G100/G200/G1000 G1200 Quick Start Guide

G100/G200/G1000 G1200 Quick Start Guide
GSeries_QuickStartGuide.book Page i Thursday, March 3, 2005 1:33 PM
®
G100/G200/G1000
G1200 Quick Start
Guide
GSeries_QuickStartGuide.book Page ii Thursday, March 3, 2005 1:33 PM
Internet Security Systems, Inc.
6303 Barfield Road
Atlanta, Georgia 30328-4233
United States
(404) 236-2600
http://www.iss.net
© Internet Security Systems, Inc. 2003-2005. All rights reserved worldwide. Customers may make reasonable numbers of
copies of this publication for internal use only. This publication may not otherwise be copied or reproduced, in whole or in
part, by any other person or entity without the express prior written consent of Internet Security Systems, Inc.
Patent pending.
© Intel Corporation, 2002.
Internet Security Systems, System Scanner, Wireless Scanner, SiteProtector, Proventia, ADDME, AlertCon, ActiveAlert,
FireCell, FlexCheck, Secure Steps, SecurePartner, SecureU, and X-Press Update are trademarks and service marks, and the
Internet Security Systems logo, X-Force, SAFEsuite, Internet Scanner, Database Scanner, Online Scanner, and RealSecure
registered trademarks, of Internet Security Systems, Inc. Network ICE, the Network ICE logo, and ICEpac are trademarks,
BlackICE a licensed trademark, and ICEcap a registered trademark, of Network ICE Corporation, a wholly owned
subsidiary of Internet Security Systems, Inc. SilentRunner is a registered trademark of Raytheon Company. Acrobat and
Adobe are registered trademarks of Adobe Systems Incorporated. Certicom is a trademark and Security Builder is a
registered trademark of Certicom Corp. Check Point, FireWall-1, OPSEC, Provider-1, and VPN-1 are registered trademarks
of Check Point Software Technologies Ltd. or its affiliates. Cisco and Cisco IOS are registered trademarks of Cisco Systems,
Inc. HP-UX and OpenView are registered trademarks of Hewlett-Packard Company. IBM and AIX are registered
trademarks of IBM Corporation. InstallShield is a registered trademark and service mark of InstallShield Software
Corporation in the United States and/or other countries. Intel and Pentium are registered trademarks of Intel. Lucent is a
trademark of Lucent Technologies, Inc. ActiveX, Microsoft, Windows, and Windows NT are either registered trademarks
or trademarks of Microsoft Corporation. Net8, Oracle, Oracle8, SQL*Loader, and SQL*Plus are trademarks or registered
trademarks of Oracle Corporation. Seagate Crystal Reports, Seagate Info, Seagate, Seagate Software, and the Seagate logo
are trademarks or registered trademarks of Seagate Software Holdings, Inc. and/or Seagate Technology, Inc. Secure Shell
and SSH are trademarks or registered trademarks of SSH Communications Security. iplanet, Sun, Sun Microsystems, the
Sun Logo, Netra, SHIELD, Solaris, SPARC, and UltraSPARC are trademarks or registered trademarks of Sun
Microsystems, Inc. in the United States and other countries. All SPARC trademarks are used under license and are
trademarks or registered trademarks of SPARC International, Inc. in the United States and other countries. Adaptive
Server, SQL, SQL Server, and Sybase are trademarks of Sybase, Inc., its affiliates and licensers. Tivoli is a registered
trademark of Tivoli Systems Inc. UNIX is a registered trademark in the United States and other countries, licensed
exclusively through X/Open Company, Ltd. All other trademarks are the property of their respective owners and are used
here in an editorial context without intent of infringement. Specifications are subject to change without notice.
Disclaimer: The information contained in this document may change without notice, and may have been altered or
changed if you have received it from a source other than ISS or the X-Force. Use of this information constitutes acceptance
for use in an “AS IS” condition, without warranties of any kind, and any use of this information is at the user’s own risk.
ISS and the X-Force disclaim all warranties, either expressed or implied, including the warranties of merchantability and
fitness for a particular purpose. In no event shall ISS or the X-Force be liable for any damages whatsoever, including direct,
indirect, incidental, consequential or special damages, arising from the use or dissemination hereof, even if ISS or the
X-Force has been advised of the possibility of such damages. Some states do not allow the exclusion or limitation of
liability for consequential or incidental damages, so the foregoing limitation may not apply.
Reference herein to any specific commercial products, process, or service by trade name, trademark, manufacturer, or
otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by Internet Security
Systems, Inc. The views and opinions of authors expressed herein do not necessarily state or reflect those of Internet
Security Systems, Inc., and shall not be used for advertising or product endorsement purposes.
Links and addresses to Internet resources are inspected thoroughly prior to release, but the ever-changing nature of the
Internet prevents Internet Security Systems from guaranteeing the content or existence of the resource. When possible, the
reference contains alternate sites or keywords that could be used to acquire the information by other methods. If you find a
broken or inappropriate link, please send an email with the topic name, link, and its behavior to support@iss.net.
March 3, 2005
DOC-QSG-PROVIPAG-005-A
GSeries_QuickStartGuide.book Page iii Thursday, March 3, 2005 1:33 PM
Contents
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
About the Proventia G Intrusion Prevention Appliances
How to Use Proventia G Appliances Documentation . .
Conventions Used in this Guide . . . . . . . . . . . . . . . .
.....................................
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. .v
. vi
. vii
. viii
. .x
Chapter 1: Connecting the Appliance. . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the Appliance . . . . . . . . . . . . . . . . . . .
Proventia G Appliances Front and Back Panels . . .
Connecting the Cables and Starting the Appliance
Connecting the External Bypass Unit. . . . . . . . . .
Inline Deployment Scenarios . . . . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
1
. 1
. 2
. 3
. 6
12
14
Chapter 2: Configuring the Appliance
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
17
17
18
20
27
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
29
29
30
31
37
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
39
Overview . . . . . . . . . . . . . . . . . . . . . . .
What You Need to Know Before You Start
Logging On and Configuring the Appliance .
Connecting to the Management Console . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Chapter 3: Reinstalling the Appliance
Overview . . . . . . . . . . . . .
Reinstallation Requirements
Reinstalling the Appliance . .
Getting Technical Support . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Proventia G100/G200/G1000/G1200 Quick Start Guide
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
iii
GSeries_QuickStartGuide.book Page iv Thursday, March 3, 2005 1:33 PM
Contents
iv
GSeries_QuickStartGuide.book Page v Thursday, March 3, 2005 1:33 PM
Preface
Overview
Introduction
This guide describes the procedures for connecting, starting, and
configuring the Proventia G100/G200/G1000 or G1200 Intrusion
Prevention Appliances. These appliances are inline intrusion prevention
systems (IPS) that automatically block malicious attacks while preserving
network bandwidth and availability.
Audience
This guide is intended for users of Proventia G100/G200/G1000 or G1200
model Intrusion Prevention Appliances.
In this guide
The Proventia G100/G200/G1000/G1200 Quick Start Guide includes
information about the following topics:
●
installing the appliance hardware
●
configuring the appliance software
●
reinstalling the appliance software
Proventia G100/G200/G1000/G1200 Quick Start Guide
v
GSeries_QuickStartGuide.book Page vi Thursday, March 3, 2005 1:33 PM
Preface
About the Proventia G Intrusion Prevention Appliances
Introduction
Proventia G
Intrusion Prevention
appliances
Proventia G Intrusion Prevention appliances offer the following intrusion
prevention technologies:
●
three modes of operation
●
firewall rules
●
dynamic blocking response
●
drop response
●
agent settings for processing traffic
Use the Proventia G Intrusion Prevention appliances to do the following:
●
configure packet captures
●
configure firewall rules
●
configure operation modes
●
configure appliance settings
●
review event details for dynamic blocking and drop responses
Note: The Proventia G Appliance Setup Utility is your local
configuration interface. Use this tool to configure your appliance
configuration settings. Use the SiteProtector management console to
manage the Proventia G100, G200, G1000, and G1200 appliances.
vi
GSeries_QuickStartGuide.book Page vii Thursday, March 3, 2005 1:33 PM
How to Use Proventia G Appliances Documentation
How to Use Proventia G Appliances Documentation
Using this guide
Use this guide to install and configure Proventia G Intrusion Prevention
Appliances.
Related publications For the latest available appliance documentation, refer to the online Help
found in the SiteProtector management console and the Readme files
associated with each appliance release.
For information about how to use the appliance, see the following:
●
Proventia G Series Appliances User Guide
This document is available on the ISS Web site at the following
location:
http://www.iss.net/support/documentation/
Proventia G100/G200/G1000/G1200 Quick Start Guide
vii
GSeries_QuickStartGuide.book Page viii Thursday, March 3, 2005 1:33 PM
Preface
Conventions Used in this Guide
Introduction
This topic explains the typographic conventions used in this guide to
make information in procedures and commands easier to recognize.
In procedures
The typographic conventions used in procedures are shown in the
following table:
Convention
What it Indicates
Examples
Bold
An element on the graphical
user interface.
Type the computer’s
address in the IP Address
box.
Select the Print check box.
Click OK.
SMALL CAPS
A key on the keyboard.
Press ENTER.
Press the PLUS SIGN (+).
Constant
width
A file name, folder name,
path name, or other
information that you must
type exactly as shown.
Save the User.txt file in
the Addresses folder.
Type IUSR__SMA in the
Username box.
Constant
width
italic
A file name, folder name,
path name, or other
information that you must
supply.
Type Version number in
the Identification
information box.
Æ
A sequence of commands
From the taskbar, select
from the taskbar or menu bar. StartÆRun.
On the File menu, select
UtilitiesÆCompare
Documents.
Table 1: Typographic conventions for procedures
viii
GSeries_QuickStartGuide.book Page ix Thursday, March 3, 2005 1:33 PM
Conventions Used in this Guide
Command
conventions
The typographic conventions used for command lines are shown in the
following table:
Convention
What it Indicates
Examples
Constant
width bold
Information to type in exactly
as shown.
md ISS
Italic
Information that varies
according to your
circumstances.
md your_folder_name
[]
Optional information.
dir [drive:][path]
[filename] [/P][/W]
[/D]
|
Two mutually exclusive
choices.
verify [ON|OFF]
{}
A set of choices from which
you must choose one.
% chmod {u g o
a}=[r][w][x] file
Table 2: Typographic conventions for commands
Proventia G100/G200/G1000/G1200 Quick Start Guide
ix
GSeries_QuickStartGuide.book Page x Thursday, March 3, 2005 1:33 PM
Preface
x
GSeries_QuickStartGuide.book Page 1 Thursday, March 3, 2005 1:33 PM
Chapter 1
Connecting the Appliance
Overview
Introduction
This chapter contains procedures for connecting Proventia G Intrusion
Prevention appliances.
In this chapter
This chapter contains the following topics:
Topic
Page
Installing the Appliance
2
Proventia G Appliances Front and Back Panels
3
Connecting the Cables and Starting the Appliance
6
Connecting the External Bypass Unit
12
Inline Deployment Scenarios
14
Proventia G100/G200/G1000/G1200 Quick Start Guide
1
GSeries_QuickStartGuide.book Page 2 Thursday, March 3, 2005 1:33 PM
Chapter 1: Connecting the Appliance
Installing the Appliance
Introduction
Box contents
2
There are two options for installing Proventia G appliances in a rack
mount or cabinet system. Instruction sheets are located in your appliance
packaging.
●
sliding rail for 2U appliances
●
mid-mount rack for 1U and 2U appliances
The Proventia G appliance packaging includes the following:
●
AC or DC power cable(s)
●
sliding rail kit (option 1)
●
mid-mount rack kit (option 2)
●
appliance recovery CD
●
RJ-45 to DB9 serial cable
●
strain relief
●
warranty statement
●
bezel cover with keys
●
mouse/keyboard Y-cable
●
crossover connector and patch cable (copper only)
Proventia G Appliances Front and Back Panels
Proventia G Appliances Front and Back Panels
Introduction
This topic identifies the parts of a Proventia G100, G200, G1000, and
G1200 appliance. The front and back panel figures have descriptions for
each item.
Front panel diagram The Proventia G100, G200, G1000, G1200 front panel is shown in Figure 1:
A B
E F
C D
G
H
I
L
K
J
Figure 1: G100/G200/G1000/G1200 appliance front panel
Front panel legend
The front panel of a Proventia G100, G200, G1000, G1200 appliance
includes the following:
●
A (2) - Management Interface LED
●
B (1) - RSKill Interface LED
●
C - Power Button
●
D - Power LED
●
E - Hard Drive Activity LED
●
F - Fault LED
●
G - System ID LED
●
H - System ID Button
●
I - Reset Button
●
J - USB (unused)
●
K - Unused
●
L - Video
Proventia G100/G200/G1000/G1200 Quick Start Guide
3
GSeries_QuickStartGuide.book Page 4 Thursday, March 3, 2005 1:33 PM
Chapter 1: Connecting the Appliance
Caution: You must operate this unit with the top cover installed to ensure
proper cooling.
Note: A Fault LED light generally does not indicate a problem with the
appliance itself. The light can appear if the power supply is not plugged
in.
Back panel diagram
(G100/G200)
Port
A
USB
Port
The Proventia G100 /G200 (1U) back panel is shown in Figure 2:
Port
B
RSKill
Interface (2)
Management
Interface (1)
Video
AC
Power
Serial
Port
USB
Port
Keyboard
Strain
Relief
Release
Lever
Figure 2: G100/G200 appliance back panel
4
GSeries_QuickStartGuide.book Page 5 Thursday, March 3, 2005 1:33 PM
Proventia G Appliances Front and Back Panels
Back panel diagram
(G1000/G1200)
The network card is on the right side of the Proventia G1000 appliance.
The Proventia G1200 appliance has eight ports. The Proventia G1200
offers AC or a DC power option. The Proventia G1000/G1200 (2U) back
panel is shown in Figure 3:
Note: The AC power option is shown in Figure 3. The DC power
information is shown in Figure 4 on page 7.
1a
1b
Strain
Relief
Monitoring
Ports
Monitoring
Ports
A, B
C, D
Release
Lever 1c
E, F
G, H
Kill
Interface (2)
This socket powers this module
AC
Power
USB
Port
Management
Interface (1)
Video
Serial
Port
USB
Port
Keyboard
SCSI
Figure 3: G1000/G1200 appliance back panel
Proventia G100/G200/G1000/G1200 Quick Start Guide
5
GSeries_QuickStartGuide.book Page 6 Thursday, March 3, 2005 1:33 PM
Chapter 1: Connecting the Appliance
Connecting the Cables and Starting the Appliance
Introduction
This topic provides instructions for connecting cables and starting a
Proventia G Intrusion Prevention appliance.
Important: ISS recommends that the SiteProtector or remote access
computer(s) that communicate with the appliance (this occurs through
the management port, port 1) are all on the same logical side of the
network as the management port. If network traffic is unable to traverse
the appliance’s NIC and the SiteProtector and remote access computer(s)
are not on the same logical side as the management port, they will not be
able to communicate with the appliance.
Installing the
appliance
You can use a VT100-compatible terminal emulation program, such as
Hyperterminal, to install the appliance. You can also connect the
appliance to a keyboard and monitor.
Connecting the AC
power cord
The Proventia G100/G200 (1U) appliances come with one AC power
connector. The Proventia G1000/G1200 (2U) appliances come with dual
standard AC power connectors and a DC power option (G1200 only). To
connect the AC power cord(s):
1. Press the strain relief into the platform hole until it snaps into place.
2. Place the power cord into the loop. Leave some slack in the power
cord between the strain relief and the power supply.
3. Pull the tab to secure the power cord in the loop.
4. Insert the female end the power cord into the back of the appliance as
shown in Figure 2 and Figure 3.
5. Insert the male end of the power cord into a standard AC power
supply.
DC power supply
6
The DC power supply used with the Proventia G1200 appliance uses a -48
to -60 VDC input switching power subsystem, which provides up to 470
Watts with -48 to -60 VDC input and with current and remote sense
regulation. The power subsystem consists of one or two 470-Watt power
supply modules. A system with two modules forms a redundant, hotswappable (1+1) power subsystem.
GSeries_QuickStartGuide.book Page 7 Thursday, March 3, 2005 1:33 PM
Connecting the Cables and Starting the Appliance
Note: The DC power supply is only available for the Proventia G1200
appliance.
Back panel diagram
(G1200)
The Proventia G1200 appliance has eight ports. DC power option is only
offered on the Proventia G1200 appliance. The Proventia G1200 (2U) back
panel is shown in Figure 4:
Figure 4: G1200 appliance back panel with DC power option
DC power supply
features
The DC power supply includes the following features:
●
470-Watt output capability in full DC input voltage range
●
power good indication LEDs
●
predictive failure warning
●
iInternal cooling fans with multi-speed capability
Proventia G100/G200/G1000/G1200 Quick Start Guide
7
GSeries_QuickStartGuide.book Page 8 Thursday, March 3, 2005 1:33 PM
Chapter 1: Connecting the Appliance
Interface
requirements for
DC power
●
remote sense of 3.3-Volt, 5-Volt, and 12-Volt DC outputs
●
“DC_OK” circuitry for brown-out protection and recovery
●
built-in load sharing capability
●
built-in overloading protection capability
●
onboard field replaceable unit (FRU) information
●
I2C interface for server management functions
●
integral handle for insertion/extraction
Table 3 identifies the interface requirements for DC power:
Interface
Description
DC Input
The DC power source may produce hazardous voltage levels
exceeding -60 VDC and high energy levels above 240VA that
may cause electric shock or burns. All DC input connections
should be made only by a qualified service person to prevent
injury. All wiring terminals connected to the DC input terminal
block must be fully insulated with no exposed bare metal.
DC Output
Connectors
The power subsystem DC power and control signals are
connected to the server system by means of a wire harnesses
when the power supply modules are inserted into the power
subsystem enclosure. The safety ground pin of the power
supply module is the first pin to connect and the last to
disconnect when the module is being inserted or removed from
the power subsystem housing. In addition to the 5-V Standby, 12 V, +3.3 V, +5 V and +12 VDC outputs, the following signals
and output pins are included:
•
+3.3 VDC remote sense
•
+5 VDC remote sense
•
+12 VDC remote sense
•
Remote sense return
•
Power Subsystem On (DC PWR enable)
•
Power Good
Table 3: Interface requirements for DC power
8
GSeries_QuickStartGuide.book Page 9 Thursday, March 3, 2005 1:33 PM
Connecting the Cables and Starting the Appliance
DC power supply
module LED
indicators
There is a single bi-color LED to indicate power supply status that is
visible on the back of the system. Table 4 shows the conditions confirmed
by the LED indicators.:
Power Supply Condition
Power Supply LED
No DC power to all PSUs
OFF
No DC power to this PSU only
AMBER
DC present/Only Standby Outputs On
BLINK GREEN
Power supply DC outputs ON and OK
GREEN
Current limit
AMBER
Power supply failure (OTP, OCP, OVP, UV)
AMBER
Table 4: DC power supply LED status conditions
Note: S Failure, PS Presence, PS Predictive Fail, +12 V Mon, +5 V Mon, and the 5
V Standby rails failure are being monitored via an I2C interface chip.
DC input voltage
specification
The power supply will operate within all specified limits over the input
voltage range outlined in the Table 5. The power supply will power-off if
the DC input is less than -34 VDC.
Parameter
Minimum
Tolerance
Nominal
Rating
Maximum
Tolerance
Maximum
Input Current
Voltage
-38VDC
-48 to -60VDC
-75VDC
17.0 Amps
Table 5: DC input voltage range
DC output current
specifications
The combined output power of all outputs will not exceed 450 W. The
power supply meets both static and dynamic voltage regulation
requirements for the minimum dynamic loading conditions. The power
supply meets only the static load voltage regulation requirements for the
minimu1. Combined 3.3V/5V shall not exceed 0A.
Proventia G100/G200/G1000/G1200 Quick Start Guide
9
GSeries_QuickStartGuide.book Page 10 Thursday, March 3, 2005 1:33 PM
Chapter 1: Connecting the Appliance
Each output has a maximum and minimum current rating, as shown in
Table 6.
Voltage
Current Rating
+3.3 VDC Output
20 Amp Max1
+5 VDC Output
26 Amp Max1
+12 V1DC Output
16 Amp Max2
+12 V2DC Output
12.0 Amp Max2
+12 V3DC Output
12.0 Amp Max2
-12 VDC Output
0.5 Amp Max
+5 VDC Standby
2.0 Amp Max
Output balancing
Total combined output power of all output shall not
exceed 450 W.
DC Line Voltage
-48VDC to –60VDC
DC Input Current
17.0 Amp maximum
Table 6: DC output voltage range
Note: 1. Combined 3.3V/5V shall not exceed 150W. 2. Maximum
continuous load on the combined 12V output shall not exceed 25A. Peak
load on the combined 12V output shall not exceed 30A for greater than 10
seconds.
Connecting the
appliance to a
computer or laptop
To connect the appliance to a computer or laptop:
1. Plug one end of the serial cable into the serial port on the back of the
appliance as shown in Figure 2 on page 4 and Figure 3 on page 5.
2. Plug the other end of the serial cable into the serial port on your
computer or laptop.
3. Use a VT100-compatible terminal emulation program, such as
Hyperterminal, to create a connection to the appliance with the
following settings:
10
GSeries_QuickStartGuide.book Page 11 Thursday, March 3, 2005 1:33 PM
Connecting the Cables and Starting the Appliance
Note: If you are not using the Hyperterminal program, then your settings
in Table 7 may be different. For more information, refer to the
documentation for your program.
Setting
Value
Bits per second
9600
Data bits
8
Parity
None
Stop bits
1
Flow control
None
Communications Typically COM1, but this depends on the computer you
Port
are using
Table 7: Hyperterminal settings
Setting up terminal
emulation
To set up the terminal emulation:
1. In the Hyperterminal application, go to FileÆ PropertiesÆ Settings.
2. Select Emulation = VT100.
3. Click OK.
Connecting the
network cable
To connect the network cable:
1. Connect the management interface on the back panel to the network
you will use to manage it.
2. Connect the network cables to correspond with the operation mode
(inline or passive) you plan to use for the appliance.
Note: If you configure the appliance to operate in inline protection or
inline simulation modes, see “Inline Deployment Scenarios” on
page 14.
3. If you are using passive mode, then use the kill interface to connect
the appliance to the network and send the RSKill response for events,
and use detection port A to connect to one hub, SPAN port, or tap.
Note: The appliance still aggregates full-duplex traffic with a fullduplex tap set up to use both ports A and B. The cable and coupler
will not be used. The appliance can monitor a total of one segment
despite the existence of two ports (A and B).
Proventia G100/G200/G1000/G1200 Quick Start Guide
11
GSeries_QuickStartGuide.book Page 12 Thursday, March 3, 2005 1:33 PM
Chapter 1: Connecting the Appliance
Connecting the External Bypass Unit
Introduction
This topic explains how to connect the external bypass unit to a Proventia
G fiber or copper-fiber appliance. The external bypass unit monitors the
appliance and ensures that network traffic continues to pass if the
appliance fails or loses power.
Included items
The bypass unit box contains the following items:
Single Bypass Unit
Dual Bypass Unit
One USB cable
Two USB cables
Two fiber cables
Four fiber cables
Bezel cover with keys
Bezel cover with keys
Proventia G100/G200/G1000/G1200
Quick Start Guide
Proventia G100/G200/G1000/G1200
Quick Start Guide
Additional network
cables required
You must have two additional network cables to connect a bypass unit to
a network switch/router. This shipment does not include these cables.
Connecting the
cables
To connect the bypass unit to the appliance:
1. Connect the fiber cables from the network ports on the bypass unit to
network switch/routers.
Important: Verify that traffic flows before you proceed with Step 2.
2. Connect the fiber cables (included with shipment) from the appliance
ports on the bypass unit to the corresponding ports on the back of the
appliance.
3. Connect the USB cable from the USB port on the bypass unit to the
USB port on the back of the appliance.
12
GSeries_QuickStartGuide.book Page 13 Thursday, March 3, 2005 1:33 PM
Connecting the External Bypass Unit
Configuration
diagram
Figure 5 illustrates the bypass unit to appliance configuration:
Note: Internet Security Systems recommends that the connection ports
on the internal bypass unit and the appliance face the back of the rack for
easy connectivity.
Figure 5: Bypass unit to appliance configuration
Proventia G100/G200/G1000/G1200 Quick Start Guide
13
GSeries_QuickStartGuide.book Page 14 Thursday, March 3, 2005 1:33 PM
Chapter 1: Connecting the Appliance
Inline Deployment Scenarios
Introduction
The Proventia G100, G200, G1000, and G1200 appliances have built-in
copper bypass hardware, which ensures that traffic continues to pass if
the appliance fails or loses power.
Note: The Proventia G1000F and G1200F do not have built-in bypass
hardware. You can purchase an external fiber bypass unit that provides
bypass functionality (contact Internet Security Systems for availability).
See “Connecting the External Bypass Unit” on page 12.
Cabling guidelines
Place a CAT5 crossover cable between a Proventia G appliance and a
server or workstation. ISS recommends using a CAT5 crossover cable
between a Proventia G appliance and a router. A straight cable is
sufficient between a Proventia G appliance and a switch or hub.
Caution: Make sure you verify that traffic is flowing before powering on
the appliance. If cabling is incorrectly installed, the bypass will not
function.
Note: Where a crossover is needed, you may use your own CAT5
crossover cable or the provided one-foot cable and crossover coupler that
ships with the appliance. When the appliance is not running, its
monitoring interfaces function as a crossover. The following scenarios
work independently of the monitoring port (A or B) you use.
Switch/Hub1 to
Switch/Hub2
When you deploy the appliance between two switches or hubs, establish
straight-through connections using CAT 5 cable from Switch1/Hub1 to
the appliance and from the appliance to Switch2/Hub2, as shown
inFigure 6:
Figure 6: Inline deployment scenario, switch/hub to switch/hub
14
GSeries_QuickStartGuide.book Page 15 Thursday, March 3, 2005 1:33 PM
Inline Deployment Scenarios
Workstation/
Server to Router
When you deploy the appliance between a workstation/server and a
router, establish a CAT5 crossover connection from the workstation/
server to the appliance. Establish a crossover CAT 5 connection from the
appliance to the router as shown in Figure 7:
Figure 7: Inline deployment scenario, workstation server to router
Workstation/
Server to Switch/
Hub
When you deploy the appliance between a workstation/server and a
switch/hub, establish a CAT5 crossover connection from the
workstation/server to the appliance. Establish a straight cable connection
from the appliance to the switch/hub as shown in Figure 8:
Figure 8: Inline deployment scenario, workstation server to switch/hub
Router to Switch/
Hub
When you deploy the appliance between a router and a switch/hub,
establish a CAT5 crossover connection from the router to the appliance.
Establish a straight cable connection from the appliance to the switch/
hub as shown in Figure 9:
Figure 9: Inline deployment scenario, router to switch/hub
Proventia G100/G200/G1000/G1200 Quick Start Guide
15
GSeries_QuickStartGuide.book Page 16 Thursday, March 3, 2005 1:33 PM
Chapter 1: Connecting the Appliance
Router to Router
When you deploy the appliance between two routers, establish a CAT5
crossover connections from Router 1 to the appliance and from the
appliance to Router 2, as shown in Figure 10:
Figure 10: Inline deployment scenario, router to router server
16
GSeries_QuickStartGuide.book Page 17 Thursday, March 3, 2005 1:33 PM
Chapter 2
Configuring the Appliance
Overview
Introduction
This chapter describes how to configure Proventia G100/G200/G1000/
G1200 appliances.
In this chapter
This chapter contains the following topics:
Topic
Page
What You Need to Know Before You Start
18
Logging On and Configuring the Appliance
20
Connecting to the Management Console
27
Proventia G100/G200/G1000/G1200 Quick Start Guide
17
GSeries_QuickStartGuide.book Page 18 Thursday, March 3, 2005 1:33 PM
Chapter 2: Configuring the Appliance
What You Need to Know Before You Start
Introduction
This topic provides a checklist of the information that you need prior to
configuring Proventia G Intrusion Prevention Appliances.
Required
information
checklist
Use the following checklist to obtain the information you need to
configure your Proventia G appliance.
9
‰
Setting
Description
Appliance hostname
The unique computer name for your
appliance
Format:
appliance.example.com.
Your setting:
‰
Appliance domain name
The domain suffix for the network
(DNS search path)
Your setting:
‰
Appliance domain name server
This is the IP address of the server
you are using to perform domain
name lookups.
Your setting:
‰
Management Interface IP Address This is the IP address of the
management network adapter.
Your setting:
‰
Management interface subnet
mask
This is the subnet mask value for the
network that will connect to your
management interface.
Your setting:
‰
Management interface default
gateway (IP address)
This is the IP address for the
management gateway.
Your setting:
Table 8: Checklist and worksheet for configuration information
18
GSeries_QuickStartGuide.book Page 19 Thursday, March 3, 2005 1:33 PM
What You Need to Know Before You Start
9
‰
Setting
Description
Operation mode
This is the operation mode to use for
the appliance. The operation mode
you plan to use should correspond to
the way you connected the network
cables.
Your setting:
Table 8: Checklist and worksheet for configuration information (Continued)
Proventia G100/G200/G1000/G1200 Quick Start Guide
19
GSeries_QuickStartGuide.book Page 20 Thursday, March 3, 2005 1:33 PM
Chapter 2: Configuring the Appliance
Logging On and Configuring the Appliance
Introduction
This topic describes how to log on to and configure a Proventia G
Intrusion Prevention Appliance.
Logging on and
changing the
password
To log on to the appliance:
1. Access the Proventia Setup utility (command line interface).
2. At the command login prompt, type admin for the user name, and
then press ENTER.
3. Type admin for the password, and then press ENTER.
The Proventia G Appliance Setup screen appears.
4. Press ENTER.
5. Read the Software License Agreement, and then type Y to accept its
terms.
6. Type the old password admin, and then a new password.
Note: You must use a minimum of six characters.
7. Re-type the new password to confirm it, and then press ENTER.
Note: Record and protect this password. If you lose or forget this
password, you must reinstall the appliance.
8. Press ENTER.
The Network Configuration screen appears.
About configuration
settings
The Proventia G appliance includes settings for processing traffic, as
follows:
●
changing the capture buffer size
●
configuring network congestion options
●
configuring agent options
Important: Network congestion, unresponsive agent, and agent update
options are only used in inline protection modes. These options are not
used in passive mode.
Reference: For more information about these settings, see the Proventia G
Series Appliances User Guide.
20
GSeries_QuickStartGuide.book Page 21 Thursday, March 3, 2005 1:33 PM
Logging On and Configuring the Appliance
Changing the
capture buffer size
The default buffer size for capturing packets is 80 MB. In general, the
capture buffer size does not need to be changed.
Configuring network
congestion options
You can configure how the agent processes traffic when the network is
congested. Options are as follows:
Option
Description
Forward Traffic
This option forwards traffic without processing it, or
fails open to traffic. When traffic levels return to
normal, the agent resumes normal operation.
Drop Traffic
This option blocks some of the traffic without
processing it, or fails closed to traffic. When traffic
levels return to normal, the agent returns to normal
operation.
No Action
This option does not compensate for network
congestion. If the agent cannot process the traffic,
the appliance may go into bypass mode for a short
period on appliance models that have bypass cards
(G100/G200/G1000C). The connection to the
network may be lost for a short period of time on
appliance models that do not have bypass cards
(G1000F).
Table 9: Congestion options
Configuring the
network and host
To configure the network and host:
1. Type the IP Address, Subnet Mask, and Gateway of the appliance’s
management interface, and then press ENTER.
The appliance displays the message:
Network configured
2. Press ENTER.
The Host Configuration screen appears.
3. Type the Hostname (required), Domain Name (recommended), and
Name Server (recommended) for the appliance, and then press
ENTER.
Proventia G100/G200/G1000/G1200 Quick Start Guide
21
GSeries_QuickStartGuide.book Page 22 Thursday, March 3, 2005 1:33 PM
Chapter 2: Configuring the Appliance
Note: The appliance uses domain names and DNS information to
send Email and SNMP responses. If you do not provide this
information now, then you must specify the IP address of the
appliance’s mail server when you define the Email response on the
management console. The appliance must have network access to the
mail server.
The appliance displays a progress message while it configures the
host settings, and then displays the message:
Host configuration has been saved.
4. Press ENTER.
The Timezone Configuration screen appears.
Configuring the
date and time
To configure the date and time at which events occur:
1. Select the continent or ocean in which the appliance is located, and
then press ENTER.
2. Select the country in which the appliance is located, and then press
ENTER.
3. Select the region in which the appliance is located, and then press
ENTER.
Note: This screen does not appear if the country you selected
contains only one time zone.
4. Type y to confirm, and then press ENTER.
The Date/Time Configuration screen appears.
5. Press ENTER to accept the Date and Time for the appliance, or type a
new time and press ENTER.
Note: Use the format [HH:MM:SS] and a 24-hour clock.
The appliance displays the message Date and time set.
6. Press ENTER.
The Agent Name Configuration screen appears.
Configuring agent
options
22
You can configure how the driver processes traffic if an agent becomes
unresponsive or during an agent update. If an agent is not responding,
then it is not monitoring and protecting the network. You can configure
the agent to pass all traffic (fail open to traffic) or drop all traffic (fail
closed to traffic) when it is not responding. Options are as follows:
GSeries_QuickStartGuide.book Page 23 Thursday, March 3, 2005 1:33 PM
Logging On and Configuring the Appliance
Configuring the
agent name
●
maintain link and forward traffic
●
maintain link and drop traffic
●
do not maintain link
To configure the agent name:
1. Press ENTER to accept the default agent name, or type a specific name
and then press ENTER.
Note: This is the asset name that appears for this appliance in your
management interface. ISS recommends that you select a name that
corresponds to the appliance’s geographic location, business unit,
building address, or some other meaningful classification.
The appliance continues to apply your configuration settings. The
status bar displays a message when the configuration ends.
2. Press ENTER.
The Port Link Configuration screen appears.
Setting duplex and
link speed
Proventia G appliance models G100, G200, and G1000 have two ports
labeled A and B. The Proventia G1200 appliance has eight ports labeled A
through H. You can configure link speed and duplex mode settings
appropriate for the appliance you have installed. To improve appliance
performance, choose link speed and duplex mode settings to match your
environment. If you are not sure which settings are correct for your
environment, choose Auto/Auto.
Exception: The default Auto/Auto settings are correct for all
environments except for 100 Full Duplex and 10 Full Duplex. You must
specifically select the duplex mode and link speed applicable for these
environments, as follows:
●
100 Full Duplex–select Full Duplex mode and link speed 100 Mbps
●
10 Full Duplex–select Full Duplex mode and link speed 10 Mbps
Note: For more information, see the Proventia G Appliances User Guide,
“Changing the Link Speed and Duplex Mode Settings.
Proventia G100/G200/G1000/G1200 Quick Start Guide
23
GSeries_QuickStartGuide.book Page 24 Thursday, March 3, 2005 1:33 PM
Chapter 2: Configuring the Appliance
Configuring the link
speed and duplex
mode settings
To configure the link speed and duplex mode settings:
1. Select Port A, and then press the SPACE BAR to select the port link
speed and duplex mode.
2. Select Port B, and then press the SPACE BAR to select the port link
speed and duplex mode.
Note: If you are configuring a Proventia G1200 appliance, repeat
Steps 1 and 2 to select additional ports.
3. Press ENTER.
The Mode Configuration screen appears.
Determining the
operation mode
Determine the operation mode to use with the appliance. There are three
operation modes, as follows:
Operation Mode
Description
Inline Protection
The appliance monitors traffic inline, and blocks
attacks that are configured with the drop response,
dynamic blocking response, and firewall rules.
Inline Simulation
The appliance monitors traffic inline, but does not
block any traffic. Instead, the appliance monitors
traffic and provides passive responses.
Passive Monitoring
The appliance monitors traffic from a tap, hub, or
span port.
Table 10: Operation modes
Configuring the
operation mode
To configure the operation mode:
1. Select an operation mode.
2. Press ENTER.
3. Do one of the following:
24
■
If you selected passive monitoring, the Mode Change
Confirmation screen appears. See “Confirming passive monitoring
mode” on page 25.
■
If you selected inline protection or inline simulation, See
“Applying settings and logging out” on page 26.
GSeries_QuickStartGuide.book Page 25 Thursday, March 3, 2005 1:33 PM
Logging On and Configuring the Appliance
Confirming passive
monitoring mode
To confirm passive monitoring mode:
1. Select passive monitoring from the Mode Change Configuration
screen.
The Mode Change Confirmation screen appears
2. You are asked, “Do you want to confirm passive monitoring mode?”
Configuring the
RSKILL response
■
If yes, type y, and then go to Step 2.
■
If no, type n, and then select a different operation mode, as
described in “Configuring the operation mode.”
To configure the RSKILL response:
1. When you are in the RSKILL response screen, you are asked the
following:
Do you want to configure the RSKill response?
■
If yes, type y, and then go to Step 2.
■
If no, type n, and then Press ENTER.
Note: When the appliance detects an attack, the RSKill response
terminates or resets the connection to the targeted computer.
2. Do you want to use a DHCP server?
■
If yes, press the SPACE BAR to select DHCP.
■
If no, type the static addresses in the IP Address, Subnet Mask,
and Gateway.
Tip: To move from one field to the next, press TAB.
Note: The RSKill response occurs in stealth mode. The appliance
uses these static network addresses to determine the gateway MAC
address. If the appliance cannot determine the MAC address, then
you must manually enter the address on the next screen.
3. Press ENTER.
The appliance attempts to determine and display the gateway MAC
address.
4. Did the appliance determine its MAC address?
■
If yes, press ENTER.
■
If no, type the MAC address.
Proventia G100/G200/G1000/G1200 Quick Start Guide
25
GSeries_QuickStartGuide.book Page 26 Thursday, March 3, 2005 1:33 PM
Chapter 2: Configuring the Appliance
Note: If you do not know the MAC address, contact your system
administrator.
5. Press ENTER.
The appliance continues to apply your configuration settings, and
then displays a message when the configuration is complete.
Applying settings
and logging out
To apply settings and log out:
1. Press ENTER.
The appliance displays a message that it will now log you off. You
can log back in at any time to change configuration settings.
2. Press ENTER.
The login prompt appears.
Note: You may disconnect the monitor and keyboard or the
computer that you just used. You can make all future connections to
the appliance using the ISS management interface. Use SSH to access
the appliance and maintain configuration settings.
26
GSeries_QuickStartGuide.book Page 27 Thursday, March 3, 2005 1:33 PM
Connecting to the Management Console
Connecting to the Management Console
Introduction
This topic explains how to connect to the SiteProtector management
console.
Managing the
appliance from
SiteProtector
After you have installed and configured the appliance, you must
configure additional appliance settings and edit appliance policies from
the SiteProtector management console.
Reference: For instructions on managing the appliance from the
management console, see the SiteProtector documentation at http://
www.iss.net/support/documentation/. Also see the SiteProtector
Help.
Accessing the
SiteProtector Help
To access the SiteProtector Help:
1. On the Console menu bar, select HelpÆ SiteProtector Help.
2. Open the Working with Proventia A and Proventia G Appliances and
Sensors section.
3. Look up “Working with Proventia Appliance Policies” and “Working
with Asset Properties and Responses.”
Licensing
Proventia G appliances require a properly configured license key. If you
have not installed the appropriate license key through the management
console, you will not be able to manage the appliance.
Purchasing a license: To purchase a license for a Proventia G appliance,
contact your local sales representative.
Proventia G100/G200/G1000/G1200 Quick Start Guide
27
GSeries_QuickStartGuide.book Page 28 Thursday, March 3, 2005 1:33 PM
Chapter 2: Configuring the Appliance
28
GSeries_QuickStartGuide.book Page 29 Thursday, March 3, 2005 1:33 PM
Chapter 3
Reinstalling the Appliance
Overview
Introduction
This chapter describes the processes and procedures for reinstalling the
Proventia G100, G200, G1000, or G1200 Intrusion Prevention Appliance.
You must reinstall the appliance software to restore the appliance to its
original configuration and to remove any customized settings.
What you need
To reinstall a Proventia G appliance, you need:
In this chapter
●
a laptop or computer to use as your configuration interface
●
a Proventia G Appliance Recovery CD
This chapter contains the following topics:
Topic
Page
Reinstallation Requirements
30
Reinstalling the Appliance
31
Proventia G100/G200/G1000/G1200 Quick Start Guide
29
GSeries_QuickStartGuide.book Page 30 Thursday, March 3, 2005 1:33 PM
Chapter 3: Reinstalling the Appliance
Reinstallation Requirements
Introduction
You can use the Proventia G Appliance Recovery CD to reinstall the
appliance. The CD reinstalls the original, unconfigured software. To
reinstall the software, you must complete the following procedures:
●
reinstall the appliance
●
log in and change the password
●
configure the network and host
●
configure the date and time
●
configure the agent name
●
configure the link speed and duplex mode settings
●
configure the operation mode
●
confirm passive monitoring mode
●
configuring the RSKILL response
●
apply settings and log out
Note: After rebooting with the recovery CD, the appliance reverts to the
default login name and password.
Prerequisites
30
Before you reconfigure the appliance, you must have completed the
following prerequisites:
●
Verify the IP address, subnet mask, and default gateway of the
appliance’s management interface.
●
Verify the hostname (required), domain name (recommended), and
DNS name server (recommended) for the appliance.
●
Verify that the appliance is operational. If your appliance is not
operational, contact ISS Customer Support at support@iss.net.
GSeries_QuickStartGuide.book Page 31 Thursday, March 3, 2005 1:33 PM
Reinstalling the Appliance
Reinstalling the Appliance
Reinstalling the
appliance
To reinstall the appliance:
1. If there is a bezel cover on the front of the appliance, remove it.
2. Place the Proventia G Appliance Recovery CD in the CD-ROM drive.
3. Connect a computer or monitor and keyboard to the appliance.
Reference: For more information, see “Setting up terminal
emulation” on page 11.
4. Reboot the appliance.
Tip: You can manually turn the power off and on if the appliance is
not responding.
The appliance reboots and reloads the operating system.
5. Type reinstall, and then press ENTER.
The appliance displays status messages, ejects the CD, and then
reboots.
Logging on and
changing the
password
To log on and change the password:
1. When the appliance has rebooted, type admin at the unconfigured
login prompt, and then press ENTER.
2. Type admin at the Password prompt, and then press ENTER.
The Proventia G Setup screen appears.
3. Press ENTER.
The Software License Agreement appears.
4. Read the Software License Agreement, and then type y to accept its
terms.
The Change Password screen appears.
5. Type the old password, admin, and then type a new password.
Note: You must use a minimum of six characters.
6. Retype the new password to confirm it, and then press ENTER.
Note: Record and protect this password. If you lose or forget this
password, you must reinstall the appliance.
Proventia G100/G200/G1000/G1200 Quick Start Guide
31
GSeries_QuickStartGuide.book Page 32 Thursday, March 3, 2005 1:33 PM
Chapter 3: Reinstalling the Appliance
7. Press ENTER.
The Network Configuration screen appears.
Configuring the
network and host
To configure the network and host:
1. Type the IP Address, Subnet Mask, and Gateway of the appliance’s
management interface, and then press ENTER.
The appliance displays the message:
Network configured.
2. Press ENTER.
The Host Configuration screen appears.
3. Type the Hostname (required), Domain Name (recommended), and
Name Server (recommended) for the appliance, and then press
ENTER.
Note: The appliance uses domain names and DNS information to
send Email and SNMP responses. If you do not provide this
information now, then you must specify the IP address of the
appliance’s mail server when you define the Email response on the
management console. The appliance must have network access to the
mail server. For more information, see the management console's user
documentation.
The appliance displays a progress message while it configures the
host settings, and then displays the message Host configuration
has been saved when the configuration is complete.
4. Press ENTER.
The Timezone Configuration screen appears.
Configuring the
date and time
To configure the date and time at which events occur:
1. Select the continent or ocean in which the appliance is located, and
then press ENTER.
2. Select the country in which the appliance is located, and then press
ENTER.
3. Select the region in which the appliance is located, and then press
ENTER.
32
GSeries_QuickStartGuide.book Page 33 Thursday, March 3, 2005 1:33 PM
Reinstalling the Appliance
Note: This screen does not appear if the country you selected
contains only one time zone.
4. Type y to confirm, and then press ENTER.
The Date/Time Configuration screen appears.
5. Press ENTER to accept the Date and Time for the appliance, or type a
new time and press ENTER.
Note: Use the format [HH:MM:SS] and a 24-hour clock.
The appliance displays the message Date and time set.
6. Press ENTER.
The Agent Name Configuration screen appears.
7. Go to “Configuring the agent name,” next in this topic.
Configuring the
agent name
To configure the agent name:
1. Press ENTER to accept the default agent name, or type a specific name
and then press ENTER.
Note: This is the asset name that appears for this appliance in your
management interface. ISS recommends that you select a name that
corresponds to the appliance’s geographic location, business unit,
building address, or some other meaningful classification.
The appliance continues to apply your configuration settings. The
status bar displays a message when the configuration ends.
2. Press ENTER.
The Port Link Configuration screen appears.
Proventia G100/G200/G1000/G1200 Quick Start Guide
33
GSeries_QuickStartGuide.book Page 34 Thursday, March 3, 2005 1:33 PM
Chapter 3: Reinstalling the Appliance
Configuring the link
speed and duplex
mode settings
Proventia G appliance models G100, G200, and G1000 have two ports
labeled A and B. The Proventia G1200 appliance has eight ports labeled A
through H. You can configure link speed and duplex mode settings
appropriate for the appliance you have installed.
To configure the link speed and duplex mode settings:
1. Select Port A, and then press the SPACE BAR to select the port link
speed and duplex mode.
2. Select Port B, and then press the SPACE BAR to select the port link
speed and duplex mode.
Note: If you are configuring a Proventia G1200 appliance, repeat
Steps 1 and 2 to select additional ports.
3. Press ENTER.
The Mode Configuration screen appears.
Configuring the
operation mode
To configure the operation mode:
1. Select an operation mode.
2. Press ENTER.
3. Do one of the following:
Confirming passive
monitoring mode
■
If you selected passive monitoring, the Mode Change
Confirmation screen appears. Go to “Confirming passive
monitoring mode.”
■
If you selected inline protection or inline simulation, see
“Applying settings and logging out” on page 36.
To confirm passive monitoring mode:
1. Do you want to confirm passive monitoring mode?
■
If yes, type y, and then go to Step 2.
■
If no, type n, and then select a different operation mode, as
described in “Configuring the operation mode.”
2. Press ENTER, and then go to “Configuring the RSKILL response” on
page 35.
34
GSeries_QuickStartGuide.book Page 35 Thursday, March 3, 2005 1:33 PM
Reinstalling the Appliance
Configuring the
RSKILL response
To configure the RSKILL response:
1. Do you want to configure the RSKill response?
■
If yes, type y, and then go to Step 2.
■
If no, type n, and then go to Step 1 in “Applying settings and
logging out,” next in this topic.
Note: When the appliance detects an attack, the RSKill response
terminates or resets the connection to the targeted computer.
2. Do you want to use a DHCP server?
■
If yes, press the SPACE BAR to select DHCP.
■
If no, type the static addresses in the IP Address, Subnet Mask,
and Gateway.
Tip: To move from one field to the next, press TAB.
Note: The RSKill response occurs in stealth mode. The appliance
uses these static network addresses to determine the gateway MAC
address. If the appliance cannot determine the MAC address, then
you must manually enter the address on the next screen.
3. Press ENTER.
The appliance attempts to determine and display the gateway MAC
address.
4. Did the appliance determine its MAC address?
■
If yes, press ENTER.
■
If no, type the MAC address.
Note: If you do not know the MAC address, contact your system
administrator.
5. Press ENTER.
The appliance continues to apply your configuration settings, and
then displays a message when the configuration is complete.
Proventia G100/G200/G1000/G1200 Quick Start Guide
35
GSeries_QuickStartGuide.book Page 36 Thursday, March 3, 2005 1:33 PM
Chapter 3: Reinstalling the Appliance
Applying settings
and logging out
To apply settings and log out:
1. Press ENTER.
The appliance displays a message that it will now log you off. You
can log back in at any time to change configuration settings.
2. Press ENTER.
The login prompt appears.
36
GSeries_QuickStartGuide.book Page 37 Thursday, March 3, 2005 1:33 PM
Getting Technical Support
Getting Technical Support
Introduction
ISS provides technical support through its Web site and by email or
telephone.
The ISS Web site
The Internet Security Systems (ISS) Resource Center Web site (http://
www.iss.net/support/) provides direct access to frequently asked
questions (FAQs), white papers, online user documentation, current
versions listings, detailed product literature, and the Technical Support
Knowledgebase (http://www.iss.net/support/knowledgebase/).
Support levels
ISS offers three levels of support:
●
Standard
●
Select
●
Premium
Each level provides you with 24-7 telephone and electronic support.
Select and Premium services provide more features and benefits than the
Standard service. Contact Client Services at clientservices@iss.net if
you do not know the level of support your organization has selected.
Hours of support
The following table provides hours for Technical Support at the Americas
and other locations:
Location
Hours
Americas
24 hours a day
All other
locations
Monday through Friday, 9:00 A.M. to 6:00 P.M. during their
local time, excluding ISS published holidays
Note: If your local support office is located outside the
Americas, you may call or send an email to the Americas
office for help during off-hours.
Table 11: Hours for technical support
Proventia G100/G200/G1000/G1200 Quick Start Guide
37
GSeries_QuickStartGuide.book Page 38 Thursday, March 3, 2005 1:33 PM
Chapter 3: Reinstalling the Appliance
Contact information
The following table provides electronic support information and
telephone numbers for technical support requests:
Regional
Office
Electronic Support
Telephone Number
North America
Connect to the MYISS
section of our Web site:
Standard:
www.iss.net
(1) (888) 447-4861 (toll free)
(1) (404) 236-2700
Select and Premium:
Refer to your Welcome Kit or
call your Primary Designated
Contact for this information.
Latin America
support@iss.net
(1) (888) 447-4861 (toll free)
(1) (404) 236-2700
Europe, Middle support@iss.net
East, and Africa
Asia-Pacific,
Australia, and
the Philippines
support@iss.net
Japan
support@isskk.co.jp
(44) (1753) 845105
(1) (888) 447-4861 (toll free)
(1) (404) 236-2700
Domestic: (81) (3) 5740-4065
Table 12: Contact information for technical support
38
GSeries_QuickStartGuide.book Page 39 Thursday, March 3, 2005 1:33 PM
Index
a
d
AC power 6
agent name 23, 33
appliance
logging out 26, 36
appliance packaging 2
DC power 6
DHCP server 25, 35
domain names 22, 32
e
b
buffer size
email responses
21
f
c
cabling guidelines 14
changing
appliance modes 25, 34
passwords 31
checklist 18
configuration
checklist 18
configuring
agent name 23, 33
link speed and duplex mode settings
network and host 32
operation mode 24, 34
confirming
passive monitoring mode 25, 34
conventions, typographical
in commands ix
in procedures viii
in this manual viii
22, 32
front panel
3
g
gateway MAC address
25, 35
i
24, 34
Internet Security Systems
technical support 37
Web site 37
l
license key
installing 27
purchasing 27
Proventia G100/G200/G1000/G1200 Quick Start Guide
39
GSeries_QuickStartGuide.book Page 40 Thursday, March 3, 2005 1:33 PM
Index
m
s
MAC address 25, 35
management console 27
user documentation 27
managing the appliance 27
mid-mount rack kit 2
SiteProtector
Help 27
sliding rail kit 2
SNMP responses 22, 32
stealth mode 25, 35
o
t
online Help
for SiteProtector 27
operation modes 24
technical support, Internet Security
Systems 37
terminal emulation program 6
typographical conventions viii–ix
p
passive monitoring mode
confirming 25, 34
passwords
changing 31
minimum requirements 31
Proventia G Appliance Recovery CD
w
Web site, Internet Security Systems
30
r
reinstalling the appliance 29, 32
applying settings and logging out 26, 36
configuring
date and time 22, 32
configuring the agent name and RSKILL
response 23, 33
configuring the network and host 32
logging in and changing the password 31
required procedures 30
RSKILL response 25, 30, 35
40
37
Was this manual useful for you? yes no