industrial
fan heaters
the CFH range
A range of rugged, high power electronic
fan heaters designed to offer a full heating
system to larger industrial environments,
these wall mounted heaters use powerful
centrifugal blowers for a faster airflow in the
most challenging of environments.
Offered in 6kW, 9kW or 12kW, the CFH range
can be controlled individually or as a system of
heaters with the additional wall mounted digital
remote (CFCH), with cool blow, heat output and
thermostatic control available.
All models in the range can be simply linked
together using CAT 5 PC network cable, and
have multi-directional wall mounting brackets for
the ultimate in ease of installation and control.
Range features
•
•
•
•
•
•
•
•
•
•
•
Heavy duty corrosion resistant case.
Multi-directional wall mounting brackets.
Fast airflow with air-off temperatures from
30°C to 60°C.
Low voltage switch connections.
Digital heater control.
Fan over-run facility for maximum heater
efficiency.
On-board electronic control giving balanced
3 phase load at full and half heat.*
Fan and heat level control.*
7 day time and temperature control.*
Full electronic thermostat for accurate control.*
Full function system control of up to 10
heaters.*
Model CFH90
* All CFH models are controlled via the digital CFCH Controller.
Model CFH120
84
commercial & industrial heaters
DIMP-15376-New HEATBOOK-aw
1/10/06
10:12 am
Page 85
technical specifications
Construction/Finish
Corrosion resistant body with durable finish
colour matched to the CAB/DAB air curtain.
Finned/sheathed heating elements with rigid steel
outlet grille vanes to direct airflow.
Colour: White casing with black grille.
Controls
No on-board controls.
All CFH models are controlled via the CFCH
controller.
Diagram showing Air Temperature
Rise from CFH Models
Safety
Manual reset cut-out.
6kW
900m3/h
9kW
900m3/h
12kW
900m3/h
150
300
450
Positioning
INCORRECT POSITIONING
INCORRECT POSITIONING
CORRECT POSITIONING
Heaters should be positioned in relation to one
another such that there is no collision of air flows.
Main Dimensions – CFS and CFH Ranges
B
C
D
A
Installed Range – Electronic Units
Model
Output
Supply
Airflow
Throw
Noise
Level
Air-off
Temp#
Height
A
Width
B
Depth
C
Max Depth
D
Weight
CFH60
6kW
220-240V~ 1PN
380-415V~ 3PN
900m3/h
10m
55dB(A)
40°C
360mm
386mm
565mm
630mm
13.5kg
CFH90
9kW
220-240V~ 1PN
380-415V~ 3PN
900m3/h
10m
60dB(A)
55°C
360mm
386mm
565mm
630mm
14.5kg
CFH120
12kW
220-240V~ 1PN
380-415V~ 3PN
900m3/h
10m
60dB(A)
65°C
360mm
386mm
565mm
630mm
14.5kg
# Calculated at 21°C
Controls
B
A
160mm
Model
Max No. heaters
Output
Supply
Cable type
Height A
Width B
Depth
CFCH
10
Low Voltage
220-240V~ 1PN
CAT 5 NETWORK
113mm
217mm
49mm
technical specification