IMPORTANT SAFETY INSTRUCTIONS......................................................................................................................1
PARTS & TOOLS....................................................................................................................................................3
SITE PREPARATION ..............................................................................................................................................6
INSTALLATION
• REMOTE M
OUNTING OF TURBINE WITH ACCESS UNDER BATH...............................................................7
• ELECTRICAL DIAGRAMS..............................................................................................................................16
• REMOTE M
OUNTING OF TURBINE WITHOUT ACCESS UNDER BATH......................................................17
CUTTING TEMPLATES: ELECTRONIC CONTROLS...................................................................................................24
1 800 463.2187
Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST)
Printed in Canada. Copyright © March 2017 BainUltra Inc. All rights reserved. 45200655
OPALIA COLLECTION
TM
INSTALLATION INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
•
OPALIA - inst allat io n
PERTAINING TO RISKS OF FIRE, ELECTROCUTION OR PERSONAL INJURY
SAVE THESE INSTRUCTIONS
THIS DOCUMENT SUPERCEDES THE INSTALLATION INSTRUCTION IN THE OWNER’S MANUAL.
WARNING
• Risk of hyperthermia; people using medication and/or having an adverse medical history should consult a physician
before using a Hydro-thermo massage® bathtub equipped with a heater.
•Risk of hyperthermia and possible drowning: do not use a Hydro-thermo massage® bathtub equipped with heater
immediately following strenuous exercise.
•Risk of fetal injury; pregnant or possibly pregnant women should consult a physician before using a Hydro-thermo
massage® bathtub equipped with a heater.
•Risk of accidental injury or drowning; do not use drugs or alcohol before or during the use of a Hydro-thermo massage®
bathtub equipped with a heater.
•Use this unit only for its intended purposes or as described in this manual. Use only accessories or devices recommended
by the manufacturer.
•Risk of hyperthermia and possible drowning. Check and adjust water temperature before use. Water temperature
exceeding 100ºF (38ºC) may be injurious to your health.
•To reduce the risk of injury, as with any other conventional bath, do not allow children or physically impaired people
to use this unit unless they are closely supervised at all times.
• To avoid injury, exercise care when entering or exiting the Thermomasseur®.
•The Geysair should always be connected to the hot water intake. If it is not the case, then, the Geysair should be deactivated via the bath control.
RISK OF ELECTRICAL SHOCK
• Disconnect electric power before servicing.
•Do not permit electrical appliances (hair dryer, lamp, telephone, radio, television, etc.) within 5’ (1,5 m) of the Thermomasseur®.
•Before using the Thermomasseur®, its installation should be completelay finished so that a bather cannot accidentally come
in contact with electrical components (turbine and power module).
• For indoor use only.
www.bainultra.com
Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.
1
OPALIA COLLECTION
TM
INSTALLATION INSTRUCTIONS
OPALIA - inst allat io n
IMPORTANT SAFETY INSTRUCTIONS (cont’d)
PERTAINING TO RISKS OF FIRE, ELECTROCUTION OR PERSONAL INJURY
READ AND FOLLOW ALL INSTRUCTIONS
•
SAVE THESE INSTRUCTIONS
THIS DOCUMENT SUPERCEDES THE INSTALLATION INSTRUCTION IN THE OWNER’S MANUAL.
ELECTRICAL CONNECTIONS:
• Never drop or insert objects into any openings.
•The Thermomasseur® must be connected only to a supply circuit that is protected by a 20 amp class A ground fault circuit
interrupter (GFCI). Optional therapies such as Chromotherapy and/or 2nd heated backrest and/or WarmTouchShell® must
be connected to a supply circuit that is protected by a 15 amp class A ground fault circuit interrupter (GFCI). This interrupter
is supplied by a certified electrician and must be tested on a regular basis in accordance with manufacturer’s instructions.
The GFCI ground must be connected. If defective, do not use the Thermomasseur®. Disconnect immediately and call a
certified electrician.
• Use 12 AWG (or greater) copper conductors that resist temperatures of at least 194ºF (90ºC).
• Canada only: for permanently connected units. A green-colored terminal (or a wire connector marked g., gr., ground
or grounding) is provided within the terminal compartment (not applicable if unit supplied with an electric plug).
To reduce the risk of electrocution, connect this terminal or connector to the grounding terminal of your electric service
or supply panel with conductor equivalent in size to the circuit conductors supplying the equipment and be 12 AWG
or more.
•All electrical connections must be carried out by a certified electrician and must respect federal, provincial/state,
and local building codes and regulations.
• Install in accordance with manufacturer’s installation instructions.
•For Geysair-equipped baths using remote turbine installation (not mounted on the bath), grounding continuity must be
tested between the bath grounding terminal
and the bath power supply. Failure to perform the grounding continuity
test could result in serious personal injury.
WATER LEAK TEST
•Once plumbing is fully installed and before beginning any other work, fill the ThermoMasseur® with water to overflow level
and wait 30 minutes. Check all plumbing hook-ups and bath for leaks. BainUltra® is not responsible for any water damage
caused by improper installation (see Warranty section).
2
1 800 463.2187
Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST)
Printed in Canada. Copyright © March 2017 BainUltra Inc. All rights reserved. 45200655
OPALIA COLLECTION
TM
INSTALLATION INSTRUCTIONS
STANDARD PARTS - PLUMBING
DESCRIPTION
A
OPALIA - inst allat io n
PARTS & TOOLS REQUIRED
A
QTY
Plated drain clicker
B
1
BStrainer
1
C
1
Rubber seal
D Tee PVC Drain shoe
1
E
1
Anchor set*
C
D
E
OPTIONAL PARTS - PLUMBING
DESCRIPTION
F
QTY
Brass drain shoe
1
G 4 in. brass tailpiece 1
H Nylon conic shaped seal for drain
1
I
Brass nut
2
J
Brass pipe 1-1/2” x 3” with flange
1
K
Nylon flat seal with flange
1
L
1-1/2” male threaded adaptor
1
F
L
K
J
I
H
OPTIONAL PART – PLUMBING*
ENSEMBLE ISLAND TUB DRAIN® (ITD)
•Makes installation and servicing easier
for removal of bath.
•Allows you to connect the bath drain
tailpiece to the plumbing pipe without
need for tightening to seal once the bath
is lowered to the floor.
G
•SET INCLUDES A CONIC SHAPED SEAL AND
A 6 IN. (15 CM) BRASS TAILPIECE.
* : REQUIRED WHEN NO ACCESS IS POSSIBLE
UNDER the BATH.
www.bainultra.com
Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.
3
OPALIA COLLECTION
TM
INSTALLATION INSTRUCTIONS
OPALIA - inst allat io n
PARTS & TOOLS REQUIRED
STANDARDS PARTS – FLOOR ANCHOR
DESCRIPTION
QTY
M Threaded anchor
2
N 1/2” Nut – 13 zinc
2
O 1/2” Flat washer
2
P
12
#10 X 1-1/2” Countersunk head screw
N
P
O
Q
M
Q Cover seals2
STANDARDS PARTS – THERMOMASSEUR®
DESCRIPTION
QTY
A Turbine
1
B
MiaPlus Control
1
C
MiaMulti® Control (option)
1
®
D 15’ extension cord
B
1
A
C
D
4
1 800 463.2187
Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST)
Printed in Canada. Copyright © March 2017 BainUltra Inc. All rights reserved. 45200655
OPALIA COLLECTION
TM
INSTALLATION INSTRUCTIONS
OPALIA - inst allat io n
PARTS & TOOLS REQUIRED
PARTS & TOOLS REQUIRED
Installation template
48-inch level
Measuring tape
Teflon tape
Caulking gun
Silicone
ABS & PVC Glue
Square/Phillips #2 Screwdriver
3/4” Ratchet
Adjustable clamps
www.bainultra.com
Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.
5
OPALIA COLLECTION
TM
INSTALLATION INSTRUCTIONS
OPALIA - inst allat io n
SITE PREPARATION
PLUMBING
•See faucet manufacturer’s specifications for zoning
and plan water supply location accordingly.
•Position drain according to bath’s technical specifications.
WARNING
• Baths from OpaliaTM collection cannot be drilled
for faucet installation. Faucets must be freestanding
or wall-mounted models.
1500 LB
(680 KG)
FLOOR
BEDDING
•Before installing, ensure that the floor underneath the bath can support 1500 lb (680 kg). The bath may sit directly
on the floor. No special bedding installation is recommended by manufacturer, the bathtub can sit directly on the floor. However, the bath can also sit on a concrete bedding. In that case, it is recommended to isolate the concrete between two plastic
sheets: one installed on the floor and the other under the bath.
SERVICE ACCESS AND VENTILATION
•A service access is necessary. Minimum dimensions are 22 in. x 18 in. (55 cm x 46 cm)
to properly reach all electrical components of the system.
•An air vent is necessary. Minimum dimensions are: 2 in. x 4 in. (5 cm x 10 cm)
to ensure proper functioning of the turbine.
There is a technical specification sheet for each BainUltra® ThermoMasseur® which includes information such as necessary
dimensions of site before installation.
If you do not already have the technical specifications, download it from the BainUltra® Web site at: bainultra.com
or call us at: 1 800 463-2187.
6
1 800 463.2187
Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST)
Printed in Canada. Copyright © March 2017 BainUltra Inc. All rights reserved. 45200655
OPALIA COLLECTION
TM
INSTALLATION INSTRUCTIONS
OPALIA - inst allat io n
REMOTE
PARTS & TOOLS
MOUNTING
REQUIRED
OF TURBINE WITH ACCESS UNDER BATH
PLUMBING – FLOOR LAYOUT FOR PIPES AND ACCESS
OPALIA 6938
NOTE : Please refer to the Installation Template provided with your OPALIA bath. However, if it is missing, please contact us
at 1-800-463-2187 to order it.
1
PLUMBING
HELPFUL TIP:
• Carefully place the tub
on its side, on a blanket
or a corrugated cardboard.
Measure &
Align (2x)
Anchor M
www.bainultra.com
Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.
7
OPALIA COLLECTION
TM
INSTALLATION INSTRUCTIONS
OPALIA - inst allat io n
REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH
A
STANDARD PARTS - PLUMBING
DESCRIPTION
B
QTY
A
Plated drain clicker1
B
Strainer1
C
Rubber seal1
D Tee PVC Drain shoe1
A
B
C
D
C
D
OPTIONAL PARTS - PLUMBING
DESCRIPTION
QTY
FTee Brass drain shoe1
G 4 in. brass tailpiece 1
H Nylon conic shaped seal for drain1
I
Brass nut1
J
Brass pipe 1-1/2” x 3” with flange1
K
Nylon flat seal with flange1
L
1-1/2” male threaded adaptor1
Flexible
Overflow Piping
(Factory installed)
F
G
L
8
1 800 463.2187
K
J
I
H
Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST)
Printed in Canada. Copyright © March 2017 BainUltra Inc. All rights reserved. 45200655
OPALIA COLLECTION
TM
INSTALLATION INSTRUCTIONS
2
OPALIA - inst allat io n
REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH
TURBINE & GEYSAIR INSTALLATION (FOR THERMOMASSEUR®)
Geysair Hose and
Back Flow Preventer
1-1/2 I.D. PVC AIR INTAKE PIPE
(«TIGERFLEX®» FLEXIBLE PVC)
1-1/2 I.D. ABS, PVC PIPE
(RIGID or «TIGERFLEX»)
& Fittings (not included)
Hot Water Supply
TURBINE REMOTE
MOUNTING
SEE STEP 7 page 13
WARNING
•Access to Geysair® backflow preventer is necessary for cleaning of the filter.
•Baths from Opalia™ collection cannot be drilled for faucet installation. Faucets must be freestanding
or wall-mounted models.
•Geysair component cannot be remote mounted. It must stay at original position, attached to bath.
Must never be unplugged.
3
ELECTRICAL WIRING OF OPTIONAL COMPONENTS
REMOTE MOUNTING
of CONTROL MODULES
SEE STEP 8 page 14
www.bainultra.com
Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.
9
OPALIA COLLECTION
TM
INSTALLATION INSTRUCTIONS
OPALIA - inst allat io n
REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH
4
BATH INSTALLATION - OPALIA 6938
HELPFUL TIPS:
•Carefully place the tub on its side,
on a blanket or a corrugated cardboard.
•To easily manipulate the bathtub
in a safe way during installation,
we recommend using moving straps.
Floor
anchor
M
Measure
& Align (2x)
WARNING
• Be sure the floor is leveled. Use shims as needed.
•Do not remove the protective plastic film on the tub
and place a drop-cloth in the tub during installation
to protect the acrylic.
• A
pply a bead of silicone around the perimeter
of the bath once on the floor.
• The tub must be securely anchored to floor.
• Connect the drain.
• Fix bath to floor by using washers «O» and nuts «N».
Floor
Surface
•Install the bath on anchors « M » previously
screwed to floor. Remove exceeding silicone.
• Place cover seals «Q» over openings.
1“ Minimum
N
O
Q
M
10 1 800 463.2187
Anchor
Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST)
Printed in Canada. Copyright © March 2017 BainUltra Inc. All rights reserved. 45200655
OPALIA COLLECTION
TM
INSTALLATION INSTRUCTIONS
5
ELECTRONIC CONTROL INSTALLATION – MIAPLUS® & MIAMULTI® (OPTIONAL) LOCATION
LOCATION: Determine the most convenient location, on the wall close to tub. Peel off the protective film of sticker
behind the control. You can add a silicone bead to secure to the wall.
WARNING
•Baths from Opalia collection cannot be drilled for faucet installation. Faucets must be freestanding or wall-mounted models.
TM
• DRILLING OF WALL: Refer to the Cutting Template on page 24 for the location and diameter of the holes.
TOOLS REQUIRED
Jig saw with fine cut blade
Drill
1/4 in. drill bit
TOUCH PAD INSTALLATION
Push wiring through drilled holes.
Remove protective film from watertight seal.
Secure to the wall with permanent waterproof
sealant (mold-free clear silicone for bathrooms).
Secure temporarily with a tape for about 24 h.
5
ELECTRONIC CONTROL INSTALLATION – DOT
TOOLS REQUIRED
7/8 in. Hole saw
Drill
TOUCH PAD INSTALLATION
DOT WarmTouchShell® (WTS)
Push wiring through drilled holes.
Remove protective film from watertight seal.
Secure to the wall with permanent waterproof
sealant (mold-free clear silicone for bathrooms).
Secure temporarily with a tape for about 24 h.
DOT Chromatherapy (LED)
WARNING
• If the control is not factory installed, you will find it attached to the turbine, or to the electronic control modules.
www.bainultra.com
Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.
11 OPALIA - inst allat io n
REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH
OPALIA COLLECTION
TM
INSTALLATION INSTRUCTIONS
OPALIA - inst allat io n
REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH
6
REMOTE MOUNTING OF TURBINE
Bottom of door
hen located in an
W
enclosed location.
1”
Floor
WARNING
•Choose a location for the turbine with the shortest possible distance from the Thermomasseur® bath, no more
than 15 ft. (4,6m), and a maximum of six elbow directional changes to ensure system performance. It can be under
the floor, in a closet or any other place that can hide the turbine and if needed optional modules. Easy access must
remain possible at all time and sufficient air ventilation is necessary for turbine.
•A service access is necessary. Minimum dimensions are 22 in. x 18 in. (55 cm x 46 cm) to properly reach all electrical
components of the system.
• An air vent is necessary. Minimum dimensions are: 2 in. x 4 in. (5 cm x 10 cm) to ensure proper functioning of the turbine.
•Geysair® cannot be remotely installed.
12 1 800 463.2187
Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST)
Printed in Canada. Copyright © March 2017 BainUltra Inc. All rights reserved. 45200655
OPALIA COLLECTION
TM
INSTALLATION INSTRUCTIONS
7
OPALIA - inst allat io n
REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH
REMOTE MOUNTING OF TURBINE - AIR PIPE (THERMOMASSEUR®)
1-1/2 I.D. ABS, PVC PIPE
(RIGID or «TIGERFLEX»)
& Fittings (not included)
7
REMOTE MOUNTING OF TURBINE - ELECTRICAL CONNECTIONS (THERMOMASSEUR®)
• See page 16 for electrical diagram
GEYSAIR
EXTENSION CORD
(If required for longer distance,
contact BainUltra for ordering)
GEYSAIR CONNECTION
TO GFCI Outlet
United States
Junction box
Canada
WARNING
•For Geysair® equipped baths using remote turbine installation (not mounted on the bath), grounding continuity
must be tested between the bath grounding terminal
and the bath power supply.
Failure to perform the grounding continuity test could result in serious personal injury.
www.bainultra.com
Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.
13 OPALIA COLLECTION
TM
INSTALLATION INSTRUCTIONS
OPALIA - inst allat io n
PARTS & TOOLS REQUIRED
8
REMOTE MOUNTING OF TURBINE – ELECTRICAL CONNECTIONS OF OPTIONAL THERAPIES
• See page 16 for electrical diagram.
Match the colors of the
plug-in cables with those
of the turbine terminals
E
D
A: 2nd Heated Backrest
B: Chromatherapy (LED)
C: MiaPlus®
C
D: MiaMulti (Option)
®
E : AromaCloud®
B
A
Junction box
Canada
TO GFCI Outlet
United States
Junction box
Canada
TO GFCI Outlet
United States
WARNING
•Electrical outlet must be installed by a certified electrician. Installation must be conducted in accordance with all local,
provincial/state, and federal building/electrical codes and regulation.
•Connect electrical supply only after all low voltage wiring is properly installed on turbine.
•If you did not follow this last step, shut off and then restart your home’s circuit breaker.
• Turbine and air pipe should be clear of building materials and wiring.
14 1 800 463.2187
Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST)
Printed in Canada. Copyright © March 2017 BainUltra Inc. All rights reserved. 45200655
OPALIA COLLECTION
TM
REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH
8
REMOTE MOUNTING OF OPTIONAL THERAPIES (TUB ONLY) – ELECTRICAL CONNECTIONS
• See page 16 for electrical diagram.
E
A : WarmTouchShell®
B: Chromatherapy (LED)
C : DOT WarmTouchShell®
D
C
D : DOT Chromatherapy
E : AromaCloud®
B
A
C
Junction box
Canada
DOT WarmTouchShell® (WTS)
D
Junction box
Canada
TO GFCI Outlet
United States
TO GFCI Outlet
United States
DOT Chromatherapy (DEL)
www.bainultra.com
Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.
15 OPALIA - inst allat io n
INSTALLATION INSTRUCTIONS
OPALIA COLLECTION
TM
INSTALLATION INSTRUCTIONS
OPALIA - inst allat io n
PARTS
REMOTE
& TOOLS
MOUNTING
REQUIRED
OF TURBINE WITH ACCESS UNDER BATH
ELECTRICAL DIAGRAM – 20A THERMOMASSEUR® et 15A THERAPY
15A CIRCUIT
15A CIRCUIT
20A CIRCUIT
NEUTRAL N
L LOAD
NEUTRAL N NEUTRAL N
L LOAD
L LOAD
GROUND
FAULT CIRCUIT
INTERRUPTERS
GROUND
GROUND
FAULT CIRCUIT
FAULT CIRCUIT
INTERRUPTERS
INTERRUPTERS
JUNCTION JUNCTION
BOX
BOX
JUNCTION
BOX
Flexible
Overflow Piping
(Factory installed)
N
L
N
TURBINE WITH GEYSAIR
(FOR MIAPLUS®, MIAMULTI®)
16 L
N
L N
L
GEYSAIR
MODULE
AROMACLOUD® TURBINE WITHOUTINMIX
®
MIAMULTI®)
(AROMATHERAPY) (FOR MIAPLUS , (CHROMATHERAPY)
1 800 463.2187
N
L
AIRSTREME
(WARMTOUCHSHELL®)
Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST)
Printed in Canada. Copyright © March 2017 BainUltra Inc. All rights reserved. 45200655
OPALIA COLLECTION
TM
INSTALLATION INSTRUCTIONS
1
OPALIA - inst allat io n
PARTS
& TOOLS
REQUIRED
REMOTE
MOUNTING
OF TURBINE WITHOUT ACCESS UNDER BATH
PLUMBING - ISLAND TUB DRAIN INSTALLATION
HELPFUL TIP:
• Carefully place the tub
on its side, on a blanket
or a corrugated cardboard.
Anchor
M
WARNING
• R
efer to supplied instructions
for Island Tub Drain installation.
Measure &
Align (2x)
Island
Tub Drain
OPTIONAL PARTS - PLUMBING(
DESCRIPTION
QTY
FTee Brass drain shoe1
G 6 in. brass tailpiece1
H Nylon conic shaped seal for drain1
I
Brass nut1
J
Nylon flat seal with flange1
K
Nylon flat seal with flange1
L
1-1/2” male threaded adaptor1
F
Flexible
Overflow Piping
(Factory installed)
L
K
J
I
H
www.bainultra.com
Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.
G
17 OPALIA COLLECTION
TM
INSTALLATION INSTRUCTIONS
OPALIA - inst allat io n
REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH
2
TURBINE & GEYSAIR INSTALLATION (FOR THERMOMASSEUR®)
PASSAGE FOR THE ELECTRICAL WIRING OF OPTIONAL THERAPIES
WARNING
IF THE AIR PIPING CONNECTIONS AND POWER SUPPLY OF THERAPEUTIC OPTIONS HAVE TO BE AT FLOOR LEVEL, YOU
MUST MAKE AN OPENING ON ONE SIDE OF THE BATH, AS CLOSE AS POSSIBLE TO TURBINE AND CONTROLS.
• Do not drill through the interior shell.
• The size of the opening must be large enough to allow wires and pipes to go through.
TOOLS REQUIRED
Drill
1/4 in. drill bit
Jig saw with fine cut blade
OPALIA 6938
•Air pipe*
•Geysair
• E
lectric cables
(Optional therapies)
(*) : Location of air pipe can differ from drawing.
18 1 800 463.2187
Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST)
Printed in Canada. Copyright © March 2017 BainUltra Inc. All rights reserved. 45200655
OPALIA COLLECTION
TM
INSTALLATION INSTRUCTIONS
2
OPALIA - inst allat io n
REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH
TURBINE & GEYSAIR INSTALLATION (FOR THERMOMASSEUR®)
Geysair Hose and
Back Flow Preventer
1-1/2 I.D. PVC AIR INTAKE PIPE
(«TIGERFLEX®» FLEXIBLE PVC)
1-1/2 I.D. ABS, PVC PIPE
(RIGID or «TIGERFLEX»)
& Fittings (not included)
Hot Water Supply
TURBINE REMOTE
MOUNTING
SEE STEP 7 page 13
WARNING
•Access to Geysair® backflow preventer is necessary for cleaning of the filter.
•Baths from Opalia™ collection cannot be drilled for faucet installation. Faucets must be freestanding
or wall-mounted models.
•Geysair component cannot be remote mounted. It must stay at original position, attached to bath.
Must never be unplugged.
3
ELECTRICAL WIRING OF OPTIONAL COMPONENTS
REMOTE MOUNTING
of CONTROL MODULES
SEE STEP 8 page 14
www.bainultra.com
Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.
19 OPALIA COLLECTION
TM
INSTALLATION INSTRUCTIONS
OPALIA - inst allat io n
REMOTE
PARTS & MOUNTING
TOOLS REQUIRED
OF TURBINE WITHOUT ACCESS UNDER BATH
4
BATH INSTALLATION – OPALIA WITH ISLAND TUB DRAIN
HELPFUL TIPS:
• Carefully place the tub
on its side, on a blanket
or a corrugated cardboard.
•To easily manipulate the bathtub
in a safe way during installation,
we recommend using moving straps.
Anchor M
WARNING
Measure
& Align (2x)
• Be sure the floor is leveled. Use shims as needed.
•Do not remove the protective plastic film on the tub and place a drop-cloth in the tub during installation to protect the acrylic.
• Apply a bead of silicone around the perimeter of the bath once on the floor.
• Connect the drain.
• Install bath on anchors « M» previously screwed to the floor. Remove exceeding silicone.
• Connect the drain.
• Fix bath to floor by using washers «O» and nuts «N».
•Install the bath on anchors « M » previously
screwed to floor. Remove exceeding silicone.
• Place cover seals «Q» over openings.
N
O
Q
M
20 1 800 463.2187
Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST)
Printed in Canada. Copyright © March 2017 BainUltra Inc. All rights reserved. 45200655
OPALIA COLLECTION
TM
INSTALLATION INSTRUCTIONS
4
OPALIA - inst allat io n
REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH
BATH INSTALLATION
DRAIN CONNECTION WITH ISLAND TUB DRAIN® (ITD) - INFORMATION
WARNING
•Refer to supplied instructions
for ISLAND TUB DRAIN® installation.
ISLAND TUB DRAIN®
Floor surface
WARNING
Use the 6 in. (15 cm) tail piece
supplied with Island Tub Drain®
www.bainultra.com
Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.
21 OPALIA COLLECTION
TM
INSTALLATION INSTRUCTIONS
OPALIA - inst allat io n
PARTS
& TOOLS
REQUIRED
REMOTE
MOUNTING
OF TURBINE WITHOUT ACCESS UNDER BATH
FOR THE NEXT STEPS, SEE SECTION : REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER THE BATH
5 ELECTRONIC CONTROL INSTALLATION – MIAPLUS® & MIAMULTI® (OPTION)..................................................11
5 ELECTRONIC CONTROL INSTALLATION – DOT (THERAPIES)..........................................................................11
6 REMOTE MOUNTING OF TURBINE...............................................................................................................12
7 REMOTE MOUNTING OF TURBINE – AIR PIPE (THERMOMASSEUR®)...............................................................13
7 REMOTE MOUNTING OF TURBINE – ELECTRICAL CONNECTIONS (THERMOMASSEUR®))................................13
8 REMOTE MOUNTING OF TURBINE – ELECTRICAL CONNECTIONS OF OPTIONAL THERAPIES..........................14
8 REMOTE MOUNTING OF OPTIONAL THERAPIES – ELECTRICAL CONNECTIONS..............................................15
22 ELECTRICAL DIAGRAM - THERMOMASSEUR & THERAPIES............................................................................16
1 800 463.2187
Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST)
Printed in Canada. Copyright © March 2017 BainUltra Inc. All rights reserved. 45200655


OPALIA
OPALIA
CUTTING TEMPLATES / GABARITS DE PERÇAGE

1.625"
[4.1 cm]
Cut-out for MiaMulti® infrared
Trou pour infrarouge MiaMulti®
1.625"
[4.1 cm]
0.875"
[2.2 cm]
1.375"
[3.5 cm]
1.625"±0.04"
1.625"
[4.1 cm±0.1 cm]
[4.1 cm]
1.125"
0.875"[2.9 cm]
R0.125"
[2.2 cm]
[R0.3 cm]
1.625"±0.04"
[4.1 cm±0.1 cm]
1.125"
[2.9 cm]
1.375"
[3.5 cm]


R0.125"
[R0.3 cm]
1.375"
[3.5 cm]

1.063"
[2.7 cm]
1.063"
[2.7 cm]
[5.5 cm]
MIAPLUS & MIAMULTI
MIAPLUS & MIAMULTI
2.165"
5.591" [14.2 cm]
Control cut-out
Trou du contrôle
Control outline
Contour du contrôle
Control cut-out
Trou du contrôle
Control5.591"
outline[14.2 cm]
Contour du contrôle
2.165"
[5.5 cm]
R0.250"
[R0.6 cm]
R0.250" Control cut-out
[R0.6 cm] Trou du contrôle
Control outline
Contour du contrôle
R0.250"
[R0.6 cm]
11.313"
[28.7 cm]
11.313"
[28.7 cm]
PRISE D'AIR - OUVERTURE
AIR INTAKE - OPENING
AIR INTAKE - OPENING
PRISE D'AIR 11.063"
- OUVERTURE
[28.1 cm]PRISE D'AIR - OUVERTURE
11.063"
[28.1 cm]
1 800 463.2187
2.165"
[5.5 cm]
1.625"±0.04"
[4.1 cm±0.1 cm]
AIR INTAKE - OPENING
1.063"
[2.7 cm]
5.125"±0.04"
[13.0 cm±0.1 cm]
MIAPLUS & MIAMULTI
R0.125"
[R0.3 cm]
11.313"
[28.7 cm]
24
5.125"±0.04"
[13.0 cm±0.1 cm]
5.591" [14.2 cm]


0.875"
[2.2 cm]
Cut-out for MiaMulti® infrared
Trou pour infrarouge MiaMulti®
1.125"
[2.9 cm]
5.125"±0.04"
[13.0 cm±0.1 cm]
Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST)
Du lundi au jeudi, De 8 h à 20 h (HE) . Vendredi de 8 h à 17 h (HE)
Printed in Canada. Copyright © March 2017 BainUltra Inc. All rights reserved. 45200655
Imprimé au Canada. Copyright © mars 2017 BainUltra inc. Tous droits réservés.
11.063"
[28.1 cm]
0.813"
[2.1 cm]
0.813"
[2.1 cm]
R0.125"
[R0.3 cm]
R0.125"
[R0.3 cm]
0.813"
[2.1 cm]
R0.125"
[R0.3 cm]
www.bainultra.com
Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.
Certains produits, spécifications et services mentionnés dans le présent manuel sont décrits dans des demandes de brevets en instance ou protégés par des brevets.
CU TTI NG TEM PL AT ES / GA B AR ITS D E PERÇAGE
Cut-out for MiaMulti® infrared
Trou pour infrarouge MiaMulti®
CUTTING TEMPLATES / GABARITS DE PERÇAGE
25
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising