Choose the Fluke Ti5x models when you need the best images.

They feature 320 x 240 detectors with industry leading thermal sensitivity ( ≤ 0.07 °C NETD) for high resolution, ultra highquality images. In addition, with a 60 Hz detector acquisition rate temperatures are displayed live on the large 5-inch color display.

Features

High resolution, low noise VOx detector for high quality images

Temperature range to cover broad industrial applications

High thermal sensitivity for viewing even the smallest temperature differences

180° articulating flexible lens to view images in every situation

Choice of 3 interchangeable lenses to cover every application

Large 5” high contrast color LCD for a clear picture independent of lighting conditions

Fully radiometric for detailed temperature analysis and tracking

SmartFocus for best image quality and accurate temperature measurements

Windows ® CE based menu structure for ease of use

Personalized instrument set-up for multiple use

CompactFlash memory cards to store over 1000 IR images plus fully radiometric temperature data

SmartView reporting and analysis software included

AutoCapture for making intermittent problems visible

On-board analysis functions

User defined text annotations for simplified reporting

Built-in visible light (digital) camera

IR-Fusion blending thermal and visible light images to easily pinpoint suspect components

IR/Visible Alarm function

Laser pointer for easy targeting

Flash and torch light for high quality images in dark environments

Ti55FT Ti55 Ti50FT Ti50

320 x 240

-20 to +600 o C (-4 ºF to 1112 ºF) -20 to +350 o C (-4 ºF to 662 ºF)

≤0.07 o C

● ● ● ●

Typical applications

• Predictive maintenance – Identify electrical and mechanical problems before they cause failure

• Power/utilities – Real-time analysis of substations, transmission lines and equipment

• Process monitoring – Real-time observation to ensure efficient and safe operation

• Research and development – Quantify heat patterns to improve product designs

• Electronic design – Close up circuit board analysis

Printed circuit board

Power/utilities

Electrical system

ENEN

Back to the Fluke Ti50/55 Product Info Page

Visit us at www.TestEquipmentDepot.com

Specifications

Imaging performance

Temperature measurement

Image presentation

Optional lenses

Image and data storage

Interfaces and software

Laser (IR-Fusion models only)

Controls and adjustments

Power

Thermal

Field of view (FOV)*

Spatial resolution (IFOV)*

Min focus distance*

Thermal sensitivity (NETD)

Detector data acquisition /

Image frequency

Focus

IR digital zoom

Detector type

Spectral band

Digital image enhancement

Visual (IR-Fusion models only)

On camera operating modes

Visible light camera

Visible light digital zoom

Fluke Ti55

23° horizontal x 17° vertical

1.30 mrad

0.15 m

≤0.07 °C at 30 °C

60 Hz/30 Hz

Fluke Ti50

SmartFocus; one finger continuous focus

2x, 4x, 8x 2x

320 x 240 Focal Plane Array, Vanadium Oxide (VOx) Uncooled Microbolometer with 25 micron pitch

8 μm to 14 μm

Automatic full-time enhanced

Full thermal, full visual light or merged thermal-visual images.

Picture-in-Picture

1280 x 1024 pixels, full color

2x, 4x, 8x 2x

Calibrated temperature range -20 °C to 600 °C (-4 ºF to 1112 ºF) in 3 ranges -20 °C to 350 °C (-4 ºF to 662 ºF) in 2 ranges

Range 1 = -20 °C to 100 °C (-4 ºF to 212 ºF) Range 1 = -20 °C to 100 °C (-4 ºF to 212 ºF)

Range 2 = -20 °C to 350 °C (32 ºF to 662 ºF) Range 2 = -20 °C to 350 °C (32 ºF to 662 ºF)

Range 3 = 250 °C to 600 °C (482 ºF to 1112 ºF) -

Accuracy

Measurement modes

Emissivity correction

Centerpoint, center box (area min/max, average), moveable spots/boxes, user defined field/text annotations, isotherms, automatic hot and cold point detection, visible color alarm above and below

±2 °C or 2% (whichever is greater)

Centerpoint, center box

(area min/max, average)

0.1 to 1.0 (0.01 increments)

Digital display

LCD backlight

Video output

Palettes

54 mm Telephoto lens

Field of view (FOV)

Spatial resolution (IFOV)

Min focus distance

10.5 mm wide angle lens

Field of view (FOV

Spatial resolution (IFOV)

Min focus distance

5” large high-resolution digital display

Sunlight readable color LCD

RS170 EIA/NTSC or CCIR/PAL composite video

Grayscale, grayscale inverted, blue red, high contrast, hot metal, ironbow, amber, amber inverted

High precision Germanium lens

9° horizontal x 6° vertical

0.47 mrad

0.6 m

High precision Germanium lens

42° horizontal x 32° vertical

2.45 mrad

0.3 m

Storage medium

File formats supported

Interface

Software

Classification

Laser targeting

Set-up controls

Image controls

On-screen indicators

Battery type

Battery operating time

Battery charging

AC operation

Power saving

Operating temperature

Storage temperature

Relative humidity

Water and dust resistant

Weight (including batteries)

Camera size (HxWxD)

Warranty

Compact flash card stores over 1000 IR images (512 MB card standard)

14 bit measurement data included. Exportable JPEG, BMP, PCX, PNG, PSD.

Compact flash card reader included

SmartView; Full analysis and reporting software included

Class II

Laser dot visible on screen when blending thermal and visible image

Date/time, temperature units C/F, language, scale, LCD intensity (high/normal/low)

Level, span, auto adjust (continuous/manual)

Battery status, target emissivity, background temperature and realtime clock

Li-Ion smart battery, rechargeable, field-replaceable

3 hours continuous operation (2 hours for models with IR-Fusion)

2 bay intelligent charger powered via AC outlet

AC adapter 110/220 VAC, 50/60 Hz -

Automatic shutdown and sleep modes (user specified)

-10 °C to +50 °C (14 ºF to 122 ºF)

-40 °C to +70 °C (-40 ºF to 158 ºF)

Operating and storage 10% to 95%, non-condensing

IP54

1.95 kg (4.3 lb)

162 x 262 x 101 mm (6.6 in x 10.5 in x 4.0 in)

2 years

Environmental and mechanical design

Other

*standard 20 mm Germanium lens

Included accessories

Heavy duty carrying case

2 rechargeable battery packs

Battery charger

AC adapter (for Ti55 model only)

Video cable

512 MB compact flash card

Compact flash card reader and USB cable

PCMCIA compact flash card reader

Neck strap

SmartView reporting and analysis software on CD

User manual on CD

Ordering information*

Fluke Ti50-20 IR FlexCam Thermal

Imager

Fluke Ti50FT-20 IR FlexCam Thermal

Imager with IR-Fusion

Fluke Ti55-20 IR FlexCam Thermal

Imager

Fluke Ti55FT-20 IR FlexCam Thermal

Imager with IR-Fusion

*For ordering information of optional lenses check the Fluke web

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176

FAX 781.665.0780 - TestEquipmentDepot.com

ENEN

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement