JPI EGT-701 Exhaust Gas Temperature Scanner Installation manual
Below you will find brief information for Exhaust Gas Temperature Scanner EGT-701. This document provides a detailed guide on installing the EGT-701 scanner, including instructions for probe placement, wiring, and calibration., It covers a variety of options, including fuel flow, TIT, OAT, IAT (induction air temp.), OIL, BAT (voltage) and RPM. It also includes instructions for troubleshooting and operating the scanner.
Advertisement
Advertisement
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER®
1/20/09
Rev-E
THE OWNER OF THIS EDM-700/800/730/830
MUST KEEP THIS MANUAL
TABLE OF CONTENTS
Page
1) INSTALLING THE INDICATOR
2) EXHAUST GAS TEMPERATURE PROBE
3
3
3) TURBINE INLET TEMPERATURE PROBE
4) CYLINDER HEAD TEMPERATURE PROBE
5) SPARK PLUG GASKET CHT PROBE
3
4
4
6) INDUCTION AIR TEMPERATURE PROBE
7) OIL TEMPERATURE PROBE
8) OIL PRESSURE TRANSDUCER
9) OUTSIDE AIR TEMPERATURE PROBE
10) FUEL FLOW OPTION
11) WIRING
12) EGT AND CHT PROBE WIRING
13) ROUTING THE WIRING HARNESS
14) MANIFOLD PRESSURE INSTALLATION & CALIBRATION
15) RPM SENSOR INSTALLATION
17) INDICATOR INSTALLATION & RECORD
4
5
7
7
8
9
9
11
12
13
14
16
16
16 19) LIMITATIONS & OPERATION
20) COMPONENT PARTS LIST FOR EGT PROBE
21) COMPONENT PARTS LIST FOR CHT PROBE
22) COMPONENT PARTS LIST FOR OIL PROBE
23) COMPONENT PARTS LIST FOR OAT PROBE
24) COMPONENT PARTS LIST FOR MANIFOLD PRESSURE
25) COMPONENT PARTS LIST FOR RPM
26) COMPONENT PARTS LIST FOR SINGLE ENGINE EGT/CHT
17
17
17
17
17
17
17
27) WEIGHT AND BALANCE DATA
28) CHANGING PROGRAMMED LIMITS
29) TROUBLE-SHOOTING
FIG-1 INSTRUMENT BEZEL TEMPLATE
FIG-2 EGT/CHT/TIT PROBE PLACEMENT
FIG-3 EGT PROBE INSTALLATION
FIG-6 EGT/CHT PICTORIAL LAYOUT
FIG-7 WIRING DIAGRAM DRAWING 300701
FIG-9 DRAWING 700744 FUEL FLOW WIRING
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS (ICA)
17
18
20
22
23
24
25
26
27
28
J.P.INSTRUMENTS Inc.
PO BOX 7033
HUNTINGTON BEACH CA 92646
FAA APPROVED 10-28-09
Last printed 05/16/13
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 2 of 30
READ THIS FIRST
The following notes apply to a new installation. Read this section before proceeding. a) The JPI warranty found in the back of the pilots guide clearly states that JPI will replace defective parts under warranty, but does NOT cover labor to remove or install any parts. b) To prevent damage to the display it is essential that the four mounting screws not penetrate the
instrument more than 0.12 inches. Damage caused by screw penetration is not covered under warranty. c) You must be an FAA certified aircraft mechanic to install this instrument. d) Check that any necessary FAA approvals (STC’s, etc) are available for the aircraft before beginning the installation. e) The most common cause of probe problems is poor terminal crimps. Crimp ring terminals with AMP part
45518 crimp tool or equivalent. Fold back the wire double before crimping terminals.
Thermocouple wire harness
2 1/4" yellow
Fold back wire double before crimping terminals red
1/4" 1 1/2" f) This installation will require some parts unique to your aircraft that are not supplied with the kit,
(including but not limited to tie-wraps, hoses and fittings). Acquire all the necessary parts prior to beginning the installation. g) Do NOT use aluminum fittings with the FXT-201 or FXT-231 fuel flow transducer. h) Write down the K-factor engraved on the side of the fuel flow transducer here _______. Once the transducer is installed and covered with the fire sleeve, you will not be able to access this K factor. i) Determine the locations of all holes before drilling to ensure that nothing interferes with the probe, clamp, clamp screw or wire. j) Provide service loops at the instrument. k) Thermocouple wire length is not critical. Trim to required length, allowing for service loops at the engine so that probes can be swapped with probes on adjacent cylinders for troubleshooting purposes. l) Dress all wires away from high temperature components such as exhaust stacks. m) Never splice thermocouple wire using copper wire. Use only K-type thermocouple wire. Solder using zinc chloride flux such as Nokorode brand – rosin flux alone won’t work. n) Observe correct polarity on all probe wires. Connect like colors together (red to red, yellow to yellow). o) This instrument must be grounded at the engine, not at the avionics ground. p) If a spark plug gasket probe is used, expect the CHT reading on that cylinder to be somewhat higher than on the cylinders with bayonet probes. At additional cost an adapter probe (bayonet or screw-in) is available that permits the factory CHT probe and the JPI probe to be placed in the same bayonet location.
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 3 of 30
1) INSTALLING THE INDICATOR
Installation
Should Be Done In Accordance With Advisory Circular AC43.13-1A. All Models have the same basic
Part No. EGT-701 ( ).
EDM-700/800 Model :A steel template supplied with the installation kit is used as a guide for drilling two button holes in the instrument panel. Align and Mount the Template into the instrument panel hole. First drilling a 0.125 hole.
Remove the template and check the instrument alignment, if OK redrill with a 0.147 drill. Buttons can be removed by pulling off. The EGT-701 mounts in a standard 2.25” or 3 1/8” instrument hole. The instrument configures itself
automatically for 4 to 9 cylinders, 14/28 volt aircraft. The instrument is 7.5” deep less connectors and is 2.6 square behind the panel.
TO PREVENT DISPLAY DAMAGE IT IS ESSENTIAL THAT THE FOUR MOUNTING SCREWS NOT PENETRATE
THE INSTRUMENT MORE THAN .12 INCHES.
DAMAGE OF THIS NATURE IS NOT COVERED UNDER WARRANTY.
EDM-730/830 Model: Mounts in a standard 3.1/8” instrument hole. First place the mounting bracket on the instrument and tighten the clamp hex screw until you can just remove the instrument from the bracket. The Mounting bracket is then placed behind the instrument panel hole and screwed (6-32 x ½” screws) in place using the existing holes. Three screws should be used leaving one hole vacant on either side of the hex screw. Locate the hex screw in a location that you can easily get to from the rear of the panel. The body of the instrument is 3.0 inches and 2.0 inches deep less connectors. The body of the instrument is 3.0 inches and 2.0 inches deep less connectors.
2) EXHAUST GAS TEMPERATURE PROBE (EGT)
The Model M-111 Probe will fit any existing holes in the exhaust stack in any engine having the diameter of 1/8" to
1/4". If no hole exists, it will require the drilling of a 1/8" diameter hole and ream to fit. It is important that each probe be mounted a uniform distance from the exhaust stack flange. A nominal distance of 2 to 4 inches from the exhaust flange is recommended. (See fig-2). If the recommended distance is impractical because of obstructions, slip joints or bends in the exhaust system then position the probes a uniform distance from the flange as space permits. Be certain to locate all holes BEFORE drilling to ensure that nothing interferes with the probe, clamp, clamp screw or wire.
Careful matching of probe position will provide best temperature readings. Insert the probe in the exhaust or previously drilled hole (see fig-3) so that the tip of the probe is in the center of the exhaust stream. Tighten the stainless steel clamp to a torque of 45 in/Lbs. Cut off the excess strap close to the screw. Probe warranty is void if mounted in a slip-joint of any kind.
RADIAL ENGINES , EGT
Radial engine exhaust, require a larger EGT clamp (supplied) to fit the 2.5 inch exhaust pipe. The EGT probe is installed in the same fashion as a Lycoming or Continental engine and should be placed between the exhaust pipe flange and the accumulator at a distance of 2 to 3 inches form the engine exhaust flange. Cylinder head temperatures are measured with a spark plug gasket type probe placed under the front sparkplugs. Refer to the engine manufactures red line and set the EDM-700 appropriately. Front spark plugs will read 15 to 20 degrees cooler than the rear plugs. Do not route the EGT/CHT harness in with the ignition harness. Do not extend the yellow thermocouple leads with copper wire.
3) TURBINE INLET TEMPERATURE PROBE (TIT)
The standard TIT probe P/N M-111-T with a special clamp is placed in the exhaust stack accumulator to a maximum depth of 1/2 inch and approximately four (4) inches from the Turbine inlet if possible, on the wastgate side of the turbine. TIT will appear as the seventh column “T “and the expression “1650 TIT” will be seen when the dot is in place over it. The EDM-700 input is also compatible with the aircraft’s factory TIT and may be piggy backed.
The EDM-700 TIT cable may be connected in parallel (piggyback) at the TIT probe (preferred), or at the ship's TIT gage. Check the TIT readings between the EDM and the ships TIT gage in flight, then do the following calibration procedure. (This may be done in flight or on the ground.)
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 4 of 30
Press & hold 'STEP' and 'LF' keys simultaneously until you see
'PROGRAM' and 'RATE 4'. (Note: Bargraph disappears)
Now press & hold 'STEP' and 'LF' simultaneously again until you see
'ORIG. TIT' and 'ORIG. T-N'.
Tap 'LF' once to change to
'ORIG. T-Y'.
Tap 'STEP' once to display
'CAL TIT' and 'TIT+ 0'.
This is the correction added to (+), or subtracted from (-) the EDM reading for TIT (at high temperatures).
Hold in 'LF' to raise the correction, or tap 'LF' to lower it.
For example, if the EDM read 100 less than the ship's TIT,
Then hold in 'LF' until you see
'TIT+100'.
Adjust the correction slightly if a difference between the EDM
and the ship's gage still exists.
Now tap 'STEP' once to complete setup.
4) CYLINDER HEAD TEMPERATURE PROBE (CHT), BAYONET
The Bayonet probe 5050-T has the 3/8-24 adaptor boss as part of the probe and is screwed into the base of the cylinder (See fig-2). The bayonet probe has a screwdriver slot to facilitate tightening.
NOTE: Required original equipment that has a Red Line may not be replaced by the EGT-701 TIT or CHT installation.
This includes but is not limited to all aircraft with adjustable cowl flaps and on aircraft with placards on the instrument panel showing a climb air speed, for cooling, different from the best rate of climb air speed.
If a previously installed TIT, CHT or EGT is listed on the aircraft equipment list as Optional Equipment or not listed at all, it may be replaced by the EGT/CHT SCANNER.
5) CYLINDER HEAD TEMPERATURE PROBE (CHT) SPARK PLUG GASKET
Most factory installed cylinder head temperature gauges utilize a bayonet or screw-in resistive type probe that occupies one of the bayonet sockets. This probe is not compatible with the thermocouple probes required for the
EGT-701.
The spark plug gasket probe, P/N M-113, replaces the standard copper spark plug gasket on one spark plug. The plug chosen, upper or lower, should be the one that provides the best correlation with the other temperature probes.
Due to the spark plug location, the gasket probe may read 25 o
F higher or lower than the factory probe. The probe is usually placed on the plug that receives the most direct cooling air. After many removals the probe may be annealed for re-use. Heat and quench in water. At additional cost an adapter probe P/N M-113-3/8 is available that permits the factory CHT probe and a JPI probe to fit the same bayonet location.
6) INDUCTION AIR TEMPERATURE PROBE (IAT) / CARB TEMP
.
Induction Air temperature probe, IAT, is installed just after the inter-cooler (OUT) and the Compressor Discharge
Temp (CDT) just before the inter-cooler (IN). The probe is an EGT probe and installed the same way as an EGT probe. A large clamp is supplied to fit around the airport leaving the inter-cooler or a 1/8 NPT is available. IAT option is displayed as an independent digital temperature like "125 IAT". On non-turbo engines the IAT in reality is the
Carburetor temperature and displayed as “34 CRB”.
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 5 of 30
7) OIL TEMPERATURE PROBE
The Oil Temperature Probe PN 400505-C or 400505-L is installed as a supplemental oil temperature indicator.
Lycoming Engines: The -L part number is for all Lycoming direct drive engines and is installed in the right (passenger side) front oil galley by removing the existing 1/8 NPT plug on the passenger side of the engine and inserting the optional JPI oil probe supplied with the kit. Oil temperature will be displayed as an independent temperature like "230
OIL" and will be displayed In the seventh column automatically if TIT is not available. The original oil temperature gauge and sensor must remain. Check for oil leaks and safety wire before first flight.
Oil Probe Location Alternate Oil Probe
Location
front view
Lycoming Engines
Continental Engines: The -C part number is for all Continental direct drive engines and is installed in the left (pilot side) front oil galley by removing the existing 3/8 or 1/8 inch NPT plug (see figure below) located on the front, pilots side of the engine. Insert the optional JPI oil probe supplied in the kit. For 3/8 inch NPT installations, use the supplied brass adapter. An alternate location is on the top, front of the engine on the pilot’s side, where the probe is inserted vertically. There are two 1/8 NPT plugs close together. Install the probe in the position that is above and to the rear of the nearby position.
Alternate Oil Probe
Location
front view
Alternate Oil Probe
Location
Continental Engines
Oil Probe Location
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 6 of 30
Continental Engines Oil probe location
Alt location IO-520/550
Std oil IO-360
Alt location
IO-360
O-470
Requires ¼ NPT to 1/8 NPT reducer Oil reports after thermostat opens
Alternate Oil
Location
IO-520/550
IO-520/550
The oil probe P/N 400505-C is installed by removing the 3/8 or 1/8 pipe plug located on the front of the engine inline with the push rods. This oil galley feeds the valve lifters. Insert the JPI 1/8 NPT probe supplied with the kit. Check for leaks after installation. Due to cowling restrictions the alternate oil location may be chosen. The probe leads are routed back to the cockpit along with the EGT wires. Do not install the Oil Probe in the rear of the engine near the vernatherm (oil temperature regulator).
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 7 of 30
8) Oil Pressure Sensor Installation
Use the J3 connector harness 790420 labeled OIL-P for a VDO pressure sensor (shown in diagram below). Oil pressure sensor mounts using an aluminum clamp MS21919. Mount to firewall or tie wrap to existing wiring bundle.
Mount the pressure sensor to the pressure line using a flexible hose and fittings (not supplied) as depicted in the drawing below. Use aluminum clamp to mount the pressure sensor to firewall. Do not mount the sensor directly to the engine. Connect the other end of the hose to the engine manufacturer’s recommended location for engine oil pressure. An alternate method of installation is to install a T-fitting (not supplied) in the aircraft’s oil pressure gage line in the cockpit near the oil pressure gage. Their is no polarity on the oil pressure transducer wires.
AN-910-1D
1/8 NPT coupling pressure sensor
PN 30601 mount using
MS21919 -DG24
1.5 inch clamp
AN-816-4D
1/8 NPT to flared
MIL-H-8794 hose
MS-24587 fitting (AEROQUIP 491, 2 req'd) flexible tube 6 inch (AEROQUIP 303) installer.
to engine fitting
DO NOT MOUNT SENSOR DIRECTLY TO ENGINE
Transducer supplied by JPI, all other hardware supplied by
9) OUTSIDE AIR TEMPERATURE PROBE, OAT
Install the OAT probe, P/N 400510 in the airframe manufactures recommended location. If this is not possible, it is recommended that the OAT probe be placed in clean airflow such as in a cabin air scoop or below the underside of the wing away from engine heat or exhaust. In this case it is recommended that the installation be done similar to the antenna installation instructions of AC 43.12-2a "Acceptable Methods, Techniques and Practices". The outside aluminum tube is used to both hold the probe in place and shield it from radiated heat. OAT option is displayed as an independent digital temperature like "75 OAT". Be sure that when testing the OAT it is not in direct sun and the engine is running. aircraft sheet metal shield tube used to secure probe probe washer washer
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 8 of 30
10) FUEL FLOW OPTION
The EGT-701 receives signal from any installed Flowscan Transducer of the following Flowscan P/N’s embossed on to the top of the transducer. The K-Factor is engraved on the side of the Transducer. Wire per drawing 700744, Route the JPI wires along the existing wiring bundle lacing every foot.
Flowscan Instruments, Seattle WA 98106
FlowScan PN Shadin equivalent
PN
201-A
201-B 680501/680600
201-C
231 680503
Install the function switch in the panel per drawing 700124.
Select the appropriate installation configuration from the three following fuel system categories:
For gravity feed systems without a fuel pump use transducer FXT-231 (yellow plastic top). Connect the transducer between the fuel tank and carburetor.
For pump feed or fuel injected systems without
vapor return lines use transducer FXT-201 (black plastic top). Connect the transducer between the engine driven pump and servo/throttle body or carburetor.
For all fuel injected engines with vapor return lines to the fuel tank before the servo/throttle. use transducer FXT-201 (black plastic top). Connect the transducer between the throttle body and the fuel flow divider.
The transducer output port should be mounted lower or level with the carburetor inlet port (or fuel servo on a fuel injected engine). If this is not possible, an anti-siphon loop should be put in the fuel line between the fuel flow transducer and the carburetor or fuel servo.
Find a convenient location within 8 inches of a hose support or fitting to suspend the fuel flow transducer. Mount it away from any hot exhaust pipes. The hose support or fitting may be on the input or output line of the fuel flow transducer.
Secure the end of the transducer to any convenient point on the engine with MS21919
If the transducer is higher than the carburetor or fuel servo, put a loop between the transducer and carburetor or servo
OUT
SIDE VIEW carburetor
clamps or equivalent.
Do not place an
IN
or servo
angled elbow joint immediately
transducer
prior to the input port of the fuel
flow transducer.
There should be two inches of straight flow immediately before the transducer input port.
For a carbureted engine: remove the fuel hose which connects the carburetor to the fuel tank. Purchase two new hoses — one to connect the carburetor to the fuel flow transducer, and the other to connect the fuel flow transducer to the fuel tank. Before connecting the fuel hose to the carburetor, verify that the boost pump delivers at least 125 percent of takeoff fuel flow at minimum fuel pressure as marked on the fuel pressure gage.
For a pump-fed carbureted or fuel injected engine without vapor return lines: remove the fuel hose which connects the engine-driven pump and the servo/throttle body or the carburetor. Purchase two new hoses one to connect the engine-driven pump to the fuel flow transducer, and the other to connect the fuel flow transducer to the servo/throttle body or the carburetor.
For a fuel injected engine with vapor return lines before the servo/throttle: remove the fuel hose which connects the throttle body and the flow divider. Purchase two new hoses one to connect the throttle body to the fuel flow transducer, and the other to connect the fuel flow transducer to the flow divider. For Continental fuel injected engines adjust the fuel pressure to account for the pressure drop across the transducer per Continental Service Bulletin M89-10.
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 9 of 30
There must be flexible hose into and out of the fuel flow transducer. The hoses must meet TSO-C53a type C or D FAA specification. The new hoses must be the same size as the current hose in the aircraft. The fuel flow transducer must be wrapped with fire sleeving. Cut a 1 inch slit in the center of the fire sleeve and pass the transducer connector and cable through it. Seal with high temperature silicone RTV sealant.
The placard “Do not rely on fuel flow instrument to determine fuel levels in tanks” must be mounted on the aircraft instrument panel near the EGT-701. If the aircraft is equipped with a primary fuel flow instrument, the following placard must be mounted on the aircraft instrument panel near the EGT-701 “Refer to original fuel flow
instrumentation for primary information.”
11) WIRING (12 / 24 volt)
The EGT-701 automatically accommodates both 14 and 28 volt electrical systems. Connect the power lead (red) to a separate 5 amp circuit breaker (or 2 amp slow blow in-line fuse) connected to the avionics power buss. The avionics master switch will then be used to turn off the instrument during engine start-up. The EDM-700 has a 10-second warm-up. If the panel lacks an avionics master switch we recommend that one be installed or a circuit breaker switch be provided to turn off the EGT-701 during engine start-up. If the voltage fall below 9.8 vdc the instrument will turn off automatically. The Instrument should be grounded at the engine. No connection to the aircraft dimmer system is required because the instrument dims automatically with reductions in ambient light.
12) EGT and CHT Probe Wiring
The EGT-701 is supplied with special Teflon insulated Chromel Alumel factory assembled wiring harness configured for the correct number of cylinders. The wire harness is marked E-1= EGT-1, C-1= CHT-1, etc. TIT is marked “T”,
Oil I = “O” and OAT = “A”. For retrofits of the EGT-100 SCANNER or bar graph instruments, where only the indicators are being exchanged, the old harness wires need to be pinned with AMP P/N 665049 and fitted into AMP
D-SUB connector P/N 205207-1 with hood per drawing 300701 fig-6 or connected directly via an adapter connector.
NOTE: Unlike most other EGT & CHT installations the probe wire length is not critical and should be trimmed to any length as required for a clean installation.
The Temperature probes must be wired with the correct polarity. Each wire is marked with the cylinder number. The
EGT and CHT probes connect to the temperature indicator with yellow jacket Teflon Chromel Alumel wire supplied.
Strip the wires according to drawing 5057 and terminate with the crimp-on ring terminals provided. Verify the quality of each crimp with a sharp pull on the wire. The terminal should be almost impossible to pull off when crimped correctly.
With in a few inches of the instrument terminal strip a connector may be installed.
NOTE: The ring terminals may be crimped with a “service type” tool, however AMP part number 48518 tool is recommended. Be sure to test each crimp by pulling on the wire to assure it will not come out.
The most common installation problems are poor quality terminations.
The EGT-701 must be grounded to the engine block, not at a ground point under the instrument panel. No connection to the aircraft dimmer system is required or permitted because the instrument dims automatically with reductions in ambient light.
Install the data port connector in the instrument panel. This is the 2.5 mm ID, 5.5 mm OD on the twisted white and black wires on J1. See Installing the Instrument section earlier in this manual.
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 10 of 30
+12/24 avionic bus
(alarm wire not supplied)
Alarm lamp or enunciator
(customer supplied option)
FF
COM
EGT
EGT
ALL
FF panel mounted switch
11
9
4
3
2
1
8
7
6
5
RS-232 input to EDM-700
WHT
BLK
RED
Cut red lead if transducer is also connected to another fuel flow instrument
1 fuel flow option connector
WHT
BLK
RED
OUT
RS-232 output from
EDM-700
GPS output
GPS input
(some KLN series only)
GPS
IN
Fuel Flow Transducer
FloScan 201 -A, -B, -C, or 231
Before you begin, note that the most common cause of probe problems is poor terminal crimps.
When cutting each pair of leads in the wiring harness to the proper length to connect to the probes, leave enough slack in the harness so that probes from adjacent cylinders may be interchanged if necessary for trouble-shooting and servicing. Thermocouple wire length is not critical and should be trimmed to any length as required for a clean installation.
The Temperature probes must be wired with the correct polarity. Each wire is marked with the cylinder number. The
EGT and CHT probes connect to the temperature indicator with yellow jacket Teflon Chromel Alumel wire supplied.
Strip the wires as shown below, observing color codes.
Important: fold back the wire double before crimping terminals.
2 1/4" yellow
Fold back wire
Thermocouple wire harness
double before red crimping terminals
1/4" 1 1/2"
Terminate each wire with a crimp-on ring terminal, provided. The ring terminals may be crimped with a “service-type” tool, however AMP part number 48518 crimp tool is recommended. Verify the quality of each crimp with a sharp tug on the wire. The terminal should be impossible to pull off when crimped correctly. ring terminal shrink tubing shrink tubing
Place a ¼ x 4 inch sleeve over each pair of wires in the harness. Connect the harness ring terminal to the probe ring terminal using the supplied number 4 screws and nuts, placing the star washer between the ring terminals, not against the nut. to instrument
Important: place star waster between two ring terminals and tighten nut and bolt as necessary to probe
Slide the sleeve over the joint and secure with three tie-wraps.
1/4 x 4" sleeve tie-wrap 3 places
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 11 of 30
13) ROUTING THE WIRING HARNESS
Route the wires from the probes and sensors through the firewall using fireproof rubber grommets and flame retarding silicone. Use an existing hole if possible. Following the existing wiring harness and connect to the indicator marking each lead with the cylinder number. All wires must be routed away from high temperature areas (exhaust stacks, turbochargers, etc.). Secure Probe leads to a convenient location on the engine approximately 8 to 12 inches from the probe, being sure there is sufficient slack to absorb engine torque. It is essential in routing the probe wire that this wire not be allowed to touch metal parts of the airframe or engine since abrasion will destroy this high temperature wire.
Connect the JPI RPM sensor to the wiring harness using the 3-pin connector supplied.
Secure thermocouple wires along the route to the indicator. Secure wire using original clamps, tie wrap if possible.
CAUTION: Be sure the wiring does not obstruct the controls under the panel.
The probe wires must not be tied in with ignition, alternator or twin engine cabin heater ignition wires because of potential interference with temperature readings.
Temperature probe wiring harness is made of Chromel-Alumel alloy wire (yellow) that must not be substituted or
extended with normal copper wire. The power and ground wire are normal copper. Leads may be spliced with additional Chromel-Alumel wire using copper butt splices.
When the installation is complete all wires should be secured using ties and carefully checked for interference, rubbing or chaffing with flight control cables or other moving parts.
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 12 of 30
14) Manifold Pressure (MP) Sensor
Install a T-fitting (not supplied) in the aircraft’s MP gage line in the cockpit near the MP gage. Install the JPI MAP sensor
P/N 604010 on the T-fitting. Connect the JPI MP sensor to the wiring harness using the 4-pin connector supplied. The
MAP sensor uses a 1/8 NPT fitting. Note: this is eligible for installation on all 4 & 6 cylinder engines only. There are no alarm limits.
MP Sensor connector
MP gage from engine T-fitting
Manifold Pressure Calibration
The manifold pressure must be calibrated to the ambient air pressure. Enter the current ambient barometric pressure. The engine must not be running. This setting is not the same as the altimeter setting that you receive from ATIS or unicom. It will vary with field elevation. Use the chart below to calculate the MP FACTOR. Multiply this MP FACTOR by the altimeter setting that you receive from ATIS or unicom. For example if the field elevation is 1700 ft and the altimeter setting is 30.1, the MP FACTOR is
0.9400 from the table. Multiply 30.1 x 0.9400 to get the ambient MP of 28.29.
Field Elev MP FACTOR
-500 1.0182
1300 0.9539
1400 0.9504
3200
3300
0.8896
0.8863
5100
5200
0.8289
0.8258
-400 1.0145
-300 1.0109
-200 1.0073
-100 1.0036
0 1.0000
100 0.9964
200 0.9928
300 0.9892
1500 0.9469
1600 0.9435
1700 0.9400
1800 0.9366
1900 0.9332
2000 0.9298
2100 0.9264
2200 0.9230
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300
0.8830
0.8798
0.8765
0.8733
0.8700
0.8668
0.8636
0.8604
0.8572
0.8540
5300
5400
5500
5600
5700
5800
5900
6000
400 0.9856
500 0.9821
600 0.9785
700 0.9750
800 0.9714
900 0.9679
1000 0.9644
1100 0.9609
1200 0.9574
2300 0.9196
2400 0.9162
2500 0.9129
2600 0.9095
2700 0.9062
2800 0.9028
2900 0.8995
3000 0.8962
3100 0.8929
4400
4500
4600
4700
4800
4900
5000
0.8508
0.8477
0.8445
0.8414
0.8382
0.8351
0.8320
6100
6200
6300
6400
6500
6600
6700
0.8227
0.8196
0.8165
0.8135
0.8104
0.8074
0.8043
0.8013
0.7983
0.7953
0.7923
0.7893
0.7863
0.7833
0.7804
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 13 of 30
15) RPM Sensor installation
There are four types of magnetos commonly in use. You must have the correct RPM sensor for the magneto installed in the aircraft. The following part numbers apply: Slick – pressurized 4000, -6000 series use JPI P/N 420809. For the
Bendix pressurized -1200 series use P/N 420807. Dual magnetos use JPI PN 420808. For the Bendix -20 series and
Slick 600 use JPI P/N 420806. Mount the sensor as shown in the appropriate diagram below. Note: this is eligible for installation on all 4 & 6 cylinder engines only.
Bendix Magnetos Slick Magnetos
Bendix -20, -21, -200, 1200 series non-pressurized
JPI 420815-2
P
TO position limit
Connector to harness
Mount sensor side of bracket towards magneto body, positioned over the magnet armature position limit
Connector to harness
Alternate bracket locations
Bendix 1200 series pressurized
JPI 420807
Mount sensor side of bracket towards magneto body
Bendix Dual Magneto
JPI PN 420808 non-pressurized
Alternate bracket location Connector to harness
Vent plug
Spacer ring
Sensor ring bracket
Magneto body
Slick 6000, 4000 series pressurized
JPI 420809
rev Dec 2010
Connector to harness
Slick 6000, 4000 series non-pressurized
JPI 420815-1
Mount sensor side of bracket towards magneto body
Sensor ring munted under vent plug.
Stem at right angles to magneto center line
Sensor must be over moving magnet armature
Remove this screw to mount sensor bracket
Slick 600 series
JPI PN 420806 non-pressurized
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 14 of 30
16) DESCRIPTION / OPERATING INSTRUCTIONS
The EGT-701 temperature indicator displays temperature digitally and in analog format. The EGT as displayed is based on probes located near the exhaust outlet for each cylinder and the TIT probe, if installed, is adjacent to the turbo charger. These probes are not necessarily collocated with the primary probes therefore; EGT-701 may not indicate the same as the aircraft primary instruments. The analog display is an electronic bar graph (vertical columns, one per cylinder) of EGT & TIT temperatures presented as a percentage of 1650 o
F. Below the vertical columns the specific value for EGT and CHT are displayed digitally. The dot over the column indicates which cylinder’s digital information is presently displayed. The missing bars at the base of the columns indicate the hottest and coldest
Cylinder Head temperature trend. During Lean Find mode the leanest cylinder is displayed along with the fuel flow
(optional) at that time. Depressing the LF and STEP button simultaneously brings up the adjustable scan rate function, OAT in o
C or o
F. Depress the LF button will change the value of the rate or Oat in o
C or o
F. Exit by
Depressing STEP.
If the EGT-701 buttons are not depressed for 10 minutes the system will start scanning automatically. Depressing the
STEP button will stop the automatic scan and index through all the functions available. During constant power cruise, if the LF button is depressed for five seconds the Bargraph will level at mid scale. The leveled bars represent the peaks of each column. Each bar represents 10 o
F and now acts as an EGT & TIT trend monitor, quickly showing an increase or decrease in temperature. Depress again to return to normal; nothing else is affected. With the fuel flow option there is a three position toggle switch. The positions are: 1) EGT, digital and Bargraph display of temperatures,
2) FF, digital display of GPH, REM and USED Fuel. Temperature Bargraph remains. 3) Both, cycles through everything installed. The data port output sends RS232 serial data every 6-sec.
Options of Fuel Flow, TIT, OAT, IAT (induction air temp.), OIL, BAT (voltage) and are displayed digitally with headlines after the number, as “230 OIL” or “14 GPH”. A large value (50 +) of “CLD” indicates shock cooling usually associated with rapid descents at low power. Optional functions not installed will not display. The same acronyms are incorporated in the TFT flat panel display.
RPM 2700
EGT 1340 F switc
CH 376 F
EDM-800 Plasma display
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 15 of 30
EDM-830 TFT Flat panel display
Portrait
switc
EDM-830 TFT Flat panel display
Landscape
switc
EDM-830 system mounts in a 3.125 inch instrument panel hole in either a portrait or landscape position depending on panel hole location.
By holding the Step button (white) for approx. 10 seconds and arrow will appear on the display showing which way is up. Use the LF button to index the arrow. When the proper position is achieved, press the step button and the system will reboot in the direction chosen.
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 16 of 30
17)Installation Record
The indicator and probes FAA TSO approved, as a temperature indicator under TSO-C43b. Record the installation of the EGT-701 per STC# SA 2586NM. Make an appropriate entry in the aircraft log book. FAA form 337 may be required.
18)Operation
Airplane flight manual limitations based on primary instrument indication take precedence over those of the EGT-701.
CAUTION: Comply with manufacturer’s airplane/rotorcraft flight manual leaning procedure. Do not exceed
applicable engine or aircraft limitations.
CAUTION
Comply with manufacturer’s Airplane/Rotor craft
Flight Manual leaning procedure.
Do not exceed applicable engine or aircraft limitations.
After establishing desired cruise power depress the LF button to activate the Lean Find Mode. As the mixture is leaned, the column display on the EGT-701 for one cylinder will begin blinking; indicating the exhaust gas temperature for that cylinder has peaked. Continue with the leaning procedure as recommended by the aircraft manufacturer while monitoring the primary engine instruments and the EGT-701 display. Once the leaning procedure has been completed, depress the Step button briefly to exit the Lean Find Mode and enter the Monitor Mode.
ENGINE OPERATION: Operate and lean the engine in accordance with the manufacturers’ recommendations for different power settings. Lycoming recommends running peak EGT only at 75% power or less. Continental recommends running peak EGT at 65% power or less.
19) EGT-701 SPECIFICATIONS and LIMITATIONS
CLD (Rate of change of CHT)
DIF (Maximum EGT differential)
EGT (Exhaust Gas Temp.,K ,Max. limit 2500 o
F)
CHT (Cylinder Head Temp., J/K Max. limit 600 o
TIT (Turbine Inlet Temperature, K, Max. limit 2500 o
OIL (Oil temperature, K, Max. limit 600 o
OAT (Outside Air Temp., K, Limit -40 to 300 o
F)
IAT (Induction Air Temp., K, Max. Limit 600 o
F.)
1650 o o o
F
F
F
230/90 o
-60
500 o
/minute o
F
F
LFM (Lean Find Mode, detects first EGT peak)
BAT (Voltage, 0 to 40 volts.) Not FAA Approved under TSO-C43b 15.5/11.0 or 31.0/22.0 Hi/Lo
RPM Tested under TSO-C43b (Does not comply with TSO-C49a)
MAP Tested under TSO-C43b ( Does not comply with TSO-C45)
The conditions and test required for TSO approval of this article are minimum performance standards. It is the responsibility of those desiring to install this article either on or within a specific type or class of aircraft to determine that the aircraft installation conditions are within the TSO standards.
An alarm causes the digital function to flash when the particular limit is exceeded. Factory set alarm limits for CHT
(450 o
F) and OIL (230 o
F) are lower than the actual aircraft limits. The values may be adjusted to suit individual preference by pressing the reset button. Other factory set alarm limits are: “BAT” Voltage 15.5/11.0 or 31.0/22.0 Hi/Lo as appropriate; “DIF” (differential Hi/Lo EGT) 500 o
F; “TIT” 1650 o
F Hi; “OIL” Lo 90 o
F; “CLD” (Rate of change of cylinder head temperature in degrees per minute) -60 degrees/minute. The pilot should be aware of the setting of each alarm for his particular aircraft. An alarm is “Canceled” by holding the step button in for 5 seconds and seeing the word “OFF”. Then, only that particular alarm is canceled. Canceled alarms will not appear again until the power
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 17 of 30
has been removed and reapplied to the EGT-701. The entire display dims automatically depending on the ambient lighting.
20) Component Parts List for EGT PN-1280, TIT PN-1200, IAT PN-1300 Probe in polybag
1 Thermocouple probe PN M-111
1 Stainless Steel Clamp Thimble
1 Stainless Steel Exhaust Seal Washer
1 Stainless Steel Screw Type Clamp
2 Ring Terminals
2 Screws and nuts 6-32 X 1/4
1Fiberglass tube 1/2” X 4”
21) Component Parts list for CHT probe PN 1260
1 Bayonet Probe Spring loaded PN-5050
1 Or Gasket thermocouple probe PN M-113
2 Ring Terminals
2 Screws and Nuts 6-32 X 1/4”
1 Fiberglass tube 1/2” X 4”
22) Components Parts list for OIL probe PN 1240
1 P/N 400505 –C or –L, OIL probe
2 Ring Terminals
2 Screws and Nuts 6-32 X 1/4”
1 Fiberglass tube 1/2” X 4”
22) Components Parts list for OIL pressure PN 306018
1 P/N 306018 OIL pressure transducer
2 Ring Terminals
23) Components Parts list for OAT probe PN 1220
1 P/N 400509, OAT probe
2 Ring Terminals
2 Screws and Nuts 6-32 X1/4”
1 Fiberglass tube 1/2” X 4”
24) Components Parts list for Manifold pressure sensor probe P/N 604010
1 P/N 604010, Manifold pressure sensor with 1/8 NAP termination.
25) Components Parts list for RPM sensor P/N depends on Magneto make and model.
1) Bendix magneto series 20,21………………….…P/N 420806
2) Bendix magneto series 1200,………………..…...P/N 420807
3) Bendix magneto Plug Std and Dual ……………...P/N 420815-1
4) Slick magneto series 4000 or 6000 P/N 420809 or Plug PN 420815-2
26) Component Parts list for Single Engine, EGT and CHT
P.N. EGT-701
Temperature Indicator
-4C -6C -7C -8C -9C
1 1 1 1 1
EGT probe KIT PN 1280
CHT probe KIT PN 1260
CHT Gasket probe KIT PN 1260
Oil probe with option O KIT 1240
TIT probe with option T KIT 1200
OAT probe with option A KIT 1220
IAT probe with option I KIT 1300
4
3
1
1
1
1
1
6
5
1
1
1
1
1
7
6
1
1
1
1
1
8
7
1
1
1
1
1
Oil pressure transducer
PN 306018
1 1
MAP P/N 604010 1 1 1 1
RPM one of P/N 420806, 7, 9, 15-1,-2 1
TC Harness PN 700702
TC Harness PN 700700
TC Harness PN 700200
TC Option wire PN 700201
1
0
1
0
1
0
1
1
0
0
1
1
2
0
1
1
4
1
0
1
1
6
1
1
1
9
9
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 18 of 30
27) Weight and Balance Data
TSO C43b, Temperature Indicator EGT-701
EGT probe MM-111
CHT probe 5050
Wire P.N. WK.-24 Harness 8 ft.
RPM, MAP, and Oil pressure
30 oz. / 1.9 lbs
2.0 oz. Each / 0.125 lbs
1.5 oz. each / 0.094 lbs
14.0 oz. each / 0.88 lbs
1.5 oz each / .094 lbs
40
CHANGING THE PROGRAMMED LIMITS
Setting the K-factor (Fuel Flow Option)
You must set the K factor before using the EGT-701 with fuel flow. Note the K-factor that was engraved on the fuel flow transducer.
1. Turn on the EGT-701 and after self-test, press STEP until the instrument is cycling normally.
2. Place the select toggle switch in the FF position.
3. Start the Pilot Programming Procedure by simultaneously holding the STEP and LF buttons for five seconds. You will see the word PROGRAM for two seconds.
4. Tap the STEP button repeatedly until you see KF-SET.
5.
Hold STEP and LF for five seconds. First digit blinks: 29.00
6.
Tap or Hold LF to change flashing digit (for example): I9.00
7.
Tap STEP for next digit: I9.00
8.
Tap or Hold LF to change flashing digit: I8.00
9.
Tap STEP for next digit: I8.00
10. Repeat steps 7 and 8 for the remaining two digits.
11. Verify the K-factor that was engraved on the fuel flow transducer is now displayed.
12. Hold STEP and LF for five seconds to exit.
13. Tap STEP
Setting the Data Recording Option Parameters
(Data Recording Option only)
If you haven’t already done so, start the pilot programming procedure; simultaneously hold the STEP and LF buttons for five seconds. You will see the word PROGRAM for two seconds. To change the date, time and user id for the Data
Recording Option, tap the STEP button until the display shows DUMP? N. Next, simultaneously hold the STEP and
LF buttons for five seconds. Then set the date and time as show below
Tap STEP to
next item
MNTH
DAY
YEAR
HOUR
MIN
LF sequences
through these values
I
I2
I
3I
80
79
OO
23
OO
59
Month
Day
1980 through 2079
Comments
24 hour time. We suggest you set Zulu time.
USER ID N I2345
Tapping the step will also zero the seconds (not shown)
Hold both STEP and LF buttons simultaneously until the first character flashes.
Use LF to select the first character. STEP moves to the next character.
Hold both STEP and LF to exit.
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 19 of 30
Setting the Alarm Limits
Turn on the EGT-701 and after self-test, press STEP until the instrument is cycling normally.
To start the Alarm Limit Procedure, with the EGT-701 powered up, do the following:
Hold both buttons for 5 seconds until the word
PROGRAM
Tap STEP button until the words
Hold both buttons for 5 seconds until
END Y
the words
FAC LIM
Tap the STEP button to advance to the next item in the list. Tap the LF button to select alternate values of that item. Hold the LF button to rapidly back up. Prompts listed in the first column are displayed for only two seconds.
Changing the Alarm Limits:
STEP to next LF sequences through these values item
FAC LIM
FAC? N
FAC? Y
Factory Limits.
Restore factory defaults
Description
REV X.XX
TYPE K
TYPE K
TYPE J
Firmware rev. number.
Type K or Type J CHT probes. USE THIS WITH CAUTION.*
EGT-CHT
BATTERY
EGT DIF
CHT HI
COOL CHT
TIT HI
OIL TEMP
Hold STEP and LF for five seconds to toggle
ENG F
ENG C
I0.0 H BAT
35.0 H BAT
8.5 L BAT
30.0 L BAT
30 DIF
990 DIF
90 H CHT
500 H CHT
-5 CLD
-200 CLD
650 TIT
2000 TIT
40 H OIL
500 H OIL
I0 L OIL
250 L OIL
OIL PRESS
FUEL FLW
FUEL GAL
FUEL KGSFUEL
LTR
FUEL LBS
MAIN TK
AUX TNK
MAIN =50
AUX? N
AUX? Y
LO TIME
AUX =0
MIN
=45
LO FUEL
RECRD?
REM
=I0
CARB? N
CARB? Y
RECRD? Y
RECRD? N
END Y
END N
Select F or C degrees for all engine temps.
Battery high voltage limit, set in 0.5 volt increments.
Battery low voltage limit.
EGT difference limit set in 10° increments.
CHT high limit set in 5° increments.
Cooling limit set in 5°/min. increments.
Both EGT and TIT hi limits are the same.
Oil temperature high limit, set in 5° increments.
Oil temperature low limit set in 5° increments
Oil pressure low limit
Selects the units in all parameters where fuel quantity or fuel rate is displayed
Main tank capacity, in units selected
Y - Yes - aircraft has auxiliary tanks
Auxiliary tank capacity
Alarm limit in minutes for low time in tanks
Alarm limit for low fuel quantity in tanks, in units selected
Y - Yes: carbureted engine
Data Recording Option Y-only data recording. N – Only realtime data output.
Y - Yes to exit; N - No to review list again
*CHT will read incorrectly if the wrong probe type is selected. Type K probes generally have red and yellow wires; type J probes have black and white wires.
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 20 of 30
Fuel Flow Units (Fuel Flow Option)
Selects the units in all parameters where fuel quantity or fuel rate is displayed. If you change this parameter, it does not change the numerical value of the fuel tank capacity. You must do this manually. For example if you change from Gal. to Lbs., the tank capacity will be interpreted as 50 Lbs. rather than 50 gallons; the EGT-701 will not convert 50 Gal to equivalent pounds.
Main Tank Capacity (Fuel Flow Option)
Enter the total capacity of the main tanks in the fuel flow units selected. If you have tank tabs (but no auxiliary tanks) and sometimes fill only to the tabs, set the main tank capacity to the capacity up to the tabs.
Auxiliary Tanks (Fuel Flow Option)
If you do not have auxiliary tanks or tank tabs, answer “No.” If you answer yes, you will be asked to input the capacity of the auxiliary tanks in the fuel flow units selected. If you have tank tabs and sometimes fill only to the tabs, set the auxiliary tank capacity to the difference between full tank capacity and tab capacity.
Low Time Alarm Limit (Fuel Flow Option)
Select the value of the time remaining, in minutes, that triggers the alarm. Time remaining is calculated at the current fuel flow rate.
Low Fuel Alarm Limit (Fuel Flow Option)
Select the value of the fuel remaining, in the selected fuel flow units, that triggers the alarm. Fuel remaining is calculated at the current fuel flow rate.
Carburetor? (Fuel Flow Option)
Different response filters are used depending on whether your engine is carbureted or fuel injected. The filter for a carbureted engine has a slower response time to reduce sudden fluctuations in readings.
29) Troubleshooting
a) A missing column in the display on start up indicates that the diagnostic routine has found an open wire or probe with a poor connection. The error message will indicate which channel to examine. b) A missing column in the display during flight indicates a widely varying or erroneous temperature value. The probe is deleted from the indexing to prevent false alarms. c) Start up OPEN PRB message. If one of the temperature probe circuits is open, the display indicates
OPEN PRB followed by one of these messages: EGT 1, EGT 2, EGT 3, EGT 4, EGT 5, EGT 6, EGT 7,
EGT 8, EGT 9, CHT 1, CHT 2 , CHT 3, CHT 4, CHT 5, CHT 6, CHT 7, CHT 8, CHT 9, OIL, IND, OAT,
TIT. Check the connector at the instrument and verify that a female pin is not recessed in the connector.
Check the crimps where the probe is connected to the wiring harness. d) A negative reading (- in front of the number) indicates reverse polarity on the red and yellow thermocouple wire to probe. e) Ohmmeter check. Remove the connector from the rear of the instrument and measure the resistance of the probe lead pairs. The reading should be about 10 ohms. At the connections between the probe and the wiring harness in the engine compartment, the resistance should read about 2 ohms. f) All readings varying rapidly. Verify that the Instrument is grounded at the engine block for single engine installations. If an adapter probe is being used insure that it is screwed in tightly and grounded.
Remove the factory original probe that is in the adapter and note if problem is resolved. If so an ohm ground exists between the engine and the adapter probe.
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 21 of 30
g) One CHT reads higher or lower than the others. It is most likely that this is the cylinder that has the spark plug gasket probe installed. Choose the upper or lower spark plug, the one that provides the best correlation with the other temperature probes. Due to the spark plug location, the gasket probe may read higher or lower than the factory probe. Place the probe on the plug that receives the most direct cooling air h) One cylinder seems to read erroneously. Physically swap the suspected probe with a probe from a correctly reading cylinder. If the problem moves to the correctly reading cylinder (stays in the same column on the instrument) check the crimps between the probe and the wiring harness. Check the pins on the connector that plugs into the instrument. If those check okay, then the probe should be replaced.
If the problem moves to the other probe’s column on the instrument, the temperature readings are correct and there is probably a problem with the original cylinder. i) Large EGT span. Normally aspirated (carburetor) engines at normal cruise display a “DIF” of 125 to
175 o
F spread between cylinders. Injected engines at normal cruise display a “DIF” 50 to 90 o
F spread between cylinders. All cylinders are measured by common circuitry. It is unlikely that the calibration is in error on only one channel. j) Temperature reading varies more than 500°F in one second. Check for a poor quality crimp between the probe and harness. k) All EGT or CHT readings seem too high or low or unsteady. Verify that the Instrument is grounded at the engine block for single engine installations. Use a DVM (digital voltmeter) to measure the difference between instrument ground and the engine block ground. If the difference is greater than 0.5 volts with the alternator charging, the ground to the instrument is faulty. l) All EGT and CHT readings seem too low. The instrument may be set to display engine temperatures in Celsius when you are used to seeing Fahrenheit. See Pilot’s Guide under Pilot Programming. m) OAT readings in error more than 10°, but oil and CHT readings are okay. Look for copper wire spliced in line to the OAT probe. The OAT reading can be adjusted
10°. See Pilot’s Guide under Pilot
Programming. n)
All CHTs read high (100F) EGT-701 calibrated for Gem installation “J” calibration. Change to “K” calibration using the procedure to set alarm limits described earlier.
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 22 of 30
FIG-1
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 23 of 30
Mounting bracket for the EDM-730/830
EDM-730/830 Model: Mounts in a standard 3.1/8” instrument hole. First place the mounting bracket on the instrument and tighten the clamp hex screw until you can just remove the instrument from the bracket. The Mounting bracket is then placed behind the instrument panel hole and screwed (6-32 x ½” screws) in place using the existing holes. Three screws should be used leaving one hole vacant on either side of the hex screw. Locate the hex screw in a location that you can easily get to from the rear of the panel. The body of the instrument is 3.0 inches and 2.0 inches deep less connectors.
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 24 of 30
EDM-730/830 Layout
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 25 of 30
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 26 of 30
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 27 of 30
FIG - 6
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 28 of 30
Fig 7
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 29 of 30
Fig - 9
FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103
INSTALLING THE EGT-701 SCANNER® 1/20/09
Rev-E Page 30 of 30
Instructions for Continued Airworthiness (ICA)
There are no field adjustments and or calibration requirements for the EDM-700/730 series instrument after initial installation. ICA is not required. Maintenance of nonfunctioning or malfunctioning components is limited to removal and replacement of JPI factory supplied new or repaired components as described in the troubleshooting section of the installation instructions
Advertisement
Key features
- Displays temperature digitally and in analog format
- Provides exhaust gas temperature and turbine inlet temperature (TIT) readings
- Includes fuel flow, TIT, OAT, IAT, OIL, BAT, RPM, and MAP options
- Features Lean Find Mode for precise mixture adjustment
- Offers adjustable scan rate and automatic scanning
- Allows for both 14 and 28 volt electrical systems
- Includes various alarm functions, including EGT, CHT, OIL, TIT, and voltage
- Dim automatically with reductions in ambient light
- Automatic scan and index through all available functions
- User-adjustable programmed limits for various parameters