INTRODUCTION
The V-9936A is a Six Line C. O. Audible Ring Unit
to be used with Electronic key and PABX telephone
systems.
These instructions contain the specifications and
information necessary to install, operate, and maintain
the Six Line C. O. Audible Ring Unit.
When installing the V-9936A, notify the local
telephone company with the following information:
•
•
•
The telephone number of the lines to which the
V-9936A will be connected;
The FCC Registration number of the V-9936A,
which is BAF9I7-12995-RG-N; and
The ringer equivalence number (REN): 0.7B.
•
•
•
•
•
•
SPECIFICATIONS
Purpose
•
•
Monitors up to six C. O. Lines or PABX station
numbers and gives a common audible tone signal
and a dry relay contact closure to indicate
incoming ring on any of the lines.
V-9936A units may be multiplied to supervise
additional lines.
•
•
•
•
•
Input for a night switch (On/Off switch)
Built-in 66 type connection block
May be connected to an existing paging system
Drives up to 150 Valcom One-Way Amplified
Speaker Assemblies
Drives up to two 45 Ohm Talkback Speakers
May be used with One-way or Talkback Paging
Systems
May be used with 70 Volt Paging Systems
Ring tone will override any page in progress
Volume control
Power reversal indicator
Powered by –24 Vdc "B" battery
Capacity
Applications
•
•
•
•
•
Electronic key system C. O. lines
PABX trunks
PABX station numbers
1A2 key system C. O. lines
•
•
Features
•
•
•
•
•
•
Monitors six lines
Units may be multiplied for additional lines
Provides interrupted electronic warble tone
output for tone signaling
Provides interrupted dry contact closure output to
activate loud bells
Each V-9936A will provide signaling for six
C.O. lines or extension numbers
Up to four units may be multiplied for
monitoring of 24 lines
May be connected to one zone of a paging
system
The V-9936A will drive two 45 Ohm Talkback
speakers or 150 one-way amplified speaker
assemblies
The dry contact closure is rated at 1.0 amp @
105 Vac, or 2.0 amps @ 24 Vdc.
Sold by:
http://www.TWAcomm.com
Toll Free: (877) 892-2666
1
947961
•
•
Dimensions/Weight
•
•
8.2"H x 4.55"W x 2.3" D
(20.83cm H x 11.56cm W x 5.84cm D)
1.5 lbs. (.68 kg)
V-9936A C. O. Ring Units, 1 per 6 lines
VP-624B –24 Vdc Power Supply (VP-4024B if
using more than (3) V-9936A's).
If a page is in progress when an incoming call is
detected, the ring signal from the V-9936A will
momentarily override the page.
Power Requirements
–21.5 to –26 Vdc "B" Battery, 200 mA. max.
Environment
C.O.1
Temperature:
Humidity:
C.O.2
0 to 50 Degrees C
0 to 85% non-precipitating.
DESIGN
TELEPHONE
SYSTEM
PAGE
OUT
C.O.6
General
The Valcom V-9936A is designed to monitor up to
six C. O. lines or PABX station numbers and will
provide a common tone signal and contact closure
whenever any of the lines are ringing. The V-9936A
may be used with most telephone systems because it
connects directly to the lines and not to the phones.
The tone output may be connected to speakers used
only for ringing, or to one zone of a paging system.
The dry contact closure may be used to activate loud
ringing bells, strobes, or other external equipment.
Both outputs will provide interrupted signals
whenever any line is ringing.
(Page Control Unit
may not be required)
V-9936A
WARBLE
TONE
GENERATOR
FIGURE 1 - TYPICAL INSTALLATION
INSTALLATION
A disable input is provided for connection of a night
switch. With no switch connected, the V-9936A
will signal any time a line rings in. With a switch
connected and providing a short across the disable
input, the unit will be inactive.
Stand-Alone Ringing
The following components are required to provide
common audible ringing over dedicated bells or
speakers.
• V-9936A C. O. Ring Units, 1 per 6 lines
• Signaling Devices consisting of:
a. Two 45 Ohm talkback speakers, or
b. Up to 150 one-way amplified speakers, or
c. Loud bells, buzzers, strobes, etc. as required.
• Power Supply: The VP-624B will power a
V-9936A using talkback speakers for signaling.
If one-way speaker assemblies or other signaling
devices are used, additional power may be
required.
Ringing Over Paging
Ringing may be connected to one zone of a Valcom
One-way or Talkback Paging System, or to the
INPUT of a high powered amplifier. The following
components are required:
The following sections contain step-by-step
instructions for wiring the V-9936A and associated
Valcom equipment. Each instruction is preceded by a
line; place a check on the appropriate line as the
instruction is completed. The instructions also
include tests along the way to verify connections have
been made correctly. If these steps are followed
exactly, installation should go smoothly and quickly.
If the results of a test do not correspond with what is
shown, DO NOT PROCEED UNTIL THE
PROBLEM HAS BEEN CORRECTED.
Set individual volume controls at approximately 1/2
volume for testing when installing the control unit
and any one-way amplified speaker assemblies.
Mounting
Remove the metal mounting plate from the rear of the
V-9936A enclosure. Using two #6 3/4" wood screws,
mount the plate in a vacant space on the backboard
with the telephone system common equipment. Both
mounting holes must be utilized to insure secure
mounting of the unit. See Figure A.
Open the V-9936A enclosure to access connections
and option switches. Slide the rear of the unit
(contains the board) onto the mounting plate and lock
in place with screw provided. Make connections and
replace cover after all connections are accomplished.
Lock cover in place using the #6 1/2" screw provided.
Sold by:
2
http://www.TWAcomm.com
Toll Free: (877) 892-2666
947961
WIRE TIE LOOP
WIRE TIE USED TO BUNDLE WIRES
ENTERING AND LEAVING TERMINAL AREA
TO REMOVE COVER
LOOSEN SCREW,
THEN ACTIVATE LATCH
WIREWAY OPENING
TO WALL PLATE AND
JUNCTION BOX
METAL WALL
MOUNTING
PLATE
.155 DIA. HOLES FOR MOUNTING TO
SINGLE OR DOUBLE GANG JUNCTION BOX
HOLE PATTERN MATCHES BOTH EURO
AND US JUNCTION BOXES
SNAP LATCH
1.5 x 2 WIRE ACCESS OPENING
TO JUNCTION BOX
CIRCUIT BOARD
HOUSING ASSEMBLY
SNAP LATCH
FOR COVER
PLASTIC
COVER
BRACKET
LOCKING
SCREW
FIGURE A
Sold by:
http://www.TWAcomm.com
Toll Free: (877) 892-2666
3
947961
__ 3.
DO NOT locate the V-9936A or it's wiring
closer than 18" to a power supply or any
equipment that generates electrical noise.
__ 4.
Power Connections
__ 5.
__
__
NOTE: The steps below must be completed for each
V-9936A being installed.
__ 1.
__ 2.
Unplug power supply.
Connect –24 Vdc "B" battery (may be
referred to as "-" or "signal battery") from
power supply to pin 30 (-24 Vdc) on the
V-9936A.
__
__
__
__ 6.
Connect –24 Vdc Ground ("B" ground, "+",
or "signal" ground) from power supply to
pin 29 (GND).
Connect –24 Vdc ground (+) from power
supply to telephone system GND.
Power Test:
a. Plug in power supply.
b. If power reversal LED is lit (If not lit, go to step 6)
(a) Unplug power supply.
(b) Reverse connections on V-9936A, pins
29 (GND) and 30 (–24 Vdc).
(c) Go to step 6.
Unplug power supply.
FIGURE 2
V-9936A
Reverse Power LED
Do Not Adjust
Volume Control
LoZ
Speaker Select
Switch
HiZ
Connecting Block
15
30
1
16
GR
- 24
VD
C
OU
T
OU
ND
PA
OU
GE
T
CO IN T
NT
PA ACT
GE
CL
OS
-24 OU
UR
T
VD
T
E
C
OU
DI
SA
T
BL
EI
EX
N
PA
NS
IO
N
C.
O.
6T
IP
C.
O.
5T
IP
C.
O.
4T
I
C.
P
O.
3T
IP
C.
O.
2T
IP
C.
O.
1T
IP
LOCATION OF CONNECTING BLOCK AND CONTROLS
15 14 13 12 11 10
9
8 7 6 5 4 3 2 1
30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
G
IN
1R
O.
G
IN
C.
2R
O.
G
C.
IN
3R
O.
G
IN
C.
4R
O.
G
IN
C.
5R
G
O.
IN
C.
6R
O.
C.
UT
EO
BL
T
SA
OU
DI
ND
OU
TR
RE
GR E OU
SU
LO
G
PA
TC
AC
NT
R
CO
IN
G E IN
PA
ND
OU N
GR C I
VD
-24
CONNECTING BLOCK PIN DESIGNATIONS
Sold by:
http://www.TWAcomm.com
Toll Free: (877) 892-2666
4
947961
9.
__ (a)
__ (b)
__ (c)
If using Valcom speakers for signaling:
Connect Tip of speaker to pin 11.
Connect Ring of speaker to pin 26.
If using one-way amplified speaker
assemblies:
__ (1) Connect the -24VDC speaker lead to
V-9936A pin 10.
__ (2) Connect the Ground speaker lead to pin
25.
__ (d) Set the speaker select switch to HiZ if using
45 Ohm talkback speakers; or set it to LoZ
if using one-way amplified speakers.
10. If using Bells or other devices for signaling:
__ (a) Connect one side of the output of an
appropriate power source to pin 12 of the
V-9936A.
__ (b) Connect the other side of the power source
to one of the input terminals on your
signaling device.
__ (c) Connect from pin 27 of the V-9936A to the
other input terminal of your signaling
device.
__ (d) Consult the information supplied with the
signaling device for additional information.
__ 11. If adding a night switch, connect it to pins 9
and 24.
__ 12. Plug in power supply.
(See the Power Connection section)
__ 13. If using speakers for signaling, dial a line
connected to the V-9936A. When it starts
ringing adjust the V-9936A volume control
to the desired level.
Connecting Arrangements
•
•
•
Proceed to Figure 3 for Stand-Alone Ringing
Connections.
Proceed to Figure 4 for Ringing Over Paging
Connections.
Proceed to Figure 5 for telephone system
providing a dry contact closure for common
audible signaling.
WIRING INSTRUCTIONS:
Place a check by each step as it is completed.
__ 1. Connect Tip of the first Central Office Line
or PABX station number to the V-9936A pin
1 (C. O. 1 Tip).
__ 2. Connect Ring of the first line or station to
pin 16 (C. O. 1 Ring).
__ 3. Connect Tip of Line 2 to pin 2; and connect
Ring of the line to pin 17.
__ 4. Connect Tip of Line 3 to pin 3; and connect
Ring of the line to pin 18.
__ 5. Connect Tip of Line 4 to pin 4; and connect
Ring of the line to pin 19.
__ 6. Connect Tip of Line 5 to pin 5; and connect
Ring of the line to pin 20.
__ 7. Connect Tip of Line 6 to pin 6; and connect
Ring of the line to pin 21.
__ 8. If using multiple V-9936A's:
__ (a) Connect a group of 6 lines or station
numbers to each V-9936A as in steps 1-7.
__ (b) Connect wire from pin 8 (expansion) of the
main unit to pin 8 of each additional unit.
6 Central
Office or
Station
1 Lines
TO PIN 8 OF
ALL ADDITIONAL
V-9936A's
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
V-9936A
30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
24VDC
POWER
SUPPLY
NIGHT SWITCH
+
RING SUPPLY
SPEAKERS
LOUD BELL
FIGURE 3 - STAND-ALONE RINGING CONNECTIONS
Sold by:
http://www.TWAcomm.com
Toll Free: (877) 892-2666
5
947961
__10.
__(a)
If using Valcom paging speakers:
Note the location of the speaker wires on
the page control unit, and remove them.
__(b) Connect the speaker wires removed in (a)
to pins 11 (Tip) and 26 (Ring) of the
V-9936A.
__(c) Connect V-9936A pins 13 (Tip) and 28
(Ring) to the page control locations noted
in (a).
NOTE: If the page control unit provides a
background music input, the page out terminals may
be connected to the BGM input and the speakers
connected directly to the Page Control Unit.
11. If using a high power amplifier:
__(a) Disconnect the paging signal wires from the
INPUT of the amplifier, and connect them
to the V-9936A pins 13 and 28.
__(b) Connect V-9936A pins 11 (Tip) and 26
(Ring) to the amplifier INPUT.
__ 12. Set the speaker select switch to LoZ.
__ 13. If adding a night switch, connect it to pins 9
and 24.
__ 14. Plug in power supply. (See power
connection section).
__ 15. Dial a line connected to the V-9936A.
When it starts ringing, adjust the V-9936A
volume control to the desired level.
WIRING INSTRUCTIONS:
Place a check by each step as it is completed.
__ 1. Connect Tip of the first Central Office line
or PABX station number to the V-9936A pin
1 (C.O. 1 Tip).
__ 2. Connect Ring of the first line or station to
pin 16 (C. O. 1 Ring).
__ 3. Connect Tip of line 2 to pin 2; and connect
Ring of the line to pin 17.
__ 4. Connect Tip of line 3 to pin 3; and connect
Ring of the line to pin 18.
__ 5. Connect Tip of line 4 to pin 4; and connect
Ring of the line to pin 19.
__ 6. Connect Tip of line 5 to pin 5; and connect
Ring of the line to pin 20.
__ 7. Connect Tip of line 6 to pin 6; and connect
Ring of the line to pin 21.
8.
If using multiple V-9936A's:
__(a) Connect a group of 6 lines or station
numbers to each V-9936A as in steps 1-7.
__(b) Connect a wire from pin 8 (expansion) of
the main unit to pin 8 of each additional
unit.
__ 9. NOTE: Complete the wiring and testing of
the paging system, and properly adjust all
volume controls, before continuing.
6
1
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
Central
Office or
Station
Lines
V-9936A
30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
24VDC
POWER
SUPPLY
NIGHT SWITCH
+
PAGE CONTROL UNIT
AUDIO OUT
SPEAKERS
FIGURE 4 - RINGING OVER PAGING CONNECTIONS
Sold by:
http://www.TWAcomm.com
Toll Free: (877) 892-2666
6
947961
__ 3.
WIRING INSTRUCTIONS
Connect telephone system dry contact
closure to pins 15 and 8.
__ 2.
If using Valcom paging speakers:
__ (a) Connect audio output from page control
unit to pins 13 and 28.
__(b) Connect T & R of each Valcom speaker to
pins 11 and 26.
If using a high power amplifier, connect pins
11 and 26 to a line level input on the
amplifier.
If using a night switch, connect it to pins 9
and 24; when the switch is closed, the
V-9936A is disabled.
Set speaker select switch to the desired
position Lo Z (8 ohm) on a one-way system,
Hi Z (45 Ohm) on a Talkback System.
Plug in power supply.
(See the Power Connection section).
Test system and adjust volume as required.
__ 1.
__ 4.
__ 5.
__ 6.
NOTE: If the page control unit provides a
background music input, the page out terminals may
be connected to the BGM input and the speaker
connected directly to the Page Control Unit.
__ 7.
TELEPHONE SYSTEM
DRY CONTACT CLOSURE
FOR NIGHT RING
V-9936A
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
24VDC
POWER
SUPPLY
NIGHT SWITCH
+
PAGE CONTROL UNIT
AUDIO OUT
SPEAKERS
FIGURE 5 - CONNECTIONS FOR A TELEPHONE SYSTEM
WITH A COMMON AUDIBLE CONTACT CLOSURE
Sold by:
http://www.TWAcomm.com
Toll Free: (877) 892-2666
7
947961
OPERATION
TECHNICAL ASSISTANCE
When a line rings in, the control circuitry and timer
are activated. While sensing the first incoming ring,
the unit will activate the output relay, disconnect the
page source, and send a one second warble tone and
dry contact closure to the output. The relay will then
drop, and paging will be reconnected. If additional
incoming rings are sensed during the next 4 seconds,
a second tone and closure will be sent. One second
tones and closures will then be sent every 4 seconds
for as long as ringing is sensed on any line. If several
units are connected together using the expansion
leads, all units will send tones if a line rings in on any
unit. Connecting the disable lead (pin 9) to ground
(pin 24) will prevent the unit from being activated.
Connecting a switch between these pins will allow
use of the V-9936A for night ringing. A simplified
schematic of the V-9936A is shown on the next page.
When trouble is reported, verify power is being
supplied to the unit and there are no broken
connections. Check voltages for proper polarity on
the crossconnect block. Table 1 identifies symptoms
of some possible problems with solutions. If a spare
unit is available, continue to troubleshoot by
substituting the spare unit for the suspected defective
unit.
Assistance in troubleshooting is available from the
factory. When calling, you should have a VOM,
several clip leads, a telephone test set available, and
be calling from the job site. Call (540) 427-3900 and
ask for Technical Support, or (540) 427-6000 for
Valcom 24-hour Automated Support or visit our
website at http://www.valcom.com.
The V-9936A is not field repairable. Valcom
equipment contains no user serviceable parts
inside. Valcom, Inc. maintains service facilities in
Roanoke, VA. Should repairs be necessary, attach a
tag to the unit clearly stating your company name,
address, phone number, contact person, and the
nature of the problem. Send the unit to:
Valcom, Inc.
Repair and Return Dept.
5614 Hollins Road
Roanoke, VA 24019-5056
TABLE 1: TROUBLESHOOTING CHART
PROBLEMS
POSSIBLE SOLUTIONS
1. No ring.
1A. Verify –24 Vdc and ground on pins 30 and 29. Power reversal LED
should not be on.
1B. Verify Disable In (Pin 9) is not grounded or connected to Disable
Out (pin 24).
2. Certain lines do not ring.
2A. Verify trunk Tip and Ring connections
3. Expansion unit does not
ring.
3A. Verify proper connection between Expansion Input leads (pin 8) of
units.
4. Low output to 45 Ohm
speaker.
4A. Set Option Switch to Hi Z.
4B. Turn V-9936A volume control up.
5. Overdrives amplified
speaker.
5A. Set Option Switch to Lo Z.
5B. Turn V-9936A volume control down.
6. Paging volume incorrect.
6A. Adjust paging system volume according to instructions supplied with
paging system. NOTE: The paging system volume MUST be
properly set before adjusting the volume control on the V-9936A.
Sold by:
http://www.TWAcomm.com
Toll Free: (877) 892-2666
8
947961
EXPANSION
C.O.1
C.O.2
VOLUME
CONTROL
RING
DETECT
RING
DETECT
PAGE IN
CONTROL
AND
TIMING
CIRCUIT
TONE
GEN.
AMP
PAGE OUT
OPTION
SWITCH
C.O.6
RING
DETECT
SIMPLIFIED SCHEMATIC OF V-9936A
CONTACT
CLOSURE
VALCOM LIMITED WARRANTY
Valcom, Inc. warrants its products to be free from defects in materials and workmanship under conditions of normal use and service
for a period of one year from the date of shipment. The obligation under this warranty shall be limited to the replacement, repair or
refund of any such defective device within the warranty period, provided that:
1.
2.
3.
4.
5.
inspection by Valcom, Inc. indicates the validity of the claim,
the defect is not the result of damage, misuse, or negligence after the original shipment.
the product has not been altered in any way or repaired by others and that factory sealed units are unopened (A service
charge plus parts and labor will be applied to units defaced or physically damaged),
freight charges for the return of products to Valcom are prepaid,
all units ‘out of warranty’ are subject to a service charge. The service charge will cover minor repairs (Major repairs will be
subject to additional charges for parts and labor).
This warranty is in lieu of and excludes all other warranties, expressed or implied, and in no event shall Valcom, Inc. be
liable for any anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection
with the purchase, operation, or use of the product.
This warranty specifically excludes damage incurred in shipment. In the event a product is received in damaged condition, the
carrier should be notified immediately. Claims for such damage should be filed with the carrier involved in accordance with the
F.O.B. point.
Headquarters:
Valcom, Inc.
1111 Industry Avenue
Roanoke, VA 24013
Phone: (540) 427-3900
FAX: (540) 427-3517
In Canada
CMX Corporation
35 Van Kirk Drive #11 and 12
Brampton, Ontario L7A1A5
Phone: (905) 456-1072
FAX: (905) 456-2269
Sold by:
http://www.TWAcomm.com
Toll Free: (877) 892-2666
9
947961
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising