WT1800 Product Tutorial

WT1800 Product Tutorial
WT1800
Product Tutorial
WT1800
PRECISION POWER ANALYZER
Product Tutorial
Page | 1
WT1800
Product Tutorial
Page | 2
WT1800
Product Tutorial
WT1800 PRODUCT TUTORIAL
Table of Contents:
A.) Overview & Objectives ...………………………………………
B.) Power Meter Connections …..…………………………………
C.) Basic Setup for Power Measurement
Initialize Settings ……………………………………………
Setting Wiring ………………………………………………
Setting Ranges ……………………………………………..
Setting Numeric Display Items ……………………………
Setting Crest Factor ………………………………………..
Setting Update Rate ………………………………………..
Page Function ……………………………………………..
Wave Display .…………………………………… ………..
Other Types of Displays ……………………………………
Trend Display ……………………………………….
Split Display …………………………………………..
LCD ON/OFF …………………………………………
5
5
6
6
7
8
8
9
9
9
10
10
11
11
D.) Harmonic Measurements
Harmonic Setup ……………………………………………… 12
Single & Dual List Display ………………………………….. 12
Basic Numeric Display ………………………………………. 12
Bar Graph Display…………………………………………… 13
Vector Display ……………………………………………….. 13
E.) Motor Set ………………………………………………………… 14
F.) Auxiliary Input ………………………………………………….. 15
G.) Delta Measurements
Set up and Applications ………………………………….…. 17
H.) Line Filter ………………………………………………………. 17
Page | 3
WT1800
Product Tutorial
I.) Frequency Filter ……………………………………………….. 17
J.) Integrator Function
Integrator Modes & Measurement Functions ……………. 18
Normal Mode ……………………………………………….. 19
K.) Store Function
Saving Data to Memory ……………………………………. 20
L.) User Defined Functions
Set up and Applications ……………………………………
21
M.) User Defined Event …………………………………………… 21
N.) D-A Output Function …………………………………………… 23
Page | 4
WT1800
Product Tutorial
WT1800 POWER ANALYZER PRODUCT TUTORIAL
A.) OVERVIEW & OBJECTIVES
The following is a basic demo procedure for the WT1800 Power Analyzer. This demo uses
the power meter’s own power supply for the load. The demo can easily be done in a
conference room or lab without having to hook up to the customer’s load.
B.) POWER METER CONNECTION
Measuring consumption power of the WT1800 Power analyzer
1. Connect the Power Meter using the load cord. Plug the Banana plugs into the Voltage
input terminals of Element # 1. Connect the Spade lugs to the Current terminals of
element # 1. Make sure all connections are tight.
2. Plug the power meter power cord into the load cord. Plug in the load cord.
3. Turn on the power meter.
Connect to 120 V 60
Hz Power Source
Plug Power Cord from
WT1800 Power Analyzer
into Load Cord.
Plug the Banana plugs into the Voltage
input terminals.
Connect the Spade lugs to the Current
terminals.
Page | 5
Connect Spade Lugs to
CURRENT Terminals
Connect Banana Plug to
VOLTAGE Terminals
WT1800
Product Tutorial
C.) BASIC SETUP FOR POWER MEASUREMENT
INITIALIZE SETTINGS
(Manual Chapter 20.2)
1.
Before you start your demo, you may
want to Initialize the settings to make sure it
was not left in an unknown mode or some
functions left on that may interfere with your
demo.
2.
Press [UTILITY] button.
3.
Press Initialize Settings Soft Key.
4.
Press Left Arrow Key to select OK.
5.
Press [SET] button.
SETTING WIRING
(Manual Chapter 1)
1. Press the [WIRING] button. Press the Wiring Soft Key
2. Press Left/Right arrow keys to highlight Element 1.
3. Press the Blue [SET] button. Press the Blue Down Arrow
key to highlight 3P4W.
4. Press the Blue [SET] button to select the 3P4W-wiring
configuration. Element lights 1,2 & 3 will turn ON.
5. Press [ESC] button to clear the menu.
6. NOTE for this Demo we will use the 3P4W wiring even
though we are only using single phase on Element #1. This
will allow you to demo some of the other functions later on
in the demo.
Page | 6
WT1800
Product Tutorial
SETTING RANGES
•
•
•
•
•
•
•
•
•
•
Page | 7
(Manual Chapter 1)
Press Voltage Up/Down arrow key to select Voltage ranges of
15/30/60/100/150/300/600/1000 Volts. For this demo set Voltage Range to 150 V.
Press Current Up/Down arrow key to select Current ranges of
10/20/50/100/200/500mA/1/2/5 Amps for Elements 1, 2 and 3. For this demo use
500 mA or 1 A range.
External Current Sensor Range Setting: Press [EXT SENSOR] button.
Press Current Up/Down arrow key to select Sensor ranges of 50/100/200/mV
1/2/5/10 Volts.
Sensor Scaling: Press [SHIFT] [EXT SENSOR] button, Sensor Ratio.
Use the Cursor Arrow keys to set the numeric scaling factor in mV/A. Press [EXT
SENSOR] button to exit back to Current Range settings.
The WT1800 offers a new Auto Range feature to improve speed of range change.
Press [CONFIG] button for either Voltage or Current. Press the Up/Down Arrow
keys to select the Upper Limit of the Auto Range search. Press [SET] button.
Press the Up/Down Arrow keys to select the Lower Limit of the Auto Range search.
Press [SET] button. Press [ESC] button to exit the menu.
Press [AUTO] button for Auto Range.
WT1800
Product Tutorial
SETTING NUMERIC DISPLAY ITEMS
•
•
•
•
•
•
•
•
•
•
•
•
(Manual Chapter 6)
Press [NUMERIC] display button. The default is 4 numeric items. Continue
Pressing [NUMERIC] will change from 4 items, to 8, to 16 etc.
Press [FORM] button. This is another way to select the number of Numeric Items to
be displayed. Press the Soft Keys to choose 4 items; 8 items; 16 items etc.
For this demo start by setting Numeric Form to 8 items. Press [ESC] to clear
Numeric Form menu.
There are two ways to select the Numeric Display items.
Using the ITEM & ELEMENT quick select function keys.
Select From the [ITEM] menu.
Press the UP Arrow button to highlight measurement item Urms1.
Press [U/I/P] button to see how the measurement item is changed. Try the other Item
Function keys and the [ELEMENT] key.
Press [U/I MODE] button. This changes the Mode from RMS to Mean (mn), DC
(dc), Real Mean (rmn) and AC (ac).
Press [ITEM] button. First Press Item No. Soft Key. Use the Cursor Arrow keys to
highlight the Item Number to be changed.
Press Function Soft Key to display the complete Item List. Use the Cursor Arrow
keys to highlight the measurement item. Press [SET] to select the item.
Press [ESC] to clear menu.
SETTING CREST FACTOR
(Manual Chapter 1)
• Press [UTILITY] button.
• Press System Config Soft Key. Select CF3 or CF6 with bottom Soft Key.
• NOTE: When selecting CF6, the Voltage and Current Ranges are one-half the
standard ranges at CF3.
Page | 8
WT1800
Product Tutorial
SETTING UPDATE RATE
•
•
•
•
•
Press [UPDATE RATE] button.
Press Soft Keys to change Update Rate from 50 msec to 20 sec.
Press the Fast Soft Key for a faster Update as displayed.
Press the Slow Soft Key for a slower Update as displayed.
Press the Current Rate Soft Key and with the Up/Down Arrow keys select the
Update from the menu. Highlight the Value then Press [SET].
PAGE FUNCTION
•
•
•
•
•
•
•
•
•
•
•
•
•
Page | 9
(Manual Chapter 6)
Press [PAGE Down] key to select twelve pages of different Display configurations.
Note the Default Display for the 3P 4W Wiring Configuration.
Use the DISPLAY ITEM & ELEMENT keys to set up the display items for each
page if you want something different than the default settings.
SETTING WAVE DISPLAY
•
•
(Manual Chapter 1)
(Manual Chapter 9)
Press [WAVE] display button.
Press [ITEM] display button. Press ALL OFF Soft Key. Use Up/Down Arrow
keys to select the waveform for display. Highlight the Waveform Number and Press
[SET]. The waveforms will be displayed for the checked items.
For this demo select U1 and I1 for display.
Press [ESC] key to clear menu.
Press [FORM] display button. This lets you configure various waveform display
functions using the menu and Soft Keys.
Format: Single; Dual; Triad; Quad; Hexa
Time/div: Use Up/Down Arrow keys to change time.
Trigger Settings: Auto/Normal; Source; Slope; Level
Display Settings: Interpolate; Graticule; Scale Value; Wave Label.
Wave Mapping: Auto; Fixed; User
Press [ESC] key to clear the menu.
NOTE: There are some restrictions on Time/Div setting and Update Rate. This is all
automatic.
WT1800
Product Tutorial
SETTING OTHER TYPE OF DISPLAYS
•
•
Press [OTHER] display button.
Using the Others Menu and Soft Keys you can select various display configurations.
TREND DISPLAY:
(Manual Chapter 10)
• Press [OTHER] display button, and Trend Soft Key.
• Press [FORM] button. Use the Soft Keys to select Form as Single, Dual, Triad, or
Quad. Select Dual or Triad for this demo. Use Soft Key to select Time/Div. For this
Demo set at 10 Sec.
• Press [ITEM] button. With the Arrow key, highlight T1 and Press [SET].
Set up the menu as shown below to Trend Volts, Amps & Watts.
•
Press [ESC] to clear menu and go back to Trend Display.
Page | 10
WT1800
Product Tutorial
SPLIT DISPLAYS
( Manual Chapter 13)
• Press [OTHER] button.
• Press the Soft Keys to select the different Split Screen Displays.
• Pressing [ITEM] in Split Screen mode will select the setup menu for top display
function, such as Numeric.
• Pressing [FORM] button in split Screen mode will select the Form setup menu for the
top display. You can select the number of items for the top display group.
• Press [ESC] to clear menu.
DISPLAY ON/OFF
(Manual Section ?)
• This new function has been added to the WT1800. Press [UTILITY] button. Press
System Config Soft Key, then LCD Soft Key. Press LCD Turn OFF Soft Key.
Press ANY button on the front panel turn the LCD back ON.
• LCD Auto OFF is also available. Press Auto OFF Soft Key to select OFF/ON. Set
Auto OFF Time from 1 min to 60 min.
• Press [ESC] to clear menus.
Page | 11
WT1800
Product Tutorial
D.) HARMONIC MEASUREMENTS
•
(Manual, Chapter 2)
Harmonic measurements and Normal measurements are made simultaneously in the
WT1800. There is not a Harmonic Mode and Normal Mode selection like in the
WT1600, older WT and PZ Series Power Analyzers. Requires Option /G5 or /G6
HARMONIC SETUP:
• First setup the Harmonic measurement functions
• Press [HRM SET]. Press Element Settings Soft Key. Set each Element to either Hrm1
or Hrm2. Press [ESC] to clear this menu.
• Next set the PLL Source; Min & Max Order; and THD Formula.
• The Max Order sets the number of Harmonic Orders over which to calculate the THD.
As an example a specification may call for calculating THD over 50 Orders.
• Selecting THD Formula: Press THD Formula Soft Key.
• UL & CSA applications typically use 1/Total as the mathematical formula.
• IEC applications use 1/Fundamental as the mathematical formula.
HARMONIC LIST DISPLAY:
• Press [NUMERIC] button for basic Numeric display. Display 8 Items
• Press [FORM] button then select Hrm List Single or Dual Soft Key. Press [ESC] to
clear the Form menu. This is a quick and easy way to show all the harmonic data.
• Press [PAGE Down] to view all the harmonic data
BASIC NUMERIC DISPLAY:
• Press [NUMERIC] button for basic Numeric display.
• Press [FORM] button then select 4 Items, 8 Items, or 16 Items Numeric display.
• Press [ITEM] button. Press Function Soft Key. Select Harmonics (k), then press Left
Arrow to select the measurement item. Press [SET].
• Press Order Soft Key. Press Up Arrow Cursor button to select Order 3.
Page | 12
WT1800
Product Tutorial
BAR GRAPH DISPLAY
(Manual Chapter 11)
• Press [OTHERS] button and Select Bar as the display type.
• Press [FORM] button. From the menu select type of display such as Single, Dual or
Triad. Select number of Harmonic Orders to display by using the Start Order and End
Order. Use this as a “Zoom” function for the Bar Display.
• Press [ITEM] button. From the menu select Function ( U, I, P, etc) to display as a Bar
Graph. Use the Bar Item No. to select where to display a selected Function. Press
[ESC] to clear the menu.
VECTOR DISPLAY:
(Manual Chapter 12)
• Press [OTHER] button and Vector Soft Key.
• Press [FORM] button. Press Object Soft Key. In this demo example the Object can be
set to Element 1 or “Sigma A.”
• Press [ITEM] button.
• Press Mag Soft Key. Press Mag Soft Key twice to highlight both U Mag and I Mag.
Press Left Arrow Cursor Key to highlight the most significant digit. Use UP Arrow
Cursor Key to increase Mag to 2 for this demo.
• Press [ESC] to clear menu.
• Press [FORM] button. You can select a Single or Dual Vector Display with Dual
Harmonics option, /G6.
Page | 13
WT1800
Product Tutorial
E.) MOTOR SETTINGS
(Manual Section 3)
Press Shift [SCALING] ( Motor/AUX SET)
• This is where the various parameters are set to match the Speed and Torque sensors
being used by the customer.
•
•
•
•
•
In Numeric display mode, Press [ITEM]and select Function Soft Key.
Select Item No. Soft Key and choose a display position for the measured item.
Press Function Soft Key.
In the Function menu use Down Arrow to select Motor. Press Left Arrow then highlight
Speed. Press [SET]
Repeat to display other items like Torque, Pm (Mechanical Power), etc.
Page | 14
WT1800
Product Tutorial
F.) AUXILIARY SETTINGS
(Manual Section 4)
Press Shift [SCALING] ( Motor/AUX SET)
• This is where the various parameters are set for the Auxiliary inputs.
Use the Arrow Keys to move around the menu. Highlight the particular function, such as
Range, and Press [SET] button to select. Use Arrow Key to highlight the desired Range and
Press [SET] button to select.
You can assign a Name and Unit for each of the Aux Inputs. Use the Arroe Keys to move to
the desired function and Press [SET] to display the keyboard.
Page | 15
WT1800
Product Tutorial
To Display the AUX Measurements, Press [ITEM] button. Then Press [Function] Soft
Key and highlight Aux and Press [SET] button. Then select Aux1 and or Aux2 to be
displayed. The Name and Units will be displayed.
Page | 16
WT1800
Product Tutorial
G.) DELTA MEASUREMENT
•
•
•
•
•
•
•
•
•
(Manual Section 1.10)
NOTE: This measurement requires 3P3W, 3V3A or 3P4W wiring method with three
phases of Voltage and Current applied to the input terminals.
Press [WIRING] button and ∆ Measure Soft Key.
Press [SET] button to select Delta Measure Mode. Press [SET] button to select from
rms; mean; dc; r-mean or ac voltage mode.
Press [ESC] to exit this menu.
In Numeric display mode, Press [ITEM]and select Function Soft Key.
Select Item No. Soft Key and choose a display position for the measured item.
Press Function Soft Key.
In the Function menu use Down Arrow to select ∆ Measure. Press Left Arrow then
∆U1. Press [SET]
Repeat to display ∆U2, ∆U3 and ∆I.
H.) LINE FILTER
(Manual Section 1.13 )
• Press [LINE FILTER] button.
• Press Element Soft Key to Select OFF or ON.
• Use the Arrow Keys to select the Cutoff frequency. The WT1600 uses a new Digital
Filter with selectable filters of 0.1kHz to 100kHz in o.1 kHz steps.
• In addition there is a 300kHz and 1 MHz Analog Filter. These are selectable by
Pressing Up Arrow after the 100.0kHz selection.
I.) FREQUENCY FILTER
(Manual Section 1.14)
• Press SHIFT [LINE FILTER] FREQ FILTER button.
• Press Element Soft Key to Select OFF, 100Hz or 1kHz.
• The 100Hz filter is typically used for 50/60 Hz Line Frequencies.
• The 1kHz filter is typically used for 400/800 Hz Aircraft applications.
Page | 17
WT1800
Product Tutorial
J.) INTEGRATOR FUNCTIONS
(Manual Section 8)
• Set Numeric Display as shown below.
WP = Watt Hours
q = Ampere Hours
WS = Volt-Amp Hours
WQ = VAR Hours
Time = Integration Run Time
•
First set up the Integration Measurement items to be displayed.
• Quick set method: In the Numeric Display Mode, use the Arrow key to select the
position on the screen to display the measurement item. In the ITEM & ELEMENT
section, Press [WP/q/TIME] button.
• Press [ELEMENT] button to select the appropriate element.
• Example Select WP1 and TIME1.
• For other items select from the Item menu. In the Numeric Display Mode, Press
[ITEM] button and Function Soft Key. Press Down Arrow key to highlight Integrate.
Press Left Arrow key and highlight a measurement item. Example WP for Watt Hours.
Press [SET].
Page | 18
WT1800
Product Tutorial
•
STARTING INTEGRATION
(Manual Section 8)
There are Four different Integration Modes. Press [INTG] button. Press Intg Set Soft
Key. Select the Mode using the Soft Key. Normal; Continuous; R-Normal; RContinuous. Select Normal.
•
•
•
•
•
With Mode [Normal], Press Integ Timer Soft Key. Set an integration time. Press
Left Arrow key to highlight Minute field. Press [SET] button. Use Up/Down Arrow
Key to set an integration time. Example set for 5 Min. Press [ESC].
Press [INTEG] button.
Press Start Soft Key to start Integration function. Once Integration is started, you
cannot change any of the settings. Try changing Range or any of the other functions.
The front panel is locked up!
Press Stop Soft Key to stop Integration function. Note that Timer and Integration
functions stop updating. Press Start Soft Key again and note the Timer and
Integration functions start again. This is more like a Pause condition. Settings cannot
be changed.
To Quit or End Integration function, Press Stop then Press Reset Soft Keys. This
stops the Timer, and now settings can be changed. Quit Integration before
continuing.
Page | 19
WT1800
Product Tutorial
K.) STORE FUNCTION
•
•
•
•
•
•
•
•
•
( Manual Section 15)
Press [SHIFT] [STORE START] (Store Set).
Press Control Settings Soft Key. Press Store Mode Soft Key to select the different
Store functions:
o Manual: Select Manual for the demo exercise
o Real Time:
o Integ Sync:
o Event:
o Single Shot:
Set the Store Count by using the UP/DOWN Arrow Keys to set the number.
Press Interval Soft Key. With the Interval time set to all zeros, the data will be stored at
the Update Rate setting of the unit. Otherwise you can set the storage interval for
Hour/Minute/Second.
Press Item Settings Soft Key. Next Press Soft Key for Displayed Numeric Items OR
Selected Items. For Selected Items, Press Items Soft Key. Use the Arrow Keys to
navigate around the Item Settings Menu. To select an item to store, move the cursor to
highlight the item and Press [SET].
Press [ESC] to return to the Store Set Menu.
Press File Settings Soft Key. Here you can set up file names and other store functions.
Press [STORE START] button to start the store function.
The store memory must be reset before another Store function can be performed. Press
SHIFT [STORE STOP] ( STORE RESET) to reset memory.
Page | 20
WT1800
Product Tutorial
L.) USER DEFINED FUNCTIONS
•
•
•
•
•
•
The WT1800 includes a powerful User Defined Math Function as standard. Twenty
Math Functions can be assigned for special analysis and computation.
Press [MEASURE] button. Press User Defined Soft Key.
Select User Defined F1 – F5. There are many useful Preset, Default Math functions
already installed
Function 1 is Average Active Power. Press [SET] to turn the function ON. Note there
is now a Name Field.
Press [ITEM] button. Select an Item No. for a position to display the data. Press
Function Soft Key. Select User Func and F1.
Press [INTG] and Start Soft Key. The Average Active Power uses the Integrator to
make the calculations.
M.) USER DEFINED EVENT FUNCTION
•
•
•
•
•
•
•
(Manual Section 7.1)
(Manual Section 7.2)
The WT1800 includes a New User Defined Event Function as standard. Eight Event
Trigger Functions can be set for TRUE/FALSE conditions.
Press [MEASURE] button. Press User Event Soft Key.
Use the Arrow keys to step through the Menu settings. Highlight the Function and Press
[SET].
You can select Any of the Measured Items to use as one of the Event functions.
Highlight a measurement function and Press [Set].
Set the other functions such as Element and Limits.
Press [ESC] to exit the menu.
Saving the Event Data
• Press [SHIFT] [STORE START] (Store Set).
• Press Control Settings Soft Key. Press Store Mode Soft Key then Event Soft Key.
• Set up the Store conditions as covered in Section K.
• Press [STORE START] button. This will Arm the Store function. The Store Light will
blink until an event condition is met. Only Data that is outside the Event Conditions will
be saved.
Page | 21
WT1800
Product Tutorial
Page | 22
WT1800
Product Tutorial
N.) D/A OUTPUT FUNCTION
•
•
•
•
( Manual Chapter 9)
Press [UTILITY] button. Press D/A Output Items Soft Key.
From the D/A Output Items menu, set up the Function and Element for each D/A
Channel.
Example, use the Left Arrow key to highlight the Function for Channel 4. Press [SET].
o Down Arrow to Power. Press [SET].
o Down Arrow to S. Press [SET].
o Use Right Arrow to Highlight Element. Press [SET].
o Select an Element number. In this case select Element 1. Press [SET].
o Press [ESC] to clear menu.
Setting the D/A Zoom Function
o Use Right Arrow to Highlight Range Mode. Press [SET].
o Select Manual.
o Use Right Arrow to Highlight Max and Press [SET].
o Set the Max value for the measured signal. Example 75. Press [SET].
o Use Right Arrow to Highlight Min and Press [SET].
o Set the Min value for the measured signal. Exmple 0. Press [SET].
o Press [ESC] to clear menu.
Page | 23