BASIC SERIAL COMMAND
FUNCTIONAL SPECIFICATIONS
PLC-XF70
Ver.1.00
SANYO Electric Co., Ltd
Personal Mobile Group
DI Company
Projector Business Division
PLC-XF70 Basic Serial Command Functional Specifications
Contents
1
Overview....................................................................................................................... 4
2
Serial Interface Specification...................................................................................... 4
2.1
Transfer Specification .......................................................................................... 4
2.2
Connection............................................................................................................ 4
3
Notes for Communication........................................................................................... 5
4
FUNCTIONAL Execution Command Table................................................................. 6
5
Status Read Command Table ..................................................................................... 6
6
Functional Execution Command................................................................................ 7
6.1
Format ................................................................................................................... 7
6.2
Command Pipelining............................................................................................ 7
6.3
Transfer Example.................................................................................................. 7
6.4
Operation Requirements...................................................................................... 8
6.5
POWER ON Command ......................................................................................... 8
6.6
POWER OFF Command (Immediate POWER OFF)............................................. 8
6.7
INPUT 1 Command ............................................................................................... 8
6.8
INPUT 2 Command ............................................................................................... 9
6.9
INPUT 3 Command ............................................................................................... 9
6.10
INPUT 4 Command ............................................................................................... 9
6.11
VIDEO MUTE ON Command ................................................................................ 9
6.12
VIDEO MUTE OFF Command .............................................................................. 9
6.13
REGULAR VIDEO IMAGE Command .................................................................. 9
6.14
WIDE VIDEO IMAGE Command......................................................................... 10
6.15
MENU ON Command .......................................................................................... 10
6.16
MENU OFF Command ........................................................................................ 10
6.17
DISPLAY CLEAR Command .............................................................................. 10
6.18
IMAGE Command ............................................................................................... 10
6.19
D.ZOOM + Command ......................................................................................... 10
6.20
D.ZOOM – Command.......................................................................................... 11
6.21
POINTER RIGHT Command ............................................................................... 11
6.22
POINTER LEFT Command ................................................................................. 11
6.23
POINTER UP Command ..................................................................................... 11
6.24
POINTER DOWN Command............................................................................... 11
6.25
ENTER Command............................................................................................... 11
6.26
FREEZE ON Command ...................................................................................... 12
6.27
FREEZE OFF Command..................................................................................... 12
6.28
ZOOM + Command ............................................................................................. 12
6.29
ZOOM – COMMAND............................................................................................ 12
6.30
FOCUS + Command ........................................................................................... 12
6.31
FOCUS – Command ........................................................................................... 13
2/24
PLC-XF70 Basic Serial Command Functional Specifications
7
8
6.32
LENS SHIFT UP Command ................................................................................ 13
6.33
LENS SHIFT DOWN Command.......................................................................... 13
6.34
LENS SHIFT LEFT Command ............................................................................ 13
6.35
LENS SHIFT RIGHT Command .......................................................................... 13
6.36
AUTO PC ADJ. Command.................................................................................. 13
6.37
PRESENTATION TIMER Command ................................................................... 14
6.38
KEYSTONE ↑ Command .................................................................................... 14
6.39
KEYSTONE ↓ Command .................................................................................... 14
6.40
KEYSTONE → Command................................................................................... 14
6.41
KEYSTONE ← Command................................................................................... 14
Status Read Command.............................................................................................. 15
7.1
Format ................................................................................................................. 15
7.2
Transfer Example................................................................................................ 15
7.3
Status Read Command ...................................................................................... 16
7.4
Input Mode Read Command .............................................................................. 19
7.5
Lamp Time Read Command .............................................................................. 19
7.6
Setting Read Command ..................................................................................... 19
7.7
Temp Read Command........................................................................................ 20
7.8
Lamp Mode Read Command ............................................................................. 20
7.9
PC Type Read Command ................................................................................... 20
7.10
Status 2 Read Command ................................................................................... 21
Command with Address Specification..................................................................... 22
8.1
Overview ............................................................................................................. 22
8.2
Functional Execution Command with address ................................................ 23
8.3
Status Read Command with Address ............................................................... 24
3/24
PLC-XF70 Basic Serial Command Functional Specifications
1
Overview
・ This specification defines projector control commands for the XF70.
・ The projector control commands are designed to remote-control a projector through RS-232C
from a computer.
・ Refer to [8. Command with Address Specification] when using commands with address.
2
Serial Interface Specification
2.1
Transfer Specification
Items
1)
Specification
Synchronous system
Asynchronous
Transmission Speed
9600 / 19200
Data Length
8 bits
Parity
None
Stop Bit
1
Flow Control
None
Transmission speed: initial setting value is 19200.
2) Transmission speed can be changed in Service Mode.
2.2
Connection
Dedicated serial cables that come with a projector must be used for the connection to a
computer and the projector.
PC
Projector
COM 1
Serial Port IN
(D-Sub 9Pin)
(D-Sub 9Pin)
Connect COM port of the computer to SERIAL PORT IN of the projector.
COM Port (COM1 or COM2) of a computer is specified by control software of the computer.
4/24
PLC-XF70 Basic Serial Command Functional Specifications
3
Notes for Communication
・
The projector command is defined one command per line that starts “C” and ends carriage return
(0x0D).
・
When the projector receives the carriage return, it starts decoding.
・
There are two types of command, Functional Execution Commands and Status Read Commands.
Example of Functional Execution Command: “C05” [CR]
Example of Status Read Command: “CR0” [CR]
・
It clears the information of buffer in the following cases.
- When the projector receives LF (0x0A) or EOF (0x1A9).
- When it takes more than one second to receive a single command.
(Until receiving the carriage return after the reception of the first data.)
・
When pipelining control commands, allow interval time as below after the reception of response,.
1) [ZOOM UP/DOWN] [FOCUS UP/DOWN] [LENS SHIF UP/DOWN/LEFT/
RIGHT] commands…100ms
2) Other commands…500ms
・
When pipelining Status Read command, allow at least 500ms of interval time after the response.
・
Do not issue any command before receiving the response except the case that there is no response
for 5 seconds.
・
It takes about 7 seconds for internal initialization after plugging in AC. During this time, it cannot
process command. Do not issue any commands.
・
For 7 seconds after starting POWER ON in the status of STANDBY, the projector returns
“Acceptable” response, but it does not carry out the command.
Status Read commands are
carried out in 500 ms after the “Acceptable” response is returned.
・
About the behavior during Count Down and Cooling Down operation; in the period of the Count
Down operation after Power ON or Cooling Down after Power OFF, “Acceptable” response is
returned, but the command is not carried out except for Status Read command.
・
About the behavior during switching inputs; it takes 5 seconds to switch inputs after receiving the
command. During this period, even if another command is received, it is not carried out although
returning “Acceptable” response. However, Status Read commands are carried out in 500 ms after
the “Acceptable” response is returned.
・
The length of the returned value for Status Read command in successful operation depends on the
command.
・
The characters for commands must be in uppercase (A - Z). Those in lowercase can not be used
5/24
PLC-XF70 Basic Serial Command Functional Specifications
4
Functional Execution Command Table
Command
C00
C01
5
Command
Item
POWER ON
POWER OFF
(Immediate POWER OFF)
Item
C43
FREEZE ON
C44
FREEZE OFF
C05
INPUT 1
C46
ZOOM -
C06
INPUT 2
C47
ZOOM +
C07
INPUT 3
C4A
FOUCS -
C08
INPUT 4
C4B
FOUCS +
C0D
VIDEO MUTE ON
C5D
LENS SHIFT UP
C0E
VIDEO MUTE OFF
C5E
LENS SHIFT DOWN
C0F
REGULAR VIDEO IMAGE (4:3)
C5F
LENS SHIFT LEFT
C10
WIDE VIDEO IMAGE (16:9)
C60
LENS SHIFT RIGHT
C1C
MENU ON
C89
AUTO PC ADJ.
C1D
MENU OFF
C8A
PRESENTATION TIMER
C1E
DISPLAY CLEAR
C8E
KEYSTONE ↑
C27
IMAGE
C8F
KEYSTONE ↓
C30
D.ZOOM +
C90
KEYSTONE →
C31
D.ZOOM -
C91
KEYSTONE ←
C3A
POINTER RIGHT
C3B
POINTER LEFT
C3C
POINITER UP
C3D
POINITER DOWN
C3F
ENTER
Status Read Command Table
Command
Item
CR0
Status Read
CR1
Input Mode Read
CR3
Lamp Time Read
CR4
Setting Read
CR6
Temp. Read
CR7
Lamp Mode Read
CR9
PC Type Read
CRA
Status 2 Read
6/24
PLC-XF70 Basic Serial Command Functional Specifications
6
Functional Execution Command
6.1
Format
1) PC issues a command in the format below:
“C” Command [CR]
Command: two characters (Refer to Functional Execution Command Table)
2) A projector decodes the received data and returns the result after getting ready to receive
another command.
[ACK] [CR]: (0x06, 0x0D) When the projector has received Functional Execution
Commands.
“?” [CR]: When the received data cannot be decoded
6.2
Command Pipelining
Functions which need command pipelining follow the rule below.
- Sender system issues any command every 100ms.
- When receiving the applicable command, the function is executed for 120ms from the
moment.
- When receiving the same command in succession within 120ms, the function is executed
for another 120ms from the moment.
- When there is no incoming command after 120ms, the execution of pipelining is stopped.
- When the projector receives incoming other command within 120ms, the execution of
pipelining is stopped.
6.3
Transfer Example
Changing input to INPUT3 with Basic Command.
Command
PC → Projector
“C”
“0”
“7”
CR
Projector → PC
ACK
CR
Processing
(a few ms – 1s)
7/24
PLC-XF70 Basic Serial Command Functional Specifications
6.4
Operation Requirements
When the projector is in the status below, Functional Execution Commands are limited.
(Status Read Commands are available in following status)
Projector Status
Available Functional Execution Commands
In Standby mode
C00: POWER ON
Count Down in process
C00: POWER ON (Countdown is terminated)
Cooling Down in process
NONE (No Execution)
Cooling Down in process due to abnormal
temperature
NONE (No Execution)
In Abnormal Temperature
NONE (No Execution)
In Abnormal Power Status
NONE (No Execution)
On switching modes
NONE (No Execution)
Power Saving Cooling Down in process
NONE (No Execution)
In Power Saving status
C00: POWER ON
C01: POWER OFF
Note) In the above status, it returns [ACK] [CR] even if the projector receives other commands,
6.5
POWER ON Command
COMMAND
Detail
Response
6.6
Power ON
When already Power is ON, no operation starts.
When sending this command during Count Down in process, Count Down
process is terminated.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
POWER OFF Command (Immediate POWER OFF)
COMMAND
Detail
Response
6.7
“C00” [CR]
“C01” [CR]
Power OFF (Standby)
When Power is turned OFF with ON/STAND-BY button of the projector and
remote control, “Power OFF” is displayed. In contrast, this command executes
immediately Power OFF.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
INPUT 1 Command
COMMAND
Detail
Response
“C05” [CR]
Select Input 1
Note) When there is no board inserted to Input 1, it is not executed.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
8/24
PLC-XF70 Basic Serial Command Functional Specifications
6.8
INPUT 2 Command
COMMAND
Detail
Response
6.9
Detail
Response
Detail
Response
Detail
Response
Unacceptable
“?” [CR]
“C07” [CR]
Select Input 3
Note) When there is no board inserted to Input 3, it is not executed.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
“C08” [CR]
Select Input 4
Note) When there is no board inserted to Input 4, it is not executed.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
“C0D” [CR]
Video Mute ON
This command works the same way as “SHUTTER” button of the remote control,
but it works only for Shutter Open, not for Shutter Close.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
VIDEO MUTE OFF Command
COMMAND
Detail
Response
6.13
[ACK] [CR]
VIDEO MUTE ON Command
COMMAND
6.12
Acceptable
INPUT 4 Command
COMMAND
6.11
Select Input 2
Note) When there is no board inserted to Input 2, it is not executed.
INPUT 3 Command
COMMAND
6.10
“C06” [CR]
“C0E” [CR]
Video Mute OFF
This command works the same way as “SHUTTER” button of remote control, but
it works only for Shutter Close, not for Shutter Open.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
REGULAR VIDEO IMAGE Command
COMMAND
Detail
Response
“C0F” [CR]
Set screen size to Regular(4:3)
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
9/24
PLC-XF70 Basic Serial Command Functional Specifications
6.14
WIDE VIDEO IMAGE Command
COMMAND
Detail
Response
“C10” [CR]
Set screen size to Wide (19:6)
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
6.15 MENU ON Command
COMMAND
Detail
Response
6.16
Display Menu of On Screen Display
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
MENU OFF Command
COMMAND
Detail
Response
6.17
“C1C” [CR]
“C1D” [CR]
Clear Menu of On Screen Display
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
DISPLAY CLEAR Command
COMMAND
Detail
Response
“C1E” [CR]
Clear On Screen Display
Clear On Screen Display unconditionally.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
6.18 IMAGE Command
COMMAND
Detail
Response
6.19
“C27” [CR]
Switch Image setting.
In the case of the projector and remote control possessing an "IMAGE" button,
this command work as an "IMAGE" function.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
D.ZOOM + Command
COMMAND
Detail
Response
“C30” [CR]
Enter Digital Zoom mode and expand image size.
This command works the same way as “D.zoom▲” button of remote control.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
10/24
PLC-XF70 Basic Serial Command Functional Specifications
6.20
D.ZOOM – Command
COMMAND
Detail
Response
6.21
Detail
Response
Detail
Response
Detail
Response
Unacceptable
“?” [CR]
“C3A” [CR]
Move Pointer of On Screen Display Menu to the right
This command works the same way as “►” button of the projector and remote
control.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
“C3B” [CR]
Move Pointer of On Screen Display Menu to the left
This command works the same way as “◄” button of the projector and remote
control.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
“C3C” [CR]
Move Pointer of On Screen Display Menu upward.
This command works the same way as “▲” button of the projector and remote
control.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
POINTER DOWN Command
COMMAND
Detail
Response
6.25
[ACK] [CR]
POINTER UP Command
COMMAND
6.24
Acceptable
POINTER LEFT Command
COMMAND
6.23
Enter Digital Zoom mode and compress image size.
This command works the same way as “D.zoom▼” button of remote control.
POINTER RIGHT Command
COMMAND
6.22
“C31” [CR]
“C3D” [CR]
Move Pointer of On Screen Display Menu downward.
This command works the same way as “▼” button of the projector and remote
control.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
ENTER Command
COMMAND
Detail
Response
“C3F” [CR]
This command works the same way as “SELECT” button of the projector and
remote control.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
11/24
PLC-XF70 Basic Serial Command Functional Specifications
6.26
FREEZE ON Command
COMMAND
Detail
Response
6.27
Detail
Response
Detail
Response
[ACK] [CR]
Unacceptable
“?” [CR]
“C44” [CR]
Cancel Freeze function
This command works the same way as “FREEZE” button of the remote control,
but it works only for turning off, not for turning on Freeze.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
“C47” [CR]
Make screen image larger
This command works the same way as “ZOOM▲” button of the projector and
remote control.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
ZOOM – COMMAND
COMMAND
Detail
Response
6.30
Acceptable
ZOOM + Command
COMMAND
6.29
Freeze on-screen picture
This command works the same way as “FREEZE” button of the remote control,
but it works only for turning on, not for turning off Freeze.
FREEZE OFF Command
COMMAND
6.28
“C43” [CR]
“C46” [CR]
Make screen image smaller
This command works the same as “ZOOM ▼” button of the projector and remote
control.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
FOCUS + Command
COMMAND
Detail
Response
“C4B” [CR]
Adjust focus of screen image (sharp and clear) with a long-focal-length (∽)
(The lens direction is backward)
This command works the same way as “FOCUS ▲” button of the projector and
remote control.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
12/24
PLC-XF70 Basic Serial Command Functional Specifications
6.31
FOCUS – Command
COMMAND
Detail
Response
“C4A” [CR]
Adjust focus of screen image (sharp and clear) with a short-focal-length
(The lens direction is forward)
This command works the same way as “FOCUS ▼” button of the projector and
remote control.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
6.32 LENS SHIFT UP Command
COMMAND
Detail
Response
6.33
“C5D” [CR]
Move screen image upward
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
LENS SHIFT DOWN Command
COMMAND
Detail
Response
“C5E” [CR]
Move screen image downward
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
6.34 LENS SHIFT LEFT Command
COMMAND
Detail
Response
6.35
Move screen image to the left.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
LENS SHIFT RIGHT Command
COMMAND
Detail
Response
6.36
“C5F” [CR]
“C60” [CR]
Move screen image to the right.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
AUTO PC ADJ. Command
COMMAND
Detail
Response
“C89” [CR]
Execute Auto PC Adj. function
This command works the same way as “AUTO” button of the projector and
remote control.
When this command is received during Auto PC Adj. operation, the operation is
stopped.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
13/24
PLC-XF70 Basic Serial Command Functional Specifications
6.37
PRESENTATION TIMER Command
COMMAND
Detail
Response
6.38
Detail
Response
Detail
Response
[ACK] [CR]
Unacceptable
“?” [CR]
“C8E” [CR]
Correct keystone distortion by reducing upper part of image.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
“C8F” [CR]
Correct keystone distortion by reducing lower part of image.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
KEYSTONE → Command
COMMAND
Detail
Response
6.41
Acceptable
KEYSTONE ↓ Command
COMMAND
6.40
Start timer to count time for presentation
This command works the same way as “P-TIMER” button of the remote control.
KEYSTONE ↑ Command
COMMAND
6.39
“C8A” [CR]
“C90” [CR]
Correct keystone distortion by reducing right part of image.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
KEYSTONE ← Command
COMMAND
Detail
Response
“C91” [CR]
Correct keystone distortion by reducing left part of image.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
14/24
PLC-XF70 Basic Serial Command Functional Specifications
7
Status Read Command
7.1
Format
1)
PC issues a command in the format below:
“CR” Command [CR]
Command: Single character (Refer to Status Read Command Table)
2)
When a projector receives the appropriate command, it returns the required information as
a data string.
Required Data [CR]
Required Data: String (Refer to Status Read Command Table)
3)
7.2
When the received data cannot be decoded, the projector returns “?” [CR].
Transfer Example
Get the selected input for the projector by Basic Commands.
Command (issue the current input read command)
PC → Projector
“C”
“R”
“1”
CR
Projector → PC
“1”
CR
Response
(A few ms - 1s)
(Indicates Input 1 is selected)
15/24
PLC-XF70 Basic Serial Command Functional Specifications
7.3
Status Read Command
COMMAND
Detail
“CR0” [CR]
Get the projector status
Acceptable
Response
%1
“%1” [CR]
“00” = Power ON
“80” = Standby
“40” = Countdown in process
“20” = Cooling Down in process
“10” = Power Failure
“28” = Cooling Down due to Abnormal Temperature in process
“02” = Cannot accept RS-232C Command
“24” = Power Management Cooling Down in process
“04” = Power Management status
“21” = Cooling Down in process after Off due to lamp failure
“81” = Standby after Cooling Down due to lamp failure
“88” = Standby after Cooling Down due to
Abnormal Temperature
“2C” = Cooling Down in process after Power Off due to
Shutter management
“8C” = Standby after Cooling Down due to
Shutter management
Unacceptable
“?” [CR]
【Details for Response】
・ “00” [CR]
Status: Power ON
Normal image is on screen.
・ “80” [CR]
Status: Standby
When the status is Standby, Status Read Commands are always accepted, but Functional
Execution Commands are not accepted except POWER ON Command.
・ “40” [CR]
Status: Countdown in process
When “Display” in Setting menu is set to ON, execution of Power ON operation brings into
Countdown status.
When “Display” in Setting menu is set to OFF, the status jumps to Power ON without
Countdown operation.
・ “20” [CR]
Status: Cooling Down in process
Execution of POWER OFF Command (“C01” [CR]) in power on status brings into Cooling
Down status.
This status automatically moves to Standby when the lamp is turned off and the fan spin
finishes after about 90 seconds (the time of spinning fan depends on models).
During this time, Functional Execution Commands are not accepted.
16/24
PLC-XF70 Basic Serial Command Functional Specifications
・
“10” [CR]
Status: Power Failure
When the power supply voltage inside the projector reaches abnormal level, the status
automatically moves to Power OFF.
※
Abnormal power supply voltage includes;
-
Filter abnormal status
-
Shutter abnormal status
The projector returns “10” [CR], which indicates the status moves to Power OFF due to
power failure. Fan also stops.
・ “28” [CR]
Status: Cooling Down due to Abnormal Temperature in process.
When the internal temperature rises abnormally, it automatically starts Cooling Down
process. Response value for this status is “28” [CR].
Even if the temperature comes down during this process, the given Cooling Down process
is executed and it moves to Standby mode.
・ “02” [CR]
Status: RS-232C Commands cannot be accepted
When receiving this response, re-send Status Read Command.
・ “24” [CR]
Status: Power Management Cooling Down in process.
When Power Management function in setting menu is set to ON, continuous 5 minutes of
no signal status leads to turning off lamps and starting Cooling Down operation (Green
LED on the projector body is turned off).
During this period, any Functional Execution Command cannot be accepted.
The Power Management Cooling Down operation continues about 90 seconds, then the
status moves to Power Management.
Status: No signal
Response:
Power Management Cooling Down
“00”
“24”
5 minutes of no signal status
Power Management
“04”
After about 90 sec.
・ “04” [CR]
Status: Power Management
This indicates it has moved to Power Management status according to the setting of Power
Management function in Setting menu.
17/24
PLC-XF70 Basic Serial Command Functional Specifications
・ “21” [CR]
Status: Cooling Down in process after turned off due to lamp failure
When a projector is turned off because of lamp failure, it automatically starts Cooling Down
operation, in which the projector returns “21” [CR].
・ “81” [CR]
Status: Standby after Cooling Down due to lamp failure
This value is returned when Cooling Down operation due to lamp failure has been
completed and the status has been moved to Standby. The status is kept until the next
operation starts.
・ “88” [CR]
Status: Standby after Cooling Down due to Abnormal Temperature
This value is returned when Cooling Down operation due to Abnormal Temperature has
been completed and the status has been moved to Standby. The status is kept until the
next operation starts.
・ “2C” [CR]
Status: Cooling Down in process due to Shutter management function
This indicates it has moved to Cooling down status according to the setting of Shutter
Management function in setting menu. During this time, Functional Execution Commands
are not accepted.
・ “88” [CR]
Status: Standby after Cooling Down due to Shutter management function
This value is returned when Cooling Down operation due to Shutter management has been
completed and the status has been moved to Standby. The status is kept until the next
operation starts. When projector is turned on again, it cancels the last status and starts
normal operation.
18/24
PLC-XF70 Basic Serial Command Functional Specifications
7.4
Input Mode Read Command
COMMAND
Detail
“CR1” [CR]
Get currently selected SLOT
Acceptable
Response
%1
Unacceptable
7.5
“1” = Input 1 is selected
“2” = Input 2 is selected
“3” = Input 3 is selected
“4” = Input 4 is selected
(In the case SLOT method, SLOT 1~4 is selected.)
“?” [CR]
Lamp Time Read Command
COMMAND
Detail
“CR3” [CR]
Get total lamp running hours
Acceptable
Response
%1, %2
Unacceptable
7.6
“%1” [CR]
“%1_%2” [CR]
Each lamp data follows in sequence with one space between
each of them.
%1 = lamp No.1
%2 = lamp No.2
ex; “0410_0410_0410_0410” [CR]
▪▪▪▪ → Lamp No.1 = 410 Hours
Lamp No.2 = 410 Hours
Note;
-each data shall be 4 digits.
-“9999” is returned for 10000 hours or more.
“?” [CR]
Setting Read Command
COMMAND
Detail
“CR4” [CR]
Get screen setting status of Ceiling/Rear.
Acceptable
Response
%1
Unacceptable
“%1” [CR]
“11” [CR] = Normal Screen Setting
“10” [CR] = Picture is top/bottom reversed
(Status: Rear & Ceiling ON)
“01” [CR] = Picture is left/right reversed (Status: Rear ON)
“00” [CR] = Picture is top/bottom and left/right reversed
(Status: Ceiling ON)
“?” [CR]
19/24
PLC-XF70 Basic Serial Command Functional Specifications
7.7
Temp Read Command
COMMAND
Detail
“CR6” [CR]
Get the temperature information inside projector
With more than one temperature sensors installed in the projector, it is possible
to get all temperatures at once.
Acceptable
“%1_%2_%3” [CR]
%1 = temperature at Sensor 1
%2 = temperature at Sensor 2
%3 = temperature at Sensor 3
Response
%1
%2
Unacceptable
7.8
Temperature data is expressed as “00.0”.
When the temperature goes under 0, the first character is “-” like
“-05.5” [CR].
When no temperature data returns due to hardware problems
the first character is “E” like” E00.0” [CR].
With more than one temperature sensors installed, the projector
returns the values in series.
Ex) “_31.5_ _35.2_ _33.4” [CR]
Each sensor data follows in sequence with one space between
each of them.
“?” [CR]
Lamp Mode Read Command
COMMAND
Detail
“CR7” [CR]
Get current Lamp Mode in the multiple-lamp projector.
When there is any fail lamp, also can get the information about.
Acceptable
“%1” [CR]
ex: ”0F”[CR]
The first digit indicates Lamp Mode.
0 = 2lamp Mode
1 = 1lamp Mode (Lamp No.1 used)
2 = 1lamp Mode (Lamp No.2 used)
Response
%1
Unacceptable
7.9
The second digit indicates if the lamp is ON or OFF.
Data is shown as “0-9” and “A-F”, which is described in 4-bit
data. Assign each bit for each lamp data.
ex: 0 = ALL is OFF
1 = No.1 is ON, the other is OFF
2 = No.2 is ON, the other is OFF
3 = ALL is ON
“?” [CR]
PC Type Read Command
COMMAND
Detail
“CR9” [CR]
Get the currently displayed PC Type
Acceptable
Response
%1
Unacceptable
“%1” [CR]
“Stand_by” ------------------------------------- Standby
“AV_Mode” ------------------------------------- AV Mode
Current Table such as “UXGA1” ---------- PC Mode
“Go_PC_adj.” --------------------------------- Auto
“No_signal” ------------------------------------ No signal
“?” [CR]
20/24
PLC-XF70 Basic Serial Command Functional Specifications
7.10
Status 2 Read Command
COMMAND
Detail
“CRA” [CR]
Get the operating status of Video mute.
Acceptable
Response
%1
“%1” [CR]
Return a hex digit of 1 byte as two columns of character string.
Define each bit as eight bits by a hex digit as follows.
**** ****
|||| |||└ bit0:Shutter Close = 1 / Open = 0
|||| ||└― bit1:Spare
|||| |└―― bit2:Spare
|||| └――― bit3:Spare
|||└――――― bit4:Spare
||└―――――― bit5:Spare
|└――――――― bit6:Spare
└――――――――bit7:No signal=1, signal=0
ex:
Normal Operation: “00”
Shutter Close: “01”
No signal: “80”
When it is in Standby mode or Cooling Down process, it returns
“FF” even if the status is above.
Unacceptable
“?” [CR]
21/24
PLC-XF70 Basic Serial Command Functional Specifications
8
Command with Address Specification
8.1
Overview
- Commands with address are used to control more than one projector remotely through
RS-232C by a single computer.
- The command with address is defined as a single command per line that starts with ”A” and
ends with carriage return (0x0D).
- When a projector receives carriage return (0x0D), it starts decoding.
- The address such as “A001” is prefixed to the Basic Serial Command or Expand Serial
Command already mentioned.
e.g.) Functional Execution Command: “A001C05” [CR]
e.g.) Status Read Command: “A001CR0” [CR]
- Projector has the function to set up its own address in Service mode.
Initial setting is “No. 001”
Available range of the value is “001” to “999”
- It clears the data in the receive buffer under following conditions.
・
When receiving LF (0x0A) or EOF (0x1A).
・
When it takes more than one second to receive a single command.
(Until receiving a carriage return after the reception of the first data.)
- It returns the response within 60ms.
22/24
PLC-XF70 Basic Serial Command Functional Specifications
8.2
Functional Execution Command with address
8.2.1
1)
Format
PC issues a command in the format below:
“A” Address “C” Command [CR]
or
“C” Address “CF□” Command “□” Parameter [CR]
Address: 3-digit number (”001”-”999”)
Commands with “FFF” as the address are valid to all projectors.
Command: String (Refer to Basic and Expand Serial Commands)
2)
The only projector that have the address number matching with the one included in the
received data decodes the command, and when it gets ready to receive another command,
it returns the response.
[ACK] [CR]: When receiving Functional Execution Command (0x06, 0x0D)
“?” [CR]: When the received data cannot be decoded
However, when the address is “FFF”, the projector executes the function but does not
return any response.
8.2.2
When the command pipelining is needed
Functions which need command pipelining follow the rule below.
- Sending-side system issues commands every 100 ms
- When receiving an applicable command, the function is executed repeatedly for 120 ms .
- When receiving the same command in a row within 120 ms, the function is repeatedly
executed for another 120 ms from the moment.
- When there is no incoming command after 120 ms, the execution of pipelining is stopped.
- When the projector receives other command within 120 ms, the execution of pipelining is
stopped.
23/24
PLC-XF70 Basic Serial Command Functional Specifications
8.3
Status Read Command with Address
8.3.1 Format
1) PC issues a command in the format below:
“A” Address “CR” Command [CR]
or
“A” Address “CR□” Command [CR]
Address: 3-digit number (“001”-“999”)
Command: String (Refer to Basic and Expand Serial Commands)
2) The only projectors that have the address matching with the one in the received data
decode the command, and it returns required data.
Required Data [CR]
Required Data: String (Refer to Basic Status Read Command Table)
*When the received data cannot to be decoded, the projector returns “?” [CR].
24/24