Fire Control Panels
Fire Control Panels
Introducing the 4100ES Series of
Fire Detection and Control Products
Features
4100ES control panels introduce a new appearance
with new features while continuing to support the
®
extensive and proven Simplex fire detection and
control product features:
4100ES products are designed, tested, and listed as
compatible with the remote modules and peripherals
used with 4100U series fire alarm control panels*
Both local and remote control panels are available with
an InfoAlarm™ Command Center user interface
Equipment cabinets are available in 1, 2, or 3 bay sizes
with color choices of platinum or red
Upgrade kits are available to provide 4100ES features
for installed Simplex control panel models 4020, 4100,
4100+, and 4120
Support is provided for:
TrueAlarm® sensing and detection products including
TrueSense® multi-sensor products for early fire
detection
TrueAlert® addressable and non-addressable notification
appliances, including SmartSync™ horn/strobe control
IDNet™ digital communications for addressable I/O
modules, NAC extenders, and related products
Remote annunciator RUI (remote unit interface)
communications ports, and for up to five RS-232
communications ports for multiple remote equipment
operation options
Installation and test convenience that includes
WALKTEST™ single person system testing, available
with multiple interface options
The available TrueStart™ test instrument that allows
communications wiring to be tested and corrected if
necessary before panel modules are installed
NEW Install Mode operation:
Install Mode allows grouping of multiple troubles for
uninstalled modules and devices into a single trouble
condition (typical with future phased expansion)
With future equipment and devices grouped into a
single trouble, operators can more clearly identify
events from the commissioned and occupied areas
NEW Options provide secure time-saving service
tools for authorized personnel:
The Building Network Interface Module (BNIC)
provides Ethernet connectivity options for authenticated
users to access panel information using service PC tools
The Service Gateway tool allows a single authorized
service person to perform remote device testing using
text messaging tools to query panel status and confirm
work is completed as expected without returning to the
panel
TrueInsightSM Remote Service programs provide
real-time intelligence and diagnostics for increased
uptime and enhanced fire alarm system performance
4100ES 3-Bay Cabinet, shown with optional: InfoAlarm
Command Center, and Emergency Voice Equipment
Introduction
4100ES Series Fire Detection and Control Panels
provide extensive installation, operator, and service
features with point and module capacities suitable for a
wide range of system applications. An on-board Ethernet
port provides fast external system communications to
expedite installation and service activity. Dedicated
compact flash memory archiving provides secure on-site
system information storage of electronic job configuration
files to meet NFPA 72® (National Fire Alarm Code®)
requirements.
Modular design. A wide variety of internally mounted
modules are available to meet your specific application
requirements. Panels can be configured for either
Stand-Alone or Networked fire control operation with
wired communications or using fiber optics.
Emergency Communications. Emergency
communications system equipment is available for both
fire alarm and emergency communications/mass
notification applications. Amplifiers can be centrally
located or distributed at remote MINIPLEX® transponder
locations. Audio can be distributed using analog or digital
means with either wired communications or with fiber
optics connections.
* Refer to individual product data sheets for specific listing details. See partial data sheet
list on page 2.
S4100-0060-1
4100ES Control Panel Size Reference
24" (610 mm)
ABC
Z ONE
1
J KL
FB
ALARMS
Fire Alarm Priority 2 Alarm
3 Bay height =
56" (1422 mm)
SYSTEM WARNINGS
Supervisory
Trouble
AC Power
Alarm Silenced
Priority2
Ack
Event
Time
Supv
Ack
Trouble
Ack
Alarm
Silence
More
Info
DE F
SIG
G HI
AUX
2
3
PQ R
IDNet
5
V WX
P
System
Reset
M NO
IO
4
ST U
7
Fire Alarm
Ack
A
8
' SP' ( )
,0 :
NET
ADDR
6
YZ/
L
9
0
DEL
Enter
C/Exit
Previous
Menu
Enable
On
Arm
Disable
Off
Disarm
Next
Auto
Lamp
Test
Emergency Operating Instructions
Alarm or Warning Condition
How to Silence Building Signals
System indicator flashing.Tone On.
Press Alarm Silence.
How to Acknowledge / View Events
How to Reset System
Press ACK located under flashing indicator.
Repeat operation until all events are acknowledged
.
Local tone will silence.
Press System Reset.
Press Ack to silence tone device.
2 Bay height =
40" (1016 mm)
On
On
Off
Off
Auto
Auto
On
On
Off
Off
Auto
Auto
On
On
Off
Off
Auto
Auto
On
On
Off
Off
Auto
Auto
1 Bay height =
22" (559 mm)
Additional Data Sheet Reference
Subject
Data Sheet
Subject
4100ES Basic Panel Modules and Accessories
S4100-0031
Network Display Unit (NDU)
S4100-0036
Data Sheet
LED/Switch Modules
S4100-0032
Remote Annunciators
S4100-0038
4100ES Audio/Phone Modules
S4100-0034
InfoAlarm Command Center
S4100-0045
MINIPLEX Transponders
S4100-0035
Enclosure Options
S4100-0037
Releasing Systems Applications
S4100-0040
Fire Alarm Network Reference
S4100-0055
Building Network Interface Card
S4100-0061
TrueAlert Addressable Reference
S4009-0003
Multiple Signal Fiber Optic Modules
S4100-0049
IDNet+ Communications Module
S4100-0046
Tyco is a registered trademark of Tyco International Services GmbH and is used under license. Simplex, the Simplex logo, IDNet, TrueAlarm, SmartSync, WALKTEST,
MINIPLEX, TrueAlert, TrueSense, TrueInsight, and InfoAlarm are trademarks of Tyco International Ltd. and its affiliates and are used under license. NFPA 72 and National Fire
Alarm Code are registered trademarks of the National Fire Protection Association (NFPA).
Tyco Safety Products Westminster • Westminster, MA • 01441-0001 • USA
www.tycosafetyproducts-usa-wm.com
S4100-0060-1
© 2011 Tyco Safety Products Westminster. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising