FDA-160i - Brandywine Communications
FDA-160i
Advanced Distribution Amplifier
Features
•
Network Enabled Analog
•
Frequency Distribution Amplifier
•
•
Programmable per channel
amplitude
Dual Frequency Inputs with Auto
•
1U 19” rack mount
Failover
•
Redundant Hot Swap Power
Any Frequency from 1-20MHz
Supplies
The FDA-160i is a general-purpose frequency
distribution amplifier designed for use with
Brandywine high precision time and frequency
sources.
A 10/100 base T Ethernet interface provides full
control over the functionality of the system, including
reference selection and output amplitude (on a per
channel basis).
The FDA-160i is contained in a compact IU rackmount chassis. The FDA accepts two sets of inputs,
comprising the reference frequency (typically 120MHz) and status from the source. The FDA
provides automatic changeover should one of the online source inputs fail. Manual source select override
is available on the front panel, or through the
Ethernet interface.
User control of the unit is via a built-in Web Browser
with user-friendly graphical interface, or via SNMP for
system applications.
A variety of status indicators are located on the front
panel for instant visual feedback, together with
manual controls for source selection.
Applications for the FDA-160i include secure
communications systems, manufacturing facilities,
digital television broadcasting and any system
requiring highly reliable frequency outputs.
FDA-160i Specifications
Frequency Inputs
Status Output (Alarm)
Frequency
Amplitude & Impedance
Isolation
1 – 20 MHz
0.5-1Vrms, 50 Ω
Transformer coupled
Number of Inputs
Connector Type
Input Selection
2
BNC
Manual, Auto
Fault Inputs
Number of Inputs
Signal Type
Active Level
Action
Type
Alarm Function
Power
Redundancy
2
TTL
Selectable for active
high or low
Forces on-line
changeover
Dry relay form C contacts
Ethernet SNMP trap
Summary of all input/output
alarms (relay)
Individual input, output, power
(Ethernet)
Voltage
Power Consumption
Dual redundant
Single supply maintains complete
unit
90-240 VAC 50/60Hz (std)
18-36V DC Optional
36-72VDC Optional
<15W
Frequency Outputs
Number of Outputs
Frequency
Output Level
Connector Type
Harmonic Distortion
Cross Talk
Spurious
Additive Phase Noise@10MHz
TBD.
16
Same as Input
1-20 MHz
5dBm to +13dBm, shortcircuit proof
BNC
-40 dBc
-80 dBc
-80 dBc
Interface Type
Protocols
Connector
10/100 base T
HTTP, DHCP, IPV4
RJ45
Interface Type
Parameters
Connector
RS232
115200, N, 8, 1
DB9
Display
Display Type
Functions
Temperature
Operating
Storage
Product Safety
EMC
-10 to +55ºC non condensing
-40 to +85ºC
EN60950-1: 2006 +
A11-2009 +A1:2010 A12:2011
EN55022 Class A
EN50082-2
FCC Chapter 15 Class A
Ordering Information
Network Interface
Console Port
Environmental and Safety
16 bicolor LED
Output status, Ethernet
settings
Basic Unit Includes Dual AC Power Supplies
022050005
2 input, 16 output 1-20 MHz**
Power Options (order separately)
022060001
Substitute 18-36 DC power for AC
022060002
Substitute 36-72 DC power for AC
Related Product: FDU-160i:
022050001
2 i/p 10MHz, 16 output 10MHz
022050002
2 i/p 5MHz, 16 output 5MHz
022050003
2 i/p 1MHz, 16 output 1MHz
022050004
1ea i/p 5MHz,10MHz, 8 ea. o/p 5,10 MHz*
The FDA-160i may be used with many of Brandywine’s
precision frequency sources such as the RG 2111 for
distribution of precision frequency outputs.
RG 2111 part number 001-0230
* No Auto-switch applicable to 022050004
© Brandywine Communications 2014