- No category
advertisement
99 Washington Street
Melrose, MA 02176
Fax 781-665-0780
TestEquipmentDepot.com
Visit us at www.TestEquipmentDepot.com
Ti50 and Ti55 IR FlexCam
®
Thermal Imagers
The professional’s choice when demanding the highest sensitivity
Choose the Fluke Ti5x models when you need the best images.
They feature 320 x 240 detectors with industry leading thermal sensitivity ( ≤ 0.07 °C NETD) for high resolution, ultra highquality images. In addition, with a 60 Hz detector acquisition rate temperatures are displayed live on the large 5-inch color display.
Features
High resolution, low noise VOx detector for high quality images
Temperature range to cover broad industrial applications
High thermal sensitivity for viewing even the smallest temperature differences
180° articulating flexible lens to view images in every situation
Choice of 3 interchangeable lenses to cover every application
Large 5” high contrast color LCD for a clear picture independent of lighting conditions
Fully radiometric for detailed temperature analysis and tracking
SmartFocus for best image quality and accurate temperature measurements
Windows ® CE based menu structure for ease of use
Personalized instrument set-up for multiple use
CompactFlash memory cards to store over 1000 IR images plus fully radiometric temperature data
SmartView reporting and analysis software included
AutoCapture for making intermittent problems visible
On-board analysis functions
User defined text annotations for simplified reporting
Built-in visible light (digital) camera
IR-Fusion blending thermal and visible light images to easily pinpoint suspect components
IR/Visible Alarm function
Laser pointer for easy targeting
Flash and torch light for high quality images in dark environments
●
●
●
●
●
●
●
●
●
Ti55FT Ti55 Ti50FT Ti50
320 x 240
-20 to +600 o C (-4 ºF to 1112 ºF) -20 to +350 o C (-4 ºF to 662 ºF)
≤0.07 o C
● ● ● ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Typical applications
• Predictive maintenance – Identify electrical and mechanical problems before they cause failure
• Power/utilities – Real-time analysis of substations, transmission lines and equipment
• Process monitoring – Real-time observation to ensure efficient and safe operation
• Research and development – Quantify heat patterns to improve product designs
• Electronic design – Close up circuit board analysis
Printed circuit board
Power/utilities
Electrical system
ENEN
Back to the Fluke Ti50/55 Product Info Page
Visit us at www.TestEquipmentDepot.com
Specifications
Imaging performance
Temperature measurement
Image presentation
Optional lenses
Image and data storage
Interfaces and software
Laser (IR-Fusion models only)
Controls and adjustments
Power
Thermal
Field of view (FOV)*
Spatial resolution (IFOV)*
Min focus distance*
Thermal sensitivity (NETD)
Detector data acquisition /
Image frequency
Focus
IR digital zoom
Detector type
Spectral band
Digital image enhancement
Visual (IR-Fusion models only)
On camera operating modes
Visible light camera
Visible light digital zoom
Fluke Ti55
23° horizontal x 17° vertical
1.30 mrad
0.15 m
≤0.07 °C at 30 °C
60 Hz/30 Hz
Fluke Ti50
SmartFocus; one finger continuous focus
2x, 4x, 8x 2x
320 x 240 Focal Plane Array, Vanadium Oxide (VOx) Uncooled Microbolometer with 25 micron pitch
8 μm to 14 μm
Automatic full-time enhanced
Full thermal, full visual light or merged thermal-visual images.
Picture-in-Picture
1280 x 1024 pixels, full color
2x, 4x, 8x 2x
Calibrated temperature range -20 °C to 600 °C (-4 ºF to 1112 ºF) in 3 ranges -20 °C to 350 °C (-4 ºF to 662 ºF) in 2 ranges
Range 1 = -20 °C to 100 °C (-4 ºF to 212 ºF) Range 1 = -20 °C to 100 °C (-4 ºF to 212 ºF)
Range 2 = -20 °C to 350 °C (32 ºF to 662 ºF) Range 2 = -20 °C to 350 °C (32 ºF to 662 ºF)
Range 3 = 250 °C to 600 °C (482 ºF to 1112 ºF) -
Accuracy
Measurement modes
Emissivity correction
Centerpoint, center box (area min/max, average), moveable spots/boxes, user defined field/text annotations, isotherms, automatic hot and cold point detection, visible color alarm above and below
±2 °C or 2% (whichever is greater)
Centerpoint, center box
(area min/max, average)
0.1 to 1.0 (0.01 increments)
Digital display
LCD backlight
Video output
Palettes
54 mm Telephoto lens
Field of view (FOV)
Spatial resolution (IFOV)
Min focus distance
10.5 mm wide angle lens
Field of view (FOV
Spatial resolution (IFOV)
Min focus distance
5” large high-resolution digital display
Sunlight readable color LCD
RS170 EIA/NTSC or CCIR/PAL composite video
Grayscale, grayscale inverted, blue red, high contrast, hot metal, ironbow, amber, amber inverted
High precision Germanium lens
9° horizontal x 6° vertical
0.47 mrad
0.6 m
High precision Germanium lens
42° horizontal x 32° vertical
2.45 mrad
0.3 m
Storage medium
File formats supported
Interface
Software
Classification
Laser targeting
Set-up controls
Image controls
On-screen indicators
Battery type
Battery operating time
Battery charging
AC operation
Power saving
Operating temperature
Storage temperature
Relative humidity
Water and dust resistant
Weight (including batteries)
Camera size (HxWxD)
Warranty
Compact flash card stores over 1000 IR images (512 MB card standard)
14 bit measurement data included. Exportable JPEG, BMP, PCX, PNG, PSD.
Compact flash card reader included
SmartView; Full analysis and reporting software included
Class II
Laser dot visible on screen when blending thermal and visible image
Date/time, temperature units C/F, language, scale, LCD intensity (high/normal/low)
Level, span, auto adjust (continuous/manual)
Battery status, target emissivity, background temperature and realtime clock
Li-Ion smart battery, rechargeable, field-replaceable
3 hours continuous operation (2 hours for models with IR-Fusion)
2 bay intelligent charger powered via AC outlet
AC adapter 110/220 VAC, 50/60 Hz -
Automatic shutdown and sleep modes (user specified)
-10 °C to +50 °C (14 ºF to 122 ºF)
-40 °C to +70 °C (-40 ºF to 158 ºF)
Operating and storage 10% to 95%, non-condensing
IP54
1.95 kg (4.3 lb)
162 x 262 x 101 mm (6.6 in x 10.5 in x 4.0 in)
2 years
Environmental and mechanical design
Other
*standard 20 mm Germanium lens
Included accessories
Heavy duty carrying case
2 rechargeable battery packs
Battery charger
AC adapter (for Ti55 model only)
Video cable
512 MB compact flash card
Compact flash card reader and USB cable
PCMCIA compact flash card reader
Neck strap
SmartView reporting and analysis software on CD
User manual on CD
Ordering information*
Fluke Ti50-20 IR FlexCam Thermal
Imager
Fluke Ti50FT-20 IR FlexCam Thermal
Imager with IR-Fusion
Fluke Ti55-20 IR FlexCam Thermal
Imager
Fluke Ti55FT-20 IR FlexCam Thermal
Imager with IR-Fusion
*For ordering information of optional lenses check the Fluke web
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
FAX 781.665.0780 - TestEquipmentDepot.com
ENEN
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project