RO-175 / REVERSE OSMOSIS SYSTEM
The SFES RO 175 is designed to meet the high water quality standards demanded by specialty water-fed low-flow
food service equipment such as steamers, combination ovens, proofers, rack and deck ovens. Water containing
high amounts of dissolved solids and hardness adversely affects the operation and life of water-fed equipment,
especially in high temperature environments where water is evaporated. Mineral scale deposits dramatically
increase maintenance costs and downtime, while decreasing equipment life due to corrosion.
The SFES RO-175 removes up to 98% of dissolved minerals from the water supply providing excellent quality
water for processes that are sensitive to mineral scale deposits and corrosion caused by certain water impurities.
Standard Features
Versatile & Economical - Self contained storage tank allows the unit to be used without an external storage tank in
low water flow applications saving space and costs. If needed, a larger external storage tank may be used for
higher water volume demands.
Small Space Requirement - Measuring only16”x16”x5” the complete self contained unit takes up little space and
can be wall mounted or set on a table or shelf.
Quick disconnect bulk head unions make installation a snap.
,
Easy to Service - The primary cartridge and RO membrane are
quick disconnect filters making the filter change quick and easy.
APPLICATIONS INCLUDE:
*
*
*
*
*
Steamers & Combination Ovens
Proof Boxes
Deck & Rack Ovens
Espresso / Cappuccino Machines
Misting Systems
BENEFITS INCLUDE:
Inlet
Valve
Inlet
Port
TDS
Meter
Outlet
Port
Scale Prevention & Corrosion Control Resulting In: Drain
Port
* Reduced Equipment Maintenance Costs
* Reduced Equipment Downtime
* Increased Equipment Life
* Decreased Operating Costs
RO- 175 Membrane
TDS Meter - Built in TDS Meter allows the user to monitor RO
system performance by reading the incoming and outgoing TDS
of the water.
To Inlet
TDS
Meter
TOS-10 Chlorine / Scale Control
Effective Performance - Incorporation of a Permeate Pump
ensures excellent performance guarantying lowest product
water / waste water ratio possible. ScaleStick insert inside
primary cartridge extends membrane life and improves
performance.
Tank
Valve
To Outlet TDS Meter
Storage Tank
Permeate
Pump
800 ml
Drain Flow Controller
Specifications:
RO Dimensions
Production
Max. Temperature
Min/Max Pressure
Filter requirements
Storage Tank (standard)
Connection Sizes
16”h x 16”w x 5.5”d
175 gpd / 7.25 gph (Based on 60 psi incoming pressure @ 65°F water temp.)
100°F
40-80 psi (if pressure exceeds 80 psi, use a pressure regulator)
(1) TOS-10 Primary Cartridge
(1) RO-175 Membrane
.5 Gallon / .27 Gallon draw down ( total amount of water that can be used at one
given time. If more water is required, a larger storage tank may be used inline
with the equipment external from the RO-175 system.)
Inlet/Outlet - 3/8” Push Connect Fittings
Drain - 1/4” Push Connect Fitting