 mm
3. Supply water sensor T1 with 3 m wire
Weight
1.2 kg
4. Outdoor sensor T2 with 15 m wire
5. Power supply plug-in transformer 230/18 VAC 50/60 Hz 200 mA 1.7 m wire
ORDERING DATA
Order No. Type
LK ACASO AB
Box 634
SE-521 21 Falköping
Tel: +46 515 107 50
Fax: +46 515 590 30
E-mail: info@lkacaso.se
Internet: www.lkacaso.se
1300
AUTOMIX 30 E – electronic programmer
1301
AUTOMIX 30 Q – quartz programmer
1302
AUTOMIX 30 D – digital programmer
1303
AM 30 RA room sensor with 15 m wire for AUTOMIX 30 E
1304
AM 30 RB room sensor with 15 m wire for AUTOMIX 30 Q and 30 D
1305
AM 30 RC remote control with 15 m wire
1306
AM 30 PC pump control 230 V 2 A with 2 m wire
8802
Sensor lengthening 10 m, 4-pole plug-in connection
AUTOMIX 30 E
Electronic programmer with 24 h program facility for night setback once in a 24 h
period.
AUTOMIX 30 Q
Quartz programmer with day- and weekly program facility for night setback 6 times in a
24 h period. The programmer has 150 h spring reserve.
AUTOMIX 30 D
Digital programmer with day- and weekly program facility for night setback 8 times in a
24 h period. The programmer has 150 h spring reserve.
ROOM SENSOR AM 30 RA
Room sensor designed for AUTOMIX 30 E.
The room sensor has settings for programming night setback and LEDs for indication.
ROOM SENSOR AM 30 RB
Room sensor designed for AUTOMIX 30 Q
and AUTOMIX 30 D. The room sensor has
LEDs for indication.
REMOTE CONTROL AM 30 RC
Remote control for parallel displacement of
heating curve. AM 30 RC is used instead of
a room sensor. With the remote control the
supply water temperature can be lowered
by up to 9°C and risen by 6°C .
PUMP CONTROL AM 30 PC
Pump control for warm weather shut down.
Adjustable from +15ºC to 25ºC outdoor temperature. A LED indicates when the pump is
off. An interval control starts the circulation
pump and the mixing valve for a short time
once every 48 h
MOUNTING OF AUTOMIX 30
AUTOMIX 30 is delivered with a universal
mounting plate for easy wall- or valve
mounting.
MOUNTING OF AUTOMIX 30
AM 30 RA
AUTOMIX
OFF
7
9
R
AM 30 RB
AUTOMIX
30RA
R
21
AUTOMIX
30RB
R
30RC
21
18
1
2
3
AM 30 RC
18
24
15
27
12
24
15
27
12
C
C
T2
AM 30 PC
AUTOMIX 30 PC
PUMP OFF
19 21
23
17
25
15
AUTOMIX 30PC 230V
MADE IN FINLAND IP41
230V
MODEL S30-1
15
25
IN
3
2
1
MODEL S30-1
60
0
35 20
5
5
5
7
9 10
0
+5 1
+10 0
AUTOMIX 30E
25
15
90 L
R
MAX
MOTOR
MIN
IN
3
2
7
ON
10
MADE IN FINLAND I P41
AUTOMIX 30E
2
1
MODEL S30-1
60
0
35 20
5
5
5
7
9 10
0
+5 1
+10 0
AUTOMIX 30Q
25
15
90 L
R
MAX
MOTOR
MIN
IN
3
2
7
10
90 L
R
MOTOR
MAX
0
5
5
7
9 10
2
ON
60
0
35 20
5
1
MADE IN FINLAND I P41
+5 1
AUTOMIX 30D
AUTOMIX 30Q
MIN
2
7
ON
10
+10 0
MADE IN FINLAND I P41
AUTOMIX 30D
88
56
230V
0
10
PUMP
POWER
128
T3
MODEL S30-1
15
25
IN
3
2
1
T1
60
0
35 20
5
5
5
7
9 10
T2
MAX
90 L
R
MOTOR
0
2
+5 1
7
MOTOR
ON
10
+10 0
AUTOMIX 30Q
T1
MIN
MADE IN FINLAND I P41
56
128
AUTOMIX 30 PC
88
PUMP OFF
19 21
23
17
15
25
90.5
MADE IN FINLAND IP41
10
32
71
AUTOMIX
R
30RA
21
71
18
24
15
80
75
27
12
0
7
9
h
1
o
2 C
3
C
RG Reklam AB 05.02
0
93
33
AUTOMIX 30PC 230V
AUTOMIX VALVE MOTOR SERIES 50
TECHNICAL DATA
Power supply
Power consumption
Torque
Angle of rotation
Operation
Maintenance
Manual operation
Protection type
Protection class
Running time
Connection
Position indication
Housing
Optional
Weight
LK ACASO AB
Box 634
SE-521 21 Falköping
Tel: +46 515 107 50
Fax: +46 515 590 30
E-mail: info@lkacaso.se
Internet: www.lkacaso.se
24 VAC or 230 VAC 50/60 Hz
3 VA
5/10 Nm (See table)
90°
3-point
Maintenance free
Disengagement of gears
IP 41
II (without earth wire)
70 sec, 140 sec or 280 sec (See table)
Cable 1,5 m, 3 x 0,5 mm2
Reversible scale
Plastic
Auxiliary switch
0,4 kg
AUTOMIX VALVE MOTOR SERIES 50 is a compact motor designed to
control rotary mixing valves in hydronic heating applications.
AUTOMIX motor is reversible with fixed limit switches for an operating
range of 90°. The motor can be supplied with an additional auxiliary switch.
AUTOMIX motor can be manually operated in case of a power failure. This
is done by turning the handle on the front. The position of the valve is indicated on the reversible scale.
ORDERING DATA
Order No. Type
Power supply
6051
AUTOMIX 51
24 VAC
6052
AUTOMIX 52
24 VAC
6053
AUTOMIX 53
24 VAC
6054
AUTOMIX 54
230 VAC
6055
AUTOMIX 55
230 VAC
6056
AUTOMIX 56
230 VAC
6050
AM50 auxiliary switch
Other designs on request
Running time Torque
70 sec
5 Nm
140 sec
5 Nm
280 sec 10 Nm
70 sec
5 Nm
140 sec
5 Nm
280 sec 10 Nm
altefur 09.02
AUTOMIX VALVE MOTOR SERIES 50
AUTOMIX 100
TECHNICAL DATA
Type of control
Voltage
Power consumption
Torque
Angle of rotation
Min. supply water limiter
Max. supply water limiter
Pump control
Freeze protection
Heating curve
Parallel displacement
Temperature set back
Room temperature setting
Housing
Protection class, controller
Protection class, motor
Manual operation
Dimensions
Weight
LK ACASO AB
Box 634
SE-521 21 Falköping
Tel: +46 515 107 50
Fax: +46 515 590 30
E-mail: info@lkacaso.se
Internet: www.lkacaso.se
PI-control with microprocessor
230 VAC 50/60 Hz
5 VA
5 Nm or 10 Nm
90° or 180°
+15°C… +30°C, adjustable
+20°C… +80°C, adjustable
+15°C… +25°C, outdoor temperature
+5°C, supply water temperature
1 … 9, stepless
+/- 10°C supply water temperature, stepless
0 … 10°C, room temperature, stepless
+12°C … +26°C, stepless
Plastic, colour black
IP 41
IP 41
Yes, in case of power failure
72 x 90 x 144 mm, wall, panel or rail mounting
1,5 kg
AUTOMIX 100 is an electronic temperature control for hydronic radiator
and radiant floor heating applications. AUTOMIX 100 has a quartz or
digital programmer with day- and weekly program facility.
AUTOMIX 100 includes night setback, an automatic pump operation
with freeze protection and warm weather shut down as well as adjustments for maximum and minimum supply water temperatures. All four
limiters are adjustable. AUTOMIX 100 controls the system even when
the heating season is over. An interval control starts the circulation pump
and the mixing valve for a short time once a day. This prevents the
pump and the mixing valve from getting stuck.
AUTOMIX 100 INCLUDES
1. Electronic controller AM-100, quartz or digital programmer with
spring reserve, day- and weekly program facility, LEDs for indication
2. Valve motor 24 VAC 50/60 Hz
3. Supply water sensor T1 with 3 m wire
4. Outdoor sensor T2 with 15 m wire
5. Electronic room sensor T3 with 15 m wire (Optional)
ORDERING DATA
Order No. Type
1228
AUTOMIX 100 with quartz programmer
1229
AUTOMIX 100 with digital programmer
7005
Electronic room sensor T3
AUTOMIX 100 WITH DIGITAL PROGRAMMER
altefur 09.02
ELECTRONIC ROOM SENSOR T3
AUTOMIX CT AND CTR
TECHNICAL DATA
Type of control
Voltage
Adapter
Power consumption
Angle of rotation
Torque
Running time
Temperature range AM CT
Temperature range AM CTR
Ambient temperature
Max. temperature of sensor
Manual operation
Operation signals
Protection type
Dimensions
Weight AM CT
Weight AM CTR
PI-control with microprocessor
230/18 VAC 50/60 Hz
230/18 VAC 200 mA with 1.7 m wire
3 VA
90°, electrically limited
5 Nm
140 sec
0°C - 90°C, stepless
10°C - 80°C, stepless
-10°C - 80°C
Tmax +110°C
Yes, when necessary
Two LEDs for indication
IP 40
80 x 90 x 93 mm
0.6 kg
0.8 kg
AUTOMIX CT and CTR are compact electronic constant temperature
controls designed to operate 3- and 4-way mixing valves in radiant floor
heatings, solid fuel and industrial applications. The supply water
temperature can be selected steplessly from 0°C to 90°C with CT and
from 10ºC to 80ºC with CTR.
AUTOMIX CT and CTR are easy to mount on new as well as existing
valves. The main supply and the sensors have plug-in connections which
minimizes installation problems in the field. The simple and quick
do-it-your-self installation saves on labor charges.
AUTOMIX CT INCLUDES
1. AUTOMIX CT valve motor 24 VAC 50/60 Hz with built-in electronics
2. Mounting kit
3. Supply temperature sensor T1 with 1 m wire
4. Adapter 230/18 VAC 200 mA with 1.7 m wire
AUTOMIX CTR INCLUDES
1. AUTOMIX CT valve motor 24 VAC 50/60 Hz with built-in electronics
2. Remote control with 15 m wire
3. Mounting kit
4. Supply temperature sensor T1 with 1 m wire
5. Adapter 230/18 VAC 200 mA with 1.7 m wire
ORDERING DATA
Order No. Type
1320
AUTOMIX CT constant temperature control
AUTOMIX CTR constant temperature control with
1321
remote control
LK ACASO AB
Box 634
SE-521 21 Falköping
Tel: +46 515 107 50
Fax: +46 515 590 30
E-mail: info@lkacaso.se
Internet: www.lkacaso.se
AUTOMIX CT IN A FLOOR HEATING SYSTEM
RG Reklam AB 05.02
AUTOMIX CT IN A SOLID FUEL SYSTEM
TERMOBAC
TERMOVAR
TERMOBAC
TECHNICAL DATA
Max. operating temperature
Max. operating pressure
Valve body of brass
Valve body of cast iron
Valve plug
LK ACASO AB
Box 634
SE-521 21 Falköping
Tel: +46 515 107 50
Fax: +46 515 590 30
E-mail: info@lkacaso.se
Internet: www.lkacaso.se
120°C
1.0 MPa (10 bar)
TB 15 – TB 40
TB 40 – TB 50
Viton, reinforced
TERMOBAC 3-way backflow preventer has a low opening pressure
and a low pressure drop. The valves are installed horizontally. The
low opening pressure makes TERMOBAC suitable for installations
where self-circulation is obtainable.
TERMOBAC
FUNCTION
• The backflow preventer is kept closed as long as the pump is running.
Capacity diagramm
• When the loading of the storage tank is finished the circulation pump will
shut off. The TERMOBAC will now prevent self-circulation from storage
tank back to boiler.
ORDERING DATA TERMOBAC BRASS VALVES
Order No. Type
Kvs
8315
TERMOBAC 15 Rp ½ "
6
9
8320
TERMOBAC 20 Rp ¾"
8325
TERMOBAC 25 Rp 1"
14
8332
TERMOBAC 32 Rp 1¼"
16
8320A
8325A
8332A
8340A
TERMOBAC
TERMOBAC
TERMOBAC
TERMOBAC
20
25
32
40
G ¾"
G 1"
G 1¼"
G 1½"
8315K
TERMOBAC 15 K 15 mm
8322K
TERMOBAC 22 K 22 mm
8328K
TERMOBAC 28 K 28 mm
Availabe with NPT-threads
A mm
21,3
26,9
33,7
42,4
B mm
80
80
82
84
C mm
21
21
21
25
D mm
31
31
32
32
E mm
65
65
66
67
Weight kg
0,7
0,7
0,8
0,9
6
9
14
16
26,9
33,7
42,4
48,3
80
80
82
84
21
21
21
25
31
31
32
32
65
65
66
67
0,7
0,7
0,8
0,9
6
6
9
15
22
28
114
114
119
21
21
21
31
31
32
81
81
85
0,8
0,8
1,0
A mm
48,3
60,3
B mm
127
135
C mm
40
48
D mm
48
65
E mm
100
105
Weight kg
2,8
4,2
ORDERING DATA TERMOBAC CAST IRON VALVES
Order No. Type
Kvs
29
8340
TERMOBAC 40 Rp 1½"
8350
TERMOBAC 50 Rp 2"
41
RG Reklam AB 05.02
• In case of power or pump failure the TERMOBAC will open automatically
for self-circulation.
TERMOMAT 1
TECHNICAL DATA
Type of control
Voltage
Power consumption
Output relay contact ratings
Temperature range of sensors
Length of sensors
Temperature display
LED-indicators
Protection class
Thermic valve
Dimensions
Weight, electronic control / valve set
On-off, microprocessor
230 VAC 50/60 Hz
5 VA
2 A 250 VAC
Tmax +110°C
On delivery T1 = 3 m, T2 = 5 m
+10°C … +110°C, 13 mm, three digits
Two LED-indicators: Pump P1 and
P2 running
IP 41
Opening temperature 72°C, with
two return flow preventers
Max. operating temperature +110°C
Max. operating pressure 1,0 MPa
(10 bar)
75 x 90 x 130 mm
0,8 / 2,1 kg
TERMOMAT 1 is a differential temperature control and performance monitor for
storage tank applications in which heat is collected from the storage tank to the
heating boiler. TERMOMAT 1 controls the charging pump and the heat collecting pump. It has a digital display for boiler and tank temperatures and two
LEDs for indication. All essential settings are adjustable. TERMOMAT 1 has a relay to automatically operate an additional heat source. TERMOMAT 1 is delivered factory wired which minimizes installation problems in the field. The main
supply and all sensors have plug-in connections. TERMOMAT 1 plug-in control
unit is simple to install, program and operate. The quick and easy installation
saves on labor charges.
TERMOMAT 1 INCLUDES
1.
2.
3.
4.
Electronic control unit TM1 -G1
Two temperature sensors with wires
Two sensor housings 90 mm with 1/2” threads
TERMOMAT 10 valve set with a thermic loading valve 72°C with
double acting function, three union valves (Optional)
5. Two circulation pumps Grundfos UPS 25 x 60 (Optional)
6. TERMOBAC DB 40 double-acting return-flow preventer Rp 11/2”
(Optional)
ORDERING DATA
Order No. Type
8001
TERMOMAT 1
8010
8011
8012
8014
8015
LK ACASO AB
Box 634
SE-521 21 Falköping
Tel: +46 515 107 50
Fax: +46 515 590 30
E-mail: info@lkacaso.se
Internet: www.lkacaso.se
8440
Differential temperature control without valve
set
TERMOMAT 10
Valve set with thermic loading valve 72ºC
and three union valves Rp1”
TERMOMAT 11
Differential temperature control with valve set
TERMOMAT 12
Differential temperature control with valve set
and two circulation pumps
TERMOMAT 14
Differential temperature control with
TERMOBAC DB 40 and two union valves Rp1”
TERMOMAT 15
Differential temperature control with
TERMOBAC DB 40, two union valves and
two circulation pumps
TERMOBAC DB 40 Double-acting return flow preventer Rp 11/2”
FUNCTION WITH TERMOMAT 10 THERMIC LOADING VALVE
FUNCTION WITH TERMOBAC DB 40 RETURN-FLOW PREVENTER
•
The boiler temperature is adjustable 60°C - 80°C. Pump P1 starts
charging from boiler to storage tank when the boiler temperature
Tk has reached the selected temperature and stops when the boiler
temperature Tk is 1°C below this temperature.
•
The boiler temperature is adjustable 60°C - 80°C. Pump P1 starts
charging from boiler to storage tank when the boiler temperature
Tk has reached the selected temperature and stops when the boiler
temperature Tk is 1°C below this temperature.
•
The charging back from storage tank to boiler starts with pump P2
when the boiler temperature Tk is 4°C below storage tank temperature Ta and stops when temperature Tk is 2°C below temperature Ta.
•
The charging back from storage tank to boiler starts with pump P2
when the boiler temperature Tk is 4°C below storage tank temperature Ta and stops when temperature Tk is 2°C below temperature Ta.
•
If the boiler temperature Tk drops below +40ºC, the relay starts the
additional heat source and the pumps stop. If the additional heat
source is not on, the charging from storage tank to boiler continues
to work normally.
•
If the boiler temperature Tk drops below +40ºC, the relay starts the
additional heat source and the pumps stop. If the additional heat
source is not on the charging from storage tank to boiler continues
to work normally.
•
TERMOMAT 10 thermic loading valve has two built in return-flow
preventers. The valve is designed to avoid self-circulation in two
directions and to ensure a minimum working temperature of 72°C
in the heating boiler. This encreases the efficiency, prevents tarring
and considerably prolongs the lifetime of the solid-fuel boiler.
•
TERMOBAC DB 40 double-acting return-flow preventer has a low
opening pressure and a low pressure drop. The valve is designed
to avoid self-circulation in two directions.
altefur 09.02
TERMOMAT 1
TERMOMAT 2 AND 3
TECHNICAL DATA
On-off, microprocessor
230 VAC 50 Hz
3 VA
2 A, 400 VA
T1 = 6 m, T2 = 3 m, T3 = 3 m
Sensors can be lengthened max. 70 m
with 2 x 1.5 mm2 and max. 100 m
with 2 x 2.5 mm2 wires
T1 = 3 m, T2 = 5 m, T3 = 5 m
Sensors, Termomat 3
Sensors can be lengthened 10 m
with Order No. 8802
Temperature range of sensors -30°C - +120°C
Digital display
Range +15°C - +110°C, LED 3-digits
LED indicators
Red LED – pump runs
Blue LED – additional heat/burner on
Protection class
IP 40
Dimensions
75 x 90 x 130 mm
1.1 kg
Weight
Type of control
Voltage
Power consumption
Output relay contact ratings
Sensors, Termomat 2
TERMOMAT 2 is a differential temperature control and perfomance
monitor for storage tank applications with twin storage tanks in
which heat is collected from the primary tank to a secondary tank or
boiler. It controls the charging pump. TERMOMAT 2 has a relay for
automatic operation of an additional heat source.
TERMOMAT 2 INCLUDES
1. Electronic control unit TM2-G1
2. Three temperature sensors with wires
3. Three sensor housings with G ½” threads
4. Mounting plate with screws
TERMOMAT 3 is a differential temperature control and performance
monitor designed to charge a storage tank with a pellets or oil heated
boiler. It controls burner and charging pump. The main supply and all
sensors have plug-in connections which minimizes installation problems and saves on labor charges.
TERMOMAT 3 INCLUDES
1. Electronic control unit TM3-G1
2. Three temperature sensors with wires
3. Three sensor housings with G ½” threads
4. Mounting plate with screws
ORDERING DATA
Order No. Type
8002
TERMOMAT 2 differential temperature control
8003
TERMOMAT 3 differential temperature control
Sensor lengthening 10 m with connecting box
8802
LK ACASO AB
Box 634
SE-521 21 Falköping
Tel: +46 515 107 50
Fax: +46 515 590 30
E-mail: info@lkacaso.se
Internet: www.lkacaso.se
FUNCTION OF TERMOMAT 2
FUNCTION OF TERMOMAT 3
• TERMOMAT 2 measures the temperature difference between a primary and a secondary storage tank. The charging pump is controlled so
that the secondary tank keeps its energy with a maintained layering
for as long as possible. When both tanks are out of energy a relay
automatically starts an optional additional heat source. A digital
display shows the temperatures T1, T2 and T3.
• TERMOMAT 3 measures the temperature difference between a storage
tank and a boiler. It controls the burner and the charging pump. When
the storage tank is out of energy, burner and pump start working. A
digital display shows the temperatures T1, T2 and T3.
• The pump starts charging from the primary to the secondary tank as
soon as temperature T1 is above the selected value or temperature T2
is below the selected value.
• The burner stops when temperature T3 is higher than the selected value.
• The pump stops when temperature T3 has reached the selected value,
temperature T2 is higher than T1 or T1 is below the selected value.
• The relay automatically starts the additional heat source when temperature T1 drops below the selected value or T3 is 3°C below the
selected value. In this case the pump does not run.
• The relay does not work when temperature T2 is higher than the
selected value.
• The burner starts when temperature T2 drops below the selected value.
• The pump starts when temperature T1 is above its selected value and
above temperature T2.
• The pump stops when temperature T3 is higher than the selected value.
The pump continues to run for 3 min before stopping.
• A system with a TERMOVAR loading unit ensures a minimum return
water temperature into the boiler, which eliminates the risk of
destructive thermal shock and prolongs the life-time of the boiler.
See TERMOVAR LOADING UNIT brochure.
• With TERMOVAR thermic valve the temperature of the secondary tank
can be limited to 45°C, 55°C, 61°C, 72°C or 80°C.
altefur 09.02
See TERMOVAR LOADING VALVE brochure.
TERMOMAT 5
TECHNICAL DATA
Type of control
Voltage
Power consumption
Output relay contact ratings
Temperature difference
Temperature range of sensors
Length of sensors
Temperature display
High temperature limiter
Protection class
Dimensions
Weight
On-off, microprocessor
230 VAC 50/60 Hz
5 VA
2 A 250 VAC
T 1 … 6°C, adjustable
T1 -30°C … +110°C
T2 -30°C … +110°C
T3 -40°C … +175°C
On delivery T1, T2 = 3 m, T3= 20 m
-9°C … +140°C, 13 mm, three digits
Tmax +20°C … +100°C, adjustable
IP 41
75 x 90 x 130 mm
0,7 kg
TERMOMAT 5 is a differential temperature control and performance monitor for solar heating systems. TERMOMAT 5 controls the heat collecting pump. It has a digital display for three temperatures and a LED for
function. All essential settings are adjustable. TERMOMAT is ready for
mounting. The main supply and all sensors have plug-in connections.
The control is delivered factory wired which minimizes installation problems in the field. TERMOMAT plug-in control unit is simple to install,
program and operate. The quick and easy installation saves on labor
charges.
TERMOMAT 5 INCLUDES
1. Electronic differential control TM5-G1
2. Three temperature sensors: T1 and T2 with 3 m wire, T3 for collector
with 20 m wire
3. Three sensor housings with 1/2” threads, one 90 mm and two
150 mm
ORDERING DATA
Order No. Type
8005
TERMOMAT 5
Sensor lengthening 10 m
8802
LK ACASO AB
Box 634
SE-521 21 Falköping
Tel: +46 515 107 50
Fax: +46 515 590 30
E-mail: info@lkacaso.se
Internet: www.lkacaso.se
altefur 09.02
TERMOMAT 5
TERMOMAT SOLAR
TECHNICAL DATA
Type of control
Voltage
Power consumption
Output relay contact ratings
Temperature difference
Temperature range of sensors
Length of sensors
Temperature display
High temperature limiter
Protection type
Max. pressure
Connections
Dimensions
Weight
LK ACASO AB
Box 634
SE-521 21 Falköping
Tel: +46 515 107 50
Fax: +46 515 590 30
E-mail: info@lkacaso.se
Internet: www.lkacaso.se
On-off, microprocessor
230 VAC 50/60 Hz
45 – 110 VA
2 A, 400 VA
T 1ºC - 6°C, adjustable
T1 -9°C - +110°C
T2 -9°C - +110°C
T3 -9°C - +199°C
On delivery T1 and T2 = 3 m, T3= 20 m
-9°C - +199°C, 13 mm, three digits
Tmax +20°C - +100°C, adjustable
IP 40
1.0 MPa (10 bar)
15 mm, others on request
165 x 200 x 610 mm
10 kg
TERMOMAT SOLAR is a compact, pre-fabricated control unit to be installed
between collectors and storage tank in solar heating applications.
TERMOMAT SOLAR is delivered factory wired which minimizes installation
problems in the field. TERMOMAT SOLAR unit is simple to install and operate. The quick and easy do-it-yourself installation saves on labor charges.
TERMOMAT SOLAR INCLUDES
– Electronic control unit TM5-G1
– Three temperature sensors with 4-pole plug-in connections
– Three sensor housings with G ½" threads: one 90 mm
and two 150 mm
– Pump Grundfos UPS 25-60
– Two stop valves
– Manometer 1.2 MPa (12 bar)
– Flow control and measuring valve
– Safety valve 0.9 MPa (9 bar), others on request
– Backflow preventer
– Filter
– Expansion tank 2 litres, max.1,0 MPa (10 bar)
– Filling and draining valves
– Filling pump with hoses 2 x 3 m ⅜" (optional)
– Expansion tank 5, 8, 12 or 24 litres, max.1.0 MPa (10 bar) (optional)
– Connection set for 5, 8, 12 or 24 litres expansion tank (optional)
TERMOMAT SOLAR
altefur 09.02
ORDERING DATA
Order No. Type
8006
TERMOMAT SOLAR with 2 litres expansion tank
8006-2
TERMOMAT SOLAR without expansion tank
6550
Expansion tank 2 l, max.1.0 MPa (10 bar)
pre-loading pressure 0.25 MPa (2,5 bar)
6551
Expansion tank 5 l, max.1.0 MPa (10 bar)
pre-loading pressure 0.25 MPa (2.5 bar)
6552
Expansion tank 8 l, max.1.0 MPa (10 bar)
pre-loading pressure 0.25 MPa (2.5 bar)
Expansion tank 12 l, max.1.0 MPa (10 bar)
6553
pre-loading pressure 0.25 MPa (2.5 bar)
6556
Expansion tank 24 l, max.1.0 MPa (10 bar)
pre-loading pressure 0.25 MPa (2.5 bar)
6560
Connection set for 5 l expansion tank
Connection set for 8 and 12 l expansion tank
6561
Connection set for 24 l expansion tank
6562
8007
Filling pump with hoses
8802
Sensor lengthening 10 m, 4-pole plug-in connection
TERMOMIX COMPACT MIXING VALVES AK AND A
TECHNICAL DATA
of brass
of cast iron
Max. operating temperature
110°C
110°C
Max. operating pressure
0,6 MPa (6 bar)
0,6 MPa (6 bar)
90°
Angle of rotation
90°
Torque
0,1 Nm
0,1 Nm
Valve body
Brass
Cast iron
Slide
Brass
Brass
Cover
Brass
Aluminium
Spindle
Brass
Brass
Spindle sealing
Two O-rings, EPDM
Two O-rings, EPDM
Motorizing
Suitable for all valves
Suitable for all valves
motors
motors
TERMOMIX A is a series of compact mixing valves for pre-fabricated
mounting on heating boilers, heat exchangers and air heating/cooling
applications. TERMOMIX A compact mixing valves have female or male
threads or compression fittings. TERMOMIX valves have excellent control
characteristics. They control both supply and return lines. The valves can
be mounted in any position. TERMOMIX valves are very suitable for motorizing because of their low torque. The valves are available for righthand or left-hand mounting.
ORDERING DATA
Order No. Type
2020
TERMOMIX A 20 A G 3/4”
4-way mixing valve of brass
with male threads
2512
TERMOMIX A 12 K 12 mm
2515
TERMOMIX A 15 K 15 mm
4-way mixing valve of brass
with compression fittings
4-way mixing valve of brass
with compression fittings
2518
TERMOMIX A 18 K 18 mm
4-way mixing valve of brass
with compression fittings
2519
TERMOMIX A 19 K 19,1 mm
4-way mixing valve of brass
with compression fittings
2520
TERMOMIX A 20 K 20,5 mm
4-way mixing valve of brass
with compression fittings
2522
TERMOMIX A 22 K 22 mm
4-way mixing valve of brass
with compression fittings
LK ACASO AB
Box 634
SE-521 21 Falköping
Tel: +46 515 107 50
Fax: +46 515 590 30
E-mail: info@lkacaso.se
Internet: www.lkacaso.se
2220
TERMOMIX A 20 S Rp 3/4”
4-way mixing valve of cast iron
2225
TERMOMIX A 25 S Rp 1”
4-way mixing valve of cast iron
2232
TERMOMIX A 32 S Rp 1 1/4” 4-way mixing valve of cast iron
TERMOMIX COMPACT MIXING VALVES AK AND A
TERMOMIX AK 4-WAY MIXING VALVES
Order No. Type
Kvs
A mm
B mm
2020*)
A 20 A
5,5
84
74
A 12 K
5,5
117
74
2512
2515
A 15 K
5,5
117
74
2518
A 18 K
5,5
117
74
2519
A 19 K
5,5
117
74
2520
A 20 K
5,5
117
74
2522
A 22 K
5,5
117
74
*) Outside threads, all others with compression fittings
C mm
20 - G 3/4”
12
15
18
19,1
20,5
22
D mm
30
30
30
30
30
30
30
E mm
25
25
25
25
25
25
25
F mm
67
67
67
67
67
67
67
G mm
62
62
62
62
62
62
62
Weight kg
0,7
0,9
0,9
0,9
0,9
0,9
0,9
G mm
62
62
62
Weight kg
2,3
2,6
3,3
Order No.
2220
2225
2232
Type
A 20 S
A 25 S
A 32 S
Kvs
13
12
24
A mm
84
117
117
B mm
74
74
74
C mm
20 - Rp 3/4”
25 - Rp 1”
32 - Rp 1 1/4”
D mm
30
30
30
E mm
25
25
25
F mm
67
67
67
altefur 09.02
TERMOMIX A 4-WAY MIXING VALVES
TERMOMIX MIXING VALVES D AND C
TECHNICAL DATA
Max. operating temperature
Max. operating pressure
Angle of rotation
Torque
Valve body
Slide
Cover
Spindle
Spindle sealing
Motorizing
110°C
1,0 MPa (10 bar)
90°
0,2 Nm for 3-way valves
0,1 Nm för 4-way valves
Cast iron
Brass
Aluminium
Brass
Two O-rings, EPDM
Suitable for all valve motors
Supply
Diverting
Return
From boiler
Mixing
To boiler
LK ACASO AB
Box 634
SE-521 21 Falköping
Tel: +46 515 107 50
Fax: +46 515 590 30
E-mail: info@lkacaso.se
Internet: www.lkacaso.se
TERMOMIX 3-way and 4-way mixing valves of cast iron have been
developed especially for hydronic heating systems, boilers, heat
exchangers and air heating/cooling applications. TERMOMIX valves
can be used as mixing valves or as diverting valves. There are several
ways of installing. TERMOMIX valves have excellent control
characteristics. They control both supply and return lines. The valves can
be mounted in any position. TERMOMIX valves are very suitable for
motorizing because of their low torque. The valves are available for
right-hand and left-hand mounting.
ORDERING DATA
Order No: Type:
2320
TERMOMIX
2325
TERMOMIX
2332
TERMOMIX
2340
TERMOMIX
2350
TERMOMIX
D
D
D
D
D
20
25
32
40
50
Rp
Rp
Rp
Rp
Rp
3/4”
1”
1 1/4”
1 1/2”
2”
3-way
3-way
3-way
3-way
3-way
mixing
mixing
mixing
mixing
mixing
valve
valve
valve
valve
valve
2420
2425
2432
2440
2450
C
C
C
C
C
20
25
32
40
50
Rp
Rp
Rp
Rp
Rp
3/4”
1”
1 1/4”
1 1/2”
2”
4-way
4-way
4-way
4-way
4-way
mixing
mixing
mixing
mixing
mixing
valve
valve
valve
valve
valve
TERMOMIX
TERMOMIX
TERMOMIX
TERMOMIX
TERMOMIX
TERMOMIX MIXING VALVES D AND C
TERMOMIX D 3-WAY MIXING VALVES
Order No Type
2320
D 20
2325
D 25
2332
D 32
2340
D 40
2350
D 50
Kvs
13
17
24
31
41
20
25
32
40
50
A mm
B mm
- Rp 3/4”
110
- Rp 1”
112
- Rp 1 1/4” 127
- Rp 1 1/2” 127
- Rp 2”
135
C mm
32
32
36
40
48
D mm
67
67
70
73
80
E mm
92
94
100
101
105
Weight kg
1,7
1,8
2,4
2,7
4,1
Mixing
Mixing
Left
Right
Left
Right
Diverting with constant flow in
the boiler loop and adjustable
flow in the secondary loop
Mixing
Right
Left
Right
Left
TERMOMIX C 4-WAY MIXING VALVES
Kvs
13
17
24
31
41
20
25
32
40
50
A mm
B mm
- Rp 3/4”
110
- Rp 1”
112
- Rp 1 1/4” 127
- Rp 1 1/2” 127
- Rp 2”
135
C mm
32
32
36
40
48
D mm
67
67
70
73
80
E mm
110
112
127
127
135
Weight kg
1,8
1,9
2,6
3,1
4,6
altefur 09.02
Order No Type
2420
C 20
2425
C 25
2432
C 32
2440
C 40
2450
C 50
TERMOMIX COMPACT MIXING VALVES DA AND CA
TECHNICAL DATA
Max. operating temperature
Max. operating pressure
Angle of rotation
Torque
Valve body
Slide
Cover
Spindle
Spindle sealing
Motorizing
110°C
0,6 MPa (6 bar)
90°
0,2 Nm for 3-way valves
0,1 Nm for 4-way valves
Brass
Brass
Brass
Brass
Two O-rings, EPDM
Suitable for all valve motors
Supply
Diverting
Return
From boiler
Mixing
To boiler
LK ACASO AB
Box 634
SE-521 21 Falköping
Tel: +46 515 107 50
Fax: +46 515 590 30
E-mail: info@lkacaso.se
Internet: www.lkacaso.se
TERMOMIX 3-way and 4-way compact mixing valves of brass have
been developed especially for small hydronic heating systems, boilers,
heat exchangers and air heating/cooling applications. TERMOMIX
valves can be used as mixing valves or as diverting valves. There are
several ways of installing. TERMOMIX valves have excellent control
characteristics. They control both supply and return lines. The valves
can be mounted in any position. TERMOMIX valves are very suitable
for motorizing because of their low torque. The valves are available
for right-hand and left-hand mounting.
ORDERING DATA
Order No. Type
3520
TERMOMIX
3525-4
TERMOMIX
TERMOMIX
3525-6,3
3532-8
TERMOMIX
3532-12
TERMOMIX
TERMOMIX
3540
D
D
D
D
D
D
20
25
25
32
32
40
A
A
A
A
A
A
G
G
G
G
G
G
3/4”
1”
1”
1 1/4”
1 1/4”
1 1/2”
3-way
3-way
3-way
3-way
3-way
3-way
mixing
mixing
mixing
mixing
mixing
mixing
valve
valve
valve
valve
valve
valve
TERMOMIX
TERMOMIX
TERMOMIX
TERMOMIX
TERMOMIX
TERMOMIX
C
C
C
C
C
C
20
25
25
32
32
40
A
A
A
A
A
A
G
G
G
G
G
G
3/4”
1”
1”
1 1/4”
1 1/4”
1 1/2”
4-way
4-way
4-way
4-way
4-way
4-way
mixing
mixing
mixing
mixing
mixing
mixing
valve
valve
valve
valve
valve
valve
3620
3625-4
3625-6,3
3632-8
3632-12
3640
TERMOMIX COMPACT MIXING VALVES DA AND CA
TERMOMIX DA 3-WAY MIXING VALVES
Order No.
3520
3525-4
3525-6,3
3532-8
3532-12
3540
Type
D 20 A
D 25 A
D 25 A
D 32 A
D 32 A
D 40 A
Kvs
2,5
4
6,3
8
12
15
20
25
25
32
32
40
A mm
- G 3/4”
- G 1”
- G 1”
- G 1 1/4”
- G 1 1/4”
- G 1 1/2”
B mm
80
80
80
82
82
84
C mm
21
21
21
21
21
25
D mm
61
61
61
62
62
65
E mm
74
74
74
75
75
75
Weight kg
0,70
0,70
0,70
0,75
0,75
0,85
Mixing
Mixing
Left
Right
Left
Right
Diverting with constant flow in
the boiler loop and adjustable
flow in the secondary loop.
Mixing
Right
Left
Right
Left
TERMOMIX CA 4-WAY MIXING VALVES
Type
C 20 A
C 25 A
C 25 A
C 32 A
C 32 A
C 40 A
Kvs
2,5
4
6,3
8
12
15
A mm
20 - G 3/4”
25 - G 1”
25 - G 1”
32 - G 1 1/4”
32 - G 1 1/4”
40 - G 1 1/2”
Left
B mm
80
80
80
82
82
84
C mm
21
21
21
21
21
25
D mm
61
61
61
62
62
65
E mm
80
80
80
82
82
84
Weight kg
0,80
0,80
0,80
0,85
0,85
0,90
Right
altefur 09.02
Order No.
3620
3625-4
3625-6,3
3632-8
3632-12
3640
TERMOMIX COMPACT MIXING VALVES DK AND CK
TECHNICAL DATA
Max. operating temperature
Max. operating pressure
Angle of rotation
Torque
Valve body
Slide
Cover
Spindle
Spindle sealing
Motorizing
TERMOMIX 3-way and 4-way compact mixing valves of brass with compression fittings have been developed especially for small hydronic heating systems, boilers, heat exchangers and air heating/cooling applications. TERMOMIX valves can be used as mixing valves or as diverting
valves. There are several ways of installing. TERMOMIX valves have excellent control characteristics. They control both supply and return lines.
The valves can be mounted in any position. TERMOMIX valves are very
suitable for motorizing because of their low torque. The valves are available for right-hand and left-hand mounting.
110°C
0,6 MPa (6 bar)
90°
0,2 Nm for 3-way valves
0,1 Nm for 4-way valves
Brass
Brass
Brass
Brass
Two O-rings, EPDM
Suitable for all valve motors
Supply
Diverting
Return
From boiler
Mixing
To boiler
LK ACASO AB
Box 634
SE-521 21 Falköping
Tel: +46 515 107 50
Fax: +46 515 590 30
E-mail: info@lkacaso.se
Internet: www.lkacaso.se
ORDERING
Order No.
5312
5315
5318
5319
5320
5322
5328-4
5328-6,3
DATA
Type
TERMOMIX
TERMOMIX
TERMOMIX
TERMOMIX
TERMOMIX
TERMOMIX
TERMOMIX
TERMOMIX
D
D
D
D
D
D
D
D
12
15
18
19
20
22
28
28
K
K
K
K
K
K
K
K
12 mm
15 mm
18 mm
19,1 mm
20,5 mm
22 mm
28 mm
28 mm
3-way
3-way
3-way
3-way
3-way
3-way
3-way
3-way
mixing
mixing
mixing
mixing
mixing
mixing
mixing
mixing
valve
valve
valve
valve
valve
valve
valve
valve
5412
5415
5418
5419
5420
5422
5428-4
5428-6,3
TERMOMIX
TERMOMIX
TERMOMIX
TERMOMIX
TERMOMIX
TERMOMIX
TERMOMIX
TERMOMIX
C
C
C
C
C
C
C
C
12
15
18
19
20
22
28
28
K
K
K
K
K
K
K
K
12 mm
15 mm
18 mm
19,1 mm
20,5 mm
22 mm
28 mm
28 mm
4-way
4-way
4-way
4-way
4-way
4-way
4-way
4-way
mixing
mixing
mixing
mixing
mixing
mixing
mixing
mixing
valve
valve
valve
valve
valve
valve
valve
valve
TERMOMIX COMPACT MIXING VALVES DK AND CK
TERMOMIX DK 3-WAY MIXING VALVES
Order No.
5312
5315
5318
5319
5320
5322
5328-4
5328-6,3
Type
D 12 K
D 15 K
D 18 K
D 19 K
D 20 K
D 22 K
D 28 K
D 28 K
Kvs
2,5
2,5
2,5
2,5
2,5
2,5
4
6,3
A mm
12
15
18
19,1
20,5
22
28
28
B mm
114
114
114
114
114
114
120
120
C mm
21
21
21
21
21
21
21
21
D mm
61
61
61
61
61
61
61
61
E mm
93
93
93
93
93
93
93
93
Weight kg
0,8
0,8
0,8
0,8
0,8
0,8
0,8
0,8
Mixing
Mixing
Left
Right
Left
Right
Diverting with constant flow in
the boiler loop and adjustable
flow in the secondary loop
Mixing
Right
Left
Right
Left
TERMOMIX CK 4-WAY MIXING VALVES
Type
C 12 K
C 15 K
C 18 K
C 19 K
C 20 K
C 22 K
C 28 K
C 28 K
Kvs
2,5
2,5
2,5
2,5
2,5
2,5
4
6,3
A mm
12
15
18
19,1
20,5
22
28
28
Left
B mm
114
114
114
114
114
114
120
120
C mm
21
21
21
21
21
21
21
21
D mm
61
61
61
61
61
61
61
61
E mm
114
114
114
114
114
114
120
120
Weight kg
0,9
0,9
0,9
0,9
0,9
0,9
0,9
0,9
Right
altefur 09.02
Order No.
5412
5415
5418
5419
5420
5422
5428-4
5428-6,3
TERMOMIX COMPACT MIXING VALVE DS AND CS
TECHNICAL DATA
Max. operating temperature
Max. operating pressure
Angle of rotation
Torque
Valve body
Slide
Cover
Spindle
Spindle sealing
Motorizing
110°C
1,0 MPa (10 bar)
90°
0,2 Nm for 3-way valves
0,1 Nm for 4-way valves
Brass
Brass
Brass
Brass
Two O-rings, EPDM
Suitable for all valve motors
Return
To boiler
LK ACASO AB
Box 634
SE-521 21 Falköping
Tel: +46 515 107 50
Fax: +46 515 590 30
E-mail: info@lkacaso.se
Internet: www.lkacaso.se
ORDERING DATA
Supply
Diverting
From boiler
Mixing
TERMOMIX 3-way and 4-way compact mixing valves of brass have
been developed especially for small hydronic heating systems,
boilers, heat exchangers and air heating/cooling applications.
TERMOMIX valves can be used as mixing valves or as diverting
valves. There are several ways of installing. TERMOMIX valves
have excellent control characteristics. They control both supply and
return lines. The valves can be mounted in any position. TERMOMIX
valves are very suitable for motorizing because of their low torque.
The valves are available for right-hand and left-hand mounting.
Order No:
3315
3320-4
3320-6,3
3325-8
3325-12
3332
Type:
TERMOMIX
TERMOMIX
TERMOMIX
TERMOMIX
TERMOMIX
TERMOMIX
D
D
D
D
D
D
15
20
20
25
25
32
S
S
S
S
S
S
Rp
Rp
Rp
Rp
Rp
Rp
1/2”
3/4”
3/4”
1”
1”
1 1/4”
3-way
3-way
3-way
3-way
3-way
3-way
mixing
mixing
mixing
mixing
mixing
mixing
valve
valve
valve
valve
valve
valve
3415
3420-4
3420-6,3
3425-8
3425-12
3432
TERMOMIX
TERMOMIX
TERMOMIX
TERMOMIX
TERMOMIX
TERMOMIX
C
C
C
C
C
C
15
20
20
25
25
32
S
S
S
S
S
S
Rp
Rp
Rp
Rp
Rp
Rp
1/2”
3/4”
3/4”
1”
1”
1 1/4”
4-way
4-way
4-way
4-way
4-way
4-way
mixing
mixing
mixing
mixing
mixing
mixing
valve
valve
valve
valve
valve
valve
TERMOMIX COMPACT MIXING VALVES DS AND CS
TERMOMIX DS 3-WAY MIXING VALVE
Order No
3315
3320-4
3320-6,3
3325-8
3325-12
3332
Type
D 15 S
D 20 S
D 20 S
D 25 S
D 25 S
D 32 S
Kvs
2,5
4
6,3
8
12
15
15
20
20
25
25
32
A mm
- Rp 1/2”
- Rp 3/4”
- Rp 3/4”
- Rp 1”
- Rp 1”
- Rp 1 1/4”
B mm
80
80
80
82
82
84
C mm
21
21
21
21
21
25
D mm
61
61
61
62
62
65
E mm
74
74
74
75
75
75
Weight kg
0,70
0,70
0,70
0,75
0,75
0,85
Mixing
Mixing
Diverting with constant flow in
the boiler loop and adjustable
flow in the secondary loop
Mixing
Right
Left
Right
Left
Left
Right
Left
Right
TERMOMIX CS 4-WAY MIXING VALVE
Type
C 15 S
C 20 S
C 20 S
C 25 S
C 25 S
C 32 S
Kvs
2,5
4
6,3
8
12
15
15
20
20
25
25
32
A mm
B mm
- Rp 1/2” 80
- Rp 3/4” 80
- Rp 3/4” 80
- Rp 1”
82
- Rp 1”
82
- Rp 1 1/4” 84
C mm
21
21
21
21
21
25
D mm
61
61
61
62
62
65
E mm
80
80
80
82
82
84
Weight kg
0,80
0,80
0,80
0,85
0,85
0,90
altefur 09.02
Order No
3415
3420-4
3420-6,3
3425-8
3425-12
3432
TERMOMIX MIXING VALVES H
TECHNICAL DATA
Max. operating temperature
Max. operating pressure
Angle of rotation
Torque
Valve body
Slide
Cover
Spindle
Spindle sealing
Motorizing
Optional features
LK ACASO AB
Box 634
SE-521 21 Falköping
Tel: +46 515 107 50
Fax: +46 515 590 30
E-mail: info@lkacaso.se
Internet: www.lkacaso.se
110°C
0,6 MPa (6 bar)
90°
0,1 Nm
Cast iron
Brass
Brass
Brass
Two O-rings, EPDM
Suitable for all valve motors
Fittings
TERMOMIX H is a series of 3-way and 4-way mixing valves of cast iron
for boiler valve units. The valves are available for right-hand and lefthand mounting. The supply and return connections are reversible. On
standard delivery the supply is on the left side. The scale is graduated
on both sides and can be reversed if the valve flow direction is
changed. TERMOMIX H-valves have excellent control characteristics.
They control both supply and return lines. The valves can be mounted in
any position. TERMOMIX H-valves are very suitable for motorizing
because of their low torque.
ORDERING DATA
Order No.
Type
2501
TERMOMIX H4-90 4-way mixing valve
with four male threads G 1”
TERMOMIX H4-90 4-way mixing valve
2502
with two male threads G 1 1/2”
2503
TERMOMIX H4-125 4-way mixing valve
with four male threads G 1”
2504
TERMOMIX H4-125 4-way mixing valve
with two male threads G 1 1/2”
2505
TERMOMIX H3-125 3-way mixing valve
with two male threads G 1 1/2” and by-pass
2506
TERMOMIX H4-125 4-way mixing valve
with two male threads G 1 1/2” and by-pass
TERMOMIX H 3-WAY AND 4-WAY MIXING VALVES
Type
H4-90
H4-90
H4-125
H4-125
H3-125
H4-125
Size
25 - G
25 - G
25 - G
25 - G
25 - G
25 - G
1”
1 1/2”
1”
1 1/2”
1 1/2”
1 1/2”
By-Pass
No
No
No
No
Yes
Yes
Kvs
10
10
10
10
10
10
A mm
90
90
125
125
125
125
H mm
110
110
110
110
110
110
Weight kg
1,3
1,3
1,5
1,5
1,5
1,5
altefur 09.02
Order No.
2501
2502
2503
2504
2505
2506
TERMOMIX THERMOSTATIC MIXING VALVE
TECHNICAL DATA
Max. operating pressure
1,0 Mpa (10 bar)
Max. operating temperature
90°C (194°F)
Adjustable temperature range
38 – 65°C (100 – 149°F)
Pressure drop
See diagram
Valve body
corrosion-resistant DZR-brass
Type approval
SITAC 3402/83
TERMOMIX is an automatic thermostatic 3-way mixing valve designed to
control domestic hot water temperature. The desired water temperature
within the range 38 – 65°C is selected with the knob.
TERMOMIX thermostatic mixing valves are delivered with compression
fittings. When mounted against external threads an adapter is to be used.
TERMOMIX thermostatic mixing valves are delivered with a return-flow
preventer to avoid self-circulation. The valves can be mounted in any
position.
ORDERING DATA
Order No. Type
Size
TERMOMIX 15 mixing valve 15 mm compression fittings
0,33 kg
5522
TERMOMIX 22 mixing valve 22 mm compression fittings
0,40 kg
5515A
Adapter 15
15 mm x Rp 3/4”
female threads
5522A
Adapter 22
E-mail: info@lkacaso.se
Internet: www.lkacaso.se
0,10 kg
22 mm x Rp 3/4”
female threads
LK ACASO AB
Box 634
SE-521 21 Falköping
Tel: +46 515 107 50
Fax: +46 515 590 30
Weight
5515
0,10 kg
TERMOMIX THERMOSTATIC MIXING VALVE
altefur 09.02
FLOW l/s
TERMOVAR AF THERMIC BYPASS VALVE
TERMOVAR AF thermic 3-way bypass valves are designed to change the
direction of flow in hydronic heating applications.
TERMOVAR AF is an automatic valve operated by a self-contained thermostatic element. TERMOVAR AF works without additional energy.
TERMOVAR AF bypass valves have a great range of application. In a
solarsystem TERMOVAR AF ensures an optimum layering of temperature
in the storage tank.
TERMOVAR AF bypass valves are available for right-hand and left-hand
mountings. They can be mounted in any position.
TECHNICAL DATA
Opening temperature
Max. operating temperature
Max. operating pressure
Valve body
LK ACASO AB
Box 634
SE-521 21 Falköping
Tel: +46 515 107 50
Fax: +46 515 590 30
E-mail: info@lkacaso.se
Internet: www.lkacaso.se
45°C, 55°C, 61°C, 72°C or 80°C
110°C
1,0 Mpa (10 bar)
Brass
TERMOVAR AF THERMIC BYPASS VALVE
Order No.
6112
6115
6118
6122
6128
6120
6125
6132
6125A
6132A
6140A
Type
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
AF
AF
AF
AF
AF
AF
AF
AF
AF
AF
AF
12
15
18
22
28
20
25
32
25
32
40
K 45°C
K 45°C
K 45°C
K 45°C
K 45°C
Rp 3/4” 45°C
Rp 1” 45°C
Rp 11/4” 45°C
G 1” 45°C
G 11/4” 45°C
G 11/2” 45°C
Kvs
4
4
6
6
9
6
9
12
6
9
12
A mm
12
15
18
22
28
26,9
33,7
42,4
33,7
42,4
48,3
B mm
119
119
119
119
119
80
82
84
82
84
84
C mm
21
21
21
21
21
21
21
25
21
25
25
D mm
31
31
31
31
31
31
32
32
32
32
32
E mm
85
85
85
85
85
65
66
67
66
66
66
Weight kg
0,8
0,8
0,8
0,8
0,8
0,7
0,8
0,9
0,8
0,9
1,0
6212
6215
6218
6222
6228
6220
6225
6232
6225A
6232A
6240A
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
AF
AF
AF
AF
AF
AF
AF
AF
AF
AF
AF
12
15
18
22
28
20
25
32
25
32
40
K 55°C
K 55°C
K 55°C
K 55°C
K 55°C
Rp 3/4” 55°C
Rp 1” 55°C
Rp 11/4” 55°C
G 1” 55°C
G 11/4” 55°C
G 11/2” 55°C
4
4
6
6
9
6
9
12
6
9
12
12
15
18
22
28
26,9
33,7
42,4
33,7
42,4
48,3
119
119
119
119
119
80
82
84
82
84
84
21
21
21
21
21
21
21
25
21
25
25
31
31
31
31
31
31
32
32
32
32
32
85
85
85
85
85
65
66
67
66
66
66
0,8
0,8
0,8
0,8
0,8
0,7
0,8
0,9
0,8
0,9
1,0
6312
6315
6318
6322
6328
6320
6325
6332
6325A
6332A
6340A
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
AF
AF
AF
AF
AF
AF
AF
AF
AF
AF
AF
12
15
18
22
28
20
25
32
25
32
40
K 61°C
K 61°C
K 61°C
K 61°C
K 61°C
Rp 3/4” 61°C
Rp 1” 61°C
Rp 11/4” 61°C
G 1” 61°C
G 11/4” 61°C
G 11/2” 61°C
4
4
6
6
9
6
9
12
6
9
12
12
15
18
22
28
26,9
33,7
42,4
33,7
42,4
48,3
119
119
119
119
119
80
82
84
82
84
84
21
21
21
21
21
21
21
25
21
25
25
31
31
31
31
31
31
32
32
32
32
32
85
85
85
85
85
65
66
67
66
66
66
0,8
0,8
0,8
0,8
0,8
0,7
0,8
0,9
0,8
0,9
1,0
6412
6415
6418
6422
6428
6420
6425
6432
6425A
6432A
6440A
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
AF
AF
AF
AF
AF
AF
AF
AF
AF
AF
AF
12
15
18
22
28
20
25
32
25
32
40
K 72°C
K 72°C
K 72°C
K 72°C
K 72°C
Rp 3/4” 72°C
Rp 1” 72°C
Rp 11/4” 72°C
G 1” 72°C
G 11/4” 72°C
G 11/2” 72°C
4
4
6
6
9
6
9
12
6
9
12
12
15
18
22
28
26,9
33,7
42,4
33,7
42,4
48,3
119
119
119
119
119
80
82
84
82
84
84
21
21
21
21
21
21
21
25
21
25
25
31
31
31
31
31
31
32
32
32
32
32
85
85
85
85
85
65
66
67
66
66
66
0,8
0,8
0,8
0,8
0,8
0,7
0,8
0,9
0,8
0,9
1,0
6512
6515
6518
6522
6528
6520
6525
6532
6525A
6532A
6540A
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
AF
AF
AF
AF
AF
AF
AF
AF
AF
AF
AF
12
15
18
22
28
20
25
32
25
32
40
K 80°C
K 80°C
K 80°C
K 80°C
K 80°C
Rp 3/4” 80°C
Rp 1” 80°C
Rp 11/4” 80°C
G 1” 80°C
G 11/4” 80°C
G 11/2” 80°C
4
4
6
6
9
6
9
12
6
9
12
12
15
18
22
28
26,9
33,7
42,4
33,7
42,4
48,3
119
119
119
119
119
80
82
84
82
84
84
21
21
21
21
21
21
21
25
21
25
25
31
31
31
31
31
31
32
32
32
32
32
85
85
85
85
85
65
66
67
66
66
66
0,8
0,8
0,8
0,8
0,8
0,7
0,8
0,9
0,8
0,9
1,0
K = compression fittings
Rp = Female threads
G = Male threads
Available with NPT threads
Other temperatures on request
Altefur 09.02
ORDERING DATA
TERMOVAR LOADING UNIT
TECHNICAL DATA
Voltage
Power consumption
Max. boiler capacity
Max. operating temperature
Max. operating pressure
Opening temperature
Loading pump
Sizes
Body
Dimensions
Weight
230 VAC 50/60 Hz
45-110 VA
80 kW
110°C
1.0 MPa (10 bar)
45°C, 55°C, 61°C, 72°C or 80°C, fixed
Grundfos UPS 25-60
Rp 1”, Rp 1¼” and 28 mm
Cast iron
210 x 210 x 110 mm
5.0 kg
TERMOVAR LOADING UNIT has several advantages:
• The pre-fabricated unit saves time and provides a quick and trouble-free installation
• The unit provides a constant loading temperature to the storage tank
• Can be installed on the right-hand or left-hand side of the boiler
• Automatic self-circulation in case of power failure or pump break-down
• The unit is mounted in the return pipe which means that the supply pipe is free for
expansion and the unit is never affected by steam in case of an overheated boiler
• Service friendly. All parts can be changed without draining the system
LK ACASO AB
Box 634
SE-521 21 Falköping
Tel: +46 515 107 50
Fax: +46 515 590 30
E-mail: info@lkacaso.se
Internet: www.lkacaso.se
TERMOVAR LOADING UNIT is a pre-fabricated, automatic, thermally
operated valve unit for solid-fuel boiler/storage tank installations, where
heating and domestic hot water are taken from the storage tank.
TERMOVAR LOADING UNIT ensures a minimum return-water temperature
into the solid-fuel boiler, which increases the boiler efficiency, prevents
tarring and considerably prolongs the lifetime of the solid-fuel boiler.
TERMOVAR eliminates the risk of destructive thermal shock caused by surges of cold return water. TERMOVAR renders a more effective burning and
is therefore a necessary part of a solid fuel installation with a storage tank.
TERMOVAR INCLUDES
1.
2.
3.
4.
5.
6.
Thermally operated loading valve
Backflow preventer
Circulation pump
Three thermometers
Three ball valves
Insulation EPP (optional)
ORDERING DATA
Order No.
Type
4725
TERMOVAR LOADING UNIT 25
Rp 1"
4825
TERMOVAR LOADING UNIT 25
Rp 1"
4925
TERMOVAR LOADING UNIT 25
Rp 1"
Rp 1¼"
TERMOVAR LOADING UNIT 32
4732
4832
TERMOVAR LOADING UNIT 32
Rp 1¼"
4932
TERMOVAR LOADING UNIT 32
Rp 1¼"
28 mm
TERMOVAR LOADING UNIT 28
4728
4828
TERMOVAR LOADING UNIT 28
28 mm
4928
TERMOVAR LOADING UNIT 28
28 mm
4725S
TERMOVAR LOADING UNIT 25
Rp 1"
4825S
TERMOVAR LOADING UNIT 25
Rp 1"
4925S
TERMOVAR LOADING UNIT 25
Rp 1"
Rp 1¼"
TERMOVAR LOADING UNIT 32
4732S
4832S
TERMOVAR LOADING UNIT 32
Rp 1¼"
TERMOVAR LOADING UNIT 32
Rp 1¼"
4932S
4728S
TERMOVAR LOADING UNIT 28
28 mm
4828S
TERMOVAR LOADING UNIT 28
28 mm
4928S
TERMOVAR LOADING UNIT 28
28 mm
S = without backflow preventer, I = with insulation (e.g. 4832SI)
Other temperatures on request.
61ºC
72ºC
80ºC
61ºC
72ºC
80ºC
61ºC
72ºC
80ºC
61ºC
72ºC
80ºC
61ºC
72ºC
80ºC
61ºC
72ºC
80ºC
TERMOVAR LOADING UNIT
1. The heat up phase
The loading pump should be controlled by a thermostat that
measures flue-gas temperature. The pump will start when
the boiler is fired up and stop when it has ceased to fire.
The boiler water is circulating to the loading unit and back
while the temperature of the boiler is rising.
2. The loading phase
The thermostat element in the loading unit is affected by the temperature of the water circulating from the boiler to the loading unit. (See table below.) The thermostat element starts opening at 61/72/80°C * and is fully open at 73/84/92°C *. When the temperature in the boiler reaches
61/72/80°C * the thermostat element opens and allows return water from the storage tank to be mixed with supply water before it returns back to
the boiler. The temperature of the supply water determines the working position of the thermostat element.
A balancing valve in the loading unit regulates the internal flow of the supply water. The working position of the thermostat element determines the
closing position of the balancing valve. (See table below.) When the temperature is 67/78/86°C * the thermostat element starts to close the balancing valve. This causes a higher flow of return water into the boiler. When the temperature reaches 73/84/92°C * the thermostat
element is 100 % open and the balancing valve is 100 % closed.
* depending on selected opening temperature
Thermostat
Temp. °C
Thermostat
Opening position %
61/72/80
63/74/82
65/76/84
67/78/86
69/80/88
71/82/90
73/84/92
0
16
33
50
67
83
100
Balancing valve
Closing position %
0
0
0
0
35
70
100
3. The end phase
The thermostat element is fully open. The balancing valve is
closed. This results a maximum cooling of the boiler and the
storage tank is filled with supply water.
4. Self-circulation
Model S is delivered without
backflow preventer.
Model S
altefur 09.02
In case of power or pump
failure the backflow preventer
will open automatically for
self-circulation.
TERMOVAR LOADING VALVE
TECHNICAL DATA
Opening temperature
Max. operating temperature
Max. operating pressure
Valve body of brass
Valve body of cast iron
45°C, 55°C, 61°C, 72°C
or 80°C fixed temperature
110°C
1.0 MPa (10 bar)
TV 15 – TV 40
TV 40 – TV 50
TERMOVAR LOADING VALVE is an automatic thermally operated
loading valve for solid-fuel boiler/storage tank installations, where
heating and domestic hot water are taken from the tank.
TERMOVAR ensures a minimum return-water temperature in the
heating boiler, which increases the efficiency, prevents tarring and
considerably prolongs the lifetime of the solid-fuel boiler.
TERMOVAR eliminates the risk of destructive thermal shock to both
steel and cast iron boilers. TERMOVAR thermally operated loading
valve renders a more effective burning and is therefore a necessary
part of a solid fuel installation with a storage tank.
TERMOVAR LOADING VALVES may be selected with 45°C, 55°C,
61°C, 72°C or 80°C fixed opening temperatures.
The valves can be delivered factory mounted in any position and
with other temperatures on request.
LK ACASO AB
Box 634
SE-521 21 Falköping
Tel: +46 515 107 50
Fax: +46 515 590 30
E-mail: info@lkacaso.se
Internet: www.lkacaso.se
TERMOVAR LOADING VALVE
ORDERING DATA FOR TERMOVAR BRASS VALVES
Order No. Type
Kvs
A mm
4115
TERMOVAR 15 45°C Rp ½"
4
21,3
4120
TERMOVAR 20 45°C Rp ¾"
6
26,9
4125
TERMOVAR 25 45°C Rp 1"
9
33,7
4132
TERMOVAR 32 45°C Rp 1¼"
12
42,4
20A
25A
32A
40A
45°C
45°C
45°C
45°C
G ½"
G ¾"
G 1"
G 1¼"
4120A
4125A
4132A
4140A
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
4115K
4122K
4128K
TERMOVAR 15K 45°C 15 mm
TERMOVAR 22K 45°C 22 mm
TERMOVAR 28K 45°C 28 mm
4215
4220
4225
4232
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
15
20
25
32
4220A
4225A
4232A
4240A
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
20A
25A
32A
40A
4215K
4222K
4228K
TERMOVAR 15K 55°C 15 mm
TERMOVAR 22K 55°C 22 mm
TERMOVAR 28K 55°C 28 mm
4315
4320
4325
4332
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
15
20
25
32
4320A
4325A
4332A
4340A
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
20A
25A
32A
40A
4315K
4322K
4328K
TERMOVAR 15K 61°C 15 mm
TERMOVAR 22K 61°C 22 mm
TERMOVAR 28K 61°C 28 mm
4415
4420
4425
4432
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
15
20
25
32
4420A
4425A
4432A
4440A
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
20A
25A
32A
40A
4415K
4422K
4428K
TERMOVAR 15K 72°C 15 mm
TERMOVAR 22K 72°C 22 mm
TERMOVAR 28K 72°C 28 mm
4515
4520
4525
4532
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
15
20
25
32
4520A
4525A
4532A
4540A
TERMOVAR
TERMOVAR
TERMOVAR
TERMOVAR
20A
25A
32A
40A
4515K
4522K
4528K
TERMOVAR 15K 80°C 15 mm
TERMOVAR 22K 80°C 22 mm
TERMOVAR 28K 80°C 28 mm
55°C
55°C
55°C
55°C
Rp ½"
Rp ¾"
Rp 1"
Rp 1¼"
55°C
55°C
55°C
55°C
61°C
61°C
61°C
61°C
Rp ½"
Rp ¾"
Rp 1"
Rp 1¼"
61°C
61°C
61°C
61°C
72°C
72°C
72°C
72°C
G ½"
G ¾"
G 1"
G 1¼"
Rp ½"
Rp ¾"
Rp 1"
Rp 1¼"
72°C
72°C
72°C
72°C
80°C
80°C
80°C
80°C
G ½"
G ¾"
G 1"
G 1¼"
G ½"
G ¾"
G 1"
G 1¼"
Rp ½"
Rp ¾"
Rp 1"
Rp 1¼"
80°C
80°C
80°C
80°C
G ½"
G ¾"
G 1"
G 1¼"
POSITION 1
B mm
80
80
82
84
C mm
21
21
21
25
D mm
31
31
32
32
E mm
65
65
66
67
Weight kg
0,7
0,7
0,7
0,8
4
6
9
12
21,3
26,9
33,7
42,4
80
80
82
84
21
21
21
25
31
31
32
32
65
65
66
67
0,7
0,7
0,7
0,8
4
6
9
15,0
22,0
28,0
114
114
119
21
21
21
31
31
32
81
81
85
0,8
0,8
1,0
4
6
9
12
21,3
26,9
33,7
42,4
80
80
82
84
21
21
21
25
31
31
32
32
65
65
66
67
0,7
0,7
0,7
0,8
4
6
9
12
21,3
26,9
33,7
42,4
80
80
82
84
21
21
21
25
31
31
32
32
65
65
66
67
0,7
0,7
0,7
0,8
4
6
9
15,0
22,0
28,0
114
114
119
21
21
21
31
31
32
81
81
85
0,8
0,8
1,0
4
6
9
12
21,3
26,9
33,7
42,4
80
80
82
84
21
21
21
25
31
31
32
32
65
65
66
67
0,7
0,7
0,7
0,8
4
6
9
12
21,3
26,9
33,7
42,4
80
80
82
84
21
21
21
25
31
31
32
32
65
65
66
67
0,7
0,7
0,7
0,8
4
6
9
15,0
22,0
28,0
114
114
119
21
21
21
31
31
32
81
81
85
0,8
0,8
1,0
4
6
9
12
21,3
26,9
33,7
42,4
80
80
82
84
21
21
21
25
31
31
32
32
65
65
66
67
0,7
0,7
0,7
0,8
4
6
9
12
21,3
26,9
33,7
42,4
80
80
82
84
21
21
21
25
31
31
32
32
65
65
66
67
0,7
0,7
0,7
0,8
4
6
9
15,0
22,0
28,0
114
114
119
21
21
21
31
31
32
81
81
85
0,8
0,8
1,0
4
6
9
12
21,3
26,9
33,7
42,4
80
80
82
84
21
21
21
25
31
31
32
32
65
65
66
67
0,7
0,7
0,7
0,8
4
6
9
12
21,3
26,9
33,7
42,4
80
80
82
84
21
21
21
25
31
31
32
32
65
65
66
67
0,7
0,7
0,7
0,8
4
6
9
15,0
22,0
28,0
114
114
119
21
21
21
31
31
32
81
81
85
0,8
0,8
1,0
TERMOVAR can be delivered factory mounted in any position and with other temperatures on request
Availabe with NPT-threads
POSITION 2
POSITION 3
TERMOVAR LOADING VALVE
ORDERING DATA FOR TERMOVAR CAST IRON VALVES
Order No. Type
Kvs
A mm
4140
17
48,3
TERMOVAR 40 45°C Rp 1½"
4150
TERMOVAR 50 45°C Rp 2"
21
60,3
B mm
127
135
C mm
40
48
D mm
48
65
E mm
100
105
Weight kg
2,8
4,2
4240
4250
TERMOVAR 40 55°C Rp 1½"
TERMOVAR 50 55°C Rp 2"
17
21
48,3
60,3
127
135
40
48
48
65
100
105
2,8
4,2
4340
4350
TERMOVAR 40 61°C Rp 1½"
TERMOVAR 50 61°C Rp 2"
17
21
48,3
60,3
127
135
40
48
48
65
100
105
2,8
4,2
4440
4450
TERMOVAR 40 72°C Rp 1½"
TERMOVAR 50 72°C Rp 2"
17
21
48,3
60,3
127
135
40
48
48
65
100
105
2,8
4,2
4540
4550
TERMOVAR 40 80°C Rp 1½"
TERMOVAR 50 80°C Rp 2"
17
21
48,3
60,3
127
135
40
48
48
65
100
105
2,8
4,2
TERMOVAR can be delivered factory mounted in any position and with other temperatures on request
POSITION 1
POSITION 2
B
A
B
A
E
2
1
2
E
3
1
3
C
D
C
D
POSITION 3
E
A
1
B
3
P
2
C
D
INSTALLATION
INSTALLATION POSITION 1:
TERMOVAR
TERMOVAR 45°C - 55°C - 61°C - 72°C or 80°C
INSTALLATION:
TERMOVAR installed in the supply water pipe.
FUNCTION:
When the solid-fuel boiler has reached the selected temperature the thermal valve
opens. Supply water from the boiler is loaded to the storage tank. Return water
from the storage tank is mixed with supply water before flowing back to the boiler. The loading continues as long as the boiler is being fired. A balancing valve
is to be installed between boiler and loading valve.
TERMOBAC:
When the loading of the storage tank is completed the circulation pump will shut
off. The TERMOBAC will now prevent self-circulation from storage tank back to
boiler. In case of power or pump failure the TERMOBAC will open automatically
for self-circulation.
LOADING PUMP:
TERMOBAC
The loading pump should be controlled by a thermostat which measures boiler
temperature. The pump will start when the boiler is at operating temperature and
stop when the boiler drops below this temperature.
INSTALLATION POSITION 2:
TERMOVAR 45°C - 55°C - 61°C - 72°C or 80°C
INSTALLATION:
TERMOVAR installed in the return water pipe.
FUNCTION:
When the solid-fuel boiler has reached the selected temperature the thermal valve
opens. Supply water from the boiler is loaded to the storage tank. Return water
from the storage tank is mixed with supply water before flowing back to the boiler. The loading continues as long as the boiler is being fired. A balancing valve
is to be installed between boiler and loading valve.
LOADING PUMP:
The loading pump should be controlled by a thermostat which measures boiler
temperature. The pump will start when the boiler is at operating temperature and
stop when the boiler drops below this temperature.
TERMOVAR
INSTALLATION POSITION 3:
TERMOVAR 45°C - 55°C - 61°C - 72°C or 80°C
INSTALLATION:
TERMOVAR installed between supply water pipe and return water pipe.
FUNCTION:
When the solid-fuel boiler has reached the selected temperature the thermal valve
opens. Supply water from the boiler is loaded to the storage tank. Return water
from the storage tank is mixed with supply water before flowing back to the boi-
TERMOVAR
ler. The loading continues as long as the boiler is being fired. A balancing valve
is to be installed between boiler and loading valve.
TERMOBAC:
When the loading of the storage tank is completed the circulation pump will shut
off. The TERMOBAC will now prevent self-circulation from storage tank back to
boiler. In case of power or pump failure the TERMOBAC will open automatically
for self-circulation.
LOADING PUMP:
The loading pump should be controlled by a thermostat that measures flue-gas
TERMOBAC
temperature. The pump will start when the boiler is fired up and stop when it has
altefur 09.02
ceased to fire.
TERMOVAR LG
TECHNICAL DATA
Temperature range, LGE
Opening temperature, LGT
Flow through
Max. operating temperature
Max. operating pressure
Length
Weight
0 – 90°C, stepless
45°C, 55°C, 61°C, 72°C or 80°C, fixed
Grundfos UPS 25-60 pump 2600 l/h
Grundfos UPS 25-80 pump 3700 l/h
110°C
1.0 MPa (10 bar)
46 cm
6.0 kg
TERMOVAR LG is a loading kit designed to keep a high boiler temperature in a solid fuel installation with a storage tank. TERMOVAR LG
ensures a minimum return-water temperature into the heating boiler,
which increases efficiency, prevents tarring and considerably prolongs the lifetime of the solid fuel boiler. After firing a backflow
preventer prevents recirculation.
TERMOVAR LG is available in two designs:
LGE equipped with a constant temperature control to set the return
temperature of the boiler steplessly 0 – 90°C.
LGT with a thermally operated valve with a fixed temperature of
45°C, 55°C, 61°C, 72°C or 80°C .
TERMOMIX LG can be delivered customised.
TERMOVAR LG INCLUDES
1. LGE with AUTOMIX CT constant temperature control or LGT with
TERMOVAR 40 A thermally operated valve
2. Grundfos UPS 25-60 pump
3. TERMOMIX D 40 A 3-way mixing valve Kvs15 (LGE)
4. TERMOBAC backflow preventer G 1½”/Rp 1¼” /G 1½”
5. Connections 2 pcs Rp 1½” / Rp 1½”
6. Ball valves 3 pcs, Rp 1”, Rp 1¼” or 28 mm
7. Bush G 1¼” /Rp ½”
8. Thermometer 0 – 120°C Rp ½”
9. EPDM-sealings 7 pcs 1½” - 44 x 27 x 2 mm
TERMOVAR LG LOADING KIT has several advantages:
• The heating boiler quickly reaches a high and even operating
temperature
• The simple installation saves on labor charges
• Can be installed on the right- or left-hand side of the boiler
• Can be customised
• Can be used with different pump makes and capacities
LK ACASO AB
Box 634
SE-521 21 Falköping
Tel: +46 515 107 50
Fax: +46 515 590 30
E-mail: info@lkacaso.se
Internet: www.lkacaso.se
• Service friendly. All parts can be changed without draining the
system
TERMOVAR LGE LGT
ORDERING DATA
Order No. Type
5125
TERMOVAR
5128
TERMOVAR
5132
TERMOVAR
5225-45
TERMOVAR
5228-45
TERMOVAR
5232-45
TERMOVAR
5225-55
TERMOVAR
5228-55
TERMOVAR
5232-55
TERMOVAR
5225-61
TERMOVAR
5228-61
TERMOVAR
5232-61
TERMOVAR
LGE 25 0-90ºC
LGE 28 0-90ºC
LGE 32 0-90ºC
LGT 25 45ºC
LGT 28 45ºC
LGT 32 45ºC
LGT 25 55ºC
LGT 28 55ºC
LGT 32 55ºC
LGT 25 61ºC
LGT 28 61ºC
LGT 32 61ºC
loading
loading
loading
loading
loading
loading
loading
loading
loading
loading
loading
loading
kit
kit
kit
kit
kit
kit
kit
kit
kit
kit
kit
kit
Grundfos UPS 25-60
Grundfos UPS 25-80
6
5
5
4
4
3
3
2
2
1
1
0
1
2
3
4
0
0,5
1,0
1,5
2,0
2,5
3,0
Other temperatures on request
Available without pump and/or backflow preventer
TERMOVAR LGE
altefur 09.02
TERMOVAR LGT
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising