accessories - ClimateMaster

accessories - ClimateMaster
ACCESSORIES
UNIT AND LOOP ACCESSORIES
Accessories
Table of Contents
Accessory Description .......................................................................3
Loop Accessories................................................................................18
Accessory Compatability ..................................................................4
Extra Large Loop Accessories.....................................................20
Thermostats and Service Tools......................................................5
Installation Accessories ....................................................................21
AWC99B01 iGate® Connect, Two-Way
Communicating Thermostat ............................................................6
Geothermal Loop Pipe ...................................................................22
ATU3202 iGate Communicating Thermostat ....................7
Geothermal Fittings ...........................................................................23
®
ATP32U03 Thermostat ......................................................................9
ATP32U04 Thermostat ...................................................................11
ATA21U01 Thermostat ...................................................................13
AZ06CAR iGate ClimaZone Zoning Panel....................14
®
Socket Fusion Tools............................................................................25
Service Tools ..........................................................................................26
Service Parts Kit ..................................................................................26
Cabinet Samples..................................................................................26
TM
iGate® Smart Tank ..............................................................................15
Filters .........................................................................................................27
Revision History ..................................................................................28
Unit Accessories ..................................................................................16
2
ClimateMaster: Declare your personal energy independence.
ClimateMaster Geothermal Heating and Cooling
To further improve comfort and convenience,
ClimateMaster offers the following accessories
Water-to-Air
iGate® Smart Tank
ClimateMaster’s EarthPure® Polarized Media
Electronic Air Cleaner installs directly into the
2”/1” filter rack of your ClimateMaster heat
pump or air handler. The electronically enhanced
media combines elements of both electronic
and media air cleaners. It efficiently removes
particles down to 0.3 microns and REMOVES
ODORS.
Industry’s first Communicating water storage
tank, allows full-time year-round hot water by
communicating water temperature to the Trilogy®
Q-Mode® unit. The control on the Smart tank
controls the Titanium electric elements to minimize
use. The Seamless polybutene tank is designed for
a lifetime of highly efficient use and is impervious
to corrosion. The thick polyurethane foam offers
superior insulation compared to other storage
tanks. The tough, molded polyethylene exterior
resists dents, scratches, and salt air.
Tranquility® Secondary
Drain Pan
iGate® ClimaZone Zoning Panel
EarthPure® Electronic Air Cleaner
TM
This optional panel allows a single Trilogy
unit to be controlled by muliple thermostats,
conditioning the home in smaller zones
instead of one large single zone. One unit
accommodates up to 6 zones with a single
panel or up to 12 zones with two panels.
The ClimateMaster Secondary
Drain Pan was designed specifically
for Tranquility® Horizontal foot
prints. This drain pan matches
the unit perfectly for open ceiling
applications and to meet required
mechanical codes.
Remote Thermostat Sensor
Tranquility® Unit Vibration Isolation Pad
High density rubber pad for quiet
operation. The sound/vibration
isolation pad is ideal for second
floor, pier and beam construction
and attic installations.
Outdoor or Remote Temperature Sensor
SecureStart™ Compressor Soft Start Kit
Single phase compressors typically
have starting inrush currents that range
from five to seven times their normal
running current. The SecureStart™
module is designed to reduce inrush
current to the compressor by up to
75% and prevents lights dimming when
the compressor starts up.
Tranquility® Unit Stand
Compliment the ClimateMaster
Tranquility® product line with a
matching unit stand. This stand
is ideal for areas that must have
raised equipment to meet required
mechanical codes.
Water-to-Water
Auxiliary/Electric Heater
Anti-Scald Valve
Internally mounted in vertical cabinets.
Externally mounted on horizontal
cabinets. Sizes 15-20 kW AGM*A and
4-20 kW AGM*C include internal
circuit breaker. ETL listed. Circuit
fusing per UL/NEC. Wiring harness
connections included in residential units.
Anti-scald valve be used in DHW systems where
HWG setpoint is 150°F
Accessory Pump Slaving Module
Allows a single flow controller to be
controlled by 2 different units. Eliminates
additional field wiring and extra relays.
Flow Controller
Small Compact, proven design, easy to mount,
urethane foam insulated to prevent condensation,
includes factory supplied full flow service valves
for easy loop charging, Uses double o-ring adaptor
fittings for unit and loop connections. Gray
polystyrene cabinet with black pumps. Composite
3-way valves. 230VAC pump(s).
Residential Products Technical Guide
3
Accessories
Accessory Compatibility
Split
Water-toWater
Tranquility® Digital
Tranquility®
Packaged
Trilogy®
Accessories
QE
Tranquility®
Digital
TE
TZ
ATC thermostat/ ACD
service tool
X
X
ATP/ATA Thermostats
X
X
iGate® ClimaZoneTM
X
X
AWC iGate® Connect
thermostat
X
®
iGate Smart Tank
TS
TES, TEP
TAH, TAC
X
X
X
X
X
X
X
EarthPure® Polarized
Media Electronic Air
Cleaner
X
X
X
Secondary Drain Pan
X
X
X
Tranquility Unit Vibration
Isolation Pad
X
X
X
X
X
Tranquility® Unit Stand
X
X
X
X
X
Auxiliary Electric Heater
X
X
X
X
X
X
Remote/Outdoor
Temperature Sensor
X
X
X
X
X
X
X
X
®
ClimaDry
Potentiometer Kit
Anti Scald Valve
Secure Start Compressor
Soft
Start Kit
Remote Mount HWG
(Desuperheater) Kit
TBW, TCW
X
X
X
Accessory Pump Slaving
Module
4
Tranquility®
X
X
X
X
X
X
X
X
X
X
X
ClimateMaster: Declare your personal energy independence.
ClimateMaster Geothermal Heating and Cooling
Thermostats and Service Tools
Thermostats—Communicating
AWC99B01
Internet-connected, Digital, communicating, programmable,
variable stage heat – cool. Configure, monitor and diagnose
system from thermostat or dealer portal on internet.
ONLY USED WITH TRILOGY®.
ATC32U02
Digital, communicating, programmable, 3-stage heat,
2-stage cool. Configure, monitor and diagnose system from
thermostat.
Service Tools—Communicating
ACDU02
Configuration diagnostic tool. For use when communicating
thermostat is not used.
ASVCTOOL01
For Trilogy® units only. Connect to the Trilogy®'s EXM board to
configure, diagnose and update Trilogy® software.
Thermostats—Non-Communicating
ATP32U03/ATP32U04
Programmable, digital, 3 stage heat, 2 stage cool, auxiliary,
fault LED. Use 04 with ClimaDry® units.
ATA22U01
Non-programmable 2 stage heat, 2 stage cool; aux,
emergency, fault LED
Residential Products Technical Guide
5
Accessories
AWC99B01 iGate® Connect, Two-Way Communicating Thermostat
Variable Stage Heating and Cooling
Programmable
Connections for thermostat
terminals to equipment:
EXM Control Board
R
A+
BC
Remote Sensor 1
Remote Sensor 2
iGate™ Connect Thermostat
• Information is remotely available (if you wish) to your dealer
through a dealer portal for remote troubleshooting and
diagnosis
• Secure internet connection keeps your information private
• Easy-to-use, high-resolution color display and intuitive
interface
• Key features:
–Precision +/-1°F (0.5°C) temperature control
–Vacation programming
–Seven-day programming
–Humidity sensing
–Intelligent algorithms that adapt to your home
and preferences
–Fan control
–Hot water control
• Dealer can receive alerts regarding maintenance, inefficient
operations or faults
• Alerts and warning data are viewable from the thermostat
and homeowner/dealer portal
• Real time system performance is stored, which increases the
accuracy of diagnosing issues and results in faster repairs
• "Service Needed" alert displays dealer name, phone
number, model unit/serial number, fault condition and
possible causes
• Secure internet portal keeps your information private
• Accessible with Android and iPhone mobile app
Controls:
R2- R2+ R1- R1+ B-
A+ Gnd 24v
Application:
Internet connected, digital, two-way communicating,
programmable, variable stage heat-cool. Configure, monitor
and diagnose system from thermostat or dealer portal on
internet. The thermostat is only compatible with Trilogy® units.
Features:
Web-Enabled Home Thermostat
• Communicates personal settings and reminders through
the iGate® communication system
• Easy to use, full color, high resolution interface
• Receives notification for routine maintenance
• Sleek, intuitive button control
• Secure internet connection keeps your information private
• Contains Trilogy® unit model, serial number and dealer
contact information
• Service and system performance information is stored in
the thermostat, increasing the accuracy of diagnosis
6
Web Portal Accessible Any Time, Any Where
• Remote login from anywhere, anytime from any device and
adjust settings
• Set personal schedule by day, week or month including
those times when you will be away from home on vacation
or business
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Heat pump control
Auxiliary heat
Programmable fan control
Auto-changeover
Humidity control
Intelligent setback recovery
On-screen contractor information
Configurable min/max set temperature
Switch between Farenheit and Celsius
Configurable upstaging and downstaging
Wireless protocol: B/G/N
Wi-Fi security encryption
Encryption communication over internet
365-day scheduling/7-day programming
Specifications:
Temperature Settings:
• Heat: 55 to 80°F (12 to 27°C)
• Cool: 65 to 95°F (18 to 35°C)
• Display: 40 to 100°F (5 to 37°C)
• Sensitivity: +/-1°F (0.5°C)
• Operating: 32 to 130°F (0 to 55 °C)
Humidity Range:
• Display: 20 to 90% R.H.
• Sensitivity: +/-5% R.H.
• Operating: 5 to 95% R.H. (non-condensing)
Power:
• Power 24 VAC (3VA maximum)
ClimateMaster: Declare your personal energy independence.
ClimateMaster Geothermal Heating and Cooling
ATC32U02 iGate® Communicating Thermostat
Three-Stage Heat / Two-Stage Cool
Programmable
Features (cont.):
6.25 in
[158.8mm]
•
•
•
•
•
•
•
•
•
•
•
4.25 in
[108.0mm]
1.1 in Depth
[27.9mm]
•
•
Mounting:
UP
•
•
C
R
1.50"
[38mm]
A+
3.12"
[80mm]
3.25"
[83mm]
BGND
OD
ID
GND
3.00"
[76mm]
2.12"
[54mm]
•
•
•
•
•
•
- Service warning: Fault condition, current system status
(temp/flow) and possible causes displayed to home
owner, to better inform dealer before site visit
- Service mode: Once on site, in installer mode service
personnel can see fault conditions, possible causes and
temperature/flow/i/o conditions at the time of fault
- Demand reduction - Programmed or triggered by
external signal from utility company
7-day programming
Programmable or non-programmable operation
Four periods per day
ºF or ºC temperature display
12 or 24 hour clock
Individual heat and cool set points
Zero temperature droop performance
Automatic (program mode) or manual (HOLD) operation
Convenient overrides allow temporary set point changes
Selectable differential or proportional integral operation
Set points are permanently held in memory (no batteries
used) and retained during power outages
Room temperature offset adjustment
Progressive Recovery anticipates the time required to
bring the space temperature to the next programmed
event, and brings on the heat pump accordingly
Large backlit dot matrix display is activated whenever a
key is pressed and remains on for 25 seconds
Menu-driven programming with five navigation buttons
(UP/DOWN/LEFT/RIGHT/SELECT) for ease of use
Fault indication with red backlight display
Configurable service interval messages and servicing
contractor contact information
Keypad lockout
Back-plate wiring connections for easy installation
Compatible with AST008 sensor for use as remote and/or
outdoor sensor
Dual fuel capable
0.62"
[16mm]
Specifications:
Electrical Rating:
• Input Power: 18 to 30 VAC, 50/60 Hz
Application:
The ATC32U02 iGate® Communicating Thermostat provides
3 stages heating, 2 stages of cooling, and programmable
temperature control of 24V water-source heat pump
equipment. Allows 4-wire installation with communicating
digital units and advanced configuration, monitoring, control
and diagnostics on the thermostat.
Features:
• 4-Wire Communication with DXM2 or AXM2 UNITS
• Exclusive iGate® System - Configuration, monitoring and
diagnostics at thermostat:
- Configure airflow, entering/leaving water, ∆T,
accessories, unit type
Operating Conditions:
• 32ºF to 104ºF [0ºC to 40ºC]
• 10% to 95% non-condensing
Temperature Settings:
• Set point range: 55ºF to 95ºF [12ºC to 35ºC], +/- 2ºF [1ºC]
• Dehumidification set point range: 15% to 95% RH
• Humidification set point range: 10% to 45% RH
Output Ratings:
• Maximum current for each output is 1.0 Amp (2.0 max.
output total).
Residential Products Technical Guide
7
Accessories
ATC32U02 iGate® Communicating Thermostat
Three-Stage Heat / Two-Stage Cool
Programmable
Packaged Units
Split Units
®
Connection to iGate® Communicating Thermostat and AXM
Communicating Control in Tranquility® Digital Air Handler
iGate Communicating Thermostat Connection
to DXM2 Control
iGate® Thermostat
ATC32U**
DXM2
24Vac Common
C
Comm +
A+
24Vac Hot
R
Comm -
B-
Gnd
A+
B24V
OD
GND
ID
Outdoor
Sensor
(Optiona)
iGate Thermostat
ATC32**
™
Communicating
TAH with
AXM Control
C
A+
C
A+
C
A+
C
A+
R
B-
B-
B-
B-
R
24V
24V
Remote Indoor
Sensor
(Optiona)
See equipment wiring diagram for more details.
8
DXM2 in
Compressor
Section
ClimateMaster: Declare your personal energy independence.
ClimateMaster Geothermal Heating and Cooling
ATP32U03
Three Heat / Two Cool, Manual / Auto Changeover
Programmable
Features (cont.):
6.25 in
[158.8mm]
• Set points are permanently held in memory (no batteries
used) and retained during power outages
• Room temperature offset adjustment
• Progressive Recovery anticipates the time required to
bring the space temperature to the next programmed
event, and brings on the heat pump accordingly
• Large backlit dot matrix display is activated whenever a
key is pressed and remains on for 25 seconds
• Menu-driven programming with five navigation buttons
(UP/DOWN/LEFT/RIGHT/SELECT) for ease of use
• Fault indication with red backlight display
• Configurable service interval messages and servicing
contractor contact information
• Keypad lockout
• Back-plate wiring connections for easy installation
• Exclusive fault identification (When used with CXM
or DXM) displays fault from CXM/DXM board (e.g.
condensate overflow) and suggests possible causes
• Compatible with AST008 sensor for use as remote and/or
outdoor sensor
• Dual fuel capable
4.25 in
[108.0mm]
1.1 in Depth
[27.9mm]
Mounting:
Specifications:
Electrical Rating:
• Input Power: 18 to 30 VAC, 50/60 Hz
UP
C
R
1.50"
[38mm]
A+
3.12"
[80mm]
3.25"
[83mm]
BGND
OD
ID
GND
3.00"
[76mm]
2.12"
[54mm]
Operating Conditions:
• 32ºF to 104ºF [0ºC to 40ºC]
• 10% to 95% non-condensing
Temperature Settings:
• Set point range: 40ºF to 90ºF [4ºC to 32ºC], +/- 2ºF [1ºC]
• Dehumidification set point range: 15% to 95% RH
• Humidification set point range: 10% to 45% RH
Output Ratings:
• Maximum current for each output is 1.0 Amp (2.0 max.
output total).
0.62"
[16mm]
Application:
The ATA32U03 Thermostat provides 3 stages heating, 2
stages of cooling, and programmable temperature control of
24V water-source heat pump equipment.
Features:
•
•
•
•
•
•
•
•
•
•
7-day programming
Programmable or non-programmable operation
Four periods per day
ºF or ºC temperature display
12 or 24 hour clock
Individual heat and cool set points
Zero temperature droop performance
Automatic (program mode) or manual (HOLD) operation
Convenient overrides allow temporary set point changes
Selectable differential or proportional integral operation
Residential Products Technical Guide
9
Accessories
ATP32U03
Three Heat / Two Cool, Manual / Auto Changeover
Programmable
Single-Stage Units
Two-Stage Units with ECM Fan
Connection to CXM Control
CXM
ATP32U03 Thermostat
Compressor
Connection to ECM Control
Y1
Y
Reversing Valve
O
O
Fan
24Vac Hot
24Vac Common
G
G
R
R
C
C
L
W1
AL1
W
Fault LED
Electric Heat
ATP32U03 Thermostat
ECM
Compressor
Y1
Y1
Compressor Stage 2
Reversing Valve
Fan
Y2
Y2
O
O
G
G
24Vac Hot
24Vac Common
Fault LED
R
R
Electric Heat
C
C
L
W1
AL1
W
Units with CXM or DXM board and ECM fan motor
Connection to DXM Control
ATP32U03 Thermostat
Compressor
DXM
Y1
Y2
Reversing Valve
O
Fan
24Vac Hot
24Vac Common
Fault LED
Electric Heat
G
R
C
L
W1
Y1
Note 1
Y2
O/W2
G
R
C
AL1
Field Wiring
Factory Wiring
W
Single stage unit with PSC or belt drive fan motor
Note 1: Y2 may be used for High Speed fan for units with direct drive motor
See equipment wiring diagram for more details
10
ClimateMaster: Declare your personal energy independence.
ClimateMaster Geothermal Heating and Cooling
ATP32U04
Three Heat / Two Cool, Manual / Auto Changeover
Programmable (7 Day) - With Humidity Control
Features (cont.):
6.25 in
[158.8mm]
•
•
•
•
•
•
•
•
4.25 in
[108.0mm]
•
•
•
•
1.1 in Depth
[27.9mm]
•
•
•
•
•
Mounting:
UP
•
C
R
1.50"
[38mm]
A+
3.12"
[80mm]
3.25"
[83mm]
BGND
OD
ID
GND
3.00"
[76mm]
2.12"
[54mm]
0.62"
[16mm]
Application:
The ATP32U04 Thermostat provides 3 stages heating, 2
stages of cooling, and programmable temperature/humidity
control of 24V water-source heat pump equipment.
Features:
• 7-day programming
• Dehumidification output is designed to work with Whole
House Dehumidification Modulating Reheat option or with
ECM fan motor dehumidification mode
• Integrated control of both temperature and relative
humidity
• Integrated control eliminates separate thermostat and
dehumidistat/humidistat
• Thermostat can be programmed to use humidification
output to control a humidifier
• Selectable differential or proportional integral operation
•
Four periods per day
ºF or ºC temperature display
12 or 24 hour clock
Individual heat and cool set points
Zero temperature droop performance
Automatic (program mode) or manual (HOLD) operation
Convenient overrides allow temporary set point changes
Set points are permanently held in memory (no batteries
used) and retained during power outages
Room temperature offset adjustment
Progressive Recovery anticipates the time required to
bring the space temperature to the next programmed
event, and brings on the heat pump accordingly
Large backlit dot matrix display is activated whenever a
key is pressed and remains on for 25 seconds
Menu-driven programming with five navigation buttons
(UP/DOWN/LEFT/RIGHT/SELECT) for ease of use
Fault indication with red backlight display
Configurable service interval messages and servicing
contractor contact information
Keypad lockout
Back-plate wiring connections for easy installation
Exclusive fault identification (When used with CXM
or DXM) displays fault from CXM/DXM board (e.g.
condensate overflow) and suggests possible causes
Compatible with AST008 sensor for use as remote and/or
outdoor sensor
Dual fuel capable
Specifications:
Electrical Rating:
• Input Power: 18 to 30 VAC, 50/60 Hz
Operating Conditions:
• 32ºF to 104ºF [0ºC to 40ºC]
• 10% to 95% non-condensing
Temperature Settings:
• Set point range: 40ºF to 90ºF [4ºC to 32ºC], +/- 2ºF [1ºC]
• Dehumidification set point range: 15% to 95% RH
• Humidification set point range: 10% to 45% RH
Output Ratings:
• Maximum current for each output is 1.0 Amp (2.0 max.
output total).
Residential Products Technical Guide
11
Accessories
ATP32U04
Three Heat / Two Cool, Auto / Manual Changeover
Programmable (7 Day) - Non-Programmable, With Humidity Control
Units with Whole House Dehumidification Reheat
Units with ECM Fan
Connection to ECM Control
Connection to DXM Control (PSC Fan)
ATP32U04 Thermostat
Compressor
Dehumidification
Reversing Valve
Fan
24Vac Hot
24Vac Common
Fault LED
Electric Heat
P1
DXM
Compressor
Compressor Stage 2
Y1
O/W2
Dehumidification
DH
G
O
R
Reversing Valve
Fan
C
24Vac Hot
R
Y1
Y1
DH
H
O
G
R
C
L
AL1
W
W1
ATP32U04 Thermostat
24Vac Common
Fault LED
Electric Heat
Single stage unit with ClimaDry Modulating Reheat Option and PSC fan
DXM
P1
Compressor
Compressor Stage 2
Y1
Dehumidification
DH
Reversing Valve
Fan
24Vac Hot
24Vac Common
Fault LED
Electric Heat
O
Y1
Y2
H
O/W2
G
R
Y2
G
R
C
L
W1
Two-stage unit with ClimaDry Modulating
Reheat Option and DXM board
Field Wiring
Factory Wiring
DH
O
G
R
G
C
C
L
W1
AL1
W
C
AL1
W
Notes:
1) ECM dehumidification mode slows down fan speed in the
cooling mode when dehumidification output from thermostat is
active. Normal heating and cooling fan speeds are not
affected.
2) ECM board DIP switch SW9 must be in dehumid. mode.
Units with Whole House Dehumidification Reheat & ECM Fan
Connection to ECM & DXM Control
ATP32U04 Thermostat
Terminal
Block
ECM
Y1
DXM
Compressor
Compressor Stage 2
Y1
2
Y2
1
Dehumidification
DH
Y2
H
Reversing Valve
O
4
O/W2
Fan
24Vac Hot
G
3
7
R
24Vac Common
Fault LED
C
L
W
6
8
C
AL1
5
W
Electric Heat
R
Single or two-stage unit with ClimaDry Modulating Reheat
Option and DXM board (ECM fan motor)
See equipment wiring diagram for more details
12
Y1
Y2
Y2
Units with CXM or DXM board and ECM fan motor, utilizing
ECM dehumidification mode (w/o ClimaDry option)
Connection to DXM Control
ATP32U04 Thermostat
ECM
ClimateMaster: Declare your personal energy independence.
G
ClimateMaster Geothermal Heating and Cooling
ATA21U01
Two Heat / One Cool
Auto / Manual Changeover - Non-Programmable
For use with Single-Stage Units
Features (cont.):
4.55 in
[115.6mm]
Fan: turns
continuous fan
OFF or ON
Fault Light
Temperature:
increase
• Setup feature allows either “current room temp” or the
“current setpoint” to be displayed.
• Optional safety setpoints ensure that heating and cooling
will occur even if thermostat is in “Off” mode.
• Backplate wiring for easy installation.
Specifications:
Electrical Rating:
• Input Power: 18 to 30 Vac, 50/60 Hz.
3.30 in
[83.8mm]
Temperature:
decrease
0.8 in Depth
[20.3mm]
Mode: Selects system mode - OFF,
HEAT, COOL, EMHEAT, or AUTO
Mounting:
Temperature Settings:
• Setpoint Range: 50°F to 90°F [10°C to 32°C].
• The default setpoint for heating is 70°F [21°C] and for
cooling is 74°F [23°C]. Press the ▲ or ▼ keys to change
the setting. To change between heat and cool settings,
press the mode key until the setting to be changed
appears.
Display Range:
• Display Updates: Controlled: updated every 12 seconds.
• Differential (autochangeover model): 3°F [1.5°C] minimum.
Output Ratings:
• Maximum current for each output is 1 Amp.
Wiring:
Connection to CXM Control
ATA21U01 Thermostat
Application:
The ATA21U01 electronic thermostat provides two-stage
heat / one stage cool, non-programmable temperature
control for 24V water-source heat pump systems.
Features:
•
•
•
•
•
•
•
•
Heat-Off-Cool-Em Heat-Auto System selections.
Fan-On-Auto selections.
°F or °C temperature display.
Configurable automatic or manual changeover operation.
Light emitting diode (LED) for alarm status.
Installer setup options allow for customized applications.
Zero temperature droop performance.
Temperature display adjustment feature provides display
offset for custom applications.
• Setpoints are permanently held in memory (no batteries
used) and retained during power outages.
• Extended fan operation feature can be used to operate fan
for 90 seconds after “Y” turns off.
Y
Compressor
Heating Stage 2 Y2/W
Reversing Valve
O
Fan
G
24Vac Hot
R
24Vac Common
C
Fault LED
L
CXM
Y
Note 1
W
O
G
R
C
AL1
Note 1: Optional Connection for Heating Stage 2 operation, Thermostat "Y2"
option must be configured as "Y2 - Off".This configuration uses the
compressor only for 1st stage heating and compressor plus auxilliary
heat for 2nd stage operation. The thermostat is configured as a two
stage heat / one stage cool thermostat for single speed units with
PSC fan and backup heat. For two-stage units with backup heat or
units with ECM fan and backup heat, a 3 stage heat / 2 stage
cool thermostat is required.
Residential Products Technical Guide
13
Accessories
AZC06CAR
iGate® ClimaZone Zoning Panel
Use with Trilogy Only
TM
Application:
12.0 in
iGate® ClimaZone is the zoning panel for use with the
Trilogy Q-mode System and the iGate® Connect Thermostat.
TM
Features:
• Designed for use with Trilogy® Q-Mode® System
• Compatible with new and existing Trilogy systems
• Accommodates up to six zones with a single zone panel or
up to twelve zones with two zone panels
12.0 in
• Each zone may have up to 3 dampers (Field Supplied)
• iGate® Connect thermostat controls each zone and
provides internet-connected communications
• System configuration and diagnostics available via
ClimateMaster Trilogy PC Service Tool
Specifications:
2.25
2
25 in Depth
Power Supply:
• Zone Panel: 24 VAC Device powered by the Trilogy Unit
• Zone Dampers & Zone Thermostat: Separate 24 VAC
Class 2 18-30 VAC 50/60Hz transformer
Ambient Temperature/Humidity
• Operating: -40F to 176F
• Storage: -40F to 185F
• 5% to 95% RH non-condensing
Zone Thermostats:
• iGate® Connect thermostat is required for each zone
Zone Dampers:
• 24VAC 3-Wire power open/close type dampers required.
Field supplied
Wiring:
• Wire Gauge:
18AWG
20AWG
• Maximum Total Length: 128ft(38m) 80ft(24m)
Mounting:
Screw holes provided on enclosure for either wall or stud
mounting with installer-supplied fasteners.
6.0
6.0
Field wiring
access
Knock outs
for field wiring
Field wiring
access
14
ClimateMaster: Declare your personal energy independence.
22AWG
50ft(15m)
ClimateMaster Geothermal Heating and Cooling
iGate® Smart Tank
Application:
iGate® Smart Tank is the geothermal heating and cooling
industry's first communicating hot water storage tank.
Features:
• All titanium elements for long life and superior
corrosion resistance
• Water temperature sensors (2) continuously monitor
water temperature. When water temperature falls
below desired settings, the iGate® communication
controls signal the heat pump to generate hot water.
• Polyurethane tank is impervious to rust
• Inlet port for incoming water from the heat pump
• Bowl-shaped bottom for more complete sediment
draining
• Full-port ball valve for fast water drainage
• Polyethylene outer jacket
• Well insulated for reduced standby heat loss
• Three capacities: 50 gallon, 85 gallon, 10 gallon
• Watts: 4500
Specifications:
C
3/4" NPT (50 gallon tank)
1" NPT (85 & 105 gallon tank)
A B
1 1/4"
NPT
5 3/4"
Residential Products Technical Guide
15
Accessories
Unit Accessories
TE, TT, TS Models
Item/Description
TZ Models
TAH Models
Auxiliary
Electric
026
Heat
Model*
Auxiliary/
Emergency
Heaters
Part
Number
Internally mounted in vertical
cabinets. Externally mounted on
horizontal cabinets. Sizes 15-20
kW AGM*A and
4-20 kW AGM*C
include internal
circuit breaker.
ETL listed. Circuit
fusing per UL/
NEC. Wiring
harness connections included in
residential units.
AGM4A
AGM4C
AGM5A
AGM5C
AGM8A
AGM8C
AGM10A
AGM10C
024- 036- 042030- 048018
024
030 038 072
042 060
038
049064
AGM12A
AGL10A
AGL10C
AGL15A
AGL15C
AGL20A
AGL20C
Grey area denotes compatibility
Note: Horizontal units rated for zero clearance unit and 1” clearance for the first three feet of duct,
Vertical units rated for zero clearance for both unit and duct.
* Can be used on corresponding TZ, TE, TS and TT models
TE, TT, TS
and TES, TTS Models
Unit Vibration Isolation Pad
018-030
036-072
TZ Models
024-030
036-060
AUQSP2424
High density rubber pad
for quiet operation.
AUQSP2427
AUQSP2732
TE, TT, TS, and TES, TTS Models
Packaged Unit Stand
Ideal for areas that must
have raised equipment
to meet required
mechanical codes.
018-030
ACSVAMBS
ACSVALBS
Packaged Secondary Horizontal Unit Drain Pan
Designed specifically for Tranquility®
Horizontal footprints. Matches the
unit for open ceiling applications
and to meet mechanical codes.
16
036-072
TE, TT, TS
018-030
036-038
042-049
060-072
ASDPADBS
ASDPACBS
ASDPABBS
ASDPAABS
ClimateMaster: Declare your personal energy independence.
ClimateMaster Geothermal Heating and Cooling
Unit Accessories
Pump Slaving Module
Module w/NEMA enclosure - Allows a single
flow controller to be controlled by 2 different
units. Eliminates additional field wiring and
extra relays.
APSM
For use with TS, TBW &
TCW models. Not applicable
with Tranquility® Digital units.
Item Description
Part #
Used With Models
Single phase compressors typically have
starting inrush currents that range from five
to seven times their normal running current.
The SecureStart™ module is designed to reduce inrush current to the compressor by up
to 75% and prevents lights dimming when
the compressor starts up.
13B0045N01
SecureStart™ Compressor Soft Start Kit
All except QE
Remote Thermostat Sensor
Item Description
Part #
Outdoor Temperature Sensor
AST008
Used with Models
ATA21U01, ATP, ATC
thermostats only
Anti-Scald Valve
Item Description
Anti-scald valve be used in DHW systems
where HWG setpoint is 150°F
Part #
Used With Models
AVAS4
All except QE
Communicating Thermostat Configuration Diagnostic Tool (includes case)
Item Description
Part #
For use when communicating thermostat is
not used.
Remote Mount HWG (Desuperheater)
Kit for Tranquility® Outdoor
ACDU02
Used With Models
TE, TZ, TES, TEP
TEP
026
038
049
TTP
064
026
038
049
064
AHWG1BASS
(115 VAC)
*Desuperheater
coil, pump &
controller, mounted in
conditioned space.
AHWG1BGSS
(230 VAC)
AHWG1AASS
(115 VAC)
AHU1BASS
(230 VAC)
*Dealer supplied line set required
Residential Products Technical Guide
17
Accessories
Loop Accessories
Closed Loop Accessories
AFC4I
AFC4C
AFC6F
Hose Kit
AHK5EC
AFC4T
AFC5F
Flow Controller
Double O-Ring Connections
Hose Kit
AHK5PE
Extra Large Closed Loop Accessories
AFCG2B4
AFCG2B3
Open Loop Accessories
Plastic Solenoid
Valve - AVSP5
18
Brass Motorized
Valve - AVMB5
Flow Regulator
AFRV*
P/T Plug
70022002
& 70022003
ClimateMaster: Declare your personal energy independence.
ClimateMaster Geothermal Heating and Cooling
Loop Accessories
Loop Accessories
Part
Number
Description
Composite
3-way
valves
Flow
Controllers
Brass
3-way
valves
Closed Loop
Accessories
Double O-ring
Adaptor
fittings, Set
of Two (One
set Required
for All Flow
Controllers
for Loop
Connection)
Flow Controller
- Hose Kits &
Fittings
vFlow Hose
Kits
Fusion
Insert
Accessory Includes
AFCG1C1
1-GRUNDFOS UP26-99 PUMP
AFCG1C2
1-GRUNDFOS UP26-116 PUMP
AFCG2C1
2-GRUNDFOS UP26-99 PUMP
AFCG2C2
2-GRUNDFOS UP26-116 PUMP
AFCG1B1
1-GRUNDFOS UP26-99 PUMP
AFCG1B2
1-GRUNDFOS UP26-116 PUMP
AFCG2B1
2-GRUNDFOS UP26-99 PUMP
AFCG2B2
2-GRUNDFOS UP26-116 PUMP
AFC5F
1.00” PE SOCKET FUSION
AFC6F
1.25” PE SOCKET FUSION
AFC4I
1.00” BRASS BARD INSERT
AFC6I
1.25” BRASS BARD INSERT
Cam
AFC4C
1.00” CAM LEVER - for flush connections
Thread
AFC4T
1.00” MPT BRASS THREAD
Hose Kit
AHK5EC
Includes double O-ring x 1.00” barb insert for connection to Flow
Controller, 1.00” MPT x 1.00” barb insert el w/PT port for unit
connection, & 10’ of 1.00” rubber hose.
Additional
Hose
ARH510
10’ of 1.00” Rubber Hose
ARH550
50’ of 1.00” Rubber Hose
Elbows
with PT
Ports
AFCM55F
Set of 1" MPT x 1" FPT Elbows with PT ports
Hose Kit
AHK5PE
Includes(2) 1/4” PT Plugs, (12’) 1” ID Black Hose, (8) Stainless
steel hose clamps, (2) Elbow, 1” MPT x 1” Hose Barb w/PT Port,
(1) Fitting Set (2 Fittings), 1-1/4” PE Fusion x 1” Hose Barb Brass,
Crimped, (2) Elbow Insulating Boots w/sealing caps
AVSP5
1.00” FTP, 24 VAC-Solenoid Valve, Plastic
AVMB4
0.75” FTP, 24 VAC-Motorized Valve, Brass w/end switch safety
controls
AVMB5
1” SWT, 24 VAC- Motorized Valve, Brass w/end switch safety
controls
Solenoid & Motorized Valves
Open Loop
Accessories
Flow regulators
Pressure/Tempature Ports
AVMB-PH
Powerhead
AFRV*
2 GPM-10 GPM are Brass 0.75” FPT *Specify GPM when ordering.
Example 6gpm = AFR6 Call Factory for pricing and availibility for
larger than 9 gpm-
70022002
Brass 0.25” MPT - Qty.1
70022003
Brass 0.50" MPT - Qty.1
Residential Products Technical Guide
19
Accessories
Extra Large Loop Accessories
New Geo Loop Pumps are for larger residential projects or small commercial applications where smaller flow controllers can not deliver
desired flow rates. All pumps are 3 speed models for field flow adjustment and are 230 / 1 phase power. GPM and feet of head ratings are
at high speed / maximum capacity.
Description
Extra Large Loop Accessories
Part
Number
Flow Controllers
Closed Loop
Accessories
Double O-ring Adaptor
fittings, Set of Two (One
set Required for All Flow
Controllers for Loop
Connection)
Flow Controller - Hose
Kits & Fittings
20
Brass 3-way
valves
Accessory Includes
AFCG1B3
1-GRUNDFOS UP32-160 PUMP
AFCG2B3
2-GRUNDFOS UP32-160 PUMP
AFCG2B4
2-GRUNDFOS UP60-150 PUMP
Fusion
AFC7F
2.00” PE SOCKET FUSION
Cam
AFC7C
1.50” CAM LEVER - for flush
connections
Thread
AFC8T
2.00” FPT BRASS THREAD
AHK8ES
2” Hose Kit w/ Strainer
AHK8E
2” Hose Kit
Hose Kit
ClimateMaster: Declare your personal energy independence.
ClimateMaster Geothermal Heating and Cooling
Installation Accessories
Installation Accessories
Description
Part Number
AFC93
1" MPT x 1" Aluminum Cam Fitting for the Flush Cart
AFCG1PT
Geo-Prime Tank™
AFCG2PT
Pressure Battery Expansion Tank
AGOFL
Geo-Gooser Kit
AFCG1BT
Geo-Booster
AGOFC
Flush Cart
AG1DC
Functional Geo Display Cart for use at trade show and training events. This
display is intended only for 2 and 3 ton vertical upflow units with an internal pump.
Heat pump not included. This is a drop ship item
Geo-Prime
Tank
The Geo Prime Tank
allows the use of
normal pressurized flow
controllers as a “nonpressurized” ground loop
system. The Prime Tank
installs above the normal
flow controller and
maintains a column of
liquid at the pump’s inlet.
Geo-Booster
Geo Booster is designed
to maintain a minimum
pressure on ground
loop systems that uses
an antifreeze solution.
The internal pump
forces fluid into the
loop system from a one
gallon internal storage
tank if static pressure
drops below 35 PSI.
Pressure
Battery
Pressure Battery/
Expansion Tank is
designed to allow
for expansion and
contraction of the loop.
The tank expands using
an internal diaphragm in
summer and contracts in
the winter to exert/absorb
pressure in the loop.
Flush Cart
Flush Cart is used
during initial loop fill
and flush procedure to
fill the loop and then
circulated to remove any
air or debris in the loop
system.
Geo-Gooser Kit
w/Elbows
Geo Gooser Kit provides
an easy means to repressurize the loop field
by adding liquid into
the loop field through a
pressure / temperature
port without a flush and
fill process.
Geo Display Cart
Functional Geo Display
Cart for use at trade
show and training
events. This display is
intended only for 2 and 3
ton vertical upflow units
with an internal pump.
Heat pump not included.
This is a drop ship item.
Residential Products Technical Guide
21
Accessories
Geothermal Loop Pipe
Geothermal Loop Pipe Features:
• Designed for socket or butt fusion connection
• Internal banding for easy handling and control
• 160 psi
• 50 year warranty
• Coils marked in 2 foot increments
• NSF Geothermal Certification
Material: The material shall maintain a 160 psi Hydrostatic
Design Basis at 73.4°F per ASTM D-2837. This material
shall be a high density, polyethylene 3408 having a cell
classification of PE345434C as specified in ASTM D-3350.
ClimateMaster acknowledges Solvay Polymers, Inc.,Houston,
TX, as the primary supplier of high density polyethylene resin
(K44-15-23) specifically for this use.
Specifications for ClimateMaster Geothermal Loop Pipe &
Fittings
General: All pipe and heat fused materials are manufactured
from a virgin, high density, polyethylene 3408 material
manufactured in accordance with ASTM D-2513 sections 4.1
and 4.2. Pipe shall be manufactured to outside diameters,
wall thickness, and respective tolerances as specified in
ASTM D-3035, D-2447 or F-714.
U-Bend Coils
Spaced Pond
Loop Coils
100’ Pipe Bundle
Part Number
Geothermal Loop Pipe
Pipe
Package
Pipe Length
Diameter
Type
Pipe Type
Coils Per
Pallet
GP4L100
0.75” IPS
100
Bundle 5x20’
SDR11
N/A
GP4C200
0.75” IPS
200
Coil
SDR11
13
GP4C300
0.75” IPS
300
Coil
SDR11
10
GP4C500
0.75” IPS
500
Coil
SDR11
8
GP4C600
0.75” IPS
600
Coil
SDR11
8
GP4C800
0.75” IPS
800
Coil
SDR11
8
GP5L100
1.00” IPS
100
Bundle 5x20’
SDR11
N/A
GP5C300
1.00” IPS
300
Coil
SDR11
10
GP5C500
1.00” IPS
500
Coil
SDR11
6
GP6L100
1.25” IPS
100
Bundle-5x 20’
SDR11
N/A
GP6C100
1.25” IPS
100
Coil
SDR11
14
GP6C300
1.25” IPS
300
Coil
SDR11
14
GP8L100
2.00” IPS
100
Bundle-5x20’
SDR11
N/A
GP8C100
2.00” IPS
100
Coil
SDR11
10
GP8C300
2.00” IPS
300
Coil
SDR11
7
GP4C350U
0.75” IPS
350
2-175’ Coils
SDR11
12
GP4C410U
0.75” IPS
410
2-205’ Coils
SDR11
10
GP4C510U
0.75” IPS
510
2-255’ Coils
SDR11
8
GP5C410U
1.00” IPS
410
2-205’ Coils
SDR11
8
GP5C510U
1.00” IPS
510
2-255’ Coils
SDR11
8
GP5C610U
1.00” IPS
610
2-305’ Coils
SDR11
8
GP5C710U
1.00” IPS
710
2-355’ Coils
SDR11
8
GP5C810U
1.00” IPS
810
2-405’ Coils
SDR11
8
GP4S300
0.75” IPS
SDR11
5
Coils with U-Bend Attached
Spaced Pond Loop Coil
22
300
Coil
ClimateMaster: Declare your personal energy independence.
ClimateMaster Geothermal Heating and Cooling
Geothermal Fittings
Part Number
Description
Fusion Coupling
GFC44
GFC55
GFC64
GFC65
GFC66
GFC85
GFC86
GFC88
0.75”
1.00”
1.25”
1.25”
1.25”
2.00”
2.00”
2.00”
x
x
x
x
x
x
x
x
0.75”
1.00”
0.75”
1.00”
1.25”
1.00”
1.25”
2.00”
Box Quantity
120
80
50
50
40
30
30
30
Coupling
Elbow
Fusion Elbow 90 degrees
GFE44
GFE54
GFE55
GFE64
GFE66
GFE88
0.75”
1.00”
1.00”
1.25”
1.25”
2.00”
x
x
x
x
x
x
0.75”
0.75”
1.00”
0.75”
1.25”
2.00”
70
50
50
100
90
30
Tee
Fusion Tee
GFT444
GFT555
GFT644
GFT655
GFT664
GFT665
GFT884
GFT885
GFT888
0.75”
1.00”
1.25”
1.25”
1.25”
1.25”
2.00”
2.00”
2.00”
x
x
x
x
x
x
x
x
x
0.75”
1.00”
0.75”
1.00”
1.25”
1.25”
2.00”
2.00”
2.00”
x
x
x
x
x
x
x
x
x
0.75”
1.00”
0.75”
1.00”
0.75”
1.00”
0.75”
1.00”
2.00”
75
50
70
60
60
60
25
25
25
U-Bend Fitting
Cap
Fusion U-Bend Fitting
GFEU44
GFEU55
GFEU66F
GFEU66M
GFU44
GFU55
GFU66
0.75” x 0.75” Street el
1.00” x 1.00” Street el
1.25” x 1.25” Short female
1.25” x 1.25” Short male
0.75” U-Bend Bullet
1.00” U-Bend Bullet
1.25” U-Bend Bullet
120
200
90
90
1
1
1
Bullet Fitting
Header
Fusion Cap
GFCP4
GFCP5
GFCP6
GFCP8
0.75”
1.00”
1.25”
2.00”
160
160
100
30
Fusion Header - Pre Assembled
GFK644K02
GFK644K03
GFK644K04
GFK644K05
1.25”
1.25”
1.25”
1.25”
Inlet
Inlet
Inlet
Inlet
x
x
x
x
(3)
(4)
(5)
(6)
0.75”
0.75”
0.75”
0.75”
Outlets
Outlets
Outlets
Outlets
15
20
20
20
Residential Products Technical Guide
23
Accessories
Geothermal Fittings
Part Number
GFMT453
GFMT553
Description
Box Quantity
Fusion X Male Nominal Thread X FPT
0.75” x 1.00” MNT x 0.50” FPT
1.00” x 1.00” MNT x 0.50” FPT
40
50
Swivel Adaptor
Fusion X Male Swivel Adapter - For use w/90B0001N02
GFMC56S
GFMC66S
1.00” Fusion x 1.25” Brass Swivel NPT
1.25” Fusion x 1.25” Brass Swivel NPT
30
20
Fusion X Male Adapter
GFMA44
GFMA55
GFMA65
GFMA66
GFMA88
0.75”
1.00”
1.25”
1.25”
2.00”
x
x
x
x
x
0.75”
1.00”
1.00”
1.25”
2.00”
MPT Brass
MPT Brass
MPT Brass
MPT Brass
MPT Brass
30
20
25
30
30
Male Adaptor Tee
Fusion Adaptor, Hose Barb
GFFA65H
24
1.25" Socket Fusion x 1" Hose Barb
Male Adaptor
30
ClimateMaster: Declare your personal energy independence.
ClimateMaster Geothermal Heating and Cooling
Socket Fusion Tools
Socket Fusion Tools
Part Number
Description
Heating Tool
HVTD48
Fusion Tool, Double Socket
Face
Socket Face
HSF4P
0.75” IPS
HSF5P
1.00” IPS
HSF6P
1.25” IPS
HSF8P
2.00” IPS
Cold Ring
HCR4P
0.75” IPS
HCR5P
1.00” IPS
HCR6P
1.25” IPS
HCR8P
2.00” IPS
Combo Depth Gauge and Chamfer Tool
HDC4P
0.75” IPS
HDC5P
1.00” IPS
HDC6P
1.25” IPS
HDC8P
2.00” IPS
Fusion Tool Accessories
Fusion Tool Mounting
Bracket
HMB
HFT
Fusion Timer
HHB
Fusion Tool Cover
HS500
Tempstik 500*F
HS525
Tempstik 525*F
Complete Fusion Kits
HHAK46WDP
0.75” & 1.25” IPS - Double
HHAK468WDP
0.75”, 1.00”, 1.25” & 2.00”
IPS - Double
Kits Include: Heating tool, socket face set,
depth gauge, cold rings, hex keys, tubing cutter,
screwdriver, tempsticks, timer, tool bag cover,
cotton wipe bag.
Residential Products Technical Guide
25
Accessories
Service Tools
Item
Part Number
Description
Temperature Measurement
ADT160
Digital Thermometer for use with P/T Ports
Pressure Measurement
APG100
Pressure Gauge, 0-100 psi
Gauge Probe Adapter
APTGA
P/T Port Adapter for use with APG100
Alcohol Antifreeze Tester (.9-1)
AHYDA
Specific Gravity Hydrometer
Glycol Antifreeze Tester (1-1.07)
AHYDG
Specific Gravity Hydrometer
Water Pressure Gauge
AG1PG
Water Pressure Gauge for use with Digital units
Control Checker
ATS007
Monitor/checks safety controls
AC Magnetic Field Indicator
AACMFI
Check pump operation
Pressure
Gauge
and Adapter
Antifreeze Tester
Digital Thermometer
Service Parts Kit
Item
Part Number
Residential Service Parts Kit
ASPK
Residential Service Parts Kit
Residential Service Parts Kit
Residential Service Parts Kit
ASPK1
ASPK2
ASPK3
Description
Designed to provide inexpensive parts for dealers. Contains emergency
installation and service parts for Residential units and Flow Controllers.
ASPK plus DXM2 and related harnesses
ASPK plus DXM2 and related harnesses plus ACDU02
Service tool kit for Trilogy® (QE)
Cabinet Samples
Part Number
Description
SAMPLECABTZV036
SAMPLECABTEV038
SAMPLECABTTV026
SAMPLECABTTV049
SAMPLECABTBW060
Low cost, lightweight display unit to take to home shows, county fairs, or for use in a showroom.
Cabinet Sample
26
ClimateMaster: Declare your personal energy independence.
ClimateMaster Geothermal Heating and Cooling
Filters
MERV 11 Replacement Filters
TEH, TTH & TSH - Horizontal Units
018 - 030
036 - 038
042 - 049
060 - 072
TEV/D, TTV/D & TSV/D - Vertical Units
2 - 18 x 18
76B0005N01
018
1 - 24 x 24
76B0005N08
1 - 12 x 20
76B0005N02
024 - 030
1 - 24 x 28
76B0005N14
1 - 20 x 25
76B0005N09
036 - 038
1 - 28 x 30
76B0005N15
1 - 18 x 20
76B0005N04
042 - 049
1 - 30 x 32
76B0005N19
1 - 20 x 24
76B0005N07
060 - 072
1 - 30 x 36
76B0005N20
2 - 20 x 24
76B0005N07
MERV 8 Replacement Filters
TZH - Horizontal Units
TZV - Vertical Units
024 - 030
1 - 18 x 24
76B0015N07
024 - 030
1 - 20 x 20
76B0015N01
036 - 042
1 - 14 x 20
76B0015N05
Qty 2
036 - 042
1 - 24 x 24
76B0015N02
048 - 060
1 - 20 x 38
76B0015N06
and
76B0015N05
048 - 060
1 - 28 x 28
76B0015N03
These are nominal sizes: actual sizes are slightly smaller.
Residential Products Technical Guide
27
Accessories
Revision History
Date
Page #
Description
3 Feb., 16
Various
iGate ClimaZone Added
01 Sept., 15
4
Updated Water-to-Water Section of Table
08 June, 15
3
Updated IAQ Filter Photo
03 Oct., 14
All
Updated
20 Feb. 13
All
Updated
16 July 12
553-554
28 May, 10
558
12 May, 09
556, ATP32U04 Page
05 June, 08
All
Reformatted Document Size
04 Mar, 07
560
Changed Part Number and Description for Outdoor
Split Flow Controller Transition Fittings
04 Mar, 07
561
Discontinued 90B0001N02 Fitting
01 Oct, 06
All
First Published
ATC32U01 Added
New Rev. C Auxiliary/Emergency Heaters Added
New Thermostat Model Added
7300 S.W. 44th Street
Oklahoma City, OK 73179
Phone: 405-745-6000
*RP1008*
Fax: 405-745-6058
climatemaster.com
RP1008
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time for order may be
changed without notice and may not be as described herein. Please contact ClimateMaster’s Customer Service Department at 1-405-745-6000
for specific information on the current design and specifications. Statements and other information contained herein are not express warranties
and do not form the basis of any bargain between the parties, but are merely ClimateMaster’s opinion or commendation of its products.
© ClimateMaster, Inc. 2008
28
ClimateMaster: Declare your personal energy independence.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF