CONSTANT PRESSURE CONTROLLERS

CONSTANT PRESSURE CONTROLLERS
CONSTANT PRESSURE
CONTROLLERS
SUBDRIVE AND MONODRIVE
Franklin Electric’s SubDrive and MonoDrive constant pressure
controllers provide constant pressure by continually adjusting
the speed of the pump to match water demand. Instead
of draining and filling a large tank, a SubDrive system
pumps more or less water as you need it. Finally,
you’ll be able to run the dishwasher, do laundry,
and water the lawn - all at the same time!
franklinwater.com
DESCRIPTION
BENEFITS
ƒƒ Constant water pressure with a wide range of settings
ƒƒ Works with small pressure tanks or existing larger tanks
ƒƒ Single-phase input power
ƒƒ Advanced filtering to remove radio frequency interference
ƒƒ FE Connect smartphone app for advanced settings and monitoring*
ƒƒ UL and cUL listed
ƒƒ User-configurable motor frequency range*
ƒƒ Easy installation
ƒƒ Built-in diagnostics and protection (surge protection, short circuit,
underload, overheat controller, undervoltage, broken-pipe detection*,
locked pump, user-configurable underload off-time*, open circuit,
optional moisture/wet-floor sensor protection)
ƒƒ Soft-start feature prevents water hammer and increases motor life
ƒƒ Supports surface pumping applications*
ƒƒ Pressure transducer input with system pressure display*
* Functionality for Connect models only
APPLICATIONS
ƒƒ Residential homes
ƒƒ Farms
ƒƒ Car washes
ƒƒ Restaurants
ƒƒ Schools
ƒƒ Landscape irrigation systems
SINGLE-PHASE SYSTEMS
MonoDrive and MonoDriveXT are designed to convert a conventional ½ hp to 2 hp pump system to a variable speed constant pressure system by simply replacing
the 3-wire control box and pressure switch.
ƒƒ Easily replaceable fan kit
ƒƒ Single-phase input, 3-wire motor control
ƒƒ Easy, plug-and-play installation
ƒƒ UL and cUL listed
ƒƒ ½–2 hp (MonoDrive) and ½–3 hp (SubDrive50) performance
ƒƒ NEMA 3R and NEMA 4 enclosure options (indoor/outdoor)
THREE-PHASE SYSTEMS
SubDrive15, SubDrive20, SubDrive30, SubDrive50, SubDrive75, SubDrive100, SubDrive150, and SubDrive300 are designed for three-phase motors to provide
constant pressure with three-phase performance using single-phase input power.
ƒƒ Single-phase input, three-phase motor control
ƒƒ Easy, plug-and-play installation
ƒƒ UL and cUL listed
ƒƒ 1–5 hp performance
ƒƒ Easily replaceable fan kit
ƒƒ NEMA 3R and NEMA 4 enclosures (indoor/outdoor)
ƒƒ Smooth running
ƒƒ High starting torque
ƒƒ Surface pumps (Connect models only)
SUBDRIVE2W
SubDrive2W is designed to convert a conventional ½ hp, ¾ hp, and 1 hp pump system to a variable speed constant pressure system by simply replacing the
pressure switch. Maximum pump output using the SD2W is similar to the performance achieved using a conventional pressure switch. Therefore, the pump
selection criteria are the same as if a pressure switch were used. (Refer to the pump manufacturer’s literature for details of the pump selection procedure.)
ƒƒ Single-phase input, 2-wire motor control
ƒƒ ½, ¾, or 1 hp performance
ƒƒ NEMA 3R rated enclosure
ƒƒ Easy, plug-and-play retrofit installation
2
ƒƒ Easily replaceable fan and air filter kit
ƒƒ UL and cUL listed
FE CONNECT MOBILE APP
SUBDRIVE/MONODRIVE CONNECT MODELS
Wi-Fi connectivity is included in the drive to enable a connection to be made between the drive and a single mobile
device (smartphone and tablet). This connection can be used to monitor drive characteristics, adjust advanced settings,
and view and email fault history and configuration changes.
CONNECTING TO WI-FI
ƒƒ Cycle power – Wi-Fi radio can only be connected within the first 15 minutes of power up.
ƒƒ The FE Connect light will illuminate solid to indicate that a connection is available.
ƒƒ Open the Wi-Fi connection settings on the mobile device you wish to use to connect to the drive.
ƒƒ Select the “FECNCT_XXXXX” hotspot (“XXXXX” is the end portion of the serial number of the drive being connected to).
ƒƒ The FE Connect light on the drive will flash to indicate that a connection is being made. Only one (1) mobile device can
be connected to a drive at any given time.
ƒƒ After making a successful connection, launch the FE Connect App on your mobile device. The app can be downloaded
from the Apple App Store or Google Play depending on the device being used.
ƒƒ This connection will stay active until the connection is broken or device is out of range.
ƒƒ Connection can be re-established for up to one hour following a disconnection.
MONITORING
This page allows for real-time monitoring of the system, including:
ƒƒ System Status
ƒƒ Output Current
ƒƒ Motor Speed
ƒƒ System Pressure (requires pressure transducer)
ƒƒ System Info (Drive Model, Hardware/Software Ver.)
ƒƒ Input Voltage
SETUP
The Setup page allows for the setup of additional features of the drive, including:
ƒƒ Underload Off Time
ƒƒ Minimum/Maximum Frequency
ƒƒ Underload Sensitivity*
ƒƒ System Pressure Setpoint*
ƒƒ Aggressive Bump
ƒƒ Tank Size Mode
ƒƒ Duplex Alternator Function
ƒƒ Motor Size*
ƒƒ Units (hp or kW)
ƒƒ Auxiliary Input
ƒƒ Broken Pipe Detection
ƒƒ Motor Overload Current***
ƒƒ Moisture/Wet-Floor Sensor
ƒƒ Pump Size*
ƒƒ Prime Delay***
ƒƒ Cut-in Pressure Setpoint/Drawdown**
ƒƒ Bump Mode
ƒƒ Drive Output*
ƒƒ Steady Flow*
* In order to change and use app settings for the Drive Output, Motor Size, Pump Size, Underload Sensitivity, and Steady Flow, the FE Connect DIP switch (SW1, Position 1) on the drive must be on (up).
Otherwise, the drive will default to the settings made via the DIP switches and Underload Sensitivity rotary knob on the drive itself.
** Requires pressure transducer
*** Surface pumping applications
LOGS
This page allows for viewing and emailing fault history and configuration changes with real date and time stamps.
ƒƒ View drive power up time
ƒƒ View motor run time
ƒƒ View/email Fault History events
ƒƒ View/email Configuration Changes
3
ENCLOSURE OPTIONS
ƒƒ NEMA 3R: The NEMA 3R enclosure is rated for indoor and outdoor use. It provides a degree of protection against falling rain and sleet.
ƒƒ NEMA 4: The NEMA 4 weatherproof enclosure is designed for both indoor and outdoor use and offers robust protection against harsh environmental conditions.
NEMA 3R
NEMA 4
CONSTANT PRESSURE SYSTEM
Pressure Transducer must
be installed in the upright
and vertical position.
B
C
Pressure
Transducer
Leads
D Pressure Sensor/Transducer
Pressure
Relief Valve
PUMP
A
Power Supply
from Circuit Breaker
4
MOTOR
Power to Motor
Supplied with Sensor:
NEMA 1, NEMA 4,
SD2W, and SD300
Supplied with Transducer:
SubDrive/MonoDrive Connect Models
SPECIFICATIONS
Model No.
Indoor/Outdoor
Voltage
Phase In
Frequency
MonoDrive (NEMA 3R)
Model 5870205003C
MonoDrive (NEMA 4)
Model 5870203114
208/230 VAC
Single-phase
60/50 Hz
5.7 Amps (RMS) 1/2 hp, 0.37 kW system
8.7 Amps (RMS) 3/4 hp, 0.55 kW system
11 Amps (RMS) 1 hp, 0.75 kW system
~ 0.95
4 Watts
190-260 VAC
Single-phase
60/50 Hz
5.7 Amps (RMS) 1/2 hp, 0.37 kW system
Current (max)
8.7 Amps (RMS) 3/4 hp, 0.55 kW system
Input from
11 Amps (RMS) 1 hp, 0.75 kW system
Power Source
Power Factor
1.0 (constant)
Power (idle)
35 Watts
1150 Watts (1/2 hp, 0.37 kW) system
Power (max)
2500 Watts
1750 Watts (3/4 hp, 0.55 kW) system
2150 Watts (1 hp, 0.75 kW) system
Wire Gauge Size(s)
Consult Federal, State, and Local codes for branch circuit installations Consult Federal, State, and Local codes for branch circuit installations
Voltage
Adjusts with Frequency
Adjusts with Frequency
Phase Out
Single-phase (3-wire)
Single-phase (3-wire)
Frequency Range
30-63 Hz
30-60 Hz
Output to Motor
Main Phase: 6 Amps (RMS) 1/2 hp, 0.37 kW system
Main Phase: 6 Amps (RMS) 1/2 hp, 0.37 kW system
Main Phase: 8 Amps (RMS) 3/4 hp, 0.55 kW system
Current (max)
Main Phase: 8 Amps (RMS) 3/4 hp, 0.55 kW system
Main Phase: 10.4 Amps (RMS) 1 hp, 0.75 kW system
Main Phase: 10.4 Amps (RMS) 1 hp, 0.75 kW system
Wire Gauge Size(s)
#6 - #14 * ga.
#6 - #18 * ga.
Factory Preset
50 psi (3.4 bar)
50 psi (3.4 bar)
Pressure Setting
Adjustment Range
25-80 psi (1.7 - 5.5 bar)
25-80 psi (1.7 - 5.5 bar)
Operating
Temperature (at 230 VAC input)
-13 °F to 122 °F (-25 °C to 50 °C)
-13 °F to 125 °F (-25 °C to 50 °C)
Conditions (A)
Relative Humidity
20-95%, non-condensing
0-100%, condensing
Controller Size (B)
Outer Dimensions
9-3/4" x 16-3/4" x 5-1/4" (25 x 42.5 x 13 cm)
17-1/2" x 16-3/8" x 11-3/8" (44.45 x 41.59 x 28.89 cm)
(approximate)
Weight
20 lbs (9 kg)
24.14 lbs (10.95 kg)
0.5 hp (0.37 kW) pump with 214505-Series motor
0.5 hp (0.37 kW) pump with 214505-Series motor
Pump (60 Hz)
0.75 hp (0.55 kW) pump with 214507-Series motor
0.75 hp (0.55 kW) pump with 214507-Series motor
1.0 hp (0.75 kW) pump with 214508-Series motor
1.0 hp (0.75 kW) pump with 214508-Series motor
For Use With (C)
214505-Series (0.5 hp, 0.37 kW) single-phase, 3-wire
214505-Series (0.5 hp, 0.37 kW) single-phase, 3-wire
FE Motor
214507-Series (0.75 hp, 0.55 kW) single-phase, 3-wire
214507-Series (0.75 hp, 0.55 kW) single-phase, 3-wire (default)
214508-Series (1.0 hp, 0.75 kW) single-phase, 3-wire
214508-Series (1.0 hp, 0.75 kW) single-phase, 3-wire
NOTES: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
(A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
(B) Refer to detailed Mounting Dimensions.
(C) If a pump other than the default rating is used, refer to Drive Configuration.
* Refer to detailed Circuit Breaker and Wire Sizing charts.
5
SPECIFICATIONS
Model No.
Indoor/Outdoor
Voltage
Phase In
Frequency
MonoDriveXT (NEMA 3R)
Model 5870205203C
190-260 VAC
Single-phase
60/50 Hz
13 Amps (RMS) 1.5 hp, 1.1 kW system
Current (max)
Input from
16 Amps (RMS) 2 hp, 1.5 kW system
Power Source
Power Factor
1.0 (constant)
Power (idle)
65 Watts
2500 Watts (1.5 hp, 1.1 kW) system
Power (max)
4200 Watts
3100 Watts (2 hp, 1.5 kW) system
Wire Gauge Size(s)
Consult Federal, State, and Local codes for branch circuit installations Consult Federal, State, and Local codes for branch circuit installations
Voltage
Adjusts with Frequency
Adjusts with Frequency
Phase Out
Single-phase (3-wire)
Single-phase (3-wire)
Frequency Range
30-63 Hz
30-60 Hz
Output to Motor
Main Phase: 11.5 Amps (RMS) 1.5 hp, 1.1 kW system
Main Phase: 11.5 Amps (RMS) 1.5 hp, 1.1 kW system
Current (max)
Main Phase: 13.2 Amps (RMS) 2 hp, 1.5 kW system
Main Phase: 13.2 Amps (RMS) 2 hp, 1.5 kW system
Wire Gauge Size(s)
#6 - #14 * ga.
#6 - #18 * ga.
Factory Preset
50 psi (3.4 bar)
50 psi (3.4 bar)
Pressure Setting
Adjustment Range
25-80 psi (1.7 and 5.5 bar)
25-80 psi (1.7 - 5.5 bar)
Operating
Temperature (at 230 VAC input)
-13 °F to 122 °F (-25 °C to 50 °C)
-13 °F to 125 °F (-25 °C to 50 °C)
Conditions (A)
Relative Humidity
20-95%, non-condensing
0-100%, condensing
Controller Size (B)
Outer Dimensions
9-3/4" x 19-3/4" x 5-1/4" (25 x 50 x 13 cm)
17-1/2" x 16-3/8" x 11-3/8" (44.45 x 41.59 x 28.89 cm)
(approximate)
Weight
26 lbs (11.8 kg)
28.32 lbs (12.84 kg)
1.0 hp (0.75 kW) pump with 214508-Series motor
1.0 hp (0.75 kW) pump with 214508-Series motor
Pump (60 Hz)
1.5 hp (1.1 kW) pump with 224300-Series motor
1.5 hp (1.1 kW) pump with 224300-Series motor
2.0 hp (1.5 kW) pump with 224301-Series motor
2.0 hp (1.5 kW) pump with 224301-Series motor
For Use With (C)
214508-Series (1.0 hp, 0.75 kW) single-phase, 3-wire
214508-Series (1.0 hp, 0.75 kW) single-phase, 3-wire
FE Motor
224300-Series (1.5 hp, 1.1 kW) single-phase, 3-wire
224300-Series (1.5 hp, 1.1 kW) single-phase, 3-wire (default)
224301-Series (2.0 hp, 1.5 kW) single-phase, 3-wire
224301-Series (2.0 hp, 1.5 kW) single-phase, 3-wire
NOTES: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
(A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
(B) Refer to detailed Mounting Dimensions.
(C) If a pump other than the default rating is used, refer to Drive Configuration.
* Refer to detailed Circuit Breaker and Wire Sizing charts.
6
208/230 VAC
Single-phase
60/50 Hz
13 Amps (RMS) 1.5 hp, 1.1 kW system
16 Amps (RMS) 2 hp, 1.5 kW system
~ 0.95
5 Watts
MonoDriveXT (NEMA 4)
Model 5870204114
SPECIFICATIONS
Model No.
Input from
Power Source
Output to Motor
Pressure Setting
Operating
Conditions (A)
Controller Size (B)
(approximate)
For Use With (C)
Indoor/Outdoor
SubDrive15 (NEMA 3R) (D)
Model 5870205103C
SubDrive20 (NEMA 3R) (D)
Model 5870205303C
Voltage
Phase In
Frequency
Current (max)
Power Factor
Power (idle)
Power (max)
Wire Gauge Size(s)
Voltage
Phase Out
208/230 VAC
208/230 VAC
Single-phase
Single-phase
60/50 Hz
60/50 Hz
12 Amps
19 Amps
~ 0.95
~ 0.95
4 Watts
5 Watts
2500 Watts
4200 Watts
Consult Federal, State, and Local codes for branch circuit installations Consult Federal, State, and Local codes for branch circuit installations
Adjusts with Frequency
Adjusts with Frequency
Single-phase (3-wire) OR Three-phase
Single-phase (3-wire) OR Three-phase
30-77 Hz (3/4 hp, 0.55 kW) pump
30-78 Hz (1hp, 0.75 kW) pump
30-72 Hz (1 hp, 0.75 kW) pump
30-72 Hz (1.5 hp, 1.1 kW) pump
Frequency Range
30-60 Hz (1.5 hp, 1.1 kW) pump
30-60 Hz (2 hp, 1.5 kW) pump
30-63 Hz (Single-phase Motors)
30-63 Hz (Single-phase Motors)
Current (max)
5.9 A / phase
8.1 A / phase
Wire Gauge Size(s)
#6 - #14 * ga.
#6 - #14 * ga.
Factory Preset
50 psi (3.4 bar)
50 psi (3.4 bar)
Adjustment Range
25-80 psi (1.7 - 5.5 bar)
25-80 psi (1.7 - 5.5 bar)
Temperature (at 230 VAC input)
-13 °F to 122 °F (-25 °C to 50 °C)
-13 °F to 122 °F (-25 °C to 50 °C)
Relative Humidity (NEMA 3R)
20-95%, non-condensing
20-95%, non-condensing
Outer Dimensions
9-3/4" x 19-3/4" x 5-1/4" (25 x 50 x 13 cm)
9-3/4" x 19-3/4" x 5-1/4" (25 x 50 x 13 cm)
Weight
26 lbs (11.8 kg)
26 lbs (11.8 kg)
1.0 hp (0.75 kW) pump with 214508-Series motor
1.5 hp (1.1 kW) pump with 224300-Series motor
0.5 hp (0.37 kW) pump with 214505-Series motor
0.75 hp (0.55 kW) pump with 214507-Series motor
2.0 hp (1.5 kW) pump with 224301-Series motor
0.75 hp (0.55 kW), 1.0 hp (0.75 kW), or 1.5 hp (1.1 kW) pump with
Pump (60 Hz)
1.0 hp (0.75 kW) pump with 214508-Series motor
234514-Series motor
0.75 hp (0.55 kW), 1.0 hp (0.75 kW), or 1.5 hp (1.1 kW) pump with
234514-Series motor
1.0 hp (0.75 kW), 1.5 hp (1.1 kW), or 2.0 hp (1.5 kW) pump with
234315-Series motor
214508-Series (1.0 hp, 0.75 kW) single-phase, 3-wire
214505-Series (0.5 hp, 0.37 kW) single-phase, 3-wire
224300-Series (1.5 hp, 1.1 kW) single-phase, 3-wire
214507-Series (0.75 hp, 0.55 kW) single-phase, 3-wire
FE Motor
224301-Series (2.0 hp, 1.5 kW) single-phase, 3-wire
214508-Series (1.0 hp, 0.75 kW) single-phase, 3-wire
234514-Series (1.5 hp, 1.1 kW) three-phase
234514-Series (1.5 hp, 1.1 kW) three-phase
234315-Series (2.0 hp, 1.5 kW) three-phase
Surface Pumps
2.0-5.9 Amps, three-phase, 230 VAC three-phase
2.0-8.1 Amps, three-phase, 230 VAC three-phase
NOTES: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
(A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
(B) Refer to detailed Mounting Dimensions.
(C) If a pump other than the default rating is used, refer to Drive Configuration.
(D) When operating a SubDrive as a MonoDrive, the MonoDrive NEMA 3R pump and motor specifications on Page 5 apply.
* Refer to detailed Circuit Breaker and Wire Sizing charts.
7
SPECIFICATIONS
Model No.
Input from
Power Source
Output to Motor
Pressure Setting
Operating
Conditions (A)
Controller Size (B)
(approximate)
For Use With (C)
Indoor/Outdoor
SubDrive30 (NEMA 3R) (D)
Model 5870205403C
Voltage
Phase In
Frequency
Current (max)
Power Factor
Power (idle)
Power (max)
Wire Gauge Size(s)
Voltage
Phase Out
208/230 VAC
190-260 VAC
Single-phase
Single-phase
60/50 Hz
60/50 Hz
23 Amps
11 Amps (RMS)
~ 0.95
1.0 (constant)
5 Watts
35 Watts
4200 Watts
2400 Watts
Consult Federal, State, and Local codes for branch circuit installations Consult Federal, State, and Local codes for branch circuit installations
Adjusts with Frequency
Adjusts with Frequency
Single-phase (3-wire) OR Three-phase
Three-Phase (3-wire)
30-78 Hz (1.5 hp, 1.1 kW) pump
30-80 Hz (3/4 hp, 0.55 kW) pump
30-70 Hz (2 hp, 1.5 kW) pump
30-70 Hz (1 hp, 0.75 kW) pump
Frequency Range
30-60 Hz (3 hp, 2.2 kW) pump
30-60 Hz (1.5 hp, 1.1 kW) pump
30-63 Hz (Single-Phase Motors)
Current (max)
10.9 A / phase
5.9 Amps (RMS, each phase)
Wire Gauge Size(s)
#6 - #14 * ga.
#6 - #18 * ga.
Factory Preset
50 psi (3.4 bar)
50 psi (3.4 bar)
Adjustment Range
25-80 psi (1.7 - 5.5 bar)
25-80 psi (1.7 and 5.5 bar)
Temperature (at 230 VAC input)
-13 °F to 122 °F (-25 °C to 50 °C)
-13 °F to 125 °F (-25 °C to 50 °C)
Relative Humidity
20-95%, non-condensing
0-100%, condensing
Outer Dimensions
9-3/4" x 19-3/4" x 5-1/4" (25 x 50 x 13 cm)
17-1/2" x 16-3/8" x 11-3/8" (44.45 x 41.59 x 28.89 cm)
Weight
26 lbs (11.8 kg)
24.14 lbs (10.95 kg)
1.0 hp (0.75 kW) pump with 214508-Series motor
1.5 hp (1.1 kW) pump with 224300-Series motor
2.0 hp (1.5 kW) pump with 224301-Series motor
0.75 hp (0.55 kW), 1.0 hp (0.75 kW), or 1.5 hp (1.1 kW) pump with
3/4 hp (0.55 kW) [default]
234514-Series motor
1 hp (0.75 kW)
Pump (60 Hz)
1.0 hp (0.75 kW), 1.5 hp (1.1 kW), or 2.0 hp (1.5 kW) pump with
1.5 hp (1.1 kW)
234315-Series motor
1.5 hp (1.1 kW), 2.0 hp (1.5 kW), or 3.0 hp (2.2 kW) pump with
234316-Series motor
214508-Series (1.0 hp, 0.75 kW) single-phase, 3-wire
224300-Series (1.5 hp, 1.1 kW) single-phase, 3-wire
224301-Series (2.0 hp, 1.5 kW) single-phase, 3-wire
FE Motor
234514-Series (1.5 hp, 1.1 kW)
234514-Series (1.5 hp, 1.1 kW) three-phase
234315-Series (2.0 hp, 1.5 kW) three-phase
234316-Series (3.0 hp, 2.2 kW) three-phase
Surface Pumps
2.0-10.9 Amps, three-phase, 230 VAC three-phase
-
NOTES: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
(A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
(B) Refer to detailed Mounting Dimensions.
(C) If a pump other than the default rating is used, refer to Drive Configuration.
(D) When operating a SubDrive as a MonoDrive, the MonoDrive NEMA 3R pump and motor specifications on Page 5 apply.
* Refer to detailed Circuit Breaker and Wire Sizing charts.
8
SubDrive75 (NEMA 4)
Model 5870203384
SPECIFICATIONS
Model No.
Indoor/Outdoor
SubDrive100 (NEMA 4)
Model 5870204104
SubDrive150 (NEMA 4)
Model 5870204154
Voltage
Phase In
Frequency
Current (max)
Power Factor
Power (idle)
Power (max)
Wire Gauge Size(s)
Voltage
Phase Out
190-260 VAC
190-260 VAC
Single-phase
Single-phase
60/50 Hz
60/50 Hz
Input from
19 Amps (RMS)
23 Amps (RMS)
Power Source
1.0 (constant)
1.0 (constant)
65 Watts
65 Watts
3800 Watts
4600 Watts
Consult Federal, State, and Local codes for branch circuit installations Consult Federal, State, and Local codes for branch circuit installations
Adjusts with Frequency
Adjusts with Frequency
Three-phase (3-wire)
Three-phase (3-wire)
30-80 Hz (1 hp, 0.75 kW) pump
30-80 Hz (1.5 hp, 1.1 kW) pump
Output to Motor
Frequency Range
30-70 Hz (1.5 hp, 1.1 kW) pump
30-70 Hz (2 hp, 1.5 kW) pump
30-60 Hz (3 hp, 2.2 kW) pump
30-60 Hz (2 hp, 1.5 kW) pump
Current (max)
8.1 Amps (RMS, each phase)
10.9 Amps (RMS, each phase)
Wire Gauge Size(s)
#6 - #18 * ga.
#6 - #18 * ga.
Factory Preset
50 psi (3.4 bar)
50 psi (3.4 bar)
Pressure Setting
Adjustment Range
25-80 psi (1.7 - 5.5 bar)
25-80 psi (1.7 - 5.5 bar)
Operating
Temperature (at 230 VAC input)
-13 °F to 125 °F (-25 °C to 50 °C)
-13 °F to 125 °F (-25 °C to 50 °C)
Conditions (A)
Relative Humidity
0-100%, condensing
0-100%, condensing
Controller Size (B)
Outer Dimensions
17-1/2" x 16-3/8" x 11-3/8" (44.45 x 41.59 x 28.89 cm)
17-1/2" x 16-3/8" x 11-3/8" (44.45 x 41.59 x 28.89 cm)
(approximate)
Weight
28.32 lbs (12.84 kg)
28.32 lbs (12.84 kg)
1 hp (0.75 kW) [default]
1.5 hp (1.1 kW) [default]
Pump (60 Hz)
1.5 hp (1.1 kW)
2 hp (1.5 kW)
For Use With (C)
2 hp (1.5 kW)
3 hp (2.2 kW)
FE Motor
234315-Series (2 hp, 1.5 kW)
234316-Series (3 hp, 2.2 kW)
NOTES: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
(A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
(B) Refer to detailed Mounting Dimensions.
(C) If a pump other than the default rating is used, refer to Drive Configuration.
* Refer to detailed Circuit Breaker and Wire Sizing charts.
9
SPECIFICATIONS
Model No.
Input from
Power Source
Output to Motor
Pressure Setting
Operating
Conditions (A)
Controller Size (B)
(approximate)
For Use With (C)
Indoor/Outdoor
SubDrive300 (NEMA 4)
Model 5870206300
Voltage
Phase In
Frequency
Current (max)
Power Factor
Power (idle)
Power (max)
Wire Gauge Size(s)
Voltage
Phase Out
220-260 VAC
208/230 +/- 10% VAC
Single-phase
Single-phase
60/50 Hz
60/50Hz
36 Amps (RMS)
36 A
1.0 (constant)
~ 0.95
65 Watts
7 Watts
7200 Watts
7200 Watts
Consult Federal, State, and Local codes for branch circuit installations Consult Federal, State, and Local codes for branch circuit installations.
Adjusts with Frequency
Variable based on frequency
Three-phase (3-wire)
Single-phase (3-wire) OR three-phase
30-78 Hz: 1/2-rated mismatched pump with three-phase motor
30-70 Hz: 2/3 or 3/4-rated mismatched pump with three-phase motor
30-80 Hz (3 hp, 2.2 kW) pump
Frequency Range
30-60 Hz: Matched pump with three-phase motor
30-70 Hz (5 hp, 3.7 kW) pump
30-63 Hz: Matched pump with single-phase motor
Current (max)
17.8 Amps (RMS, each phase)
17.8 (three-phase), 17.0 A (single-phase)
Wire Gauge Size(s)
#2 - #18 * ga.
#6 - #12 * ga.
Factory preset
50 psi (3.4 bar)
50 psi (3.4 bar)
Analog Transducer: 5-95 PSI (0.3 - 6.6 bar)
Adjustment Range
25-80 psi (1.7 - 5.5 bar)
Pressure Sensor: 25-80 psi (1.7 - 5.5 bar)
Temperature (at 230 VAC input)
-13 °F to 125 °F (-25 °C to 50 °C)
-13 °F to 122 °F (-25 °C to 50 °C)
Relative Humidity
0-100%, condensing
20-95%, non-condensing
Outer Dimensions
19-7/8" x 17-1/2" x 14-1/4" (50.48 x 44.45 x 36.20 cm)
26 1/8" x 15 3/8" x 11 1/2" (66 x 39 x 29 cm)
Weight
35.15 lbs (15.94 kg)
31 lbs (14.1 kg)
0.5 hp (0.37 kW) pump with 214505-Series motor
0.75 hp (0.55 kW) pump with 214507-Series motor
1.0 hp (0.75 kW) pump with 214508-Series motor
1.5 hp (1.1 kW) pump with 224300-Series motor
2.0 hp (1.5 kW) pump with 224301-Series motor
3.0 hp (2.2 kW) pump with 224302-Series motor
0.5 hp (0.37 kW), 0.75 hp (0.55 kW), or 1.0 hp (0.75 kW) pump with
3 hp (2.2 kW) [default]
234513-Series motor
Pump (60 Hz)
5 hp (3.7 kW)
0.75 hp (0.55 kW), 1.0 hp (0.75 kW), or 1.5 hp (1.1 kW) pump with
234514-Series motor
1.0 hp (0.75 kW), 1.5hp (1.1 kW), or 2.0 hp (1.5 kW) pump with
234315-Series motor
1.5 hp (1.1 kW), 2.0 hp (1.5 kW), or 3.0 hp (2.2 kW) pump with
234316-Series motor
3.0 hp (2.2 kW), or 5.0 hp (3.7 kW) pump with 234317-Series motor
214505-Series (0.5 hp, 0.37 kW) single-phase, 3-wire
214507-Series (0.75 hp, 0.55 kW) single-phase, 3-wire
214508-Series (1.0 hp, 0.75 kW) single-phase, 3-wire
224300-Series (1.5 hp, 1.1 kW) single-phase, 3-wire
224301-Series (2.0 hp, 1.5 kW) single-phase, 3-wire
FE Motor
234317-Series (5 hp, 3.7 kW)
224302-Series (3.0 hp, 2.2 kW) single-phase, 3-wire
234513-Series (1.0 hp, 0.75 kW) three-phase
234514-Series (1.5 hp, 1.1 kW) three-phase
234315-Series (2.0 hp, 1.5 kW) three-phase
234316-Series (3.0 hp, 2.2 kW) three-phase
234317-Series (5.0 hp, 3.7 kW) three-phase
Surface Pumps
2.0-17.8 Amps, three-phase, 230 VAC three-phase
NOTES: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
(A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
(B) Refer to detailed Mounting Dimensions.
(C) If a pump other than the default rating is used, refer to Drive Configuration.
* Refer to detailed Circuit Breaker and Wire Sizing charts.
10
SubDrive50 (NEMA 3R)
5870205503C
SPECIFICATIONS
Model No.
Input from
Power Source
Indoor/Outdoor
Voltage
Phase In
Frequency
Current (max)
Power Factor
Power (idle)
Power (max)
Wire Gauge Size(s)
Voltage
Phase Out
Frequency Range
Output to Motor
Current (max)
Pressure Setting
Operating
Conditions (A)
Controller Size (B)
(approximate)
For Use With (C)
Wire Gauge Size(s)
Factory preset
Adjustment Range
Temperature (at 230 VAC input)
Relative Humidity
Outer Dimensions
Weight
Pump (60 Hz)
SubDrive2W (NEMA 3R)
Model 5870203223
207-260 VAC
Single-phase
60/50 Hz
14 Amps (RMS) (For circuit breaker sizing)
0.7 (approximate)
20 Watts
1900 Watts
Consult Federal, State, and Local codes for branch circuit installations
Adjusts with Frequency
Single-phase (2-wire)
30-60 Hz
6 Amps (RMS) 1/2 hp, 0.37 kW system
8 Amps (RMS) 3/4 hp, 0.55 kW system
10.4 Amps (RMS) 1 hp, 0.75 kW system
#6 - #18 * ga.
50 psi (3.4 bar)
25-80 psi (1.7 - 5.5 bar)
-13 °F to 125 °F (-25 °C to 50 °C)
10-95%, non-condensing
12-1/4" x 16-1/2" x 9" (31.1 x 41.9 x 22.9 cm)
15.0 lbs (6.80 kg)
1/2 hp pump/motor with 244505-Series
3/4 hp pump/motor with 244507-Series [default]
1 hp pump/motor with 244508-Series
Not Available
FE Motor
NOTES: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
(A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
(B) Refer to detailed Mounting Dimensions.
(C) If a pump other than the default rating is used, refer to Drive Configuration.
* Refer to detailed Circuit Breaker and Wire Sizing charts.
11
ACCESSORIES
Accessories
Detail
Part No.
Helps prevent insects from entering and damaging the internal components of the drive
SD2W
Helps prevent insects from entering and damaging the internal components of the drive SD15, SD20, SD30, MD, MDXT non-“C” models
Analog Pressure Transducer
4-20mA analog pressure transducer used with “C” models (includes 10 ft cable)
All “C” models - 100 PSI
Analog Pressure Transducer Cable Kit
Outdoor rated cable to connect analog pressure transducer to “C” drive models
Duplex Alternator
Allows a water system to alternate between two parallel pumps controlled by
separate SubDrives
All “C” models - 10 ft
All “C” models - 25 ft
All “C” models - 50 ft
All “C” models - 100 ft
All “C” models - 150 ft
All “C” models - 200 ft
225835901
226550901
226905902
226905903
226905904
226910901
226910902
226910903
226910904
226910905
226910906
Duplex Alternator Cable Kit
Communication cable kit required to use the built-in Duplex Alternator function
in “C” drive models
Enhanced Display Board Replacement Kit
Enhanced Pressure Input Board
Replacement Kit
Filter (Input)
Filter (Output)
Filter (System)
Replacement board for drives that have a damaged display
Replacement board for “C” drives that have experienced a surge on the
Enhanced Pressure Input Board.
Filter used on the input side of drive to help eliminate interference
Filter used on the output side of the drive to help eliminate interference
Filter used as a system filter on input/output of the drive to help eliminate interference
Filter (Surge Capacitors)
Capacitor used on the service panel to help eliminate power interference
Heatsink Cover Kit
Lightning Arrestor
Low Voltage Kit
Moisture Sensor Kit
NEMA 1 Fan Replacement Kit
NEMA 1 Fan Replacement Kit
NEMA 1 Fan Replacement Kit
NEMA 1 Fan Replacement Kit
NEMA 3R Fan Replacement Kit
NEMA 3R Fan Replacement Kit
NEMA 3R Fan Replacement Kit
NEMA 3R Fan Replacement Kit
NEMA 3R Fan Replacement Kit
NEMA 4 External Cooling Fan Replacement Kit
NEMA 4 External Cooling Fan Replacement Kit
NEMA 4 External Cooling Fan Replacement Kit
NEMA 4 Internal Stirring Fan Replacement Kit
NEMA 4 Auxiliary Relay Board
NEMA 4 Option Card
Pressure Sensor (High: 75-150 psi, NSF 61 rated)
Pressure Sensor (Std.: 25-80 psi, NSF 61 rated)
Sensor Cable Kit (Indoor)
Sensor Cable Kit (Indoor)
Sensor Cable Kit (outdoor)
Assists in preventing insects from entering and blocking fan area
Single-phase (Input Power)
Used to make adjustments to the voltage of the SubDrive
External sensor device that shuts down the drive when water is detected.
Replacement fan (date code prior to 08L)
Replacement fan (date code 08L and after)
Replacement fan (with date code prior to 08K)
Replacement fan (with date code 08K and after)
Replacement fan (with date code prior to 08K)
Replacement fan
Replacement fan
Replacement fan (with date code 14L and after)
Replacement fan (with date code 14L and after)
Replacement External fan (with date code prior to 14L)
Replacement External fan (with date code prior to 14L)
Replacement External fan (include 2 fans)
Replacement Internal Stirring fan (with date code prior to 14L)
Offers Run-Indication Relay (for date codes 09J through 14K)
Offers Run-Indication Relay and Underload Extended Off-Time (date codes 09J–14K)
Adjusts pressure in the water system from 75-150 psi (2-leaded cable)
Adjusts pressure in the water system from 25-80 psi (2-leaded cable)
Kit includes pressure sensor (25-80 psi, NSF 61 rated), pressure shut-off switch (100 psi)
and 10 foot cable (4-leaded cable)
Replacement board for drives that have experienced a surge on the
pressure sensor input (with date codes 14L and after)
100 feet of 22 AWG cable (2-leaded cable)
100 feet of 22 AWG cable (4-leaded cable)
100 feet of 22 AWG cable (2-leaded cable)
Sensor Direct Burial Cable
Designed to run in an underground trench without conduit to surround it
(4-leaded cable)
Tank Drawdown Kit
Allows the use of water stored in the tank during low flow demands
Tank Drawdown Kit
Allows use of tank-stored water during low-flow demands (date codes prior to 14L)
Pressure Sensor/Pressure Shut-Off Switch Kit
Pressure Sensor Input Board Replacement
* N1 = NEMA 1 (Indoors), N3R = NEMA 3R (Indoor/Outdoor), N4 = NEMA 4 (Outdoor)
12
Used With
Air Screen Kit
Air Screen Kit
All Models
5850012000
All “C” models - 10 ft
All “C” models - 50 ft
All “C” models - 100 ft
All “C” models
226895901
226895902
226895903
226540912
All “C” models
226540902
All models
All models (excluding SD300)
SD300
All SubDrives/MonoDrives
(excl. SD2W and SD300)
All NEMA 4 models (excluding SD300)
Single-phase (Input Power)
SD300
All “C” models
SD75 and MD
SD75 and MD
SD100, SD150, and MDXT
SD100, SD150, and MDXT
SD75 and MD
SD2W
SD50
SD15 and MD
SD20, SD30, and MDXT
SD75 and MD
SD100, SD150, and MDXT
SD300
SD75, SD100, SD150, SD300, MD, MDXT
All NEMA 4 models (excluding SD300)
All NEMA 4 models (excluding SD300)
All models
All models
225198901
225300901
225650901
225805901
150814902
225950901
226770901
225635905
225635908
225635907
225635909
225635907
225635910
226545903
226545901
226545902
225635901
225635902
225635903
225635904
225755901
225880901
225970901
223995901
SD300
225495901
225199901
All models
226540901
All models excluding SD2W and SD300
SD300
All models
All models - 10 ft (3 m)
All models - 30 ft (9 m)
All models - 100 ft (30.5 m)
MDN3R, MDXTN3R, SD15, SD20,
SD30, SD2W, and SD300
SD75N4, SD100N4, SD150N4, MDN4,
and MDXTN4 (requires Auxiliary Relay
Board or NEMA 4 Option Card)
223995902
225495902
226941901
225800901
225800902
225800903
225770901
225770901
NOTES
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
13
NOTES
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
14
NOTES
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
15
franklinwater.com
M1459 03-17
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising