Using Your acaia Coffee Scale
Identification
The instructions in this operation manual apply to the acaia | lunar. You have purchased a quality
precision weighing scale that requires handling with care. Make sure to read through this operation
manual prior to using the scale.
CAUTION:
1. Any modification made without the consent of the manufacturer will result in the
warranty being voided.
2. Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries
according to the instructions.
Contents
4
Chapter 1: Scale at a Glance
4
4
5
6
6
7
7
Introduction
Specification
Scale Overview
Accessories
Buttons
LED Indicators
Battery Charge
8
Chapter 2: Getting Started
8
9
Preparation
Charging and Setup
10
Chapter 3: Basics
10
11
12
12
13
An Overview of Operation Structure
Basic Operations
Weighing Mode
Dual Display Mode
Auto Start Modes
19
Chapter 4: Configuration
19
20
21
21
21
22
22
22
23
23
23
23
24
24
24
24
Operations for Setup Mode
Diagram of Setup Mode Settings
Auto Switch Off Setting
Zero Tracking Setting
Key Sound Setting
Zero Range Setting
Weighing Filter Setting
Default Unit Setting
Weighing Resolution Setting
Weighting Mode Setting
Dual Display Mode Setting
Auto Start Mode
Setting
Auto Start Mode
Setting
Auto Start Mode
Setting
Reset Password Setting
Bluetooth Setup Setting
25
Appendix A. Smart-Calibration
25
Calibration Mode
26
Appendix B. Display Codes
26
26
Error Code List
Others
Chapter 1: Scale at a Glance
Introduction
3. Thank you for choosing one of our scales. The acaia | lunar is designed and manufactured to
the most rigorous standard to give you the best coffee brewing experience. Start by checking
that your acaia | lunar box contains all the parts listed below:
" acaia | lunar
" Micro USB cable
" acaia Scale Weight 100g " Heat Resistant Pad
4. Next, follow the instructions in the Preparation and Installation sections in the manual to get
started.
5. To take an advantage of its many features, carefully read through the operation manual
containing step-by-step procedures, examples, and other information.
6. Warning: Incorrect handling of this product could possibly result in personal injury or
physical damage.
Specifications
Aprox. weight
270g
Capacity
2000g / 70.54oz
Measuring Units
g , oz
Weighing range
Maximum capacity
2000.0g
70.540oz
Division
0.1g
0.002 oz
Reference division
0.01g
0.0005 oz
Indication limit
2060.00g / 72.6600oz
Unit dimensions
105mm(W) x 105mm (L) x 15.5mm (H) Electrical Requirements
5V/500mA
Power and Battery
Lithium-ion rechargeable 3.7V 1100mA
Display
8 digit LED
Top
Aluminum construction with acrylic
window, touch sensitive buttons Bottom
Aluminum construction
Connectivity
Bluetooth 4.0
Linearity
+/- 0.2g
Chapter 1: Scale at a Glance
4
Scale Overview
Weighing Pan
Power Key
Scale Front
LED Display
Tare Key
Micro-B USB port
Scale Back
Chapter 1: Scale at a Glance
5
Accessories
Micro USB
Charging Cable
acaia Scale Weight
100G
Micro-B
Type A
Buttons
*Please see Chapter 3: Basics for more details.
Chapter 1: Scale at a Glance
6
LED Indicators
Battery Charge
You can charge the battery by plugging the USB cable to any power supply listed below:
A computer USB port
A cell phone charger with a micro USB connector
An automotive cell phone charger with a USB port or a Micro USB cable
It takes 1-2 hours to fully charge the battery. You can charge the battery more frequently so
that it will never run out of charge.
Battery percentage can be viewed in acaia Apps.
It is not recommended to let the battery run out completely before charge.
Chapter 1: Scale at a Glance
7
Chapter 2: Getting Started
Preparation
This scale is intended for indoor use.
Select a work place that is stable, vibration-free and, if possible, a horizontal location for the
weighing platform.
Do not locate the scale near any equipment/instrument which contains magnets.
Avoid places where room temperatures are unstable. Room temperature above 40℃ or below
15℃ may result in weighing inaccuracy.
Chapter 1: Scale at a Glance
8
Charging and Setup
To use AC adapter instead of the built-in battery, plug the USB cable into the Micro-B USB port
located on the back panel of the scale.
Press
button for 0.5 seconds to turn on the scale.
Chapter 1: Scale at a Glance
9
Chapter 3: Basics
An Overview of Operation Structure
Chapter 3: Basics
10
Basic Operations
Turn On
• Press and hold
button for 0.5 seconds to turn on the scale.
Turn Off
• Double click
button to turn off the scale.
Switch Modes
• Press and hold
button for 1 second each time to toggle through different modes.
Chapter 3: Basics
11
Weighing Mode
Display
There are two different weighing units in Weighing Mode: grams and ounces. It can be identified if
the upper right LED is light on. If the LED is light on, the weighing unit is ounce.
The readability is 0.1g or 0.002oz base on the weighing unit selected in Setup Mode.
For high resolution mode, the readability is 0.01g or 0.0005oz.
Note: To change default weighing unit, please see Chapter 4 Default Unit Setting for more
information.
Operation
1. Press
button for tare (zero) operation.
2. Press and hold
button for 1 second to switch to Dual Display Mode.
Dual Display Mode
Display
The LED display shows [ 0: 00 0.0] with timer on the left and the weight value on the right.
Operation
1. Press
2. Press
button to start/pause/reset the timer.
button to tare the weight.
3. Press and hold
button for 1 second to switch to Auto Start Mode (
)
Note
1. The maximum time that can be displayed is 9 minutes and 59 seconds.
2. When the limit is reached, the timer still goes up until 999 minutes and 59 seconds. It can be
observed by iOS/Android App.
Chapter 3: Basics
12
Auto Start Modes
Display
1. The LED display shows [0: 00 0.0] with timer on the left and the weight value on the right.
2. The timer displays from [0:00] to [9:59] and then the timer will stop.
Status Icon
The icon indicator LED on the right side, if the status icon lights on, the scale is under Auto Start
Mode.
1. Droplet
: When the scale detects the water flow, the timer starts. The timer will stop when the
water flow stops.
2. Triangle
: The scale performs auto-tare operation when placing stable weight on the Lunar,
then starts the timer
3. Square
: When placing stable weight on the scale, the scale will perform auto-tare operation.
Chapter 3: Basics
13
Mode Description
1. Droplet
• The scale detects the espresso flow, then the timer starts.
• When the espresso flow stops with the timer running, the timer stops.
Chapter 3: Basics
14
2. Droplet and Square
This mode is designed for baristas who would like to measure the time of the shot starting from the
first few drops of espresso in a busy environment.
• When placing a stable weight on the scale, the scale will perform auto-tare operation.
• After the scale detects the espresso flow, the timer starts. The timer will stop when the
espresso flow stops.
Chapter 3: Basics
15
3. Triangle and Square
In this mode, the barista would like to measure the total time of a shot including the pre-infusion
time. After placing a stable weight such as a cup on the scale, it performs auto-tare operation, then
the timer starts.
Chapter 3: Basics
16
Note:
1. In all Auto Start Modes, the timer will stop when the espresso flow stops.
2. In all Auto Start Modes, if you do not operate the scale for 30 seconds, it will reset timer and
perform tare operation.
3. In all Auto Start Modes, the timer will stop when a negative weight (i.e. removal of cup) is
detected.
4. The scale will also display a previous stable weight that captures the coffee weight of the shot
when you unloaded the cup.
Chapter 3: Basics
17
Operation
1. Press
button to start/pause/reset the timer.
2. Press
button for tare (zero) operation.
3. Press
button twice to reset timer and tare weight.
4. Press and hold
button for 1 second to switch to Auto Start Modes. If the Triangle and
Square icon indicator are light on, press and
button for 1 second will switch to Weighing
Mode.
Chapter 3: Basics
18
Chapter 4: Configuration
Operations for Setup Mode
Steps to enter Setup Mode
1. Press and hold
button while turning ON the scale. When the LED display shows
[ :ACAIA ]and then [ SEt ] , press and hold
button. Release both
and
button for another 1 second without releasing
buttons when the display shows [ F.0000 ] with the very
left 0 flashing.
2. Press and hold
button for 1 second to move the flashing digit to the right. Repeat this step for
3 times.
3. Press and hold
button for 1 second to confirm the password, and to enter the first setting in
Setup Mode: the LED display shows [ SLEEP ].
Key Operations in Setup Mode
1. Press
button to toggle through setting menu or the options under each setting.
2. Press and hold
3. Press
button to enter each setting or to confirm the selected option.
button to save changes and return Weighing Mode from setting menu.
Chapter 4: Configuration
19
Diagram of Setup Mode Settings
Chapter 4: Configuration
20
Auto Switch Off Setting [ SLEEP ]
1. Auto Switch Off Settings can also be configured in the acaia Apps.
2. The number indicates the amount of time before the scale enters sleeping mode. For example,
when 10 is selected, the scale enters sleeping mode after 10 minutes being idle, while the scale
is disconnected from all mobile devices and no operation has been performed on the scale.
3. Press
button to toggle through the options.
4. Press and hold
button for 1 second until the next setting, [ trAcE ], is shown on LED to
confirm the selected option.
Zero Tracking Setting [ trAcE ]
1. Zero Tracking is a function for maintaining the zero indication within certain limits automatically.
2. OFF: It is not recommended to turn off the Zero Tracking because the zero indication would
draft easily as room temperature changes.
3. 0.5d~3d: For example, for standard resolution each division is 0.1g, 3d = 0.3g. When Zero
Tracking is set to be 3d, any initial weight between +/- 0.3g on the weighing pan would be
zeroed out gradually.
4. 2d is recommended in general for acaia | lunar.
5. Press and hold
button for 1 second until the next setting, [ bEEP ], is shown on LED to
confirm the selected option.
Key Sound Setting [ bEEP ]
1. Key Sound Settings can also be configured in the acaia Apps
2. Set the Key Sound function off to turn off the beeping sound or on to turn on the beeping sound.
3. Press and hold
button for 1 second until the next setting, [ 0.rAnGE ], is shown on LED to
confirm the selected option.
Chapter 4: Configuration
21
Zero Range Setting [ 0.rAnGE ]
1. Zero Range setting determines the range for which
button executes zero operation instead
of tare operation.
2. When Zero Range is set to 2, the range for zero-setting will be 2% of the capacity, i.e., +/- 40g
for acaia | lunar. By pressing
button, any weight within +/- 40g is zeroed out by zero
operation while any weight lays outside the range is tared out by tare operation.
3. If Zero Range is set to 100, the range for zero-setting will be 100% of the capacity, i.e., +/- 2kg
for acaia | lunar. Therefore, instead of tare operation, zero operation would be executed in this
setting whenever
4. Press and hold
button is pressed.
button for 1 second until the next setting, [ Filt. ], is shown on LED to
confirm the selected option.
5. Notice: The difference between zero operation and tare operation is that zero operation would
simply ignore the weight and display as 0 while tare operation would deduct the weight from
weighing result. However, zero operation does not increase the scale capacity.
Weighing Filter Setting [ Filt. ]
1. The number shown on LED display indicates the current filter parameter which determines the
speed for load receptor to response to weight and to determine the weighing value. The larger
the number, the more stable but slower the weighing result will be.
2. Press
button to change the parameter.
3. Press and hold
button for 1 second until the next setting, [ Unit ] is shown on the LED to
confirm the selected parameter.
Default Unit Setting [ Unit ]
1. The Default Weighing Unit is set to be gram if [
9 ] is selected and ounce if [
o2 ] is
selected.
2. Press
button to switch the Default Weighing Unit between gram and ounce.
3. Press and hold
button for 1 second until [ rESoL ] is shown on LED to confirm the selected
option.
Chapter 4: Configuration
22
Weighing Resolution Setting [ rESoL ]
1. The default Weighing Resolution is set to [ dEFAUL ]: the division is 0.1g / 0.02oz.
2. Press
button to switch the weighing resolution between [ dEFAUL ] and [
hiGh ].
3. When the Weighing Resolution is set to high, division will be 0.01g/0.0005oz. The default
0.00 ] in Weighing Mode.
display will show [
4. Press and hold
button for 1 second until [ NoDE_1 ] is shown on LED to confirm the selected
option.
5. Note : After setting Weighing Resolution to high, the default display will show [0:00 0.00] with
timer in Dual Display Mode and Auto Start Modes.
Weighing Mode Setting [ NoDE_1 ]
1. The default Weighing Mode Setting is set to ON, which means this mode is enabled.
2. ON: The Weighing Mode is enabled.
3. OFF: The Weighing Mode is disabled.
4. Press and hold
button for 1 second until [ NoDE_2 ] is shown on LED to confirm the selected
option.
Dual Display Mode Setting[ NodE_2 ]
1. The default Dual Display Mode Setting is set to ON, which means this mode is enabled.
2. ON: The Dual Display Mode is enabled.
3. OFF: The Dual Display Mode is disabled.
4. Press and hold
button for 1 second until [ NoDE_3 ] is shown on LED to confirm the selected
option.
Auto Start Mode
Setting[ NodE_3 ]
1. The default Auto Start Mode with Droplet Setting is set to ON, which means this mode is
enabled.
2. ON: The Auto Start Mode with Droplet is enabled.
3. OFF: The Auto Start Mode with Droplet is disabled.
4. Press and hold
button for 1 second until [ NoDE_4 ] is shown on LED to confirm the selected
option.
Chapter 4: Configuration
23
Auto Start Mode
Setting[ NodE_4 ]
1. The default Auto Start Mode with Droplet and Square Setting is set to ON, which means this
mode is enabled.
2. ON: The Auto Start Mode with Droplet and Square is enabled.
3. OFF: The Auto Start Mode with Droplet and Square is disabled.
4. Press and hold
button for 1 second until [ NodE_5] is shown on LED to confirm the selected
option.
Auto Start Mode
Setting[ NodE_5]
1. The default Auto Start Mode with Triangle and Square Setting is set to ON, which means this
mode is enabled.
2. ON: The Auto Start Mode with Triangle and Square is enabled.
3. OFF: The Auto Start Mode with Triangle and Square is disabled.
4. Press and hold
button for 1 second until [ rESEt.d ] is shown on LED to confirm the
selected option.
Reset Password Setting [ rESEt.d ]
1. Select [ YES ] to clear the bluetooth connection password.
2. Press and hold
button for 1 second until [ bt_SEt ] is shown on LED to clear the password.
Bluetooth Setup Setting [ bt_SEt ]
1. OFF: The bluetooth is disabled. The scale does not allow any bluetooth connection.
2. ON: The bluetooth is enabled. The scale allows bluetooth connection. User may connect the
scale with acaia Apps.
3. Press and hold
Chapter 4: Configuration
button for 1 second until [ SLEEP ] is shown to confirm the modification.
24
Appendix A. Smart-Calibration
If you decide to calibrate your scale, it will only be as good as the accuracy of the calibration
weights you use.
*Note : If you use weights other than acaia Weights, we recommend standard weights with class F1
or F2.
Calibration Mode
1. While the scale is in Weighing Mode and the weighing unit is in gram, press
multiple times until LED display shows [ CAL
button quickly
] and then [ 500.00 ].
2. Place a acaia 100 weights on scale and wait for the scale to execute calibration procedure.
3. The LED display shows [ _End_ ] when the calibration procedure is completed. You may
unload the calibration weight when completed.
Note:
1. If your Weighing Mode is disabled, please refer to Chapter 4: Weighing Mode Setting to turn
on.
2. If you use weights other than acaia Weights, we recommend standard weights with 100g*n. For
example, 500g or 1000g.
Appendix A. Smart-Calibration
25
Appendix B. Display Codes
Error Code List
Error Code
Description
100 Code error
101 EEPROM error
102 AD read error
Over load: the weight is over the maximum capacity.
Under load: the weight is under the minimum capacity.
303 Unable to make zero point, for the initial weight exceeds the limit (50% of capacity).
304 Weight calibration error.
904 Password error (the default password is 0000)
_H2O Water in the Power Button
H2O_ Water in the Tare Button
_H2O_ Water in the Power Button and Tare Button
Others
Display Code
UPdAtE
Description
The scale is in update mode.
Note: If you want to leave update mode, please plug the scale's USB to a power source.
Appendix B. Display Codes
26
Copyright
The operation manual is protected by copyright. All rights reserved. No part of the operation
manual may be reproduced, processed, duplicated or published in any form by photocopying,
microfilming, reprinting or any other method, in particular electronic means, without the written
agreement of acaia.
© acaia, Cupertino, CA, 2015.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising